Update MIBs (#14017)

This commit is contained in:
Jellyfrog
2022-06-07 16:01:34 +02:00
committed by GitHub
parent b8f2002150
commit 1cf067a079
67 changed files with 60644 additions and 51930 deletions

View File

@@ -29,7 +29,7 @@ IMPORTS
FROM SNMPv2-TC;
fortinet MODULE-IDENTITY
LAST-UPDATED "201501140000Z"
LAST-UPDATED "202001300000Z"
ORGANIZATION
"Fortinet Technologies, Inc."
CONTACT-INFO
@@ -37,38 +37,53 @@ fortinet MODULE-IDENTITY
email: support@fortinet.com
http://www.fortinet.com
"
DESCRIPTION
"Registered FortiWANMib OIDs"
REVISION "201501140000Z"
DESCRIPTION
"Registered and updated FortiAuthenticatorMib/FortiRecorderMib/FortiVoiceMib/FortiBridgeMib/FortiDirectorMib OIDs"
REVISION "201412100000Z"
DESCRIPTION
"Registered FortiVoiceMib OID"
REVISION "201404100000Z"
DESCRIPTION
"Registered FortiADCMib OID"
REVISION "201403220000Z"
DESCRIPTION
"Added fan failure and AMC bypass traps"
REVISION "201205090000Z"
DESCRIPTION
"Registered FortiDDoSMib OID"
REVISION "201204230000Z"
DESCRIPTION
"Registered FortiDNSMib OID"
REVISION "201112230000Z"
DESCRIPTION
"Registered FortiCacheMib OID"
REVISION "201104250000Z"
DESCRIPTION
"Supporting portuguese language"
REVISION "201005140000Z"
DESCRIPTION
"Registered FortiScanMib OID"
REVISION "200905200000Z"
DESCRIPTION
"MIB module for Fortinet network devices."
REVISION "202001300000Z"
DESCRIPTION
"Registered FortiExtenderMib OIDs"
REVISION "201812050000Z"
DESCRIPTION
"Registered FortiAPMib OIDs"
REVISION "201811050000Z"
DESCRIPTION
"Registered FortiDDoSCMMib OIDs"
REVISION "201609300000Z"
DESCRIPTION
"Corrected trap number and description of nTrapIfEnterBypassMode/fnTrapIfExitBypassMode Traps "
REVISION "201605240000Z"
DESCRIPTION
"Added fnTrapIfEnterBypassMode/fnTrapIfExitBypassMode Traps "
REVISION "201501140000Z"
DESCRIPTION
"Registered FortiWANMib OIDs"
REVISION "201412100000Z"
DESCRIPTION
"Registered and updated FortiAuthenticatorMib/FortiRecorderMib/FortiVoiceMib/FortiBridgeMib/FortiDirectorMib OIDs"
REVISION "201404100000Z"
DESCRIPTION
"Registered FortiVoiceMib OID"
REVISION "201403220000Z"
DESCRIPTION
"Registered FortiADCMib OID"
REVISION "201205090000Z"
DESCRIPTION
"Added fan failure and AMC bypass traps"
REVISION "201204230000Z"
DESCRIPTION
"Registered FortiDDoSMib OID"
REVISION "201112230000Z"
DESCRIPTION
"Registered FortiDNSMib OID"
REVISION "201104250000Z"
DESCRIPTION
"Registered FortiCacheMib OID"
REVISION "201005140000Z"
DESCRIPTION
"Supporting portuguese language"
REVISION "200905200000Z"
DESCRIPTION
"Registered FortiScanMib OID"
REVISION "200811190000Z"
DESCRIPTION
"Registered FortiWebMib OID"
@@ -175,6 +190,9 @@ fnCoreMib OBJECT IDENTIFIER ::= { fortinet 100 }
-- fnFortiBridgeMib OBJECT IDENTIFIER ::= { fortinet 116 }
-- fnFortiDirectorMib OBJECT IDENTIFIER ::= { fortinet 117 }
-- fnFortiWANMib OBJECT IDENTIFIER ::= { fortinet 118 }
-- fnFortiDDoSCMMib OBJECT IDENTIFIER ::= { fortinet 119 }
-- fnFortiAPMib OBJECT IDENTIFIER ::= { fortinet 120 }
-- fnFortiExtenderMib OBJECT IDENTIFIER ::= { fortinet 121 }
--
--
@@ -360,7 +378,7 @@ fnTrapAmcIfBypassMode NOTIFICATION-TYPE
"An AMC interface entered bypass mode. Available on models with an AMC
expansion slot. Used with the ASM-CX4 and ASM-FX2 cards."
::= { fnTrapsPrefix 107 }
fnTrapFanFailure NOTIFICATION-TYPE
OBJECTS { fnSysSerial, sysName }
STATUS current
@@ -369,6 +387,20 @@ fnTrapFanFailure NOTIFICATION-TYPE
See manual for specifications."
::= { fnTrapsPrefix 108 }
fnTrapIfEnterBypassMode NOTIFICATION-TYPE
OBJECTS { fnSysSerial, sysName }
STATUS current
DESCRIPTION
"Interface entered bypass mode. Available on models with bypass ports."
::= { fnTrapsPrefix 109 }
fnTrapIfExitBypassMode NOTIFICATION-TYPE
OBJECTS { fnSysSerial, sysName }
STATUS current
DESCRIPTION
"Interface exited bypass mode. Available on models with bypass ports."
::= { fnTrapsPrefix 110 }
fnTrapIpChange NOTIFICATION-TYPE
OBJECTS { fnSysSerial, sysName, ifIndex }
STATUS current
@@ -414,7 +446,8 @@ fnTrapsComplianceGroup NOTIFICATION-GROUP
NOTIFICATIONS { fnTrapCpuThreshold, fnTrapMemThreshold,
fnTrapLogDiskThreshold, fnTrapTempHigh,
fnTrapVoltageOutOfRange, fnTrapPowerSupplyFailure,
fnTrapAmcIfBypassMode, fnTrapFanFailure,
fnTrapAmcIfBypassMode, fnTrapIfEnterBypassMode,
fnTrapIfExitBypassMode, fnTrapFanFailure,
fnTrapIpChange, fnTrapTest }
STATUS current
DESCRIPTION

View File

@@ -22,7 +22,7 @@ IMPORTS
FROM SNMPv2-TC;
fnFortiAuthenticatorMib MODULE-IDENTITY
LAST-UPDATED "201506080000Z"
LAST-UPDATED "201901170000Z"
ORGANIZATION
"Fortinet Technologies, Inc."
CONTACT-INFO
@@ -32,6 +32,12 @@ fnFortiAuthenticatorMib MODULE-IDENTITY
"
DESCRIPTION
"MIB module for Fortinet FortiAuthenticator devices"
REVISION "202004160000Z"
DESCRIPTION
"Include RAID status"
REVISION "201901170000Z"
DESCRIPTION
"Include Fsso user data and add facmodel information"
REVISION "201506080000Z"
DESCRIPTION
"Include Radius proxy, high availability data"
@@ -51,10 +57,10 @@ FacHaState ::= TEXTUAL-CONVENTION
"Enumerated type for FAC High Availability states"
SYNTAX INTEGER {
unknownOrDetermining (1),
clusterMaster (2),
clusterSlave (3),
standaloneMaster (4),
loadBalancingSlave (5),
clusterPrimary (2),
clusterSecondary (3),
standalonePrimary (4),
loadBalancer (5),
disabled (255)
}
@@ -74,6 +80,9 @@ facAuth OBJECT IDENTIFIER
facMIBConformance OBJECT IDENTIFIER
::= { fnFortiAuthenticatorMib 600 }
facModel OBJECT IDENTIFIER
::= { fnFortiAuthenticatorMib 100 }
--
-- fortinet.fnFortiAuthenticatorMib.facSystem
--
@@ -129,7 +138,6 @@ facHaCurrentStatus OBJECT-TYPE
DESCRIPTION "Instantaneous HA status for this node"
::= { facHa 1 }
-- fnFortiAuthenticatorMib.facSystem.facAuth
facAuthUserCount OBJECT-TYPE
SYNTAX FnIndex
@@ -306,6 +314,34 @@ facRadiusProxyOutTotal OBJECT-TYPE
DESCRIPTION "Number of Radius accounting proxy requests sent since startup"
::= { facAuth 25 }
facFssoUserCount OBJECT-TYPE
SYNTAX FnIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of signed-in fsso users"
::= { facAuth 26 }
facFssoUserRemaining OBJECT-TYPE
SYNTAX FnIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of fsso users can still signed in before reaching the table limit"
::= { facAuth 27 }
facRaidStatus OBJECT-TYPE
SYNTAX INTEGER {
none(0), -- no raid detected or status unknown
ok(1),
degraded(2), -- at least one failed disk, but raid is still functioning
failed(3), -- raid does not work any more, has to be deleted and re-created
initializing(4),
verifying(5),
rebuilding(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RAID status"
::= { facAuth 28 }
--
-- fnFortiAuthenticatorMib.facTraps
@@ -359,6 +395,19 @@ facTrapHAStatusChange NOTIFICATION-TYPE
"The FAC device's HA status has changed."
::= { facTraps 106 }
facTrapHASyncActivityLow NOTIFICATION-TYPE
OBJECTS { facSysSerial, sysName, fnGenTrapMsg }
STATUS current
DESCRIPTION
"There has been low HA sync activity recently."
::= { facTraps 107 }
facTrapRaidStatusChange NOTIFICATION-TYPE
OBJECTS { facSysSerial, facRaidStatus }
STATUS current
DESCRIPTION
"The FAC device's RAID status has changed."
::= { facTraps 108 }
--
-- fnFortiAuthenticatorMib.facMIBConformance
@@ -374,7 +423,9 @@ facSystemConformanceGroup OBJECT-GROUP
facLdapLoginsTotal, facLdapLogins5Mins, facLdapFailuresTotal,
facLdapFailures5Mins, facAuthEventsTotal, facAuthEvents5Mins,
facAuthFailuresTotal, facAuthFailures5Mins, facHaCurrentStatus,
facRadiusProxyInTotal, facRadiusProxyOutTotal }
facRadiusProxyInTotal, facRadiusProxyOutTotal,
facFssoUserCount, facFssoUserRemaining, facRaidStatus
}
STATUS current
DESCRIPTION "Basic FortiAuthenticator system information"
::= { facMIBConformance 1 }
@@ -383,7 +434,8 @@ facTrapsConformanceGroup NOTIFICATION-GROUP
NOTIFICATIONS { facTrapAuthUsersThreshold, facTrapAuthGroupThreshold,
facTrapRadiusNasThreshold, facTrapAuthEventsThreshold,
facTrapAuthFailureThreshold, facTrapUserLockout,
facTrapHAStatusChange }
facTrapHAStatusChange, facTrapHASyncActivityLow,
facTrapRaidStatusChange }
STATUS current
DESCRIPTION "Event notifications."
::= { facMIBConformance 2 }
@@ -402,6 +454,28 @@ facMIBCompliance MODULE-COMPLIANCE
devices."
::= { facMIBConformance 100 }
-- facModel start
facvm OBJECT IDENTIFIER ::= { facModel 101 }
facvmhv OBJECT IDENTIFIER ::= { facModel 102 }
facvmxen OBJECT IDENTIFIER ::= { facModel 103 }
facvmkvm OBJECT IDENTIFIER ::= { facModel 104 }
facdocker OBJECT IDENTIFIER ::= { facModel 105 }
fac2hd OBJECT IDENTIFIER ::= { facModel 204 }
fac2he OBJECT IDENTIFIER ::= { facModel 205 }
fac4hc OBJECT IDENTIFIER ::= { facModel 303 }
fac4he OBJECT IDENTIFIER ::= { facModel 305 }
fac1kc OBJECT IDENTIFIER ::= { facModel 403 }
fac1kd OBJECT IDENTIFIER ::= { facModel 404 }
fac2ke OBJECT IDENTIFIER ::= { facModel 505 }
fac3kd OBJECT IDENTIFIER ::= { facModel 604 }
fac3ke OBJECT IDENTIFIER ::= { facModel 605 }
fac3hf OBJECT IDENTIFIER ::= { facModel 706 }
fac8hf OBJECT IDENTIFIER ::= { facModel 806 }
-- facModel end
END