								-- Accedian Enterprise Specific MIB: Structure of Management Information
							 | 
						||
| 
								 | 
							
								--
							 | 
						||
| 
								 | 
							
								-- Copyright (c) 2005-2011, Accedian Networks, Inc.
							 | 
						||
| 
								 | 
							
								-- All rights reserved.
							 | 
						||
| 
								 | 
							
								--
							 | 
						||
| 
								 | 
							
								-- The contents of this document are subject to change without notice.
							 | 
						||
| 
								 | 
							
								--
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								ACD-ALARM-MIB DEFINITIONS ::= BEGIN
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								IMPORTS
							 | 
						||
| 
								 | 
							
								    MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
							 | 
						||
| 
								 | 
							
								    Unsigned32
							 | 
						||
| 
								 | 
							
								        FROM SNMPv2-SMI
							 | 
						||
| 
								 | 
							
								    DisplayString, TruthValue, DateAndTime
							 | 
						||
| 
								 | 
							
								        FROM SNMPv2-TC
							 | 
						||
| 
								 | 
							
								    MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
							 | 
						||
| 
								 | 
							
								        FROM SNMPv2-CONF
							 | 
						||
| 
								 | 
							
								    sysName
							 | 
						||
| 
								 | 
							
								        FROM SNMPv2-MIB
							 | 
						||
| 
								 | 
							
								    acdMibs
							 | 
						||
| 
								 | 
							
								        FROM ACCEDIAN-SMI;
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarm MODULE-IDENTITY
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								    LAST-UPDATED "201110100100Z"
							 | 
						||
| 
								 | 
							
								    ORGANIZATION "Accedian Networks, Inc."
							 | 
						||
| 
								 | 
							
								    CONTACT-INFO
							 | 
						||
| 
								 | 
							
								            "Accedian Technical Assistance Center
							 | 
						||
| 
								 | 
							
								             Accedian Networks, Inc.
							 | 
						||
| 
								 | 
							
								             4878 Levy, suite 202
							 | 
						||
| 
								 | 
							
								             Saint-Laurent, Quebec Canada H4R 2P1
							 | 
						||
| 
								 | 
							
								             E-mail: support@accedian.com"
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								            "The alarm Table for this Accedian Networks device."
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								    REVISION "201110100100Z"        -- 10 October 2011
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								            "Add acdAlarmCfgTableLastChangeTid and
							 | 
						||
| 
								 | 
							
								             acdAlarmStatusTableLastChangeTid."
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								    REVISION "201011100100Z"        -- 10 November 2010
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								            "Fix compliance section."
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								    REVISION "200902040100Z"        -- 4 Feb 2009
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								            "Add new fields in acdAlarmCfgEntry, acdAlarmActiveState and
							 | 
						||
| 
								 | 
							
								             acdAlarmClearState."
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								    REVISION "200802010100Z"        -- 1 Feb 2008
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								            "Add UNITS clause to object, where appropriate."
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								    REVISION "200705220100Z"        -- 22 May 2007
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								            "Add acdAlarmCfgNumber object to Alarm traps."
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								    REVISION "200612190100Z"        -- 19 Dec 2006
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								            "Add 802.3AH notification enable and msg field in status table."
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								    REVISION "200608060100Z"        -- 6 Aug 2006
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								            "Initial version of MIB module ACD-ALARM-MIB."
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								    ::= { acdMibs 1 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmMIBObjects      OBJECT IDENTIFIER ::= { acdAlarm 15 }
							 | 
						||
| 
								 | 
							
								acdAlarmConfig          OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 1 }
							 | 
						||
| 
								 | 
							
								acdAlarmStatus          OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 2 }
							 | 
						||
| 
								 | 
							
								acdAlarmConformance     OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 3 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmTableTid        OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 4 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								---------------------------------------------------------------------------
							 | 
						||
| 
								 | 
							
								 -- Alarm General configuration
							 | 
						||
| 
								 | 
							
								---------------------------------------------------------------------------
							 | 
						||
| 
								 | 
							
								acdAlarmGenThreshOn OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      Unsigned32 (500..50000)
							 | 
						||
| 
								 | 
							
								    UNITS       "milliseconds"
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-write
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "This value represents the Alarm On Hysteris. This is the time since the
							 | 
						||
| 
								 | 
							
								        detection of the On event inside the system versus the report. This is
							 | 
						||
| 
								 | 
							
								        to avoid storm of notifications."
							 | 
						||
| 
								 | 
							
								   ::= { acdAlarm 1 }
							 | 
						||
| 
								 | 
							
								 
							 | 
						||
| 
								 | 
							
								acdAlarmGenThreshOff OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      Unsigned32 (500..50000)
							 | 
						||
| 
								 | 
							
								    UNITS       "milliseconds"
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-write
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "This value represents the Alarm Off Hysteris. This is the time since the
							 | 
						||
| 
								 | 
							
								        detection of the Off event inside the system versus the report. This is
							 | 
						||
| 
								 | 
							
								        to avoid storm of notifications."
							 | 
						||
| 
								 | 
							
								   ::= { acdAlarm 2 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmGenLedEnable  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      TruthValue
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-write
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "This is to Enable the alarms reporting through the LEDs."
							 | 
						||
| 
								 | 
							
								   ::= { acdAlarm 3 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmGenSyslogEnable  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      TruthValue
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-write
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "This is to Enable the alarms reporting through the syslog system."
							 | 
						||
| 
								 | 
							
								   ::= { acdAlarm 4 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmGenSNMPEnable  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      TruthValue
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-write
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "This is to Enable the alarms reporting through the SNMP agent."
							 | 
						||
| 
								 | 
							
								   ::= { acdAlarm 5 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmGen8023AHEnable  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      TruthValue
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-write
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "This is to Enable the alarms reporting through the 802.3AH protocol."
							 | 
						||
| 
								 | 
							
								   ::= { acdAlarm 6 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								---------------------------------------------------------------------------
							 | 
						||
| 
								 | 
							
								 -- The Alarm configuration table
							 | 
						||
| 
								 | 
							
								 -- This table contains the configuration for each alarm.
							 | 
						||
| 
								 | 
							
								---------------------------------------------------------------------------
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmCfgTable OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      SEQUENCE OF AcdAlarmCfgEntry
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  not-accessible
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Table of all alarms."
							 | 
						||
| 
								 | 
							
								    ::= { acdAlarm 10 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmCfgEntry OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      AcdAlarmCfgEntry
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  not-accessible
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "An alarm is an exceptional event that requires user notificaton."
							 | 
						||
| 
								 | 
							
								    INDEX   { acdAlarmCfgID }
							 | 
						||
| 
								 | 
							
								    ::=  { acdAlarmCfgTable 1 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								AcdAlarmCfgEntry ::= SEQUENCE {
							 | 
						||
| 
								 | 
							
								    acdAlarmCfgID                   Unsigned32,
							 | 
						||
| 
								 | 
							
								    acdAlarmCfgNumber               Unsigned32,
							 | 
						||
| 
								 | 
							
								    acdAlarmCfgDesc                 DisplayString,
							 | 
						||
| 
								 | 
							
								    acdAlarmCfgEnable               TruthValue,
							 | 
						||
| 
								 | 
							
								    acdAlarmCfgSeverity             INTEGER,
							 | 
						||
| 
								 | 
							
								    acdAlarmCfgServiceAffecting     TruthValue,
							 | 
						||
| 
								 | 
							
								    acdAlarmCfgExtNumber            DisplayString,
							 | 
						||
| 
								 | 
							
								    acdAlarmCfgConditionType        DisplayString,
							 | 
						||
| 
								 | 
							
								    acdAlarmCfgAMOType              DisplayString
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								}
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmCfgID  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      Unsigned32
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "Unique value for each alarm. Its value ranges from 1 to
							 | 
						||
| 
								 | 
							
								    MAXINT (4 bytes). "
							 | 
						||
| 
								 | 
							
								   ::= { acdAlarmCfgEntry 1 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmCfgNumber  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      Unsigned32
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "Unique number that identifies this alarm. Assigned by the unit. The
							 | 
						||
| 
								 | 
							
								        alarm identifier is compose of 3 fields, the module number, the instance
							 | 
						||
| 
								 | 
							
								        number and the error number. The alarm number looks like this:
							 | 
						||
| 
								 | 
							
								        A.BBB.CC and is expressed in decimal, A is the module number, BBB is
							 | 
						||
| 
								 | 
							
								        the instance number (1-999) and CC is the error number (1-99). A module
							 | 
						||
| 
								 | 
							
								        number is assigned for each source of alarm in the system. For example
							 | 
						||
| 
								 | 
							
								        the port module is set to 1, the SFP module is set to 2, the PAA is set
							 | 
						||
| 
								 | 
							
								        to 3 and the environmental is set to 8."
							 | 
						||
| 
								 | 
							
								   ::= { acdAlarmCfgEntry 2 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmCfgDesc  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE (0..128))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-write
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "This string is to describe the alarm in a readable way, e.g.:
							 | 
						||
| 
								 | 
							
								        +5Vdc Power supply fail."
							 | 
						||
| 
								 | 
							
								   ::= { acdAlarmCfgEntry 3 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmCfgEnable  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      TruthValue
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-write
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "This is to indicate if the alarm is reported or not."
							 | 
						||
| 
								 | 
							
								   ::= { acdAlarmCfgEntry 4 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmCfgSeverity  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      INTEGER {
							 | 
						||
| 
								 | 
							
								                    info(0),
							 | 
						||
| 
								 | 
							
								                    minor(1),
							 | 
						||
| 
								 | 
							
								                    major(2),
							 | 
						||
| 
								 | 
							
								                    critical(3)
							 | 
						||
| 
								 | 
							
								                }
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-write
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "Accedian Networks classifies alarms into four severity types. These types
							 | 
						||
| 
								 | 
							
								        and their associated decimal codes are, informational(0), minor(1),
							 | 
						||
| 
								 | 
							
								        major(2) and critical(3)."
							 | 
						||
| 
								 | 
							
								   ::= { acdAlarmCfgEntry 5 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmCfgServiceAffecting  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      TruthValue
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-write
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "This is to indicate if the alarm is service affecting or not. This
							 | 
						||
| 
								 | 
							
								        value depends on the utilization of the box. For instance in an
							 | 
						||
| 
								 | 
							
								        application where the monitoring of the traffic is mandatory the link
							 | 
						||
| 
								 | 
							
								        down event on the monitor port is service affecting."
							 | 
						||
| 
								 | 
							
								   ::= { acdAlarmCfgEntry 6 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmCfgExtNumber  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE (0..16))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "Unique number that identifies this alarm. Assigned by the unit. The
							 | 
						||
| 
								 | 
							
								        alarm identifier is compose of 3 fields, the module number, the instance
							 | 
						||
| 
								 | 
							
								        number and the error number. The alarm number looks like this:
							 | 
						||
| 
								 | 
							
								        A.B.C and is expressed in decimal, A is the module number, B is
							 | 
						||
| 
								 | 
							
								        the instance number and C is the error number. A module number is
							 | 
						||
| 
								 | 
							
								        assigned for each source of alarm in the system (see Accedian 
							 | 
						||
| 
								 | 
							
								        documentation for more detail)."
							 | 
						||
| 
								 | 
							
								   ::= { acdAlarmCfgEntry 7 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmCfgConditionType  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE (0..32))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "This is the type of alarm condition."
							 | 
						||
| 
								 | 
							
								   ::= { acdAlarmCfgEntry 8 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmCfgAMOType  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString (SIZE (0..128))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "This is the Alarm Maintenance Object."
							 | 
						||
| 
								 | 
							
								   ::= { acdAlarmCfgEntry 9 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								---------------------------------------------------------------------------
							 | 
						||
| 
								 | 
							
								 -- The Alarms Status table
							 | 
						||
| 
								 | 
							
								 -- This table contains the status of all alarms.
							 | 
						||
| 
								 | 
							
								---------------------------------------------------------------------------
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmStatusTable OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      SEQUENCE OF AcdAlarmStatusEntry
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  not-accessible
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "Table of all alarms"
							 | 
						||
| 
								 | 
							
								    ::= { acdAlarm 11 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmStatusEntry OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX  AcdAlarmStatusEntry
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  not-accessible
							 | 
						||
| 
								 | 
							
								    STATUS  current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "An alarm is an exceptional event that requires user notificaton."
							 | 
						||
| 
								 | 
							
								    INDEX   { acdAlarmStatusID }
							 | 
						||
| 
								 | 
							
								    ::=  { acdAlarmStatusTable 1 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								AcdAlarmStatusEntry ::= SEQUENCE {
							 | 
						||
| 
								 | 
							
								    acdAlarmStatusID            Unsigned32,
							 | 
						||
| 
								 | 
							
								    acdAlarmStatusNumber        Unsigned32,
							 | 
						||
| 
								 | 
							
								    acdAlarmStatusOn            TruthValue,
							 | 
						||
| 
								 | 
							
								    acdAlarmStatusLastChange    DateAndTime,
							 | 
						||
| 
								 | 
							
								    acdAlarmStatusMsg           DisplayString
							 | 
						||
| 
								 | 
							
								}
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmStatusID OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      Unsigned32
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "Unique value for each alarm. Its value ranges from 1 to
							 | 
						||
| 
								 | 
							
								        MAXINT (4 bytes). "
							 | 
						||
| 
								 | 
							
								    ::= { acdAlarmStatusEntry 1 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmStatusNumber OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      Unsigned32
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "Unique number that identifies this alarm. Assigned by the unit. The
							 | 
						||
| 
								 | 
							
								        alarm identifier is compose of 3 fields, the module number, the instance
							 | 
						||
| 
								 | 
							
								        number and the error number. The alarm number looks like this:
							 | 
						||
| 
								 | 
							
								        AAA.BBB.CC and is expressed in decimal, AAA is the module number, BBB is
							 | 
						||
| 
								 | 
							
								        the instance number (1-999) and CC is the error number (1-99). A module
							 | 
						||
| 
								 | 
							
								        number is assigned for each source of alarm in the system. For example
							 | 
						||
| 
								 | 
							
								        the port module is set to 1, the SFP module is set to 2, the PAA is set
							 | 
						||
| 
								 | 
							
								        to 3 and the environmental is set to 8."
							 | 
						||
| 
								 | 
							
								    ::= { acdAlarmStatusEntry 2 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmStatusOn  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      TruthValue
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "This is to indicate if the alarm is On or Off."
							 | 
						||
| 
								 | 
							
								    ::= { acdAlarmStatusEntry 3 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmStatusLastChange OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DateAndTime
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "This is the time of the last change for this alarm. A value of zero
							 | 
						||
| 
								 | 
							
								        means that nothing happened to this alarm since the last reboot."
							 | 
						||
| 
								 | 
							
								    ::= { acdAlarmStatusEntry 4 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmStatusMsg  OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      DisplayString  (SIZE (0..32))
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "This string is to add information why the alarm is reported."
							 | 
						||
| 
								 | 
							
								    ::= { acdAlarmStatusEntry 5 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								--  Accedian Alarm Traps
							 | 
						||
| 
								 | 
							
								---------------------------------------------------------------------------
							 | 
						||
| 
								 | 
							
								--    DESCRIPTION "Definition point for Accedian Alarm notifications."
							 | 
						||
| 
								 | 
							
								---------------------------------------------------------------------------
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmV2 OBJECT IDENTIFIER ::= { acdAlarm 12 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmActiveState NOTIFICATION-TYPE
							 | 
						||
| 
								 | 
							
								    OBJECTS  {  acdAlarmCfgID,
							 | 
						||
| 
								 | 
							
								                acdAlarmCfgNumber,
							 | 
						||
| 
								 | 
							
								                acdAlarmCfgSeverity,
							 | 
						||
| 
								 | 
							
								                acdAlarmCfgServiceAffecting,
							 | 
						||
| 
								 | 
							
								                acdAlarmCfgDesc,
							 | 
						||
| 
								 | 
							
								                acdAlarmStatusLastChange,
							 | 
						||
| 
								 | 
							
								                acdAlarmCfgExtNumber,
							 | 
						||
| 
								 | 
							
								                acdAlarmCfgConditionType,
							 | 
						||
| 
								 | 
							
								                acdAlarmCfgAMOType,
							 | 
						||
| 
								 | 
							
								                sysName }
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "The SNMP trap that is generated when an alarm
							 | 
						||
| 
								 | 
							
								         entry crosses its rising threshold and generates
							 | 
						||
| 
								 | 
							
								         an event that is configured for sending SNMP
							 | 
						||
| 
								 | 
							
								         traps."
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								    ::= { acdAlarmV2 1 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmClearState NOTIFICATION-TYPE
							 | 
						||
| 
								 | 
							
								    OBJECTS  {  acdAlarmCfgID,
							 | 
						||
| 
								 | 
							
								                acdAlarmCfgNumber,
							 | 
						||
| 
								 | 
							
								                acdAlarmCfgSeverity,
							 | 
						||
| 
								 | 
							
								                acdAlarmCfgServiceAffecting,
							 | 
						||
| 
								 | 
							
								                acdAlarmCfgDesc,
							 | 
						||
| 
								 | 
							
								                acdAlarmStatusLastChange,
							 | 
						||
| 
								 | 
							
								                acdAlarmCfgExtNumber,
							 | 
						||
| 
								 | 
							
								                acdAlarmCfgConditionType,
							 | 
						||
| 
								 | 
							
								                acdAlarmCfgAMOType,
							 | 
						||
| 
								 | 
							
								                sysName }
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								        "The SNMP trap that is generated when an alarm
							 | 
						||
| 
								 | 
							
								         entry crosses its falling threshold and generates
							 | 
						||
| 
								 | 
							
								         an event that is configured for sending SNMP
							 | 
						||
| 
								 | 
							
								         traps."
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								    ::= { acdAlarmV2 2 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								---------------------------------------------------------------------------
							 | 
						||
| 
								 | 
							
								 -- Transaction ID Information
							 | 
						||
| 
								 | 
							
								---------------------------------------------------------------------------
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmCfgTableLastChangeTid OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      Unsigned32
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "This is the transaction ID of the last change of the acdAlarmCfgTable
							 | 
						||
| 
								 | 
							
								        table.  If this value is different since the last read this is indicate 
							 | 
						||
| 
								 | 
							
								        a table change."
							 | 
						||
| 
								 | 
							
								    ::= { acdAlarmTableTid 1 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmStatusTableLastChangeTid OBJECT-TYPE
							 | 
						||
| 
								 | 
							
								    SYNTAX      Unsigned32
							 | 
						||
| 
								 | 
							
								    MAX-ACCESS  read-only
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "This is the transaction ID of the last change of the acdAlarmStatusTable
							 | 
						||
| 
								 | 
							
								        table.  If this value is different since the last read this is indicate 
							 | 
						||
| 
								 | 
							
								        a table change."
							 | 
						||
| 
								 | 
							
								    ::= { acdAlarmTableTid 2 }
							 | 
						||
| 
								 | 
							
								    
							 | 
						||
| 
								 | 
							
								---------------------------------------------------------------------------
							 | 
						||
| 
								 | 
							
								 -- ACD-ALARM-MIB Module - Conformance Information
							 | 
						||
| 
								 | 
							
								---------------------------------------------------------------------------
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmCompliances  OBJECT IDENTIFIER ::= { acdAlarmConformance 1 }
							 | 
						||
| 
								 | 
							
								acdAlarmGroups       OBJECT IDENTIFIER ::= { acdAlarmConformance 2 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								---------------------------------------------------------------------------
							 | 
						||
| 
								 | 
							
								-- Units of conformance
							 | 
						||
| 
								 | 
							
								---------------------------------------------------------------------------
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmGenGroup OBJECT-GROUP
							 | 
						||
| 
								 | 
							
								    OBJECTS {
							 | 
						||
| 
								 | 
							
								        acdAlarmGenThreshOn,
							 | 
						||
| 
								 | 
							
								        acdAlarmGenThreshOff,
							 | 
						||
| 
								 | 
							
								        acdAlarmGenLedEnable,
							 | 
						||
| 
								 | 
							
								        acdAlarmGenSyslogEnable,
							 | 
						||
| 
								 | 
							
								        acdAlarmGenSNMPEnable,
							 | 
						||
| 
								 | 
							
								        acdAlarmGen8023AHEnable
							 | 
						||
| 
								 | 
							
								    }
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "."
							 | 
						||
| 
								 | 
							
								    ::= { acdAlarmGroups 1 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmCfgGroup OBJECT-GROUP
							 | 
						||
| 
								 | 
							
								    OBJECTS {
							 | 
						||
| 
								 | 
							
								        acdAlarmCfgID,
							 | 
						||
| 
								 | 
							
								        acdAlarmCfgNumber,
							 | 
						||
| 
								 | 
							
								        acdAlarmCfgDesc,
							 | 
						||
| 
								 | 
							
								        acdAlarmCfgEnable,
							 | 
						||
| 
								 | 
							
								        acdAlarmCfgSeverity,
							 | 
						||
| 
								 | 
							
								        acdAlarmCfgServiceAffecting,
							 | 
						||
| 
								 | 
							
								        acdAlarmCfgExtNumber,
							 | 
						||
| 
								 | 
							
								        acdAlarmCfgConditionType,
							 | 
						||
| 
								 | 
							
								        acdAlarmCfgAMOType
							 | 
						||
| 
								 | 
							
								    }
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "."
							 | 
						||
| 
								 | 
							
								    ::= { acdAlarmGroups 2 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmStatusGroup OBJECT-GROUP
							 | 
						||
| 
								 | 
							
								    OBJECTS {
							 | 
						||
| 
								 | 
							
								        acdAlarmStatusID,
							 | 
						||
| 
								 | 
							
								        acdAlarmStatusNumber,
							 | 
						||
| 
								 | 
							
								        acdAlarmStatusOn,
							 | 
						||
| 
								 | 
							
								        acdAlarmStatusLastChange,
							 | 
						||
| 
								 | 
							
								        acdAlarmStatusMsg
							 | 
						||
| 
								 | 
							
								    }
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "."
							 | 
						||
| 
								 | 
							
								    ::= { acdAlarmGroups 3 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmNotificationsGroup NOTIFICATION-GROUP
							 | 
						||
| 
								 | 
							
								    NOTIFICATIONS {
							 | 
						||
| 
								 | 
							
								        acdAlarmActiveState,
							 | 
						||
| 
								 | 
							
								        acdAlarmClearState
							 | 
						||
| 
								 | 
							
								    }
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "Objects for the Notifications group."
							 | 
						||
| 
								 | 
							
								    ::= { acdAlarmGroups 4 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								acdAlarmTidGroup OBJECT-GROUP
							 | 
						||
| 
								 | 
							
								    OBJECTS {
							 | 
						||
| 
								 | 
							
								        acdAlarmCfgTableLastChangeTid,
							 | 
						||
| 
								 | 
							
								        acdAlarmStatusTableLastChangeTid
							 | 
						||
| 
								 | 
							
								    }
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "List of scalars to monitior changes in tables."
							 | 
						||
| 
								 | 
							
								    ::= { acdAlarmGroups 5 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								---------------------------------------------------------------------------
							 | 
						||
| 
								 | 
							
								-- MIB Module Compliance statements
							 | 
						||
| 
								 | 
							
								---------------------------------------------------------------------------
							 | 
						||
| 
								 | 
							
								acdAlarmCompliance MODULE-COMPLIANCE
							 | 
						||
| 
								 | 
							
								    STATUS      current
							 | 
						||
| 
								 | 
							
								    DESCRIPTION
							 | 
						||
| 
								 | 
							
								       "The compliance statement for support of the ACD-ALARM-MIB module."
							 | 
						||
| 
								 | 
							
								    MODULE
							 | 
						||
| 
								 | 
							
								        MANDATORY-GROUPS {
							 | 
						||
| 
								 | 
							
								            acdAlarmGenGroup,
							 | 
						||
| 
								 | 
							
								            acdAlarmCfgGroup,
							 | 
						||
| 
								 | 
							
								            acdAlarmStatusGroup,
							 | 
						||
| 
								 | 
							
								            acdAlarmNotificationsGroup,
							 | 
						||
| 
								 | 
							
								            acdAlarmTidGroup
							 | 
						||
| 
								 | 
							
								        }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								    ::= { acdAlarmCompliances 1 }
							 | 
						||
| 
								 | 
							
								
							 | 
						||
| 
								 | 
							
								END
							 |