From 21a70dcb8ac3eb8d0b35647f287b742fedb2d8c8 Mon Sep 17 00:00:00 2001 From: Neil Lathwood Date: Sat, 22 Apr 2017 14:11:21 +0100 Subject: [PATCH] newdevice: Added basic detection for Geist Watchdog (#6467) * newdevice: Added basic detection for Geist Watchdog * Added further support * Added more health sensors --- html/images/logos/geist.png | Bin 0 -> 6123 bytes html/images/os/geist.png | Bin 0 -> 1499 bytes includes/definitions/geist-watchdog.yaml | 11 + .../sensors/airflow/geist-watchdog.inc.php | 29 + .../sensors/humidity/geist-watchdog.inc.php | 38 + .../temperature/geist-watchdog.inc.php | 53 + .../sensors/voltage/geist-watchdog.inc.php | 29 + includes/polling/os/geist-watchdog.inc.php | 26 + mibs/geist/GEIST-MIB-V3 | 11477 ++++++++++++++++ mibs/geist/GEIST-V4-MIB | 1404 ++ tests/OSDiscoveryTest.php | 5 + tests/snmpsim/geist-watchdog.snmprec | 2 + 12 files changed, 13074 insertions(+) create mode 100644 html/images/logos/geist.png create mode 100644 html/images/os/geist.png create mode 100644 includes/definitions/geist-watchdog.yaml create mode 100644 includes/discovery/sensors/airflow/geist-watchdog.inc.php create mode 100644 includes/discovery/sensors/humidity/geist-watchdog.inc.php create mode 100644 includes/discovery/sensors/temperature/geist-watchdog.inc.php create mode 100644 includes/discovery/sensors/voltage/geist-watchdog.inc.php create mode 100644 includes/polling/os/geist-watchdog.inc.php create mode 100644 mibs/geist/GEIST-MIB-V3 create mode 100644 mibs/geist/GEIST-V4-MIB create mode 100644 tests/snmpsim/geist-watchdog.snmprec diff --git a/html/images/logos/geist.png b/html/images/logos/geist.png new file mode 100644 index 0000000000000000000000000000000000000000..fa356ae2dad43dab17d0660bb2e8b420bcb185af GIT binary patch literal 6123 zcmaJ_c|25Y`=7CwEiGghiLwmC7{W2wAff*@i4xipahb71;`f zM;LpdnUQ4YH$BhW`+NU*KkxZ`&bjY%-PiTKw(oWRIB}*X`mCpUP6Ge{Rzm|FbL#qw zdRs6tP@gY)_8(IhZmg~i)&k{<4Md=k08JOv9i)(S{tNI2aYc8;L~-;k>i)MFBrNo|3f5Cq z_@AI`j7^2KQD~$PL>eOHECZGmf+|VNLLg8mSW*ZqBP$P*kp;=hNy#d~3bATU^psv(65^1&i- zQa%`wKL|QVj5FH97wduY5&DgYxP$V?stQvh{U-%)Ut{Bc1N&h9RVZr7KsbaiNLE?~ zZl4+Po!NuTwpQ~MHyLHsJsjmETf<(E32q2E3c~ukx`I?=*sCpl>T7+ zH(MQDMX)?nOGaDgH-@gfmbR9Xo~DkrrlO)2L{CrikFB8(28-}Vl%gU6EQN4I$RnMR^71Zn^1}bJclnR% z{likKgqn%(pMYSla$p5lMX;+B6^u$jS*W5E0s@6l(OkjKvT`yCNQiJHsW&<*FD-v6}F~utqrkAQOzhUG=bsK1u;U1jPG`y=Ne)_aQ z+2zbwbhE|@c@OT@c#vDW6GXz0Zp}4zgpzZ!raT2s2D2fauGY;@KE`ymwr_r=ab$O7 z4Qmf_YnC-AMhXi<4rgyFYF}%L~xU=0X1R4!g{TdV; zFH6O7#qq5I(faV&tuB!=AKJl_`fJpatJD)c9QFrbZ-DrWATB}YTJhJ*n|GI=3S<*M z@*dJY+R|A!(erz{#+0{IC@~H`o=m*(V$&b0?avttfG)7vp6BB%_XBBQJC)Zdu zTjeWL%Vt7*yC_%|9Isye(GPXz$*DDmv0ew}W7SUlyT#KKQD6X_NYN`t=dm@Wl&B ziSJKMrUSnsSOJ5Q;eo)G=l+aE*BJv!XoKM@(sZ}Koptm>#M$9qMorsJ$by~TF@E@x zP%8U^9k;_|7&N*eOA*TSeH$b%_@mBqEQ6sXG~V(MGH_G!M5fqYYICxP3A{Pjb*-;n zRfC~nq;wm_zwjd2^rec;cp=jdOu_9_Qw>40L)s>FV~^IBTvV5AZD%w9p>5;e$3$-K zUZ*%wdJF??mbRDqy1$IeHPwOcKn}Ucq)5Hn*;-XMafde)V%ihLCurJQC6+37`d&Nm z5G35!PVqieR0Xr>sr#RTcZDX1pP09`o^zSLFBbUt7^qhF=!hSkSYG8MGd8p374fy~ zLH`Lu2fK<|zA~_k(tuN;ReM2arNw*#o#dchf_)NA9wwR5G`rU=1uRGqstKfYHVrrP z9w1(Uu@8RG*DK6!U|6`J5~DIL`sD?ClI9NC${_;px`=)rZ+Ej&xFQ-JL1uiidcockIp=h?cp} zsw&Iz1weZtUYPBgY*`dT&Xw%)fl*b?9~j&1*0WKt3`>UeBz{%uU-gZ@m9BNaaU ztPPRPKw^LAj!pDxBzt@W-;}^bn8RIP`?6Vl9&dps-FX^V1@JECE|4Pls_k-35T}Rx zb$PYqV<8ldfDO-#pyIug5~+Z&DJK!*i_+Gv9Gd~iEF4w-G{;EMP89?%lfkT_Xh zj#dN6oQUYlz5;%&x%&F*n20XVw@d~v?vk|Ug1gPaeLAggnNuXDEh5Tu<4N@JACKXc}n%5DagG0zI4KOt$p7R{Ihj=bea z>tH-)-PHsH`=3fUTaA9AOB`vvA+k6L@I(OP3kGe5IVD_>OY zeYT84Xe8@GQT)2XSaGY{c>CfT^G5yNr9@ncEXuoFL+U!RJG3_OQIk;79Ph9=p^Kqx z+UW6JUfHXS=_E#VyMAaB^;@%^=x`1=p1V!J#vQF%zc5TnTwvb#>x|!Ld@P!kRio3> zcuJ^T+R3n{)5_>xL>`G{SGat-ZMdl_jaNUGyHHvmr}XwNx8JL$H*w@s+zd1K?inQo zNftfyXA3%HJhZ)Sm zho*@G%|^*x$ANK69T$il@2PyLhQf;MzcPNkKO<3T3hN0?#)#I|ADRei3wo z;T_7JolhFJ8u+@6x#s1rkL#CN&A4($Fzy-Dz2X02@5tLqYoo?7mDQopH8+zWcr zEY{jf&-k##*REu*m{c|~IWIoku`tVha1`@Q8FNJ|cAl^Sy$3BqH+h~jo4Tn8_4a7(b!;VG+o=X5B|*n1U)RlP8!Bsh0zUiWUL<6* z<>iz{=rJCiUs)^g$B_%cRdS>K9rw)qrO^DLR>1D7c zPjyn_wG=PG>ApU^1K26^V5g^nu5zH-)ziLUr=%tOU2A5+L|ol55en zd1O-4)3GIijlL;%x!HMxzC+{gP@~bsE^;P-^SdJ}*Ys%WJ8V#YtPh4ILrR8CqQMs>P2~H{a-5D zJ)mS@6N;IMmvnYcOu~Ao#xHL9S%zOAU$=#HS5;D~{nUQ^?GY$gr^AL;;s|nKO%1J)arnrd(T2D&OWlhF|EY zzYpGe72Qo=#W>m!PZO{;Ea;%y6B(AW%%!}*M9SP$)LOH9>W1QZA3UGe4(5JFIdJdS zbsm2vY|Wf`_1KndyVLKPv_iN0SlucT_~6xMZRZhlO1NpzvCUw;vFxW!@2W^9{>YfF zoauUx0hCg>UM|^xZf$Aes&L;MR94>e>6^D&7x>`DK7pV1T)3H)IGgfz+Wq>^EOnX~ zM*$?>25=#9wOxUP&2*#2;P+c>vyByJBOKQ4k+ba5Mr+fe_JO5o2|^(v3~0$fZZ=FA zTc)K=exFg$d&Ju+w4REbAChKv%Ug=BEed@)`Z{kkuUO?~4utyelbGd7%>TdUe<+TaL zn#*=jYd;JF3ck1yE}uf|AC@yCFBO0V5&b91YyI8N z*`Ii;7z9a9pyk^zaB@=eSnRLRskH1E9npio-!_KZ3j68yzzC@6y7|i zDr_9B8l5}jb!l|&5pE^d8zVjXA;MYm_1F4O@#L<#cTAKVOZEX(58Lo}B3@0$!uaCC@R@m9}v zHLlNyaQw1<^Q|~wx%k#{YJTXZ4Qt!O=RSKKb0Xhwd4!Zg(_rarDs2EV4aFS$6G+U^ zCDcGO03Qw__u^))weZ=ieyF}5R)OVFX_G-=#oYmc5Lf0;;p*kNCL`;}5TdpIyD|$( z_QIHN~n;Mi2Qdw~)l&$E3=Sr5ru zcw)WIugZ~sMXO)(G?#xo zdKfc5#gp>ngynuH@QXRJfG;mCTljUz!loysQ~m*5GYe`orf58c_EqiVa783%>$mnk zJ;3&6+B1gn=XHRZo{i#@!1aK+r&-JB%sm?+w^D7>*d8qxbspAQgL~l>2H6fx8T)6# zcNkyxr=Zk(o6n5A#B(i>Z!ZMZ^K@9;U&xQG+gVVu&5p`HzCRaU$mX!9Mmnvm@f{ng z0gLQl9Gw-#-xIi3Ob9&_R>a&?N$-zsG5WGNBszGm16E;iVBgKn>UR*CKEdhdn)f`o z$?_E;x190-4#}E+UPNh}xPlg7ys;cu!%*n6pH%zPn@9XFi4A5V$1V1`<5)XU{p zG-kz$H4m>l6?CurPKj|!33g|C9x<5)5fepg0Svag`t z*R%Mgt*?rnc0Q6UIsK9nzINm_!O?dB+u1Y%UkSk*^TAI}zDW}bMh7tuTnlfEU%%UZ z2Vcn5bVlG#eHC6`K}kFUlu{F0JM4IAY2FJbzjkeHC$;%4L7b5P?vB^aU?S=+Kh#Wa zB2ri!mRFoMD}6zk1+p!563L>yh@87vQc@78fC7?|gYU7cSn8?pv`9b7SRM*_J}|^p z_*dv*n^q{p^m#~jt$dmE5?WY$b{iOEz4yLacUjFS{j}JGr)uX`&P*jG#Cm(aIp3XW zSR*%%A~v)IiV;_wFjV=~ct%J`X(Z1z^eLXzcEof~z^_{nzB9&DJ`>d)t?1Wam%Qn| z5u~n!E5m#@qjQ?8+;;a=?KzXlTltYAz1F@J&mF|Od(#(1G3v-K4}fdz!zDx@St>@f1y*Tci&ek*gqoY;%ar6R2Q4|7t&5Cr^;VwbDlk^e=OPw}tjX=b4pIfUy2qVJA( zkLXwdbukZrN@^z;@%L_3T{RD9&vbA?O`Vozy_gtKb`0vqJP6>pS$vgo%OkF7?s0s0 zMZlHG)v!tmtb9UFG$iCcS!|k?G5v_*7?PLJQ<)t5&YhX>aD0zM|1=1 z_+BMq^*ws1r8xaVI|0m+a%t~*{Kz(0?zAAeAC>fSW42{Y%6mtNyKBGXF0BuIe#&Ss z`7vU{gW?HhJJw=&-70#JH##}_d8?TJ-dt^i7@<^|Yjf#5Uel9kx~fGRkaI01gea;M z$dWbPoEP#DFlcMiTRo&q$JvTe3|B@A>K0;(jb@nzpdwBF}IZXc7zdJs;I3p zuVXXRunuYXEAfYpRS@7Tt6-FUUHj|Dx1egn{`Uxg8OwE!h58lvT`0_B}PH5?Mlh}wb01NpxgRV zr{U)%J%)`#K(2tt&#UTJ?wG@zREoP1(8{MHapH1T-Y}srR^k$Esb*1h4P8UrIi#d7 zYx|bHOFw6yvipvMBu3B0zOAvY%t~UJjHXvS^7=-aD8;{=Z@AF-lJIH;0(Ro!BK|BX z3CG5&xEg)R3;W(kJD&5xgQ{Kvgu*j6mnKIX7OoZ8KM*Ux(Rju|%2Ul))beTZV&uP5*1i|ydFnH3(q{pRi6>Q{qxZj+gq=6o_2Q7*nwOfR4 z;TpzCnU#BqiSGfE0{AU3bT)C`UuRxco$yyM*sc>TB2t6{9J0uapxHCTa#B;xnD+Al aw19l}+GSD7LeTHu?}oZ2I#pUuk^cvmS3^ty literal 0 HcmV?d00001 diff --git a/html/images/os/geist.png b/html/images/os/geist.png new file mode 100644 index 0000000000000000000000000000000000000000..ebdbe53c42265f382ea5c13c9fc4c3fdf48e00dc GIT binary patch literal 1499 zcmV<11tj{3P)WFU8GbZ8()Nlj2>E@cM*00louL_t(o!^M|tP*i0Y z$A8PNunTwr!NQ2VmDftNF>};0(wbp{#>~=TMx&-wrqNMzbW)g7`k?7Jc^R9)7!wD@ zA}@(BaS?D8aCd=G1P8CI#%*C?FD%Q#o<1CR51<(=Ha=h8|8w5w@_*m+yzhCAj6O1b zGL%>KewMKh<(N=>PvzkM#;eRaUqF{qMdjWUY8a%*00M_YOIz=W)yo*QF_v(Xg=w}9 zygMCq**dtdt0XgiKWzY|Ct<+~Xt(u0Vf-4{aY)2L0r<*#PQE*b3A;BF9TdQaoeo}T zZsnYzg)^Zc+?e`4dcX-VV+!c54{W8rN@(wpR9yy}LW22-{qaoJWpF^BPor6jP*;Th z{LicdhPbS^t@dntKVKr@%O~(k+RligRCXClu$#3A#u7TQmT|DX452!c3t7p`?-}6v zAkPx--X!6SoZm; zn5XnXsjowOI+ulG-y!_HFGzLyDm+=K+zb9V0MT)x-s!+Q=NHBV1+rpPAX`QZL*CT| z-Q5^0Hp(*#`EFGL7atePBLY`X!;~lhe2PyHJvx{rDkYJ=DuyC}!N{#n2gmO|;MBrc zG=2TULhv3GfhkdtbC?$=jVH~|mzhHpC}lEeFmR*tCJEz0`D)8CsdNKj_ZR>6OZ^;Kmz{iJ9g&bM+9S+V~%KDyjYZIUB z>vT%k%Tof{N*s0vjs^qQ0p`u@zi-%RsRleIP;`aPt}g8L23i4%wEg#0`XC!Lfn(=z zI0fv+Hj#j*;xU2xCOTzcx7wZ&0l=Y7vSdT7^gbUat3H-+#9R1RoFb++p9+f( zq3IG1O46B7lf@a62En33XjD^Mb&elE3jFq)j}N|h5pxzVl5VxW67{x(3y!j~QH{2> zlx|x&!rfeMT|7p#+u+YbENi-i-J%ma7eg_&oD|#}H$Lpq1mTky8$Jnn-{-GQl<>Z- zOsmbK+@!&2)*>_)<5Z`yeR(9Z*C#)$Xu;~X_p8a~NJ|M87m+);Tq`|EWO5?Id(;a6 z!GWlP1I4=W@diQqpYX~_VcOL*95I$4Sj)urtFDN`t9W9X_4(YgmPy3!U*Nj-cUHMyReV4G4WA^_Cqa3&h*Nhl zbV3-*$At3JP(Ng@&PFDK4m;fYn*?hIN%Lc8y3>Le;?I{R6WNMrc(3BaZ+8002ovPDHLkV1gv= Byv+ar literal 0 HcmV?d00001 diff --git a/includes/definitions/geist-watchdog.yaml b/includes/definitions/geist-watchdog.yaml new file mode 100644 index 0000000000..adc68fd358 --- /dev/null +++ b/includes/definitions/geist-watchdog.yaml @@ -0,0 +1,11 @@ +os: geist-watchdog +text: 'Geist Watchdog' +type: environment +icon: geist +discovery: + - sysObjectId: + - .1.3.6.1.4.1.21239. +mib_dir: + - geist +over: + - { graph: device_bits, text: 'Device Traffic' } diff --git a/includes/discovery/sensors/airflow/geist-watchdog.inc.php b/includes/discovery/sensors/airflow/geist-watchdog.inc.php new file mode 100644 index 0000000000..8928f821c0 --- /dev/null +++ b/includes/discovery/sensors/airflow/geist-watchdog.inc.php @@ -0,0 +1,29 @@ +. + * + * @package LibreNMS + * @link http://librenms.org + * @copyright 2017 Neil Lathwood + * @author Neil Lathwood + */ + +$value = snmp_get($device, 'climateAirflow', '-Oqv', 'GEIST-MIB-V3'); +$current_oid = '.1.3.6.1.4.1.21239.2.2.1.9.1'; +$descr = 'Airflow'; +discover_sensor($valid['sensor'], 'airflow', $device, $current_oid, 'climateAirflow', 'geist-watchdog', $descr, 1, 1, null, null, null, null, $value); diff --git a/includes/discovery/sensors/humidity/geist-watchdog.inc.php b/includes/discovery/sensors/humidity/geist-watchdog.inc.php new file mode 100644 index 0000000000..b2489dd03e --- /dev/null +++ b/includes/discovery/sensors/humidity/geist-watchdog.inc.php @@ -0,0 +1,38 @@ +. + * + * @package LibreNMS + * @link http://librenms.org + * @copyright 2017 Neil Lathwood + * @author Neil Lathwood + */ + +$value = snmp_get($device, 'climateHumidity', '-Oqv', 'GEIST-MIB-V3'); +if ($value) { + $current_oid = '.1.3.6.1.4.1.21239.2.2.1.7.1'; + $descr = 'Humidity'; + discover_sensor($valid['sensor'], 'humidity', $device, $current_oid, 'climateHumidity', 'geist-watchdog', $descr, 1, 1, null, null, null, null, $value); +} + +$value = snmp_get($device, 'internalHumidity.1', '-Oqv', 'GEIST-V4-MIB'); +if ($value) { + $current_oid = '.1.3.6.1.4.1.21239.5.1.2.1.6.1'; + $descr = 'Internal humidity'; + discover_sensor($valid['sensor'], 'humidity', $device, $current_oid, 'internalHumidity.1', 'geist-watchdog', $descr, 1, 1, null, null, null, null, $value); +} diff --git a/includes/discovery/sensors/temperature/geist-watchdog.inc.php b/includes/discovery/sensors/temperature/geist-watchdog.inc.php new file mode 100644 index 0000000000..7bac4f0739 --- /dev/null +++ b/includes/discovery/sensors/temperature/geist-watchdog.inc.php @@ -0,0 +1,53 @@ +. + * + * @package LibreNMS + * @link http://librenms.org + * @copyright 2017 Neil Lathwood + * @author Neil Lathwood + */ + +$value = snmp_get($device, 'climateTempC', '-Oqv', 'GEIST-MIB-V3'); +if ($value) { + $current_oid = '.1.3.6.1.4.1.21239.2.2.1.5.1'; + $descr = 'Temperature'; + discover_sensor($valid['sensor'], 'temperature', $device, $current_oid, 'climateTempC', 'geist-watchdog', $descr, 1, 1, null, null, null, null, $value); +} + +$value = snmp_get($device, 'internalTemp.1', '-Oqv', 'GEIST-V4-MIB'); +if ($value) { + $current_oid = '.1.3.6.1.4.1.21239.5.1.2.1.5.1'; + $descr = 'Internal temperature'; + $divisor = 10; + $value = $value / $divisor; + discover_sensor($valid['sensor'], 'temperature', $device, $current_oid, 'internalTemp.1', 'geist-watchdog', $descr, $divisor, 1, null, null, null, null, $value); +} + +$temp_table = snmpwalk_cache_oid($device, 'tempSensorTable', array(), 'GEIST-MIB-V3'); + +foreach ($temp_table as $index => $temp_data) { + if ($temp_data['tempSensorAvail'] == 1) { + $current_oid = '.1.3.6.1.4.1.21239.2.4.1.5.' . $index; + $descr = $temp_data['tempSensorName'] . ': #' . $temp_data['tempSensorSerial']; + $value = $temp_data['tempSensorTempC']; + discover_sensor($valid['sensor'], 'temperature', $device, $current_oid, $index, 'geist-watchdog', $descr, 1, 1, null, null, null, null, $value); + } +} + +unset($temp_table); diff --git a/includes/discovery/sensors/voltage/geist-watchdog.inc.php b/includes/discovery/sensors/voltage/geist-watchdog.inc.php new file mode 100644 index 0000000000..31ad7fc25f --- /dev/null +++ b/includes/discovery/sensors/voltage/geist-watchdog.inc.php @@ -0,0 +1,29 @@ +. + * + * @package LibreNMS + * @link http://librenms.org + * @copyright 2017 Neil Lathwood + * @author Neil Lathwood + */ + +$value = snmp_get($device, 'climateVolts', '-Oqv', 'GEIST-MIB-V3'); +$current_oid = '.1.3.6.1.4.1.21239.2.2.1.14.1'; +$descr = 'Voltage'; +discover_sensor($valid['sensor'], 'voltage', $device, $current_oid, 'climateVolts', 'geist-watchdog', $descr, 1, 1, null, null, null, null, $value); diff --git a/includes/polling/os/geist-watchdog.inc.php b/includes/polling/os/geist-watchdog.inc.php new file mode 100644 index 0000000000..f2275c45df --- /dev/null +++ b/includes/polling/os/geist-watchdog.inc.php @@ -0,0 +1,26 @@ +. + * + * @package LibreNMS + * @link http://librenms.org + * @copyright 2017 Neil Lathwood + * @author Neil Lathwood + */ + +$serial = snmp_get($device, 'climateSerial', '-Oqv', 'GEIST-MIB-V3'); diff --git a/mibs/geist/GEIST-MIB-V3 b/mibs/geist/GEIST-MIB-V3 new file mode 100644 index 0000000000..e9e70a17f4 --- /dev/null +++ b/mibs/geist/GEIST-MIB-V3 @@ -0,0 +1,11477 @@ + +GEIST-MIB-V3 DEFINITIONS ::= BEGIN + +IMPORTS + + +DisplayString FROM SNMPv2-TC +MODULE-IDENTITY, OBJECT-TYPE, enterprises, Gauge32, +Integer32, NOTIFICATION-TYPE FROM SNMPv2-SMI; + +geist MODULE-IDENTITY + LAST-UPDATED "201306190000Z" + ORGANIZATION "Geist" + CONTACT-INFO "support@geistglobal.com" + DESCRIPTION "The MIB for Geist Products" + ::= { enterprises 21239 } + +geist OBJECT IDENTIFIER + ::= { enterprises 21239 } + +geistV3 OBJECT IDENTIFIER + ::= { geist 2 } +deviceInfo OBJECT IDENTIFIER + ::= { geistV3 1 } + +productTitle OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Product name" + ::= { deviceInfo 1 } + +productVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Product version" + ::= { deviceInfo 2 } + +productFriendlyName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "User-assigned name" + ::= { deviceInfo 3 } + +productMacAddress OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Product's unique MAC address" + ::= { deviceInfo 4 } + +productUrl OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Product's main URL access point" + ::= { deviceInfo 5 } + +alarmTripType OBJECT-TYPE + SYNTAX INTEGER { none(0), low(1), high(2), unplugged(3) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Type of alarm trip. 0 = None, 1 = Low, 2 = High, 3 = Unplugged" + ::= { deviceInfo 6 } + +productHardware OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Product's hardware type" + ::= { deviceInfo 7 } + +temperaturePrecision OBJECT-TYPE + SYNTAX INTEGER { degree(0), deciDegree(1) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Temperature Precision: + 0 = degree: whole degree (value X 1) + 1 = deci-degree: tenths of a degree (value X 10) + ex. 550 = 55.0 degrees + " + ::= { deviceInfo 9 } + +alarmTrigger OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Used in a trap var-bind to indicate what triggered + the alarm. The alarmTrigger will remain consistent + for both trip and clear traps. Possible values include: + + 'Low' = Low-trip trigger + 'High' = High-trip trigger + 'Unplugged' = Unplugged device trigger + " + ::= { deviceInfo 11 } + +alarmInstance OBJECT-TYPE + SYNTAX INTEGER(1..200) + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Provides the row index (instance number) for the alarm + that generated a trap. This value is only available when + included in the var-binds of an associated trap. " + ::= { deviceInfo 12 } + + +sensorCountsBase OBJECT IDENTIFIER + ::= { deviceInfo 8 } + +sensorCounts OBJECT IDENTIFIER + ::= { sensorCountsBase 1 } + + +climateCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of climate monitors currently plugged in" + ::= { sensorCounts 2 } + +powerMonitorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of power monitors currently plugged in" + ::= { sensorCounts 3 } + +tempSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of temperature sensors currently plugged in" + ::= { sensorCounts 4 } + +airflowSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of airflow sensors currently plugged in" + ::= { sensorCounts 5 } + +ctrl3ChDELTACount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of DELTA 3 channel controllers currently plugged in" + ::= { sensorCounts 6 } + +doorSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of door sensors currently plugged in" + ::= { sensorCounts 7 } + +waterSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of water sensors currently plugged in" + ::= { sensorCounts 8 } + +currentSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of current sensors currently plugged in" + ::= { sensorCounts 9 } + +millivoltSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of millivolt sensors currently plugged in" + ::= { sensorCounts 10 } + +power3ChSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of 3 channel power monitors currently plugged in" + ::= { sensorCounts 11 } + +outletCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of outlets currently plugged in" + ::= { sensorCounts 12 } + +vsfcCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of fan controller monitors currently plugged in" + ::= { sensorCounts 13 } + +ctrl3ChCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of 3 channel controllers currently plugged in" + ::= { sensorCounts 14 } + +ctrlGrpAmpsCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of amperage controllers currently plugged in" + ::= { sensorCounts 15 } + +ctrlOutletCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of monitored or switched outlets" + ::= { sensorCounts 16 } + +dewpointSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of dewpoint sensors currently plugged in" + ::= { sensorCounts 17 } + +digitalSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of digital sensors currently plugged in" + ::= { sensorCounts 18 } + +dstsSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of DSTS controllers currently plugged in" + ::= { sensorCounts 19 } + +cpmSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of city power sensors currently plugged in" + ::= { sensorCounts 20 } + +smokeAlarmSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of smoke alarm sensors currently plugged in" + ::= { sensorCounts 21 } + +neg48VdcSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of -48Vdc sensors currently plugged in" + ::= { sensorCounts 22 } + +pos30VdcSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of 30Vdc sensors currently plugged in" + ::= { sensorCounts 23 } + +analogSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of remote analog inputs currently plugged in" + ::= { sensorCounts 24 } + +ctrl3ChIECCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of IEC 3 channel controllers currently plugged in" + ::= { sensorCounts 25 } + +climateRelayCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of climate relay monitors currently plugged in" + ::= { sensorCounts 26 } + +ctrlRelayCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of relay controllers currently plugged in" + ::= { sensorCounts 27 } + +airSpeedSwitchSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of air speed switch sensors currently plugged in" + ::= { sensorCounts 28 } + +powerDMCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of DM48 current sensors currently plugged in" + ::= { sensorCounts 29 } + +ioExpanderCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of IO expander devices currently plugged in" + ::= { sensorCounts 30 } + +t3hdSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of T3HD sensors currently plugged in" + ::= { sensorCounts 31 } + +thdSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of THD sensors currently plugged in" + ::= { sensorCounts 32 } + +pos60VdcSensorCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of 60Vdc sensors currently plugged in" + ::= { sensorCounts 33 } + +ctrl2CirTotCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of IEC 3 channel controllers currently plugged in" + ::= { sensorCounts 34 } + +sc10Count OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of fan controller monitors currently plugged in" + ::= { sensorCounts 35 } + +climateTable OBJECT-TYPE + SYNTAX SEQUENCE OF ClimateEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Climate sensors (internal sensors for R-Series units)" + ::= { geistV3 2 } + +powMonTable OBJECT-TYPE + SYNTAX SEQUENCE OF PowMonEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of Power Monitors" + ::= { geistV3 3 } + +tempSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF TempSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of temperature sensors" + ::= { geistV3 4 } + +airFlowSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFlowSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of airflow sensors" + ::= { geistV3 5 } + +ctrl3ChDELTATable OBJECT-TYPE + SYNTAX SEQUENCE OF Ctrl3ChDELTAEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of a 3 phase outlet control (DELTA)" + ::= { geistV3 6 } + +doorSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF DoorSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of door sensors" + ::= { geistV3 7 } + +waterSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF WaterSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of water sensors" + ::= { geistV3 8 } + +currentMonitorTable OBJECT-TYPE + SYNTAX SEQUENCE OF CurrentMonitorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of current monitors" + ::= { geistV3 9 } + +millivoltMonitorTable OBJECT-TYPE + SYNTAX SEQUENCE OF MillivoltMonitorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of millivolt monitors" + ::= { geistV3 10 } + +pow3ChTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pow3ChEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of Power Monitor 3 Channel" + ::= { geistV3 11 } + +outletTable OBJECT-TYPE + SYNTAX SEQUENCE OF OutletEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of outlets" + ::= { geistV3 12 } + +vsfcTable OBJECT-TYPE + SYNTAX SEQUENCE OF VsfcEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "VSFC sensors (internal sensors for VSFC units)" + ::= { geistV3 13 } + +ctrl3ChTable OBJECT-TYPE + SYNTAX SEQUENCE OF Ctrl3ChEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of a 3 phase outlet control" + ::= { geistV3 14 } + +ctrlGrpAmpsTable OBJECT-TYPE + SYNTAX SEQUENCE OF CtrlGrpAmpsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of Control Group Amp readings" + ::= { geistV3 15 } + +ctrlOutletTable OBJECT-TYPE + SYNTAX SEQUENCE OF CtrlOutletEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of outlet information" + ::= { geistV3 16 } + +dewPointSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF DewPointSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of dew point sensors" + ::= { geistV3 17 } + +digitalSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF DigitalSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of digital sensors" + ::= { geistV3 18 } + +dstsTable OBJECT-TYPE + SYNTAX SEQUENCE OF DstsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Digital Static Transfer Switch status" + ::= { geistV3 19 } + +cpmSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF CpmSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of city power sensors" + ::= { geistV3 20 } + +smokeAlarmTable OBJECT-TYPE + SYNTAX SEQUENCE OF SmokeAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of smoke alarm sensors" + ::= { geistV3 21 } + +neg48VdcSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF Neg48VdcSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of -48Vdc sensors" + ::= { geistV3 22 } + +pos30VdcSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pos30VdcSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of 30Vdc sensors" + ::= { geistV3 23 } + +analogSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF AnalogSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of analog sensors" + ::= { geistV3 24 } + +ctrl3ChIECTable OBJECT-TYPE + SYNTAX SEQUENCE OF Ctrl3ChIECEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of a 3 phase outlet control (IEC)" + ::= { geistV3 25 } + +climateRelayTable OBJECT-TYPE + SYNTAX SEQUENCE OF ClimateRelayEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Climate Relay sensors (internal sensors for R-Series Relay units)" + ::= { geistV3 26 } + +ctrlRelayTable OBJECT-TYPE + SYNTAX SEQUENCE OF CtrlRelayEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of relay information" + ::= { geistV3 27 } + +airSpeedSwitchSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirSpeedSwitchSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of air speed switch sensors" + ::= { geistV3 28 } + +powerDMTable OBJECT-TYPE + SYNTAX SEQUENCE OF PowerDMEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of DM48 current monitors" + ::= { geistV3 29 } + +ioExpanderTable OBJECT-TYPE + SYNTAX SEQUENCE OF IoExpanderEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "IO Expander device with relay capability" + ::= { geistV3 30 } + +t3hdSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF T3hdSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of T3HD sensors" + ::= { geistV3 31 } + +thdSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF ThdSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of THD sensors" + ::= { geistV3 32 } + +pos60VdcSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF Pos60VdcSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of 60Vdc sensors" + ::= { geistV3 33 } + +ctrl2CirTotTable OBJECT-TYPE + SYNTAX SEQUENCE OF Ctrl2CirTotEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "A table of a 3 phase outlet control (IEC)" + ::= { geistV3 34 } + +sc10Table OBJECT-TYPE + SYNTAX SEQUENCE OF Sc10Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "SC10 sensors (internal measurements for SC10 units)" + ::= { geistV3 35 } + +climateEntry OBJECT-TYPE + SYNTAX ClimateEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the climate table: each entry contains +an index (climateIndex) and other power strip details" + INDEX { climateIndex } + ::= { climateTable 1 } + +ClimateEntry ::= SEQUENCE { + climateIndex INTEGER, + climateSerial DisplayString, + climateName DisplayString, + climateAvail Gauge32, + climateTempC INTEGER, + climateTempF INTEGER, + climateHumidity INTEGER, + climateLight INTEGER, + climateAirflow INTEGER, + climateSound INTEGER, + climateIO1 INTEGER, + climateIO2 INTEGER, + climateIO3 INTEGER, + climateVolts Gauge32, + climateVoltPeak Gauge32, + climateDeciAmpsA Gauge32, + climateDeciAmpPeakA Gauge32, + climateRealPowerA Gauge32, + climateApparentPowerA Gauge32, + climatePowerFactorA Gauge32, + climateDeciAmpsB Gauge32, + climateDeciAmpPeakB Gauge32, + climateRealPowerB Gauge32, + climateApparentPowerB Gauge32, + climatePowerFactorB Gauge32, + climateDeciAmpsC Gauge32, + climateDeciAmpPeakC Gauge32, + climateRealPowerC Gauge32, + climateApparentPowerC Gauge32, + climatePowerFactorC Gauge32, + climateDewPointC INTEGER, + climateDewPointF INTEGER +} + +climateIndex OBJECT-TYPE + SYNTAX INTEGER(1..1) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { climateEntry 1 } + +climateSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { climateEntry 2 } + +climateName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { climateEntry 3 } + +climateAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { climateEntry 4 } + +climateTempC OBJECT-TYPE + SYNTAX INTEGER(-50..100) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Temperature (C)" + ::= { climateEntry 5 } + +climateTempF OBJECT-TYPE + SYNTAX INTEGER(-58..212) + UNITS "Degress Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Temperature (F)" + ::= { climateEntry 6 } + +climateHumidity OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Humidity" + ::= { climateEntry 7 } + +climateLight OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Ambient Light" + ::= { climateEntry 8 } + +climateAirflow OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Airflow" + ::= { climateEntry 9 } + +climateSound OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Sound" + ::= { climateEntry 10 } + +climateIO1 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 1" + ::= { climateEntry 11 } + +climateIO2 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 2" + ::= { climateEntry 12 } + +climateIO3 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 3" + ::= { climateEntry 13 } + +climateVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts" + ::= { climateEntry 14 } + +climateVoltPeak OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Volts" + ::= { climateEntry 15 } + +climateDeciAmpsA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Amps (Phase A)" + ::= { climateEntry 16 } + +climateDeciAmpPeakA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Amps (Phase A)" + ::= { climateEntry 17 } + +climateRealPowerA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Phase A)" + ::= { climateEntry 18 } + +climateApparentPowerA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Apparent Power (Phase A)" + ::= { climateEntry 19 } + +climatePowerFactorA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Phase A)" + ::= { climateEntry 20 } + +climateDeciAmpsB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Amps (Phase B)" + ::= { climateEntry 21 } + +climateDeciAmpPeakB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Amps (Phase B)" + ::= { climateEntry 22 } + +climateRealPowerB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Phase B)" + ::= { climateEntry 23 } + +climateApparentPowerB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Apparent Power (Phase B)" + ::= { climateEntry 24 } + +climatePowerFactorB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Phase B)" + ::= { climateEntry 25 } + +climateDeciAmpsC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Amps (Phase C)" + ::= { climateEntry 26 } + +climateDeciAmpPeakC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Amps (Phase C)" + ::= { climateEntry 27 } + +climateRealPowerC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Phase C)" + ::= { climateEntry 28 } + +climateApparentPowerC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Apparent Power (Phase C)" + ::= { climateEntry 29 } + +climatePowerFactorC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Phase C)" + ::= { climateEntry 30 } + +climateDewPointC OBJECT-TYPE + SYNTAX INTEGER(-50..100) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Dew Point (C)" + ::= { climateEntry 31 } + +climateDewPointF OBJECT-TYPE + SYNTAX INTEGER(-58..212) + UNITS "Degress Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Dew Point (F)" + ::= { climateEntry 32 } + +powMonEntry OBJECT-TYPE + SYNTAX PowMonEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the power monitor table: each entry contains +an index (powMonIndex) and other power monitoring details" + INDEX { powMonIndex } + ::= { powMonTable 1 } + +PowMonEntry ::= SEQUENCE { + powMonIndex INTEGER, + powMonSerial DisplayString, + powMonName DisplayString, + powMonAvail Gauge32, + powMonkWattHrs Gauge32, + powMonVolts Gauge32, + powMonVoltMax Gauge32, + powMonVoltMin Gauge32, + powMonVoltPeak Gauge32, + powMonDeciAmps Gauge32, + powMonRealPower Gauge32, + powMonApparentPower Gauge32, + powMonPowerFactor INTEGER, + powMonOutlet1 INTEGER, + powMonOutlet2 INTEGER, + powMonOutlet1StatusTime Gauge32, + powMonOutlet2StatusTime Gauge32 +} + +powMonIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { powMonEntry 1 } + +powMonSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { powMonEntry 2 } + +powMonName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { powMonEntry 3 } + +powMonAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { powMonEntry 4 } + +powMonkWattHrs OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for kWatt-Hours" + ::= { powMonEntry 5 } + +powMonVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts" + ::= { powMonEntry 6 } + +powMonVoltMax OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Max)" + ::= { powMonEntry 7 } + +powMonVoltMin OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Min)" + ::= { powMonEntry 8 } + +powMonVoltPeak OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Peak)" + ::= { powMonEntry 9 } + +powMonDeciAmps OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for DeciAmps" + ::= { powMonEntry 10 } + +powMonRealPower OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power" + ::= { powMonEntry 11 } + +powMonApparentPower OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Apparent Power" + ::= { powMonEntry 12 } + +powMonPowerFactor OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor" + ::= { powMonEntry 13 } + +powMonOutlet1 OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "Outlet 1" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Outlet 1 Trap" + ::= { powMonEntry 14 } + +powMonOutlet2 OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "Outlet 2" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Outlet 2 Trap" + ::= { powMonEntry 15 } + +powMonOutlet1StatusTime OBJECT-TYPE + SYNTAX Gauge32 + UNITS "seconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Seconds Since Outlet 1 Last Changed Its Status" + ::= { powMonEntry 16 } + +powMonOutlet2StatusTime OBJECT-TYPE + SYNTAX Gauge32 + UNITS "seconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Seconds Since Outlet 2 Last Changed Its Status" + ::= { powMonEntry 17 } + +tempSensorEntry OBJECT-TYPE + SYNTAX TempSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the temperature sensor table: each entry contains +an index (tempIndex) and other sensor details" + INDEX { tempSensorIndex } + ::= { tempSensorTable 1 } + +TempSensorEntry ::= SEQUENCE { + tempSensorIndex INTEGER, + tempSensorSerial DisplayString, + tempSensorName DisplayString, + tempSensorAvail Gauge32, + tempSensorTempC INTEGER, + tempSensorTempF INTEGER +} + +tempSensorIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { tempSensorEntry 1 } + +tempSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { tempSensorEntry 2 } + +tempSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { tempSensorEntry 3 } + +tempSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { tempSensorEntry 4 } + +tempSensorTempC OBJECT-TYPE + SYNTAX INTEGER(-50..100) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Temperature in Celsius" + ::= { tempSensorEntry 5 } + +tempSensorTempF OBJECT-TYPE + SYNTAX INTEGER(-58..212) + UNITS "Degrees Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Temperature in Fahrenheit" + ::= { tempSensorEntry 6 } + +airFlowSensorEntry OBJECT-TYPE + SYNTAX AirFlowSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the air flow sensor table: each entry contains +an index (airFlowSensorIndex) and other sensor details" + INDEX { airFlowSensorIndex } + ::= { airFlowSensorTable 1 } + +AirFlowSensorEntry ::= SEQUENCE { + airFlowSensorIndex INTEGER, + airFlowSensorSerial DisplayString, + airFlowSensorName DisplayString, + airFlowSensorAvail Gauge32, + airFlowSensorTempC INTEGER, + airFlowSensorTempF INTEGER, + airFlowSensorFlow INTEGER, + airFlowSensorHumidity INTEGER, + airFlowSensorDewPointC INTEGER, + airFlowSensorDewPointF INTEGER +} + +airFlowSensorIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { airFlowSensorEntry 1 } + +airFlowSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { airFlowSensorEntry 2 } + +airFlowSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { airFlowSensorEntry 3 } + +airFlowSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { airFlowSensorEntry 4 } + +airFlowSensorTempC OBJECT-TYPE + SYNTAX INTEGER(-50..100) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Temperature reading in C" + ::= { airFlowSensorEntry 5 } + +airFlowSensorTempF OBJECT-TYPE + SYNTAX INTEGER(-58..212) + UNITS "Degrees Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Temperature reading in F" + ::= { airFlowSensorEntry 6 } + +airFlowSensorFlow OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Air flow reading" + ::= { airFlowSensorEntry 7 } + +airFlowSensorHumidity OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Humidity reading" + ::= { airFlowSensorEntry 8 } + +airFlowSensorDewPointC OBJECT-TYPE + SYNTAX INTEGER(-50..100) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Dew Point (C)" + ::= { airFlowSensorEntry 9 } + +airFlowSensorDewPointF OBJECT-TYPE + SYNTAX INTEGER(-58..212) + UNITS "Degress Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Dew Point (F)" + ::= { airFlowSensorEntry 10 } + +ctrl3ChDELTAEntry OBJECT-TYPE + SYNTAX Ctrl3ChDELTAEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the 3 phase delta outlet control table: each entry contains +an index (ctrl3ChDELTAIndex) and other outlet control monitoring details" + INDEX { ctrl3ChDELTAIndex } + ::= { ctrl3ChDELTATable 1 } + +Ctrl3ChDELTAEntry ::= SEQUENCE { + ctrl3ChDELTAIndex INTEGER, + ctrl3ChDELTASerial DisplayString, + ctrl3ChDELTAName DisplayString, + ctrl3ChDELTAAvail Gauge32, + ctrl3ChDELTAPowerChCount INTEGER, + ctrl3ChDELTADeciAmpsA Gauge32, + ctrl3ChDELTADeciAmpsB Gauge32, + ctrl3ChDELTADeciAmpsC Gauge32, + ctrl3ChDELTAkWattHrsTotal Gauge32, + ctrl3ChDELTARealPowerTotal Gauge32, + ctrl3ChDELTAkWattHrsAB Gauge32, + ctrl3ChDELTAVoltsAB Gauge32, + ctrl3ChDELTAVoltPeakAB Gauge32, + ctrl3ChDELTARealPowerAB Gauge32, + ctrl3ChDELTAApparentPowerAB Gauge32, + ctrl3ChDELTAPowerFactorAB INTEGER, + ctrl3ChDELTAkWattHrsBC Gauge32, + ctrl3ChDELTAVoltsBC Gauge32, + ctrl3ChDELTAVoltPeakBC Gauge32, + ctrl3ChDELTARealPowerBC Gauge32, + ctrl3ChDELTAApparentPowerBC Gauge32, + ctrl3ChDELTAPowerFactorBC INTEGER, + ctrl3ChDELTAkWattHrsCA Gauge32, + ctrl3ChDELTAVoltsCA Gauge32, + ctrl3ChDELTAVoltPeakCA Gauge32, + ctrl3ChDELTARealPowerCA Gauge32, + ctrl3ChDELTAApparentPowerCA Gauge32, + ctrl3ChDELTAPowerFactorCA INTEGER +} + +ctrl3ChDELTAIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { ctrl3ChDELTAEntry 1 } + +ctrl3ChDELTASerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { ctrl3ChDELTAEntry 2 } + +ctrl3ChDELTAName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { ctrl3ChDELTAEntry 3 } + +ctrl3ChDELTAAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { ctrl3ChDELTAEntry 4 } + +ctrl3ChDELTAPowerChCount OBJECT-TYPE + SYNTAX INTEGER(0..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of active power channels" + ::= { ctrl3ChDELTAEntry 5 } + +ctrl3ChDELTADeciAmpsA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for DeciAmps (Line A)" + ::= { ctrl3ChDELTAEntry 6 } + +ctrl3ChDELTADeciAmpsB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for DeciAmps (Line B)" + ::= { ctrl3ChDELTAEntry 7 } + +ctrl3ChDELTADeciAmpsC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for DeciAmps (Line C)" + ::= { ctrl3ChDELTAEntry 8 } + +ctrl3ChDELTAkWattHrsTotal OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Reading for kWatt-Hours (Total)" + ::= { ctrl3ChDELTAEntry 9 } + +ctrl3ChDELTARealPowerTotal OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Watts (Total)" + ::= { ctrl3ChDELTAEntry 10 } + +ctrl3ChDELTAkWattHrsAB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Reading for kWatt-Hours (Phase AB)" + ::= { ctrl3ChDELTAEntry 11 } + +ctrl3ChDELTAVoltsAB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Phase AB)" + ::= { ctrl3ChDELTAEntry 12 } + +ctrl3ChDELTAVoltPeakAB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Volts (Phase AB)" + ::= { ctrl3ChDELTAEntry 13 } + +ctrl3ChDELTARealPowerAB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Phase AB)" + ::= { ctrl3ChDELTAEntry 14 } + +ctrl3ChDELTAApparentPowerAB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for VoltAmps (Phase AB)" + ::= { ctrl3ChDELTAEntry 15 } + +ctrl3ChDELTAPowerFactorAB OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Phase AB)" + ::= { ctrl3ChDELTAEntry 16 } + +ctrl3ChDELTAkWattHrsBC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Reading for kWatt-Hours (Phase BC)" + ::= { ctrl3ChDELTAEntry 17 } + +ctrl3ChDELTAVoltsBC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Phase BC)" + ::= { ctrl3ChDELTAEntry 18 } + +ctrl3ChDELTAVoltPeakBC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Volts (Phase BC)" + ::= { ctrl3ChDELTAEntry 19 } + +ctrl3ChDELTARealPowerBC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Phase BC)" + ::= { ctrl3ChDELTAEntry 20 } + +ctrl3ChDELTAApparentPowerBC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for VoltAmps (Phase BC)" + ::= { ctrl3ChDELTAEntry 21 } + +ctrl3ChDELTAPowerFactorBC OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Phase BC)" + ::= { ctrl3ChDELTAEntry 22 } + +ctrl3ChDELTAkWattHrsCA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Reading for kWatt-Hours (Phase CA)" + ::= { ctrl3ChDELTAEntry 23 } + +ctrl3ChDELTAVoltsCA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Phase CA)" + ::= { ctrl3ChDELTAEntry 24 } + +ctrl3ChDELTAVoltPeakCA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Volts (Phase CA)" + ::= { ctrl3ChDELTAEntry 25 } + +ctrl3ChDELTARealPowerCA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Phase CA)" + ::= { ctrl3ChDELTAEntry 26 } + +ctrl3ChDELTAApparentPowerCA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for VoltAmps (Phase CA)" + ::= { ctrl3ChDELTAEntry 27 } + +ctrl3ChDELTAPowerFactorCA OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Phase CA)" + ::= { ctrl3ChDELTAEntry 28 } + +doorSensorEntry OBJECT-TYPE + SYNTAX DoorSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the door sensor table: each entry contains +an index (doorSensorIndex) and other sensor details" + INDEX { doorSensorIndex } + ::= { doorSensorTable 1 } + +DoorSensorEntry ::= SEQUENCE { + doorSensorIndex INTEGER, + doorSensorSerial DisplayString, + doorSensorName DisplayString, + doorSensorAvail Gauge32, + doorSensorStatus INTEGER +} + +doorSensorIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { doorSensorEntry 1 } + +doorSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { doorSensorEntry 2 } + +doorSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { doorSensorEntry 3 } + +doorSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { doorSensorEntry 4 } + +doorSensorStatus OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Door sensor status" + ::= { doorSensorEntry 5 } + +waterSensorEntry OBJECT-TYPE + SYNTAX WaterSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the water sensor table: each entry contains +an index (waterSensorIndex) and other sensor details" + INDEX { waterSensorIndex } + ::= { waterSensorTable 1 } + +WaterSensorEntry ::= SEQUENCE { + waterSensorIndex INTEGER, + waterSensorSerial DisplayString, + waterSensorName DisplayString, + waterSensorAvail Gauge32, + waterSensorDampness INTEGER +} + +waterSensorIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { waterSensorEntry 1 } + +waterSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { waterSensorEntry 2 } + +waterSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { waterSensorEntry 3 } + +waterSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { waterSensorEntry 4 } + +waterSensorDampness OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Dampness of the water sensor" + ::= { waterSensorEntry 5 } + +currentMonitorEntry OBJECT-TYPE + SYNTAX CurrentMonitorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the current monitor table: each entry contains +an index (currentMonitorIndex) and other sensor details" + INDEX { currentMonitorIndex } + ::= { currentMonitorTable 1 } + +CurrentMonitorEntry ::= SEQUENCE { + currentMonitorIndex INTEGER, + currentMonitorSerial DisplayString, + currentMonitorName DisplayString, + currentMonitorAvail Gauge32, + currentMonitorDeciAmps INTEGER +} + +currentMonitorIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { currentMonitorEntry 1 } + +currentMonitorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { currentMonitorEntry 2 } + +currentMonitorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { currentMonitorEntry 3 } + +currentMonitorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { currentMonitorEntry 4 } + +currentMonitorDeciAmps OBJECT-TYPE + SYNTAX INTEGER(0..30) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { currentMonitorEntry 5 } + +millivoltMonitorEntry OBJECT-TYPE + SYNTAX MillivoltMonitorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the millivolt monitor table: each entry contains +an index (millivoltMonitorIndex) and other sensor details" + INDEX { millivoltMonitorIndex } + ::= { millivoltMonitorTable 1 } + +MillivoltMonitorEntry ::= SEQUENCE { + millivoltMonitorIndex INTEGER, + millivoltMonitorSerial DisplayString, + millivoltMonitorName DisplayString, + millivoltMonitorAvail Gauge32, + millivoltMonitorMV INTEGER +} + +millivoltMonitorIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { millivoltMonitorEntry 1 } + +millivoltMonitorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { millivoltMonitorEntry 2 } + +millivoltMonitorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { millivoltMonitorEntry 3 } + +millivoltMonitorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { millivoltMonitorEntry 4 } + +millivoltMonitorMV OBJECT-TYPE + SYNTAX INTEGER(0..5000) + UNITS "millivolts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "millivolts" + ::= { millivoltMonitorEntry 5 } + +pow3ChEntry OBJECT-TYPE + SYNTAX Pow3ChEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the power monitor 3 channel table: each entry contains +an index (pow3ChIndex) and other power monitoring details" + INDEX { pow3ChIndex } + ::= { pow3ChTable 1 } + +Pow3ChEntry ::= SEQUENCE { + pow3ChIndex INTEGER, + pow3ChSerial DisplayString, + pow3ChName DisplayString, + pow3ChAvail Gauge32, + pow3ChkWattHrsA Gauge32, + pow3ChVoltsA Gauge32, + pow3ChVoltMaxA Gauge32, + pow3ChVoltMinA Gauge32, + pow3ChVoltPeakA Gauge32, + pow3ChDeciAmpsA Gauge32, + pow3ChRealPowerA Gauge32, + pow3ChApparentPowerA Gauge32, + pow3ChPowerFactorA INTEGER, + pow3ChkWattHrsB Gauge32, + pow3ChVoltsB Gauge32, + pow3ChVoltMaxB Gauge32, + pow3ChVoltMinB Gauge32, + pow3ChVoltPeakB Gauge32, + pow3ChDeciAmpsB Gauge32, + pow3ChRealPowerB Gauge32, + pow3ChApparentPowerB Gauge32, + pow3ChPowerFactorB INTEGER, + pow3ChkWattHrsC Gauge32, + pow3ChVoltsC Gauge32, + pow3ChVoltMaxC Gauge32, + pow3ChVoltMinC Gauge32, + pow3ChVoltPeakC Gauge32, + pow3ChDeciAmpsC Gauge32, + pow3ChRealPowerC Gauge32, + pow3ChApparentPowerC Gauge32, + pow3ChPowerFactorC INTEGER, + pow3ChkWattHrsTotal Gauge32, + pow3ChRealPowerTotal Gauge32 +} + +pow3ChIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { pow3ChEntry 1 } + +pow3ChSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { pow3ChEntry 2 } + +pow3ChName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { pow3ChEntry 3 } + +pow3ChAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { pow3ChEntry 4 } + +pow3ChkWattHrsA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for kWatt-Hours (Phase A)" + ::= { pow3ChEntry 5 } + +pow3ChVoltsA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Phase A)" + ::= { pow3ChEntry 6 } + +pow3ChVoltMaxA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Max-Volts (Phase A)" + ::= { pow3ChEntry 7 } + +pow3ChVoltMinA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Min-Volts (Phase A)" + ::= { pow3ChEntry 8 } + +pow3ChVoltPeakA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Volts (Phase A)" + ::= { pow3ChEntry 9 } + +pow3ChDeciAmpsA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for DeciAmps (Phase A)" + ::= { pow3ChEntry 10 } + +pow3ChRealPowerA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Phase A)" + ::= { pow3ChEntry 11 } + +pow3ChApparentPowerA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Apparent Power (Phase A)" + ::= { pow3ChEntry 12 } + +pow3ChPowerFactorA OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Phase A)" + ::= { pow3ChEntry 13 } + +pow3ChkWattHrsB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for kWatt-Hours (Phase B)" + ::= { pow3ChEntry 14 } + +pow3ChVoltsB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Phase B)" + ::= { pow3ChEntry 15 } + +pow3ChVoltMaxB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Max-Volts (Phase B)" + ::= { pow3ChEntry 16 } + +pow3ChVoltMinB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Min-Volts (Phase B)" + ::= { pow3ChEntry 17 } + +pow3ChVoltPeakB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Volts (Phase B)" + ::= { pow3ChEntry 18 } + +pow3ChDeciAmpsB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for DeciAmps (Phase B)" + ::= { pow3ChEntry 19 } + +pow3ChRealPowerB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Phase B)" + ::= { pow3ChEntry 20 } + +pow3ChApparentPowerB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Apparent Power (Phase B)" + ::= { pow3ChEntry 21 } + +pow3ChPowerFactorB OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Phase B)" + ::= { pow3ChEntry 22 } + +pow3ChkWattHrsC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for kWatt-Hours (Phase C)" + ::= { pow3ChEntry 23 } + +pow3ChVoltsC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Phase C)" + ::= { pow3ChEntry 24 } + +pow3ChVoltMaxC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Max-Volts (Phase C)" + ::= { pow3ChEntry 25 } + +pow3ChVoltMinC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Min-Volts (Phase C)" + ::= { pow3ChEntry 26 } + +pow3ChVoltPeakC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Volts (Phase C)" + ::= { pow3ChEntry 27 } + +pow3ChDeciAmpsC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for DeciAmps (Phase C)" + ::= { pow3ChEntry 28 } + +pow3ChRealPowerC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Phase C)" + ::= { pow3ChEntry 29 } + +pow3ChApparentPowerC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Apparent Power (Phase C)" + ::= { pow3ChEntry 30 } + +pow3ChPowerFactorC OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Phase C)" + ::= { pow3ChEntry 31 } + +pow3ChkWattHrsTotal OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for kWatt-Hours (Total)" + ::= { pow3ChEntry 32 } + +pow3ChRealPowerTotal OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Total)" + ::= { pow3ChEntry 33 } + +outletEntry OBJECT-TYPE + SYNTAX OutletEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the outlet table: each entry contains +an index (outletIndex) and other sensor details" + INDEX { outletIndex } + ::= { outletTable 1 } + +OutletEntry ::= SEQUENCE { + outletIndex INTEGER, + outletSerial DisplayString, + outletName DisplayString, + outletAvail Gauge32, + outlet1Status INTEGER, + outlet2Status INTEGER +} + +outletIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { outletEntry 1 } + +outletSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { outletEntry 2 } + +outletName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { outletEntry 3 } + +outletAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { outletEntry 4 } + +outlet1Status OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Outlet 1 status" + ::= { outletEntry 5 } + +outlet2Status OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Outlet 2 status" + ::= { outletEntry 6 } + +vsfcEntry OBJECT-TYPE + SYNTAX VsfcEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the vsfc table: each entry contains +an index (vsfcIndex) and other details" + INDEX { vsfcIndex } + ::= { vsfcTable 1 } + +VsfcEntry ::= SEQUENCE { + vsfcIndex INTEGER, + vsfcSerial DisplayString, + vsfcName DisplayString, + vsfcAvail Gauge32, + vsfcSetPointC INTEGER, + vsfcSetPointF INTEGER, + vsfcFanSpeed INTEGER, + vsfcIntTempC INTEGER, + vsfcIntTempF INTEGER, + vsfcExt1TempC INTEGER, + vsfcExt1TempF INTEGER, + vsfcExt2TempC INTEGER, + vsfcExt2TempF INTEGER, + vsfcExt3TempC INTEGER, + vsfcExt3TempF INTEGER, + vsfcExt4TempC INTEGER, + vsfcExt4TempF INTEGER +} + +vsfcIndex OBJECT-TYPE + SYNTAX INTEGER(1..1) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { vsfcEntry 1 } + +vsfcSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { vsfcEntry 2 } + +vsfcName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { vsfcEntry 3 } + +vsfcAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { vsfcEntry 4 } + +vsfcSetPointC OBJECT-TYPE + SYNTAX INTEGER(18..38) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current temperature set point in C" + ::= { vsfcEntry 5 } + +vsfcSetPointF OBJECT-TYPE + SYNTAX INTEGER(65..100) + UNITS "Degrees Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current temperature set point in F" + ::= { vsfcEntry 6 } + +vsfcFanSpeed OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Fan Speed" + ::= { vsfcEntry 7 } + +vsfcIntTempC OBJECT-TYPE + SYNTAX INTEGER(-20..50) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current internal temperature reading in C" + ::= { vsfcEntry 8 } + +vsfcIntTempF OBJECT-TYPE + SYNTAX INTEGER(-4..122) + UNITS "Degrees Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current internal temperature reading in F" + ::= { vsfcEntry 9 } + +vsfcExt1TempC OBJECT-TYPE + SYNTAX INTEGER(-20..50) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for external temp 1 in C" + ::= { vsfcEntry 10 } + +vsfcExt1TempF OBJECT-TYPE + SYNTAX INTEGER(-20..122) + UNITS "Degrees Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for external temp 1 in F" + ::= { vsfcEntry 11 } + +vsfcExt2TempC OBJECT-TYPE + SYNTAX INTEGER(-20..50) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for external temp 2 in C" + ::= { vsfcEntry 12 } + +vsfcExt2TempF OBJECT-TYPE + SYNTAX INTEGER(-20..122) + UNITS "Degrees Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for external temp 1 in F" + ::= { vsfcEntry 13 } + +vsfcExt3TempC OBJECT-TYPE + SYNTAX INTEGER(-20..50) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for external temp 3 in C" + ::= { vsfcEntry 14 } + +vsfcExt3TempF OBJECT-TYPE + SYNTAX INTEGER(-20..122) + UNITS "Degrees Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for external temp 1 in F" + ::= { vsfcEntry 15 } + +vsfcExt4TempC OBJECT-TYPE + SYNTAX INTEGER(-20..50) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for external temp 4 in C" + ::= { vsfcEntry 16 } + +vsfcExt4TempF OBJECT-TYPE + SYNTAX INTEGER(-20..122) + UNITS "Degrees Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for external temp 1 in F" + ::= { vsfcEntry 17 } + +ctrl3ChEntry OBJECT-TYPE + SYNTAX Ctrl3ChEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the 3 phase outlet control table: each entry contains +an index (ctrl3ChIndex) and other outlet control monitoring details" + INDEX { ctrl3ChIndex } + ::= { ctrl3ChTable 1 } + +Ctrl3ChEntry ::= SEQUENCE { + ctrl3ChIndex INTEGER, + ctrl3ChSerial DisplayString, + ctrl3ChName DisplayString, + ctrl3ChAvail Gauge32, + ctrl3ChVoltsA Gauge32, + ctrl3ChVoltPeakA Gauge32, + ctrl3ChDeciAmpsA Gauge32, + ctrl3ChDeciAmpsPeakA Gauge32, + ctrl3ChRealPowerA Gauge32, + ctrl3ChApparentPowerA Gauge32, + ctrl3ChPowerFactorA INTEGER, + ctrl3ChVoltsB Gauge32, + ctrl3ChVoltPeakB Gauge32, + ctrl3ChDeciAmpsB Gauge32, + ctrl3ChDeciAmpsPeakB Gauge32, + ctrl3ChRealPowerB Gauge32, + ctrl3ChApparentPowerB Gauge32, + ctrl3ChPowerFactorB INTEGER, + ctrl3ChVoltsC Gauge32, + ctrl3ChVoltPeakC Gauge32, + ctrl3ChDeciAmpsC Gauge32, + ctrl3ChDeciAmpsPeakC Gauge32, + ctrl3ChRealPowerC Gauge32, + ctrl3ChApparentPowerC Gauge32, + ctrl3ChPowerFactorC INTEGER +} + +ctrl3ChIndex OBJECT-TYPE + SYNTAX INTEGER(1..1) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { ctrl3ChEntry 1 } + +ctrl3ChSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { ctrl3ChEntry 2 } + +ctrl3ChName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { ctrl3ChEntry 3 } + +ctrl3ChAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { ctrl3ChEntry 4 } + +ctrl3ChVoltsA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Phase A)" + ::= { ctrl3ChEntry 5 } + +ctrl3ChVoltPeakA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Volts (Phase A)" + ::= { ctrl3ChEntry 6 } + +ctrl3ChDeciAmpsA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for DeciAmps (Phase A)" + ::= { ctrl3ChEntry 7 } + +ctrl3ChDeciAmpsPeakA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-DeciAmps (Phase A)" + ::= { ctrl3ChEntry 8 } + +ctrl3ChRealPowerA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Phase A)" + ::= { ctrl3ChEntry 9 } + +ctrl3ChApparentPowerA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Apparent Power (Phase A)" + ::= { ctrl3ChEntry 10 } + +ctrl3ChPowerFactorA OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Phase A)" + ::= { ctrl3ChEntry 11 } + +ctrl3ChVoltsB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Phase B)" + ::= { ctrl3ChEntry 12 } + +ctrl3ChVoltPeakB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Volts (Phase B)" + ::= { ctrl3ChEntry 13 } + +ctrl3ChDeciAmpsB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for DeciAmps (Phase B)" + ::= { ctrl3ChEntry 14 } + +ctrl3ChDeciAmpsPeakB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-DeciAmps (Phase B)" + ::= { ctrl3ChEntry 15 } + +ctrl3ChRealPowerB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Phase B)" + ::= { ctrl3ChEntry 16 } + +ctrl3ChApparentPowerB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Apparent Power (Phase B)" + ::= { ctrl3ChEntry 17 } + +ctrl3ChPowerFactorB OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Phase B)" + ::= { ctrl3ChEntry 18 } + +ctrl3ChVoltsC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Phase C)" + ::= { ctrl3ChEntry 19 } + +ctrl3ChVoltPeakC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Volts (Phase C)" + ::= { ctrl3ChEntry 20 } + +ctrl3ChDeciAmpsC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for DeciAmps (Phase C)" + ::= { ctrl3ChEntry 21 } + +ctrl3ChDeciAmpsPeakC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-DeciAmps (Phase C)" + ::= { ctrl3ChEntry 22 } + +ctrl3ChRealPowerC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Phase C)" + ::= { ctrl3ChEntry 23 } + +ctrl3ChApparentPowerC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Apparent Power (Phase C)" + ::= { ctrl3ChEntry 24 } + +ctrl3ChPowerFactorC OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Phase C)" + ::= { ctrl3ChEntry 25 } + +ctrlGrpAmpsEntry OBJECT-TYPE + SYNTAX CtrlGrpAmpsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the Control Group Amps table: each entry contains +an index (ctrlGrpAmpsIndex) and other sensor details" + INDEX { ctrlGrpAmpsIndex } + ::= { ctrlGrpAmpsTable 1 } + +CtrlGrpAmpsEntry ::= SEQUENCE { + ctrlGrpAmpsIndex INTEGER, + ctrlGrpAmpsSerial DisplayString, + ctrlGrpAmpsName DisplayString, + ctrlGrpAmpsAvail Gauge32, + ctrlGrpAmpsA Gauge32, + ctrlGrpAmpsB Gauge32, + ctrlGrpAmpsC Gauge32, + ctrlGrpAmpsD Gauge32, + ctrlGrpAmpsE Gauge32, + ctrlGrpAmpsF Gauge32, + ctrlGrpAmpsG Gauge32, + ctrlGrpAmpsH Gauge32, + ctrlGrpAmpsAVolts Gauge32, + ctrlGrpAmpsBVolts Gauge32, + ctrlGrpAmpsCVolts Gauge32, + ctrlGrpAmpsDVolts Gauge32, + ctrlGrpAmpsEVolts Gauge32, + ctrlGrpAmpsFVolts Gauge32, + ctrlGrpAmpsGVolts Gauge32, + ctrlGrpAmpsHVolts Gauge32, + ctrlGrpAmpsI Gauge32, + ctrlGrpAmpsJ Gauge32, + ctrlGrpAmpsK Gauge32, + ctrlGrpAmpsL Gauge32, + ctrlGrpAmpsM Gauge32, + ctrlGrpAmpsN Gauge32, + ctrlGrpAmpsO Gauge32, + ctrlGrpAmpsP Gauge32, + ctrlGrpAmpsIVolts Gauge32, + ctrlGrpAmpsJVolts Gauge32, + ctrlGrpAmpsKVolts Gauge32, + ctrlGrpAmpsLVolts Gauge32, + ctrlGrpAmpsMVolts Gauge32, + ctrlGrpAmpsNVolts Gauge32, + ctrlGrpAmpsOVolts Gauge32, + ctrlGrpAmpsPVolts Gauge32 +} + +ctrlGrpAmpsIndex OBJECT-TYPE + SYNTAX INTEGER(1..1) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { ctrlGrpAmpsEntry 1 } + +ctrlGrpAmpsSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { ctrlGrpAmpsEntry 2 } + +ctrlGrpAmpsName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { ctrlGrpAmpsEntry 3 } + +ctrlGrpAmpsAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { ctrlGrpAmpsEntry 4 } + +ctrlGrpAmpsA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DeciAmps Group A" + ::= { ctrlGrpAmpsEntry 5 } + +ctrlGrpAmpsB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DeciAmps Group B" + ::= { ctrlGrpAmpsEntry 6 } + +ctrlGrpAmpsC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DeciAmps Group C" + ::= { ctrlGrpAmpsEntry 7 } + +ctrlGrpAmpsD OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DeciAmps Group D" + ::= { ctrlGrpAmpsEntry 8 } + +ctrlGrpAmpsE OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DeciAmps Group E" + ::= { ctrlGrpAmpsEntry 9 } + +ctrlGrpAmpsF OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DeciAmps Group F" + ::= { ctrlGrpAmpsEntry 10 } + +ctrlGrpAmpsG OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DeciAmps Group G" + ::= { ctrlGrpAmpsEntry 11 } + +ctrlGrpAmpsH OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DeciAmps Group H" + ::= { ctrlGrpAmpsEntry 12 } + +ctrlGrpAmpsAVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Volts Group A" + ::= { ctrlGrpAmpsEntry 13 } + +ctrlGrpAmpsBVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Volts Group B" + ::= { ctrlGrpAmpsEntry 14 } + +ctrlGrpAmpsCVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Volts Group C" + ::= { ctrlGrpAmpsEntry 15 } + +ctrlGrpAmpsDVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Volts Group D" + ::= { ctrlGrpAmpsEntry 16 } + +ctrlGrpAmpsEVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Volts Group E" + ::= { ctrlGrpAmpsEntry 17 } + +ctrlGrpAmpsFVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Volts Group F" + ::= { ctrlGrpAmpsEntry 18 } + +ctrlGrpAmpsGVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Volts Group G" + ::= { ctrlGrpAmpsEntry 19 } + +ctrlGrpAmpsHVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Volts Group H" + ::= { ctrlGrpAmpsEntry 20 } + +ctrlGrpAmpsI OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DeciAmps Group I" + ::= { ctrlGrpAmpsEntry 21 } + +ctrlGrpAmpsJ OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DeciAmps Group J" + ::= { ctrlGrpAmpsEntry 22 } + +ctrlGrpAmpsK OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DeciAmps Group K" + ::= { ctrlGrpAmpsEntry 23 } + +ctrlGrpAmpsL OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DeciAmps Group L" + ::= { ctrlGrpAmpsEntry 24 } + +ctrlGrpAmpsM OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DeciAmps Group M" + ::= { ctrlGrpAmpsEntry 25 } + +ctrlGrpAmpsN OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DeciAmps Group N" + ::= { ctrlGrpAmpsEntry 26 } + +ctrlGrpAmpsO OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DeciAmps Group O" + ::= { ctrlGrpAmpsEntry 27 } + +ctrlGrpAmpsP OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "DeciAmps Group P" + ::= { ctrlGrpAmpsEntry 28 } + +ctrlGrpAmpsIVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Volts Group I" + ::= { ctrlGrpAmpsEntry 29 } + +ctrlGrpAmpsJVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Volts Group J" + ::= { ctrlGrpAmpsEntry 30 } + +ctrlGrpAmpsKVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Volts Group K" + ::= { ctrlGrpAmpsEntry 31 } + +ctrlGrpAmpsLVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Volts Group L" + ::= { ctrlGrpAmpsEntry 32 } + +ctrlGrpAmpsMVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Volts Group M" + ::= { ctrlGrpAmpsEntry 33 } + +ctrlGrpAmpsNVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Volts Group N" + ::= { ctrlGrpAmpsEntry 34 } + +ctrlGrpAmpsOVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Volts Group O" + ::= { ctrlGrpAmpsEntry 35 } + +ctrlGrpAmpsPVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Volts Group P" + ::= { ctrlGrpAmpsEntry 36 } + +ctrlOutletEntry OBJECT-TYPE + SYNTAX CtrlOutletEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the control outlet table: each entry contains +an index (ctrlOutletIndex) and other sensor details" + INDEX { ctrlOutletIndex } + ::= { ctrlOutletTable 1 } + +CtrlOutletEntry ::= SEQUENCE { + ctrlOutletIndex INTEGER, + ctrlOutletName DisplayString, + ctrlOutletStatus Gauge32, + ctrlOutletFeedback Gauge32, + ctrlOutletPending Gauge32, + ctrlOutletDeciAmps Gauge32, + ctrlOutletGroup DisplayString, + ctrlOutletUpDelay Gauge32, + ctrlOutletDwnDelay Gauge32, + ctrlOutletRbtDuration Gauge32, + ctrlOutletURL DisplayString, + ctrlOutletPOAAction Gauge32, + ctrlOutletPOADelay Gauge32, + ctrlOutletkWattHrs Gauge32, + ctrlOutletPower Gauge32, + ctrlOutletRbtDelay Gauge32, + ctrlOutletStatusTime Gauge32 +} + +ctrlOutletIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Outlet Number" + ::= { ctrlOutletEntry 1 } + +ctrlOutletName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Outlet Friendly Name" + ::= { ctrlOutletEntry 2 } + +ctrlOutletStatus OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Current Outlet Status: 0 = Off, 1 = On | Outlet Action Write: 0 = Cancel Pending, 1 = On, 2 = On Delayed, 3 = Off Immediate, 4 = Off Delayed, 5 = Reboot, 6 = Reboot Delayed, 7 = Clear kWh (POA units only)" + ::= { ctrlOutletEntry 3 } + +ctrlOutletFeedback OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Outlet Feedback Value, should be equal to status" + ::= { ctrlOutletEntry 4 } + +ctrlOutletPending OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Outlet Status Read to change to: 0 = Off, 1 = On | Outlet Action Write: 0 = Cancel Pending, 1 = On, 2 = On Delayed, 3 = Off Immediate, 4 = Off Delayed, 5 = Reboot, 6 = Reboot Delayed, 7 = Clear kWh (POA units only)" + ::= { ctrlOutletEntry 5 } + +ctrlOutletDeciAmps OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Outlet DeciAmps reading" + ::= { ctrlOutletEntry 6 } + +ctrlOutletGroup OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Outlet Group (A to G)" + ::= { ctrlOutletEntry 7 } + +ctrlOutletUpDelay OBJECT-TYPE + SYNTAX Gauge32 + UNITS "seconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Outlet Power Up Delay" + ::= { ctrlOutletEntry 8 } + +ctrlOutletDwnDelay OBJECT-TYPE + SYNTAX Gauge32 + UNITS "seconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Outlet Power Down Delay" + ::= { ctrlOutletEntry 9 } + +ctrlOutletRbtDuration OBJECT-TYPE + SYNTAX Gauge32 + UNITS "seconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Outlet Reboot Duration" + ::= { ctrlOutletEntry 10 } + +ctrlOutletURL OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Outlet URL" + ::= { ctrlOutletEntry 11 } + +ctrlOutletPOAAction OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION "POA Action: 1 = Off, 2 = On, 3 = Last, 0 = POA not supported on this unit type" + ::= { ctrlOutletEntry 12 } + +ctrlOutletPOADelay OBJECT-TYPE + SYNTAX Gauge32 + UNITS "seconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "POA Delay" + ::= { ctrlOutletEntry 13 } + +ctrlOutletkWattHrs OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Reading for kWatt-Hours" + ::= { ctrlOutletEntry 14 } + +ctrlOutletPower OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power" + ::= { ctrlOutletEntry 15 } + +ctrlOutletRbtDelay OBJECT-TYPE + SYNTAX Gauge32 + UNITS "seconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Outlet Reboot Delay" + ::= { ctrlOutletEntry 16 } + +ctrlOutletStatusTime OBJECT-TYPE + SYNTAX Gauge32 + UNITS "seconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Seconds Since Outlet Last Changed Its Status" + ::= { ctrlOutletEntry 17 } + +dewPointSensorEntry OBJECT-TYPE + SYNTAX DewPointSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the dew point sensor table: each entry contains +an index (dewPointSensorIndex) and other sensor details" + INDEX { dewPointSensorIndex } + ::= { dewPointSensorTable 1 } + +DewPointSensorEntry ::= SEQUENCE { + dewPointSensorIndex INTEGER, + dewPointSensorSerial DisplayString, + dewPointSensorName DisplayString, + dewPointSensorAvail Gauge32, + dewPointSensorTempC INTEGER, + dewPointSensorTempF INTEGER, + dewPointSensorHumidity INTEGER, + dewPointSensorDewPointC INTEGER, + dewPointSensorDewPointF INTEGER +} + +dewPointSensorIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { dewPointSensorEntry 1 } + +dewPointSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { dewPointSensorEntry 2 } + +dewPointSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { dewPointSensorEntry 3 } + +dewPointSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { dewPointSensorEntry 4 } + +dewPointSensorTempC OBJECT-TYPE + SYNTAX INTEGER(-50..100) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Temperature reading in C" + ::= { dewPointSensorEntry 5 } + +dewPointSensorTempF OBJECT-TYPE + SYNTAX INTEGER(-58..212) + UNITS "Degrees Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Temperature reading in F" + ::= { dewPointSensorEntry 6 } + +dewPointSensorHumidity OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Humidity reading" + ::= { dewPointSensorEntry 7 } + +dewPointSensorDewPointC OBJECT-TYPE + SYNTAX INTEGER(-50..100) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Dew point reading in C" + ::= { dewPointSensorEntry 8 } + +dewPointSensorDewPointF OBJECT-TYPE + SYNTAX INTEGER(-58..212) + UNITS "Degrees Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Dew point reading in F" + ::= { dewPointSensorEntry 9 } + +digitalSensorEntry OBJECT-TYPE + SYNTAX DigitalSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the digital sensor table: each entry contains +an index (digitalSensorIndex) and other sensor details" + INDEX { digitalSensorIndex } + ::= { digitalSensorTable 1 } + +DigitalSensorEntry ::= SEQUENCE { + digitalSensorIndex INTEGER, + digitalSensorSerial DisplayString, + digitalSensorName DisplayString, + digitalSensorAvail Gauge32, + digitalSensorDigital INTEGER +} + +digitalSensorIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { digitalSensorEntry 1 } + +digitalSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { digitalSensorEntry 2 } + +digitalSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { digitalSensorEntry 3 } + +digitalSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { digitalSensorEntry 4 } + +digitalSensorDigital OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Digital sensor status" + ::= { digitalSensorEntry 5 } + +dstsEntry OBJECT-TYPE + SYNTAX DstsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the DSTS table: each entry contains +an index (dstsIndex) and other details" + INDEX { dstsIndex } + ::= { dstsTable 1 } + +DstsEntry ::= SEQUENCE { + dstsIndex INTEGER, + dstsSerial DisplayString, + dstsName DisplayString, + dstsAvail Gauge32, + dstsVoltsA Gauge32, + dstsDeciAmpsA Gauge32, + dstsVoltsB Gauge32, + dstsDeciAmpsB Gauge32, + dstsSourceAActive Gauge32, + dstsSourceBActive Gauge32, + dstsPowerStatusA Gauge32, + dstsPowerStatusB Gauge32, + dstsSourceATempC INTEGER, + dstsSourceBTempC INTEGER +} + +dstsIndex OBJECT-TYPE + SYNTAX INTEGER(1..1) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { dstsEntry 1 } + +dstsSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { dstsEntry 2 } + +dstsName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { dstsEntry 3 } + +dstsAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { dstsEntry 4 } + +dstsVoltsA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RMS Voltage of Side A" + ::= { dstsEntry 5 } + +dstsDeciAmpsA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RMS Current of Side A in deciamps" + ::= { dstsEntry 6 } + +dstsVoltsB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RMS Voltage of Side B" + ::= { dstsEntry 7 } + +dstsDeciAmpsB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RMS Current of Side B in deciamps" + ::= { dstsEntry 8 } + +dstsSourceAActive OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "If 99, source A active" + ::= { dstsEntry 9 } + +dstsSourceBActive OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "If 99, source B active" + ::= { dstsEntry 10 } + +dstsPowerStatusA OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Power Quality of source A" + ::= { dstsEntry 11 } + +dstsPowerStatusB OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Power Quality of Source B" + ::= { dstsEntry 12 } + +dstsSourceATempC OBJECT-TYPE + SYNTAX INTEGER(-20..50) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Source A temp in C" + ::= { dstsEntry 13 } + +dstsSourceBTempC OBJECT-TYPE + SYNTAX INTEGER(-20..50) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Source B temp in C" + ::= { dstsEntry 14 } + +cpmSensorEntry OBJECT-TYPE + SYNTAX CpmSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the city power sensor table: each entry contains +an index (cpmSensorIndex) and other sensor details" + INDEX { cpmSensorIndex } + ::= { cpmSensorTable 1 } + +CpmSensorEntry ::= SEQUENCE { + cpmSensorIndex INTEGER, + cpmSensorSerial DisplayString, + cpmSensorName DisplayString, + cpmSensorAvail Gauge32, + cpmSensorStatus INTEGER +} + +cpmSensorIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { cpmSensorEntry 1 } + +cpmSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { cpmSensorEntry 2 } + +cpmSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { cpmSensorEntry 3 } + +cpmSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { cpmSensorEntry 4 } + +cpmSensorStatus OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "City Power sensor status" + ::= { cpmSensorEntry 5 } + +smokeAlarmEntry OBJECT-TYPE + SYNTAX SmokeAlarmEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the smoke alarm sensor table: each entry contains +an index (smokeAlarmIndex) and other sensor details" + INDEX { smokeAlarmIndex } + ::= { smokeAlarmTable 1 } + +SmokeAlarmEntry ::= SEQUENCE { + smokeAlarmIndex INTEGER, + smokeAlarmSerial DisplayString, + smokeAlarmName DisplayString, + smokeAlarmAvail Gauge32, + smokeAlarmStatus INTEGER +} + +smokeAlarmIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { smokeAlarmEntry 1 } + +smokeAlarmSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { smokeAlarmEntry 2 } + +smokeAlarmName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { smokeAlarmEntry 3 } + +smokeAlarmAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { smokeAlarmEntry 4 } + +smokeAlarmStatus OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Smoke alarm status" + ::= { smokeAlarmEntry 5 } + +neg48VdcSensorEntry OBJECT-TYPE + SYNTAX Neg48VdcSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the -48Vdc sensor table: each entry contains +an index (neg48VdcSensorIndex) and other sensor details" + INDEX { neg48VdcSensorIndex } + ::= { neg48VdcSensorTable 1 } + +Neg48VdcSensorEntry ::= SEQUENCE { + neg48VdcSensorIndex INTEGER, + neg48VdcSensorSerial DisplayString, + neg48VdcSensorName DisplayString, + neg48VdcSensorAvail Gauge32, + neg48VdcSensorVoltage INTEGER +} + +neg48VdcSensorIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { neg48VdcSensorEntry 1 } + +neg48VdcSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { neg48VdcSensorEntry 2 } + +neg48VdcSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { neg48VdcSensorEntry 3 } + +neg48VdcSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { neg48VdcSensorEntry 4 } + +neg48VdcSensorVoltage OBJECT-TYPE + SYNTAX INTEGER(-100..10) + UNITS "Volts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "-48Vdc Sensor value" + ::= { neg48VdcSensorEntry 5 } + +pos30VdcSensorEntry OBJECT-TYPE + SYNTAX Pos30VdcSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the 30Vdc sensor table: each entry contains +an index (pos30VdcSensorIndex) and other sensor details" + INDEX { pos30VdcSensorIndex } + ::= { pos30VdcSensorTable 1 } + +Pos30VdcSensorEntry ::= SEQUENCE { + pos30VdcSensorIndex INTEGER, + pos30VdcSensorSerial DisplayString, + pos30VdcSensorName DisplayString, + pos30VdcSensorAvail Gauge32, + pos30VdcSensorVoltage INTEGER +} + +pos30VdcSensorIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { pos30VdcSensorEntry 1 } + +pos30VdcSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { pos30VdcSensorEntry 2 } + +pos30VdcSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { pos30VdcSensorEntry 3 } + +pos30VdcSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { pos30VdcSensorEntry 4 } + +pos30VdcSensorVoltage OBJECT-TYPE + SYNTAX INTEGER(-10..100) + UNITS "Volts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "30Vdc Sensor value" + ::= { pos30VdcSensorEntry 5 } + +analogSensorEntry OBJECT-TYPE + SYNTAX AnalogSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the analog input table: each entry contains +an index (analogSensorIndex) and other sensor details" + INDEX { analogSensorIndex } + ::= { analogSensorTable 1 } + +AnalogSensorEntry ::= SEQUENCE { + analogSensorIndex INTEGER, + analogSensorSerial DisplayString, + analogSensorName DisplayString, + analogSensorAvail Gauge32, + analogSensorAnalog INTEGER +} + +analogSensorIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { analogSensorEntry 1 } + +analogSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { analogSensorEntry 2 } + +analogSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { analogSensorEntry 3 } + +analogSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { analogSensorEntry 4 } + +analogSensorAnalog OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Analog Sensor Value" + ::= { analogSensorEntry 5 } + +ctrl3ChIECEntry OBJECT-TYPE + SYNTAX Ctrl3ChIECEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the 3 phase outlet control table: each entry contains +an index (ctrl3ChIECIndex) and other outlet control monitoring details" + INDEX { ctrl3ChIECIndex } + ::= { ctrl3ChIECTable 1 } + +Ctrl3ChIECEntry ::= SEQUENCE { + ctrl3ChIECIndex INTEGER, + ctrl3ChIECSerial DisplayString, + ctrl3ChIECName DisplayString, + ctrl3ChIECAvail Gauge32, + ctrl3ChIECkWattHrsA Gauge32, + ctrl3ChIECVoltsA Gauge32, + ctrl3ChIECVoltPeakA Gauge32, + ctrl3ChIECDeciAmpsA Gauge32, + ctrl3ChIECDeciAmpsPeakA Gauge32, + ctrl3ChIECRealPowerA Gauge32, + ctrl3ChIECApparentPowerA Gauge32, + ctrl3ChIECPowerFactorA INTEGER, + ctrl3ChIECkWattHrsB Gauge32, + ctrl3ChIECVoltsB Gauge32, + ctrl3ChIECVoltPeakB Gauge32, + ctrl3ChIECDeciAmpsB Gauge32, + ctrl3ChIECDeciAmpsPeakB Gauge32, + ctrl3ChIECRealPowerB Gauge32, + ctrl3ChIECApparentPowerB Gauge32, + ctrl3ChIECPowerFactorB INTEGER, + ctrl3ChIECkWattHrsC Gauge32, + ctrl3ChIECVoltsC Gauge32, + ctrl3ChIECVoltPeakC Gauge32, + ctrl3ChIECDeciAmpsC Gauge32, + ctrl3ChIECDeciAmpsPeakC Gauge32, + ctrl3ChIECRealPowerC Gauge32, + ctrl3ChIECApparentPowerC Gauge32, + ctrl3ChIECPowerFactorC INTEGER, + ctrl3ChIECkWattHrsTotal Gauge32, + ctrl3ChIECRealPowerTotal Gauge32 +} + +ctrl3ChIECIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { ctrl3ChIECEntry 1 } + +ctrl3ChIECSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { ctrl3ChIECEntry 2 } + +ctrl3ChIECName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { ctrl3ChIECEntry 3 } + +ctrl3ChIECAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { ctrl3ChIECEntry 4 } + +ctrl3ChIECkWattHrsA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Reading for kWatt-Hours (Phase A)" + ::= { ctrl3ChIECEntry 5 } + +ctrl3ChIECVoltsA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Phase A)" + ::= { ctrl3ChIECEntry 6 } + +ctrl3ChIECVoltPeakA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Volts (Phase A)" + ::= { ctrl3ChIECEntry 7 } + +ctrl3ChIECDeciAmpsA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for DeciAmps (Phase A)" + ::= { ctrl3ChIECEntry 8 } + +ctrl3ChIECDeciAmpsPeakA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-DeciAmps (Phase A)" + ::= { ctrl3ChIECEntry 9 } + +ctrl3ChIECRealPowerA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Phase A)" + ::= { ctrl3ChIECEntry 10 } + +ctrl3ChIECApparentPowerA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Apparent Power (Phase A)" + ::= { ctrl3ChIECEntry 11 } + +ctrl3ChIECPowerFactorA OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Phase A)" + ::= { ctrl3ChIECEntry 12 } + +ctrl3ChIECkWattHrsB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Reading for kWatt-Hours (Phase B)" + ::= { ctrl3ChIECEntry 13 } + +ctrl3ChIECVoltsB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Phase B)" + ::= { ctrl3ChIECEntry 14 } + +ctrl3ChIECVoltPeakB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Volts (Phase B)" + ::= { ctrl3ChIECEntry 15 } + +ctrl3ChIECDeciAmpsB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for DeciAmps (Phase B)" + ::= { ctrl3ChIECEntry 16 } + +ctrl3ChIECDeciAmpsPeakB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-DeciAmps (Phase B)" + ::= { ctrl3ChIECEntry 17 } + +ctrl3ChIECRealPowerB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Phase B)" + ::= { ctrl3ChIECEntry 18 } + +ctrl3ChIECApparentPowerB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Apparent Power (Phase B)" + ::= { ctrl3ChIECEntry 19 } + +ctrl3ChIECPowerFactorB OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Phase B)" + ::= { ctrl3ChIECEntry 20 } + +ctrl3ChIECkWattHrsC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Reading for kWatt-Hours (Phase C)" + ::= { ctrl3ChIECEntry 21 } + +ctrl3ChIECVoltsC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Phase C)" + ::= { ctrl3ChIECEntry 22 } + +ctrl3ChIECVoltPeakC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Volts (Phase C)" + ::= { ctrl3ChIECEntry 23 } + +ctrl3ChIECDeciAmpsC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for DeciAmps (Phase C)" + ::= { ctrl3ChIECEntry 24 } + +ctrl3ChIECDeciAmpsPeakC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-DeciAmps (Phase C)" + ::= { ctrl3ChIECEntry 25 } + +ctrl3ChIECRealPowerC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Phase C)" + ::= { ctrl3ChIECEntry 26 } + +ctrl3ChIECApparentPowerC OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Apparent Power (Phase C)" + ::= { ctrl3ChIECEntry 27 } + +ctrl3ChIECPowerFactorC OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Phase C)" + ::= { ctrl3ChIECEntry 28 } + +ctrl3ChIECkWattHrsTotal OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Reading for kWatt-Hours (Total)" + ::= { ctrl3ChIECEntry 29 } + +ctrl3ChIECRealPowerTotal OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Watts (Total)" + ::= { ctrl3ChIECEntry 30 } + +climateRelayEntry OBJECT-TYPE + SYNTAX ClimateRelayEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the climate relay table: each entry contains +an index (climateRelayIndex) and other power strip details" + INDEX { climateRelayIndex } + ::= { climateRelayTable 1 } + +ClimateRelayEntry ::= SEQUENCE { + climateRelayIndex INTEGER, + climateRelaySerial DisplayString, + climateRelayName DisplayString, + climateRelayAvail Gauge32, + climateRelayTempC INTEGER, + climateRelayTempF INTEGER, + climateRelayIO1 INTEGER, + climateRelayIO2 INTEGER, + climateRelayIO3 INTEGER, + climateRelayIO4 INTEGER, + climateRelayIO5 INTEGER, + climateRelayIO6 INTEGER +} + +climateRelayIndex OBJECT-TYPE + SYNTAX INTEGER(1..1) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { climateRelayEntry 1 } + +climateRelaySerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { climateRelayEntry 2 } + +climateRelayName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { climateRelayEntry 3 } + +climateRelayAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { climateRelayEntry 4 } + +climateRelayTempC OBJECT-TYPE + SYNTAX INTEGER(-50..100) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Temperature (C)" + ::= { climateRelayEntry 5 } + +climateRelayTempF OBJECT-TYPE + SYNTAX INTEGER(-58..212) + UNITS "Degress Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Temperature (F)" + ::= { climateRelayEntry 6 } + +climateRelayIO1 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 1" + ::= { climateRelayEntry 7 } + +climateRelayIO2 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 2" + ::= { climateRelayEntry 8 } + +climateRelayIO3 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 3" + ::= { climateRelayEntry 9 } + +climateRelayIO4 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 4" + ::= { climateRelayEntry 10 } + +climateRelayIO5 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 5" + ::= { climateRelayEntry 11 } + +climateRelayIO6 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 6" + ::= { climateRelayEntry 12 } + +ctrlRelayEntry OBJECT-TYPE + SYNTAX CtrlRelayEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the control relay table: each entry contains +an index (ctrlRelayIndex) and other sensor details" + INDEX { ctrlRelayIndex } + ::= { ctrlRelayTable 1 } + +CtrlRelayEntry ::= SEQUENCE { + ctrlRelayIndex INTEGER, + ctrlRelayName DisplayString, + ctrlRelayState Gauge32, + ctrlRelayLatchingMode Gauge32, + ctrlRelayOverride Gauge32, + ctrlRelayAcknowledge Gauge32 +} + +ctrlRelayIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Relay Number" + ::= { ctrlRelayEntry 1 } + +ctrlRelayName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Relay Friendly Name" + ::= { ctrlRelayEntry 2 } + +ctrlRelayState OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Relay Status: 0 = Off, 1 = On" + ::= { ctrlRelayEntry 3 } + +ctrlRelayLatchingMode OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Relay latching mode: 0 = Non-latching, 1 = Latching" + ::= { ctrlRelayEntry 4 } + +ctrlRelayOverride OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Relay Override Mode: 0 - None, 1 - On, 2 - Off" + ::= { ctrlRelayEntry 5 } + +ctrlRelayAcknowledge OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Acknowledge write a 1, always reads back 0" + ::= { ctrlRelayEntry 6 } + +airSpeedSwitchSensorEntry OBJECT-TYPE + SYNTAX AirSpeedSwitchSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the air speed switch sensor table: each entry contains +an index (airSpeedSwitchIndex) and other sensor details" + INDEX { airSpeedSwitchSensorIndex } + ::= { airSpeedSwitchSensorTable 1 } + +AirSpeedSwitchSensorEntry ::= SEQUENCE { + airSpeedSwitchSensorIndex INTEGER, + airSpeedSwitchSensorSerial DisplayString, + airSpeedSwitchSensorName DisplayString, + airSpeedSwitchSensorAvail Gauge32, + airSpeedSwitchSensorAirSpeed INTEGER +} + +airSpeedSwitchSensorIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { airSpeedSwitchSensorEntry 1 } + +airSpeedSwitchSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { airSpeedSwitchSensorEntry 2 } + +airSpeedSwitchSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { airSpeedSwitchSensorEntry 3 } + +airSpeedSwitchSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { airSpeedSwitchSensorEntry 4 } + +airSpeedSwitchSensorAirSpeed OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Air Speed Switch Status" + ::= { airSpeedSwitchSensorEntry 5 } + +powerDMEntry OBJECT-TYPE + SYNTAX PowerDMEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the DM48 current monitor table: each entry contains +an index (powerDMIndex) and other sensor details" + INDEX { powerDMIndex } + ::= { powerDMTable 1 } + +PowerDMEntry ::= SEQUENCE { + powerDMIndex INTEGER, + powerDMSerial DisplayString, + powerDMName DisplayString, + powerDMAvail Gauge32, + powerDMUnitInfoTitle DisplayString, + powerDMUnitInfoVersion DisplayString, + powerDMUnitInfoMainCount INTEGER, + powerDMUnitInfoAuxCount INTEGER, + powerDMChannelName1 DisplayString, + powerDMChannelName2 DisplayString, + powerDMChannelName3 DisplayString, + powerDMChannelName4 DisplayString, + powerDMChannelName5 DisplayString, + powerDMChannelName6 DisplayString, + powerDMChannelName7 DisplayString, + powerDMChannelName8 DisplayString, + powerDMChannelName9 DisplayString, + powerDMChannelName10 DisplayString, + powerDMChannelName11 DisplayString, + powerDMChannelName12 DisplayString, + powerDMChannelName13 DisplayString, + powerDMChannelName14 DisplayString, + powerDMChannelName15 DisplayString, + powerDMChannelName16 DisplayString, + powerDMChannelName17 DisplayString, + powerDMChannelName18 DisplayString, + powerDMChannelName19 DisplayString, + powerDMChannelName20 DisplayString, + powerDMChannelName21 DisplayString, + powerDMChannelName22 DisplayString, + powerDMChannelName23 DisplayString, + powerDMChannelName24 DisplayString, + powerDMChannelName25 DisplayString, + powerDMChannelName26 DisplayString, + powerDMChannelName27 DisplayString, + powerDMChannelName28 DisplayString, + powerDMChannelName29 DisplayString, + powerDMChannelName30 DisplayString, + powerDMChannelName31 DisplayString, + powerDMChannelName32 DisplayString, + powerDMChannelName33 DisplayString, + powerDMChannelName34 DisplayString, + powerDMChannelName35 DisplayString, + powerDMChannelName36 DisplayString, + powerDMChannelName37 DisplayString, + powerDMChannelName38 DisplayString, + powerDMChannelName39 DisplayString, + powerDMChannelName40 DisplayString, + powerDMChannelName41 DisplayString, + powerDMChannelName42 DisplayString, + powerDMChannelName43 DisplayString, + powerDMChannelName44 DisplayString, + powerDMChannelName45 DisplayString, + powerDMChannelName46 DisplayString, + powerDMChannelName47 DisplayString, + powerDMChannelName48 DisplayString, + powerDMChannelFriendly1 DisplayString, + powerDMChannelFriendly2 DisplayString, + powerDMChannelFriendly3 DisplayString, + powerDMChannelFriendly4 DisplayString, + powerDMChannelFriendly5 DisplayString, + powerDMChannelFriendly6 DisplayString, + powerDMChannelFriendly7 DisplayString, + powerDMChannelFriendly8 DisplayString, + powerDMChannelFriendly9 DisplayString, + powerDMChannelFriendly10 DisplayString, + powerDMChannelFriendly11 DisplayString, + powerDMChannelFriendly12 DisplayString, + powerDMChannelFriendly13 DisplayString, + powerDMChannelFriendly14 DisplayString, + powerDMChannelFriendly15 DisplayString, + powerDMChannelFriendly16 DisplayString, + powerDMChannelFriendly17 DisplayString, + powerDMChannelFriendly18 DisplayString, + powerDMChannelFriendly19 DisplayString, + powerDMChannelFriendly20 DisplayString, + powerDMChannelFriendly21 DisplayString, + powerDMChannelFriendly22 DisplayString, + powerDMChannelFriendly23 DisplayString, + powerDMChannelFriendly24 DisplayString, + powerDMChannelFriendly25 DisplayString, + powerDMChannelFriendly26 DisplayString, + powerDMChannelFriendly27 DisplayString, + powerDMChannelFriendly28 DisplayString, + powerDMChannelFriendly29 DisplayString, + powerDMChannelFriendly30 DisplayString, + powerDMChannelFriendly31 DisplayString, + powerDMChannelFriendly32 DisplayString, + powerDMChannelFriendly33 DisplayString, + powerDMChannelFriendly34 DisplayString, + powerDMChannelFriendly35 DisplayString, + powerDMChannelFriendly36 DisplayString, + powerDMChannelFriendly37 DisplayString, + powerDMChannelFriendly38 DisplayString, + powerDMChannelFriendly39 DisplayString, + powerDMChannelFriendly40 DisplayString, + powerDMChannelFriendly41 DisplayString, + powerDMChannelFriendly42 DisplayString, + powerDMChannelFriendly43 DisplayString, + powerDMChannelFriendly44 DisplayString, + powerDMChannelFriendly45 DisplayString, + powerDMChannelFriendly46 DisplayString, + powerDMChannelFriendly47 DisplayString, + powerDMChannelFriendly48 DisplayString, + powerDMChannelGroup1 DisplayString, + powerDMChannelGroup2 DisplayString, + powerDMChannelGroup3 DisplayString, + powerDMChannelGroup4 DisplayString, + powerDMChannelGroup5 DisplayString, + powerDMChannelGroup6 DisplayString, + powerDMChannelGroup7 DisplayString, + powerDMChannelGroup8 DisplayString, + powerDMChannelGroup9 DisplayString, + powerDMChannelGroup10 DisplayString, + powerDMChannelGroup11 DisplayString, + powerDMChannelGroup12 DisplayString, + powerDMChannelGroup13 DisplayString, + powerDMChannelGroup14 DisplayString, + powerDMChannelGroup15 DisplayString, + powerDMChannelGroup16 DisplayString, + powerDMChannelGroup17 DisplayString, + powerDMChannelGroup18 DisplayString, + powerDMChannelGroup19 DisplayString, + powerDMChannelGroup20 DisplayString, + powerDMChannelGroup21 DisplayString, + powerDMChannelGroup22 DisplayString, + powerDMChannelGroup23 DisplayString, + powerDMChannelGroup24 DisplayString, + powerDMChannelGroup25 DisplayString, + powerDMChannelGroup26 DisplayString, + powerDMChannelGroup27 DisplayString, + powerDMChannelGroup28 DisplayString, + powerDMChannelGroup29 DisplayString, + powerDMChannelGroup30 DisplayString, + powerDMChannelGroup31 DisplayString, + powerDMChannelGroup32 DisplayString, + powerDMChannelGroup33 DisplayString, + powerDMChannelGroup34 DisplayString, + powerDMChannelGroup35 DisplayString, + powerDMChannelGroup36 DisplayString, + powerDMChannelGroup37 DisplayString, + powerDMChannelGroup38 DisplayString, + powerDMChannelGroup39 DisplayString, + powerDMChannelGroup40 DisplayString, + powerDMChannelGroup41 DisplayString, + powerDMChannelGroup42 DisplayString, + powerDMChannelGroup43 DisplayString, + powerDMChannelGroup44 DisplayString, + powerDMChannelGroup45 DisplayString, + powerDMChannelGroup46 DisplayString, + powerDMChannelGroup47 DisplayString, + powerDMChannelGroup48 DisplayString, + powerDMDeciAmps1 INTEGER, + powerDMDeciAmps2 INTEGER, + powerDMDeciAmps3 INTEGER, + powerDMDeciAmps4 INTEGER, + powerDMDeciAmps5 INTEGER, + powerDMDeciAmps6 INTEGER, + powerDMDeciAmps7 INTEGER, + powerDMDeciAmps8 INTEGER, + powerDMDeciAmps9 INTEGER, + powerDMDeciAmps10 INTEGER, + powerDMDeciAmps11 INTEGER, + powerDMDeciAmps12 INTEGER, + powerDMDeciAmps13 INTEGER, + powerDMDeciAmps14 INTEGER, + powerDMDeciAmps15 INTEGER, + powerDMDeciAmps16 INTEGER, + powerDMDeciAmps17 INTEGER, + powerDMDeciAmps18 INTEGER, + powerDMDeciAmps19 INTEGER, + powerDMDeciAmps20 INTEGER, + powerDMDeciAmps21 INTEGER, + powerDMDeciAmps22 INTEGER, + powerDMDeciAmps23 INTEGER, + powerDMDeciAmps24 INTEGER, + powerDMDeciAmps25 INTEGER, + powerDMDeciAmps26 INTEGER, + powerDMDeciAmps27 INTEGER, + powerDMDeciAmps28 INTEGER, + powerDMDeciAmps29 INTEGER, + powerDMDeciAmps30 INTEGER, + powerDMDeciAmps31 INTEGER, + powerDMDeciAmps32 INTEGER, + powerDMDeciAmps33 INTEGER, + powerDMDeciAmps34 INTEGER, + powerDMDeciAmps35 INTEGER, + powerDMDeciAmps36 INTEGER, + powerDMDeciAmps37 INTEGER, + powerDMDeciAmps38 INTEGER, + powerDMDeciAmps39 INTEGER, + powerDMDeciAmps40 INTEGER, + powerDMDeciAmps41 INTEGER, + powerDMDeciAmps42 INTEGER, + powerDMDeciAmps43 INTEGER, + powerDMDeciAmps44 INTEGER, + powerDMDeciAmps45 INTEGER, + powerDMDeciAmps46 INTEGER, + powerDMDeciAmps47 INTEGER, + powerDMDeciAmps48 INTEGER +} + +powerDMIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { powerDMEntry 1 } + +powerDMSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { powerDMEntry 2 } + +powerDMName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { powerDMEntry 3 } + +powerDMAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { powerDMEntry 4 } + +powerDMUnitInfoTitle OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Type of Unit" + ::= { powerDMEntry 5 } + +powerDMUnitInfoVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Unit Version Number" + ::= { powerDMEntry 6 } + +powerDMUnitInfoMainCount OBJECT-TYPE + SYNTAX INTEGER(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of Main (Total Amps) Channels on the Unit" + ::= { powerDMEntry 7 } + +powerDMUnitInfoAuxCount OBJECT-TYPE + SYNTAX INTEGER(0..48) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Number of Auxiliary (Outlet) Channels on the Unit" + ::= { powerDMEntry 8 } + +powerDMChannelName1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 1 Factory Name" + ::= { powerDMEntry 9 } + +powerDMChannelName2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 2 Factory Name" + ::= { powerDMEntry 10 } + +powerDMChannelName3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 3 Factory Name" + ::= { powerDMEntry 11 } + +powerDMChannelName4 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 4 Factory Name" + ::= { powerDMEntry 12 } + +powerDMChannelName5 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 5 Factory Name" + ::= { powerDMEntry 13 } + +powerDMChannelName6 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 6 Factory Name" + ::= { powerDMEntry 14 } + +powerDMChannelName7 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 7 Factory Name" + ::= { powerDMEntry 15 } + +powerDMChannelName8 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 8 Factory Name" + ::= { powerDMEntry 16 } + +powerDMChannelName9 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 9 Factory Name" + ::= { powerDMEntry 17 } + +powerDMChannelName10 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 10 Factory Name" + ::= { powerDMEntry 18 } + +powerDMChannelName11 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 11 Factory Name" + ::= { powerDMEntry 19 } + +powerDMChannelName12 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 12 Factory Name" + ::= { powerDMEntry 20 } + +powerDMChannelName13 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 13 Factory Name" + ::= { powerDMEntry 21 } + +powerDMChannelName14 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 14 Factory Name" + ::= { powerDMEntry 22 } + +powerDMChannelName15 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 15 Factory Name" + ::= { powerDMEntry 23 } + +powerDMChannelName16 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 16 Factory Name" + ::= { powerDMEntry 24 } + +powerDMChannelName17 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 17 Factory Name" + ::= { powerDMEntry 25 } + +powerDMChannelName18 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 18 Factory Name" + ::= { powerDMEntry 26 } + +powerDMChannelName19 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 19 Factory Name" + ::= { powerDMEntry 27 } + +powerDMChannelName20 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 20 Factory Name" + ::= { powerDMEntry 28 } + +powerDMChannelName21 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 21 Factory Name" + ::= { powerDMEntry 29 } + +powerDMChannelName22 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 22 Factory Name" + ::= { powerDMEntry 30 } + +powerDMChannelName23 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 23 Factory Name" + ::= { powerDMEntry 31 } + +powerDMChannelName24 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 24 Factory Name" + ::= { powerDMEntry 32 } + +powerDMChannelName25 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 25 Factory Name" + ::= { powerDMEntry 33 } + +powerDMChannelName26 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 26 Factory Name" + ::= { powerDMEntry 34 } + +powerDMChannelName27 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 27 Factory Name" + ::= { powerDMEntry 35 } + +powerDMChannelName28 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 28 Factory Name" + ::= { powerDMEntry 36 } + +powerDMChannelName29 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 29 Factory Name" + ::= { powerDMEntry 37 } + +powerDMChannelName30 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 30 Factory Name" + ::= { powerDMEntry 38 } + +powerDMChannelName31 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 31 Factory Name" + ::= { powerDMEntry 39 } + +powerDMChannelName32 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 32 Factory Name" + ::= { powerDMEntry 40 } + +powerDMChannelName33 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 33 Factory Name" + ::= { powerDMEntry 41 } + +powerDMChannelName34 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 34 Factory Name" + ::= { powerDMEntry 42 } + +powerDMChannelName35 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 35 Factory Name" + ::= { powerDMEntry 43 } + +powerDMChannelName36 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 36 Factory Name" + ::= { powerDMEntry 44 } + +powerDMChannelName37 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 37 Factory Name" + ::= { powerDMEntry 45 } + +powerDMChannelName38 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 38 Factory Name" + ::= { powerDMEntry 46 } + +powerDMChannelName39 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 39 Factory Name" + ::= { powerDMEntry 47 } + +powerDMChannelName40 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 40 Factory Name" + ::= { powerDMEntry 48 } + +powerDMChannelName41 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 41 Factory Name" + ::= { powerDMEntry 49 } + +powerDMChannelName42 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 42 Factory Name" + ::= { powerDMEntry 50 } + +powerDMChannelName43 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 43 Factory Name" + ::= { powerDMEntry 51 } + +powerDMChannelName44 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 44 Factory Name" + ::= { powerDMEntry 52 } + +powerDMChannelName45 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 45 Factory Name" + ::= { powerDMEntry 53 } + +powerDMChannelName46 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 46 Factory Name" + ::= { powerDMEntry 54 } + +powerDMChannelName47 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 47 Factory Name" + ::= { powerDMEntry 55 } + +powerDMChannelName48 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 48 Factory Name" + ::= { powerDMEntry 56 } + +powerDMChannelFriendly1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 1 Friendly Name" + ::= { powerDMEntry 57 } + +powerDMChannelFriendly2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 2 Friendly Name" + ::= { powerDMEntry 58 } + +powerDMChannelFriendly3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 3 Friendly Name" + ::= { powerDMEntry 59 } + +powerDMChannelFriendly4 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 4 Friendly Name" + ::= { powerDMEntry 60 } + +powerDMChannelFriendly5 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 5 Friendly Name" + ::= { powerDMEntry 61 } + +powerDMChannelFriendly6 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 6 Friendly Name" + ::= { powerDMEntry 62 } + +powerDMChannelFriendly7 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 7 Friendly Name" + ::= { powerDMEntry 63 } + +powerDMChannelFriendly8 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 8 Friendly Name" + ::= { powerDMEntry 64 } + +powerDMChannelFriendly9 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 9 Friendly Name" + ::= { powerDMEntry 65 } + +powerDMChannelFriendly10 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 10 Friendly Name" + ::= { powerDMEntry 66 } + +powerDMChannelFriendly11 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 11 Friendly Name" + ::= { powerDMEntry 67 } + +powerDMChannelFriendly12 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 12 Friendly Name" + ::= { powerDMEntry 68 } + +powerDMChannelFriendly13 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 13 Friendly Name" + ::= { powerDMEntry 69 } + +powerDMChannelFriendly14 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 14 Friendly Name" + ::= { powerDMEntry 70 } + +powerDMChannelFriendly15 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 15 Friendly Name" + ::= { powerDMEntry 71 } + +powerDMChannelFriendly16 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 16 Friendly Name" + ::= { powerDMEntry 72 } + +powerDMChannelFriendly17 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 17 Friendly Name" + ::= { powerDMEntry 73 } + +powerDMChannelFriendly18 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 18 Friendly Name" + ::= { powerDMEntry 74 } + +powerDMChannelFriendly19 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 19 Friendly Name" + ::= { powerDMEntry 75 } + +powerDMChannelFriendly20 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 20 Friendly Name" + ::= { powerDMEntry 76 } + +powerDMChannelFriendly21 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 21 Friendly Name" + ::= { powerDMEntry 77 } + +powerDMChannelFriendly22 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 22 Friendly Name" + ::= { powerDMEntry 78 } + +powerDMChannelFriendly23 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 23 Friendly Name" + ::= { powerDMEntry 79 } + +powerDMChannelFriendly24 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 24 Friendly Name" + ::= { powerDMEntry 80 } + +powerDMChannelFriendly25 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 25 Friendly Name" + ::= { powerDMEntry 81 } + +powerDMChannelFriendly26 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 26 Friendly Name" + ::= { powerDMEntry 82 } + +powerDMChannelFriendly27 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 27 Friendly Name" + ::= { powerDMEntry 83 } + +powerDMChannelFriendly28 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 28 Friendly Name" + ::= { powerDMEntry 84 } + +powerDMChannelFriendly29 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 29 Friendly Name" + ::= { powerDMEntry 85 } + +powerDMChannelFriendly30 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 30 Friendly Name" + ::= { powerDMEntry 86 } + +powerDMChannelFriendly31 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 31 Friendly Name" + ::= { powerDMEntry 87 } + +powerDMChannelFriendly32 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 32 Friendly Name" + ::= { powerDMEntry 88 } + +powerDMChannelFriendly33 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 33 Friendly Name" + ::= { powerDMEntry 89 } + +powerDMChannelFriendly34 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 34 Friendly Name" + ::= { powerDMEntry 90 } + +powerDMChannelFriendly35 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 35 Friendly Name" + ::= { powerDMEntry 91 } + +powerDMChannelFriendly36 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 36 Friendly Name" + ::= { powerDMEntry 92 } + +powerDMChannelFriendly37 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 37 Friendly Name" + ::= { powerDMEntry 93 } + +powerDMChannelFriendly38 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 38 Friendly Name" + ::= { powerDMEntry 94 } + +powerDMChannelFriendly39 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 39 Friendly Name" + ::= { powerDMEntry 95 } + +powerDMChannelFriendly40 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 40 Friendly Name" + ::= { powerDMEntry 96 } + +powerDMChannelFriendly41 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 41 Friendly Name" + ::= { powerDMEntry 97 } + +powerDMChannelFriendly42 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 42 Friendly Name" + ::= { powerDMEntry 98 } + +powerDMChannelFriendly43 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 43 Friendly Name" + ::= { powerDMEntry 99 } + +powerDMChannelFriendly44 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 44 Friendly Name" + ::= { powerDMEntry 100 } + +powerDMChannelFriendly45 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 45 Friendly Name" + ::= { powerDMEntry 101 } + +powerDMChannelFriendly46 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 46 Friendly Name" + ::= { powerDMEntry 102 } + +powerDMChannelFriendly47 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 47 Friendly Name" + ::= { powerDMEntry 103 } + +powerDMChannelFriendly48 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 48 Friendly Name" + ::= { powerDMEntry 104 } + +powerDMChannelGroup1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 1 Group" + ::= { powerDMEntry 105 } + +powerDMChannelGroup2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 2 Group" + ::= { powerDMEntry 106 } + +powerDMChannelGroup3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 3 Group" + ::= { powerDMEntry 107 } + +powerDMChannelGroup4 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 4 Group" + ::= { powerDMEntry 108 } + +powerDMChannelGroup5 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 5 Group" + ::= { powerDMEntry 109 } + +powerDMChannelGroup6 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 6 Group" + ::= { powerDMEntry 110 } + +powerDMChannelGroup7 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 7 Group" + ::= { powerDMEntry 111 } + +powerDMChannelGroup8 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 8 Group" + ::= { powerDMEntry 112 } + +powerDMChannelGroup9 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 9 Group" + ::= { powerDMEntry 113 } + +powerDMChannelGroup10 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 10 Group" + ::= { powerDMEntry 114 } + +powerDMChannelGroup11 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 11 Group" + ::= { powerDMEntry 115 } + +powerDMChannelGroup12 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 12 Group" + ::= { powerDMEntry 116 } + +powerDMChannelGroup13 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 13 Group" + ::= { powerDMEntry 117 } + +powerDMChannelGroup14 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 14 Group" + ::= { powerDMEntry 118 } + +powerDMChannelGroup15 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 15 Group" + ::= { powerDMEntry 119 } + +powerDMChannelGroup16 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 16 Group" + ::= { powerDMEntry 120 } + +powerDMChannelGroup17 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 17 Group" + ::= { powerDMEntry 121 } + +powerDMChannelGroup18 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 18 Group" + ::= { powerDMEntry 122 } + +powerDMChannelGroup19 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 19 Group" + ::= { powerDMEntry 123 } + +powerDMChannelGroup20 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 20 Group" + ::= { powerDMEntry 124 } + +powerDMChannelGroup21 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 21 Group" + ::= { powerDMEntry 125 } + +powerDMChannelGroup22 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 22 Group" + ::= { powerDMEntry 126 } + +powerDMChannelGroup23 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 23 Group" + ::= { powerDMEntry 127 } + +powerDMChannelGroup24 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 24 Group" + ::= { powerDMEntry 128 } + +powerDMChannelGroup25 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 25 Group" + ::= { powerDMEntry 129 } + +powerDMChannelGroup26 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 26 Group" + ::= { powerDMEntry 130 } + +powerDMChannelGroup27 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 27 Group" + ::= { powerDMEntry 131 } + +powerDMChannelGroup28 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 28 Group" + ::= { powerDMEntry 132 } + +powerDMChannelGroup29 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 29 Group" + ::= { powerDMEntry 133 } + +powerDMChannelGroup30 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 30 Group" + ::= { powerDMEntry 134 } + +powerDMChannelGroup31 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 31 Group" + ::= { powerDMEntry 135 } + +powerDMChannelGroup32 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 32 Group" + ::= { powerDMEntry 136 } + +powerDMChannelGroup33 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 33 Group" + ::= { powerDMEntry 137 } + +powerDMChannelGroup34 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 34 Group" + ::= { powerDMEntry 138 } + +powerDMChannelGroup35 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 35 Group" + ::= { powerDMEntry 139 } + +powerDMChannelGroup36 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 36 Group" + ::= { powerDMEntry 140 } + +powerDMChannelGroup37 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 37 Group" + ::= { powerDMEntry 141 } + +powerDMChannelGroup38 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 38 Group" + ::= { powerDMEntry 142 } + +powerDMChannelGroup39 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 39 Group" + ::= { powerDMEntry 143 } + +powerDMChannelGroup40 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 40 Group" + ::= { powerDMEntry 144 } + +powerDMChannelGroup41 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 41 Group" + ::= { powerDMEntry 145 } + +powerDMChannelGroup42 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 42 Group" + ::= { powerDMEntry 146 } + +powerDMChannelGroup43 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 43 Group" + ::= { powerDMEntry 147 } + +powerDMChannelGroup44 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 44 Group" + ::= { powerDMEntry 148 } + +powerDMChannelGroup45 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 45 Group" + ::= { powerDMEntry 149 } + +powerDMChannelGroup46 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 46 Group" + ::= { powerDMEntry 150 } + +powerDMChannelGroup47 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 47 Group" + ::= { powerDMEntry 151 } + +powerDMChannelGroup48 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Channel 48 Group" + ::= { powerDMEntry 152 } + +powerDMDeciAmps1 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 153 } + +powerDMDeciAmps2 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 154 } + +powerDMDeciAmps3 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 155 } + +powerDMDeciAmps4 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 156 } + +powerDMDeciAmps5 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 157 } + +powerDMDeciAmps6 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 158 } + +powerDMDeciAmps7 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 159 } + +powerDMDeciAmps8 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 160 } + +powerDMDeciAmps9 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 161 } + +powerDMDeciAmps10 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 162 } + +powerDMDeciAmps11 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 163 } + +powerDMDeciAmps12 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 164 } + +powerDMDeciAmps13 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 165 } + +powerDMDeciAmps14 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 166 } + +powerDMDeciAmps15 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 167 } + +powerDMDeciAmps16 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 168 } + +powerDMDeciAmps17 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 169 } + +powerDMDeciAmps18 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 170 } + +powerDMDeciAmps19 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 171 } + +powerDMDeciAmps20 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 172 } + +powerDMDeciAmps21 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 173 } + +powerDMDeciAmps22 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 174 } + +powerDMDeciAmps23 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 175 } + +powerDMDeciAmps24 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 176 } + +powerDMDeciAmps25 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 177 } + +powerDMDeciAmps26 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 178 } + +powerDMDeciAmps27 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 179 } + +powerDMDeciAmps28 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 180 } + +powerDMDeciAmps29 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 181 } + +powerDMDeciAmps30 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 182 } + +powerDMDeciAmps31 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 183 } + +powerDMDeciAmps32 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 184 } + +powerDMDeciAmps33 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 185 } + +powerDMDeciAmps34 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 186 } + +powerDMDeciAmps35 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 187 } + +powerDMDeciAmps36 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 188 } + +powerDMDeciAmps37 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 189 } + +powerDMDeciAmps38 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 190 } + +powerDMDeciAmps39 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 191 } + +powerDMDeciAmps40 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 192 } + +powerDMDeciAmps41 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 193 } + +powerDMDeciAmps42 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 194 } + +powerDMDeciAmps43 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 195 } + +powerDMDeciAmps44 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 196 } + +powerDMDeciAmps45 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 197 } + +powerDMDeciAmps46 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 198 } + +powerDMDeciAmps47 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 199 } + +powerDMDeciAmps48 OBJECT-TYPE + SYNTAX INTEGER(0..1209) + UNITS "0.1 Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current in deciamps" + ::= { powerDMEntry 200 } + +ioExpanderEntry OBJECT-TYPE + SYNTAX IoExpanderEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the IO Expander table: each entry contains +an index (ioExpanderIndex) and other details" + INDEX { ioExpanderIndex } + ::= { ioExpanderTable 1 } + +IoExpanderEntry ::= SEQUENCE { + ioExpanderIndex INTEGER, + ioExpanderSerial DisplayString, + ioExpanderName DisplayString, + ioExpanderAvail Gauge32, + ioExpanderFriendlyName1 DisplayString, + ioExpanderFriendlyName2 DisplayString, + ioExpanderFriendlyName3 DisplayString, + ioExpanderFriendlyName4 DisplayString, + ioExpanderFriendlyName5 DisplayString, + ioExpanderFriendlyName6 DisplayString, + ioExpanderFriendlyName7 DisplayString, + ioExpanderFriendlyName8 DisplayString, + ioExpanderFriendlyName9 DisplayString, + ioExpanderFriendlyName10 DisplayString, + ioExpanderFriendlyName11 DisplayString, + ioExpanderFriendlyName12 DisplayString, + ioExpanderFriendlyName13 DisplayString, + ioExpanderFriendlyName14 DisplayString, + ioExpanderFriendlyName15 DisplayString, + ioExpanderFriendlyName16 DisplayString, + ioExpanderFriendlyName17 DisplayString, + ioExpanderFriendlyName18 DisplayString, + ioExpanderFriendlyName19 DisplayString, + ioExpanderFriendlyName20 DisplayString, + ioExpanderFriendlyName21 DisplayString, + ioExpanderFriendlyName22 DisplayString, + ioExpanderFriendlyName23 DisplayString, + ioExpanderFriendlyName24 DisplayString, + ioExpanderFriendlyName25 DisplayString, + ioExpanderFriendlyName26 DisplayString, + ioExpanderFriendlyName27 DisplayString, + ioExpanderFriendlyName28 DisplayString, + ioExpanderFriendlyName29 DisplayString, + ioExpanderFriendlyName30 DisplayString, + ioExpanderFriendlyName31 DisplayString, + ioExpanderFriendlyName32 DisplayString, + ioExpanderIO1 INTEGER, + ioExpanderIO2 INTEGER, + ioExpanderIO3 INTEGER, + ioExpanderIO4 INTEGER, + ioExpanderIO5 INTEGER, + ioExpanderIO6 INTEGER, + ioExpanderIO7 INTEGER, + ioExpanderIO8 INTEGER, + ioExpanderIO9 INTEGER, + ioExpanderIO10 INTEGER, + ioExpanderIO11 INTEGER, + ioExpanderIO12 INTEGER, + ioExpanderIO13 INTEGER, + ioExpanderIO14 INTEGER, + ioExpanderIO15 INTEGER, + ioExpanderIO16 INTEGER, + ioExpanderIO17 INTEGER, + ioExpanderIO18 INTEGER, + ioExpanderIO19 INTEGER, + ioExpanderIO20 INTEGER, + ioExpanderIO21 INTEGER, + ioExpanderIO22 INTEGER, + ioExpanderIO23 INTEGER, + ioExpanderIO24 INTEGER, + ioExpanderIO25 INTEGER, + ioExpanderIO26 INTEGER, + ioExpanderIO27 INTEGER, + ioExpanderIO28 INTEGER, + ioExpanderIO29 INTEGER, + ioExpanderIO30 INTEGER, + ioExpanderIO31 INTEGER, + ioExpanderIO32 INTEGER, + ioExpanderRelayName1 DisplayString, + ioExpanderRelayState1 Gauge32, + ioExpanderRelayLatchingMode1 Gauge32, + ioExpanderRelayOverride1 Gauge32, + ioExpanderRelayAcknowledge1 Gauge32, + ioExpanderRelayName2 DisplayString, + ioExpanderRelayState2 Gauge32, + ioExpanderRelayLatchingMode2 Gauge32, + ioExpanderRelayOverride2 Gauge32, + ioExpanderRelayAcknowledge2 Gauge32, + ioExpanderRelayName3 DisplayString, + ioExpanderRelayState3 Gauge32, + ioExpanderRelayLatchingMode3 Gauge32, + ioExpanderRelayOverride3 Gauge32, + ioExpanderRelayAcknowledge3 Gauge32 +} + +ioExpanderIndex OBJECT-TYPE + SYNTAX INTEGER(1..1) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { ioExpanderEntry 1 } + +ioExpanderSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { ioExpanderEntry 2 } + +ioExpanderName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { ioExpanderEntry 3 } + +ioExpanderAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { ioExpanderEntry 4 } + +ioExpanderFriendlyName1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 1 Friendly Name" + ::= { ioExpanderEntry 5 } + +ioExpanderFriendlyName2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 2 Friendly Name" + ::= { ioExpanderEntry 6 } + +ioExpanderFriendlyName3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 3 Friendly Name" + ::= { ioExpanderEntry 7 } + +ioExpanderFriendlyName4 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 4 Friendly Name" + ::= { ioExpanderEntry 8 } + +ioExpanderFriendlyName5 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 5 Friendly Name" + ::= { ioExpanderEntry 9 } + +ioExpanderFriendlyName6 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 6 Friendly Name" + ::= { ioExpanderEntry 10 } + +ioExpanderFriendlyName7 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 7 Friendly Name" + ::= { ioExpanderEntry 11 } + +ioExpanderFriendlyName8 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 8 Friendly Name" + ::= { ioExpanderEntry 12 } + +ioExpanderFriendlyName9 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 9 Friendly Name" + ::= { ioExpanderEntry 13 } + +ioExpanderFriendlyName10 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 10 Friendly Name" + ::= { ioExpanderEntry 14 } + +ioExpanderFriendlyName11 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 11 Friendly Name" + ::= { ioExpanderEntry 15 } + +ioExpanderFriendlyName12 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 12 Friendly Name" + ::= { ioExpanderEntry 16 } + +ioExpanderFriendlyName13 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 13 Friendly Name" + ::= { ioExpanderEntry 17 } + +ioExpanderFriendlyName14 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 14 Friendly Name" + ::= { ioExpanderEntry 18 } + +ioExpanderFriendlyName15 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 15 Friendly Name" + ::= { ioExpanderEntry 19 } + +ioExpanderFriendlyName16 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 16 Friendly Name" + ::= { ioExpanderEntry 20 } + +ioExpanderFriendlyName17 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 17 Friendly Name" + ::= { ioExpanderEntry 21 } + +ioExpanderFriendlyName18 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 18 Friendly Name" + ::= { ioExpanderEntry 22 } + +ioExpanderFriendlyName19 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 19 Friendly Name" + ::= { ioExpanderEntry 23 } + +ioExpanderFriendlyName20 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 20 Friendly Name" + ::= { ioExpanderEntry 24 } + +ioExpanderFriendlyName21 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 21 Friendly Name" + ::= { ioExpanderEntry 25 } + +ioExpanderFriendlyName22 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 22 Friendly Name" + ::= { ioExpanderEntry 26 } + +ioExpanderFriendlyName23 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 23 Friendly Name" + ::= { ioExpanderEntry 27 } + +ioExpanderFriendlyName24 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 24 Friendly Name" + ::= { ioExpanderEntry 28 } + +ioExpanderFriendlyName25 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 25 Friendly Name" + ::= { ioExpanderEntry 29 } + +ioExpanderFriendlyName26 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 26 Friendly Name" + ::= { ioExpanderEntry 30 } + +ioExpanderFriendlyName27 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 27 Friendly Name" + ::= { ioExpanderEntry 31 } + +ioExpanderFriendlyName28 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 28 Friendly Name" + ::= { ioExpanderEntry 32 } + +ioExpanderFriendlyName29 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 29 Friendly Name" + ::= { ioExpanderEntry 33 } + +ioExpanderFriendlyName30 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 30 Friendly Name" + ::= { ioExpanderEntry 34 } + +ioExpanderFriendlyName31 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 31 Friendly Name" + ::= { ioExpanderEntry 35 } + +ioExpanderFriendlyName32 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "IO 32 Friendly Name" + ::= { ioExpanderEntry 36 } + +ioExpanderIO1 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 1" + ::= { ioExpanderEntry 37 } + +ioExpanderIO2 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 2" + ::= { ioExpanderEntry 38 } + +ioExpanderIO3 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 3" + ::= { ioExpanderEntry 39 } + +ioExpanderIO4 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 4" + ::= { ioExpanderEntry 40 } + +ioExpanderIO5 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 5" + ::= { ioExpanderEntry 41 } + +ioExpanderIO6 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 6" + ::= { ioExpanderEntry 42 } + +ioExpanderIO7 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 7" + ::= { ioExpanderEntry 43 } + +ioExpanderIO8 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 8" + ::= { ioExpanderEntry 44 } + +ioExpanderIO9 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 9" + ::= { ioExpanderEntry 45 } + +ioExpanderIO10 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 10" + ::= { ioExpanderEntry 46 } + +ioExpanderIO11 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 11" + ::= { ioExpanderEntry 47 } + +ioExpanderIO12 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 12" + ::= { ioExpanderEntry 48 } + +ioExpanderIO13 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 13" + ::= { ioExpanderEntry 49 } + +ioExpanderIO14 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 14" + ::= { ioExpanderEntry 50 } + +ioExpanderIO15 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 15" + ::= { ioExpanderEntry 51 } + +ioExpanderIO16 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 16" + ::= { ioExpanderEntry 52 } + +ioExpanderIO17 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 17" + ::= { ioExpanderEntry 53 } + +ioExpanderIO18 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 18" + ::= { ioExpanderEntry 54 } + +ioExpanderIO19 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 19" + ::= { ioExpanderEntry 55 } + +ioExpanderIO20 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 20" + ::= { ioExpanderEntry 56 } + +ioExpanderIO21 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 21" + ::= { ioExpanderEntry 57 } + +ioExpanderIO22 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 22" + ::= { ioExpanderEntry 58 } + +ioExpanderIO23 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 23" + ::= { ioExpanderEntry 59 } + +ioExpanderIO24 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 24" + ::= { ioExpanderEntry 60 } + +ioExpanderIO25 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 25" + ::= { ioExpanderEntry 61 } + +ioExpanderIO26 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 26" + ::= { ioExpanderEntry 62 } + +ioExpanderIO27 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 27" + ::= { ioExpanderEntry 63 } + +ioExpanderIO28 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 28" + ::= { ioExpanderEntry 64 } + +ioExpanderIO29 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 29" + ::= { ioExpanderEntry 65 } + +ioExpanderIO30 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 30" + ::= { ioExpanderEntry 66 } + +ioExpanderIO31 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 31" + ::= { ioExpanderEntry 67 } + +ioExpanderIO32 OBJECT-TYPE + SYNTAX INTEGER(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Analog Input 32" + ::= { ioExpanderEntry 68 } + +ioExpanderRelayName1 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Relay1 Friendly Name" + ::= { ioExpanderEntry 69 } + +ioExpanderRelayState1 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Relay1 Current Status: 0 = Off, 1 = On" + ::= { ioExpanderEntry 70 } + +ioExpanderRelayLatchingMode1 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Relay1 Latching mode: 0 = Non-latching, 1 = Latching" + ::= { ioExpanderEntry 71 } + +ioExpanderRelayOverride1 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Relay1 Override Mode: 0 - None, 1 - On, 2 - Off" + ::= { ioExpanderEntry 72 } + +ioExpanderRelayAcknowledge1 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Relay1 Acknowledge write a 1, always reads back 0" + ::= { ioExpanderEntry 73 } + +ioExpanderRelayName2 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Relay2 Friendly Name" + ::= { ioExpanderEntry 74 } + +ioExpanderRelayState2 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Relay2 Current Status: 0 = Off, 1 = On" + ::= { ioExpanderEntry 75 } + +ioExpanderRelayLatchingMode2 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Relay2 Latching mode: 0 = Non-latching, 1 = Latching" + ::= { ioExpanderEntry 76 } + +ioExpanderRelayOverride2 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Relay2 Override Mode: 0 - None, 1 - On, 2 - Off" + ::= { ioExpanderEntry 77 } + +ioExpanderRelayAcknowledge2 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Relay2 Acknowledge write a 1, always reads back 0" + ::= { ioExpanderEntry 78 } + +ioExpanderRelayName3 OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Relay3 Friendly Name" + ::= { ioExpanderEntry 79 } + +ioExpanderRelayState3 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Relay3 Current Status: 0 = Off, 1 = On" + ::= { ioExpanderEntry 80 } + +ioExpanderRelayLatchingMode3 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Relay3 Latching mode: 0 = Non-latching, 1 = Latching" + ::= { ioExpanderEntry 81 } + +ioExpanderRelayOverride3 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Relay3 Override Mode: 0 - None, 1 - On, 2 - Off" + ::= { ioExpanderEntry 82 } + +ioExpanderRelayAcknowledge3 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Relay3 Acknowledge write a 1, always reads back 0" + ::= { ioExpanderEntry 83 } + +t3hdSensorEntry OBJECT-TYPE + SYNTAX T3hdSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the T3HD sensor table: each entry contains +an index (t3hdIndex) and other sensor details" + INDEX { t3hdSensorIndex } + ::= { t3hdSensorTable 1 } + +T3hdSensorEntry ::= SEQUENCE { + t3hdSensorIndex INTEGER, + t3hdSensorSerial DisplayString, + t3hdSensorName DisplayString, + t3hdSensorAvail Gauge32, + t3hdSensorIntName DisplayString, + t3hdSensorIntTempC INTEGER, + t3hdSensorIntTempF INTEGER, + t3hdSensorIntHumidity INTEGER, + t3hdSensorIntDewPointC INTEGER, + t3hdSensorIntDewPointF INTEGER, + t3hdSensorExt1Avail Gauge32, + t3hdSensorExt1Name DisplayString, + t3hdSensorExt1TempC INTEGER, + t3hdSensorExt1TempF INTEGER, + t3hdSensorExt2Avail Gauge32, + t3hdSensorExt2Name DisplayString, + t3hdSensorExt2TempC INTEGER, + t3hdSensorExt2TempF INTEGER +} + +t3hdSensorIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { t3hdSensorEntry 1 } + +t3hdSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { t3hdSensorEntry 2 } + +t3hdSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { t3hdSensorEntry 3 } + +t3hdSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { t3hdSensorEntry 4 } + +t3hdSensorIntName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Internal Friendly Name" + ::= { t3hdSensorEntry 5 } + +t3hdSensorIntTempC OBJECT-TYPE + SYNTAX INTEGER(-50..100) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Internal Temperature reading in C" + ::= { t3hdSensorEntry 6 } + +t3hdSensorIntTempF OBJECT-TYPE + SYNTAX INTEGER(-58..212) + UNITS "Degrees Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Internal Temperature reading in F" + ::= { t3hdSensorEntry 7 } + +t3hdSensorIntHumidity OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Internal Humidity reading" + ::= { t3hdSensorEntry 8 } + +t3hdSensorIntDewPointC OBJECT-TYPE + SYNTAX INTEGER(-50..100) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Internal Dew Point reading in C" + ::= { t3hdSensorEntry 9 } + +t3hdSensorIntDewPointF OBJECT-TYPE + SYNTAX INTEGER(-58..212) + UNITS "Degress Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Internal Dew Point reading in F" + ::= { t3hdSensorEntry 10 } + +t3hdSensorExt1Avail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "External 1 status: 0 = unplugged, 1 = normal operation, 2 = device error" + ::= { t3hdSensorEntry 11 } + +t3hdSensorExt1Name OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "External 1 Friendly Name" + ::= { t3hdSensorEntry 12 } + +t3hdSensorExt1TempC OBJECT-TYPE + SYNTAX INTEGER(-50..100) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "External 1 Temperature reading in C" + ::= { t3hdSensorEntry 13 } + +t3hdSensorExt1TempF OBJECT-TYPE + SYNTAX INTEGER(-58..212) + UNITS "Degress Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "External 1 Temperature reading in F" + ::= { t3hdSensorEntry 14 } + +t3hdSensorExt2Avail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "External 2 status: 0 = unplugged, 1 = normal operation, 2 = device error" + ::= { t3hdSensorEntry 15 } + +t3hdSensorExt2Name OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "External 2 Friendly Name" + ::= { t3hdSensorEntry 16 } + +t3hdSensorExt2TempC OBJECT-TYPE + SYNTAX INTEGER(-50..100) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "External 2 Temperature reading in C" + ::= { t3hdSensorEntry 17 } + +t3hdSensorExt2TempF OBJECT-TYPE + SYNTAX INTEGER(-58..212) + UNITS "Degress Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "External 2 Temperature reading in F" + ::= { t3hdSensorEntry 18 } + +thdSensorEntry OBJECT-TYPE + SYNTAX ThdSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the THD sensor table: each entry contains +an index (thdIndex) and other sensor details" + INDEX { thdSensorIndex } + ::= { thdSensorTable 1 } + +ThdSensorEntry ::= SEQUENCE { + thdSensorIndex INTEGER, + thdSensorSerial DisplayString, + thdSensorName DisplayString, + thdSensorAvail Gauge32, + thdSensorTempC INTEGER, + thdSensorTempF INTEGER, + thdSensorHumidity INTEGER, + thdSensorDewPointC INTEGER, + thdSensorDewPointF INTEGER +} + +thdSensorIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { thdSensorEntry 1 } + +thdSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { thdSensorEntry 2 } + +thdSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { thdSensorEntry 3 } + +thdSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { thdSensorEntry 4 } + +thdSensorTempC OBJECT-TYPE + SYNTAX INTEGER(-50..100) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Temperature reading in C" + ::= { thdSensorEntry 5 } + +thdSensorTempF OBJECT-TYPE + SYNTAX INTEGER(-58..212) + UNITS "Degrees Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Temperature reading in F" + ::= { thdSensorEntry 6 } + +thdSensorHumidity OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Humidity reading" + ::= { thdSensorEntry 7 } + +thdSensorDewPointC OBJECT-TYPE + SYNTAX INTEGER(-50..100) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Dew Point reading in C" + ::= { thdSensorEntry 8 } + +thdSensorDewPointF OBJECT-TYPE + SYNTAX INTEGER(-58..212) + UNITS "Degress Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Dew Point reading in F" + ::= { thdSensorEntry 9 } + +pos60VdcSensorEntry OBJECT-TYPE + SYNTAX Pos60VdcSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the 60Vdc sensor table: each entry contains +an index (pos60VdcSensorIndex) and other sensor details" + INDEX { pos60VdcSensorIndex } + ::= { pos60VdcSensorTable 1 } + +Pos60VdcSensorEntry ::= SEQUENCE { + pos60VdcSensorIndex INTEGER, + pos60VdcSensorSerial DisplayString, + pos60VdcSensorName DisplayString, + pos60VdcSensorAvail Gauge32, + pos60VdcSensorVoltage INTEGER +} + +pos60VdcSensorIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { pos60VdcSensorEntry 1 } + +pos60VdcSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { pos60VdcSensorEntry 2 } + +pos60VdcSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { pos60VdcSensorEntry 3 } + +pos60VdcSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { pos60VdcSensorEntry 4 } + +pos60VdcSensorVoltage OBJECT-TYPE + SYNTAX INTEGER(-10..100) + UNITS "Volts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "60Vdc Sensor value" + ::= { pos60VdcSensorEntry 5 } + +ctrl2CirTotEntry OBJECT-TYPE + SYNTAX Ctrl2CirTotEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the 3 phase outlet control table: each entry contains +an index (ctrl2CirTotIndex) and other outlet control monitoring details" + INDEX { ctrl2CirTotIndex } + ::= { ctrl2CirTotTable 1 } + +Ctrl2CirTotEntry ::= SEQUENCE { + ctrl2CirTotIndex INTEGER, + ctrl2CirTotSerial DisplayString, + ctrl2CirTotName DisplayString, + ctrl2CirTotAvail Gauge32, + ctrl2CirTotkWattHrsTot Gauge32, + ctrl2CirTotVoltsTot Gauge32, + ctrl2CirTotVoltPeakTot Gauge32, + ctrl2CirTotDeciAmpsTot Gauge32, + ctrl2CirTotDeciAmpsPeakTot Gauge32, + ctrl2CirTotRealPowerTot Gauge32, + ctrl2CirTotApparentPowerTot Gauge32, + ctrl2CirTotPowerFactorTot INTEGER, + ctrl2CirTotkWattHrsA Gauge32, + ctrl2CirTotVoltsA Gauge32, + ctrl2CirTotVoltPeakA Gauge32, + ctrl2CirTotDeciAmpsA Gauge32, + ctrl2CirTotDeciAmpsPeakA Gauge32, + ctrl2CirTotRealPowerA Gauge32, + ctrl2CirTotApparentPowerA Gauge32, + ctrl2CirTotPowerFactorA INTEGER, + ctrl2CirTotkWattHrsB Gauge32, + ctrl2CirTotVoltsB Gauge32, + ctrl2CirTotVoltPeakB Gauge32, + ctrl2CirTotDeciAmpsB Gauge32, + ctrl2CirTotDeciAmpsPeakB Gauge32, + ctrl2CirTotRealPowerB Gauge32, + ctrl2CirTotApparentPowerB Gauge32, + ctrl2CirTotPowerFactorB INTEGER +} + +ctrl2CirTotIndex OBJECT-TYPE + SYNTAX INTEGER(1..100) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { ctrl2CirTotEntry 1 } + +ctrl2CirTotSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { ctrl2CirTotEntry 2 } + +ctrl2CirTotName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { ctrl2CirTotEntry 3 } + +ctrl2CirTotAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { ctrl2CirTotEntry 4 } + +ctrl2CirTotkWattHrsTot OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Reading for kWatt-Hours (Total)" + ::= { ctrl2CirTotEntry 5 } + +ctrl2CirTotVoltsTot OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Total)" + ::= { ctrl2CirTotEntry 6 } + +ctrl2CirTotVoltPeakTot OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Volts (Total)" + ::= { ctrl2CirTotEntry 7 } + +ctrl2CirTotDeciAmpsTot OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for DeciAmps (Total)" + ::= { ctrl2CirTotEntry 8 } + +ctrl2CirTotDeciAmpsPeakTot OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-DeciAmps (Total)" + ::= { ctrl2CirTotEntry 9 } + +ctrl2CirTotRealPowerTot OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Total)" + ::= { ctrl2CirTotEntry 10 } + +ctrl2CirTotApparentPowerTot OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Apparent Power (Total)" + ::= { ctrl2CirTotEntry 11 } + +ctrl2CirTotPowerFactorTot OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Total)" + ::= { ctrl2CirTotEntry 12 } + +ctrl2CirTotkWattHrsA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Reading for kWatt-Hours (Phase A)" + ::= { ctrl2CirTotEntry 13 } + +ctrl2CirTotVoltsA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Phase A)" + ::= { ctrl2CirTotEntry 14 } + +ctrl2CirTotVoltPeakA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Volts (Phase A)" + ::= { ctrl2CirTotEntry 15 } + +ctrl2CirTotDeciAmpsA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for DeciAmps (Phase A)" + ::= { ctrl2CirTotEntry 16 } + +ctrl2CirTotDeciAmpsPeakA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-DeciAmps (Phase A)" + ::= { ctrl2CirTotEntry 17 } + +ctrl2CirTotRealPowerA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Phase A)" + ::= { ctrl2CirTotEntry 18 } + +ctrl2CirTotApparentPowerA OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Apparent Power (Phase A)" + ::= { ctrl2CirTotEntry 19 } + +ctrl2CirTotPowerFactorA OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Phase A)" + ::= { ctrl2CirTotEntry 20 } + +ctrl2CirTotkWattHrsB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current Reading for kWatt-Hours (Phase B)" + ::= { ctrl2CirTotEntry 21 } + +ctrl2CirTotVoltsB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Volts (Phase B)" + ::= { ctrl2CirTotEntry 22 } + +ctrl2CirTotVoltPeakB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-Volts (Phase B)" + ::= { ctrl2CirTotEntry 23 } + +ctrl2CirTotDeciAmpsB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for DeciAmps (Phase B)" + ::= { ctrl2CirTotEntry 24 } + +ctrl2CirTotDeciAmpsPeakB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Peak-DeciAmps (Phase B)" + ::= { ctrl2CirTotEntry 25 } + +ctrl2CirTotRealPowerB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Real Power (Phase B)" + ::= { ctrl2CirTotEntry 26 } + +ctrl2CirTotApparentPowerB OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Apparent Power (Phase B)" + ::= { ctrl2CirTotEntry 27 } + +ctrl2CirTotPowerFactorB OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Power Factor (Phase B)" + ::= { ctrl2CirTotEntry 28 } + +sc10Entry OBJECT-TYPE + SYNTAX Sc10Entry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the sc10 table: each entry contains +an index (sc10Index) and other details" + INDEX { sc10Index } + ::= { sc10Table 1 } + +Sc10Entry ::= SEQUENCE { + sc10Index INTEGER, + sc10Serial DisplayString, + sc10Name DisplayString, + sc10Avail Gauge32, + sc10ControlMode INTEGER, + sc10SetpointC INTEGER, + sc10SetpointF INTEGER, + sc10TempC INTEGER, + sc10TempF INTEGER, + sc10Capacity INTEGER +} + +sc10Index OBJECT-TYPE + SYNTAX INTEGER(1..1) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Table entry index value" + ::= { sc10Entry 1 } + +sc10Serial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { sc10Entry 2 } + +sc10Name OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { sc10Entry 3 } + +sc10Avail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Is device currently plugged in?" + ::= { sc10Entry 4 } + +sc10ControlMode OBJECT-TYPE + SYNTAX INTEGER { setpoint(0), capacity(1) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Control Mode setting indicator" + ::= { sc10Entry 5 } + +sc10SetpointC OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current temperature set point in C" + ::= { sc10Entry 6 } + +sc10SetpointF OBJECT-TYPE + SYNTAX INTEGER(32..212) + UNITS "Degrees Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current temperature set point in F" + ::= { sc10Entry 7 } + +sc10TempC OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "Degrees Celsius" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current internal temperature reading in C" + ::= { sc10Entry 8 } + +sc10TempF OBJECT-TYPE + SYNTAX INTEGER(32..212) + UNITS "Degrees Fahrenheit" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current internal temperature reading in F" + ::= { sc10Entry 9 } + +sc10Capacity OBJECT-TYPE + SYNTAX INTEGER(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current capacity for Fan Speed" + ::= { sc10Entry 10 } + + + +alarmSystem OBJECT IDENTIFIER + ::= { geistV3 101 } + + +alarmCfgTable OBJECT-TYPE + SYNTAX SEQUENCE OF AlarmCfgEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Provides access for alarm configuration. Each row represents an alarm." + ::= { alarmSystem 1 } + + +alarmCfgEntry OBJECT-TYPE + SYNTAX AlarmCfgEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Entry in the alarm cfg table: each entry contains + an index (alarmCfgIndex) and other details" + INDEX { alarmCfgIndex } + ::= { alarmCfgTable 1 } + +AlarmCfgEntry ::= SEQUENCE { + alarmCfgIndex INTEGER, + alarmCfgReadingID OBJECT IDENTIFIER, + alarmCfgThreshold Integer32, + alarmCfgTripSelect INTEGER +} + + +alarmCfgIndex OBJECT-TYPE + SYNTAX INTEGER(1..200) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Table entry index value. Provides unique ID for + alarm, numbered from 1 to 200" + ::= { alarmCfgEntry 1 } + +alarmCfgReadingID OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "OID of a particular measurement to monitor. This object + is also used to create or delete a row. To create a new + row, set the Sensor ID on a row that doesn't exist. Set + the ReadingID to 0.0 to destroy a row." + ::= { alarmCfgEntry 2 } + +alarmCfgThreshold OBJECT-TYPE + SYNTAX Integer32 + UNITS "Tenths" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Depending on TripSelect this value acts as an upper or + lower boundary for the sensor value. The value is in + units of tenths. + SNMP Threshold = Actual Value * 10 + Example: 45 Threshold = 4.5 Amps" + ::= { alarmCfgEntry 3 } + +alarmCfgTripSelect OBJECT-TYPE + SYNTAX INTEGER { tripBelow(0), tripAbove(1) } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Tells if alarm trips above or below the threshold value" + ::= { alarmCfgEntry 4 } + + +gstTrap OBJECT IDENTIFIER ::= { geistV3 32767 } +gstTrapPrefix OBJECT IDENTIFIER ::= { gstTrap 0 } + +gstTestNOTIFY NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Test SNMP Trap" + ::= { gstTrapPrefix 10101 } + +gstClimateTempCNOTIFY NOTIFICATION-TYPE +OBJECTS { climateTempC, climateName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Temperature Sensor Trap" +::= { gstTrapPrefix 10205 } + +gstClimateTempFNOTIFY NOTIFICATION-TYPE +OBJECTS { climateTempF, climateName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Temperature Sensor Trap" +::= { gstTrapPrefix 10206 } + +gstClimateHumidityNOTIFY NOTIFICATION-TYPE +OBJECTS { climateHumidity, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Humidity Sensor Trap" +::= { gstTrapPrefix 10207 } + +gstClimateLightNOTIFY NOTIFICATION-TYPE +OBJECTS { climateLight, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Light Sensor Trap" +::= { gstTrapPrefix 10208 } + +gstClimateAirflowNOTIFY NOTIFICATION-TYPE +OBJECTS { climateAirflow, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Air Flow Sensor Trap" +::= { gstTrapPrefix 10209 } + +gstClimateSoundNOTIFY NOTIFICATION-TYPE +OBJECTS { climateSound, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Sound Sensor Trap" +::= { gstTrapPrefix 10210 } + +gstClimateIO1NOTIFY NOTIFICATION-TYPE +OBJECTS { climateIO1, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate IO1 Sensor Trap" +::= { gstTrapPrefix 10211 } + +gstClimateIO2NOTIFY NOTIFICATION-TYPE +OBJECTS { climateIO2, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate IO2 Sensor Trap" +::= { gstTrapPrefix 10212 } + +gstClimateIO3NOTIFY NOTIFICATION-TYPE +OBJECTS { climateIO3, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate IO3 Sensor Trap" +::= { gstTrapPrefix 10213 } + +gstClimateVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { climateVolts, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Volts Trap" +::= { gstTrapPrefix 10214 } + +gstClimateVoltPeakNOTIFY NOTIFICATION-TYPE +OBJECTS { climateVoltPeak, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Volts Peak Trap" +::= { gstTrapPrefix 10215 } + +gstClimateDeciAmpsANOTIFY NOTIFICATION-TYPE +OBJECTS { climateDeciAmpsA, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Amps A Trap" +::= { gstTrapPrefix 10216 } + +gstClimateDeciAmpPeakANOTIFY NOTIFICATION-TYPE +OBJECTS { climateDeciAmpPeakA, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Amp Peak A Trap" +::= { gstTrapPrefix 10217 } + +gstClimateRealPowerANOTIFY NOTIFICATION-TYPE +OBJECTS { climateRealPowerA, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Real Power A Trap" +::= { gstTrapPrefix 10218 } + +gstClimateApparentPowerANOTIFY NOTIFICATION-TYPE +OBJECTS { climateApparentPowerA, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Apparent Power A Trap" +::= { gstTrapPrefix 10219 } + +gstClimatePowerFactorANOTIFY NOTIFICATION-TYPE +OBJECTS { climatePowerFactorA, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Power Factor A Trap" +::= { gstTrapPrefix 10220 } + +gstClimateDeciAmpsBNOTIFY NOTIFICATION-TYPE +OBJECTS { climateDeciAmpsB, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Amps B Trap" +::= { gstTrapPrefix 10221 } + +gstClimateDeciAmpPeakBNOTIFY NOTIFICATION-TYPE +OBJECTS { climateDeciAmpPeakB, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Amp Peak B Trap" +::= { gstTrapPrefix 10222 } + +gstClimateRealPowerBNOTIFY NOTIFICATION-TYPE +OBJECTS { climateRealPowerB, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Real Power B Trap" +::= { gstTrapPrefix 10223 } + +gstClimateApparentPowerBNOTIFY NOTIFICATION-TYPE +OBJECTS { climateApparentPowerB, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Apparent Power B Trap" +::= { gstTrapPrefix 10224 } + +gstClimatePowerFactorBNOTIFY NOTIFICATION-TYPE +OBJECTS { climatePowerFactorB, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Power Factor B Trap" +::= { gstTrapPrefix 10225 } + +gstClimateDeciAmpsCNOTIFY NOTIFICATION-TYPE +OBJECTS { climateDeciAmpsC, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Amps C Trap" +::= { gstTrapPrefix 10226 } + +gstClimateDeciAmpPeakCNOTIFY NOTIFICATION-TYPE +OBJECTS { climateDeciAmpPeakC, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Amp Peak C Trap" +::= { gstTrapPrefix 10227 } + +gstClimateRealPowerCNOTIFY NOTIFICATION-TYPE +OBJECTS { climateRealPowerC, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Real Power C Trap" +::= { gstTrapPrefix 10228 } + +gstClimateApparentPowerCNOTIFY NOTIFICATION-TYPE +OBJECTS { climateApparentPowerC, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Apparent Power C Trap" +::= { gstTrapPrefix 10229 } + +gstClimatePowerFactorCNOTIFY NOTIFICATION-TYPE +OBJECTS { climatePowerFactorC, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Power Factor C Trap" +::= { gstTrapPrefix 10230 } + +gstClimateDewPointCNOTIFY NOTIFICATION-TYPE +OBJECTS { climateDewPointC, climateName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Dew Point Sensor Trap" +::= { gstTrapPrefix 10231 } + +gstClimateDewPointFNOTIFY NOTIFICATION-TYPE +OBJECTS { climateDewPointF, climateName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Dew Point Sensor Trap" +::= { gstTrapPrefix 10232 } + +gstPowMonkWattHrsNOTIFY NOTIFICATION-TYPE +OBJECTS { powMonkWattHrs, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours Trap" +::= { gstTrapPrefix 10305 } + +gstPowMonVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { powMonVolts, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Trap" +::= { gstTrapPrefix 10306 } + +gstPowMonVoltMaxNOTIFY NOTIFICATION-TYPE +OBJECTS { powMonVoltMax, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Max Trap" +::= { gstTrapPrefix 10307 } + +gstPowMonVoltMinNOTIFY NOTIFICATION-TYPE +OBJECTS { powMonVoltMin, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Min Trap" +::= { gstTrapPrefix 10308 } + +gstPowMonVoltPeakNOTIFY NOTIFICATION-TYPE +OBJECTS { powMonVoltPeak, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volt Peak Trap" +::= { gstTrapPrefix 10309 } + +gstPowMonDeciAmpsNOTIFY NOTIFICATION-TYPE +OBJECTS { powMonDeciAmps, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DeciAmps Trap" +::= { gstTrapPrefix 10310 } + +gstPowMonRealPowerNOTIFY NOTIFICATION-TYPE +OBJECTS { powMonRealPower, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power Trap" +::= { gstTrapPrefix 10311 } + +gstPowMonApparentPowerNOTIFY NOTIFICATION-TYPE +OBJECTS { powMonApparentPower, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power Trap" +::= { gstTrapPrefix 10312 } + +gstPowMonPowerFactorNOTIFY NOTIFICATION-TYPE +OBJECTS { powMonPowerFactor, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor Trap" +::= { gstTrapPrefix 10313 } + +gstPowMonOutlet1NOTIFY NOTIFICATION-TYPE +OBJECTS { powMonOutlet1, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Outlet 1 Clear Trap" +::= { gstTrapPrefix 10314 } + +gstPowMonOutlet2NOTIFY NOTIFICATION-TYPE +OBJECTS { powMonOutlet2, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Outlet 2 Clear Trap" +::= { gstTrapPrefix 10315 } + +gstPowMonOutlet1StatusTimeNOTIFY NOTIFICATION-TYPE +OBJECTS { powMonOutlet1StatusTime, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Outlet1StatusTime Trip Trap" +::= { gstTrapPrefix 10316 } + +gstPowMonOutlet2StatusTimeNOTIFY NOTIFICATION-TYPE +OBJECTS { powMonOutlet2StatusTime, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Outlet2StatusTime Trip Trap" +::= { gstTrapPrefix 10317 } + +gstTempSensorTempCNOTIFY NOTIFICATION-TYPE +OBJECTS { tempSensorTempC, tempSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Temp Sensor - Temperature Trap" +::= { gstTrapPrefix 10405 } + +gstTempSensorTempFNOTIFY NOTIFICATION-TYPE +OBJECTS { tempSensorTempF, tempSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Temp Sensor - Temperature Trap" +::= { gstTrapPrefix 10406 } + +gstAirFlowSensorTempCNOTIFY NOTIFICATION-TYPE +OBJECTS { airFlowSensorTempC, airFlowSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Air Flow Sensor - Temperature Trap" +::= { gstTrapPrefix 10505 } + +gstAirFlowSensorTempFNOTIFY NOTIFICATION-TYPE +OBJECTS { airFlowSensorTempF, airFlowSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Air Flow Sensor - Temperature Trap" +::= { gstTrapPrefix 10506 } + +gstAirFlowSensorFlowNOTIFY NOTIFICATION-TYPE +OBJECTS { airFlowSensorFlow, airFlowSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Air Flow Sensor - Air Flow Trap" +::= { gstTrapPrefix 10507 } + +gstAirFlowSensorHumidityNOTIFY NOTIFICATION-TYPE +OBJECTS { airFlowSensorHumidity, airFlowSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Air Flow Sensor - Humidity" +::= { gstTrapPrefix 10508 } + +gstAirFlowSensorDewPointCNOTIFY NOTIFICATION-TYPE +OBJECTS { airFlowSensorDewPointC, airFlowSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Air Flow Sensor - Dew Point Trap" +::= { gstTrapPrefix 10509 } + +gstAirFlowSensorDewPointFNOTIFY NOTIFICATION-TYPE +OBJECTS { airFlowSensorDewPointF, airFlowSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Air Flow Sensor - Dew Point Trap" +::= { gstTrapPrefix 10510 } + +gstCtrl3ChDELTADeciAmpsANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTADeciAmpsA, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps A Trap" +::= { gstTrapPrefix 10606 } + +gstCtrl3ChDELTADeciAmpsBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTADeciAmpsB, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps B Trap" +::= { gstTrapPrefix 10607 } + +gstCtrl3ChDELTADeciAmpsCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTADeciAmpsC, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps C Trap" +::= { gstTrapPrefix 10608 } + +gstCtrl3ChDELTAkWattHrsTotalNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAkWattHrsTotal, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours Total Trap" +::= { gstTrapPrefix 10609 } + +gstCtrl3ChDELTARealPowerTotalNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTARealPowerTotal, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Watts Total Trap" +::= { gstTrapPrefix 10610 } + +gstCtrl3ChDELTAkWattHrsABNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAkWattHrsAB, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours A Trap" +::= { gstTrapPrefix 10611 } + +gstCtrl3ChDELTAVoltsABNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAVoltsAB, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts AB Trap" +::= { gstTrapPrefix 10612 } + +gstCtrl3ChDELTAVoltPeakABNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAVoltPeakAB, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak AB Trap" +::= { gstTrapPrefix 10613 } + +gstCtrl3ChDELTARealPowerABNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTARealPowerAB, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power AB Trap" +::= { gstTrapPrefix 10614 } + +gstCtrl3ChDELTAApparentPowerABNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAApparentPowerAB, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "VoltAmps AB Trap" +::= { gstTrapPrefix 10615 } + +gstCtrl3ChDELTAPowerFactorABNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAPowerFactorAB, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor AB Trap" +::= { gstTrapPrefix 10616 } + +gstCtrl3ChDELTAkWattHrsBCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAkWattHrsBC, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours BC Trap" +::= { gstTrapPrefix 10617 } + +gstCtrl3ChDELTAVoltsBCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAVoltsBC, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts BC Trap" +::= { gstTrapPrefix 10618 } + +gstCtrl3ChDELTAVoltPeakBCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAVoltPeakBC, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak BC Trap" +::= { gstTrapPrefix 10619 } + +gstCtrl3ChDELTARealPowerBCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTARealPowerBC, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power BC Trap" +::= { gstTrapPrefix 10620 } + +gstCtrl3ChDELTAApparentPowerBCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAApparentPowerBC, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "VoltAmps BC Trap" +::= { gstTrapPrefix 10621 } + +gstCtrl3ChDELTAPowerFactorBCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAPowerFactorBC, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor BC Trap" +::= { gstTrapPrefix 10622 } + +gstCtrl3ChDELTAkWattHrsCANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAkWattHrsCA, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours CA Trap" +::= { gstTrapPrefix 10623 } + +gstCtrl3ChDELTAVoltsCANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAVoltsCA, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts CA Trap" +::= { gstTrapPrefix 10624 } + +gstCtrl3ChDELTAVoltPeakCANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAVoltPeakCA, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak CA Trap" +::= { gstTrapPrefix 10625 } + +gstCtrl3ChDELTARealPowerCANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTARealPowerCA, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power CA Trap" +::= { gstTrapPrefix 10626 } + +gstCtrl3ChDELTAApparentPowerCANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAApparentPowerCA, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "VoltAmps CA Trap" +::= { gstTrapPrefix 10627 } + +gstCtrl3ChDELTAPowerFactorCANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAPowerFactorCA, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor CA Trap" +::= { gstTrapPrefix 10628 } + +gstDoorSensorStatusNOTIFY NOTIFICATION-TYPE +OBJECTS { doorSensorStatus, doorSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Door sensor Trap" +::= { gstTrapPrefix 10705 } + +gstWaterSensorDampnessNOTIFY NOTIFICATION-TYPE +OBJECTS { waterSensorDampness, waterSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Water sensor Trap" +::= { gstTrapPrefix 10805 } + +gstCurrentMonitorDeciAmpsNOTIFY NOTIFICATION-TYPE +OBJECTS { currentMonitorDeciAmps, currentMonitorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Current Monitor Amps Trap" +::= { gstTrapPrefix 10905 } + +gstMillivoltMonitorMVNOTIFY NOTIFICATION-TYPE +OBJECTS { millivoltMonitorMV, millivoltMonitorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Millivolt Monitor Trap" +::= { gstTrapPrefix 11005 } + +gstPow3ChkWattHrsANOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChkWattHrsA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours A Trap" +::= { gstTrapPrefix 11105 } + +gstPow3ChVoltsANOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChVoltsA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts A Trap" +::= { gstTrapPrefix 11106 } + +gstPow3ChVoltMaxANOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChVoltMaxA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Max A Trap" +::= { gstTrapPrefix 11107 } + +gstPow3ChVoltMinANOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChVoltMinA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Min A Trap" +::= { gstTrapPrefix 11108 } + +gstPow3ChVoltPeakANOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChVoltPeakA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volt Peak A Trap" +::= { gstTrapPrefix 11109 } + +gstPow3ChDeciAmpsANOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChDeciAmpsA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps A Trap" +::= { gstTrapPrefix 11110 } + +gstPow3ChRealPowerANOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChRealPowerA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power A Trap" +::= { gstTrapPrefix 11111 } + +gstPow3ChApparentPowerANOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChApparentPowerA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power A Trap" +::= { gstTrapPrefix 11112 } + +gstPow3ChPowerFactorANOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChPowerFactorA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor A Trap" +::= { gstTrapPrefix 11113 } + +gstPow3ChkWattHrsBNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChkWattHrsB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours B Trap" +::= { gstTrapPrefix 11114 } + +gstPow3ChVoltsBNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChVoltsB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts B Trap" +::= { gstTrapPrefix 11115 } + +gstPow3ChVoltMaxBNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChVoltMaxB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Max B Trap" +::= { gstTrapPrefix 11116 } + +gstPow3ChVoltMinBNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChVoltMinB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Min B Trap" +::= { gstTrapPrefix 11117 } + +gstPow3ChVoltPeakBNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChVoltPeakB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volt Peak B Trap" +::= { gstTrapPrefix 11118 } + +gstPow3ChDeciAmpsBNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChDeciAmpsB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps B Trap" +::= { gstTrapPrefix 11119 } + +gstPow3ChRealPowerBNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChRealPowerB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power B Trap" +::= { gstTrapPrefix 11120 } + +gstPow3ChApparentPowerBNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChApparentPowerB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power B Trap" +::= { gstTrapPrefix 11121 } + +gstPow3ChPowerFactorBNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChPowerFactorB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor B Trap" +::= { gstTrapPrefix 11122 } + +gstPow3ChkWattHrsCNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChkWattHrsC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours C Trap" +::= { gstTrapPrefix 11123 } + +gstPow3ChVoltsCNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChVoltsC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts C Trap" +::= { gstTrapPrefix 11124 } + +gstPow3ChVoltMaxCNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChVoltMaxC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Max C Trap" +::= { gstTrapPrefix 11125 } + +gstPow3ChVoltMinCNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChVoltMinC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Min C Trap" +::= { gstTrapPrefix 11126 } + +gstPow3ChVoltPeakCNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChVoltPeakC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volt Peak C Trap" +::= { gstTrapPrefix 11127 } + +gstPow3ChDeciAmpsCNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChDeciAmpsC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps C Trap" +::= { gstTrapPrefix 11128 } + +gstPow3ChRealPowerCNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChRealPowerC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power C Trap" +::= { gstTrapPrefix 11129 } + +gstPow3ChApparentPowerCNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChApparentPowerC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power C Trap" +::= { gstTrapPrefix 11130 } + +gstPow3ChPowerFactorCNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChPowerFactorC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor C Trap" +::= { gstTrapPrefix 11131 } + +gstPow3ChkWattHrsTotalNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChkWattHrsTotal, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours Total Trap" +::= { gstTrapPrefix 11132 } + +gstPow3ChRealPowerTotalNOTIFY NOTIFICATION-TYPE +OBJECTS { pow3ChRealPowerTotal, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power Total Trap" +::= { gstTrapPrefix 11133 } + +gstOutlet1StatusNOTIFY NOTIFICATION-TYPE +OBJECTS { outlet1Status, outletName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Outlet 1 Status Trap" +::= { gstTrapPrefix 11205 } + +gstOutlet2StatusNOTIFY NOTIFICATION-TYPE +OBJECTS { outlet2Status, outletName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Outlet 2 Status Trap" +::= { gstTrapPrefix 11206 } + +gstVsfcSetPointCNOTIFY NOTIFICATION-TYPE +OBJECTS { vsfcSetPointC, vsfcName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc Temp Set Point Sensor Trap" +::= { gstTrapPrefix 11305 } + +gstVsfcSetPointFNOTIFY NOTIFICATION-TYPE +OBJECTS { vsfcSetPointF, vsfcName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc Temp Set Point Sensor Trap" +::= { gstTrapPrefix 11306 } + +gstVsfcFanSpeedNOTIFY NOTIFICATION-TYPE +OBJECTS { vsfcFanSpeed, vsfcName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc Fan Speed Sensor Trap" +::= { gstTrapPrefix 11307 } + +gstVsfcIntTempCNOTIFY NOTIFICATION-TYPE +OBJECTS { vsfcIntTempC, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc Internal Temp Sensor Trap" +::= { gstTrapPrefix 11308 } + +gstVsfcIntTempFNOTIFY NOTIFICATION-TYPE +OBJECTS { vsfcIntTempF, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc Internal Temp Sensor Trap" +::= { gstTrapPrefix 11309 } + +gstVsfcExt1TempCNOTIFY NOTIFICATION-TYPE +OBJECTS { vsfcExt1TempC, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc External Temp 1 Sensor Trap" +::= { gstTrapPrefix 11310 } + +gstVsfcExt1TempFNOTIFY NOTIFICATION-TYPE +OBJECTS { vsfcExt1TempF, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc External Temp 1 Sensor Trap" +::= { gstTrapPrefix 11311 } + +gstVsfcExt2TempCNOTIFY NOTIFICATION-TYPE +OBJECTS { vsfcExt2TempC, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc External Temp 2 Sensor Trap" +::= { gstTrapPrefix 11312 } + +gstVsfcExt2TempFNOTIFY NOTIFICATION-TYPE +OBJECTS { vsfcExt2TempF, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc External Temp 1 Sensor Trap" +::= { gstTrapPrefix 11313 } + +gstVsfcExt3TempCNOTIFY NOTIFICATION-TYPE +OBJECTS { vsfcExt3TempC, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc External Temp 3 Sensor Trap" +::= { gstTrapPrefix 11314 } + +gstVsfcExt3TempFNOTIFY NOTIFICATION-TYPE +OBJECTS { vsfcExt3TempF, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc External Temp 1 Sensor Trap" +::= { gstTrapPrefix 11315 } + +gstVsfcExt4TempCNOTIFY NOTIFICATION-TYPE +OBJECTS { vsfcExt4TempC, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc External Temp 4 Sensor Trap" +::= { gstTrapPrefix 11316 } + +gstVsfcExt4TempFNOTIFY NOTIFICATION-TYPE +OBJECTS { vsfcExt4TempF, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc External Temp 1 Sensor Trap" +::= { gstTrapPrefix 11317 } + +gstCtrl3ChVoltsANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChVoltsA, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts A Trap" +::= { gstTrapPrefix 11405 } + +gstCtrl3ChVoltPeakANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChVoltPeakA, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak A Trap" +::= { gstTrapPrefix 11406 } + +gstCtrl3ChDeciAmpsANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDeciAmpsA, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps A Trap" +::= { gstTrapPrefix 11407 } + +gstCtrl3ChDeciAmpsPeakANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDeciAmpsPeakA, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak A Trap" +::= { gstTrapPrefix 11408 } + +gstCtrl3ChRealPowerANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChRealPowerA, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power A Trap" +::= { gstTrapPrefix 11409 } + +gstCtrl3ChApparentPowerANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChApparentPowerA, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power A Trap" +::= { gstTrapPrefix 11410 } + +gstCtrl3ChPowerFactorANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChPowerFactorA, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor A Trap" +::= { gstTrapPrefix 11411 } + +gstCtrl3ChVoltsBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChVoltsB, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts B Trap" +::= { gstTrapPrefix 11412 } + +gstCtrl3ChVoltPeakBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChVoltPeakB, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak B Trap" +::= { gstTrapPrefix 11413 } + +gstCtrl3ChDeciAmpsBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDeciAmpsB, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps B Trap" +::= { gstTrapPrefix 11414 } + +gstCtrl3ChDeciAmpsPeakBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDeciAmpsPeakB, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak B Trap" +::= { gstTrapPrefix 11415 } + +gstCtrl3ChRealPowerBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChRealPowerB, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power B Trap" +::= { gstTrapPrefix 11416 } + +gstCtrl3ChApparentPowerBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChApparentPowerB, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power B Trap" +::= { gstTrapPrefix 11417 } + +gstCtrl3ChPowerFactorBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChPowerFactorB, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor B Trap" +::= { gstTrapPrefix 11418 } + +gstCtrl3ChVoltsCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChVoltsC, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts C Trap" +::= { gstTrapPrefix 11419 } + +gstCtrl3ChVoltPeakCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChVoltPeakC, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak C Trap" +::= { gstTrapPrefix 11420 } + +gstCtrl3ChDeciAmpsCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDeciAmpsC, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps C Trap" +::= { gstTrapPrefix 11421 } + +gstCtrl3ChDeciAmpsPeakCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChDeciAmpsPeakC, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak C Trap" +::= { gstTrapPrefix 11422 } + +gstCtrl3ChRealPowerCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChRealPowerC, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power C Trap" +::= { gstTrapPrefix 11423 } + +gstCtrl3ChApparentPowerCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChApparentPowerC, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power C Trap" +::= { gstTrapPrefix 11424 } + +gstCtrl3ChPowerFactorCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChPowerFactorC, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor C Trap" +::= { gstTrapPrefix 11425 } + +gstCtrlGrpAmpsANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsA, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group A DeciAmps Trap" +::= { gstTrapPrefix 11505 } + +gstCtrlGrpAmpsBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsB, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group B DeciAmps Trap" +::= { gstTrapPrefix 11506 } + +gstCtrlGrpAmpsCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsC, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group C DeciAmps Trap" +::= { gstTrapPrefix 11507 } + +gstCtrlGrpAmpsDNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsD, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group D DeciAmps Trap" +::= { gstTrapPrefix 11508 } + +gstCtrlGrpAmpsENOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsE, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group E DeciAmps Trap" +::= { gstTrapPrefix 11509 } + +gstCtrlGrpAmpsFNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsF, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group F DeciAmps Trap" +::= { gstTrapPrefix 11510 } + +gstCtrlGrpAmpsGNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsG, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group G DeciAmps Trap" +::= { gstTrapPrefix 11511 } + +gstCtrlGrpAmpsHNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsH, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group H DeciAmps Trap" +::= { gstTrapPrefix 11512 } + +gstCtrlGrpAmpsAVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsAVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "AVolts Trip Trap" +::= { gstTrapPrefix 11513 } + +gstCtrlGrpAmpsBVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsBVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "BVolts Trip Trap" +::= { gstTrapPrefix 11514 } + +gstCtrlGrpAmpsCVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsCVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "CVolts Trip Trap" +::= { gstTrapPrefix 11515 } + +gstCtrlGrpAmpsDVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsDVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DVolts Trip Trap" +::= { gstTrapPrefix 11516 } + +gstCtrlGrpAmpsEVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsEVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "EVolts Trip Trap" +::= { gstTrapPrefix 11517 } + +gstCtrlGrpAmpsFVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsFVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "FVolts Trip Trap" +::= { gstTrapPrefix 11518 } + +gstCtrlGrpAmpsGVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsGVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "GVolts Trip Trap" +::= { gstTrapPrefix 11519 } + +gstCtrlGrpAmpsHVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsHVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "HVolts Trip Trap" +::= { gstTrapPrefix 11520 } + +gstCtrlGrpAmpsINOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsI, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group I DeciAmps Trap" +::= { gstTrapPrefix 11521 } + +gstCtrlGrpAmpsJNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsJ, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group J DeciAmps Trap" +::= { gstTrapPrefix 11522 } + +gstCtrlGrpAmpsKNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsK, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group K DeciAmps Trap" +::= { gstTrapPrefix 11523 } + +gstCtrlGrpAmpsLNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsL, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group L DeciAmps Trap" +::= { gstTrapPrefix 11524 } + +gstCtrlGrpAmpsMNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsM, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group M DeciAmps Trap" +::= { gstTrapPrefix 11525 } + +gstCtrlGrpAmpsNNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsN, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group N DeciAmps Trap" +::= { gstTrapPrefix 11526 } + +gstCtrlGrpAmpsONOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsO, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group O DeciAmps Trap" +::= { gstTrapPrefix 11527 } + +gstCtrlGrpAmpsPNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsP, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group P DeciAmps Trap" +::= { gstTrapPrefix 11528 } + +gstCtrlGrpAmpsIVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsIVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "IVolts Trip Trap" +::= { gstTrapPrefix 11529 } + +gstCtrlGrpAmpsJVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsJVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "JVolts Trip Trap" +::= { gstTrapPrefix 11530 } + +gstCtrlGrpAmpsKVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsKVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "KVolts Trip Trap" +::= { gstTrapPrefix 11531 } + +gstCtrlGrpAmpsLVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsLVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "LVolts Trip Trap" +::= { gstTrapPrefix 11532 } + +gstCtrlGrpAmpsMVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsMVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "MVolts Trip Trap" +::= { gstTrapPrefix 11533 } + +gstCtrlGrpAmpsNVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsNVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "NVolts Trip Trap" +::= { gstTrapPrefix 11534 } + +gstCtrlGrpAmpsOVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsOVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "OVolts Trip Trap" +::= { gstTrapPrefix 11535 } + +gstCtrlGrpAmpsPVoltsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsPVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "PVolts Trip Trap" +::= { gstTrapPrefix 11536 } + +gstCtrlOutletPendingNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlOutletPending, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Pending Trip Trap" +::= { gstTrapPrefix 11605 } + +gstCtrlOutletDeciAmpsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlOutletDeciAmps, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Outlet DeciAmps Trap" +::= { gstTrapPrefix 11606 } + +gstCtrlOutletGroupNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlOutletGroup, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group Trip Trap" +::= { gstTrapPrefix 11607 } + +gstCtrlOutletUpDelayNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlOutletUpDelay, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "UpDelay Trip Trap" +::= { gstTrapPrefix 11608 } + +gstCtrlOutletDwnDelayNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlOutletDwnDelay, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DwnDelay Trip Trap" +::= { gstTrapPrefix 11609 } + +gstCtrlOutletRbtDurationNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlOutletRbtDuration, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "RbtDuration Trip Trap" +::= { gstTrapPrefix 11610 } + +gstCtrlOutletURLNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlOutletURL, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "URL Trip Trap" +::= { gstTrapPrefix 11611 } + +gstCtrlOutletPOAActionNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlOutletPOAAction, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "POAAction Trip Trap" +::= { gstTrapPrefix 11612 } + +gstCtrlOutletPOADelayNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlOutletPOADelay, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "POADelay Trip Trap" +::= { gstTrapPrefix 11613 } + +gstCtrlOutletkWattHrsNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlOutletkWattHrs, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "kWattHrs Trip Trap" +::= { gstTrapPrefix 11614 } + +gstCtrlOutletPowerNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlOutletPower, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Trip Trap" +::= { gstTrapPrefix 11615 } + +gstCtrlOutletRbtDelayNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlOutletRbtDelay, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "RbtDelay Trip Trap" +::= { gstTrapPrefix 11616 } + +gstCtrlOutletStatusTimeNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrlOutletStatusTime, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "StatusTime Trip Trap" +::= { gstTrapPrefix 11617 } + +gstDewPointSensorTempCNOTIFY NOTIFICATION-TYPE +OBJECTS { dewPointSensorTempC, dewPointSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Dew Point Sensor - Temperature Trap" +::= { gstTrapPrefix 11705 } + +gstDewPointSensorTempFNOTIFY NOTIFICATION-TYPE +OBJECTS { dewPointSensorTempF, dewPointSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Dew Point Sensor - Temperature Trap" +::= { gstTrapPrefix 11706 } + +gstDewPointSensorHumidityNOTIFY NOTIFICATION-TYPE +OBJECTS { dewPointSensorHumidity, dewPointSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Dew Point Sensor - Humidity" +::= { gstTrapPrefix 11707 } + +gstDewPointSensorDewPointCNOTIFY NOTIFICATION-TYPE +OBJECTS { dewPointSensorDewPointC, dewPointSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Dew Point Sensor - Dew Point Trap" +::= { gstTrapPrefix 11708 } + +gstDewPointSensorDewPointFNOTIFY NOTIFICATION-TYPE +OBJECTS { dewPointSensorDewPointF, dewPointSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Dew Point Sensor - Dew Point Trap" +::= { gstTrapPrefix 11709 } + +gstDigitalSensorDigitalNOTIFY NOTIFICATION-TYPE +OBJECTS { digitalSensorDigital, digitalSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Digital sensor Trap" +::= { gstTrapPrefix 11805 } + +gstDstsVoltsANOTIFY NOTIFICATION-TYPE +OBJECTS { dstsVoltsA, dstsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "RMS Voltage of Side A Set Point Sensor Trap" +::= { gstTrapPrefix 11905 } + +gstDstsDeciAmpsANOTIFY NOTIFICATION-TYPE +OBJECTS { dstsDeciAmpsA, dstsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "RMS Current of Side A Set Point Sensor Trap" +::= { gstTrapPrefix 11906 } + +gstDstsVoltsBNOTIFY NOTIFICATION-TYPE +OBJECTS { dstsVoltsB, dstsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "RMS Voltage of Side B Set Point Sensor Trap" +::= { gstTrapPrefix 11907 } + +gstDstsDeciAmpsBNOTIFY NOTIFICATION-TYPE +OBJECTS { dstsDeciAmpsB, dstsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "RMS Current of Side B Set Point Sensor Trap" +::= { gstTrapPrefix 11908 } + +gstDstsSourceAActiveNOTIFY NOTIFICATION-TYPE +OBJECTS { dstsSourceAActive, dstsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Source A Active Set Point Sensor Trap" +::= { gstTrapPrefix 11909 } + +gstDstsSourceBActiveNOTIFY NOTIFICATION-TYPE +OBJECTS { dstsSourceBActive, dstsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Source B Active Set Point Sensor Trap" +::= { gstTrapPrefix 11910 } + +gstDstsPowerStatusANOTIFY NOTIFICATION-TYPE +OBJECTS { dstsPowerStatusA, dstsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Source A Power Qualilty Active Set Point Sensor Trap" +::= { gstTrapPrefix 11911 } + +gstDstsPowerStatusBNOTIFY NOTIFICATION-TYPE +OBJECTS { dstsPowerStatusB, dstsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Source B Power Qualilty Active Set Point Sensor Trap" +::= { gstTrapPrefix 11912 } + +gstDstsSourceATempCNOTIFY NOTIFICATION-TYPE +OBJECTS { dstsSourceATempC, dstsName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Source A Temp Sensor Trap" +::= { gstTrapPrefix 11913 } + +gstDstsSourceBTempCNOTIFY NOTIFICATION-TYPE +OBJECTS { dstsSourceBTempC, dstsName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Source B Temp Sensor Trap" +::= { gstTrapPrefix 11914 } + +gstCpmSensorStatusNOTIFY NOTIFICATION-TYPE +OBJECTS { cpmSensorStatus, cpmSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "City Power sensor Trap" +::= { gstTrapPrefix 12005 } + +gstSmokeAlarmStatusNOTIFY NOTIFICATION-TYPE +OBJECTS { smokeAlarmStatus, smokeAlarmName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Smoke alarm Trap" +::= { gstTrapPrefix 12105 } + +gstNeg48VdcSensorVoltageNOTIFY NOTIFICATION-TYPE +OBJECTS { neg48VdcSensorVoltage, neg48VdcSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "-48Vdc Sensor Trap" +::= { gstTrapPrefix 12205 } + +gstPos30VdcSensorVoltageNOTIFY NOTIFICATION-TYPE +OBJECTS { pos30VdcSensorVoltage, pos30VdcSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "30Vdc Sensor Trap" +::= { gstTrapPrefix 12305 } + +gstAnalogSensorAnalogNOTIFY NOTIFICATION-TYPE +OBJECTS { analogSensorAnalog, analogSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Analog Sensor Trap" +::= { gstTrapPrefix 12405 } + +gstCtrl3ChIECkWattHrsANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECkWattHrsA, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours A Trap" +::= { gstTrapPrefix 12505 } + +gstCtrl3ChIECVoltsANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECVoltsA, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts A Trap" +::= { gstTrapPrefix 12506 } + +gstCtrl3ChIECVoltPeakANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECVoltPeakA, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak A Trap" +::= { gstTrapPrefix 12507 } + +gstCtrl3ChIECDeciAmpsANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECDeciAmpsA, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps A Trap" +::= { gstTrapPrefix 12508 } + +gstCtrl3ChIECDeciAmpsPeakANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECDeciAmpsPeakA, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak A Trap" +::= { gstTrapPrefix 12509 } + +gstCtrl3ChIECRealPowerANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECRealPowerA, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power A Trap" +::= { gstTrapPrefix 12510 } + +gstCtrl3ChIECApparentPowerANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECApparentPowerA, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power A Trap" +::= { gstTrapPrefix 12511 } + +gstCtrl3ChIECPowerFactorANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECPowerFactorA, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor A Trap" +::= { gstTrapPrefix 12512 } + +gstCtrl3ChIECkWattHrsBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECkWattHrsB, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours B Trap" +::= { gstTrapPrefix 12513 } + +gstCtrl3ChIECVoltsBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECVoltsB, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts B Trap" +::= { gstTrapPrefix 12514 } + +gstCtrl3ChIECVoltPeakBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECVoltPeakB, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak B Trap" +::= { gstTrapPrefix 12515 } + +gstCtrl3ChIECDeciAmpsBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECDeciAmpsB, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps B Trap" +::= { gstTrapPrefix 12516 } + +gstCtrl3ChIECDeciAmpsPeakBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECDeciAmpsPeakB, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak B Trap" +::= { gstTrapPrefix 12517 } + +gstCtrl3ChIECRealPowerBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECRealPowerB, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power B Trap" +::= { gstTrapPrefix 12518 } + +gstCtrl3ChIECApparentPowerBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECApparentPowerB, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power B Trap" +::= { gstTrapPrefix 12519 } + +gstCtrl3ChIECPowerFactorBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECPowerFactorB, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor B Trap" +::= { gstTrapPrefix 12520 } + +gstCtrl3ChIECkWattHrsCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECkWattHrsC, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours C Trap" +::= { gstTrapPrefix 12521 } + +gstCtrl3ChIECVoltsCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECVoltsC, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts C Trap" +::= { gstTrapPrefix 12522 } + +gstCtrl3ChIECVoltPeakCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECVoltPeakC, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak C Trap" +::= { gstTrapPrefix 12523 } + +gstCtrl3ChIECDeciAmpsCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECDeciAmpsC, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps C Trap" +::= { gstTrapPrefix 12524 } + +gstCtrl3ChIECDeciAmpsPeakCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECDeciAmpsPeakC, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak C Trap" +::= { gstTrapPrefix 12525 } + +gstCtrl3ChIECRealPowerCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECRealPowerC, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power C Trap" +::= { gstTrapPrefix 12526 } + +gstCtrl3ChIECApparentPowerCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECApparentPowerC, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power C Trap" +::= { gstTrapPrefix 12527 } + +gstCtrl3ChIECPowerFactorCNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECPowerFactorC, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor C Trap" +::= { gstTrapPrefix 12528 } + +gstCtrl3ChIECkWattHrsTotalNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECkWattHrsTotal, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours Total Trap" +::= { gstTrapPrefix 12529 } + +gstCtrl3ChIECRealPowerTotalNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECRealPowerTotal, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Watts Total Trap" +::= { gstTrapPrefix 12530 } + +gstClimateRelayTempCNOTIFY NOTIFICATION-TYPE +OBJECTS { climateRelayTempC, climateRelayName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay Temperature Sensor Trap" +::= { gstTrapPrefix 12605 } + +gstClimateRelayTempFNOTIFY NOTIFICATION-TYPE +OBJECTS { climateRelayTempF, climateRelayName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay Temperature Sensor Trap" +::= { gstTrapPrefix 12606 } + +gstClimateRelayIO1NOTIFY NOTIFICATION-TYPE +OBJECTS { climateRelayIO1, climateRelayName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO1 Sensor Trap" +::= { gstTrapPrefix 12607 } + +gstClimateRelayIO2NOTIFY NOTIFICATION-TYPE +OBJECTS { climateRelayIO2, climateRelayName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO2 Sensor Trap" +::= { gstTrapPrefix 12608 } + +gstClimateRelayIO3NOTIFY NOTIFICATION-TYPE +OBJECTS { climateRelayIO3, climateRelayName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO3 Sensor Trap" +::= { gstTrapPrefix 12609 } + +gstClimateRelayIO4NOTIFY NOTIFICATION-TYPE +OBJECTS { climateRelayIO4, climateRelayName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO4 Sensor Trap" +::= { gstTrapPrefix 12610 } + +gstClimateRelayIO5NOTIFY NOTIFICATION-TYPE +OBJECTS { climateRelayIO5, climateRelayName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO5 Sensor Trap" +::= { gstTrapPrefix 12611 } + +gstClimateRelayIO6NOTIFY NOTIFICATION-TYPE +OBJECTS { climateRelayIO6, climateRelayName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO6 Sensor Trap" +::= { gstTrapPrefix 12612 } + +gstAirSpeedSwitchSensorAirSpeedNOTIFY NOTIFICATION-TYPE +OBJECTS { airSpeedSwitchSensorAirSpeed, airSpeedSwitchSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Air Speed Switch Trap" +::= { gstTrapPrefix 12805 } + +gstPowerDMDeciAmps1NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps1, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129153 } + +gstPowerDMDeciAmps2NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps2, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129154 } + +gstPowerDMDeciAmps3NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps3, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129155 } + +gstPowerDMDeciAmps4NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps4, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129156 } + +gstPowerDMDeciAmps5NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps5, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129157 } + +gstPowerDMDeciAmps6NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps6, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129158 } + +gstPowerDMDeciAmps7NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps7, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129159 } + +gstPowerDMDeciAmps8NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps8, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129160 } + +gstPowerDMDeciAmps9NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps9, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129161 } + +gstPowerDMDeciAmps10NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps10, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129162 } + +gstPowerDMDeciAmps11NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps11, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129163 } + +gstPowerDMDeciAmps12NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps12, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129164 } + +gstPowerDMDeciAmps13NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps13, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129165 } + +gstPowerDMDeciAmps14NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps14, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129166 } + +gstPowerDMDeciAmps15NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps15, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129167 } + +gstPowerDMDeciAmps16NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps16, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129168 } + +gstPowerDMDeciAmps17NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps17, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129169 } + +gstPowerDMDeciAmps18NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps18, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129170 } + +gstPowerDMDeciAmps19NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps19, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129171 } + +gstPowerDMDeciAmps20NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps20, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129172 } + +gstPowerDMDeciAmps21NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps21, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129173 } + +gstPowerDMDeciAmps22NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps22, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129174 } + +gstPowerDMDeciAmps23NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps23, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129175 } + +gstPowerDMDeciAmps24NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps24, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129176 } + +gstPowerDMDeciAmps25NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps25, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129177 } + +gstPowerDMDeciAmps26NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps26, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129178 } + +gstPowerDMDeciAmps27NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps27, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129179 } + +gstPowerDMDeciAmps28NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps28, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129180 } + +gstPowerDMDeciAmps29NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps29, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129181 } + +gstPowerDMDeciAmps30NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps30, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129182 } + +gstPowerDMDeciAmps31NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps31, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129183 } + +gstPowerDMDeciAmps32NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps32, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129184 } + +gstPowerDMDeciAmps33NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps33, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129185 } + +gstPowerDMDeciAmps34NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps34, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129186 } + +gstPowerDMDeciAmps35NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps35, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129187 } + +gstPowerDMDeciAmps36NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps36, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129188 } + +gstPowerDMDeciAmps37NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps37, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129189 } + +gstPowerDMDeciAmps38NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps38, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129190 } + +gstPowerDMDeciAmps39NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps39, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129191 } + +gstPowerDMDeciAmps40NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps40, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129192 } + +gstPowerDMDeciAmps41NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps41, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129193 } + +gstPowerDMDeciAmps42NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps42, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129194 } + +gstPowerDMDeciAmps43NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps43, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129195 } + +gstPowerDMDeciAmps44NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps44, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129196 } + +gstPowerDMDeciAmps45NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps45, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129197 } + +gstPowerDMDeciAmps46NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps46, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129198 } + +gstPowerDMDeciAmps47NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps47, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129199 } + +gstPowerDMDeciAmps48NOTIFY NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps48, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Trap" +::= { gstTrapPrefix 129200 } + +gstIoExpanderIO1NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO1, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO1 Sensor Trap" +::= { gstTrapPrefix 13037 } + +gstIoExpanderIO2NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO2, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO2 Sensor Trap" +::= { gstTrapPrefix 13038 } + +gstIoExpanderIO3NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO3, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO3 Sensor Trap" +::= { gstTrapPrefix 13039 } + +gstIoExpanderIO4NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO4, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO4 Sensor Trap" +::= { gstTrapPrefix 13040 } + +gstIoExpanderIO5NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO5, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO5 Sensor Trap" +::= { gstTrapPrefix 13041 } + +gstIoExpanderIO6NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO6, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO6 Sensor Trap" +::= { gstTrapPrefix 13042 } + +gstIoExpanderIO7NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO7, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO7 Sensor Trap" +::= { gstTrapPrefix 13043 } + +gstIoExpanderIO8NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO8, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO8 Sensor Trap" +::= { gstTrapPrefix 13044 } + +gstIoExpanderIO9NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO9, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO9 Sensor Trap" +::= { gstTrapPrefix 13045 } + +gstIoExpanderIO10NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO10, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO10 Sensor Trap" +::= { gstTrapPrefix 13046 } + +gstIoExpanderIO11NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO11, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO11 Sensor Trap" +::= { gstTrapPrefix 13047 } + +gstIoExpanderIO12NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO12, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO12 Sensor Trap" +::= { gstTrapPrefix 13048 } + +gstIoExpanderIO13NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO13, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO13 Sensor Trap" +::= { gstTrapPrefix 13049 } + +gstIoExpanderIO14NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO14, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO14 Sensor Trap" +::= { gstTrapPrefix 13050 } + +gstIoExpanderIO15NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO15, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO15 Sensor Trap" +::= { gstTrapPrefix 13051 } + +gstIoExpanderIO16NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO16, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO16 Sensor Trap" +::= { gstTrapPrefix 13052 } + +gstIoExpanderIO17NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO17, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO17 Sensor Trap" +::= { gstTrapPrefix 13053 } + +gstIoExpanderIO18NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO18, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO18 Sensor Trap" +::= { gstTrapPrefix 13054 } + +gstIoExpanderIO19NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO19, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO19 Sensor Trap" +::= { gstTrapPrefix 13055 } + +gstIoExpanderIO20NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO20, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO20 Sensor Trap" +::= { gstTrapPrefix 13056 } + +gstIoExpanderIO21NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO21, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO21 Sensor Trap" +::= { gstTrapPrefix 13057 } + +gstIoExpanderIO22NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO22, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO22 Sensor Trap" +::= { gstTrapPrefix 13058 } + +gstIoExpanderIO23NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO23, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO23 Sensor Trap" +::= { gstTrapPrefix 13059 } + +gstIoExpanderIO24NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO24, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO24 Sensor Trap" +::= { gstTrapPrefix 13060 } + +gstIoExpanderIO25NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO25, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO25 Sensor Trap" +::= { gstTrapPrefix 13061 } + +gstIoExpanderIO26NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO26, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO26 Sensor Trap" +::= { gstTrapPrefix 13062 } + +gstIoExpanderIO27NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO27, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO27 Sensor Trap" +::= { gstTrapPrefix 13063 } + +gstIoExpanderIO28NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO28, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO28 Sensor Trap" +::= { gstTrapPrefix 13064 } + +gstIoExpanderIO29NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO29, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO29 Sensor Trap" +::= { gstTrapPrefix 13065 } + +gstIoExpanderIO30NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO30, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO30 Sensor Trap" +::= { gstTrapPrefix 13066 } + +gstIoExpanderIO31NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO31, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO31 Sensor Trap" +::= { gstTrapPrefix 13067 } + +gstIoExpanderIO32NOTIFY NOTIFICATION-TYPE +OBJECTS { ioExpanderIO32, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO32 Sensor Trap" +::= { gstTrapPrefix 13068 } + +gstT3hdSensorIntTempCNOTIFY NOTIFICATION-TYPE +OBJECTS { t3hdSensorIntTempC, t3hdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - Internal Temperature C Trap" +::= { gstTrapPrefix 13106 } + +gstT3hdSensorIntTempFNOTIFY NOTIFICATION-TYPE +OBJECTS { t3hdSensorIntTempF, t3hdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - Internal Temperature F Trap" +::= { gstTrapPrefix 13107 } + +gstT3hdSensorIntHumidityNOTIFY NOTIFICATION-TYPE +OBJECTS { t3hdSensorIntHumidity, t3hdSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - Internal Humidity Trap" +::= { gstTrapPrefix 13108 } + +gstT3hdSensorIntDewPointCNOTIFY NOTIFICATION-TYPE +OBJECTS { t3hdSensorIntDewPointC, t3hdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - Internal Dew Point C Trap" +::= { gstTrapPrefix 13109 } + +gstT3hdSensorIntDewPointFNOTIFY NOTIFICATION-TYPE +OBJECTS { t3hdSensorIntDewPointF, t3hdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - Internal Dew Point F Trap" +::= { gstTrapPrefix 13110 } + +gstT3hdSensorExt1TempCNOTIFY NOTIFICATION-TYPE +OBJECTS { t3hdSensorExt1TempC, t3hdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - External 1 Temperature C Trap" +::= { gstTrapPrefix 13113 } + +gstT3hdSensorExt1TempFNOTIFY NOTIFICATION-TYPE +OBJECTS { t3hdSensorExt1TempF, t3hdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - External 1 Temperature F Trap" +::= { gstTrapPrefix 13114 } + +gstT3hdSensorExt2TempCNOTIFY NOTIFICATION-TYPE +OBJECTS { t3hdSensorExt2TempC, t3hdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - External 2 Temperature C Trap" +::= { gstTrapPrefix 13117 } + +gstT3hdSensorExt2TempFNOTIFY NOTIFICATION-TYPE +OBJECTS { t3hdSensorExt2TempF, t3hdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - External 2 Temperature F Trap" +::= { gstTrapPrefix 13118 } + +gstThdSensorTempCNOTIFY NOTIFICATION-TYPE +OBJECTS { thdSensorTempC, thdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "THD - Temperature C Trap" +::= { gstTrapPrefix 13205 } + +gstThdSensorTempFNOTIFY NOTIFICATION-TYPE +OBJECTS { thdSensorTempF, thdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "THD - Temperature F Trap" +::= { gstTrapPrefix 13206 } + +gstThdSensorHumidityNOTIFY NOTIFICATION-TYPE +OBJECTS { thdSensorHumidity, thdSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "THD - Humidity Trap" +::= { gstTrapPrefix 13207 } + +gstThdSensorDewPointCNOTIFY NOTIFICATION-TYPE +OBJECTS { thdSensorDewPointC, thdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "THD - Dew Point C Trap" +::= { gstTrapPrefix 13208 } + +gstThdSensorDewPointFNOTIFY NOTIFICATION-TYPE +OBJECTS { thdSensorDewPointF, thdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "THD - Dew Point F Trap" +::= { gstTrapPrefix 13209 } + +gstPos60VdcSensorVoltageNOTIFY NOTIFICATION-TYPE +OBJECTS { pos60VdcSensorVoltage, pos60VdcSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "60Vdc Sensor Trap" +::= { gstTrapPrefix 13305 } + +gstCtrl2CirTotkWattHrsTotNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotkWattHrsTot, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours Total Trap" +::= { gstTrapPrefix 13405 } + +gstCtrl2CirTotVoltsTotNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotVoltsTot, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts A Trap" +::= { gstTrapPrefix 13406 } + +gstCtrl2CirTotVoltPeakTotNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotVoltPeakTot, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak Total Trap" +::= { gstTrapPrefix 13407 } + +gstCtrl2CirTotDeciAmpsTotNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotDeciAmpsTot, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Total Trap" +::= { gstTrapPrefix 13408 } + +gstCtrl2CirTotDeciAmpsPeakTotNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotDeciAmpsPeakTot, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak Total Trap" +::= { gstTrapPrefix 13409 } + +gstCtrl2CirTotRealPowerTotNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotRealPowerTot, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power Total Trap" +::= { gstTrapPrefix 13410 } + +gstCtrl2CirTotApparentPowerTotNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotApparentPowerTot, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power Total Trap" +::= { gstTrapPrefix 13411 } + +gstCtrl2CirTotPowerFactorTotNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotPowerFactorTot, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor Total Trap" +::= { gstTrapPrefix 13412 } + +gstCtrl2CirTotkWattHrsANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotkWattHrsA, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours A Trap" +::= { gstTrapPrefix 13413 } + +gstCtrl2CirTotVoltsANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotVoltsA, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts A Trap" +::= { gstTrapPrefix 13414 } + +gstCtrl2CirTotVoltPeakANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotVoltPeakA, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak A Trap" +::= { gstTrapPrefix 13415 } + +gstCtrl2CirTotDeciAmpsANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotDeciAmpsA, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps A Trap" +::= { gstTrapPrefix 13416 } + +gstCtrl2CirTotDeciAmpsPeakANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotDeciAmpsPeakA, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak A Trap" +::= { gstTrapPrefix 13417 } + +gstCtrl2CirTotRealPowerANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotRealPowerA, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power A Trap" +::= { gstTrapPrefix 13418 } + +gstCtrl2CirTotApparentPowerANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotApparentPowerA, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power A Trap" +::= { gstTrapPrefix 13419 } + +gstCtrl2CirTotPowerFactorANOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotPowerFactorA, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor A Trap" +::= { gstTrapPrefix 13420 } + +gstCtrl2CirTotkWattHrsBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotkWattHrsB, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours B Trap" +::= { gstTrapPrefix 13421 } + +gstCtrl2CirTotVoltsBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotVoltsB, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts B Trap" +::= { gstTrapPrefix 13422 } + +gstCtrl2CirTotVoltPeakBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotVoltPeakB, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak B Trap" +::= { gstTrapPrefix 13423 } + +gstCtrl2CirTotDeciAmpsBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotDeciAmpsB, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps B Trap" +::= { gstTrapPrefix 13424 } + +gstCtrl2CirTotDeciAmpsPeakBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotDeciAmpsPeakB, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak B Trap" +::= { gstTrapPrefix 13425 } + +gstCtrl2CirTotRealPowerBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotRealPowerB, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power B Trap" +::= { gstTrapPrefix 13426 } + +gstCtrl2CirTotApparentPowerBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotApparentPowerB, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power B Trap" +::= { gstTrapPrefix 13427 } + +gstCtrl2CirTotPowerFactorBNOTIFY NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotPowerFactorB, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor B Trap" +::= { gstTrapPrefix 13428 } + +gstSc10ControlModeNOTIFY NOTIFICATION-TYPE +OBJECTS { sc10ControlMode, sc10Name, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "SC10 Control Mode Sensor Trap" +::= { gstTrapPrefix 13505 } + +gstSc10SetpointCNOTIFY NOTIFICATION-TYPE +OBJECTS { sc10SetpointC, sc10Name, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "SC10 Temp Set Point Sensor Trap" +::= { gstTrapPrefix 13506 } + +gstSc10SetpointFNOTIFY NOTIFICATION-TYPE +OBJECTS { sc10SetpointF, sc10Name, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "SC10 Temp Set Point Sensor Trap" +::= { gstTrapPrefix 13507 } + +gstSc10TempCNOTIFY NOTIFICATION-TYPE +OBJECTS { sc10TempC, sc10Name, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "SC10 Internal Temp Sensor Trap" +::= { gstTrapPrefix 13508 } + +gstSc10TempFNOTIFY NOTIFICATION-TYPE +OBJECTS { sc10TempF, sc10Name, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "SC10 Internal Temp Sensor Trap" +::= { gstTrapPrefix 13509 } + +gstSc10CapacityNOTIFY NOTIFICATION-TYPE +OBJECTS { sc10Capacity, sc10Name, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "SC10 Fan Speed Sensor Trap" +::= { gstTrapPrefix 13510 } + +gstClimateTempCCLEAR NOTIFICATION-TYPE +OBJECTS { climateTempC, climateName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Temperature Sensor Clear Trap" +::= { gstTrapPrefix 20205 } + +gstClimateTempFCLEAR NOTIFICATION-TYPE +OBJECTS { climateTempF, climateName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Temperature Sensor Clear Trap" +::= { gstTrapPrefix 20206 } + +gstClimateHumidityCLEAR NOTIFICATION-TYPE +OBJECTS { climateHumidity, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Humidity Sensor Clear Trap" +::= { gstTrapPrefix 20207 } + +gstClimateLightCLEAR NOTIFICATION-TYPE +OBJECTS { climateLight, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Light Sensor Clear Trap" +::= { gstTrapPrefix 20208 } + +gstClimateAirflowCLEAR NOTIFICATION-TYPE +OBJECTS { climateAirflow, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Air Flow Sensor Clear Trap" +::= { gstTrapPrefix 20209 } + +gstClimateSoundCLEAR NOTIFICATION-TYPE +OBJECTS { climateSound, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Sound Sensor Clear Trap" +::= { gstTrapPrefix 20210 } + +gstClimateIO1CLEAR NOTIFICATION-TYPE +OBJECTS { climateIO1, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate IO1 Sensor Clear Trap" +::= { gstTrapPrefix 20211 } + +gstClimateIO2CLEAR NOTIFICATION-TYPE +OBJECTS { climateIO2, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate IO2 Sensor Clear Trap" +::= { gstTrapPrefix 20212 } + +gstClimateIO3CLEAR NOTIFICATION-TYPE +OBJECTS { climateIO3, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate IO3 Sensor Clear Trap" +::= { gstTrapPrefix 20213 } + +gstClimateVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { climateVolts, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Volts Clear Trap" +::= { gstTrapPrefix 20214 } + +gstClimateVoltPeakCLEAR NOTIFICATION-TYPE +OBJECTS { climateVoltPeak, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Volts Peak Clear Trap" +::= { gstTrapPrefix 20215 } + +gstClimateDeciAmpsACLEAR NOTIFICATION-TYPE +OBJECTS { climateDeciAmpsA, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Amps A Clear Trap" +::= { gstTrapPrefix 20216 } + +gstClimateDeciAmpPeakACLEAR NOTIFICATION-TYPE +OBJECTS { climateDeciAmpPeakA, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Amp Peak A Clear Trap" +::= { gstTrapPrefix 20217 } + +gstClimateRealPowerACLEAR NOTIFICATION-TYPE +OBJECTS { climateRealPowerA, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Real Power A Clear Trap" +::= { gstTrapPrefix 20218 } + +gstClimateApparentPowerACLEAR NOTIFICATION-TYPE +OBJECTS { climateApparentPowerA, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Apparent Power A Clear Trap" +::= { gstTrapPrefix 20219 } + +gstClimatePowerFactorACLEAR NOTIFICATION-TYPE +OBJECTS { climatePowerFactorA, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Power Factor A Clear Trap" +::= { gstTrapPrefix 20220 } + +gstClimateDeciAmpsBCLEAR NOTIFICATION-TYPE +OBJECTS { climateDeciAmpsB, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Amps B Clear Trap" +::= { gstTrapPrefix 20221 } + +gstClimateDeciAmpPeakBCLEAR NOTIFICATION-TYPE +OBJECTS { climateDeciAmpPeakB, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Amp Peak B Clear Trap" +::= { gstTrapPrefix 20222 } + +gstClimateRealPowerBCLEAR NOTIFICATION-TYPE +OBJECTS { climateRealPowerB, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Real Power B Clear Trap" +::= { gstTrapPrefix 20223 } + +gstClimateApparentPowerBCLEAR NOTIFICATION-TYPE +OBJECTS { climateApparentPowerB, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Apparent Power B Clear Trap" +::= { gstTrapPrefix 20224 } + +gstClimatePowerFactorBCLEAR NOTIFICATION-TYPE +OBJECTS { climatePowerFactorB, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Power Factor B Clear Trap" +::= { gstTrapPrefix 20225 } + +gstClimateDeciAmpsCCLEAR NOTIFICATION-TYPE +OBJECTS { climateDeciAmpsC, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Amps C Clear Trap" +::= { gstTrapPrefix 20226 } + +gstClimateDeciAmpPeakCCLEAR NOTIFICATION-TYPE +OBJECTS { climateDeciAmpPeakC, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Amp Peak C Clear Trap" +::= { gstTrapPrefix 20227 } + +gstClimateRealPowerCCLEAR NOTIFICATION-TYPE +OBJECTS { climateRealPowerC, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Real Power C Clear Trap" +::= { gstTrapPrefix 20228 } + +gstClimateApparentPowerCCLEAR NOTIFICATION-TYPE +OBJECTS { climateApparentPowerC, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Apparent Power C Clear Trap" +::= { gstTrapPrefix 20229 } + +gstClimatePowerFactorCCLEAR NOTIFICATION-TYPE +OBJECTS { climatePowerFactorC, climateName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Power Factor C Clear Trap" +::= { gstTrapPrefix 20230 } + +gstClimateDewPointCCLEAR NOTIFICATION-TYPE +OBJECTS { climateDewPointC, climateName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Dew Point Sensor Clear Trap" +::= { gstTrapPrefix 20231 } + +gstClimateDewPointFCLEAR NOTIFICATION-TYPE +OBJECTS { climateDewPointF, climateName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Dew Point Sensor Clear Trap" +::= { gstTrapPrefix 20232 } + +gstPowMonkWattHrsCLEAR NOTIFICATION-TYPE +OBJECTS { powMonkWattHrs, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours Clear Trap" +::= { gstTrapPrefix 20305 } + +gstPowMonVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { powMonVolts, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Clear Trap" +::= { gstTrapPrefix 20306 } + +gstPowMonVoltMaxCLEAR NOTIFICATION-TYPE +OBJECTS { powMonVoltMax, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Max Clear Trap" +::= { gstTrapPrefix 20307 } + +gstPowMonVoltMinCLEAR NOTIFICATION-TYPE +OBJECTS { powMonVoltMin, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Min Clear Trap" +::= { gstTrapPrefix 20308 } + +gstPowMonVoltPeakCLEAR NOTIFICATION-TYPE +OBJECTS { powMonVoltPeak, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volt Peak Clear Trap" +::= { gstTrapPrefix 20309 } + +gstPowMonDeciAmpsCLEAR NOTIFICATION-TYPE +OBJECTS { powMonDeciAmps, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DeciAmps Clear Trap" +::= { gstTrapPrefix 20310 } + +gstPowMonRealPowerCLEAR NOTIFICATION-TYPE +OBJECTS { powMonRealPower, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power Clear Trap" +::= { gstTrapPrefix 20311 } + +gstPowMonApparentPowerCLEAR NOTIFICATION-TYPE +OBJECTS { powMonApparentPower, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power Clear Trap" +::= { gstTrapPrefix 20312 } + +gstPowMonPowerFactorCLEAR NOTIFICATION-TYPE +OBJECTS { powMonPowerFactor, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor Clear Trap" +::= { gstTrapPrefix 20313 } + +gstPowMonOutlet1CLEAR NOTIFICATION-TYPE +OBJECTS { powMonOutlet1, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Outlet1 Clear Trap" +::= { gstTrapPrefix 20314 } + +gstPowMonOutlet2CLEAR NOTIFICATION-TYPE +OBJECTS { powMonOutlet2, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Outlet2 Clear Trap" +::= { gstTrapPrefix 20315 } + +gstPowMonOutlet1StatusTimeCLEAR NOTIFICATION-TYPE +OBJECTS { powMonOutlet1StatusTime, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Outlet1StatusTime Clear Trap" +::= { gstTrapPrefix 20316 } + +gstPowMonOutlet2StatusTimeCLEAR NOTIFICATION-TYPE +OBJECTS { powMonOutlet2StatusTime, powMonName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Outlet2StatusTime Clear Trap" +::= { gstTrapPrefix 20317 } + +gstTempSensorTempCCLEAR NOTIFICATION-TYPE +OBJECTS { tempSensorTempC, tempSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Temp Sensor - Temperature Clear Trap" +::= { gstTrapPrefix 20405 } + +gstTempSensorTempFCLEAR NOTIFICATION-TYPE +OBJECTS { tempSensorTempF, tempSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Temp Sensor - Temperature Clear Trap" +::= { gstTrapPrefix 20406 } + +gstAirFlowSensorTempCCLEAR NOTIFICATION-TYPE +OBJECTS { airFlowSensorTempC, airFlowSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Air Flow Sensor - Temperature Clear Trap" +::= { gstTrapPrefix 20505 } + +gstAirFlowSensorTempFCLEAR NOTIFICATION-TYPE +OBJECTS { airFlowSensorTempF, airFlowSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Air Flow Sensor - Temperature Clear Trap" +::= { gstTrapPrefix 20506 } + +gstAirFlowSensorFlowCLEAR NOTIFICATION-TYPE +OBJECTS { airFlowSensorFlow, airFlowSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Air Flow Sensor - Air Flow Clear Trap" +::= { gstTrapPrefix 20507 } + +gstAirFlowSensorHumidityCLEAR NOTIFICATION-TYPE +OBJECTS { airFlowSensorHumidity, airFlowSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Air Flow Sensor - Humidity Clear Trap" +::= { gstTrapPrefix 20508 } + +gstAirFlowSensorDewPointCCLEAR NOTIFICATION-TYPE +OBJECTS { airFlowSensorDewPointC, airFlowSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Air Flow Sensor - Dew Point Clear Trap" +::= { gstTrapPrefix 20509 } + +gstAirFlowSensorDewPointFCLEAR NOTIFICATION-TYPE +OBJECTS { airFlowSensorDewPointF, airFlowSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Air Flow Sensor - Dew Point Clear Trap" +::= { gstTrapPrefix 20510 } + +gstCtrl3ChDELTADeciAmpsACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTADeciAmpsA, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps A Clear Trap" +::= { gstTrapPrefix 20606 } + +gstCtrl3ChDELTADeciAmpsBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTADeciAmpsB, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps B Clear Trap" +::= { gstTrapPrefix 20607 } + +gstCtrl3ChDELTADeciAmpsCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTADeciAmpsC, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps C Clear Trap" +::= { gstTrapPrefix 20608 } + +gstCtrl3ChDELTAkWattHrsTotalCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAkWattHrsTotal, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours Total Clear Trap" +::= { gstTrapPrefix 20609 } + +gstCtrl3ChDELTARealPowerTotalCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTARealPowerTotal, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Watts Total Clear Trap" +::= { gstTrapPrefix 20610 } + +gstCtrl3ChDELTAkWattHrsABCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAkWattHrsAB, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours A Clear Trap" +::= { gstTrapPrefix 20611 } + +gstCtrl3ChDELTAVoltsABCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAVoltsAB, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts AB Clear Trap" +::= { gstTrapPrefix 20612 } + +gstCtrl3ChDELTAVoltPeakABCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAVoltPeakAB, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak AB Clear Trap" +::= { gstTrapPrefix 20613 } + +gstCtrl3ChDELTARealPowerABCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTARealPowerAB, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power AB Clear Trap" +::= { gstTrapPrefix 20614 } + +gstCtrl3ChDELTAApparentPowerABCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAApparentPowerAB, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "VoltAmps AB Clear Trap" +::= { gstTrapPrefix 20615 } + +gstCtrl3ChDELTAPowerFactorABCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAPowerFactorAB, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor AB Clear Trap" +::= { gstTrapPrefix 20616 } + +gstCtrl3ChDELTAkWattHrsBCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAkWattHrsBC, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours BC Clear Trap" +::= { gstTrapPrefix 20617 } + +gstCtrl3ChDELTAVoltsBCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAVoltsBC, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts BC Clear Trap" +::= { gstTrapPrefix 20618 } + +gstCtrl3ChDELTAVoltPeakBCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAVoltPeakBC, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak BC Clear Trap" +::= { gstTrapPrefix 20619 } + +gstCtrl3ChDELTARealPowerBCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTARealPowerBC, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power BC Clear Trap" +::= { gstTrapPrefix 20620 } + +gstCtrl3ChDELTAApparentPowerBCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAApparentPowerBC, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "VoltAmps BC Clear Trap" +::= { gstTrapPrefix 20621 } + +gstCtrl3ChDELTAPowerFactorBCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAPowerFactorBC, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor BC Clear Trap" +::= { gstTrapPrefix 20622 } + +gstCtrl3ChDELTAkWattHrsCACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAkWattHrsCA, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours CA Clear Trap" +::= { gstTrapPrefix 20623 } + +gstCtrl3ChDELTAVoltsCACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAVoltsCA, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts CA Clear Trap" +::= { gstTrapPrefix 20624 } + +gstCtrl3ChDELTAVoltPeakCACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAVoltPeakCA, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak CA Clear Trap" +::= { gstTrapPrefix 20625 } + +gstCtrl3ChDELTARealPowerCACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTARealPowerCA, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power CA Clear Trap" +::= { gstTrapPrefix 20626 } + +gstCtrl3ChDELTAApparentPowerCACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAApparentPowerCA, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "VoltAmps CA Clear Trap" +::= { gstTrapPrefix 20627 } + +gstCtrl3ChDELTAPowerFactorCACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDELTAPowerFactorCA, ctrl3ChDELTAName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor CA Clear Trap" +::= { gstTrapPrefix 20628 } + +gstDoorSensorStatusCLEAR NOTIFICATION-TYPE +OBJECTS { doorSensorStatus, doorSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Door sensor Clear Trap" +::= { gstTrapPrefix 20705 } + +gstWaterSensorDampnessCLEAR NOTIFICATION-TYPE +OBJECTS { waterSensorDampness, waterSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Water sensor Clear Trap" +::= { gstTrapPrefix 20805 } + +gstCurrentMonitorDeciAmpsCLEAR NOTIFICATION-TYPE +OBJECTS { currentMonitorDeciAmps, currentMonitorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 20905 } + +gstMillivoltMonitorMVCLEAR NOTIFICATION-TYPE +OBJECTS { millivoltMonitorMV, millivoltMonitorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Millivolt Monitor Clear Trap" +::= { gstTrapPrefix 21005 } + +gstPow3ChkWattHrsACLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChkWattHrsA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours A Clear Trap" +::= { gstTrapPrefix 21105 } + +gstPow3ChVoltsACLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChVoltsA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts A Clear Trap" +::= { gstTrapPrefix 21106 } + +gstPow3ChVoltMaxACLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChVoltMaxA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Max A Clear Trap" +::= { gstTrapPrefix 21107 } + +gstPow3ChVoltMinACLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChVoltMinA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Min A Clear Trap" +::= { gstTrapPrefix 21108 } + +gstPow3ChVoltPeakACLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChVoltPeakA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volt Peak A Clear Trap" +::= { gstTrapPrefix 21109 } + +gstPow3ChDeciAmpsACLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChDeciAmpsA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps A Clear Trap" +::= { gstTrapPrefix 21110 } + +gstPow3ChRealPowerACLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChRealPowerA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power A Clear Trap" +::= { gstTrapPrefix 21111 } + +gstPow3ChApparentPowerACLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChApparentPowerA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power A Clear Trap" +::= { gstTrapPrefix 21112 } + +gstPow3ChPowerFactorACLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChPowerFactorA, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor A Clear Trap" +::= { gstTrapPrefix 21113 } + +gstPow3ChkWattHrsBCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChkWattHrsB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours B Clear Trap" +::= { gstTrapPrefix 21114 } + +gstPow3ChVoltsBCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChVoltsB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts B Clear Trap" +::= { gstTrapPrefix 21115 } + +gstPow3ChVoltMaxBCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChVoltMaxB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Max B Clear Trap" +::= { gstTrapPrefix 21116 } + +gstPow3ChVoltMinBCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChVoltMinB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Min B Clear Trap" +::= { gstTrapPrefix 21117 } + +gstPow3ChVoltPeakBCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChVoltPeakB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volt Peak B Clear Trap" +::= { gstTrapPrefix 21118 } + +gstPow3ChDeciAmpsBCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChDeciAmpsB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps B Clear Trap" +::= { gstTrapPrefix 21119 } + +gstPow3ChRealPowerBCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChRealPowerB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power B Clear Trap" +::= { gstTrapPrefix 21120 } + +gstPow3ChApparentPowerBCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChApparentPowerB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power B Clear Trap" +::= { gstTrapPrefix 21121 } + +gstPow3ChPowerFactorBCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChPowerFactorB, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor B Clear Trap" +::= { gstTrapPrefix 21122 } + +gstPow3ChkWattHrsCCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChkWattHrsC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours C Clear Trap" +::= { gstTrapPrefix 21123 } + +gstPow3ChVoltsCCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChVoltsC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts C Clear Trap" +::= { gstTrapPrefix 21124 } + +gstPow3ChVoltMaxCCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChVoltMaxC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Max C Clear Trap" +::= { gstTrapPrefix 21125 } + +gstPow3ChVoltMinCCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChVoltMinC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Min C Clear Trap" +::= { gstTrapPrefix 21126 } + +gstPow3ChVoltPeakCCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChVoltPeakC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volt Peak C Clear Trap" +::= { gstTrapPrefix 21127 } + +gstPow3ChDeciAmpsCCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChDeciAmpsC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps C Clear Trap" +::= { gstTrapPrefix 21128 } + +gstPow3ChRealPowerCCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChRealPowerC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power C Clear Trap" +::= { gstTrapPrefix 21129 } + +gstPow3ChApparentPowerCCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChApparentPowerC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power C Clear Trap" +::= { gstTrapPrefix 21130 } + +gstPow3ChPowerFactorCCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChPowerFactorC, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor C Clear Trap" +::= { gstTrapPrefix 21131 } + +gstPow3ChkWattHrsTotalCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChkWattHrsTotal, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours Total Clear Trap" +::= { gstTrapPrefix 21132 } + +gstPow3ChRealPowerTotalCLEAR NOTIFICATION-TYPE +OBJECTS { pow3ChRealPowerTotal, pow3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power Total Clear Trap" +::= { gstTrapPrefix 21133 } + +gstOutlet1StatusCLEAR NOTIFICATION-TYPE +OBJECTS { outlet1Status, outletName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Outlet 1 Status Clear Trap" +::= { gstTrapPrefix 21205 } + +gstOutlet2StatusCLEAR NOTIFICATION-TYPE +OBJECTS { outlet2Status, outletName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Outlet 2 Status Clear Trap" +::= { gstTrapPrefix 21206 } + +gstVsfcSetPointCCLEAR NOTIFICATION-TYPE +OBJECTS { vsfcSetPointC, vsfcName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc Temp Set Point Sensor Clear" +::= { gstTrapPrefix 21305 } + +gstVsfcSetPointFCLEAR NOTIFICATION-TYPE +OBJECTS { vsfcSetPointF, vsfcName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc Temp Set Point Sensor Clear" +::= { gstTrapPrefix 21306 } + +gstVsfcFanSpeedCLEAR NOTIFICATION-TYPE +OBJECTS { vsfcFanSpeed, vsfcName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc Fan Speed Sensor Clear" +::= { gstTrapPrefix 21307 } + +gstVsfcIntTempCCLEAR NOTIFICATION-TYPE +OBJECTS { vsfcIntTempC, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc Internal Temp Sensor Clear" +::= { gstTrapPrefix 21308 } + +gstVsfcIntTempFCLEAR NOTIFICATION-TYPE +OBJECTS { vsfcIntTempF, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc Internal Temp Sensor Clear" +::= { gstTrapPrefix 21309 } + +gstVsfcExt1TempCCLEAR NOTIFICATION-TYPE +OBJECTS { vsfcExt1TempC, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc External Temp 1 Sensor Clear" +::= { gstTrapPrefix 21310 } + +gstVsfcExt1TempFCLEAR NOTIFICATION-TYPE +OBJECTS { vsfcExt1TempF, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc External Temp 1 Sensor Clear" +::= { gstTrapPrefix 21311 } + +gstVsfcExt2TempCCLEAR NOTIFICATION-TYPE +OBJECTS { vsfcExt2TempC, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc External Temp 2 Sensor Clear" +::= { gstTrapPrefix 21312 } + +gstVsfcExt2TempFCLEAR NOTIFICATION-TYPE +OBJECTS { vsfcExt2TempF, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc External Temp 1 Sensor Clear" +::= { gstTrapPrefix 21313 } + +gstVsfcExt3TempCCLEAR NOTIFICATION-TYPE +OBJECTS { vsfcExt3TempC, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc External Temp 3 Sensor Clear" +::= { gstTrapPrefix 21314 } + +gstVsfcExt3TempFCLEAR NOTIFICATION-TYPE +OBJECTS { vsfcExt3TempF, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc External Temp 1 Sensor Clear" +::= { gstTrapPrefix 21315 } + +gstVsfcExt4TempCCLEAR NOTIFICATION-TYPE +OBJECTS { vsfcExt4TempC, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc External Temp 4 Sensor Clear" +::= { gstTrapPrefix 21316 } + +gstVsfcExt4TempFCLEAR NOTIFICATION-TYPE +OBJECTS { vsfcExt4TempF, vsfcName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Vsfc External Temp 1 Sensor Clear" +::= { gstTrapPrefix 21317 } + +gstCtrl3ChVoltsACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChVoltsA, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts A Clear Trap" +::= { gstTrapPrefix 21405 } + +gstCtrl3ChVoltPeakACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChVoltPeakA, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak A Clear Trap" +::= { gstTrapPrefix 21406 } + +gstCtrl3ChDeciAmpsACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDeciAmpsA, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps A Clear Trap" +::= { gstTrapPrefix 21407 } + +gstCtrl3ChDeciAmpsPeakACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDeciAmpsPeakA, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak A Clear Trap" +::= { gstTrapPrefix 21408 } + +gstCtrl3ChRealPowerACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChRealPowerA, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power A Clear Trap" +::= { gstTrapPrefix 21409 } + +gstCtrl3ChApparentPowerACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChApparentPowerA, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power A Clear Trap" +::= { gstTrapPrefix 21410 } + +gstCtrl3ChPowerFactorACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChPowerFactorA, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor A Clear Trap" +::= { gstTrapPrefix 21411 } + +gstCtrl3ChVoltsBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChVoltsB, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts B Clear Trap" +::= { gstTrapPrefix 21412 } + +gstCtrl3ChVoltPeakBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChVoltPeakB, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak B Clear Trap" +::= { gstTrapPrefix 21413 } + +gstCtrl3ChDeciAmpsBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDeciAmpsB, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps B Clear Trap" +::= { gstTrapPrefix 21414 } + +gstCtrl3ChDeciAmpsPeakBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDeciAmpsPeakB, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak B Clear Trap" +::= { gstTrapPrefix 21415 } + +gstCtrl3ChRealPowerBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChRealPowerB, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power B Clear Trap" +::= { gstTrapPrefix 21416 } + +gstCtrl3ChApparentPowerBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChApparentPowerB, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power B Clear Trap" +::= { gstTrapPrefix 21417 } + +gstCtrl3ChPowerFactorBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChPowerFactorB, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor B Clear Trap" +::= { gstTrapPrefix 21418 } + +gstCtrl3ChVoltsCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChVoltsC, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts C Clear Trap" +::= { gstTrapPrefix 21419 } + +gstCtrl3ChVoltPeakCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChVoltPeakC, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak C Clear Trap" +::= { gstTrapPrefix 21420 } + +gstCtrl3ChDeciAmpsCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDeciAmpsC, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps C Clear Trap" +::= { gstTrapPrefix 21421 } + +gstCtrl3ChDeciAmpsPeakCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChDeciAmpsPeakC, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak C Clear Trap" +::= { gstTrapPrefix 21422 } + +gstCtrl3ChRealPowerCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChRealPowerC, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power C Clear Trap" +::= { gstTrapPrefix 21423 } + +gstCtrl3ChApparentPowerCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChApparentPowerC, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power C Clear Trap" +::= { gstTrapPrefix 21424 } + +gstCtrl3ChPowerFactorCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChPowerFactorC, ctrl3ChName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor C Clear Trap" +::= { gstTrapPrefix 21425 } + +gstCtrlGrpAmpsACLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsA, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group A DeciAmps Clear Trap" +::= { gstTrapPrefix 21505 } + +gstCtrlGrpAmpsBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsB, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group B DeciAmps Clear Trap" +::= { gstTrapPrefix 21506 } + +gstCtrlGrpAmpsCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsC, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group C DeciAmps Clear Trap" +::= { gstTrapPrefix 21507 } + +gstCtrlGrpAmpsDCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsD, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group D DeciAmps Clear Trap" +::= { gstTrapPrefix 21508 } + +gstCtrlGrpAmpsECLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsE, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group E DeciAmps Clear Trap" +::= { gstTrapPrefix 21509 } + +gstCtrlGrpAmpsFCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsF, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group F DeciAmps Clear Trap" +::= { gstTrapPrefix 21510 } + +gstCtrlGrpAmpsGCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsG, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group G DeciAmps Clear Trap" +::= { gstTrapPrefix 21511 } + +gstCtrlGrpAmpsHCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsH, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group H DeciAmps Clear Trap" +::= { gstTrapPrefix 21512 } + +gstCtrlGrpAmpsAVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsAVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "AVolts Clear Trap" +::= { gstTrapPrefix 21513 } + +gstCtrlGrpAmpsBVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsBVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "BVolts Clear Trap" +::= { gstTrapPrefix 21514 } + +gstCtrlGrpAmpsCVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsCVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "CVolts Clear Trap" +::= { gstTrapPrefix 21515 } + +gstCtrlGrpAmpsDVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsDVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DVolts Clear Trap" +::= { gstTrapPrefix 21516 } + +gstCtrlGrpAmpsEVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsEVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "EVolts Clear Trap" +::= { gstTrapPrefix 21517 } + +gstCtrlGrpAmpsFVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsFVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "FVolts Clear Trap" +::= { gstTrapPrefix 21518 } + +gstCtrlGrpAmpsGVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsGVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "GVolts Clear Trap" +::= { gstTrapPrefix 21519 } + +gstCtrlGrpAmpsHVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsHVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "HVolts Clear Trap" +::= { gstTrapPrefix 21520 } + +gstCtrlGrpAmpsICLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsI, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group I DeciAmps Clear Trap" +::= { gstTrapPrefix 21521 } + +gstCtrlGrpAmpsJCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsJ, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group J DeciAmps Clear Trap" +::= { gstTrapPrefix 21522 } + +gstCtrlGrpAmpsKCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsK, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group K DeciAmps Clear Trap" +::= { gstTrapPrefix 21523 } + +gstCtrlGrpAmpsLCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsL, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group L DeciAmps Clear Trap" +::= { gstTrapPrefix 21524 } + +gstCtrlGrpAmpsMCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsM, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group M DeciAmps Clear Trap" +::= { gstTrapPrefix 21525 } + +gstCtrlGrpAmpsNCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsN, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group N DeciAmps Clear Trap" +::= { gstTrapPrefix 21526 } + +gstCtrlGrpAmpsOCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsO, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group O DeciAmps Clear Trap" +::= { gstTrapPrefix 21527 } + +gstCtrlGrpAmpsPCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsP, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group P DeciAmps Clear Trap" +::= { gstTrapPrefix 21528 } + +gstCtrlGrpAmpsIVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsIVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "IVolts Clear Trap" +::= { gstTrapPrefix 21529 } + +gstCtrlGrpAmpsJVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsJVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "JVolts Clear Trap" +::= { gstTrapPrefix 21530 } + +gstCtrlGrpAmpsKVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsKVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "KVolts Clear Trap" +::= { gstTrapPrefix 21531 } + +gstCtrlGrpAmpsLVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsLVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "LVolts Clear Trap" +::= { gstTrapPrefix 21532 } + +gstCtrlGrpAmpsMVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsMVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "MVolts Clear Trap" +::= { gstTrapPrefix 21533 } + +gstCtrlGrpAmpsNVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsNVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "NVolts Clear Trap" +::= { gstTrapPrefix 21534 } + +gstCtrlGrpAmpsOVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsOVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "OVolts Clear Trap" +::= { gstTrapPrefix 21535 } + +gstCtrlGrpAmpsPVoltsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlGrpAmpsPVolts, ctrlGrpAmpsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "PVolts Clear Trap" +::= { gstTrapPrefix 21536 } + +gstCtrlOutletPendingCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlOutletPending, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Pending Clear Trap" +::= { gstTrapPrefix 21605 } + +gstCtrlOutletDeciAmpsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlOutletDeciAmps, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Outlet DeciAmps Clear Trap" +::= { gstTrapPrefix 21606 } + +gstCtrlOutletGroupCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlOutletGroup, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Group Clear Trap" +::= { gstTrapPrefix 21607 } + +gstCtrlOutletUpDelayCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlOutletUpDelay, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "UpDelay Clear Trap" +::= { gstTrapPrefix 21608 } + +gstCtrlOutletDwnDelayCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlOutletDwnDelay, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DwnDelay Clear Trap" +::= { gstTrapPrefix 21609 } + +gstCtrlOutletRbtDurationCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlOutletRbtDuration, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "RbtDuration Clear Trap" +::= { gstTrapPrefix 21610 } + +gstCtrlOutletURLCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlOutletURL, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "URL Clear Trap" +::= { gstTrapPrefix 21611 } + +gstCtrlOutletPOAActionCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlOutletPOAAction, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "POAAction Clear Trap" +::= { gstTrapPrefix 21612 } + +gstCtrlOutletPOADelayCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlOutletPOADelay, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "POADelay Clear Trap" +::= { gstTrapPrefix 21613 } + +gstCtrlOutletkWattHrsCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlOutletkWattHrs, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "kWattHrs Clear Trap" +::= { gstTrapPrefix 21614 } + +gstCtrlOutletPowerCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlOutletPower, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Clear Trap" +::= { gstTrapPrefix 21615 } + +gstCtrlOutletRbtDelayCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlOutletRbtDelay, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "RbtDelay Clear Trap" +::= { gstTrapPrefix 21616 } + +gstCtrlOutletStatusTimeCLEAR NOTIFICATION-TYPE +OBJECTS { ctrlOutletStatusTime, ctrlOutletStatus, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "StatusTime Clear Trap" +::= { gstTrapPrefix 21617 } + +gstDewPointSensorTempCCLEAR NOTIFICATION-TYPE +OBJECTS { dewPointSensorTempC, dewPointSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Dew Point Sensor - Temperature Clear Trap" +::= { gstTrapPrefix 21705 } + +gstDewPointSensorTempFCLEAR NOTIFICATION-TYPE +OBJECTS { dewPointSensorTempF, dewPointSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Dew Point Sensor - Temperature Clear Trap" +::= { gstTrapPrefix 21706 } + +gstDewPointSensorHumidityCLEAR NOTIFICATION-TYPE +OBJECTS { dewPointSensorHumidity, dewPointSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Dew Point Sensor - Humidity Clear Trap" +::= { gstTrapPrefix 21707 } + +gstDewPointSensorDewPointCCLEAR NOTIFICATION-TYPE +OBJECTS { dewPointSensorDewPointC, dewPointSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Dew Point Sensor - Dew Point Clear Trap" +::= { gstTrapPrefix 21708 } + +gstDewPointSensorDewPointFCLEAR NOTIFICATION-TYPE +OBJECTS { dewPointSensorDewPointF, dewPointSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Remote Dew Point Sensor - Dew Point Clear Trap" +::= { gstTrapPrefix 21709 } + +gstDigitalSensorDigitalCLEAR NOTIFICATION-TYPE +OBJECTS { digitalSensorDigital, digitalSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Digital sensor Clear Trap" +::= { gstTrapPrefix 21805 } + +gstDstsVoltsACLEAR NOTIFICATION-TYPE +OBJECTS { dstsVoltsA, dstsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "RMS Voltage of Side A Set Point Sensor Clear" +::= { gstTrapPrefix 21905 } + +gstDstsDeciAmpsACLEAR NOTIFICATION-TYPE +OBJECTS { dstsDeciAmpsA, dstsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "RMS Current of Side A Set Point Sensor Clear" +::= { gstTrapPrefix 21906 } + +gstDstsVoltsBCLEAR NOTIFICATION-TYPE +OBJECTS { dstsVoltsB, dstsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "RMS Voltage of Side B Set Point Sensor Clear" +::= { gstTrapPrefix 21907 } + +gstDstsDeciAmpsBCLEAR NOTIFICATION-TYPE +OBJECTS { dstsDeciAmpsB, dstsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "RMS Current of Side B Set Point Sensor Clear" +::= { gstTrapPrefix 21908 } + +gstDstsSourceAActiveCLEAR NOTIFICATION-TYPE +OBJECTS { dstsSourceAActive, dstsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Source A Active Set Point Sensor Clear" +::= { gstTrapPrefix 21909 } + +gstDstsSourceBActiveCLEAR NOTIFICATION-TYPE +OBJECTS { dstsSourceBActive, dstsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Source B Active Set Point Sensor Clear" +::= { gstTrapPrefix 21910 } + +gstDstsPowerStatusACLEAR NOTIFICATION-TYPE +OBJECTS { dstsPowerStatusA, dstsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Source A Power Qualilty Active Set Point Sensor Clear" +::= { gstTrapPrefix 21911 } + +gstDstsPowerStatusBCLEAR NOTIFICATION-TYPE +OBJECTS { dstsPowerStatusB, dstsName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Source B Power Qualilty Active Set Point Sensor Clear" +::= { gstTrapPrefix 21912 } + +gstDstsSourceATempCCLEAR NOTIFICATION-TYPE +OBJECTS { dstsSourceATempC, dstsName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Source A Temp Sensor Clear" +::= { gstTrapPrefix 21913 } + +gstDstsSourceBTempCCLEAR NOTIFICATION-TYPE +OBJECTS { dstsSourceBTempC, dstsName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Source B Temp Sensor Clear" +::= { gstTrapPrefix 21914 } + +gstCpmSensorStatusCLEAR NOTIFICATION-TYPE +OBJECTS { cpmSensorStatus, cpmSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "City Power sensor Clear Trap" +::= { gstTrapPrefix 22005 } + +gstSmokeAlarmStatusCLEAR NOTIFICATION-TYPE +OBJECTS { smokeAlarmStatus, smokeAlarmName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Smoke alarm Clear Trap" +::= { gstTrapPrefix 22105 } + +gstNeg48VdcSensorVoltageCLEAR NOTIFICATION-TYPE +OBJECTS { neg48VdcSensorVoltage, neg48VdcSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "-48Vdc Sensor Clear Trap" +::= { gstTrapPrefix 22205 } + +gstPos30VdcSensorVoltageCLEAR NOTIFICATION-TYPE +OBJECTS { pos30VdcSensorVoltage, pos30VdcSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "30Vdc Sensor Clear Trap" +::= { gstTrapPrefix 22305 } + +gstAnalogSensorAnalogCLEAR NOTIFICATION-TYPE +OBJECTS { analogSensorAnalog, analogSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Analog Sensor Clear Trap" +::= { gstTrapPrefix 22405 } + +gstCtrl3ChIECkWattHrsACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECkWattHrsA, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours A Clear Trap" +::= { gstTrapPrefix 22505 } + +gstCtrl3ChIECVoltsACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECVoltsA, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts A Clear Trap" +::= { gstTrapPrefix 22506 } + +gstCtrl3ChIECVoltPeakACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECVoltPeakA, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak A Clear Trap" +::= { gstTrapPrefix 22507 } + +gstCtrl3ChIECDeciAmpsACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECDeciAmpsA, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps A Clear Trap" +::= { gstTrapPrefix 22508 } + +gstCtrl3ChIECDeciAmpsPeakACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECDeciAmpsPeakA, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak A Clear Trap" +::= { gstTrapPrefix 22509 } + +gstCtrl3ChIECRealPowerACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECRealPowerA, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power A Clear Trap" +::= { gstTrapPrefix 22510 } + +gstCtrl3ChIECApparentPowerACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECApparentPowerA, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power A Clear Trap" +::= { gstTrapPrefix 22511 } + +gstCtrl3ChIECPowerFactorACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECPowerFactorA, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor A Clear Trap" +::= { gstTrapPrefix 22512 } + +gstCtrl3ChIECkWattHrsBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECkWattHrsB, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours B Clear Trap" +::= { gstTrapPrefix 22513 } + +gstCtrl3ChIECVoltsBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECVoltsB, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts B Clear Trap" +::= { gstTrapPrefix 22514 } + +gstCtrl3ChIECVoltPeakBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECVoltPeakB, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak B Clear Trap" +::= { gstTrapPrefix 22515 } + +gstCtrl3ChIECDeciAmpsBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECDeciAmpsB, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps B Clear Trap" +::= { gstTrapPrefix 22516 } + +gstCtrl3ChIECDeciAmpsPeakBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECDeciAmpsPeakB, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak B Clear Trap" +::= { gstTrapPrefix 22517 } + +gstCtrl3ChIECRealPowerBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECRealPowerB, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power B Clear Trap" +::= { gstTrapPrefix 22518 } + +gstCtrl3ChIECApparentPowerBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECApparentPowerB, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power B Clear Trap" +::= { gstTrapPrefix 22519 } + +gstCtrl3ChIECPowerFactorBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECPowerFactorB, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor B Clear Trap" +::= { gstTrapPrefix 22520 } + +gstCtrl3ChIECkWattHrsCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECkWattHrsC, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours C Clear Trap" +::= { gstTrapPrefix 22521 } + +gstCtrl3ChIECVoltsCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECVoltsC, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts C Clear Trap" +::= { gstTrapPrefix 22522 } + +gstCtrl3ChIECVoltPeakCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECVoltPeakC, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak C Clear Trap" +::= { gstTrapPrefix 22523 } + +gstCtrl3ChIECDeciAmpsCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECDeciAmpsC, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps C Clear Trap" +::= { gstTrapPrefix 22524 } + +gstCtrl3ChIECDeciAmpsPeakCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECDeciAmpsPeakC, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak C Clear Trap" +::= { gstTrapPrefix 22525 } + +gstCtrl3ChIECRealPowerCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECRealPowerC, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power C Clear Trap" +::= { gstTrapPrefix 22526 } + +gstCtrl3ChIECApparentPowerCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECApparentPowerC, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power C Clear Trap" +::= { gstTrapPrefix 22527 } + +gstCtrl3ChIECPowerFactorCCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECPowerFactorC, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor C Clear Trap" +::= { gstTrapPrefix 22528 } + +gstCtrl3ChIECkWattHrsTotalCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECkWattHrsTotal, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours Total Clear Trap" +::= { gstTrapPrefix 22529 } + +gstCtrl3ChIECRealPowerTotalCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl3ChIECRealPowerTotal, ctrl3ChIECName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Watts Total Clear Trap" +::= { gstTrapPrefix 22530 } + +gstClimateRelayTempCCLEAR NOTIFICATION-TYPE +OBJECTS { climateRelayTempC, climateRelayName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay Temperature Sensor Clear Trap" +::= { gstTrapPrefix 22605 } + +gstClimateRelayTempFCLEAR NOTIFICATION-TYPE +OBJECTS { climateRelayTempF, climateRelayName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay Temperature Sensor Clear Trap" +::= { gstTrapPrefix 22606 } + +gstClimateRelayIO1CLEAR NOTIFICATION-TYPE +OBJECTS { climateRelayIO1, climateRelayName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO1 Sensor Clear Trap" +::= { gstTrapPrefix 22607 } + +gstClimateRelayIO2CLEAR NOTIFICATION-TYPE +OBJECTS { climateRelayIO2, climateRelayName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO2 Sensor Clear Trap" +::= { gstTrapPrefix 22608 } + +gstClimateRelayIO3CLEAR NOTIFICATION-TYPE +OBJECTS { climateRelayIO3, climateRelayName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO3 Sensor Clear Trap" +::= { gstTrapPrefix 22609 } + +gstClimateRelayIO4CLEAR NOTIFICATION-TYPE +OBJECTS { climateRelayIO4, climateRelayName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO4 Sensor Clear Trap" +::= { gstTrapPrefix 22610 } + +gstClimateRelayIO5CLEAR NOTIFICATION-TYPE +OBJECTS { climateRelayIO5, climateRelayName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO5 Sensor Clear Trap" +::= { gstTrapPrefix 22611 } + +gstClimateRelayIO6CLEAR NOTIFICATION-TYPE +OBJECTS { climateRelayIO6, climateRelayName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO6 Sensor Clear Trap" +::= { gstTrapPrefix 22612 } + +gstAirSpeedSwitchSensorAirSpeedCLEAR NOTIFICATION-TYPE +OBJECTS { airSpeedSwitchSensorAirSpeed, airSpeedSwitchSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Air Speed Switch Clear Trap" +::= { gstTrapPrefix 22805 } + +gstPowerDMDeciAmps1CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps1, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139153 } + +gstPowerDMDeciAmps2CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps2, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139154 } + +gstPowerDMDeciAmps3CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps3, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139155 } + +gstPowerDMDeciAmps4CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps4, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139156 } + +gstPowerDMDeciAmps5CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps5, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139157 } + +gstPowerDMDeciAmps6CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps6, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139158 } + +gstPowerDMDeciAmps7CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps7, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139159 } + +gstPowerDMDeciAmps8CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps8, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139160 } + +gstPowerDMDeciAmps9CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps9, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139161 } + +gstPowerDMDeciAmps10CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps10, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139162 } + +gstPowerDMDeciAmps11CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps11, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139163 } + +gstPowerDMDeciAmps12CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps12, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139164 } + +gstPowerDMDeciAmps13CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps13, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139165 } + +gstPowerDMDeciAmps14CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps14, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139166 } + +gstPowerDMDeciAmps15CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps15, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139167 } + +gstPowerDMDeciAmps16CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps16, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139168 } + +gstPowerDMDeciAmps17CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps17, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139169 } + +gstPowerDMDeciAmps18CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps18, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139170 } + +gstPowerDMDeciAmps19CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps19, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139171 } + +gstPowerDMDeciAmps20CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps20, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139172 } + +gstPowerDMDeciAmps21CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps21, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139173 } + +gstPowerDMDeciAmps22CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps22, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139174 } + +gstPowerDMDeciAmps23CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps23, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139175 } + +gstPowerDMDeciAmps24CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps24, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139176 } + +gstPowerDMDeciAmps25CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps25, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139177 } + +gstPowerDMDeciAmps26CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps26, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139178 } + +gstPowerDMDeciAmps27CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps27, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139179 } + +gstPowerDMDeciAmps28CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps28, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139180 } + +gstPowerDMDeciAmps29CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps29, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139181 } + +gstPowerDMDeciAmps30CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps30, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139182 } + +gstPowerDMDeciAmps31CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps31, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139183 } + +gstPowerDMDeciAmps32CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps32, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139184 } + +gstPowerDMDeciAmps33CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps33, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139185 } + +gstPowerDMDeciAmps34CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps34, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139186 } + +gstPowerDMDeciAmps35CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps35, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139187 } + +gstPowerDMDeciAmps36CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps36, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139188 } + +gstPowerDMDeciAmps37CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps37, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139189 } + +gstPowerDMDeciAmps38CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps38, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139190 } + +gstPowerDMDeciAmps39CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps39, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139191 } + +gstPowerDMDeciAmps40CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps40, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139192 } + +gstPowerDMDeciAmps41CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps41, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139193 } + +gstPowerDMDeciAmps42CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps42, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139194 } + +gstPowerDMDeciAmps43CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps43, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139195 } + +gstPowerDMDeciAmps44CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps44, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139196 } + +gstPowerDMDeciAmps45CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps45, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139197 } + +gstPowerDMDeciAmps46CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps46, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139198 } + +gstPowerDMDeciAmps47CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps47, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139199 } + +gstPowerDMDeciAmps48CLEAR NOTIFICATION-TYPE +OBJECTS { powerDMDeciAmps48, powerDMName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "DM48 Current Monitor Amps Clear Trap" +::= { gstTrapPrefix 139200 } + +gstIoExpanderIO1CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO1, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO1 Sensor Clear Trap" +::= { gstTrapPrefix 23037 } + +gstIoExpanderIO2CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO2, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO2 Sensor Clear Trap" +::= { gstTrapPrefix 23038 } + +gstIoExpanderIO3CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO3, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO3 Sensor Clear Trap" +::= { gstTrapPrefix 23039 } + +gstIoExpanderIO4CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO4, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO4 Sensor Clear Trap" +::= { gstTrapPrefix 23040 } + +gstIoExpanderIO5CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO5, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO5 Sensor Clear Trap" +::= { gstTrapPrefix 23041 } + +gstIoExpanderIO6CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO6, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO6 Sensor Clear Trap" +::= { gstTrapPrefix 23042 } + +gstIoExpanderIO7CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO7, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO7 Sensor Clear Trap" +::= { gstTrapPrefix 23043 } + +gstIoExpanderIO8CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO8, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO8 Sensor Clear Trap" +::= { gstTrapPrefix 23044 } + +gstIoExpanderIO9CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO9, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO9 Sensor Clear Trap" +::= { gstTrapPrefix 23045 } + +gstIoExpanderIO10CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO10, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO10 Sensor Clear Trap" +::= { gstTrapPrefix 23046 } + +gstIoExpanderIO11CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO11, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO11 Sensor Clear Trap" +::= { gstTrapPrefix 23047 } + +gstIoExpanderIO12CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO12, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO12 Sensor Clear Trap" +::= { gstTrapPrefix 23048 } + +gstIoExpanderIO13CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO13, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO13 Sensor Clear Trap" +::= { gstTrapPrefix 23049 } + +gstIoExpanderIO14CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO14, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO14 Sensor Clear Trap" +::= { gstTrapPrefix 23050 } + +gstIoExpanderIO15CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO15, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO15 Sensor Clear Trap" +::= { gstTrapPrefix 23051 } + +gstIoExpanderIO16CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO16, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO16 Sensor Clear Trap" +::= { gstTrapPrefix 23052 } + +gstIoExpanderIO17CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO17, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO17 Sensor Clear Trap" +::= { gstTrapPrefix 23053 } + +gstIoExpanderIO18CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO18, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO18 Sensor Clear Trap" +::= { gstTrapPrefix 23054 } + +gstIoExpanderIO19CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO19, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO19 Sensor Clear Trap" +::= { gstTrapPrefix 23055 } + +gstIoExpanderIO20CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO20, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO20 Sensor Clear Trap" +::= { gstTrapPrefix 23056 } + +gstIoExpanderIO21CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO21, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO21 Sensor Clear Trap" +::= { gstTrapPrefix 23057 } + +gstIoExpanderIO22CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO22, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO22 Sensor Clear Trap" +::= { gstTrapPrefix 23058 } + +gstIoExpanderIO23CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO23, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO23 Sensor Clear Trap" +::= { gstTrapPrefix 23059 } + +gstIoExpanderIO24CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO24, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO24 Sensor Clear Trap" +::= { gstTrapPrefix 23060 } + +gstIoExpanderIO25CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO25, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO25 Sensor Clear Trap" +::= { gstTrapPrefix 23061 } + +gstIoExpanderIO26CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO26, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO26 Sensor Clear Trap" +::= { gstTrapPrefix 23062 } + +gstIoExpanderIO27CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO27, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO27 Sensor Clear Trap" +::= { gstTrapPrefix 23063 } + +gstIoExpanderIO28CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO28, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO28 Sensor Clear Trap" +::= { gstTrapPrefix 23064 } + +gstIoExpanderIO29CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO29, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO29 Sensor Clear Trap" +::= { gstTrapPrefix 23065 } + +gstIoExpanderIO30CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO30, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO30 Sensor Clear Trap" +::= { gstTrapPrefix 23066 } + +gstIoExpanderIO31CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO31, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO31 Sensor Clear Trap" +::= { gstTrapPrefix 23067 } + +gstIoExpanderIO32CLEAR NOTIFICATION-TYPE +OBJECTS { ioExpanderIO32, ioExpanderName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Climate Relay IO32 Sensor Clear Trap" +::= { gstTrapPrefix 23068 } + +gstT3hdSensorIntTempCCLEAR NOTIFICATION-TYPE +OBJECTS { t3hdSensorIntTempC, t3hdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - Internal Temperature C Clear Trap" +::= { gstTrapPrefix 23106 } + +gstT3hdSensorIntTempFCLEAR NOTIFICATION-TYPE +OBJECTS { t3hdSensorIntTempF, t3hdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - Internal Temperature F Clear Trap" +::= { gstTrapPrefix 23107 } + +gstT3hdSensorIntHumidityCLEAR NOTIFICATION-TYPE +OBJECTS { t3hdSensorIntHumidity, t3hdSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - Internal Humidity Clear Trap" +::= { gstTrapPrefix 23108 } + +gstT3hdSensorIntDewPointCCLEAR NOTIFICATION-TYPE +OBJECTS { t3hdSensorIntDewPointC, t3hdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - Internal Dew Point C Clear Trap" +::= { gstTrapPrefix 23109 } + +gstT3hdSensorIntDewPointFCLEAR NOTIFICATION-TYPE +OBJECTS { t3hdSensorIntDewPointF, t3hdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - Internal Dew Point F Clear Trap" +::= { gstTrapPrefix 23110 } + +gstT3hdSensorExt1TempCCLEAR NOTIFICATION-TYPE +OBJECTS { t3hdSensorExt1TempC, t3hdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - External 1 Temperature C Clear Trap" +::= { gstTrapPrefix 23113 } + +gstT3hdSensorExt1TempFCLEAR NOTIFICATION-TYPE +OBJECTS { t3hdSensorExt1TempF, t3hdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - External 1 Temperature F Clear Trap" +::= { gstTrapPrefix 23114 } + +gstT3hdSensorExt2TempCCLEAR NOTIFICATION-TYPE +OBJECTS { t3hdSensorExt2TempC, t3hdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - External 2 Temperature C Clear Trap" +::= { gstTrapPrefix 23117 } + +gstT3hdSensorExt2TempFCLEAR NOTIFICATION-TYPE +OBJECTS { t3hdSensorExt2TempF, t3hdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "T3HD - External 2 Temperature F Clear Trap" +::= { gstTrapPrefix 23118 } + +gstThdSensorTempCCLEAR NOTIFICATION-TYPE +OBJECTS { thdSensorTempC, thdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "THD - Temperature C Clear Trap" +::= { gstTrapPrefix 23205 } + +gstThdSensorTempFCLEAR NOTIFICATION-TYPE +OBJECTS { thdSensorTempF, thdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "THD - Temperature F Clear Trap" +::= { gstTrapPrefix 23206 } + +gstThdSensorHumidityCLEAR NOTIFICATION-TYPE +OBJECTS { thdSensorHumidity, thdSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "THD - Humidity Clear Trap" +::= { gstTrapPrefix 23207 } + +gstThdSensorDewPointCCLEAR NOTIFICATION-TYPE +OBJECTS { thdSensorDewPointC, thdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "THD - Dew Point C Clear Trap" +::= { gstTrapPrefix 23208 } + +gstThdSensorDewPointFCLEAR NOTIFICATION-TYPE +OBJECTS { thdSensorDewPointF, thdSensorName, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "THD - Dew Point F Clear Trap" +::= { gstTrapPrefix 23209 } + +gstPos60VdcSensorVoltageCLEAR NOTIFICATION-TYPE +OBJECTS { pos60VdcSensorVoltage, pos60VdcSensorName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "60Vdc Sensor Clear Trap" +::= { gstTrapPrefix 23305 } + +gstCtrl2CirTotkWattHrsTotCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotkWattHrsTot, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours Total Clear Trap" +::= { gstTrapPrefix 23405 } + +gstCtrl2CirTotVoltsTotCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotVoltsTot, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Total Clear Trap" +::= { gstTrapPrefix 23406 } + +gstCtrl2CirTotVoltPeakTotCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotVoltPeakTot, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak Total Clear Trap" +::= { gstTrapPrefix 23407 } + +gstCtrl2CirTotDeciAmpsTotCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotDeciAmpsTot, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Total Clear Trap" +::= { gstTrapPrefix 23408 } + +gstCtrl2CirTotDeciAmpsPeakTotCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotDeciAmpsPeakTot, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak Total Clear Trap" +::= { gstTrapPrefix 23409 } + +gstCtrl2CirTotRealPowerTotCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotRealPowerTot, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power Total Clear Trap" +::= { gstTrapPrefix 23410 } + +gstCtrl2CirTotApparentPowerTotCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotApparentPowerTot, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power Total Clear Trap" +::= { gstTrapPrefix 23411 } + +gstCtrl2CirTotPowerFactorTotCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotPowerFactorTot, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor Total Clear Trap" +::= { gstTrapPrefix 23412 } + +gstCtrl2CirTotkWattHrsACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotkWattHrsA, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours A Clear Trap" +::= { gstTrapPrefix 23413 } + +gstCtrl2CirTotVoltsACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotVoltsA, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts A Clear Trap" +::= { gstTrapPrefix 23414 } + +gstCtrl2CirTotVoltPeakACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotVoltPeakA, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak A Clear Trap" +::= { gstTrapPrefix 23415 } + +gstCtrl2CirTotDeciAmpsACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotDeciAmpsA, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps A Clear Trap" +::= { gstTrapPrefix 23416 } + +gstCtrl2CirTotDeciAmpsPeakACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotDeciAmpsPeakA, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak A Clear Trap" +::= { gstTrapPrefix 23417 } + +gstCtrl2CirTotRealPowerACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotRealPowerA, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power A Clear Trap" +::= { gstTrapPrefix 23418 } + +gstCtrl2CirTotApparentPowerACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotApparentPowerA, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power A Clear Trap" +::= { gstTrapPrefix 23419 } + +gstCtrl2CirTotPowerFactorACLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotPowerFactorA, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor A Clear Trap" +::= { gstTrapPrefix 23420 } + +gstCtrl2CirTotkWattHrsBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotkWattHrsB, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Kilo Watt Hours B Clear Trap" +::= { gstTrapPrefix 23421 } + +gstCtrl2CirTotVoltsBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotVoltsB, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts B Clear Trap" +::= { gstTrapPrefix 23422 } + +gstCtrl2CirTotVoltPeakBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotVoltPeakB, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Volts Peak B Clear Trap" +::= { gstTrapPrefix 23423 } + +gstCtrl2CirTotDeciAmpsBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotDeciAmpsB, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps B Clear Trap" +::= { gstTrapPrefix 23424 } + +gstCtrl2CirTotDeciAmpsPeakBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotDeciAmpsPeakB, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Deciamps Peak B Clear Trap" +::= { gstTrapPrefix 23425 } + +gstCtrl2CirTotRealPowerBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotRealPowerB, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Real Power B Clear Trap" +::= { gstTrapPrefix 23426 } + +gstCtrl2CirTotApparentPowerBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotApparentPowerB, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Apparent Power B Clear Trap" +::= { gstTrapPrefix 23427 } + +gstCtrl2CirTotPowerFactorBCLEAR NOTIFICATION-TYPE +OBJECTS { ctrl2CirTotPowerFactorB, ctrl2CirTotName, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "Power Factor B Clear Trap" +::= { gstTrapPrefix 23428 } + +gstSc10ControlModeCLEAR NOTIFICATION-TYPE +OBJECTS { sc10ControlMode, sc10Name, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "SC10 Control Mode Sensor Clear" +::= { gstTrapPrefix 23505 } + +gstSc10SetpointCCLEAR NOTIFICATION-TYPE +OBJECTS { sc10SetpointC, sc10Name, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "SC10 Temp Set Point Sensor Clear" +::= { gstTrapPrefix 23506 } + +gstSc10SetpointFCLEAR NOTIFICATION-TYPE +OBJECTS { sc10SetpointF, sc10Name, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "SC10 Temp Set Point Sensor Clear" +::= { gstTrapPrefix 23507 } + +gstSc10TempCCLEAR NOTIFICATION-TYPE +OBJECTS { sc10TempC, sc10Name, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "SC10 Internal Temp Sensor Clear" +::= { gstTrapPrefix 23508 } + +gstSc10TempFCLEAR NOTIFICATION-TYPE +OBJECTS { sc10TempF, sc10Name, productFriendlyName, alarmTripType, temperaturePrecision, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "SC10 Internal Temp Sensor Clear" +::= { gstTrapPrefix 23509 } + +gstSc10CapacityCLEAR NOTIFICATION-TYPE +OBJECTS { sc10Capacity, sc10Name, productFriendlyName, alarmTripType, alarmTrigger, alarmInstance } +STATUS current +DESCRIPTION "SC10 Fan Speed Sensor Clear" +::= { gstTrapPrefix 23510 } + +END + diff --git a/mibs/geist/GEIST-V4-MIB b/mibs/geist/GEIST-V4-MIB new file mode 100644 index 0000000000..4083970b33 --- /dev/null +++ b/mibs/geist/GEIST-V4-MIB @@ -0,0 +1,1404 @@ + +GEIST-V4-MIB DEFINITIONS ::= BEGIN + +IMPORTS + +DisplayString FROM SNMPv2-TC +MODULE-IDENTITY, OBJECT-TYPE, IpAddress, enterprises, Integer32, Gauge32, NOTIFICATION-TYPE FROM SNMPv2-SMI; + +geist MODULE-IDENTITY + LAST-UPDATED "201209110000Z" + ORGANIZATION "Geist" + CONTACT-INFO "support@geistglobal.com" + DESCRIPTION "The MIB for Geist Products" + REVISION "201209110000Z" + DESCRIPTION "Original version" + ::= { enterprises 21239 } + +blackbird OBJECT IDENTIFIER + ::= { geist 5 } +watchdog100 OBJECT IDENTIFIER + ::= { blackbird 1 } + +--###########################################################################################-- +--deviceInfo-- +--###########################################################################################-- + +deviceInfo OBJECT IDENTIFIER + ::= { watchdog100 1 } + +productTitle OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Product name" + ::= { deviceInfo 1 } + +productVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Product version" + ::= { deviceInfo 2 } + +productFriendlyName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "User-assigned name" + ::= { deviceInfo 3 } + +productMacAddress OBJECT-TYPE + SYNTAX OCTET STRING + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Product's unique MAC address" + ::= { deviceInfo 4 } + +productUrl OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Product's main URL access point" + ::= { deviceInfo 5 } + +deviceCount OBJECT-TYPE + SYNTAX Integer32(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Total number of devices on unit" + ::= { deviceInfo 6 } + +temperatureUnits OBJECT-TYPE + SYNTAX Integer32(0..1) + MAX-ACCESS read-write + STATUS current + DESCRIPTION "Current units for temperature values. 0 = Degrees Fahrenheit, 1 = Degrees Celsius" + ::= { deviceInfo 7 } + +--###########################################################################################-- +--internalTable-- +--###########################################################################################-- + +internalTable OBJECT-TYPE + SYNTAX SEQUENCE OF InternalEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Internal sensors for units" + ::= { watchdog100 2 } + +internalEntry OBJECT-TYPE + SYNTAX InternalEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Entry in the internalTable table: each entry contains an index and other sensor details" + INDEX { internalIndex } + ::= { internalTable 1 } + +InternalEntry ::= SEQUENCE { + internalIndex Integer32, + internalSerial DisplayString, + internalName DisplayString, + internalAvail Gauge32, + internalTemp Integer32, + internalHumidity Integer32, + internalDewPoint Integer32 +} + +internalIndex OBJECT-TYPE + SYNTAX Integer32(1..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Table entry index value" + ::= { internalEntry 1 } + +internalSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { internalEntry 2 } + +internalName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { internalEntry 3 } + +internalAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable" + ::= { internalEntry 4 } + +internalTemp OBJECT-TYPE + SYNTAX Integer32(-40..200) + UNITS "0.1 Degrees" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo" + ::= { internalEntry 5 } + +internalHumidity OBJECT-TYPE + SYNTAX Integer32(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Humidity reading" + ::= { internalEntry 6 } + +internalDewPoint OBJECT-TYPE + SYNTAX Integer32(-40..200) + UNITS "0.1 Degrees" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Dew-point in tenths of degrees. Units are given by temperatureUnits field in deviceInfo" + ::= { internalEntry 7 } + +--###########################################################################################-- +--tempSensorTable-- +--###########################################################################################-- + +tempSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF TempSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Remote Temperature Sensor" + ::= { watchdog100 4 } + +tempSensorEntry OBJECT-TYPE + SYNTAX TempSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Entry in the tempSensorTable table: each entry contains an index and other sensor details" + INDEX { tempSensorIndex } + ::= { tempSensorTable 1 } + +TempSensorEntry ::= SEQUENCE { + tempSensorIndex Integer32, + tempSensorSerial DisplayString, + tempSensorName DisplayString, + tempSensorAvail Gauge32, + tempSensorTemp Integer32 +} + +tempSensorIndex OBJECT-TYPE + SYNTAX Integer32(1..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Table entry index value" + ::= { tempSensorEntry 1 } + +tempSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { tempSensorEntry 2 } + +tempSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { tempSensorEntry 3 } + +tempSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable" + ::= { tempSensorEntry 4 } + +tempSensorTemp OBJECT-TYPE + SYNTAX Integer32(-40..200) + UNITS "0.1 Degrees" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo" + ::= { tempSensorEntry 5 } + +--###########################################################################################-- +--airFlowSensorTable-- +--###########################################################################################-- + +airFlowSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF AirFlowSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Remote Airflow, Humidity, Temperature and Dewpoint Sensor " + ::= { watchdog100 5 } + +airFlowSensorEntry OBJECT-TYPE + SYNTAX AirFlowSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Entry in the airFlowSensorTable table: each entry contains an index and other sensor details" + INDEX { airFlowSensorIndex } + ::= { airFlowSensorTable 1 } + +AirFlowSensorEntry ::= SEQUENCE { + airFlowSensorIndex Integer32, + airFlowSensorSerial DisplayString, + airFlowSensorName DisplayString, + airFlowSensorAvail Gauge32, + airFlowSensorTemp Integer32, + airFlowSensorFlow Integer32, + airFlowSensorHumidity Integer32, + airFlowSensorDewPoint Integer32 +} + +airFlowSensorIndex OBJECT-TYPE + SYNTAX Integer32(1..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Table entry index value" + ::= { airFlowSensorEntry 1 } + +airFlowSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { airFlowSensorEntry 2 } + +airFlowSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { airFlowSensorEntry 3 } + +airFlowSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable" + ::= { airFlowSensorEntry 4 } + +airFlowSensorTemp OBJECT-TYPE + SYNTAX Integer32(-40..200) + UNITS "0.1 Degrees" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo" + ::= { airFlowSensorEntry 5 } + +airFlowSensorFlow OBJECT-TYPE + SYNTAX Integer32(0..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "AFHT3 Airflow reading" + ::= { airFlowSensorEntry 6 } + +airFlowSensorHumidity OBJECT-TYPE + SYNTAX Integer32(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "AFHT3 Humidity reading" + ::= { airFlowSensorEntry 7 } + +airFlowSensorDewPoint OBJECT-TYPE + SYNTAX Integer32(-40..200) + UNITS "0.1 Degrees" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Dew Point in tenths of degrees. Units are given by temperatureUnits field in deviceInfo" + ::= { airFlowSensorEntry 8 } + +--###########################################################################################-- +--dewPointSensorTable-- +--###########################################################################################-- + +dewPointSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF DewPointSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Remote Dew Point sensor" + ::= { watchdog100 6 } + +dewPointSensorEntry OBJECT-TYPE + SYNTAX DewPointSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Entry in the dewPointSensorTable table: each entry contains an index and other sensor details" + INDEX { dewPointSensorIndex } + ::= { dewPointSensorTable 1 } + +DewPointSensorEntry ::= SEQUENCE { + dewPointSensorIndex Integer32, + dewPointSensorSerial DisplayString, + dewPointSensorName DisplayString, + dewPointSensorAvail Gauge32, + dewPointSensorTemp Integer32, + dewPointSensorHumidity Integer32, + dewPointSensorDewPoint Integer32 +} + +dewPointSensorIndex OBJECT-TYPE + SYNTAX Integer32(1..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Table entry index value" + ::= { dewPointSensorEntry 1 } + +dewPointSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { dewPointSensorEntry 2 } + +dewPointSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { dewPointSensorEntry 3 } + +dewPointSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable" + ::= { dewPointSensorEntry 4 } + +dewPointSensorTemp OBJECT-TYPE + SYNTAX Integer32(-40..200) + UNITS "0.1 Degrees" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInfo" + ::= { dewPointSensorEntry 5 } + +dewPointSensorHumidity OBJECT-TYPE + SYNTAX Integer32(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Humidity reading" + ::= { dewPointSensorEntry 6 } + +dewPointSensorDewPoint OBJECT-TYPE + SYNTAX Integer32(-40..200) + UNITS "0.1 Degrees" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Dew-point in tenths of degrees. Units are given by temperatureUnits field in deviceInfo" + ::= { dewPointSensorEntry 7 } + +--###########################################################################################-- +--ccatSensorTable-- +--###########################################################################################-- + +ccatSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF CcatSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Remote CCAT sensor" + ::= { watchdog100 7 } + +ccatSensorEntry OBJECT-TYPE + SYNTAX CcatSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Entry in the ccatSensorTable table: each entry contains an index and other sensor details" + INDEX { ccatSensorIndex } + ::= { ccatSensorTable 1 } + +CcatSensorEntry ::= SEQUENCE { + ccatSensorIndex Integer32, + ccatSensorSerial DisplayString, + ccatSensorName DisplayString, + ccatSensorAvail Gauge32, + ccatSensorValue Integer32, + ccatSensorType DisplayString, + ccatSensorDescription DisplayString +} + +ccatSensorIndex OBJECT-TYPE + SYNTAX Integer32(1..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Table entry index value" + ::= { ccatSensorEntry 1 } + +ccatSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { ccatSensorEntry 2 } + +ccatSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { ccatSensorEntry 3 } + +ccatSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable" + ::= { ccatSensorEntry 4 } + +ccatSensorValue OBJECT-TYPE + SYNTAX Integer32(-100..5000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "CCAT sensor reading" + ::= { ccatSensorEntry 5 } + +ccatSensorType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "CCAT sensor type" + ::= { ccatSensorEntry 6 } + +ccatSensorDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "CCAT sensor value description" + ::= { ccatSensorEntry 7 } + +--###########################################################################################-- +--t3hdSensorTable-- +--###########################################################################################-- + +t3hdSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF T3hdSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Remote Temperature x 3, Humidity and Dewpoint Sensor" + ::= { watchdog100 8 } + +t3hdSensorEntry OBJECT-TYPE + SYNTAX T3hdSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Entry in the t3hdSensorTable table: each entry contains an index and other sensor details" + INDEX { t3hdSensorIndex } + ::= { t3hdSensorTable 1 } + +T3hdSensorEntry ::= SEQUENCE { + t3hdSensorIndex Integer32, + t3hdSensorSerial DisplayString, + t3hdSensorName DisplayString, + t3hdSensorAvail Gauge32, + t3hdSensorIntName DisplayString, + t3hdSensorIntTemp Integer32, + t3hdSensorIntHumidity Integer32, + t3hdSensorIntDewPoint Integer32, + t3hdSensorExtAAvail Gauge32, + t3hdSensorExtAName DisplayString, + t3hdSensorExtATemp Integer32, + t3hdSensorExtBAvail Gauge32, + t3hdSensorExtBName DisplayString, + t3hdSensorExtBTemp Integer32 +} + +t3hdSensorIndex OBJECT-TYPE + SYNTAX Integer32(1..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Table entry index value" + ::= { t3hdSensorEntry 1 } + +t3hdSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { t3hdSensorEntry 2 } + +t3hdSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { t3hdSensorEntry 3 } + +t3hdSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable" + ::= { t3hdSensorEntry 4 } + +t3hdSensorIntName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "T3HD Sensor Internal Friendly Name" + ::= { t3hdSensorEntry 5 } + +t3hdSensorIntTemp OBJECT-TYPE + SYNTAX Integer32(-40..200) + UNITS "0.1 Degrees" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Internal Temperature in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo" + ::= { t3hdSensorEntry 6 } + +t3hdSensorIntHumidity OBJECT-TYPE + SYNTAX Integer32(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "T3HD Sensor Internal Humidity" + ::= { t3hdSensorEntry 7 } + +t3hdSensorIntDewPoint OBJECT-TYPE + SYNTAX Integer32(-40..200) + UNITS "0.1 Degrees" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Internal DewPoint in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo" + ::= { t3hdSensorEntry 8 } + +t3hdSensorExtAAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "T3HD External A status: 0 = Unavailable, 1 = Available" + ::= { t3hdSensorEntry 9 } + +t3hdSensorExtAName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "T3HD External A Friendly Name" + ::= { t3hdSensorEntry 10 } + +t3hdSensorExtATemp OBJECT-TYPE + SYNTAX Integer32(-40..200) + UNITS "0.1 Degrees" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for External Temperature A in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo" + ::= { t3hdSensorEntry 11 } + +t3hdSensorExtBAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "T3HD External B status: 0 = Unavailable, 1 = Available" + ::= { t3hdSensorEntry 12 } + +t3hdSensorExtBName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "T3HD External B Friendly Name" + ::= { t3hdSensorEntry 13 } + +t3hdSensorExtBTemp OBJECT-TYPE + SYNTAX Integer32(-40..200) + UNITS "0.1 Degrees" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for External Temperature B in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo" + ::= { t3hdSensorEntry 14 } + +--###########################################################################################-- +--thdSensorTable-- +--###########################################################################################-- + +thdSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF ThdSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Remote Temperature, Humidity and Dewpoint Sensor" + ::= { watchdog100 9 } + +thdSensorEntry OBJECT-TYPE + SYNTAX ThdSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Entry in the thdSensorTable table: each entry contains an index and other sensor details" + INDEX { thdSensorIndex } + ::= { thdSensorTable 1 } + +ThdSensorEntry ::= SEQUENCE { + thdSensorIndex Integer32, + thdSensorSerial DisplayString, + thdSensorName DisplayString, + thdSensorAvail Gauge32, + thdSensorTemp Integer32, + thdSensorHumidity Integer32, + thdSensorDewPoint Integer32 +} + +thdSensorIndex OBJECT-TYPE + SYNTAX Integer32(1..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Table entry index value" + ::= { thdSensorEntry 1 } + +thdSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { thdSensorEntry 2 } + +thdSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { thdSensorEntry 3 } + +thdSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable" + ::= { thdSensorEntry 4 } + +thdSensorTemp OBJECT-TYPE + SYNTAX Integer32(-40..200) + UNITS "0.1 Degrees" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for Temperature in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo" + ::= { thdSensorEntry 5 } + +thdSensorHumidity OBJECT-TYPE + SYNTAX Integer32(0..100) + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "THD Sensor Humidity" + ::= { thdSensorEntry 6 } + +thdSensorDewPoint OBJECT-TYPE + SYNTAX Integer32(-40..200) + UNITS "0.1 Degrees" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current reading for DewPoint in 0.1 degrees. Units are given by temperatureUnits field in deviceInfo" + ::= { thdSensorEntry 7 } + +--###########################################################################################-- +--rpmSensorTable-- +--###########################################################################################-- + +rpmSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF RpmSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Remote Power Manager Sensor" + ::= { watchdog100 10 } + +rpmSensorEntry OBJECT-TYPE + SYNTAX RpmSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Entry in the rpmSensorTable table: each entry contains an index and other sensor details" + INDEX { rpmSensorIndex } + ::= { rpmSensorTable 1 } + +RpmSensorEntry ::= SEQUENCE { + rpmSensorIndex Integer32, + rpmSensorSerial DisplayString, + rpmSensorName DisplayString, + rpmSensorAvail Gauge32, + rpmSensorEnergy Gauge32, + rpmSensorVoltage Gauge32, + rpmSensorVoltageMax Gauge32, + rpmSensorVoltageMin Gauge32, + rpmSensorVoltagePeak Gauge32, + rpmSensorCurrent Gauge32, + rpmSensorRealPower Gauge32, + rpmSensorApparentPower Gauge32, + rpmSensorPowerFactor Gauge32, + rpmSensorOutlet1 Gauge32, + rpmSensorOutlet2 Gauge32 +} + +rpmSensorIndex OBJECT-TYPE + SYNTAX Integer32(1..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Table entry index value" + ::= { rpmSensorEntry 1 } + +rpmSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { rpmSensorEntry 2 } + +rpmSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { rpmSensorEntry 3 } + +rpmSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable" + ::= { rpmSensorEntry 4 } + +rpmSensorEnergy OBJECT-TYPE + SYNTAX Gauge32 + UNITS "kWh" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RPM Sensor Accumulated Energy" + ::= { rpmSensorEntry 5 } + +rpmSensorVoltage OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RPM Sensor Voltage" + ::= { rpmSensorEntry 6 } + +rpmSensorVoltageMax OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RPM Sensor Voltage (Max)" + ::= { rpmSensorEntry 7 } + +rpmSensorVoltageMin OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RPM Sensor Voltage (Min)" + ::= { rpmSensorEntry 8 } + +rpmSensorVoltagePeak OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RPM Sensor Voltage (Peak)" + ::= { rpmSensorEntry 9 } + +rpmSensorCurrent OBJECT-TYPE + SYNTAX Gauge32 + UNITS "0.1 Amps (rms)" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RPM Sensor Current reading in deciAmps" + ::= { rpmSensorEntry 10 } + +rpmSensorRealPower OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Watts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RPM Sensor Real Power" + ::= { rpmSensorEntry 11 } + +rpmSensorApparentPower OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volt-Amps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RPM Sensor Apparent Power" + ::= { rpmSensorEntry 12 } + +rpmSensorPowerFactor OBJECT-TYPE + SYNTAX Gauge32 + UNITS "%" + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RPM Sensor Power Factor" + ::= { rpmSensorEntry 13 } + +rpmSensorOutlet1 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RPM Sensor Outlet 1 State: 0 = off, 1 = on" + ::= { rpmSensorEntry 14 } + +rpmSensorOutlet2 OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "RPM Sensor Outlet 2 State: 0 = off, 1 = on" + ::= { rpmSensorEntry 15 } + +--###########################################################################################-- +--a2dSensorTable-- +--###########################################################################################-- + +a2dSensorTable OBJECT-TYPE + SYNTAX SEQUENCE OF A2DSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Analog Measurement Sensor (Voltage, Current, or Dry Contact)" + ::= { watchdog100 11 } + +a2DSensorEntry OBJECT-TYPE + SYNTAX A2DSensorEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION "Entry in the a2dSensorTable table: each entry contains an index and other sensor details" + INDEX { a2dSensorIndex } + ::= { a2dSensorTable 1 } + +A2DSensorEntry ::= SEQUENCE { + a2dSensorIndex Integer32, + a2dSensorSerial DisplayString, + a2dSensorName DisplayString, + a2dSensorAvail Gauge32, + a2dSensorValue Integer32 +} + +a2dSensorIndex OBJECT-TYPE + SYNTAX Integer32(1..100) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Table entry index value" + ::= { a2DSensorEntry 1 } + +a2dSensorSerial OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Serial Number" + ::= { a2DSensorEntry 2 } + +a2dSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Friendly Name" + ::= { a2DSensorEntry 3 } + +a2dSensorAvail OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable" + ::= { a2DSensorEntry 4 } + +a2dSensorValue OBJECT-TYPE + SYNTAX Integer32(-1000000..1000000) + MAX-ACCESS read-only + STATUS current + DESCRIPTION "Current analog measurement reading within either a user defined or preset range depending on device mode." + ::= { a2DSensorEntry 5 } + +--###########################################################################################-- +--Notifications-- +--###########################################################################################-- + +trap OBJECT IDENTIFIER ::= { watchdog100 32767 } +trapPrefix OBJECT IDENTIFIER ::= { trap 0 } + +internalTestNOTIFY NOTIFICATION-TYPE + STATUS current + DESCRIPTION "Test SNMP Trap" + ::= { trapPrefix 10101 } + +--#####deviceInfo#####-- + +--#####internalTable#####-- + +internalAvailNOTIFY NOTIFICATION-TYPE + OBJECTS { internalAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap" + ::= { trapPrefix 10204 } + +internalAvailCLEAR NOTIFICATION-TYPE + OBJECTS { internalAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap" + ::= { trapPrefix 20204 } + +internalTempNOTIFY NOTIFICATION-TYPE + OBJECTS { internalTemp, temperatureUnits } + STATUS current + DESCRIPTION "Internal Temperature Sensor Trap" + ::= { trapPrefix 10205 } + +internalTempCLEAR NOTIFICATION-TYPE + OBJECTS { internalTemp, temperatureUnits } + STATUS current + DESCRIPTION "Internal Temperature Sensor Clear Trap" + ::= { trapPrefix 20205 } + +internalHumidityNOTIFY NOTIFICATION-TYPE + OBJECTS { internalHumidity } + STATUS current + DESCRIPTION "Humidity reading Trap" + ::= { trapPrefix 10206 } + +internalHumidityCLEAR NOTIFICATION-TYPE + OBJECTS { internalHumidity } + STATUS current + DESCRIPTION "Humidity reading Clear Trap" + ::= { trapPrefix 20206 } + +internalDewPointNOTIFY NOTIFICATION-TYPE + OBJECTS { internalDewPoint, temperatureUnits } + STATUS current + DESCRIPTION "Internal Dew Point Sensor Trap" + ::= { trapPrefix 10207 } + +internalDewPointCLEAR NOTIFICATION-TYPE + OBJECTS { internalDewPoint, temperatureUnits } + STATUS current + DESCRIPTION "Internal Dew Point Sensor Clear Trap" + ::= { trapPrefix 20207 } + +--#####tempSensorTable#####-- + +tempSensorAvailNOTIFY NOTIFICATION-TYPE + OBJECTS { tempSensorAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap" + ::= { trapPrefix 10404 } + +tempSensorAvailCLEAR NOTIFICATION-TYPE + OBJECTS { tempSensorAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap" + ::= { trapPrefix 20404 } + +tempSensorTempNOTIFY NOTIFICATION-TYPE + OBJECTS { tempSensorTemp, temperatureUnits } + STATUS current + DESCRIPTION "Remote Temperature Sensor Trap" + ::= { trapPrefix 10405 } + +tempSensorTempCLEAR NOTIFICATION-TYPE + OBJECTS { tempSensorTemp, temperatureUnits } + STATUS current + DESCRIPTION "Remote Temperature Sensor Clear Trap" + ::= { trapPrefix 20405 } + +--#####airFlowSensorTable#####-- + +airFlowSensorAvailNOTIFY NOTIFICATION-TYPE + OBJECTS { airFlowSensorAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap" + ::= { trapPrefix 10504 } + +airFlowSensorAvailCLEAR NOTIFICATION-TYPE + OBJECTS { airFlowSensorAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap" + ::= { trapPrefix 20504 } + +airFlowSensorTempNOTIFY NOTIFICATION-TYPE + OBJECTS { airFlowSensorTemp, temperatureUnits } + STATUS current + DESCRIPTION "AFHT3 Sensor Temperature Trap" + ::= { trapPrefix 10505 } + +airFlowSensorTempCLEAR NOTIFICATION-TYPE + OBJECTS { airFlowSensorTemp, temperatureUnits } + STATUS current + DESCRIPTION "AFHT3 Sensor Temperature Clear Trap" + ::= { trapPrefix 20505 } + +airFlowSensorFlowNOTIFY NOTIFICATION-TYPE + OBJECTS { airFlowSensorFlow } + STATUS current + DESCRIPTION "AFHT3 Airflow reading Trap" + ::= { trapPrefix 10506 } + +airFlowSensorFlowCLEAR NOTIFICATION-TYPE + OBJECTS { airFlowSensorFlow } + STATUS current + DESCRIPTION "AFHT3 Airflow reading Clear Trap" + ::= { trapPrefix 20506 } + +airFlowSensorHumidityNOTIFY NOTIFICATION-TYPE + OBJECTS { airFlowSensorHumidity } + STATUS current + DESCRIPTION "AFHT3 Humidity reading Trap" + ::= { trapPrefix 10507 } + +airFlowSensorHumidityCLEAR NOTIFICATION-TYPE + OBJECTS { airFlowSensorHumidity } + STATUS current + DESCRIPTION "AFHT3 Humidity reading Clear Trap" + ::= { trapPrefix 20507 } + +airFlowSensorDewPointNOTIFY NOTIFICATION-TYPE + OBJECTS { airFlowSensorDewPoint, temperatureUnits } + STATUS current + DESCRIPTION "AFHT3 Sensor Dew Point Trap" + ::= { trapPrefix 10508 } + +airFlowSensorDewPointCLEAR NOTIFICATION-TYPE + OBJECTS { airFlowSensorDewPoint, temperatureUnits } + STATUS current + DESCRIPTION "AFHT3 Sensor Dew Point Clear Trap" + ::= { trapPrefix 20508 } + +--#####dewPointSensorTable#####-- + +dewPointSensorAvailNOTIFY NOTIFICATION-TYPE + OBJECTS { dewPointSensorAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap" + ::= { trapPrefix 10604 } + +dewPointSensorAvailCLEAR NOTIFICATION-TYPE + OBJECTS { dewPointSensorAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap" + ::= { trapPrefix 20604 } + +dewPointSensorTempNOTIFY NOTIFICATION-TYPE + OBJECTS { dewPointSensorTemp, temperatureUnits } + STATUS current + DESCRIPTION "Remote Dew Point Sensor Temperature Trap" + ::= { trapPrefix 10605 } + +dewPointSensorTempCLEAR NOTIFICATION-TYPE + OBJECTS { dewPointSensorTemp, temperatureUnits } + STATUS current + DESCRIPTION "Remote Dew Point Sensor Temperature Clear Trap" + ::= { trapPrefix 20605 } + +dewPointSensorHumidityNOTIFY NOTIFICATION-TYPE + OBJECTS { dewPointSensorHumidity } + STATUS current + DESCRIPTION "Humidity reading Trap" + ::= { trapPrefix 10606 } + +dewPointSensorHumidityCLEAR NOTIFICATION-TYPE + OBJECTS { dewPointSensorHumidity } + STATUS current + DESCRIPTION "Humidity reading Clear Trap" + ::= { trapPrefix 20606 } + +dewPointSensorDewPointNOTIFY NOTIFICATION-TYPE + OBJECTS { dewPointSensorDewPoint, temperatureUnits } + STATUS current + DESCRIPTION "Remote Dew Point Sensor Dew Point Trap" + ::= { trapPrefix 10607 } + +dewPointSensorDewPointCLEAR NOTIFICATION-TYPE + OBJECTS { dewPointSensorDewPoint, temperatureUnits } + STATUS current + DESCRIPTION "Remote Dew Point Sensor Dew Point Clear Trap" + ::= { trapPrefix 20607 } + +--#####ccatSensorTable#####-- + +ccatSensorAvailNOTIFY NOTIFICATION-TYPE + OBJECTS { ccatSensorAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap" + ::= { trapPrefix 10704 } + +ccatSensorAvailCLEAR NOTIFICATION-TYPE + OBJECTS { ccatSensorAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap" + ::= { trapPrefix 20704 } + +ccatSensorValueNOTIFY NOTIFICATION-TYPE + OBJECTS { ccatSensorValue, ccatSensorType } + STATUS current + DESCRIPTION "CCAT sensor reading Trap" + ::= { trapPrefix 10705 } + +ccatSensorValueCLEAR NOTIFICATION-TYPE + OBJECTS { ccatSensorValue, ccatSensorType } + STATUS current + DESCRIPTION "CCAT sensor reading Clear Trap" + ::= { trapPrefix 20705 } + +--#####t3hdSensorTable#####-- + +t3hdSensorAvailNOTIFY NOTIFICATION-TYPE + OBJECTS { t3hdSensorAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap" + ::= { trapPrefix 10804 } + +t3hdSensorAvailCLEAR NOTIFICATION-TYPE + OBJECTS { t3hdSensorAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap" + ::= { trapPrefix 20804 } + +t3hdSensorIntTempNOTIFY NOTIFICATION-TYPE + OBJECTS { t3hdSensorIntTemp, temperatureUnits } + STATUS current + DESCRIPTION "T3HD Sensor Temperature Trap" + ::= { trapPrefix 10806 } + +t3hdSensorIntTempCLEAR NOTIFICATION-TYPE + OBJECTS { t3hdSensorIntTemp, temperatureUnits } + STATUS current + DESCRIPTION "T3HD Sensor Temperature Clear Trap" + ::= { trapPrefix 20806 } + +t3hdSensorIntHumidityNOTIFY NOTIFICATION-TYPE + OBJECTS { t3hdSensorIntHumidity } + STATUS current + DESCRIPTION "T3HD Sensor Internal Humidity Trap" + ::= { trapPrefix 10807 } + +t3hdSensorIntHumidityCLEAR NOTIFICATION-TYPE + OBJECTS { t3hdSensorIntHumidity } + STATUS current + DESCRIPTION "T3HD Sensor Internal Humidity Clear Trap" + ::= { trapPrefix 20807 } + +t3hdSensorIntDewPointNOTIFY NOTIFICATION-TYPE + OBJECTS { t3hdSensorIntDewPoint, temperatureUnits } + STATUS current + DESCRIPTION "T3HD Sensor Dew Point Trap" + ::= { trapPrefix 10808 } + +t3hdSensorIntDewPointCLEAR NOTIFICATION-TYPE + OBJECTS { t3hdSensorIntDewPoint, temperatureUnits } + STATUS current + DESCRIPTION "T3HD Sensor Dew Point Clear Trap" + ::= { trapPrefix 20808 } + +t3hdSensorExtATempNOTIFY NOTIFICATION-TYPE + OBJECTS { t3hdSensorExtATemp, temperatureUnits } + STATUS current + DESCRIPTION "T3HD Sensor External A Temperature Trap" + ::= { trapPrefix 10811 } + +t3hdSensorExtATempCLEAR NOTIFICATION-TYPE + OBJECTS { t3hdSensorExtATemp, temperatureUnits } + STATUS current + DESCRIPTION "T3HD Sensor External A Temperature Clear Trap" + ::= { trapPrefix 20811 } + +t3hdSensorExtBTempNOTIFY NOTIFICATION-TYPE + OBJECTS { t3hdSensorExtBTemp, temperatureUnits } + STATUS current + DESCRIPTION "T3HD Sensor External B Temperature Trap" + ::= { trapPrefix 10814 } + +t3hdSensorExtBTempCLEAR NOTIFICATION-TYPE + OBJECTS { t3hdSensorExtBTemp, temperatureUnits } + STATUS current + DESCRIPTION "T3HD Sensor External B Temperature Clear Trap" + ::= { trapPrefix 20814 } + +--#####thdSensorTable#####-- + +thdSensorAvailNOTIFY NOTIFICATION-TYPE + OBJECTS { thdSensorAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap" + ::= { trapPrefix 10904 } + +thdSensorAvailCLEAR NOTIFICATION-TYPE + OBJECTS { thdSensorAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap" + ::= { trapPrefix 20904 } + +thdSensorTempNOTIFY NOTIFICATION-TYPE + OBJECTS { thdSensorTemp, temperatureUnits } + STATUS current + DESCRIPTION "THD Sensor Temperature Trap" + ::= { trapPrefix 10905 } + +thdSensorTempCLEAR NOTIFICATION-TYPE + OBJECTS { thdSensorTemp, temperatureUnits } + STATUS current + DESCRIPTION "THD Sensor Temperature Clear Trap" + ::= { trapPrefix 20905 } + +thdSensorHumidityNOTIFY NOTIFICATION-TYPE + OBJECTS { thdSensorHumidity } + STATUS current + DESCRIPTION "THD Sensor Humidity Trap" + ::= { trapPrefix 10906 } + +thdSensorHumidityCLEAR NOTIFICATION-TYPE + OBJECTS { thdSensorHumidity } + STATUS current + DESCRIPTION "THD Sensor Humidity Clear Trap" + ::= { trapPrefix 20906 } + +thdSensorDewPointNOTIFY NOTIFICATION-TYPE + OBJECTS { thdSensorDewPoint, temperatureUnits } + STATUS current + DESCRIPTION "THD Sensor Dew Point Trap" + ::= { trapPrefix 10907 } + +thdSensorDewPointCLEAR NOTIFICATION-TYPE + OBJECTS { thdSensorDewPoint, temperatureUnits } + STATUS current + DESCRIPTION "THD Sensor Dew Point Clear Trap" + ::= { trapPrefix 20907 } + +--#####rpmSensorTable#####-- + +rpmSensorAvailNOTIFY NOTIFICATION-TYPE + OBJECTS { rpmSensorAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap" + ::= { trapPrefix 11004 } + +rpmSensorAvailCLEAR NOTIFICATION-TYPE + OBJECTS { rpmSensorAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap" + ::= { trapPrefix 21004 } + +rpmSensorEnergyNOTIFY NOTIFICATION-TYPE + OBJECTS { rpmSensorEnergy } + STATUS current + DESCRIPTION "RPM Sensor Accumulated Energy Trap" + ::= { trapPrefix 11005 } + +rpmSensorEnergyCLEAR NOTIFICATION-TYPE + OBJECTS { rpmSensorEnergy } + STATUS current + DESCRIPTION "RPM Sensor Accumulated Energy Clear Trap" + ::= { trapPrefix 21005 } + +rpmSensorVoltageNOTIFY NOTIFICATION-TYPE + OBJECTS { rpmSensorVoltage } + STATUS current + DESCRIPTION "RPM Sensor Voltage Trap" + ::= { trapPrefix 11006 } + +rpmSensorVoltageCLEAR NOTIFICATION-TYPE + OBJECTS { rpmSensorVoltage } + STATUS current + DESCRIPTION "RPM Sensor Voltage Clear Trap" + ::= { trapPrefix 21006 } + +rpmSensorVoltageMaxNOTIFY NOTIFICATION-TYPE + OBJECTS { rpmSensorVoltageMax } + STATUS current + DESCRIPTION "RPM Sensor Voltage (Max) Trap" + ::= { trapPrefix 11007 } + +rpmSensorVoltageMaxCLEAR NOTIFICATION-TYPE + OBJECTS { rpmSensorVoltageMax } + STATUS current + DESCRIPTION "RPM Sensor Voltage (Max) Clear Trap" + ::= { trapPrefix 21007 } + +rpmSensorVoltageMinNOTIFY NOTIFICATION-TYPE + OBJECTS { rpmSensorVoltageMin } + STATUS current + DESCRIPTION "RPM Sensor Voltage (Min) Trap" + ::= { trapPrefix 11008 } + +rpmSensorVoltageMinCLEAR NOTIFICATION-TYPE + OBJECTS { rpmSensorVoltageMin } + STATUS current + DESCRIPTION "RPM Sensor Voltage (Min) Clear Trap" + ::= { trapPrefix 21008 } + +rpmSensorVoltagePeakNOTIFY NOTIFICATION-TYPE + OBJECTS { rpmSensorVoltagePeak } + STATUS current + DESCRIPTION "RPM Sensor Voltage (Peak) Trap" + ::= { trapPrefix 11009 } + +rpmSensorVoltagePeakCLEAR NOTIFICATION-TYPE + OBJECTS { rpmSensorVoltagePeak } + STATUS current + DESCRIPTION "RPM Sensor Voltage (Peak) Clear Trap" + ::= { trapPrefix 21009 } + +rpmSensorCurrentNOTIFY NOTIFICATION-TYPE + OBJECTS { rpmSensorCurrent } + STATUS current + DESCRIPTION "RPM Sensor Current Trap" + ::= { trapPrefix 11010 } + +rpmSensorCurrentCLEAR NOTIFICATION-TYPE + OBJECTS { rpmSensorCurrent } + STATUS current + DESCRIPTION "RPM Sensor Current Clear Trap" + ::= { trapPrefix 21010 } + +rpmSensorRealPowerNOTIFY NOTIFICATION-TYPE + OBJECTS { rpmSensorRealPower } + STATUS current + DESCRIPTION "RPM Sensor Real Power Trap" + ::= { trapPrefix 11011 } + +rpmSensorRealPowerCLEAR NOTIFICATION-TYPE + OBJECTS { rpmSensorRealPower } + STATUS current + DESCRIPTION "RPM Sensor Real Power Clear Trap" + ::= { trapPrefix 21011 } + +rpmSensorApparentPowerNOTIFY NOTIFICATION-TYPE + OBJECTS { rpmSensorApparentPower } + STATUS current + DESCRIPTION "RPM Sensor Apparent Power Trap" + ::= { trapPrefix 11012 } + +rpmSensorApparentPowerCLEAR NOTIFICATION-TYPE + OBJECTS { rpmSensorApparentPower } + STATUS current + DESCRIPTION "RPM Sensor Apparent Power Clear Trap" + ::= { trapPrefix 21012 } + +rpmSensorPowerFactorNOTIFY NOTIFICATION-TYPE + OBJECTS { rpmSensorPowerFactor } + STATUS current + DESCRIPTION "RPM Sensor Power Factor Trap" + ::= { trapPrefix 11013 } + +rpmSensorPowerFactorCLEAR NOTIFICATION-TYPE + OBJECTS { rpmSensorPowerFactor } + STATUS current + DESCRIPTION "RPM Sensor Power Factor Clear Trap" + ::= { trapPrefix 21013 } + +--#####a2dSensorTable#####-- + +a2dSensorAvailNOTIFY NOTIFICATION-TYPE + OBJECTS { a2dSensorAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap" + ::= { trapPrefix 11104 } + +a2dSensorAvailCLEAR NOTIFICATION-TYPE + OBJECTS { a2dSensorAvail } + STATUS current + DESCRIPTION "Device availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap" + ::= { trapPrefix 21104 } + +a2dSensorValueNOTIFY NOTIFICATION-TYPE + OBJECTS { a2dSensorValue } + STATUS current + DESCRIPTION "A2D Analog Sensor Measurement Trap" + ::= { trapPrefix 11105 } + +a2dSensorValueCLEAR NOTIFICATION-TYPE + OBJECTS { a2dSensorValue } + STATUS current + DESCRIPTION "A2D Analog Sensor Measurement Clear Trap" + ::= { trapPrefix 21105 } + +END \ No newline at end of file diff --git a/tests/OSDiscoveryTest.php b/tests/OSDiscoveryTest.php index 682cd3f194..0ba5b500d0 100644 --- a/tests/OSDiscoveryTest.php +++ b/tests/OSDiscoveryTest.php @@ -824,6 +824,11 @@ class DiscoveryTest extends \PHPUnit_Framework_TestCase $this->checkOS('gamatronicups'); } + public function testGeistWatchdog() + { + $this->checkOS('geist-watchdog'); + } + public function testGenerexUps() { $this->checkOS('generex-ups'); diff --git a/tests/snmpsim/geist-watchdog.snmprec b/tests/snmpsim/geist-watchdog.snmprec new file mode 100644 index 0000000000..b53b9c954b --- /dev/null +++ b/tests/snmpsim/geist-watchdog.snmprec @@ -0,0 +1,2 @@ +1.3.6.1.2.1.1.1.0|4|Watchdog 100 +1.3.6.1.2.1.1.2.0|6|1.3.6.1.4.1.21239.5.1 \ No newline at end of file