								-- Juniper-DS1-MIB
							 | 
						||
| 
								 | 
							
								--
							 | 
						||
| 
								 | 
							
								-- Juniper Networks Enterprise MIB
							 | 
						||
| 
								 | 
							
								--   DS1/E1 MIB
							 | 
						||
| 
								 | 
							
								--
							 | 
						||
| 
								 | 
							
								-- Copyright (c) 1998, 1999 Redstone Communications, Inc.
							 | 
						||
| 
								 | 
							
								-- Copyright (c) 1999, 2002 Unisphere Networks, Inc.
							 | 
						||
| 
								 | 
							
								-- Copyright (c) 2002, 2003 Juniper Networks, Inc.
							 | 
						||
| 
								 | 
							
								--   All Rights Reserved.
							 | 
						||
| 
								 | 
							
								-- *****************************************************************************
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								Juniper-DS1-MIB  DEFINITIONS ::= BEGIN
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								IMPORTS
							 | 
						||
| 
								 | 
							
								    MODULE-IDENTITY, OBJECT-TYPE, Integer32
							 | 
						||
| 
								 | 
							
								        FROM SNMPv2-SMI
							 | 
						||
| 
								 | 
							
								    RowStatus, DisplayString
							 | 
						||
| 
								 | 
							
								        FROM SNMPv2-TC
							 | 
						||
| 
								 | 
							
								    MODULE-COMPLIANCE, OBJECT-GROUP
							 | 
						||
| 
								 | 
							
								        FROM SNMPv2-CONF
							 | 
						||
| 
								 | 
							
								    ifIndex, InterfaceIndexOrZero
							 | 
						||
| 
								 | 
							
								        FROM IF-MIB
							 | 
						||
| 
								 | 
							
								    juniMibs
							 | 
						||
| 
								 | 
							
								        FROM Juniper-MIBs
							 | 
						||
| 
								 | 
							
								    JuniTimeSlotMap, JuniNextIfIndex
							 | 
						||
| 
								 | 
							
								        FROM Juniper-TC;
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDs1MIB  MODULE-IDENTITY
							 | 
						||
| 
								 | 
							
								    LAST-UPDATED "200302101507Z"  -- 10-Feb-03 10:07 AM EST
							 | 
						||
| 
								 | 
							
								    ORGANIZATION "Juniper Networks, Inc."
							 | 
						||
| 
								 | 
							
								    CONTACT-INFO
							 | 
						||
| 
								 | 
							
								        "       Juniper Networks, Inc.
							 | 
						||
| 
								 | 
							
								        Postal: 10 Technology Park Drive
							 | 
						||
| 
								 | 
							
								                Westford, MA  01886-3146
							 | 
						||
| 
								 | 
							
								                USA
							 | 
						||
| 
								 | 
							
								        Tel:    +1 978 589 5800
							 | 
						||
| 
								 | 
							
								        Email:  mib@Juniper.net"
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "The DS1/E1 MIB for the Juniper enterprise.  This MIB contains managed
							 | 
						||
| 
								 | 
							
								        objects to supplement those found in RFC1406 DS1/E1 MIB."
							 | 
						||
| 
								 | 
							
								    -- Revision History
							 | 
						||
| 
								 | 
							
								    REVISION    "200302101507Z"  -- 10-Feb-03 10:07 AM EST  - JUNOSe 5.0
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Replaced Unisphere names with Juniper names."
							 | 
						||
| 
								 | 
							
								    REVISION    "200209121659Z"  -- 12-Sep-02 12:59 PM EDT  - JUNOSe 4.1
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Added support for FDL transmit mode, remote FDL strings and far end FDL
							 | 
						||
| 
								 | 
							
								        carrier."
							 | 
						||
| 
								 | 
							
								    REVISION    "200205131601Z"  -- 13-May-02 12:01 PM EDT  - JUNOSe 4.0
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Added support for FDL."
							 | 
						||
| 
								 | 
							
								    REVISION    "200107311825Z"  -- 31-Jul-01 02:25 PM EDT  - JUNOSe 3.2
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Change access on juniDsx1Ds1ChannelNumber."
							 | 
						||
| 
								 | 
							
								    REVISION    "200104041805Z"  -- 04-Apr-01 02:05 PM EDT  - JUNOSe 3.0
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Added dynamic DS1 interface support."
							 | 
						||
| 
								 | 
							
								    REVISION      "9906170000Z"  -- 17-Jun-99               - JUNOSe 1.1
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Updated version of this MIB module."
							 | 
						||
| 
								 | 
							
								    REVISION      "9811130000Z"  -- 13-Nov-98               - JUNOSe 1.0
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Initial version of this MIB module."
							 | 
						||
| 
								 | 
							
								    ::= { juniMibs 5 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
							 | 
						||
| 
								 | 
							
								-- Managed objects
							 | 
						||
| 
								 | 
							
								-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
							 | 
						||
| 
								 | 
							
								juniDs1Objects     OBJECT IDENTIFIER ::= { juniDs1MIB 1 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								-- /////////////////////////////////////////////////////////////////////////////
							 | 
						||
| 
								 | 
							
								--
							 | 
						||
| 
								 | 
							
								-- DS1 Interfaces
							 | 
						||
| 
								 | 
							
								--
							 | 
						||
| 
								 | 
							
								-- /////////////////////////////////////////////////////////////////////////////
							 | 
						||
| 
								 | 
							
								--
							 | 
						||
| 
								 | 
							
								-- The DS1 Configuration Table
							 | 
						||
| 
								 | 
							
								--
							 | 
						||
| 
								 | 
							
								juniDsx1ConfigTable  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      SEQUENCE OF JuniDsx1ConfigEntry
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  not-accessible
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This table contains entries for DS1/E1 interfaces present in the
							 | 
						||
| 
								 | 
							
								        system."
							 | 
						||
| 
								 | 
							
								    ::= { juniDs1Objects 1 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1ConfigEntry  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      JuniDsx1ConfigEntry
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  not-accessible
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Each entry describes the characteristics of an DS1/E1 interface."
							 | 
						||
| 
								 | 
							
								    INDEX     { ifIndex }
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigTable 1 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								JuniDsx1ConfigEntry ::= SEQUENCE {
							 | 
						||
| 
								 | 
							
								        juniDsx1TimeSlotMap              JuniTimeSlotMap,
							 | 
						||
| 
								 | 
							
								        juniDsx1Ds1ChannelNumber         Integer32,
							 | 
						||
| 
								 | 
							
								        juniDsx1Capabilities             Integer32,
							 | 
						||
| 
								 | 
							
								        juniDsx1Mode                     INTEGER,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineBuildOutCapabilities Integer32,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineBuildOutType         INTEGER,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineAttenuation          INTEGER,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineLength               Integer32,
							 | 
						||
| 
								 | 
							
								        juniDsx1LowerIfIndex             InterfaceIndexOrZero,
							 | 
						||
| 
								 | 
							
								        juniDsx1RowStatus                RowStatus,
							 | 
						||
| 
								 | 
							
								        juniDsx1SendCode                 INTEGER,
							 | 
						||
| 
								 | 
							
								        juniDsx1YellowAlarm              INTEGER,
							 | 
						||
| 
								 | 
							
								        juniDsx1RemoteLoopback           INTEGER,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlCarrier               INTEGER,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlEic                   DisplayString,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlLic                   DisplayString,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlFic                   DisplayString,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlUnit                  DisplayString,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlPfi                   DisplayString,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlPort                  DisplayString,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlGenerator             DisplayString,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlTransmit              BITS }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1TimeSlotMap  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      JuniTimeSlotMap
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "A bitmap representing the timeslots on the DS1/E1 interface that have
							 | 
						||
| 
								 | 
							
								        been allocated for service.
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								        For channelized DS1/E1, set bits reflect the union of timeslot
							 | 
						||
| 
								 | 
							
								        allocations across all fractional arrangements operating over this
							 | 
						||
| 
								 | 
							
								        DS1/E1 interface.
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								        For unchannelized DS1/E1, all relevant timeslot bits will be set."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 1 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1Ds1ChannelNumber  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      Integer32 (0..28)
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This variable represents the channel number of the DS1/E1 on its parent
							 | 
						||
| 
								 | 
							
								        DS3/E3.  A value of 0 indicates this DS1/E1 does not have a parent
							 | 
						||
| 
								 | 
							
								        DS3/E3."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 2 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1Capabilities  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      Integer32 (0..7)
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "A value which indicates the set of capabilities of the DS1/E1
							 | 
						||
| 
								 | 
							
								        interface.
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								        The value is a sum.  This sum initially takes the value zero.  Then, for
							 | 
						||
| 
								 | 
							
								        each capability, C, in the range 1 through 3, that this interface
							 | 
						||
| 
								 | 
							
								        supports, 2 raised to (C - 1) is added to the sum.  For example, an
							 | 
						||
| 
								 | 
							
								        interface which is only E1 capable would have a value of 2 (2^(2-1)).
							 | 
						||
| 
								 | 
							
								        In contrast, an interface which is both T1 and J1 capable would have a
							 | 
						||
| 
								 | 
							
								        value of 5 (2^(1-1) + 2^(3-1)).  The values for DS1/E1 interface
							 | 
						||
| 
								 | 
							
								        capabilities are as follows:
							 | 
						||
| 
								 | 
							
								            capability  function
							 | 
						||
| 
								 | 
							
								                1       T1
							 | 
						||
| 
								 | 
							
								                2       E1
							 | 
						||
| 
								 | 
							
								                3       J1 "
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 3 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1Mode  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      INTEGER {
							 | 
						||
| 
								 | 
							
								                    t1(1),
							 | 
						||
| 
								 | 
							
								                    e1(2),
							 | 
						||
| 
								 | 
							
								                    j1(3) }
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This variable represents the DS1/E1 interface mode.  The value of the
							 | 
						||
| 
								 | 
							
								        juniDsx1Capabilities object for the DS1/E1 interface indicates the valid
							 | 
						||
| 
								 | 
							
								        set of values for this object."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 4 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1LineBuildOutCapabilities  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      Integer32 (0..3)
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "A value which indicates the set of line build out capabilities of the
							 | 
						||
| 
								 | 
							
								        DS1/E1 interface.
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								        The value is a sum.  This sum initially takes the value zero.  Then, for
							 | 
						||
| 
								 | 
							
								        each line build out capability, C, in the range 1 or 2, that this
							 | 
						||
| 
								 | 
							
								        interface supports, 2 raised to (C - 1) is added to the sum.  For
							 | 
						||
| 
								 | 
							
								        example, an interface which is only short haul capable would have a
							 | 
						||
| 
								 | 
							
								        value of 2 (2^(2-1)).  In contrast, an interface which is both short
							 | 
						||
| 
								 | 
							
								        haul and long haul capable would have a value of 3 (2^(1-1) + 2^(2-1)).
							 | 
						||
| 
								 | 
							
								        The values for DS1/E1 interface line build out capabilities are as
							 | 
						||
| 
								 | 
							
								        follows:
							 | 
						||
| 
								 | 
							
								            line build out capability   function
							 | 
						||
| 
								 | 
							
								                1                       short haul
							 | 
						||
| 
								 | 
							
								                2                       long haul"
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 5 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1LineBuildOutType  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      INTEGER {
							 | 
						||
| 
								 | 
							
								                    shortHaul(1),
							 | 
						||
| 
								 | 
							
								                    longHaul(2),
							 | 
						||
| 
								 | 
							
								                    notSupported(3) }
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This variable represents the configured line build out type of the
							 | 
						||
| 
								 | 
							
								        DS1/E1 interface.  The value of the juniDsx1LineBuildOutCapabilities
							 | 
						||
| 
								 | 
							
								        object for the DS1/E1 interface indicates the valid set of values for
							 | 
						||
| 
								 | 
							
								        this object."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 6 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1LineAttenuation  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      INTEGER {
							 | 
						||
| 
								 | 
							
								                    db0(1),
							 | 
						||
| 
								 | 
							
								                    dbMinus7Point5(2),
							 | 
						||
| 
								 | 
							
								                    dbMinus15(3),
							 | 
						||
| 
								 | 
							
								                    dbMinus22Point5(4),
							 | 
						||
| 
								 | 
							
								                    notSupported(5) }
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This variable represents the configured line attenuation of the DS1/E1
							 | 
						||
| 
								 | 
							
								        interface.  Note that the value of this object only takes effect when
							 | 
						||
| 
								 | 
							
								        the value of the juniDsx1LineBuildOutType for the DS1/E1 interface is
							 | 
						||
| 
								 | 
							
								        set to longHaul(2)."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 7 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1LineLength  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      Integer32 (0..64000)
							 | 
						||
| 
								 | 
							
								    UNITS       "meters"
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This variable represents the length of the DS1/E1 line in meters.  Note
							 | 
						||
| 
								 | 
							
								        that the value of this object only takes effect when the value of the
							 | 
						||
| 
								 | 
							
								        juniDsx1LineBuildOutType for the DS1/E1 interface is set to
							 | 
						||
| 
								 | 
							
								        shortHaul(1)."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 8 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1LowerIfIndex  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      InterfaceIndexOrZero
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "The ifIndex of the interface over which this Dsx1 interface is to be
							 | 
						||
| 
								 | 
							
								        layered.  A value of zero indicates no layering.  An implementation may
							 | 
						||
| 
								 | 
							
								        choose to require that a nonzero value be configured at entry creation."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 9 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1RowStatus  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      RowStatus
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Controls creation/deletion of entries in this table according to the
							 | 
						||
| 
								 | 
							
								        RowStatus textual convention, constrained to support the following
							 | 
						||
| 
								 | 
							
								        values only:
							 | 
						||
| 
								 | 
							
								            createAndGo
							 | 
						||
| 
								 | 
							
								            destroy
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								        To create an entry in this table, the following entry objects MUST be
							 | 
						||
| 
								 | 
							
								        explicitly configured:
							 | 
						||
| 
								 | 
							
								            juniDsx1RowStatus
							 | 
						||
| 
								 | 
							
								            juniDsx1LowerIfIndex
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								        In addition, when creating an entry the following conditions must hold:
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								            A value for ifIndex must have been determined previously, by reading
							 | 
						||
| 
								 | 
							
								            juniDsx1NextIfIndex.
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								            The interface identified by juniDsx1hLowerIfIndex must exist.
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								        A corresponding entry in ifTable/ifXTable/juniIfTable is created/
							 | 
						||
| 
								 | 
							
								        destroyed as a result of creating/destroying an entry in this table."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 10 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1SendCode  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      INTEGER {
							 | 
						||
| 
								 | 
							
								                    sendInbandLineCode(1),
							 | 
						||
| 
								 | 
							
								                    sendBellcoreLineCode(2),
							 | 
						||
| 
								 | 
							
								                    sendBellcoreInbandLineCode(3),
							 | 
						||
| 
								 | 
							
								                    sendQRSPattern(4),
							 | 
						||
| 
								 | 
							
								                    sendAllZerosPattern(5),
							 | 
						||
| 
								 | 
							
								                    sendAllOnesPattern(6),
							 | 
						||
| 
								 | 
							
								                    sendAltZeroOnePattern(7),
							 | 
						||
| 
								 | 
							
								                    sendTwo11Pattern(8),
							 | 
						||
| 
								 | 
							
								                    sendTwo15Pattern(9),
							 | 
						||
| 
								 | 
							
								                    sendTwo20Pattern(10),
							 | 
						||
| 
								 | 
							
								                    sendTwo23Pattern(11),
							 | 
						||
| 
								 | 
							
								                    sendUnfrQRSPattern(12),
							 | 
						||
| 
								 | 
							
								                    sendUnfrAllZerosPattern(13),
							 | 
						||
| 
								 | 
							
								                    sendUnfrAllOnesPattern(14),
							 | 
						||
| 
								 | 
							
								                    sendUnfrAltZeroOnePattern(15),
							 | 
						||
| 
								 | 
							
								                    sendUnfrTwo11Pattern(16),
							 | 
						||
| 
								 | 
							
								                    sendUnfrTwo15Pattern(17),
							 | 
						||
| 
								 | 
							
								                    sendUnfrTwo20Pattern(18),
							 | 
						||
| 
								 | 
							
								                    sendUnfrTwo23Pattern(19),
							 | 
						||
| 
								 | 
							
								                    otherPattern(20) }
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This variable indicates what type of code is being sent across the DS1
							 | 
						||
| 
								 | 
							
								        interface by the device."
							 | 
						||
| 
								 | 
							
								    DEFVAL    { otherPattern }
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 11 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1YellowAlarm  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      INTEGER {
							 | 
						||
| 
								 | 
							
								                    generate(1),
							 | 
						||
| 
								 | 
							
								                    detect(2),
							 | 
						||
| 
								 | 
							
								                    generateAndDetect(3),
							 | 
						||
| 
								 | 
							
								                    none(4) }
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This bitmap indicates the yellow alarm settings, and is the sum of the
							 | 
						||
| 
								 | 
							
								        capabilities."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 12 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1RemoteLoopback  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      INTEGER {
							 | 
						||
| 
								 | 
							
								                    disabled(0),
							 | 
						||
| 
								 | 
							
								                    enabled(1) }
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This variable indicates the remote loopback setting."
							 | 
						||
| 
								 | 
							
								    DEFVAL    { disabled }
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 13 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FdlCarrier  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      INTEGER {
							 | 
						||
| 
								 | 
							
								                    disabled(0),
							 | 
						||
| 
								 | 
							
								                    enabled(1) }
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Specifies the interface is used in carrier environment."
							 | 
						||
| 
								 | 
							
								    DEFVAL    { disabled }
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 14 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FdlEic  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE(0..10))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This is the equipment identification code."
							 | 
						||
| 
								 | 
							
								    DEFVAL    { "" }
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 15 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FdlLic  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE(0..11))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This is the location identification code."
							 | 
						||
| 
								 | 
							
								    DEFVAL    { "" }
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 16 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FdlFic  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE(0..10))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This is the frame identification code."
							 | 
						||
| 
								 | 
							
								    DEFVAL    { "" }
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 17 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FdlUnit  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE(0..6))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This is the unit identification code."
							 | 
						||
| 
								 | 
							
								    DEFVAL    { "" }
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 18 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FdlPfi  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE(0..38))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This is the facility identification code."
							 | 
						||
| 
								 | 
							
								    DEFVAL    { "" }
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 19 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FdlPort  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE(0..4))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This is the equipment port number."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 20 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FdlGenerator  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE(0..38))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This is the generator number."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 21 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FdlTransmit  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      BITS {
							 | 
						||
| 
								 | 
							
								                    path(0),
							 | 
						||
| 
								 | 
							
								                    idlesignal(1),
							 | 
						||
| 
								 | 
							
								                    testsignal(2) }
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-create
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Specifies transmission enabling.
							 | 
						||
| 
								 | 
							
								            path       - Bit 0 for path transmit.  When this bit is set
							 | 
						||
| 
								 | 
							
								                         indicates path transmit is enabled; otherwise
							 | 
						||
| 
								 | 
							
								                         path transmit disabled.
							 | 
						||
| 
								 | 
							
								            idlesignal - Bit 1 for idlesignal transmit.  When this bit
							 | 
						||
| 
								 | 
							
								                         is set idlesingal transmit is enabled; otherwise
							 | 
						||
| 
								 | 
							
								                         idlesignal transmit disabled.
							 | 
						||
| 
								 | 
							
								            testsignal - Bit 2 for testsignal transmit.  When this bit
							 | 
						||
| 
								 | 
							
								                         is set testsignal transmit is enabled; otherwise
							 | 
						||
| 
								 | 
							
								                         testsignal transmit disabled.
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								        The value of this object defaults to zero, indicating that none of FDL
							 | 
						||
| 
								 | 
							
								        transmit methods are enabled."
							 | 
						||
| 
								 | 
							
								    DEFVAL    { { } }
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1ConfigEntry 22 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDs1NextIfIndex  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      JuniNextIfIndex
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Coordinate ifIndex value allocation for entries in juniDsx1ConfigTable.
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								        A GET of this object returns the next available ifIndex value to be used
							 | 
						||
| 
								 | 
							
								        to create an entry in the associated interface table; or zero, if no
							 | 
						||
| 
								 | 
							
								        valid ifIndex value is available.  This object also returns a value of
							 | 
						||
| 
								 | 
							
								        zero when it is the lexicographic successor of a varbind presented in an
							 | 
						||
| 
								 | 
							
								        SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
							 | 
						||
| 
								 | 
							
								        that ifIndex allocation is unintended.
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								        Successive GETs will typically return different values, thus avoiding
							 | 
						||
| 
								 | 
							
								        collisions among cooperating management clients seeking to create table
							 | 
						||
| 
								 | 
							
								        entries simultaneously."
							 | 
						||
| 
								 | 
							
								    ::= { juniDs1Objects 2 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								--
							 | 
						||
| 
								 | 
							
								-- The DS1 Far End Configuration Table contains
							 | 
						||
| 
								 | 
							
								-- configuration information reported from the remote end.
							 | 
						||
| 
								 | 
							
								--
							 | 
						||
| 
								 | 
							
								juniDsx1FarEndConfigTable  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      SEQUENCE OF JuniDsx1FarEndConfigEntry
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  not-accessible
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "The DS1 Far End Configuration table."
							 | 
						||
| 
								 | 
							
								    ::= { juniDs1Objects 3 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FarEndConfigEntry  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      JuniDsx1FarEndConfigEntry
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  not-accessible
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "An entry in the DS1 Far End Configuration table."
							 | 
						||
| 
								 | 
							
								    INDEX     { juniDsx1FarEndLineIndex }
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1FarEndConfigTable 1 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								JuniDsx1FarEndConfigEntry ::= SEQUENCE {
							 | 
						||
| 
								 | 
							
								        juniDsx1FarEndLineIndex         INTEGER,
							 | 
						||
| 
								 | 
							
								        juniDsx1FarEndEquipCode         DisplayString,
							 | 
						||
| 
								 | 
							
								        juniDsx1FarEndLocationIDCode    DisplayString,
							 | 
						||
| 
								 | 
							
								        juniDsx1FarEndFrameIDCode       DisplayString,
							 | 
						||
| 
								 | 
							
								        juniDsx1FarEndUnitCode          DisplayString,
							 | 
						||
| 
								 | 
							
								        juniDsx1FarEndFacilityIDCode    DisplayString,
							 | 
						||
| 
								 | 
							
								        juniDsx1FarEndPortNumber        DisplayString,
							 | 
						||
| 
								 | 
							
								        juniDsx1FarEndGeneratorNumber   DisplayString,
							 | 
						||
| 
								 | 
							
								        juniDsx1FarEndCarrier           INTEGER }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FarEndLineIndex  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      INTEGER (1..'7fffffff'h)
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  not-accessible
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "The index value which uniquely identifies the DS1 interface to which
							 | 
						||
| 
								 | 
							
								        this entry is applicable.  The interface identified by a particular
							 | 
						||
| 
								 | 
							
								        value of this index is the same interface as identified by the same
							 | 
						||
| 
								 | 
							
								        value a dsx1LineIndex object instance."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1FarEndConfigEntry 1 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FarEndEquipCode  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE (0..10))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This is the Far End Equipment Identification code that describes the
							 | 
						||
| 
								 | 
							
								        specific piece of equipment.  It is sent within the Path Identification
							 | 
						||
| 
								 | 
							
								        Message."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1FarEndConfigEntry 2 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FarEndLocationIDCode  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE (0..11))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This is the Far End Location Identification code that describes the
							 | 
						||
| 
								 | 
							
								        specific location of the equipment.  It is sent within the Path
							 | 
						||
| 
								 | 
							
								        Identification Message."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1FarEndConfigEntry 3 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FarEndFrameIDCode  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE (0..10))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This is the Far End Frame Identification code that identifies where the
							 | 
						||
| 
								 | 
							
								        equipment is located within a building at a given location.  It is sent
							 | 
						||
| 
								 | 
							
								        within the Path Identification Message."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1FarEndConfigEntry 4 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FarEndUnitCode  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE (0..6))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This is the Far End code that identifies the equipment location within
							 | 
						||
| 
								 | 
							
								        a bay.  It is sent within the Path Identification Message."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1FarEndConfigEntry 5 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FarEndFacilityIDCode  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE (0..38))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This code identifies a specific Far End DS1 path.  It is sent within
							 | 
						||
| 
								 | 
							
								        the Path Identification Message."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1FarEndConfigEntry 6 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FarEndPortNumber  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE (0..4))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This code identifies the port number of the Far End DS1.  It is sent
							 | 
						||
| 
								 | 
							
								        within the Idle Signal Message."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1FarEndConfigEntry 7 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FarEndGeneratorNumber  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE (0..38))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This code identifies the Far End DS1 Generator Number.  It is sent
							 | 
						||
| 
								 | 
							
								        within the Test Signal Message."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1FarEndConfigEntry 8 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDsx1FarEndCarrier  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      INTEGER {
							 | 
						||
| 
								 | 
							
								                    disabled(0),
							 | 
						||
| 
								 | 
							
								                    enabled(1) }
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Specifies the interface is used in carrier environment.  It is sent
							 | 
						||
| 
								 | 
							
								        with all FDL messages."
							 | 
						||
| 
								 | 
							
								    ::= { juniDsx1FarEndConfigEntry 9 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
							 | 
						||
| 
								 | 
							
								-- Notifications
							 | 
						||
| 
								 | 
							
								-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
							 | 
						||
| 
								 | 
							
								-- No notifications are defined in this MIB.  Placeholders follow.
							 | 
						||
| 
								 | 
							
								-- juniDs1TrapControl      OBJECT IDENTIFIER ::= { juniDs1MIB 2 }
							 | 
						||
| 
								 | 
							
								-- juniDs1Traps            OBJECT IDENTIFIER ::= { juniDs1MIB 3 }
							 | 
						||
| 
								 | 
							
								-- juniDs1TrapPrefix       OBJECT IDENTIFIER ::= { juniDs1Traps 0 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
							 | 
						||
| 
								 | 
							
								-- Conformance information
							 | 
						||
| 
								 | 
							
								-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
							 | 
						||
| 
								 | 
							
								juniDs1Conformance OBJECT IDENTIFIER ::= { juniDs1MIB 4 }
							 | 
						||
| 
								 | 
							
								juniDs1Compliances OBJECT IDENTIFIER ::= { juniDs1Conformance 1 }
							 | 
						||
| 
								 | 
							
								juniDs1Groups      OBJECT IDENTIFIER ::= { juniDs1Conformance 2 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								--
							 | 
						||
| 
								 | 
							
								-- compliance statements
							 | 
						||
| 
								 | 
							
								--
							 | 
						||
| 
								 | 
							
								juniDs1Compliance  MODULE-COMPLIANCE
							 | 
						||
| 
								 | 
							
								    STATUS      obsolete
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Obsolete compliance statement for entities which implement the Juniper
							 | 
						||
| 
								 | 
							
								        DS1/E1 MIB.  This statement became obsolete when new objects were
							 | 
						||
| 
								 | 
							
								        added."
							 | 
						||
| 
								 | 
							
								    MODULE   -- this module
							 | 
						||
| 
								 | 
							
								        MANDATORY-GROUPS {
							 | 
						||
| 
								 | 
							
								            juniDs1Group }
							 | 
						||
| 
								 | 
							
								    ::= { juniDs1Compliances 1 }                                   -- JUNOSe 1.0
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDs1Compliance2  MODULE-COMPLIANCE
							 | 
						||
| 
								 | 
							
								    STATUS      obsolete
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Obsolete compliance statement for entities which implement the Juniper
							 | 
						||
| 
								 | 
							
								        DS1/E1 MIB.  This statement became obsolete when dynamic DS1 interface
							 | 
						||
| 
								 | 
							
								        support was added."
							 | 
						||
| 
								 | 
							
								    MODULE   -- this module
							 | 
						||
| 
								 | 
							
								        MANDATORY-GROUPS {
							 | 
						||
| 
								 | 
							
								            juniDs1Group2 }
							 | 
						||
| 
								 | 
							
								    ::= { juniDs1Compliances 2 }                                   -- JUNOSe 1.1
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDs1Compliance3  MODULE-COMPLIANCE
							 | 
						||
| 
								 | 
							
								    STATUS      obsolete
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Obsolete compliance statement for entities which implement the Juniper
							 | 
						||
| 
								 | 
							
								        DS1/E1 MIB.  This statement became obsolete when FDL support was added."
							 | 
						||
| 
								 | 
							
								    MODULE   -- this module
							 | 
						||
| 
								 | 
							
								        MANDATORY-GROUPS {
							 | 
						||
| 
								 | 
							
								            juniDs1Group3 }
							 | 
						||
| 
								 | 
							
								    ::= { juniDs1Compliances 3 }                                   -- JUNOSe 3.0
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDs1Compliance4  MODULE-COMPLIANCE
							 | 
						||
| 
								 | 
							
								    STATUS      obsolete
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Obsolete compliance statement for entities which implement the Juniper
							 | 
						||
| 
								 | 
							
								        DS1/E1 MIB. This statement became obsolete when support for remote FDL
							 | 
						||
| 
								 | 
							
								        strings and FDL transmit mode was added."
							 | 
						||
| 
								 | 
							
								    MODULE   -- this module
							 | 
						||
| 
								 | 
							
								        MANDATORY-GROUPS {
							 | 
						||
| 
								 | 
							
								            juniDs1Group4 }
							 | 
						||
| 
								 | 
							
								    ::= { juniDs1Compliances 4 }                                   -- JUNOSe 4.0
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDs1Compliance5  MODULE-COMPLIANCE
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "The compliance statement for entities which implement the Juniper
							 | 
						||
| 
								 | 
							
								        DS1/E1 MIB."
							 | 
						||
| 
								 | 
							
								    MODULE   -- this module
							 | 
						||
| 
								 | 
							
								        MANDATORY-GROUPS {
							 | 
						||
| 
								 | 
							
								            juniDs1Group5 }
							 | 
						||
| 
								 | 
							
								    ::= { juniDs1Compliances 5 }                                   -- JUNOSe 4.1
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								--
							 | 
						||
| 
								 | 
							
								-- units of conformance
							 | 
						||
| 
								 | 
							
								--
							 | 
						||
| 
								 | 
							
								juniDs1Group  OBJECT-GROUP
							 | 
						||
| 
								 | 
							
								    OBJECTS {
							 | 
						||
| 
								 | 
							
								        juniDsx1TimeSlotMap,
							 | 
						||
| 
								 | 
							
								        juniDsx1Ds1ChannelNumber }
							 | 
						||
| 
								 | 
							
								    STATUS      obsolete
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Obsolete collection of objects providing management of DS1/E1
							 | 
						||
| 
								 | 
							
								        interfaces in a Juniper product.  This group became obsolete when new
							 | 
						||
| 
								 | 
							
								        objects where added to the MIB."
							 | 
						||
| 
								 | 
							
								    ::= { juniDs1Groups 1 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDs1Group2  OBJECT-GROUP
							 | 
						||
| 
								 | 
							
								    OBJECTS {
							 | 
						||
| 
								 | 
							
								        juniDsx1TimeSlotMap,
							 | 
						||
| 
								 | 
							
								        juniDsx1Ds1ChannelNumber,
							 | 
						||
| 
								 | 
							
								        juniDsx1Capabilities,
							 | 
						||
| 
								 | 
							
								        juniDsx1Mode,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineBuildOutCapabilities,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineBuildOutType,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineAttenuation,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineLength }
							 | 
						||
| 
								 | 
							
								    STATUS      obsolete
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Obsolete collection of objects providing management of DS1/E1
							 | 
						||
| 
								 | 
							
								        interfaces in a Juniper product.  This group became obsolete when
							 | 
						||
| 
								 | 
							
								        dynamic DS1 interface support was added."
							 | 
						||
| 
								 | 
							
								    ::= { juniDs1Groups 2 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDs1Group3  OBJECT-GROUP
							 | 
						||
| 
								 | 
							
								    OBJECTS {
							 | 
						||
| 
								 | 
							
								        juniDsx1TimeSlotMap,
							 | 
						||
| 
								 | 
							
								        juniDsx1Ds1ChannelNumber,
							 | 
						||
| 
								 | 
							
								        juniDsx1Capabilities,
							 | 
						||
| 
								 | 
							
								        juniDsx1Mode,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineBuildOutCapabilities,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineBuildOutType,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineAttenuation,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineLength,
							 | 
						||
| 
								 | 
							
								        juniDsx1LowerIfIndex,
							 | 
						||
| 
								 | 
							
								        juniDsx1RowStatus,
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								        juniDs1NextIfIndex }
							 | 
						||
| 
								 | 
							
								    STATUS      obsolete
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Obsolete collection of objects providing management of DS1/E1
							 | 
						||
| 
								 | 
							
								        interfaces in a Juniper product.  This group became obsolete when FDL
							 | 
						||
| 
								 | 
							
								        support was added."
							 | 
						||
| 
								 | 
							
								    ::= { juniDs1Groups 3 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDs1Group4  OBJECT-GROUP
							 | 
						||
| 
								 | 
							
								    OBJECTS {
							 | 
						||
| 
								 | 
							
								        juniDsx1TimeSlotMap,
							 | 
						||
| 
								 | 
							
								        juniDsx1Ds1ChannelNumber,
							 | 
						||
| 
								 | 
							
								        juniDsx1Capabilities,
							 | 
						||
| 
								 | 
							
								        juniDsx1Mode,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineBuildOutCapabilities,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineBuildOutType,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineAttenuation,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineLength,
							 | 
						||
| 
								 | 
							
								        juniDsx1LowerIfIndex,
							 | 
						||
| 
								 | 
							
								        juniDsx1RowStatus,
							 | 
						||
| 
								 | 
							
								        juniDsx1SendCode,
							 | 
						||
| 
								 | 
							
								        juniDsx1YellowAlarm,
							 | 
						||
| 
								 | 
							
								        juniDsx1RemoteLoopback,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlCarrier,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlEic,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlLic,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlFic,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlUnit,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlPfi,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlPort,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlGenerator,
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								        juniDs1NextIfIndex }
							 | 
						||
| 
								 | 
							
								    STATUS      obsolete
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Obsolete collection of objects providing management of DS1/E1
							 | 
						||
| 
								 | 
							
								        interfaces in a Juniper product.  This group became obsolete when
							 | 
						||
| 
								 | 
							
								        support for remote FDL strings and FDL transmit mode was added."
							 | 
						||
| 
								 | 
							
								    ::= { juniDs1Groups 4 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								juniDs1Group5  OBJECT-GROUP
							 | 
						||
| 
								 | 
							
								    OBJECTS {
							 | 
						||
| 
								 | 
							
								        juniDsx1TimeSlotMap,
							 | 
						||
| 
								 | 
							
								        juniDsx1Ds1ChannelNumber,
							 | 
						||
| 
								 | 
							
								        juniDsx1Capabilities,
							 | 
						||
| 
								 | 
							
								        juniDsx1Mode,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineBuildOutCapabilities,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineBuildOutType,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineAttenuation,
							 | 
						||
| 
								 | 
							
								        juniDsx1LineLength,
							 | 
						||
| 
								 | 
							
								        juniDsx1LowerIfIndex,
							 | 
						||
| 
								 | 
							
								        juniDsx1RowStatus,
							 | 
						||
| 
								 | 
							
								        juniDsx1SendCode,
							 | 
						||
| 
								 | 
							
								        juniDsx1YellowAlarm,
							 | 
						||
| 
								 | 
							
								        juniDsx1RemoteLoopback,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlCarrier,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlEic,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlLic,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlFic,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlUnit,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlPfi,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlPort,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlGenerator,
							 | 
						||
| 
								 | 
							
								        juniDsx1FdlTransmit,
							 | 
						||
| 
								 | 
							
								        juniDsx1FarEndEquipCode,
							 | 
						||
| 
								 | 
							
								        juniDsx1FarEndLocationIDCode,
							 | 
						||
| 
								 | 
							
								        juniDsx1FarEndFrameIDCode,
							 | 
						||
| 
								 | 
							
								        juniDsx1FarEndUnitCode,
							 | 
						||
| 
								 | 
							
								        juniDsx1FarEndFacilityIDCode,
							 | 
						||
| 
								 | 
							
								        juniDsx1FarEndPortNumber,
							 | 
						||
| 
								 | 
							
								        juniDsx1FarEndGeneratorNumber,
							 | 
						||
| 
								 | 
							
								        juniDsx1FarEndCarrier,
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								        juniDs1NextIfIndex }
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "A collection of objects providing management of DS1/E1 interfaces in a
							 | 
						||
| 
								 | 
							
								        Juniper product."
							 | 
						||
| 
								 | 
							
								    ::= { juniDs1Groups 5 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								END
							 |