diff --git a/includes/definitions/discovery/vmware-esxi.yaml b/includes/definitions/discovery/vmware-esxi.yaml new file mode 100644 index 0000000000..a2b89cdd7f --- /dev/null +++ b/includes/definitions/discovery/vmware-esxi.yaml @@ -0,0 +1,7 @@ +modules: + os: + serial: ENTITY-MIB::entPhysicalSerialNum.1 + hardware: ENTITY-MIB::entPhysicalDescr.1 + version: VMWARE-SYSTEM-MIB::vmwProdVersion.0 + features: VMWARE-SYSTEM-MIB::vmwProdBuild.0 + features_template: 'build {{ VMWARE-SYSTEM-MIB::vmwProdBuild.0 }}' diff --git a/includes/definitions/discovery/vmware-vcsa.yaml b/includes/definitions/discovery/vmware-vcsa.yaml new file mode 100644 index 0000000000..116c06e1a6 --- /dev/null +++ b/includes/definitions/discovery/vmware-vcsa.yaml @@ -0,0 +1,5 @@ +modules: + os: + version: VMWARE-SYSTEM-MIB::vmwProdVersion.0 + features: VMWARE-SYSTEM-MIB::vmwProdBuild.0 + features_template: 'build {{ VMWARE-SYSTEM-MIB::vmwProdBuild.0 }}' diff --git a/includes/definitions/vmware-esxi.yaml b/includes/definitions/vmware-esxi.yaml new file mode 100644 index 0000000000..3fc2ebe45a --- /dev/null +++ b/includes/definitions/vmware-esxi.yaml @@ -0,0 +1,14 @@ +os: vmware-esxi +type: server +group: unix +text: VMware ESXi +icon: vmware +mib_dir: vmware +ifXmcbc: true +over: + - { graph: device_bits, text: 'Device Traffic' } +discovery_modules: + vmware-vminfo: true +discovery: + - + sysObjectID: .1.3.6.1.4.1.6876.4.1 diff --git a/includes/definitions/vmware.yaml b/includes/definitions/vmware-vcsa.yaml similarity index 54% rename from includes/definitions/vmware.yaml rename to includes/definitions/vmware-vcsa.yaml index f7d442b056..315e6ab248 100644 --- a/includes/definitions/vmware.yaml +++ b/includes/definitions/vmware-vcsa.yaml @@ -1,14 +1,17 @@ -os: vmware +os: vmware-vcsa +group: unix type: server -text: VMware -ifXmcbc: true +text: VMware vCenter +icon: vmware +mib_dir: vmware over: - { graph: device_bits, text: 'Device Traffic' } -discovery_modules: - vmware-vminfo: true discovery: + - + sysObjectID: + - .1.3.6.1.4.1.6876.4.7 + - .1.3.6.1.4.1.6876.4.8 - sysDescr_regex: - - '/^VMware ESX/' - '/^VMware-vCenter-Server-Appliance/' - '/^VMware vCenter Server Appliance/' diff --git a/includes/discovery/mempools/hrstorage.inc.php b/includes/discovery/mempools/hrstorage.inc.php index b7863aebaf..30d9562474 100644 --- a/includes/discovery/mempools/hrstorage.inc.php +++ b/includes/discovery/mempools/hrstorage.inc.php @@ -1,5 +1,7 @@ \S+\s){1,2}/', $device['sysDescr'], $ver); - $version = $ver[0]; - - preg_match('/(\d){7}/', $device['sysDescr'], $feat); - $features = 'build-' . $feat[0]; - - preg_match('/^(?>\S+\s*){1,4}/', $hardware_snmp, $hard); - $hardware = rtrim($hard[0]); -} else { - $version = preg_replace('/^VMware /', '', $data[0]['vmwProdName']) . ' ' . $data[0]['vmwProdVersion']; - $features = 'build-' . $data[0]['vmwProdBuild']; - $hardware = $hardware_snmp; -} - -$serial = snmp_get($device, 'entPhysicalSerialNum.1', '-OsvQU', 'ENTITY-MIB'); - -// Clean up Generic hardware descriptions -$hardware = rewrite_generic_hardware($hardware); - /* * CONSOLE: Start the VMware discovery process. */ diff --git a/includes/polling/ports.inc.php b/includes/polling/ports.inc.php index 5d60e4c4a1..2c9b6ddd55 100644 --- a/includes/polling/ports.inc.php +++ b/includes/polling/ports.inc.php @@ -1,6 +1,7 @@ )->Networking & Security->Service Composer" + REVISION "202006030001Z" + DESCRIPTION + "Addition of traps for releases 6.4.7" + REVISION "201907090001Z" + DESCRIPTION + "Addition of traps for releases 6.4.6" + REVISION "201902120001Z" + DESCRIPTION + "Addition of traps for releases 6.4.5" + REVISION "201805310001Z" + DESCRIPTION + "Addition of traps for releases 6.4.2" + REVISION "201804250001Z" + DESCRIPTION + "Addition of traps for releases 6.3.7" + REVISION "201803080000Z" + DESCRIPTION + "Addition of traps for releases 6.3.6 and 6.4.1." + REVISION "201712080000Z" + DESCRIPTION + "Addition of one new trap for capacity dashbard events." + REVISION "201711220000Z" + DESCRIPTION + "Addition of one new varbinds : vmwNsxMVxlanHostEvents. + Represents the security events received from host to NSX Manager." + REVISION "201711010000Z" + DESCRIPTION + "See VMWARE-NSX-MANAGER-AGENTCAP-MIB.mib for Versions of NSX manager which support this MIB version. + This file describes all the notifications sent from the NSX Manager appliance. Includes + Addition of three new varbinds: vmwNsxMEventSourceID, vmwNsxMEventSourceType and + vmwNsxMEventSourceIP + to vmwNsxMMessagingConfigFailed, vmwNsxMMessagingConfigFailed, vmwNsxMMessagingReconfigFailed, + vmwNsxMMessagingConfigFailedNotifSkip, vmwNsxMMessagingInfraUp, vmwNsxMMessagingInfraDown, + vmwNsxMMessagingDisabled, vmwNsxMVxlanControllerDisconnected, vmwNsxMVxlanControllerConnected, + vmwNsxMVxlanControllerVmPoweredOn. + Represents the Controller VM connected or disconnected, and Controller + VM Powered On respectively. + WARNING: This mib module will not be backward compatible with next version." + REVISION "201707050000Z" + DESCRIPTION + "Addition of two new varbinds : vmwNsxMVxlanPortgroupDeleted, vmwNsxMVxlanVDSandPgMismatch. + Represents the Vxlan Port Group Deleted and DVS, Vxlan PG Mismatch respectively." + REVISION "201707030000Z" + DESCRIPTION + "Addition of traps for capacity dashboard events." + REVISION "201706010000Z" + DESCRIPTION + "Addition of three new varbinds : vmwNsxMEventSourceID, vmwNsxMEventSourceType and vmwNsxMEventSourceIP. + Represents the event source's ID, Type and IP address respectively." REVISION "201704270000Z" DESCRIPTION "This is the 6.3.0 version of the NSX Manager MIB. @@ -85,6 +134,33 @@ VmwNsxManagerTypeSeverity ::= TEXTUAL-CONVENTION SYNTAX INTEGER { informational(1), low(2), medium(3), major(4), critical(5), high(6) } +VmwNsxManagerSourceID ::= TEXTUAL-CONVENTION + DISPLAY-HINT "256a" + STATUS current + DESCRIPTION + "The event sources' IDs for the NSX Manager system event. This data type can be used to + specify multiple event source IDs seperated by a semicolon. In NSX Manager, we can have + multiple event sources and hence multiple event source IDs." + SYNTAX OCTET STRING (SIZE (0..256)) + +VmwNsxManagerSourceType ::= TEXTUAL-CONVENTION + DISPLAY-HINT "256a" + STATUS current + DESCRIPTION + "The event sources' types for the NSX Manager system event. This data type can be used to + specify multiple event source types seperated by a semicolon. In NSX Manager, we can have + multiple event sources and hence multiple event source types." + SYNTAX OCTET STRING (SIZE (0..256)) + +VmwNsxManagerSourceIPAddress ::= TEXTUAL-CONVENTION + DISPLAY-HINT "256a" + STATUS current + DESCRIPTION + "The IP address(es) of the source(s) of the NSX Manager event. This data type can be used to + specify multiple IP addresses seperated by a semicolon. Using InetAddress and InetAddressType + from INET-ADDRESS-MIB would have been relevant in case there was a single event source. + In NSX Manager, we can have multiple event sources and hence multiple IP addresses." + SYNTAX OCTET STRING (SIZE (0..256)) -- -- Top-level MIB groups @@ -171,6 +247,30 @@ vmwNsxMCount OBJECT-TYPE last 5 minute interval." ::= { vmwNsxMAlertData 7 } +vmwNsxMEventSourceID OBJECT-TYPE + SYNTAX VmwNsxManagerSourceID + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The object ID(s) of the source(s) of the event." + ::= { vmwNsxMAlertData 8 } + +vmwNsxMEventSourceType OBJECT-TYPE + SYNTAX VmwNsxManagerSourceType + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The object type(s) of the source(s) of the event." + ::= { vmwNsxMAlertData 9 } + +vmwNsxMEventSourceIP OBJECT-TYPE + SYNTAX VmwNsxManagerSourceIPAddress + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The IP address(es) of the source(s) of the event." + ::= { vmwNsxMAlertData 10 } + -- -- Groups related traps -- @@ -229,7 +329,10 @@ vmwNsxMSnmpDisabled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -249,7 +352,10 @@ vmwNsxMSnmpManagerConfigUpdated NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -284,7 +390,10 @@ vmwNsxMIpAddedBlackList NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -303,7 +412,10 @@ vmwNsxMIpRemovedBlackList NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -320,7 +432,10 @@ vmwNsxMSsoConfigFailure NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -339,7 +454,10 @@ vmwNsxMSsoUnconfigured NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -355,7 +473,10 @@ vmwNsxMUserRoleAssigned NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -371,7 +492,10 @@ vmwNsxMUserRoleUnassigned NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -387,7 +511,10 @@ vmwNsxMGroupRoleAssigned NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -403,7 +530,10 @@ vmwNsxMGroupRoleUnassigned NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -419,7 +549,10 @@ vmwNsxMVcLoginFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -436,7 +569,10 @@ vmwNsxMVcDisconnected NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -453,7 +589,10 @@ vmwNsxMLostVcConnectivity NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -470,7 +609,10 @@ vmwNsxMSsoDisconnected NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -484,6 +626,30 @@ vmwNsxMSsoDisconnected NOTIFICATION-TYPE SSO connection state is 1 hour." ::= { vmwNsxMSecurityPrefix 12 } +vmwNsxMSsoTimeout NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "When we try to configure VC on a system where SSO is already configured, + we fetch the token to login to the VC using SSO. If it times out during + that, this trap is raised. + Action required: Try reconnecting to the SSO server and if the service remains + unresponsive, try restarting the NSX management service from the NSX appliance + management UI. Contact the SSO administrator if the issue persists. + Frequency of traps: Whenever we try to configure VC on a system where + SSO is already configured." + ::= { vmwNsxMSecurityPrefix 13 } + -- -- Distributed Firewall related traps -- @@ -508,7 +674,10 @@ vmwNsxMFltrCnfgUpdateFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -523,7 +692,10 @@ vmwNsxMFltrCnfgNotAppliedToVnic NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -538,7 +710,10 @@ vmwNsxMFltrCnfgAppliedToVnic NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -553,7 +728,10 @@ vmwNsxMFltrCreatedForVnic NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -569,7 +747,10 @@ vmwNsxMFltrDeletedForVnic NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -584,7 +765,10 @@ vmwNsxMFirewallConfigUpdateFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -601,7 +785,10 @@ vmwNsxMFirewallRuleFailedVnic NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -620,7 +807,10 @@ vmwNsxMFirewallRuleAppliedVnic NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -636,7 +826,10 @@ vmwNsxMCntnrCnfgUpdateFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -653,7 +846,10 @@ vmwNsxMFlowMissed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -671,7 +867,10 @@ vmwNsxMSpoofGuardCnfgUpdateFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -688,7 +887,10 @@ vmwNsxMSpoofGuardFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -706,7 +908,10 @@ vmwNsxMSpoofGuardApplied NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -721,7 +926,10 @@ vmwNsxMSpoofGuardDisableFail NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -737,7 +945,10 @@ vmwNsxMSpoofGuardDisabled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -752,7 +963,10 @@ vmwNsxMLegacyAppServiceDeletionFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -767,7 +981,10 @@ vmwNsxMFirewallCpuThresholdCrossed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -782,7 +999,10 @@ vmwNsxMFirewallMemThresholdCrossed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -797,7 +1017,10 @@ vmwNsxMConnPerSecThrshldCrossed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -812,7 +1035,10 @@ vmwNsxMFirewallCnfgUpdateTimedOut NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -829,7 +1055,10 @@ vmwNsxMSpoofGuardCnfgUpdateTmOut NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -846,7 +1075,10 @@ vmwNsxMFirewallPublishFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -862,7 +1094,10 @@ vmwNsxMCntnrUpdatePublishFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -878,7 +1113,10 @@ vmwNsxMSpoofGuardUpdatePublishFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -893,7 +1131,10 @@ vmwNsxMExcludeListPublishFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -908,7 +1149,10 @@ vmwNsxMFirewallCnfgUpdateOnDltCntnr NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -925,7 +1169,10 @@ vmwNsxMHostSyncFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -940,7 +1187,10 @@ vmwNsxMHostSynced NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -955,7 +1205,10 @@ vmwNsxMFirewallInstalled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -969,7 +1222,10 @@ vmwNsxMFirewallInstallFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -984,7 +1240,10 @@ vmwNsxMFirewallClusterInstalled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -998,7 +1257,10 @@ vmwNsxMFirewallClusterUninstalled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1012,7 +1274,10 @@ vmwNsxMFirewallClusterDisabled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1026,7 +1291,10 @@ vmwNsxMFirewallForceSyncClusterFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1043,7 +1311,10 @@ vmwNsxMFirewallForceSyncClusterSuccess NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1058,7 +1329,10 @@ vmwNsxMFirewallVsfwdProcessStarted NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1073,7 +1347,10 @@ vmwNsxMFirewallRulesetApplyAllFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1089,7 +1366,10 @@ vmwNsxMFirewallRulesetAppliedAll NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1104,7 +1384,10 @@ vmwNsxMCntnrCnfgApplyFailedToVnic NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1120,7 +1403,10 @@ vmwNsxMCntnrCnfgApplyAllFailedToVnic NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1136,7 +1422,10 @@ vmwNsxMCntnrCnfgAppliedAllToVnic NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1151,7 +1440,10 @@ vmwNsxMSpoofGuardApplyAllFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1169,7 +1461,10 @@ vmwNsxMSpoofGuardAppliedAll NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1184,7 +1479,10 @@ vmwNsxMFirewallTimeoutUpdateFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1199,7 +1497,10 @@ vmwNsxMFirewallTimeoutApplyFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1214,7 +1515,10 @@ vmwNsxMFirewallTimeoutApplied NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1229,7 +1533,10 @@ vmwNsxMFirewallTimeoutApplyAllFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1244,7 +1551,10 @@ vmwNsxMFirewallTimeoutAppliedAll NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1259,7 +1569,10 @@ vmwNsxMCntnrCnfgAppliedToVnic NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -1267,6 +1580,187 @@ vmwNsxMCntnrCnfgAppliedToVnic NOTIFICATION-TYPE Action required: None." ::= { vmwNsxMFirewallPrefix 49 } +vmwNsxMFirewallMaxConcurrentConnectionsThresholdCrossed NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "vsfwd maximum concurrent connections threshold was exceeded for the specified vnic. + Reduce the amount of traffic on the vnic in question." + ::= { vmwNsxMFirewallPrefix 50 } + +vmwNsxMFirewallProcessMemoryThresholdCrossed NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "vsfwd memory utilization threshold was exceeded for the specified process. + Reduce the number of rules or containers in firewall config. If persists, there may be memory leaks in the process so restarting it may be necessary." + ::= { vmwNsxMFirewallPrefix 51 } + +vmwNsxMFirewallCpuThresholdCrossCleared NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "vsfwd CPU usage is back to below threshold level. + Action required: None." + ::= { vmwNsxMFirewallPrefix 52 } + +vmwNsxMFirewallMemThresholdCrossCleared NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "vsfwd heap memory usage is back to below threshold level for the specified heap. + Action required: None." + ::= { vmwNsxMFirewallPrefix 53 } + +vmwNsxMConnPerSecThrshldCrossCleared NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "vsfwd Connectons Per Second (CPS) is back to below threshold level for the specified vnic. + Action required: None." + ::= { vmwNsxMFirewallPrefix 54 } + +vmwNsxMFirewallMaxConcurrentConnectionsThresholdCrossCleared NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "vsfwd maximum concurrent connections is back to below threshold level for the specified vnic. + Action required: None." + ::= { vmwNsxMFirewallPrefix 55 } + +vmwNsxMFirewallProcessMemoryThresholdCrossCleared NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "vsfwd memory utilization is back to below threshold level for the specified process. + Action required: None." + ::= { vmwNsxMFirewallPrefix 56 } + +vmwNsxMFirewallThresholdConfigApplied NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "Successfully applied all threshold config. + Action required: None." + ::= { vmwNsxMFirewallPrefix 57 } + +vmwNsxMFirewallThresholdConfigApplyFailed NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "Firewall threshold configuration apply failed. Certain threshold values are unchanged. Contextual data provided with this event may indicate the cause of this failure. Collect error logs (vsfwd.log) when the host received firewall config. Force sync firewall config using ForceSync API/UI. See kb.vmware.com/kb/2125437 . + If the issue persists, please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/653." + ::= { vmwNsxMFirewallPrefix 58 } + +vmwNsxMUnsupportedIPsetConfigured NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "Whenever an IP address 0.0.0.0 or 0.0.0.0/32 is configured as IPSet. + KB article: https://ikb.vmware.com/kb/53157 + Action: Information-only event. No action required. Workaround to this issue documented in KB article." + ::= { vmwNsxMFirewallPrefix 59 } + -- -- Edge related traps -- @@ -1291,7 +1785,9 @@ vmwNsxMEdgeNoVmServing NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1308,8 +1804,10 @@ vmwNsxMEdgeGatewayCreated NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid - } + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } STATUS current DESCRIPTION "Edge Gateway created. @@ -1323,7 +1821,9 @@ vmwNsxMEdgeVmBadState NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1340,7 +1840,9 @@ vmwNsxMEdgeVmCommFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1356,7 +1858,9 @@ vmwNsxMEdgeVmCnfgChanged NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1372,7 +1876,9 @@ vmwNsxMEdgeGatewayDeleted NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1387,7 +1893,9 @@ vmwNsxMEdgeGatewayReDeployed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1402,7 +1910,9 @@ vmwNsxMEdgeVmPowerOff NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1417,7 +1927,9 @@ vmwNsxMEdgeApplianceSizeChanged NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1433,7 +1945,9 @@ vmwNsxMEdgeUpgrade51x NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1449,7 +1963,9 @@ vmwNsxMEdgeLicenseChanged NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1465,7 +1981,9 @@ vmwNsxMEdgeApplianceMoved NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1480,7 +1998,9 @@ vmwNsxMEdgeApplianceNotFound NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1496,7 +2016,9 @@ vmwNsxMEdgeVMHealthCheckMiss NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1513,7 +2035,9 @@ vmwNsxMEdgeHealthCheckMiss NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1530,7 +2054,9 @@ vmwNsxMEdgeCommAgentNotConnected NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1546,7 +2072,9 @@ vmwNsxMApplianceWithDifferentId NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1562,7 +2090,9 @@ vmwNsxMFirewallRuleModified NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1577,7 +2107,9 @@ vmwNsxMEdgeAntiAffinityRuleViolated NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1595,7 +2127,9 @@ vmwNsxMEdgeHaEnabled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1611,7 +2145,9 @@ vmwNsxMEdgeHaDisabled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1627,7 +2163,9 @@ vmwNsxMEdgeGatewayRecovered NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1643,7 +2181,9 @@ vmwNsxMEdgeVmRecovered NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1659,7 +2199,9 @@ vmwNsxMEdgeGatewayUpgraded NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1674,7 +2216,9 @@ vmwNsxMEdgeVmHlthChkDisabled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1694,7 +2238,9 @@ vmwNsxMEdgePrePublishFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1711,7 +2257,9 @@ vmwNsxMEdgeForcedSync NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1726,7 +2274,9 @@ vmwNsxMEdgeVmBooted NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1741,7 +2291,9 @@ vmwNsxMEdgeVmInBadState NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1757,7 +2309,9 @@ vmwNsxMEdgeVmCpuUsageIncreased NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1774,7 +2328,9 @@ vmwNsxMEdgeVmMemUsageIncreased NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1791,7 +2347,9 @@ vmwNsxMEdgeVmProcessFailure NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1808,7 +2366,9 @@ vmwNsxMEdgeVmSysTimeBad NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1823,7 +2383,9 @@ vmwNsxMEdgeVmSysTimeSync NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1838,7 +2400,9 @@ vmwNsxMEdgeAesniCryptoEngineUp NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1853,7 +2417,9 @@ vmwNsxMEdgeAesniCryptoEngineDown NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1868,7 +2434,9 @@ vmwNsxMEdgeVmOom NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1884,7 +2452,9 @@ vmwNsxMEdgeFileSysRo NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1900,7 +2470,9 @@ vmwNsxMEdgeHaCommDisconnected NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1918,7 +2490,9 @@ vmwNsxMEdgeHaSwitchOverSelf NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1942,7 +2516,9 @@ vmwNsxMEdgeHaSwitchOverActive NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1964,7 +2540,9 @@ vmwNsxMEdgeHaSwitchOverStandby NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -1987,7 +2565,9 @@ vmwNsxMEdgeMonitorProcessFailure NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2003,7 +2583,9 @@ vmwNsxMLbVirtualServerPoolUp NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2019,7 +2601,9 @@ vmwNsxMLbVirtualServerPoolDown NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2034,7 +2618,9 @@ vmwNsxMLbVirtualServerPoolWrong NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2049,7 +2635,9 @@ vmwNsxMLbPoolWarning NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2064,7 +2652,9 @@ vmwNsxMIpsecChannelUp NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2079,7 +2669,9 @@ vmwNsxMIpsecChannelDown NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2094,7 +2686,9 @@ vmwNsxMIpsecTunnelUp NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2109,7 +2703,9 @@ vmwNsxMIpsecTunnelDown NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2124,7 +2720,9 @@ vmwNsxMIpsecChannelUnknown NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2140,7 +2738,9 @@ vmwNsxMIpsecTunnelUnknown NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2155,7 +2755,9 @@ vmwNsxMGlobalLbMemberUp NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2171,7 +2773,9 @@ vmwNsxMGlobalLbMemberWarning NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2186,7 +2790,9 @@ vmwNsxMGlobalLbMemberDown NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2201,7 +2807,9 @@ vmwNsxMGlobalLbMemberUnknown NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2216,7 +2824,9 @@ vmwNsxMGlobalLbPeerUp NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2232,7 +2842,9 @@ vmwNsxMGlobalLbPeerDown NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2247,7 +2859,9 @@ vmwNsxMDhcpServiceDisabled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2262,7 +2876,9 @@ vmwNsxMEdgeResourceReservationFailure NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2284,7 +2900,9 @@ vmwNsxMEdgeSplitBrainDetected NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2305,7 +2923,9 @@ vmwNsxMEdgeSplitBrainRecovered NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2324,7 +2944,9 @@ vmwNsxMEdgeSplitBrainRecoveryAttempt NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2340,7 +2962,9 @@ vmwNsxMEdgeResourceReservationSuccess NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2354,7 +2978,7 @@ vmwNsxMEdgeResourceReservationSuccess NOTIFICATION-TYPE Home > Hosts and Clusters > [Cluster-name] > Monitor > Resource Reservation. Action required: None" ::= { vmwNsxMEdgePrefix 65 } - + vmwNsxMEdgeSddcChannelUp NOTIFICATION-TYPE OBJECTS { vmwNsxMEventCode, @@ -2362,7 +2986,9 @@ vmwNsxMEdgeSddcChannelUp NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2379,7 +3005,9 @@ vmwNsxMEdgeSddcChannelDown NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2392,6 +3020,332 @@ vmwNsxMEdgeSddcChannelDown NOTIFICATION-TYPE ::= { vmwNsxMEdgePrefix 67 } +vmwNsxMEdgeDuplicateIpDetected NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + "The NSX Edge IP has been assigned to another device on the network. MAC address of the conflicting device is provided. + Action required: Change the IP address of the other device on network. + Frequency: Once when the Edge detects the duplication of its IP by another macAddress in the same network. + URL: Nil" + ::= { vmwNsxMEdgePrefix 68 } + + +vmwNsxMEdgeDuplicateIpResolved NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + "NSX Edge Duplicate IP address issue is resolved. + Action required: None + Frequency: Once when the Edge detects the duplication is resolved + URL: Nil" + ::= { vmwNsxMEdgePrefix 69 } + +vmwNsxMEdgeBgpNeighborUp NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + + "Raised when BGP neighbor is up. + BGP neighbor IP address in the eventSourceId tells us for which neighbor this event is getting raised. + Action required: None" + ::= { vmwNsxMEdgePrefix 70 } + +vmwNsxMEdgeBgpNeighborDown NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + + "Raised when BGP neighbor is down. Once per neighbor. + BGP neighbor IP address in the eventSourceId tells us for which neighbor this event is getting raised. + Action required: None" + ::= { vmwNsxMEdgePrefix 71 } + +vmwNsxMEdgeBgpNeighborASMismatch NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + + "Raised when there is a mismatch in AS number configured. Raised repeatedly when BGP neighbor is getting established. + BGP neighbor IP address in the eventSourceId tells us for which neighbor this event is getting raised. + Action required: Correct the configured AS number" + ::= { vmwNsxMEdgePrefix 72 } + +vmwNsxMEdgeOSPFNeighborUp NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + + "Raised when OSPF neighbor is up. + OSPF router Id in the eventSourceId tells us for which neighbor this event is getting raised. + Action required: None" + ::= { vmwNsxMEdgePrefix 73 } + +vmwNsxMEdgeOSPFNeighborDown NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + + "Raised when OSPF neighbor is down. + OSPF router Id in the eventSourceId tells us for which neighbor this event is getting raised. + Action required: None" + ::= { vmwNsxMEdgePrefix 74 } + +vmwNsxMEdgeOSPFNeighborMTUMismatch NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + + "Raised when there is a MTU mismatch in neighbor ship request. + OSPF router Id in the eventSourceId tells us for which neighbor this event is getting raised. + Action required: Correct the MTU configured." + ::= { vmwNsxMEdgePrefix 75 } + +vmwNsxMEdgeOSPFNeighborAreaIdMisMatch NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + + "Raised when there is a areaId mismatch in neighbor ship request. + OSPF router Id in the eventSourceId tells us for which neighbor this event is getting raised. + Action required: Correct the areaId configured." + ::= { vmwNsxMEdgePrefix 76 } + +vmwNsxMEdgeOSPFNeighborHelloTimerMisMatch NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + + "Raised when there is hello timer mismatch in neighbor ship request. + OSPF router Id in the eventSourceId tells us for which neighbor this event is getting raised. + Action required: Correct the hello timer configured." + ::= { vmwNsxMEdgePrefix 77 } + +vmwNsxMEdgeOSPFNeighborDeadTimerMisMatch NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + + "Raised when there is dead timer mismatch in neighbor ship request. + OSPF router Id in the eventSourceId tells us for which neighbor this event is getting raised. + Action required: Correct the dead timer configured." + ::= { vmwNsxMEdgePrefix 78 } + +vmwNsxMEdgeL2vpnTunnelUp NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + + "Raised when the l2vpn tunnel is up. + Action required: None" + ::= { vmwNsxMEdgePrefix 79 } + +vmwNsxMEdgeL2vpnTunnelDown NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + + "Raised when the l2vpn tunnel is down. + We can debug why the l2vpn tunnel is down using the following cli commands, + show service l2vpn, + show configuration l2vpn, + show service l2vpn bridge + Action required: None." + ::= { vmwNsxMEdgePrefix 80 } + +vmwNsxMEdgeHAForceStandbyRemoved NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + + "A notification generated when forced standby for edge + enforced by NSX Manager gets removed. + Action required: None." + ::= { vmwNsxMEdgePrefix 81 } + +vmwNsxMEdgeHAForceStandbyRemovalFailed NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + + "Raised when the force standby removal for edge failed. + Action required: None." + ::= { vmwNsxMEdgePrefix 82 } + + +vmwNsxMEdgeVmBADStateRecovered NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + + "Raised when edge VM is recovered from bad state. + Action required: None." + ::= { vmwNsxMEdgePrefix 83 } + +vmwNsxMEdgeVmBADStateAutoHealRecoveryDisabled NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + + "Raised when VM can not be recovered from bad state after system specified retry of auto recovery ForceSync operation. + Action required: Trigger force sync to recover edge VM from bad state. To trigger force sync from UI see + (https://docs.vmware.com/en/VMware-NSX-for-vSphere/6.2/com.vmware.nsx.admin.doc/GUID-21FF2937-4CDF-491C-933E-8F44E21ED55E.html) + or call the API (POST https:///api/4.0/edges/?action=forcesync)" + ::= { vmwNsxMEdgePrefix 84 } + vmwNsxMEdgeHaInUseVnicChanged NOTIFICATION-TYPE OBJECTS { vmwNsxMEventCode, @@ -2399,7 +3353,9 @@ vmwNsxMEdgeHaInUseVnicChanged NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType } STATUS current DESCRIPTION @@ -2410,6 +3366,182 @@ vmwNsxMEdgeHaInUseVnicChanged NOTIFICATION-TYPE Action required: None." ::= { vmwNsxMEdgePrefix 85 } +vmwNsxMEdgeHaCommConnected NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + "A notification generated when Edge HighAvailability + communication channel is established with peer node. + Action required: None." + ::= { vmwNsxMEdgePrefix 86 } + +vmwNsxMEdgeVmRenameFailed NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + "Raised when Edge VM rename operation failed. + Given Edge name has invalid characters or exceeds + maximum number of characters permitted. There is + no functionality effect on the Edge. User may + choose a shorter name and rename the Edge. + Action required: None." + ::= { vmwNsxMEdgePrefix 87 } + +vmwNsxMEdgeBgpNeighborshipError NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + "Raised when something goes wrong in neighborship establishment. + Error message will have error code and sub error code. BGP neighbor IP + address in the eventSourceId tells us for which neighbor this event is + getting raised. + vmwNsxMEventMessage for example will contain following details: + (Error when establishing BGP neighborship with neighbor 10.20.30.40 + having AS number 1201 with error code 6, error sub code 5.) + Action required: The error code given in message are standard error codes. + Act accordingly as per the error codes." + ::= { vmwNsxMEdgePrefix 88 } + +vmwNsxMEdgeVmBadStateNotRecovered NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + "Raised when failed to recover NSX Edge VM from Bad State after force sync. + Action required: None." + ::= { vmwNsxMEdgePrefix 89 } + +vmwNsxMEdgeVmDcnOutOfSync NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + "Raised when GroupingObject sync is timed out on NSX Edge VM. + Action required: None." + ::= { vmwNsxMEdgePrefix 90 } + +vmwNsxMEdgeConsumedResourcesMissingInInventory NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + "Raised when missing or deleted resources from inventory are found used + in NSX Edges. + Action required: Please reconfigure these NSX Edges to use existing + resources. Refer to NSX Manager logs for the complete list of missing + resources." + ::= { vmwNsxMEdgePrefix 91 } + + +vmwNsxMEdgeIpsecDeprecatedComplianceSuiteInUse NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + "Raised when a deprecated compliance suite is used in an IPSec site in + NSX Edges. + Action required: Please reconfigure IPSec site to use supported + compliance suite." + ::= { vmwNsxMEdgePrefix 92 } + +vmwNsxMEdgeConnectedToMultipleTZHavingSameClusters NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + "Raised when a NSX Distributed Logical Router is connected to multiple + transport zones having same clusters. + Action required: None." + ::= { vmwNsxMEdgePrefix 93 } + +vmwNsxMEdgeConnectedToMultipleTZHavingDifferentClusters NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + "Raised when a NSX Distributed Logical Router is connected to multiple + transport zones having different clusters. This may cause network + disruption on clusters which are not common to all transport zones. + Action required: Please fix the configuration by either reconfiguring + transport zones to have same clusters or by connecting NSX Distributed + Logical Router to a single transport zone." + ::= { vmwNsxMEdgePrefix 94 } + -- -- Endpoint related traps -- @@ -2434,7 +3566,10 @@ vmwNsxMEndpointThinAgentEnabled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2448,7 +3583,10 @@ vmwNsxMGuestIntrspctnEnabled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2463,7 +3601,10 @@ vmwNsxMGuestIntrspctnIncompatibleEsx NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2478,7 +3619,10 @@ vmwNsxMGuestIntrspctnEsxConnFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2493,7 +3637,10 @@ vmwNsxMGuestIntrspctnStatusRcvFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2508,7 +3655,10 @@ vmwNsxMEsxModuleEnabled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2522,7 +3672,10 @@ vmwNsxMEsxModuleUninstalled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2536,7 +3689,10 @@ vmwNsxMGuestIntrspctnHstMxMssngRep NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2551,7 +3707,10 @@ vmwNsxMEndpointUndefined NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2582,7 +3741,10 @@ vmwNsxMEamGenericAlarm NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2617,7 +3779,10 @@ vmwNsxMFabricDplymntStatusChanged NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2637,7 +3802,10 @@ vmwNsxMFabricDplymntUnitCreated NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2655,7 +3823,10 @@ vmwNsxMFabricDplymntUnitUpdated NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2673,7 +3844,10 @@ vmwNsxMFabricDplymntUnitDestroyed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2690,7 +3864,10 @@ vmwNsxMDataStoreNotCnfgrdOnHost NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2708,7 +3885,10 @@ vmwNsxMFabricDplymntInstallationFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2728,7 +3908,10 @@ vmwNsxMFabricAgentCreated NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2745,7 +3928,10 @@ vmwNsxMFabricAgentDestroyed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2762,7 +3948,10 @@ vmwNsxMFabricSrvceNeedsRedplymnt NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2781,7 +3970,10 @@ vmwNsxMUpgradeOfDplymntFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2802,7 +3994,10 @@ vmwNsxMFabricDependenciesNotInstalled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2819,7 +4014,10 @@ vmwNsxMFabricErrorNotifSecBfrUpgrade NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2837,7 +4035,10 @@ vmwNsxMFabricErrCallbackNtRcvdUpgrade NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2856,7 +4057,10 @@ vmwNsxMFabricErrCallbackNtRcvdUninstall NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2874,7 +4078,10 @@ vmwNsxMFabricUninstallServiceFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2893,7 +4100,10 @@ vmwNsxMFabricErrorNotifSecBfrUninstall NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2912,7 +4122,10 @@ vmwNsxMFabricServerRebootUninstall NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2930,7 +4143,10 @@ vmwNsxMFabricServerRebootUpgrade NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2948,7 +4164,10 @@ vmwNsxMFabricConnEamFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2969,7 +4188,10 @@ vmwNsxMFabricConnEamRestored NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -2987,7 +4209,10 @@ vmwNsxMFabricPreUninstallCleanUpFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3003,7 +4228,10 @@ vmwNsxMFabricBackingEamNotFound NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3016,6 +4244,46 @@ vmwNsxMFabricBackingEamNotFound NOTIFICATION-TYPE Frequency of traps: Once per cluster." ::= { vmwNsxMFabricPrefix 22 } +vmwNsxMFabricVibManualInstallationRequired NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "This trap is generated when an attempt is made to upgrade or uninstall + NSX vibs on stateless host using EAM. All stateless host should be + prepared using the auto deploy feature (Refer : https://kb.vmware.com/s/article/2005131). + Fix configuration using auto deploy feature and use the resolve API to resolve the alarm. + Action required: Use the resolve API to resolve the alarm. + Frequency of traps: Once per host." + ::= { vmwNsxMFabricPrefix 23 } + +vmwNsxMFabricUninstallDeploymentUnit NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "Deployment unit fabric state is UNINSTALLED and health Status is SUCCEEDED. Resolve this alarm to complete uninstallation. + Frequency of traps: Once per cluster." + ::= { vmwNsxMFabricPrefix 24 } + -- -- DeploymentPlugin related traps -- @@ -3041,7 +4309,10 @@ vmwNsxMDepPluginIpPoolExhausted NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3066,7 +4337,10 @@ vmwNsxMDepPluginGenericAlarm NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3084,7 +4358,10 @@ vmwNsxMDepPluginGenericException NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3102,7 +4379,10 @@ vmwNsxMDepPluginVmReboot NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3137,7 +4417,10 @@ vmwNsxMMessagingConfigFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3152,7 +4435,10 @@ vmwNsxMMessagingReconfigFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3167,7 +4453,10 @@ vmwNsxMMessagingConfigFailedNotifSkip NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3182,7 +4471,10 @@ vmwNsxMMessagingInfraUp NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3204,7 +4496,10 @@ vmwNsxMMessagingInfraDown NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3225,7 +4520,10 @@ vmwNsxMMessagingDisabled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3266,7 +4564,10 @@ vmwNsxMServiceComposerPolicyOutOfSync NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3288,7 +4589,10 @@ vmwNsxMServiceComposerPolicyDeleted NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3306,7 +4610,10 @@ vmwNsxMServiceComposerFirewallPolicyOutOfSync NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3329,7 +4636,10 @@ vmwNsxMServiceComposerNetworkPolicyOutOfSync NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3353,7 +4663,10 @@ vmwNsxMServiceComposerGuestPolicyOutOfSync NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3377,7 +4690,10 @@ vmwNsxMServiceComposerOutOfSync NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3400,7 +4716,10 @@ vmwNsxMServiceComposerOutOfSync NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3422,7 +4741,10 @@ vmwNsxMServiceComposerOutOfSyncDraftRollback NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3443,7 +4765,10 @@ vmwNsxMServiceComposerOutOfSyncSectionDeletionFailure NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3465,7 +4790,10 @@ vmwNsxMServiceComposerOutOfSyncPrecedenceChangeFailure NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3487,7 +4815,10 @@ vmwNsxMServiceComposerOutOfSyncDraftSettingFailure NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3525,7 +4856,10 @@ vmwNsxMInconsistentSvmAlarm NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3549,7 +4883,10 @@ vmwNsxMSvmRestartAlarm NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3571,7 +4908,10 @@ vmwNsxMSvmAgentUnavailable NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3606,7 +4946,10 @@ vmwNsxMVmAddedToSg NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3621,7 +4964,10 @@ vmwNsxMVmRemovedFromSg NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3654,7 +5000,10 @@ vmwNsxMFullUniversalSyncFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3674,7 +5023,10 @@ vmwNsxMSecondaryDown NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3693,7 +5045,10 @@ vmwNsxMUniversalSyncFailedForEntity NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3706,6 +5061,46 @@ vmwNsxMUniversalSyncFailedForEntity NOTIFICATION-TYPE a NSX manager on which sync failure is seen." ::= { vmwNsxMUniversalSyncPrefix 3 } +vmwNsxMUniversalSyncStoppedOnSecondary NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "Secondary NSX manager is no longer receiving periodic universal sync updates. + IP address of the NSX manager is present in event's message variable. + Action required: Kindly check NSX manager logs and universal configuration on + the primary NSX manager to check if the secondary NSX manager has got removed. + Frequency of traps: This trap is generated one every 4 hours if secondary NSX + manager has not received universal sync updates for more than 4 hours." + ::= { vmwNsxMUniversalSyncPrefix 4 } + +vmwNsxMUniversalSyncResumedOnSecondary NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "Secondary NSX manager has resumed receiving periodic universal sync updates. + Frequency of traps: This trap is generated whenever communication between + primary and secondary managers resumes." + ::= { vmwNsxMUniversalSyncPrefix 5 } -- -- AsyncRest related traps -- @@ -3730,7 +5125,10 @@ vmwNsxMServerUp NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3765,7 +5163,10 @@ vmwNsxMExtensionRegistered NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3784,7 +5185,10 @@ vmwNsxMExtensionUpdated NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3869,7 +5273,10 @@ vmwNsxMSamDataCollectionEnabled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3886,7 +5293,10 @@ vmwNsxMSamDataCollectionDisabled NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3904,7 +5314,10 @@ vmwNsxMSamDataStoppedFlowing NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3926,7 +5339,10 @@ vmwNsxMSamDataResumedFlowing NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3959,7 +5375,10 @@ vmwNsxMUsvmHeartbeatStopped NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3977,7 +5396,10 @@ vmwNsxMUsvmHeartbeatResumed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -3994,7 +5416,10 @@ vmwNsxMUsvmReceivedHello NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4028,7 +5453,10 @@ vmwNsxMUpgradeSuccess NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4043,7 +5471,10 @@ vmwNsxMRestoreSuccess NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4058,7 +5489,10 @@ vmwNsxMDuplicateIp NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4068,6 +5502,47 @@ vmwNsxMDuplicateIp NOTIFICATION-TYPE address is being used by another machine in the same network" ::= { vmwNsxMVsmCorePrefix 3 } +vmwNsxMCPUHigh NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "NSX Manager CPU usage is currently high.CPU usage is based on load across all cores. + Action: If NSX Manager is facing performance issue, please collect the technical + support logs for NSX Manager and the host, and contact VMware technical support. + Frequency: This is triggered whenever NSX Manager CPU is above high threshold for consecutive 5 intervals. + Default value of high threshold and interval are 80% and 1 minute respectively." + ::= { vmwNsxMVsmCorePrefix 12 } + +vmwNsxMCPUNormal NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "NSX Manager CPU usage is back to normal.CPU usage is based on load across all cores. + Action: None + Frequency: This is triggered whenever NSX Manager CPU is below high threshold after 1 interval from CPU being above high threshold. + Default value of high threshold and interval are 80% and 1 minute respectively." + ::= { vmwNsxMVsmCorePrefix 13 } + vmwNsxMVirtualMachineMarkedAsSystemResource NOTIFICATION-TYPE OBJECTS { vmwNsxMEventCode, @@ -4075,7 +5550,10 @@ vmwNsxMVirtualMachineMarkedAsSystemResource NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4092,7 +5570,10 @@ vmwNsxMScaleAboveSupportedLimits NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4108,7 +5589,10 @@ vmwNsxMScaleAboveThreshold NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4117,6 +5601,7 @@ vmwNsxMScaleAboveThreshold NOTIFICATION-TYPE Frequency: This is triggered every hour if any new parameters cross the set threshold value" ::= { vmwNsxMVsmCorePrefix 6 } + vmwNsxMScaleNormalized NOTIFICATION-TYPE OBJECTS { vmwNsxMEventCode, @@ -4124,7 +5609,10 @@ vmwNsxMScaleNormalized NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4133,6 +5621,61 @@ vmwNsxMScaleNormalized NOTIFICATION-TYPE Frequency: This is triggered every hour if any new parameters return to normal after being above the set threshold or the supported value" ::= { vmwNsxMVsmCorePrefix 7 } +vmwNsxMScaleNotEqualToRecommendedValue NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "The scale value(s) of the mentioned parameter(s) is not matching the recommended value + Action: Increase/Decrease number of objects for the parameter(s) mentioned, to match with recommended value. Please refer NSX Administration guide. + Frequency: This is triggered every hour if any new parameters does not match the recommended value" + ::= { vmwNsxMVsmCorePrefix 8 } + +vmwNsxMCertificateExpired NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + "Certificate with mentioned id has expired. + Action: Replace expired certificate. Please refer to NSX Administration and API guide for details on certificate related operations. + Frequency: This is triggered every day until expired certificate is replaced." + ::= { vmwNsxMVsmCorePrefix 10 } + +vmwNsxMCertificateAboutToExpire NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType + } + STATUS current + DESCRIPTION + "Certificate with mentioned id will expire on mentioned date. + Action: Replace expiring certificate. Please refer to NSX Administration and API guide for details on certificate related operations. + Frequency: This is triggered every day until expiring certificate is replaced." + ::= { vmwNsxMVsmCorePrefix 11 } + -- -- Vxlan related traps -- @@ -4157,7 +5700,10 @@ vmwNsxMVxlanLogicalSwitchImproperlyCnfg NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4183,7 +5729,10 @@ vmwNsxMVxlanLogicalSwitchProperlyCnfg NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4202,7 +5751,10 @@ vmwNsxMVxlanInitFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4221,7 +5773,10 @@ vmwNsxMVxlanPortInitFailed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4240,7 +5795,10 @@ vmwNsxMVxlanInstanceDoesNotExist NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4260,7 +5818,10 @@ vmwNsxMVxlanLogicalSwitchWrkngImproperly NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4282,7 +5843,10 @@ vmwNsxMVxlanTransportZoneIncorrectlyWrkng NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4298,7 +5862,10 @@ vmwNsxMVxlanTransportZoneNotUsed NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4316,7 +5883,10 @@ vmwNsxMVxlanOverlayClassMissingOnDvs NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4336,7 +5906,10 @@ vmwNsxMVxlanControllerRemoved NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4352,7 +5925,10 @@ vmwNsxMVxlanControllerConnProblem NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4371,7 +5947,10 @@ vmwNsxMVxlanControllerInactive NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4392,7 +5971,10 @@ vmwNsxMVxlanControllerActive NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4411,7 +5993,10 @@ vmwNsxMVxlanVmknicMissingOrDeleted NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4431,7 +6016,10 @@ vmwNsxMVxlanInfo NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4455,7 +6043,10 @@ vmwNsxMVxlanVmknicPortGrpMissing NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4475,7 +6066,10 @@ vmwNsxMVxlanVmknicPortGrpAppears NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4493,7 +6087,10 @@ vmwNsxMVxlanConnDown NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4526,7 +6123,10 @@ vmwNsxMBackingPortgroupMissing NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4547,7 +6147,10 @@ vmwNsxMBackingPortgroupReappears NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4565,7 +6168,10 @@ vmwNsxMManagedObjectIdChanged NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4583,7 +6189,10 @@ vmwNsxMHighLatencyOnDisk NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4603,7 +6212,10 @@ vmwNsxMHighLatencyOnDiskResolved NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4620,7 +6232,10 @@ vmwNsxMControllerVmPoweredOff NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4643,7 +6258,10 @@ vmwNsxMControllerVmDeleted NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4666,7 +6284,10 @@ vmwNsxMVxlanConfigNotSet NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4687,7 +6308,10 @@ vmwNsxMVxlanPortgroupDeleted NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -4707,13 +6331,16 @@ vmwNsxMVxlanVDSandPgMismatch NOTIFICATION-TYPE vmwNsxMEventMessage, vmwNsxMEventSeverity, vmwNsxMEventComponent, - vmwNsxMUuid + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION "DESCRIPTION: NSX Manager will raise this event when the teaming policies of a VDS and it's associated VXLAN portgroup are not the same. - ACTION: Set the VXLAN portgroup teaming policy back to the original value. + ACTION: Set the VXLAN portgroup teaming policy back to the original value. Below is the workaround to correctly update the teaming policy in a deployed cluster: The supported method to correct teaming policy inconsistencies is to create and prepare a new NSX cluster with the required teaming policy, @@ -4725,6 +6352,95 @@ vmwNsxMVxlanVDSandPgMismatch NOTIFICATION-TYPE AFFECTS: The VXLAN traffic on the switch may be interrupted." ::= { vmwNsxMVxlanPrefix 28 } +vmwNsxMVxlanControllerDisconnected NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "DESCRIPTION: NSX Manager raises this event when the Controller VM is + Disconnected ie the controller can not reached from the NSX Manager. + ACTION: Make sure the IP is assigned to the controller VM and it is + reachable form the NSX Manager. + FREQUENCY: The event occurs when the Controller VM is powered off or not responding. + Minimum 40 secs between two disconnecet events. + AFFECTS: Controller cluster status might go to disconnected if a controller + Virtual Machine is disconnected. Any operation that requires an active + Controller Cluster may be affected." + ::= { vmwNsxMVxlanPrefix 29 } + +vmwNsxMVxlanControllerConnected NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "DESCRIPTION: NSX Manager will raise this informational event when the + controller VM is connected to controller cluster. + ACTION: No action to be taken. + FREQUENCY: Event occurs as controller is connected to controller-cluster. + Minimum 40 secs between two connecet events. + AFFECTS: None." + ::= { vmwNsxMVxlanPrefix 30 } + +vmwNsxMVxlanControllerVmPoweredOn NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "DESCRIPTION: NSX manager detected a Controller Virtual Machine is powered on from vCenter. + ACTION: None. + FREQUENCY: This event occurs when Controller Virtual Machine is powered On. + AFFECTS: Controller cluster status might go to disconnected if a controller Virtual Machine + is powered off. Any operation that requires an active Controller Cluster may be affected." + ::= { vmwNsxMVxlanPrefix 31 } + +vmwNsxMVxlanHostEvents NOTIFICATION-TYPE + OBJECTS { + vmwNsxMEventCode, + vmwNsxMEventTimestamp, + vmwNsxMEventMessage, + vmwNsxMEventSeverity, + vmwNsxMEventComponent, + vmwNsxMUuid, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP + } + STATUS current + DESCRIPTION + "DESCRIPTION: NSX manager receives a notification from the host informing MAC mismatch occurred. + ACTION: Contact the administrator to take following action: + (1) Look for VMs that caused this issue at hosts. + (2) If VMs are rouge, shut dowm these VMs. + FREQUENCY: Event is triggerred as MAC mismatch occurs at switchport on the hosts. + AFFECTS: Identify the VMs causing this issue." + ::= { vmwNsxMVxlanPrefix 32 } -- -- Domain Controller Event Log server related trap @@ -4837,13 +6553,13 @@ vmwNsxManagerMIBGroups OBJECT IDENTIFIER ::= { vmwNsxManagerMIBConformance 2 } -- compliance statements vmwNsxManagerMIBBasicCompliance MODULE-COMPLIANCE - STATUS deprecated + STATUS obsolete DESCRIPTION "The compliance statement for entities which implement VMWARE-NSX-MANAGER-MIB." MODULE -- this module MANDATORY-GROUPS { vmwNsxManagerNotificationInfoGroup1, - vmwNsxManagerNotificationGroup1 } + vmwNsxManagerNotificationGroup1 } ::= { vmwNsxManagerMIBCompliances 3 } vmwNsxManagerNotificationInfoGroup1 OBJECT-GROUP @@ -4854,7 +6570,10 @@ vmwNsxManagerNotificationInfoGroup1 OBJECT-GROUP vmwNsxMEventSeverity, vmwNsxMEventComponent, vmwNsxMUuid, - vmwNsxMCount + vmwNsxMCount, + vmwNsxMEventSourceID, + vmwNsxMEventSourceType, + vmwNsxMEventSourceIP } STATUS current DESCRIPTION @@ -5000,6 +6719,7 @@ vmwNsxManagerNotificationGroup1 NOTIFICATION-GROUP vmwNsxMFabricConnEamRestored, vmwNsxMFabricPreUninstallCleanUpFailed, vmwNsxMFabricBackingEamNotFound, + vmwNsxMFabricUninstallDeploymentUnit, vmwNsxMDepPluginIpPoolExhausted, vmwNsxMDepPluginGenericAlarm, vmwNsxMDepPluginGenericException, @@ -5096,7 +6816,7 @@ vmwNsxManagerNotificationGroup1 NOTIFICATION-GROUP vmwNsxManagerMIB630Compliance MODULE-COMPLIANCE - STATUS current + STATUS deprecated DESCRIPTION "The compliance statement for entities which implement VMWARE-NSX-MANAGER-MIB, see VMWARE-NSX-MANAGER-AGENTCAP-MIB" @@ -5140,4 +6860,240 @@ vmwNsxManagerNotificationGroup2 NOTIFICATION-GROUP "Group of objects describing notifications (traps, informs)." ::= { vmwNsxManagerMIBGroups 4 } + + +vmwNsxManagerMIB64Compliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for entities which implement + VMWARE-NSX-MANAGER-MIB, see VMWARE-NSX-MANAGER-AGENTCAP-MIB" + MODULE -- this module + MANDATORY-GROUPS { vmwNsxManagerNotificationInfoGroup1, + vmwNsxManagerNotificationGroup1, + vmwNsxManagerNotificationGroup2, + vmwNsxManagerNotificationGroup3 } + ::= { vmwNsxManagerMIBCompliances 5 } + + +vmwNsxManagerNotificationGroup3 NOTIFICATION-GROUP + NOTIFICATIONS { + vmwNsxMEdgeDuplicateIpDetected, + vmwNsxMEdgeDuplicateIpResolved, + vmwNsxMEdgeBgpNeighborUp, + vmwNsxMEdgeBgpNeighborDown, + vmwNsxMEdgeBgpNeighborASMismatch, + vmwNsxMEdgeOSPFNeighborUp, + vmwNsxMEdgeOSPFNeighborDown, + vmwNsxMEdgeOSPFNeighborMTUMismatch, + vmwNsxMEdgeOSPFNeighborAreaIdMisMatch, + vmwNsxMEdgeOSPFNeighborHelloTimerMisMatch, + vmwNsxMEdgeOSPFNeighborDeadTimerMisMatch, + vmwNsxMEdgeL2vpnTunnelUp, + vmwNsxMEdgeL2vpnTunnelDown, + vmwNsxMEdgeHAForceStandbyRemoved, + vmwNsxMEdgeHAForceStandbyRemovalFailed, + vmwNsxMEdgeVmBADStateRecovered, + vmwNsxMEdgeVmBADStateAutoHealRecoveryDisabled, + vmwNsxMFirewallMaxConcurrentConnectionsThresholdCrossed, + vmwNsxMFirewallProcessMemoryThresholdCrossed, + vmwNsxMFirewallCpuThresholdCrossCleared, + vmwNsxMFirewallMemThresholdCrossCleared, + vmwNsxMConnPerSecThrshldCrossCleared, + vmwNsxMFirewallMaxConcurrentConnectionsThresholdCrossCleared, + vmwNsxMFirewallProcessMemoryThresholdCrossCleared, + vmwNsxMFirewallThresholdConfigApplied, + vmwNsxMFirewallThresholdConfigApplyFailed, + vmwNsxMEdgeHaCommConnected, + vmwNsxMVxlanControllerDisconnected, + vmwNsxMVxlanControllerConnected, + vmwNsxMVxlanControllerVmPoweredOn, + vmwNsxMVxlanHostEvents, + vmwNsxMScaleNotEqualToRecommendedValue + } + STATUS current + DESCRIPTION + "Group of objects describing notifications (traps, informs)." + ::= { vmwNsxManagerMIBGroups 5 } + +vmwNsxManagerMIB636Compliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for entities which implement + VMWARE-NSX-MANAGER-MIB, see VMWARE-NSX-MANAGER-AGENTCAP-MIB" + MODULE -- this module + MANDATORY-GROUPS { vmwNsxManagerNotificationInfoGroup1, + vmwNsxManagerNotificationGroup1, + vmwNsxManagerNotificationGroup2, + vmwNsxManagerNotificationGroup3, + vmwNsxManagerNotificationGroup4 } + ::= { vmwNsxManagerMIBCompliances 6 } + + +vmwNsxManagerNotificationGroup4 NOTIFICATION-GROUP + NOTIFICATIONS { + vmwNsxMUniversalSyncStoppedOnSecondary, + vmwNsxMUniversalSyncResumedOnSecondary + } + STATUS current + DESCRIPTION + "Group of objects describing notifications (traps, informs)." + ::= { vmwNsxManagerMIBGroups 6 } + +vmwNsxManagerMIB641Compliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for entities which implement + VMWARE-NSX-MANAGER-MIB, see VMWARE-NSX-MANAGER-AGENTCAP-MIB" + MODULE -- this module + MANDATORY-GROUPS { vmwNsxManagerNotificationInfoGroup1, + vmwNsxManagerNotificationGroup1, + vmwNsxManagerNotificationGroup2, + vmwNsxManagerNotificationGroup3, + vmwNsxManagerNotificationGroup5 } + ::= { vmwNsxManagerMIBCompliances 7 } + + +vmwNsxManagerNotificationGroup5 NOTIFICATION-GROUP + NOTIFICATIONS { + vmwNsxMUniversalSyncStoppedOnSecondary, + vmwNsxMUniversalSyncResumedOnSecondary, + vmwNsxMCertificateExpired, + vmwNsxMCertificateAboutToExpire, + vmwNsxMCPUHigh, + vmwNsxMCPUNormal, + vmwNsxMUnsupportedIPsetConfigured + } + STATUS current + DESCRIPTION + "Group of objects describing notifications (traps, informs)." + ::= { vmwNsxManagerMIBGroups 7 } + +vmwNsxManagerMIB637Compliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for entities which implement + VMWARE-NSX-MANAGER-MIB, see VMWARE-NSX-MANAGER-AGENTCAP-MIB." + MODULE -- this module + MANDATORY-GROUPS { vmwNsxManagerNotificationInfoGroup1, + vmwNsxManagerNotificationGroup1, + vmwNsxManagerNotificationGroup2, + vmwNsxManagerNotificationGroup3, + vmwNsxManagerNotificationGroup4, + vmwNsxManagerNotificationGroup6} + ::= { vmwNsxManagerMIBCompliances 8 } + + +vmwNsxManagerNotificationGroup6 NOTIFICATION-GROUP + NOTIFICATIONS { + vmwNsxMUnsupportedIPsetConfigured + } + STATUS current + DESCRIPTION + "Group of objects describing notifications (traps, informs)." + ::= { vmwNsxManagerMIBGroups 8 } + +vmwNsxManagerMIB642Compliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for entities which implement + VMWARE-NSX-MANAGER-MIB, see VMWARE-NSX-MANAGER-AGENTCAP-MIB." + MODULE -- this module + MANDATORY-GROUPS { vmwNsxManagerNotificationInfoGroup1, + vmwNsxManagerNotificationGroup1, + vmwNsxManagerNotificationGroup2, + vmwNsxManagerNotificationGroup3, + vmwNsxManagerNotificationGroup5, + vmwNsxManagerNotificationGroup7} + ::= { vmwNsxManagerMIBCompliances 9 } + +vmwNsxManagerNotificationGroup7 NOTIFICATION-GROUP + NOTIFICATIONS { + vmwNsxMSsoTimeout, + vmwNsxMFabricVibManualInstallationRequired + } + STATUS current + DESCRIPTION + "Group of objects describing notifications (traps, informs)." + ::= { vmwNsxManagerMIBGroups 9 } + +vmwNsxManagerMIB645Compliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for entities which implement + VMWARE-NSX-MANAGER-MIB, see VMWARE-NSX-MANAGER-AGENTCAP-MIB." + MODULE -- this module + MANDATORY-GROUPS { vmwNsxManagerNotificationInfoGroup1, + vmwNsxManagerNotificationGroup1, + vmwNsxManagerNotificationGroup2, + vmwNsxManagerNotificationGroup3, + vmwNsxManagerNotificationGroup5, + vmwNsxManagerNotificationGroup7, + vmwNsxManagerNotificationGroup8} + ::= { vmwNsxManagerMIBCompliances 10 } + +vmwNsxManagerNotificationGroup8 NOTIFICATION-GROUP + NOTIFICATIONS { + vmwNsxMEdgeVmRenameFailed, + vmwNsxMEdgeBgpNeighborshipError + } + STATUS current + DESCRIPTION + "Group of objects describing notifications (traps, informs)." + ::= { vmwNsxManagerMIBGroups 10 } + +vmwNsxManagerMIB646Compliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for entities which implement + VMWARE-NSX-MANAGER-MIB, see VMWARE-NSX-MANAGER-AGENTCAP-MIB." + MODULE -- this module + MANDATORY-GROUPS { vmwNsxManagerNotificationInfoGroup1, + vmwNsxManagerNotificationGroup1, + vmwNsxManagerNotificationGroup2, + vmwNsxManagerNotificationGroup3, + vmwNsxManagerNotificationGroup5, + vmwNsxManagerNotificationGroup7, + vmwNsxManagerNotificationGroup8, + vmwNsxManagerNotificationGroup9} + ::= { vmwNsxManagerMIBCompliances 11 } + +vmwNsxManagerNotificationGroup9 NOTIFICATION-GROUP + NOTIFICATIONS { + vmwNsxMEdgeVmBadStateNotRecovered, + vmwNsxMEdgeVmDcnOutOfSync, + vmwNsxMEdgeConsumedResourcesMissingInInventory + } + STATUS current + DESCRIPTION + "Group of objects describing notifications (traps, informs)." + ::= { vmwNsxManagerMIBGroups 11 } + +vmwNsxManagerMIB647Compliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for entities which implement + VMWARE-NSX-MANAGER-MIB, see VMWARE-NSX-MANAGER-AGENTCAP-MIB." + MODULE -- this module + MANDATORY-GROUPS { vmwNsxManagerNotificationInfoGroup1, + vmwNsxManagerNotificationGroup1, + vmwNsxManagerNotificationGroup2, + vmwNsxManagerNotificationGroup3, + vmwNsxManagerNotificationGroup5, + vmwNsxManagerNotificationGroup7, + vmwNsxManagerNotificationGroup8, + vmwNsxManagerNotificationGroup9, + vmwNsxManagerNotificationGroup10} + ::= { vmwNsxManagerMIBCompliances 12 } + +vmwNsxManagerNotificationGroup10 NOTIFICATION-GROUP + NOTIFICATIONS { + vmwNsxMEdgeIpsecDeprecatedComplianceSuiteInUse, + vmwNsxMEdgeConnectedToMultipleTZHavingSameClusters, + vmwNsxMEdgeConnectedToMultipleTZHavingDifferentClusters + } + STATUS current + DESCRIPTION + "Group of objects describing notifications (traps, informs)." + ::= { vmwNsxManagerMIBGroups 12 } + END diff --git a/mibs/vmware/VMWARE-PRODUCTS-MIB b/mibs/vmware/VMWARE-PRODUCTS-MIB index 8eaba74eb2..27b5dcedf1 100644 --- a/mibs/vmware/VMWARE-PRODUCTS-MIB +++ b/mibs/vmware/VMWARE-PRODUCTS-MIB @@ -1,5 +1,5 @@ -- ********************************************************** --- Copyright 2007-2017 VMware, Inc. All rights reserved. +-- Copyright 2007-2018 VMware, Inc. All rights reserved. -- ********************************************************** VMWARE-PRODUCTS-MIB DEFINITIONS ::= BEGIN @@ -11,7 +11,7 @@ IMPORTS FROM VMWARE-ROOT-MIB; vmwProducts MODULE-IDENTITY - LAST-UPDATED "201710130000Z" + LAST-UPDATED "201806270000Z" ORGANIZATION "VMware, Inc" CONTACT-INFO "VMware, Inc @@ -26,6 +26,9 @@ vmwProducts MODULE-IDENTITY which are returned from SNMPv2-MIB sysObjectId for agents in specific VMware products. " + REVISION "201806270000Z" + DESCRIPTION + "Add vmwVrops snmp agent's sysObjectId value." REVISION "201710130000Z" DESCRIPTION "Changed vmwNSXManagerAppliance, vmwNSXManagerAppliance, and vmwNSXControllerAppliance oid." @@ -61,6 +64,9 @@ vmwServer OBJECT IDENTIFIER vmwVCOps OBJECT IDENTIFIER ::= { vmwProductSpecific 5 } +vmwVrops OBJECT IDENTIFIER + ::= { vmwProductSpecific 50 } + vmwGenericAppliance OBJECT IDENTIFIER ::= { vmwProductSpecific 6 } diff --git a/mibs/vmware/VMWARE-ROOT-MIB b/mibs/vmware/VMWARE-ROOT-MIB index 00e1c0c702..bb3f95f4bc 100644 --- a/mibs/vmware/VMWARE-ROOT-MIB +++ b/mibs/vmware/VMWARE-ROOT-MIB @@ -1,5 +1,5 @@ -- ********************************************************** --- Copyright 2007-2016 VMware, Inc. All rights reserved. +-- Copyright 2007-2017 VMware, Inc. All rights reserved. -- ********************************************************** VMWARE-ROOT-MIB DEFINITIONS ::= BEGIN @@ -9,7 +9,7 @@ IMPORTS FROM SNMPv2-SMI; vmware MODULE-IDENTITY - LAST-UPDATED "201611030000Z" + LAST-UPDATED "201808300000Z" ORGANIZATION "VMware, Inc" CONTACT-INFO "VMware, Inc @@ -17,13 +17,22 @@ vmware MODULE-IDENTITY Palo Alto, CA 94304 Tel: 1-877-486-9273 or 650-427-5000 Fax: 650-427-5001 - Web: http://communities.vmware.com/community/developer/forums/managementapi + Web: http://kb.vmware.com/kb/1013445 " DESCRIPTION "VMware managed object root assignements This module defines the VMware SNMP MIB root and its primary subtrees. " + REVISION "201808300000Z" + DESCRIPTION + "Arc vmwPerAppTunnel defined." + REVISION "201710300000Z" + DESCRIPTION + "Arc vmwNSXsys defined." + REVISION "201706070000Z" + DESCRIPTION + "Arc vmwHCX defined." REVISION "201611030000Z" DESCRIPTION "Arc vmwNetworkInsight defined." @@ -38,10 +47,10 @@ vmware MODULE-IDENTITY REVISION "200707300000Z" DESCRIPTION - "The initial revision. Prior version was released in + "The initial revision. Prior version was released in SMIv1 format as VMWARE-ROOT-MIB." ::= { enterprises 6876 } - + -- The parent oid of snmpv1 traps when sent in snmpv2/v3 -- vmwNotifications OBJECT IDENTIFIER ::= { vmware 0 } @@ -133,6 +142,24 @@ DESCRIPTION "Objects used by VMware vRealize Network Insight and related components." ::= { vmware 100 } +vmwHCX OBJECT-IDENTITY +STATUS current +DESCRIPTION + "Objects used by VMware HCX appliance and related components." +::= { vmware 110 } + +vmwNSXsys OBJECT-IDENTITY +STATUS current +DESCRIPTION + "Objects used by VMware NSX systems and related components." +::= { vmware 120 } + +vmwPerAppTunnel OBJECT-IDENTITY +STATUS current +DESCRIPTION + "Objects used by VMware PerApp Tunnel and related components." +::= { vmware 130 } + vmwExperimental OBJECT-IDENTITY STATUS current DESCRIPTION @@ -142,7 +169,7 @@ DESCRIPTION vmwDocumentation OBJECT-IDENTITY STATUS current DESCRIPTION - "Used in product documentation, examples." + "Used in product documentation, examples." ::= { vmware 750 } vmwObsolete OBJECT-IDENTITY diff --git a/mibs/vmware/VMWARE-VA-AGENTCAP-MIB b/mibs/vmware/VMWARE-VA-AGENTCAP-MIB index 598ec8ccfc..13314fd078 100644 --- a/mibs/vmware/VMWARE-VA-AGENTCAP-MIB +++ b/mibs/vmware/VMWARE-VA-AGENTCAP-MIB @@ -1,5 +1,5 @@ -- ********************************************************** --- Copyright 2008-2017 VMware, Inc. All rights reserved. +-- Copyright 2008-2020 VMware, Inc. All rights reserved. -- ********************************************************** VMWARE-VA-AGENTCAP-MIB DEFINITIONS ::= BEGIN @@ -12,7 +12,7 @@ IMPORTS AGENT-CAPABILITIES FROM SNMPv2-CONF; vmwVAAgentCapabilityMIB MODULE-IDENTITY - LAST-UPDATED "201710130000Z" + LAST-UPDATED "202003270000Z" ORGANIZATION "VMware, Inc" CONTACT-INFO "VMware, Inc @@ -25,9 +25,13 @@ vmwVAAgentCapabilityMIB MODULE-IDENTITY DESCRIPTION "This module defines agent capabilities for deployed VMware Virtual Appliance agents by release." + REVISION "202003270000Z" + DESCRIPTION + "Capabilities for VMware VSphere (Release 7.0) VCenter added." + REVISION "201710130000Z" DESCRIPTION - "Capabilities for VMware VSphere (Release 6.7) ESXi 2017 added." + "Capabilities for VMware VSphere (Release 6.7) VCenter added." REVISION "201604220000Z" DESCRIPTION @@ -41,6 +45,237 @@ vmwVAAgentCapabilityMIB MODULE-IDENTITY vmwVACapability OBJECT IDENTIFIER ::= { vmwVAAgentCapabilityMIB 1 } +-- +-- 2020 Release and follow up patch releases +-- + +vmwVCSA2020x AGENT-CAPABILITIES + PRODUCT-RELEASE + "7.0.x" + STATUS current + DESCRIPTION + "Release 7.0 for VMware Virtual Appliance (VCSA) supporting SNMPv1, SNMPv2c, and SNMPv3. + Added REST API configuration/status/test support for appliance similar to vicfg-snmp CLI, + Service is off by default, see 'systemctl status snmpcfgd' and systemctl enable/start to use. + Added a configuration option for HOST-RESOURCES-MIB added for reporting java processes clearly. + Remaining changes for this release were bug fixes. + " + REFERENCE + "http://www.vmware.com/products" + + -- RFC 3418 + SUPPORTS SNMPv2-MIB + INCLUDES { + snmpGroup, + systemGroup, + snmpCommunityGroup, + snmpBasicNotificationsGroup, + snmpWarmStartNotificationGroup + -- groups not supported; snmpSetGroup, snmpNotificationGroup + } + VARIATION snmpSetSerialNo + ACCESS not-implemented + DESCRIPTION "Agent provides read-only view of system information." + + VARIATION snmpTrapOID + ACCESS not-implemented + DESCRIPTION "Agent does not proxy other agents RFC1157 Trap-PDUs." + + VARIATION snmpTrapEnterprise + ACCESS not-implemented + DESCRIPTION "Agent does not proxy other agents RFC1157 Trap-PDUs." + + VARIATION snmpEnableAuthenTraps + SYNTAX INTEGER { disabled(2) } + ACCESS read-only + DESCRIPTION "Agent does not support authentication traps. Poll snmpInBadCommunityNames for same info." + -- which implies: + -- VARIATION authenticationFailure + -- ACCESS not-implemented + -- DESCRIPTION "Agent does not provide this notification. snmpEnableAuthenTraps will return disabled." + + -- ********************* ************ ************ *************** *** + -- RFC 2863 + SUPPORTS IF-MIB + INCLUDES { + ifGeneralInformationGroup, + linkUpDownNotificationsGroup + } + + VARIATION ifAdminStatus + ACCESS read-only + DESCRIPTION "Agent provides read-only view of administrative state for each physical interface." + + VARIATION ifLinkUpDownTrapEnable + ACCESS read-only + DESCRIPTION "Agent provides read-only view of system information." + + VARIATION ifAlias + ACCESS read-only + DESCRIPTION "ifIndexes may only change across reboot." + + VARIATION ifInUnknownProtos + ACCESS not-implemented + DESCRIPTION "This counter always returns 0." + + -- ifRcvAddressGroup is interface/media specific + VARIATION ifRcvAddressStatus + ACCESS not-implemented + DESCRIPTION "Required if media specific mib modules are implemented." + + VARIATION ifRcvAddressType + ACCESS not-implemented + DESCRIPTION "Required if media specific mib modules are implemented." + + -- ********************* ************ ************ *************** *** + -- RFC 4293 + SUPPORTS IP-MIB + INCLUDES { + ipSystemStatsGroup, + ipAddressGroup, + ipNetToPhysicalGroup, + ipDefaultRouterGroup, + icmpStatsGroup, + ipSystemStatsHCOctetGroup, + ipSystemStatsHCPacketGroup, + ipv4GeneralGroup, + ipv4IfGroup, + ipv4SystemStatsGroup, + ipv4SystemStatsHCPacketGroup, + ipv6GeneralGroup2, + ipv6IfGroup, + ipAddressPrefixGroup, + ipv6RouterAdvertGroup, + ipLastChangeGroup + } + -- VARIATION ipv6ScopeGroup + -- ACCESS not-implemented + + -- ********************* ************ ************ *************** *** + -- RFC 4292 + -- supports SNMPv2/3 Contexts for multiple instances + SUPPORTS IP-FORWARD-MIB + INCLUDES { + inetForwardCidrRouteGroup + } + + -- RFC 4113 + -- supports SNMPv2/3 Contexts for multiple instances + SUPPORTS UDP-MIB + -- The next two 32 bit counters will be fixed per bug report PR 890894 + -- VARIATION udpInDatagrams + -- ACCESS not-implemented, use udpHCInDatagrams + -- VARIATION udpOutDatagrams + -- ACCESS not-implemented, use udpHCOutDatagrams + INCLUDES { + udpBaseGroup, + udpEndpointGroup + } + + -- RFC 4022 + -- supports SNMPv2/3 Contexts for multiple instances + SUPPORTS TCP-MIB + INCLUDES { + tcpBaseGroup, + tcpConnectionGroup, + tcpListenerGroup + } + + -- RFC 2790 + -- NOTE: For storage larger than Integer32 (Terabyte) this agent will report INT_MAX + SUPPORTS HOST-RESOURCES-MIB + INCLUDES { + hrSystemGroup, + hrStorageGroup, + hrDeviceGroup, + hrSWRunGroup, + hrSWRunPerfGroup, + hrSWInstalledGroup -- updates once an hour + } + + VARIATION hrSystemNumUsers + ACCESS read-only + DESCRIPTION "Value reports number of active appliace shell sessions" + + VARIATION hrSystemDate + ACCESS read-only + DESCRIPTION "agent provides read only access" + + VARIATION hrSystemInitialLoadDevice + ACCESS read-only + DESCRIPTION "agent provides read only access" + + VARIATION hrSystemInitialLoadParameters + ACCESS read-only + DESCRIPTION "agent provides read only access" + + VARIATION hrStorageSize + ACCESS read-only + DESCRIPTION "agent provides read only access" + + VARIATION hrSWRunStatus + ACCESS read-only + DESCRIPTION "agent provides read only access" + + -- hrDeviceStatus reports unknown for: cpu, nic either running/unknown. + -- disk reports running, warning, down, unknown + -- device error counters do not account for all failure cases + + VARIATION hrSWOSIndex + ACCESS not-implemented + DESCRIPTION "No operatingSystem entry exists in hrSWRunGroup hrSWRunTable" + + VARIATION hrFSLastFullBackupDate + ACCESS not-implemented + DESCRIPTION "is not implemented" + + VARIATION hrFSLastPartialBackupDate + ACCESS not-implemented + DESCRIPTION "is not implemented" + + VARIATION hrPrinterStatus + ACCESS not-implemented + DESCRIPTION "is not implemented" + + VARIATION hrPrinterDetectedErrorState + ACCESS not-implemented + DESCRIPTION "is not implemented" + + -- ********************* ************ ************ *************** *** + -- RFC 4133 + SUPPORTS ENTITY-MIB + INCLUDES { + entityPhysicalGroup, + entityPhysical2Group, + entityPhysical3Group, + entityGeneralGroup + } + -- VARIATION entityNotificationsGroup + -- ACCESS not-implemented + -- VARIATION entityMappingGroup + -- ACCESS not-implemented + + -- ********************* ************ ************ *************** *** + -- REVISION 201008020000Z + SUPPORTS VMWARE-SYSTEM-MIB + INCLUDES { + vmwSystemGroup + } + -- VARIATION vmwProdUpdate + -- ACCESS not-implemented + -- VARIATION vmwProdPatch + -- ACCESS not-implemented + + -- ********************* ************ ************ *************** *** + -- REVISION 201602030000Z + SUPPORTS VMWARE-VCHA-MIB + INCLUDES { + vmwVchaNotificationInfoGroup, + vmwVchaNotificationGroup + } + + ::= { vmwVACapability 9 } + -- -- 2017 Release and follow up patch releases -- diff --git a/mibs/vmware/VMWARE-VCOPS-EVENT-MIB b/mibs/vmware/VMWARE-VCOPS-EVENT-MIB index 49d8219c66..8b9fc65c7c 100644 --- a/mibs/vmware/VMWARE-VCOPS-EVENT-MIB +++ b/mibs/vmware/VMWARE-VCOPS-EVENT-MIB @@ -54,7 +54,7 @@ vmwVcopsMIB MODULE-IDENTITY -- Group 0: Alerts sent as traps vmwareAlertTrap OBJECT-IDENTITY - STATUS current + STATUS obsolete DESCRIPTION "This group is actually the prefix one uses when creating enterprise-specific trap OID's for an SNMPv2 trap. It is @@ -67,7 +67,7 @@ vmwareAlertTrap OBJECT-IDENTITY -- Generic data, in var-binds, that is associated with EVERY Alert -- vmwareGenericAlertData OBJECT-IDENTITY - STATUS current + STATUS obsolete DESCRIPTION "This members of this group are the OIDs for VarBinds that contain data for ALL Alerts." @@ -76,7 +76,7 @@ vmwareGenericAlertData OBJECT-IDENTITY vmwareAlertAliveServerName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "The name of the vRealize Operations server that generated this alert." ::= { vmwareGenericAlertData 1 } @@ -84,7 +84,7 @@ vmwareAlertAliveServerName OBJECT-TYPE vmwareAlertEntityName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "The Entity name about which this alert was generated." ::= { vmwareGenericAlertData 2 } @@ -92,7 +92,7 @@ vmwareAlertEntityName OBJECT-TYPE vmwareAlertEntityType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "The Entity type about which this alert was generated." ::= { vmwareGenericAlertData 3 } @@ -100,7 +100,7 @@ vmwareAlertEntityType OBJECT-TYPE vmwareAlertTimestamp OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "The timestamp of the alert in UTC format." ::= { vmwareGenericAlertData 4 } @@ -108,7 +108,7 @@ vmwareAlertTimestamp OBJECT-TYPE vmwareAlertCriticality OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "A text string describing the alert criticality level." ::= { vmwareGenericAlertData 5 } @@ -116,7 +116,7 @@ vmwareAlertCriticality OBJECT-TYPE vmwareAlertRootCause OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "A text string describing the root-cause of the alert that was generated." ::= { vmwareGenericAlertData 6 } @@ -124,7 +124,7 @@ vmwareAlertRootCause OBJECT-TYPE vmwareAlertURL OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "The URL of the 'Alert Summary' page of the alert that was generated." ::= { vmwareGenericAlertData 7 } @@ -132,7 +132,7 @@ vmwareAlertURL OBJECT-TYPE vmwareAlertID OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "The unique vRealize Operations identifier of the alert that was generated." ::= { vmwareGenericAlertData 8 } @@ -140,7 +140,7 @@ vmwareAlertID OBJECT-TYPE vmwareAlertMessage OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "The info message of the alert that was generated." ::= { vmwareGenericAlertData 9 } @@ -148,7 +148,7 @@ vmwareAlertMessage OBJECT-TYPE vmwareAlertType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "The textual type description of the alert that was generated." ::= { vmwareGenericAlertData 10 } @@ -157,7 +157,7 @@ vmwareAlertType OBJECT-TYPE vmwareAlertSubtype OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "The textual subtype description of the alert that was generated." ::= { vmwareGenericAlertData 11 } @@ -165,7 +165,7 @@ vmwareAlertSubtype OBJECT-TYPE vmwareAlertHealth OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "Health badge state." ::= { vmwareGenericAlertData 12 } @@ -173,7 +173,7 @@ vmwareAlertHealth OBJECT-TYPE vmwareAlertRisk OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "Risk badge state." ::= { vmwareGenericAlertData 13 } @@ -181,7 +181,7 @@ vmwareAlertRisk OBJECT-TYPE vmwareAlertEfficiency OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "Efficiency badge state." ::= { vmwareGenericAlertData 14 } @@ -189,7 +189,7 @@ vmwareAlertEfficiency OBJECT-TYPE vmwareAlertMetricName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "The textual metric name of the alert that was generated." ::= { vmwareGenericAlertData 15 } @@ -197,7 +197,7 @@ vmwareAlertMetricName OBJECT-TYPE vmwareAlertResourceKind OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "The textual object type of the alert that was generated." ::= { vmwareGenericAlertData 16 } @@ -205,7 +205,7 @@ vmwareAlertResourceKind OBJECT-TYPE vmwareAlertDefinitionName OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "Alert Definition Name." ::= { vmwareGenericAlertData 17 } @@ -213,7 +213,7 @@ vmwareAlertDefinitionName OBJECT-TYPE vmwareAlertDefinitionDesc OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "Alert Definition Description." ::= { vmwareGenericAlertData 18 } @@ -221,7 +221,7 @@ vmwareAlertDefinitionDesc OBJECT-TYPE vmwareAlertImpact OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS accessible-for-notify - STATUS current + STATUS obsolete DESCRIPTION "Alert Impact" ::= { vmwareGenericAlertData 19 } @@ -266,7 +266,7 @@ vmwareTrapKPIBreachActive NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Smart Alert that indicates a KPI Breach condition became active." @@ -288,7 +288,7 @@ vmwareTrapKPIBreachClear NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Smart Alert that indicates a KPI Breach condition became inactive." @@ -310,7 +310,7 @@ vmwareTrapKPIBreachChange NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Smart Alert that indicates a KPI Breach condition has changed one of its parameters' value." @@ -332,7 +332,7 @@ vmwareTrapKPIPredictionActive NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Smart Alert that predicts a KPI Breach condition (also know as 'Fingerprint') became active." @@ -354,7 +354,7 @@ vmwareTrapKPIPredictionClear NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Smart Alert that predicts a KPI Breach condition (also know as 'Fingerprint') became inactive." @@ -376,7 +376,7 @@ vmwareTrapKPIPredictionChange NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Smart Alert that predicts a KPI Breach condition (also know as 'Fingerprint') that experiences a change in one or more @@ -402,7 +402,7 @@ vmwareTrapAggregateAnomalyActive NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Smart Alert that indicates an Aggregate Anomaly condition became active." @@ -424,7 +424,7 @@ vmwareTrapAggregateAnomalyClear NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Smart Alert that indicates an Aggregate Anomaly condition became inactive." @@ -446,7 +446,7 @@ vmwareTrapKPIHTBreachActive NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Classic Alert that indicates a KPI HT Breach condition became active." @@ -468,7 +468,7 @@ vmwareTrapKPIHTBreachClear NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Classic Alert that indicates a KPI HT Breach condition became inactive." @@ -490,7 +490,7 @@ vmwareTrapKPIHTBreachChange NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Classic Alert that indicates a KPI HT Breach condition has changed one of its parameters' value." @@ -512,7 +512,7 @@ vmwareTrapNotificationActive NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Classic Alert that indicates a Notification condition became active." @@ -534,7 +534,7 @@ vmwareTrapNotificationClear NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Classic Alert that indicates a Notification condition became inactive." @@ -556,7 +556,7 @@ vmwareTrapNotificationChange NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Classic Alert that indicates a Notification condition has changed one of its parameters' value." @@ -578,7 +578,7 @@ vmwareTrapAbnormalityActive NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Classic Alert that indicates a Abnormality condition became active." @@ -601,7 +601,7 @@ vmwareTrapAbnormalityClear NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Classic Alert that indicates a Abnormality condition became inactive." @@ -623,7 +623,7 @@ vmwareTrapAbnormalityChange NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Classic Alert that indicates a Abnormality condition has changed one of its parameters' value." @@ -645,7 +645,7 @@ vmwareTrapWorkloadActive NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Health Alert that indicates a Workload condition became active." @@ -667,7 +667,7 @@ vmwareTrapWorkloadClear NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Health Alert that indicates a Workload condition became inactive." @@ -689,7 +689,7 @@ vmwareTrapWorkloadChange NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Health Alert that indicates a Workload condition has changed one of its parameters' value." @@ -711,7 +711,7 @@ vmwareTrapAnomalyActive NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Health Alert that indicates an Anomaly condition became active." @@ -733,7 +733,7 @@ vmwareTrapAnomalyClear NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Health Alert that indicates an Anomaly condition became inactive." @@ -755,7 +755,7 @@ vmwareTrapAnomalyChange NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Health Alert that indicates an Anomaly condition has changed one of its parameters' value." @@ -777,7 +777,7 @@ vmwareTrapFaultActive NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Health Alert that indicates a Fault condition became active." @@ -799,7 +799,7 @@ vmwareTrapFaultClear NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Health Alert that indicates a Fault condition became inactive." @@ -821,7 +821,7 @@ vmwareTrapFaultChange NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Health Alert that indicates a Fault condition has changed one of its parameters' value." @@ -843,7 +843,7 @@ vmwareTrapTimeRemainingActive NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Risk Alert that indicates a Time Remaining condition became active." @@ -865,7 +865,7 @@ vmwareTrapTimeRemainingClear NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Risk Alert that indicates a Time Remaining condition became inactive." @@ -887,7 +887,7 @@ vmwareTrapTimeRemainingChange NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Risk Alert that indicates a Time Remaining condition has changed one of its parameters' value." @@ -909,7 +909,7 @@ vmwareTrapCapacityRemainingActive NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Risk Alert that indicates a Capacity Remaining condition became active." @@ -931,7 +931,7 @@ vmwareTrapCapacityRemainingClear NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Risk Alert that indicates a Capacity Remaining condition became inactive." @@ -953,7 +953,7 @@ vmwareTrapCapacityRemainingChange NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Risk Alert that indicates a Capacity Remaining condition has changed one of its parameters' value." @@ -975,7 +975,7 @@ vmwareTrapStressActive NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Risk Alert that indicates a Stress condition became active." @@ -997,7 +997,7 @@ vmwareTrapStressClear NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Risk Alert that indicates a Stress condition became inactive." @@ -1019,7 +1019,7 @@ vmwareTrapStressChange NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Risk Alert that indicates a Stress condition has changed one of its parameters' value." @@ -1041,7 +1041,7 @@ vmwareTrapWasteActive NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Efficiency Alert that indicates a Waste condition became active." @@ -1063,7 +1063,7 @@ vmwareTrapWasteClear NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Efficiency Alert that indicates a Waste condition became inactive." @@ -1085,7 +1085,7 @@ vmwareTrapWasteChange NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Efficiency Alert that indicates a Waste condition has changed one of its parameters' value." @@ -1107,7 +1107,7 @@ vmwareTrapDensityActive NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Efficiency Alert that indicates a Density condition became active." @@ -1129,7 +1129,7 @@ vmwareTrapDensityClear NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Efficiency Alert that indicates a Density condition became inactive." @@ -1151,7 +1151,7 @@ vmwareTrapDensityChange NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Efficiency Alert that indicates a Density condition has changed one of its parameters' value." @@ -1173,7 +1173,7 @@ vmwareTrapDensityChange NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Risk Alert that indicates a Compliance condition became active." @@ -1195,7 +1195,7 @@ vmwareTrapDensityChange NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Risk Alert that indicates a Compliance condition became inactive." @@ -1217,7 +1217,7 @@ vmwareTrapComplianceChange NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Risk Alert that indicates a Compliance condition has changed one of its parameters' value." @@ -1245,7 +1245,7 @@ vmwareTrapProblemActive NOTIFICATION-TYPE vmwareAlertDefinitionDesc, vmwareAlertImpact } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Problem Alert that indicates a Abnormality condition became active." @@ -1273,7 +1273,7 @@ vmwareTrapProblemClear NOTIFICATION-TYPE vmwareAlertDefinitionDesc, vmwareAlertImpact } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Problem Alert that indicates a Abnormality condition became inactive." @@ -1301,7 +1301,7 @@ vmwareTrapProblemChange NOTIFICATION-TYPE vmwareAlertDefinitionDesc, vmwareAlertImpact } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Problem Alert that indicates a Abnormality condition has changed one of its parameters' value." @@ -1331,7 +1331,7 @@ vmwareTrapAliveComponentFailureActive NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing an Administrative Alert that indicates an vRealize Operations Component failure became active." @@ -1353,7 +1353,7 @@ vmwareTrapAliveComponentFailureClear NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing an Administrative Alert that indicates an vRealize Operations Component failure became inactive." @@ -1375,7 +1375,7 @@ vmwareTrapResourceDisconnectedActive NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing an Administrative Alert that indicates a resource has disconnected from vRealize Operations." @@ -1397,7 +1397,7 @@ vmwareTrapResourceDisconnectedClear NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing an Administrative Alert that indicates that a disconnected resource has re-connected to vRealize Operations." @@ -1421,7 +1421,7 @@ vmwareTrapConsolidatedAlertActive NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Consolidated Alert that aggregates similar alerts has become active" @@ -1443,7 +1443,7 @@ vmwareTrapConsolidatedAlertClear NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Consolidated Alert that aggregates similar alerts has become inactive" @@ -1465,7 +1465,7 @@ vmwareTrapConsolidatedAlertChange NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "A trap describing a Consolidated Alert that aggregates similar alerts has changed one of its parameters" @@ -1491,7 +1491,7 @@ vmwareTrapTest NOTIFICATION-TYPE vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS current + STATUS obsolete DESCRIPTION "Trap for testing purposes." ::= { vmwareAlertTrap 200 } @@ -1503,7 +1503,7 @@ vmwVCOPSMIBGroups OBJECT IDENTIFIER ::= { vmwVCOPSMIBConformance 2 } -- compliance statements vmwVCOPSMIBBasicCompliance MODULE-COMPLIANCE - STATUS deprecated + STATUS obsolete DESCRIPTION "The compliance statement for entities which implement VMWARE-VCOPS-EVENT-MIB." MODULE -- this module @@ -1526,7 +1526,7 @@ vmwVCOPSNotificationInfoGroup1 OBJECT-GROUP vmwareAlertMetricName, vmwareAlertResourceKind } - STATUS deprecated + STATUS obsolete DESCRIPTION "These objects provide details in vRealize Operations notifications." ::= { vmwVCOPSMIBGroups 2 } @@ -1586,13 +1586,13 @@ vmwVCOPSNotificationGroup1 NOTIFICATION-GROUP vmwareTrapResourceDisconnectedActive, vmwareTrapResourceDisconnectedClear } - STATUS deprecated + STATUS obsolete DESCRIPTION "Group of objects describing notifications (traps, informs)." ::= { vmwVCOPSMIBGroups 3 } vmwVCOPSMIBBasicCompliance2016 MODULE-COMPLIANCE - STATUS current + STATUS obsolete DESCRIPTION "Define which events apply to agents implementing VMWARE-VCOPS-EVENT-MIB." MODULE -- this module @@ -1622,7 +1622,7 @@ vmwVCOPSNotificationInfoGroup2 OBJECT-GROUP vmwareAlertDefinitionDesc, vmwareAlertImpact } - STATUS current + STATUS obsolete DESCRIPTION "These objects provide details in vRealize Operations notifications." ::= { vmwVCOPSMIBGroups 4 } @@ -1686,7 +1686,7 @@ vmwVCOPSNotificationGroup2 NOTIFICATION-GROUP vmwareTrapProblemClear, vmwareTrapProblemChange } - STATUS current + STATUS obsolete DESCRIPTION "Group of objects describing notifications (traps, informs) supported for this version of this mib modules." diff --git a/mibs/vmware/VMWARE-VRNI-AGENTCAP-MIB b/mibs/vmware/VMWARE-VRNI-AGENTCAP-MIB index 6d9b496303..d523099194 100644 --- a/mibs/vmware/VMWARE-VRNI-AGENTCAP-MIB +++ b/mibs/vmware/VMWARE-VRNI-AGENTCAP-MIB @@ -13,7 +13,7 @@ IMPORTS FROM SNMPv2-CONF; vmwVRNIAgentCapabilityMIB MODULE-IDENTITY - LAST-UPDATED "201710130000Z" + LAST-UPDATED "202005200000Z" ORGANIZATION "VMware, Inc" CONTACT-INFO "VMware, Inc @@ -24,7 +24,32 @@ vmwVRNIAgentCapabilityMIB MODULE-IDENTITY Web: http://kb.vmware.com/kb/1013445 " DESCRIPTION - "This module defines agent capabilities for deployed VRNI agents by release." + "This module defines agent capabilities for deployed VRNI agents by release. + It is compatible with vRNI v3.8 and onwards" + + REVISION "202005200000Z" + DESCRIPTION + "Notifications sent by VRNI as updated in 5.1 and 5.2 release" + + REVISION "201908190000Z" + DESCRIPTION + "Notifications sent by VRNI as updated in 5.0 release" + + REVISION "201906060000Z" + DESCRIPTION + "Notifications sent by VRNI as updated in 4.2 release" + + REVISION "201903220000Z" + DESCRIPTION + "Notifications sent by VRNI as updated in 4.1 release" + + REVISION "201812040000Z" + DESCRIPTION + "Notifications sent by VRNI as updated in 4.0 release" + + REVISION "201809120000Z" + DESCRIPTION + "Notifications sent by VRNI as updated in 3.9 release" REVISION "201710130000Z" DESCRIPTION @@ -48,6 +73,141 @@ vmwVRNIAgentCapabilityMIB MODULE-IDENTITY vmwVRNICapability OBJECT IDENTIFIER ::= { vmwVRNIAgentCapabilityMIB 10 } +vmwVRNIAgent2020v520 AGENT-CAPABILITIES + PRODUCT-RELEASE + "5.2.0" + STATUS current + DESCRIPTION + "Release 5.2.0 for VMware VRNI. + It describes all the notifications sent from this version of VRNI appliance." + REFERENCE + "http://www.vmware.com/products" + -- REVISION 202005200000Z Tenth Version + SUPPORTS VMWARE-VRNI-MIB + INCLUDES { vmwNetworkInsightNotificationInfoGroup3, + vmwNetworkInsightNotificationGroup1, + vmwNetworkInsightNotificationGroup2, + vmwNetworkInsightNotificationGroup3, + vmwNetworkInsightNotificationGroup4, + vmwNetworkInsightNotificationGroup5, + vmwNetworkInsightNotificationGroup6, + vmwNetworkInsightNotificationGroup7, + vmwNetworkInsightNotificationGroup8, + vmwNetworkInsightNotificationGroup9, + vmwNetworkInsightNotificationGroup10 + } + ::= { vmwVRNICapability 16 } + +vmwVRNIAgent2019v500 AGENT-CAPABILITIES + PRODUCT-RELEASE + "5.0.0" + STATUS current + DESCRIPTION + "Release 5.0.0 for VMware VRNI. + It describes all the notifications sent from this version of VRNI appliance." + REFERENCE + "http://www.vmware.com/products" + -- REVISION 201908190000Z Ninth Version + SUPPORTS VMWARE-VRNI-MIB + INCLUDES { vmwNetworkInsightNotificationInfoGroup3, + vmwNetworkInsightNotificationGroup1, + vmwNetworkInsightNotificationGroup2, + vmwNetworkInsightNotificationGroup3, + vmwNetworkInsightNotificationGroup4, + vmwNetworkInsightNotificationGroup5, + vmwNetworkInsightNotificationGroup6, + vmwNetworkInsightNotificationGroup7, + vmwNetworkInsightNotificationGroup8, + vmwNetworkInsightNotificationGroup9 + } + ::= { vmwVRNICapability 15 } + +vmwVRNIAgent2019v420 AGENT-CAPABILITIES + PRODUCT-RELEASE + "4.2.0" + STATUS current + DESCRIPTION + "Release 4.2.0 for VMware VRNI. + It describes all the notifications sent from this version of VRNI appliance." + REFERENCE + "http://www.vmware.com/products" + -- REVISION 201906060000Z Eighth Version + SUPPORTS VMWARE-VRNI-MIB + INCLUDES { vmwNetworkInsightNotificationInfoGroup3, + vmwNetworkInsightNotificationGroup1, + vmwNetworkInsightNotificationGroup2, + vmwNetworkInsightNotificationGroup3, + vmwNetworkInsightNotificationGroup4, + vmwNetworkInsightNotificationGroup5, + vmwNetworkInsightNotificationGroup6, + vmwNetworkInsightNotificationGroup7, + vmwNetworkInsightNotificationGroup8 + } + ::= { vmwVRNICapability 14 } + +vmwVRNIAgent2019v410 AGENT-CAPABILITIES + PRODUCT-RELEASE + "4.1.0" + STATUS current + DESCRIPTION + "Release 4.1.0 for VMware VRNI. + It describes all the notifications sent from this version of VRNI appliance." + REFERENCE + "http://www.vmware.com/products" + -- REVISION 201903220000Z Seventh Version + SUPPORTS VMWARE-VRNI-MIB + INCLUDES { vmwNetworkInsightNotificationInfoGroup3, + vmwNetworkInsightNotificationGroup1, + vmwNetworkInsightNotificationGroup2, + vmwNetworkInsightNotificationGroup3, + vmwNetworkInsightNotificationGroup4, + vmwNetworkInsightNotificationGroup5, + vmwNetworkInsightNotificationGroup6, + vmwNetworkInsightNotificationGroup7 + } + ::= { vmwVRNICapability 13 } + +vmwVRNIAgent2018v400 AGENT-CAPABILITIES + PRODUCT-RELEASE + "4.0.0" + STATUS current + DESCRIPTION + "Release 4.0.0 for VMware VRNI. + It describes all the notifications sent from this version of VRNI appliance." + REFERENCE + "http://www.vmware.com/products" + -- REVISION 201812120000Z Sixth Version + SUPPORTS VMWARE-VRNI-MIB + INCLUDES { vmwNetworkInsightNotificationInfoGroup3, + vmwNetworkInsightNotificationGroup1, + vmwNetworkInsightNotificationGroup2, + vmwNetworkInsightNotificationGroup3, + vmwNetworkInsightNotificationGroup4, + vmwNetworkInsightNotificationGroup5, + vmwNetworkInsightNotificationGroup6 + } + ::= { vmwVRNICapability 12 } + +vmwVRNIAgent2018v390 AGENT-CAPABILITIES + PRODUCT-RELEASE + "3.9.0" + STATUS current + DESCRIPTION + "Release 3.9.0 for VMware VRNI. + It describes all the notifications sent from the VRNI appliance." + REFERENCE + "http://www.vmware.com/products" + -- REVISION 201809120000Z Fifth Version + SUPPORTS VMWARE-VRNI-MIB + INCLUDES { vmwNetworkInsightNotificationInfoGroup3, + vmwNetworkInsightNotificationGroup1, + vmwNetworkInsightNotificationGroup2, + vmwNetworkInsightNotificationGroup3, + vmwNetworkInsightNotificationGroup4, + vmwNetworkInsightNotificationGroup5 + } + ::= { vmwVRNICapability 11 } + vmwVRNIAgent2016v350 AGENT-CAPABILITIES PRODUCT-RELEASE "3.5.0" diff --git a/mibs/vmware/VMWARE-VRNI-MIB b/mibs/vmware/VMWARE-VRNI-MIB index ba9893cc51..66817b4bae 100644 --- a/mibs/vmware/VMWARE-VRNI-MIB +++ b/mibs/vmware/VMWARE-VRNI-MIB @@ -1,5 +1,5 @@ -- ********************************************************** --- Copyright 2016-2017 VMware, Inc. All rights reserved. +-- Copyright 2016 - 2018 VMware, Inc. All rights reserved. -- ********************************************************** VMWARE-VRNI-MIB DEFINITIONS ::= BEGIN @@ -19,7 +19,7 @@ IMPORTS FROM VMWARE-TC-MIB; vmwNetworkInsightMIB MODULE-IDENTITY - LAST-UPDATED "201709050000Z" + LAST-UPDATED "202005200000Z" ORGANIZATION "VMware, Inc" CONTACT-INFO "VMware, Inc @@ -27,22 +27,68 @@ IMPORTS Palo Alto, CA 94304 Tel: 1-877-486-9273 or 650-427-5000 Fax: 650-427-5001 - Web: http://kb.vmware.com/kb/1013445 + Web: http://communities.vmware.com/community/developer/forums/managementapi " + DESCRIPTION - "This MIB module is for VMware vRealize Network Insight as described here: - https://www.vmware.com/support/pubs/vrealize-network-insight-pubs.html - " + "This MIB module is for VMware vRealize Network Insight as described here: + https://www.vmware.com/support/pubs/vrealize-network-insight-pubs.html + " + + REVISION "202005200000Z" + DESCRIPTION + "This is the tenth revision of VMware vRealize Network Insight Manager SNMP notifications. + It adds fifty two new notifications, see vmwNetworkInsightNotificationGroup10. + " + + REVISION "201908190000Z" + DESCRIPTION + "This is the ninth revision of VMware vRealize Network Insight Manager SNMP notifications. + It adds two new notifications, see vmwNetworkInsightNotificationGroup9. + " + + REVISION "201906060000Z" + DESCRIPTION + "This is the eighth revision of VMware vRealize Network Insight Manager SNMP notifications. + It adds two new notifications, see vmwNetworkInsightNotificationGroup8. + " + + REVISION "201903220000Z" + DESCRIPTION + "This is the seventh revision of VMware vRealize Network Insight Manager SNMP notifications. + It adds seventeen new notifications, see vmwNetworkInsightNotificationGroup7. + " + + REVISION "201811270000Z" + DESCRIPTION + "This is the sixth revision of VMware vRealize Network Insight Manager SNMP notifications. + It adds fourteen new notifications, see vmwNetworkInsightNotificationGroup6. + " + + REVISION "201809120000Z" + DESCRIPTION + "This is the fifth revision of VMware vRealize Network Insight Manager SNMP notifications. + This revision introduces below changes, some of which are non backward compatible. + a. All event notifications have their varbind contents changed + from : OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName} + to : OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + + b. Syntax changes for TC - VmwVrniSeverity + was { cleared(0), info(1), major(2) } + is now VmwVrniSeverity {Critical, Moderate, Warning, Info and CLEARED} + + c. Support for new events added, see vmwNetworkInsightNotificationGroup5 + " REVISION "201709050000Z" DESCRIPTION - "This is the fourth revsion of VMware vRealize Network Insight Manager SNMP notifications. + "This is the fourth revision of VMware vRealize Network Insight Manager SNMP notifications. It adds fourteen new notifications, see vmwNetworkInsightNotificationGroup4. " REVISION "201706010000Z" DESCRIPTION - "This is the third revsion of VMware vRealize Network Insight Manager SNMP notifications. + "This is the third revision of VMware vRealize Network Insight Manager SNMP notifications. This version added nineteen new notifications, see vmwNetworkInsightNotificationGroup3 for complete listing." @@ -58,6 +104,7 @@ IMPORTS "This is the first revision of VMware vRealize Network Insight Manager SNMP notifications." ::= { vmwNetworkInsight 1 } + vmwVRNIEvents OBJECT-IDENTITY STATUS current DESCRIPTION @@ -74,22 +121,25 @@ vmwVRNIData OBJECT-IDENTITY -- Type definitions -- ********************************************************** -VmwVrniSeverity ::= TEXTUAL-CONVENTION - STATUS current + VmwVrniSeverity ::= TEXTUAL-CONVENTION + DISPLAY-HINT "255t" + STATUS current DESCRIPTION - "Event Severity - For Problems, Major - Opens and alarms, Cleared Closes it - For Notifications - All are Info + "Represents Event Severity, the values returned by TC are + Critical - All events which are critical in nature towards overall health of environment, could be show stoppers if not fixed + Moderate - Represents moderate severity, part of functionality could get affected + Warning - Event which may not represent immediate issue but could soon become one if not addressed + Info - Informational notifications + CLEARED - Event was closed by system. " - SYNTAX INTEGER { cleared(0), info(1), major(2) } - + SYNTAX OCTET STRING (SIZE (0..255)) -- ********************************************************** -- Notifications by an agent that implements this mib module -- ********************************************************** vmwSnmpTrapsAreConfigured NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Initial trap to notify receiver that vRNI is now configured to send SNMP traps" @@ -97,1153 +147,3164 @@ vmwSnmpTrapsAreConfigured NOTIFICATION-TYPE vmwSnmpTrapsAreDisabled NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Trap to notify receiver that vRNI is no longer configured to send SNMP traps" ::= { vmwVRNIEvents 102} + vmwTestTrap NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Test Trap" ::= { vmwVRNIEvents 103} + vmwEntityDiscoveryChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Discovery Event" ::= { vmwVRNIEvents 20001} vmwEntityPropertiesChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Property Change Event" ::= { vmwVRNIEvents 20002} vmwFirewallNotInstalledOnHostEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Firewall Not Installed On Host Event" ::= { vmwVRNIEvents 20003} vmwHostWithStaleFirewallRulesEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Host With Stale Firewall Rules Event" ::= { vmwVRNIEvents 20004} vmwIpAddressChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Ip Address Change" ::= { vmwVRNIEvents 20005} vmwL2GatewayAnomalyEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "L2 Gateway Anomaly Event" ::= { vmwVRNIEvents 20006} vmwL2NetworkAddressAnomalyEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "L2 Network Address Anomaly Event" ::= { vmwVRNIEvents 20007} vmwL2NetworkDiameterExceededEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "L2 Network Diameter Exceeded Event" ::= { vmwVRNIEvents 20008} vmwL2NetworkUplinkMissingEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "L2 Network Uplink Missing Event" ::= { vmwVRNIEvents 20009} vmwL2NetworkWithNoVMsEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "L2 Network With No VMs Event" ::= { vmwVRNIEvents 20010} vmwLayer2NetworkDiameterChangedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Layer2 Network Diameter Changed Event" ::= { vmwVRNIEvents 20011} vmwMTUMismatchEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "MTU Mismatch Event" ::= { vmwVRNIEvents 20012} vmwNetworkIsolationEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Network Isolation Event" ::= { vmwVRNIEvents 20013} vmwNoPathEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "No Path Event" ::= { vmwVRNIEvents 20014} vmwSpoofguardDisabledEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Spoofguard Disabled Event" ::= { vmwVRNIEvents 20015} vmwVMotionEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "VMotion Event" ::= { vmwVRNIEvents 20018} vmwVMWithDisconnectedVnicsEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "VM With Disconnected Vnics Event" ::= { vmwVRNIEvents 20019} vmwVMWithMulipleVnicsOnDifferentVxlansEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "VM With Multiple Vnics On Different Vxlans Event" ::= { vmwVRNIEvents 20020} vmwVMWithMulipleVnicsOnSameL2Event NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "VM With Multiple Vnics On Same L2 Event" ::= { vmwVRNIEvents 20021} vmwVMWithNoIpAddressEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "VM With No Ip Address Event" ::= { vmwVRNIEvents 20022} vmwVTEPMissingEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "VTEP Missing Event" ::= { vmwVRNIEvents 20023} vmwL2Event NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "L2 Event" ::= { vmwVRNIEvents 20024} vmwMembershipChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Membership Change" ::= { vmwVRNIEvents 20025} vmwSecurityGroupMembershipChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Security Group Membership Change" ::= { vmwVRNIEvents 20026} vmwFirewallRuleMembershipChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Firewall Rule Membership Change" ::= { vmwVRNIEvents 20027} vmwVlanMembershipChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Vlan Membership Change" ::= { vmwVRNIEvents 20028} vmwVxlanMembershipChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Vxlan Membership Change" ::= { vmwVRNIEvents 20029} vmwDeleteChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Delete Event" ::= { vmwVRNIEvents 20030} vmwVtepFailedPingEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "VTEP Ping Failure Event" ::= { vmwVRNIEvents 20031} vmwEmptySearchStreamChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Search with no results" ::= { vmwVRNIEvents 20034} vmwSearchStreamMembershipChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Search results changed" ::= { vmwVRNIEvents 20035} vmwEmptySearchStreamProblemEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Search with no results (Problem)" ::= { vmwVRNIEvents 20036} vmwSearchStreamMembershipProblemEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Search results changed (Problem)" ::= { vmwVRNIEvents 20037} vmwOspfConfigurationMismatchEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "OSPF Mismatch Event" ::= { vmwVRNIEvents 20038} vmwServiceVMNotHealthyEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Service VM Not Healthy Event" ::= { vmwVRNIEvents 20039} vmwServiceVMNotPoweredOnEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Service VM Not Powered On Event" ::= { vmwVRNIEvents 20040} vmwServiceVMHighCPUUsageEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Service VM High CPU Usage Event" ::= { vmwVRNIEvents 20041} vmwServiceVMHighMemoryUsageEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Service VM High Memory Usage Event" ::= { vmwVRNIEvents 20042} vmwServiceVMHighDiskUsageEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Service VM High Disk Usage Event" ::= { vmwVRNIEvents 20043} vmwIPSetPropertiesChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "IPSet Change" ::= { vmwVRNIEvents 20050} vmwFirewallRulePropertiesChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Firewall Rule Change" ::= { vmwVRNIEvents 20051} vmwSecurityGroupPropertiesChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Security Group Change" ::= { vmwVRNIEvents 20052} vmwIPSetMembershipChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "IPSet Membership Change" ::= { vmwVRNIEvents 20053} vmwFirewallRuleMaskEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Firewall Rule Masked Event" ::= { vmwVRNIEvents 20054} vmwSecurityMembershipChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Security Membership Change" ::= { vmwVRNIEvents 20056} vmwSecurityTagPropertiesChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Security Tag Change" ::= { vmwVRNIEvents 20057} vmwSecurityTagMembershipChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Security Tag Membership Change" ::= { vmwVRNIEvents 20058} vmwHostDatastoreChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Host datastores changed" ::= { vmwVRNIEvents 20059} vmwVMDatastoreChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "VM datastores changed" ::= { vmwVRNIEvents 20060} vmwVMSnapshotChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "VM snapshot changed" ::= { vmwVRNIEvents 20061} vmwVMVirtualDiskChangeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Virtual disk migrated" ::= { vmwVRNIEvents 20062} vmwIPSetDefinitionMismatchEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "IPSET Definition Mismatch Event" ::= { vmwVRNIEvents 20063} vmwSegmentMismatchEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Segment Mismatch Event" ::= { vmwVRNIEvents 20064} vmwVtepEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Vtep Event" ::= { vmwVRNIEvents 20065} vmwVtepConfigurationFaultEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Vtep Configuration Fault Event" ::= { vmwVRNIEvents 20066} vmwVtepSubnetMismatchEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Vtep Subnet Mismatch Event" ::= { vmwVRNIEvents 20068} vmwVtepCountMismatchEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Vtep Count Mismatch Event" ::= { vmwVRNIEvents 20069} vmwDLRNetworksNotReachableEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "DLR Routing event" ::= { vmwVRNIEvents 20067} vmwEdgeNetworksNotReachableEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Edge Routing event" ::= { vmwVRNIEvents 20070} +vmwNiInfraChangeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NI Infra Change" + ::= { vmwVRNIEvents 20089} + +vmwDataSourceEnabledChangeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Data Source Enabled" + ::= { vmwVRNIEvents 20090} + +vmwDataSourceDisabledChangeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Data Source Disabled" + ::= { vmwVRNIEvents 20091} + +vmwDataSourceCreatedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Data Source Created" + ::= { vmwVRNIEvents 20092} + +vmwPlatformCpuCoreChangeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Platform CPU Change Event" + ::= { vmwVRNIEvents 20093} + +vmwPlatformDiskChangeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Platform Disk Change Event" + ::= { vmwVRNIEvents 20094} + +vmwPlatformMemoryChangeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Platform Memory Change Event" + ::= { vmwVRNIEvents 20095} + +vmwPlatformRebootedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Platform Reboot Change Event" + ::= { vmwVRNIEvents 20096} + +vmwProxyCpuCoreChangeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Collector CPU Change Event" + ::= { vmwVRNIEvents 20097} + +vmwProxyDiskChangeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Collector Disk Change Event" + ::= { vmwVRNIEvents 20098} + +vmwProxyMemoryChangeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Collector Memory Change Event" + ::= { vmwVRNIEvents 20099} + +vmwProxyRebootedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Collector Reboot Change Event" + ::= { vmwVRNIEvents 20100} + +vmwNIClusterChangeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Cluster Change Event" + ::= { vmwVRNIEvents 20101} + +vmwNISystemProxyChangeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "System Proxy Change Event" + ::= { vmwVRNIEvents 20102} + +vmwNIClusterCreateEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Cluster Create Event" + ::= { vmwVRNIEvents 20103} + vmwThresholdExceededEventCpuReady NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Threshold Exceeded Cpu Ready" ::= { vmwVRNIEvents 30001} vmwThresholdExceededEventCpuCoStop NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Threshold Exceeded Cpu Co Stop" ::= { vmwVRNIEvents 30002} vmwThresholdExceededEventDiskCommandAbortRule NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Threshold Exceeded Disk Command Abort Rule" ::= { vmwVRNIEvents 30003} vmwThresholdExceededEventIODeviceLatencyRule NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Threshold Exceeded IO Device Latency Rule" ::= { vmwVRNIEvents 30004} vmwThresholdExceededEventIOKernelLatencyRule NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Threshold Exceeded IO Kernel Latency Rule" ::= { vmwVRNIEvents 30005} vmwThresholdExceededEventMemorySwapInRule NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Threshold Exceeded Memory Swap In Rule" ::= { vmwVRNIEvents 30006} vmwThresholdExceededEventMemorySwapOutRule NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Threshold Exceeded Memory Swap Out Rule" ::= { vmwVRNIEvents 30007} vmwThresholdExceededEventNetworkRxDropRule NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Threshold Exceeded Memory Rx Drop Rule" ::= { vmwVRNIEvents 30008} vmwThresholdExceededEventNetworkTxDropRule NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Threshold Exceeded Memory Tx Drop Rule" ::= { vmwVRNIEvents 30009} +vmwAWSRegionSGLimitEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "AWS Region Security Group count near threshold." + ::= { vmwVRNIEvents 30010} + +vmwAWSVPCSGLimitEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "AWS VPC Security Group count near threshold." + ::= { vmwVRNIEvents 30011} + +vmwAWSSGInboundRuleLimitEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "AWS Security Group Inbound Rule count near threshold." + ::= { vmwVRNIEvents 30012} + +vmwAWSSGOutboundRuleLimitEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "AWS Security Group Outbound Rule count near threshold." + ::= { vmwVRNIEvents 30013} + +vmwAWSInterfaceSGLimitEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "AWS VPC Security Group count near threshold." + ::= { vmwVRNIEvents 30014} + vmwPacketDropEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Packet Drop Event" ::= { vmwVRNIEvents 30100} vmwSwitchPortPacketDropEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Switch Port Packet Drop" ::= { vmwVRNIEvents 30101} vmwRouterInterfacePacketDropEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Router Interface Packet Drop" ::= { vmwVRNIEvents 30102} vmwVnicPacketDropEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Vnic Packet Drop" ::= { vmwVRNIEvents 30103} vmwVTEPUnderlayPacketDropEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "VTEP Underlay Packet Drop" ::= { vmwVRNIEvents 30104} vmwPnicUnderlyingSwitchPortPacketDropEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "PNIC Underlying Switch Port Packet Drop" ::= { vmwVRNIEvents 30105} vmwDevicePacketDropEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Device Packet Drop" ::= { vmwVRNIEvents 30106} vmwThresholdExceededEventDatastoreFreeSpaceWarning NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "ThresholdExceededEventDatastoreFreeSpaceWarning" ::= { vmwVRNIEvents 30203} vmwThresholdExceededEventDatastoreFreeSpaceCritical NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "ThresholdExceededEventDatastoreFreeSpaceCritical" ::= { vmwVRNIEvents 30204} vmwThresholdExceededEventDatastoreReadLatency NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "ThresholdExceededEventDatastoreReadLatency" ::= { vmwVRNIEvents 30205} vmwThresholdExceededEventDatastoreWriteLatency NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "ThresholdExceededEventDatastoreWriteLatency" ::= { vmwVRNIEvents 30206} vmwDistributedFirewallApplyHostEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Distributed Firewall Apply Host Event" ::= { vmwVRNIEvents 35001} vmwDistributedFirewallApplyVMEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Distributed Firewall Apply VM Event" ::= { vmwVRNIEvents 35002} vmwNsxEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION - "Nsx Event" + "NSX Event" ::= { vmwVRNIEvents 35003} vmwFeatureImpactedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Feature Impacted Event" ::= { vmwVRNIEvents 35004} vmwClusterFeatureVersionMismatchEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Cluster Feature Mismatch Event" ::= { vmwVRNIEvents 36022} vmwHostFeatureVersionMismatchEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Host Feature Mismatch Event" ::= { vmwVRNIEvents 36023} vmwFeatureVersionMismatchEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Feature Version Mismatch Event" ::= { vmwVRNIEvents 36024} vmwHostFeatureEnabledMismatchEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Feature Enabled Mismatch Event" ::= { vmwVRNIEvents 36025} vmwHostFeatureInstalledMismatchEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Feature Installed Mismatch Event" ::= { vmwVRNIEvents 36026} vmwHostVtepNotFoundEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Host Vtep Not Found Event" ::= { vmwVRNIEvents 36027} vmwHostVtepDisconnectedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Host Vtep Disconnected Event" ::= { vmwVRNIEvents 36028} vmwHostVtepEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Host Vtep Event" ::= { vmwVRNIEvents 36029} vmwClusterHostsVtepMTUMismatchEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Host Vtep Mtu Mismatch Event" ::= { vmwVRNIEvents 36030} vmwFeatureUnhealthyEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Feature Health Event" ::= { vmwVRNIEvents 36031} vmwEdgeHANotConfiguredEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "NSX Edge High Availability is not enabled Event" ::= { vmwVRNIEvents 36032} vmwEdgeInterfacesDownEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "One or More NSX Edge Interfaces are down Event" ::= { vmwVRNIEvents 36033} vmwModuleUnhealthyEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Module Unhealthy Event" ::= { vmwVRNIEvents 36041} vmwModuleNotLoadedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Module Not Loaded Event" ::= { vmwVRNIEvents 36042} vmwModuleNetworkConnectionFailureEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Module Network Connection Failure Event" ::= { vmwVRNIEvents 36043} vmwHostNetworkControlPlaneMismatchEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Control Plane Network Mismatch Event" ::= { vmwVRNIEvents 36044} vmwHostNetworkControlPlaneConnectionFailureEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Control Plane Network Connection Failure Event" ::= { vmwVRNIEvents 36045} vmwHostNetworkControlPlaneNotSyncedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Host Control Plane Sync Failure Event" ::= { vmwVRNIEvents 36046} vmwNSXControllerClusterMajorityEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "NSX Controller Cluster Majority Event" ::= { vmwVRNIEvents 36047} vmwNSXControllersVMOnSameHostEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "NSX Controllers VM On Same Host Event" ::= { vmwVRNIEvents 36048} vmwVxLanRangeExhaustEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Vxlan range exhaust Event" ::= { vmwVRNIEvents 36049} vmwNSXFirewallDefaultAllowAllRulesEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "NSX Firewall Allow All Rules Event" ::= { vmwVRNIEvents 36050} vmwLogicalRouterNoUplinkEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION - "Logical Router does not have an uplink interface configured Event" + "The NSX DLR is not configured with default route and may prevent external communication. + Check if the router configuration is only for routing between internal networks, or if external access is required. If external access is required, then configure an uplink interface on the NSX distributed logical router. + For more details about this event, please log into vRNI, navigate to Settings -> Events" ::= { vmwVRNIEvents 36051} vmwEdgeNotHAEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "NSX Edge not Highly Available Event" ::= { vmwVRNIEvents 36052} vmwEdgeNotDeployedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "NSX Edge not deployed Event" ::= { vmwVRNIEvents 36053} vmwEcmpIsEnabledAndStatefulServicesAreUpEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "NSX Edge Running with both ECMP and Stateful Edge Services Event" ::= { vmwVRNIEvents 36054} vmwLogicalRouterDeployedOnEcmpEdgeHostEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Logical Router and ECMP Edge on Same Host Event" ::= { vmwVRNIEvents 36055} vmwEdgeMissingInterfaceOSPFAreaMappingEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "NSX Edge Interface to OSPF Area Mapping Missing Event" ::= { vmwVRNIEvents 36056} vmwOspfInsecureAuthRouterEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "One or more OSPF areas on the NSX Edge are using insecure authentication Event" ::= { vmwVRNIEvents 36057} vmwNSXControllersDeployedCountEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "NSX Controller count Event" ::= { vmwVRNIEvents 36058} vmwNSXControllerNotActiveCountEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "NSX Controller Not Active Event" ::= { vmwVRNIEvents 36059} vmwNSXControllerEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION - "Nsx Controller Event" + "NSX Controller Event" ::= { vmwVRNIEvents 36060} vmwNSXEcmpEdgeDownEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "One or more NSX Edges in the ECMP Cluster are currently down" ::= { vmwVRNIEvents 36061} vmwNSXMajorityEcmpEdgesDownEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "The majority of NSX Edges in the ECMP Cluster are currently down" ::= { vmwVRNIEvents 36062} vmwNSXAllEcmpEdgesDownEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "All NSX Edges in the ECMP Cluster are currently down" ::= { vmwVRNIEvents 36063} vmwNSXEdgeMtuMismatchEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "The MTU configured on one or more interfaces on the Edge does not match the MTU on the next hop router" ::= { vmwVRNIEvents 36064} vmwNSXEdgeSplitBrainEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Both VMs of Edge HA are in active state" ::= { vmwVRNIEvents 36065} +vmwVirtualDistributedRoutingEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "VDR Port Unset Event" + ::= { vmwVRNIEvents 36066} + vmwNSXComponentEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "NSX Service not running event" ::= { vmwVRNIEvents 35221} vmwNSXBackupEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "NSX Backup not configured" ::= { vmwVRNIEvents 35222} vmwNSXBackupAuditLogExcludedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Audit Log excluded from NSX Backup" ::= { vmwVRNIEvents 35223} vmwNSXUnsecureBackupEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "NSX Backups not using secure FTP" ::= { vmwVRNIEvents 35224} vmwNSXBackupSystemEventsExcludedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "System Event excluded from NSX Backup" ::= { vmwVRNIEvents 35225} vmwNSXBackupNotScheduledEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Scheduled backups are not enabled" ::= { vmwVRNIEvents 35226} vmwNSXBackupNotRecordedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "No backup of the environment has been recorded" ::= { vmwVRNIEvents 35227} vmwNSXNtpServerEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "NTP Server not configured" ::= { vmwVRNIEvents 35228} vmwNSXSysLogServerEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Syslog Server not configured" ::= { vmwVRNIEvents 35229} vmwControllerSysLogServerEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Syslog Server not configured" ::= { vmwVRNIEvents 35230} vmwNSXIpV6EnabledEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "IPv6 is enabled for NSX Manager" ::= { vmwVRNIEvents 35231} vmwNSXOspfNeighborDownEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "One or more OSPF Neighbors down" ::= { vmwVRNIEvents 35232} vmwGenericNSXSystemEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION - "NSX System Events (Warning)" + "NSX System Event (Warning)" ::= { vmwVRNIEvents 70000} vmwOtherCriticalNSXEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION - "NSX System Events (Critical)" + "NSX System Event (Critical)" ::= { vmwVRNIEvents 71000} vmwFilterConfigApplyOnHostFailedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Filter Config Apply On Host Failed Event" ::= { vmwVRNIEvents 70001} vmwRulesetLoadOnHostFailedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Ruleset Load On Host Failed Event" ::= { vmwVRNIEvents 70002} vmwConfigUpdateOnHostFailedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Config Update On Host Failed Event" ::= { vmwVRNIEvents 70003} vmwSpoofguardConfigUpdateOnHostFailedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Spoofguard Config Update On Host Failed Event" ::= { vmwVRNIEvents 70004} vmwApplyRuleToVnicFailedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Apply Rule To Vnic Failed Event" ::= { vmwVRNIEvents 70005} vmwContainerConfigUpdateOnVnicFailedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Container Config Update On Vnic Failed Event" ::= { vmwVRNIEvents 70006} vmwSpoofguardApplyToVnicFailedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Spoofguard Apply To Vnic Failed Event" ::= { vmwVRNIEvents 70007} vmwHostMessagingConfigurationFailedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Host Messaging Configuration Failed Event" ::= { vmwVRNIEvents 70008} vmwHostMessagingConnectionReconfigurationFailedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Host Messaging Connection Reconfiguration Failed Event" ::= { vmwVRNIEvents 70009} vmwHostMessagingConfigurationFailedNotificationSkippedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Host Messaging Configuration Failed Notification Skipped Event" ::= { vmwVRNIEvents 70010} vmwHostMessagingInfrastructureDownEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Host Messaging Infrastructure Down Event" ::= { vmwVRNIEvents 70011} vmwEdgeVMNotRespondingEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Edge VM Responding Event" ::= { vmwVRNIEvents 70012} vmwEdgeUnhealthyEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Edge Health Event" ::= { vmwVRNIEvents 70013} vmwEdgeVMCommunicationFailureEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Edge communication failure Event" ::= { vmwVRNIEvents 70014} vmwNSXEdgeEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION - "Nsx Edge Event" + "NSX Edge Event" ::= { vmwVRNIEvents 70015} vmwPanEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Palo Alto Event" ::= { vmwVRNIEvents 80000} vmwPanNsxNotInRegisteredStateEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION - "Palo Alto Nsx Registration Event" + "Palo Alto NSX Registration Event" ::= { vmwVRNIEvents 80001} vmwPanNsxDynamicUpdateDelayedEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION - "Palo Alto Nsx Dynamic Update Event" + "Palo Alto NSX Dynamic Update Event" ::= { vmwVRNIEvents 80002} vmwPanDeviceInDisconnectedStateEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Palo Alto Device Disconnect Event" ::= { vmwVRNIEvents 80003} vmwPanNsxServiceApplianceViewMismatchEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Palo Alto Service Device Mismatch Event" ::= { vmwVRNIEvents 80004} vmwPanNsxFabricAgentNotFoundOnHostEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION - "Nsx Fabric Agent Not Found Event" + "NSX Fabric Agent Not Found Event" ::= { vmwVRNIEvents 80005} vmwPanNsxServiceVMNotFoundOnHostEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Palo Alto Service VM Not Found Event" ::= { vmwVRNIEvents 80006} vmwCheckpointEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Check Point Event" ::= { vmwVRNIEvents 80100} vmwCheckpointNsxFabricAgentNotFoundOnHostEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION - "Check Point Nsx Fabric Agent Not Found Event" + "Check Point NSX Fabric Agent Not Found Event" ::= { vmwVRNIEvents 80102} vmwCheckpointNsxServiceVMNotFoundOnHostEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Check Point Service VM Not Found Event" ::= { vmwVRNIEvents 80103} vmwCheckpointGatewaySicStatusNotCommunicatingEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Check Point Gateway Sic Status Not Communicating Event" ::= { vmwVRNIEvents 80104} vmwCheckpointNsxServiceApplianceViewMismatchEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Check Point Service VM Mismatch Event" ::= { vmwVRNIEvents 80105} vmwCriticalHostNotAccessibleEvent NOTIFICATION-TYPE - OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName } + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } STATUS current DESCRIPTION "Host with VMs running critical services is not accessible" ::= { vmwVRNIEvents 40001} +vmwIndexerLagEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Index Lag Event" + ::= { vmwVRNIEvents 80501} + +vmwIPFIXFlowDPPausedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "IPFIX Flow Data Provider Paused Event" + ::= { vmwVRNIEvents 80502} + +vmwGridProcessingStoppedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Grid Processing Stopped Event" + ::= { vmwVRNIEvents 80503} + +vmwUnableToSendEmailsEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Unable to Send Emails Event" + ::= { vmwVRNIEvents 80504} + +vmwSMTPNotConfiguredEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "SMPT Not Configured Event" + ::= { vmwVRNIEvents 80505} + +vmwSNMPNotConfiguredEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "SNMP Not Configured Event" + ::= { vmwVRNIEvents 80506} + +vmwReindexingInProgressEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Redindexing In Process Event" + ::= { vmwVRNIEvents 80507} + +vmwNodesVersionMismatchEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Node Version Mismatch Event" + ::= { vmwVRNIEvents 80508} + +vmwNotAllServicesRunningEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Not All Services Running Event" + ::= { vmwVRNIEvents 80509} + +vmwNotAllServicesHealthyEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Not All Services Healthy Event" + ::= { vmwVRNIEvents 80510} + +vmwExpandPartitionFailedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Expand Partition Failed Event" + ::= { vmwVRNIEvents 80511} + +vmwDiskCleanupFailedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Disk Cleanup Failed Event" + ::= { vmwVRNIEvents 80512} + +vmwVaccumFailedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Vacuum Failed Event" + ::= { vmwVRNIEvents 80513} + +vmwConfigStoreCleanupFailedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Config Store Cleanup Failed Event" + ::= { vmwVRNIEvents 80514} + +vmwHBaseRetentionToolFailedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "HBASE Retention Tool Failed Event" + ::= { vmwVRNIEvents 80515} + +vmwMetricStoreUpdaterFailedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Metric Store Updater Failed Event" + ::= { vmwVRNIEvents 80516} + +vmwCollectorLagEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Collecter Lag Event" + ::= { vmwVRNIEvents 80517} + +vmwCollectionLagEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Collection Lag Event" + ::= { vmwVRNIEvents 80518} + +vmwGridProcessingLagEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Grid Processing Lag Event" + ::= { vmwVRNIEvents 80519} + +vmwConnectionErrorEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Connection Error Event" + ::= { vmwVRNIEvents 80520} + +vmwNodeNotActiveEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Node Not Active Event" + ::= { vmwVRNIEvents 80521} + +vmwHighDiskUtilizationEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "High Disk Utilization Event" + ::= { vmwVRNIEvents 80522} + +vmwIndexingAbortedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Indexing Aborted Event" + ::= { vmwVRNIEvents 80523} + +vmwUpgradeFailedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Upgrade Failed Event" + ::= { vmwVRNIEvents 80524} + +vmwFlowProcessingSuspendedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Flow Processing Suspended Event" + ::= { vmwVRNIEvents 80525} + +vmwVCNotOnSameProxyEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "VC_NOT_ON_SAME_PROXY_EVENT" + ::= { vmwVRNIEvents 80643} + +vmwNoDVSAvailableEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NO_DVS_AVAILABLE_EVENT" + ::= { vmwVRNIEvents 80642} + +vmwUnknownInfobloxVersionEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Infoblox version cannot be determined" + ::= { vmwVRNIEvents 80641} + +vmwUnsupportedInfobloxVersionEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "The version of Infoblox is not supported" + ::= { vmwVRNIEvents 80640} + +vmwIncorrectInfobloxCredentialEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Invalid credentials or insufficient privileges" + ::= { vmwVRNIEvents 80639} + +vmwInfobloxRecordLimitExceededEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "The number of A records fetched from Infoblox exceeds the current limit" + ::= { vmwVRNIEvents 80638} + +vmwWebhookNotRunningEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "WEBHOOK_NOT_RUNNING_EVENT" + ::= { vmwVRNIEvents 80637} + +vmwIncorrectWebhookConfiguredOnAlertEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "INCORRECT_WEBHOOK_CONFIGURED_ON_ALERT_EVENT" + ::= { vmwVRNIEvents 80636} + +vmwWebhookNotEnabledOnAlertEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "WEBHOOK_NOT_ENABLED_ON_ALERT_EVENT" + ::= { vmwVRNIEvents 80635} + +vmwVRNIContentPackNotInstalledEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "vRNI_CONTENT_PACK_NOT_INSTALLED_EVENT" + ::= { vmwVRNIEvents 80634} + +vmwUnsupportedVRNIContentPackVersionEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "UNSUPPORTED_vRNI_CONTENT_PACK_VERSION_EVENT" + ::= { vmwVRNIEvents 80633} + +vmwUnsupportedLogInsightVersionEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "UNSUPPORTED_LOG_INSIGHT_VERSION_EVENT" + ::= { vmwVRNIEvents 80632} + +vmwComputeManagersNotAddedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "COMPUTE_MANAGERS_NOT_ADDED_EVENT" + ::= { vmwVRNIEvents 80631} + +vmwComputeManagersNotFoundEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "COMPUTE_MANAGERS_NOT_FOUND_EVENT" + ::= { vmwVRNIEvents 80630} + +vmwUnsupportedNSXTVersionEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "UNSUPPORTED_NSXT_VERSION_EVENT" + ::= { vmwVRNIEvents 80629} + +vmwNotEmptyNodeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NOT_EMPTY_NODE_EVENT" + ::= { vmwVRNIEvents 80628} + +vmwFlowPhysicalNodeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "FLOW_PHYSICAL_NODE_EVENT" + ::= { vmwVRNIEvents 80627} + +vmwFlowCollectionErrorEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "FLOW_COLLECTION_ERROR_EVENT" + ::= { vmwVRNIEvents 8061313} + +vmwAWSThrottlingExceptionEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "AWS_THROTTLING_EXCEPTION_EVENT" + ::= { vmwVRNIEvents 8061314} + +vmwAWSFlowLogAccessDeniedExceptionEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "AWS_FLOW_LOG_ACCESS_DENIED_EXCEPTION_EVENT" + ::= { vmwVRNIEvents 8061315} + +vmwNSXIPFIXStatusMismatchEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX_IPFIX_STATUS_MISMATCH_EVENT" + ::= { vmwVRNIEvents 80626} + +vmwNumVMsOrHostsNotFoundEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NUM_VMS_OR_HOSTS_NOT_FOUND_EVENT" + ::= { vmwVRNIEvents 80625} + +vmwUnsupportedNSXVersionEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "UNSUPPORTED_NSX_VERSION_EVENT" + ::= { vmwVRNIEvents 806100018} + +vmwPwdAuthModeDisabledAristaEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "PWD_AUTH_MODE_DISABLED_ARISTA_EVENT" + ::= { vmwVRNIEvents 806100012} + +vmwHostnameResolutionErrorEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "HOSTNAME_RESOLUTION_ERROR_EVENT" + ::= { vmwVRNIEvents 80624} + +vmwPrimaryNSXNotAddedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "PRIMARY_NSX_NOT_ADDED_EVENT" + ::= { vmwVRNIEvents 80623} + +vmwDataProviderNotRunningEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "DATA_PROVIDER_NOT_RUNNING_EVENT" + ::= { vmwVRNIEvents 80622} + +vmwInvalidResponseFromDatasourceEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "INVALID_RESPONSE_FROM_DATASOURCE_EVENT" + ::= { vmwVRNIEvents 80621} + +vmwHostNotReachableEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "HOST_NOT_REACHABLE_EVENT" + ::= { vmwVRNIEvents 80620} + +vmwNSXControllerNotFoundEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX_CONTROLLER_NOT_FOUND_EVENT" + ::= { vmwVRNIEvents 80619} + +vmwUnexpectedDSTypeOrVersionEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "UNEXPECTED_DS_TYPE_OR_VERSION_EVENT" + ::= { vmwVRNIEvents 80618} + +vmwWarnConfigEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "WARN_CONFIG_EVENT" + ::= { vmwVRNIEvents 80617} + +vmwInvalidConfigEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "INVALID_CONFIG_EVENT" + ::= { vmwVRNIEvents 80616} + +vmwNotFoundEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NOT_FOUND_EVENT" + ::= { vmwVRNIEvents 80614} + +vmwInsufficientPrivilegesEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "INSUFFICIENT_PRIVILEGES_EVENT" + ::= { vmwVRNIEvents 80613} + +vmwPwdAuthModeDisabledEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "PWD_AUTH_MODE_DISABLED_EVENT" + ::= { vmwVRNIEvents 80612} + +vmwFailedCredsEncryptEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "FAILED_CREDS_ENCRYPT_EVENT" + ::= { vmwVRNIEvents 80611} + +vmwSNMPConnectionInvalidEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "SNMP_CONNECTION_INVALID_EVENT" + ::= { vmwVRNIEvents 80609} + +vmwUnknownHostEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "UNKNOWN_HOST_EVENT" + ::= { vmwVRNIEvents 80608} + +vmwInvalidCredentialsEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "INVALID_CREDENTIALS_EVENT" + ::= { vmwVRNIEvents 80606} + +vmwIncorrectConnectionStringEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "INCORRECT_CONNECTION_STRING_EVENT" + ::= { vmwVRNIEvents 80605} + +vmwConnectionRefusedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "CONNECTION_REFUSED_EVENT" + ::= { vmwVRNIEvents 80603} + +vmwTimeoutEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "TIMEOUT_EVENT" + ::= { vmwVRNIEvents 80602} + +vmwFailedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "FAILED_EVENT" + ::= { vmwVRNIEvents 80601} + +vmwNSXTEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Event" + ::= { vmwVRNIEvents 80200} + +vmwNSXTVcNotAddedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "VC Not Added As Data Source Event" + ::= { vmwVRNIEvents 80201} + +vmwNSXTStandaloneHostsEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Standalone hosts added in NSX-T Event" + ::= { vmwVRNIEvents 80202} + +vmwLargeSdmsDroppedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Data Processing Error" + ::= { vmwVRNIEvents 80526} + +vmwNSXTIPFixDFWStatusNotEnabledEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSXT_IPFIX_DFW_STATUS_NOT_ENABLED_EVENT" + ::= { vmwVRNIEvents 80650} + +vmwNSXTIPFixPortIncorrectEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSXT_IPFIX_PORT_INCORRECT_EVENT" + ::= { vmwVRNIEvents 80649} + +vmwNSXTIPFixCollectorAndIPFixProfileMismatchEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSXT_IPFIX_COLLECTOR_AND_IPFIX_PROFILE_MISMATCH_EVENT" + ::= { vmwVRNIEvents 80648} + +vmwNSXTIPFixIPFixProfilePriorityNotZeroEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSXT_IPFIX_IPFIX_PROFILE_PRIORITY_NOT_ZERO_EVENT" + ::= { vmwVRNIEvents 80647} + +vmwNSXTIPFixNoIPFixProfileEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSXT_IPFIX_NO_IPFIX_PROFILE_EVENT" + ::= { vmwVRNIEvents 80646} + +vmwNSXTIPFixNoNewCollectorProfileCanBeAddedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSXT_IPFIX_NO_NEW_COLLECTOR_PROFILE_CAN_BE_ADDED_EVENT" + ::= { vmwVRNIEvents 80645} + +vmwNSXTIPFixNoCollectorProfileEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSXT_IPFIX_NO_COLLECTOR_PROFILE_EVENT" + ::= { vmwVRNIEvents 80644} + +vmwNSXTSystemEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "These are the alarms/events reported by NSX-T. 'Source Component' specifies the entity emmitting this event. + It can be Manager/Controller/Edge. Combination of fields like Source Component, Event Type, Severity and message can be used to troubleshoot NSX-T appliance. + For further information, log into NSX-T Manager UI and visit Dashboard" + ::= { vmwVRNIEvents 80203} + +vmwNSXTNoUplinkConnectivityEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Tier-1 logical router is disconnected from Tier-0 router. Networks under this router are not reachable from outside and vice versa. + For more details, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80205} + +vmwNSXTRoutingAdvertisementEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Routing advertisement is disabled for NSX-T Tier-1 logical router. Networks under this router are not reachable from outside. + For more details, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80206} + +vmwNSXTManagerConnectivityDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Edge Node has lost manager connectivity. + For more details, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80207} + +vmwNSXTControllerConnectivityDegradedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Edge Node is not able to communicate with one or more controllers. + For more details, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80208} + +vmwNSXTControllerConnectivityDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Edge Node is not able to communicate with any of the controllers. + For more details, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80209} + +vmwNSXTMtuMismatchEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "The MTU configured on interface(s) of Tier-0 logical router do not match with the interface(s) of uplink switch/router from same L2 network. This may impact network performance. + For more details, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80210} + +vmwNSXEdgeBGPNeighbourDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One or more BGP neighbours are not in established state. + For more details, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 36067} + +vmwAnalyticsEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Meta event for Analytics Event + For more details, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 37001} + +vmwAnalyticsOutlierEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Meta event for Outlier Events + For more details, please log into vRNI, navigate to Settings -> Events. + " + ::= { vmwVRNIEvents 37002} + +vmwAnalyticsThresholdEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Meta event for Threshold Events + For more details, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 37003} + +vmwVMCEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Meta event for VMC Events. + For more details, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 38001} + +vmwPolicyManagerVrniDfwIPFixCollectorAbsent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Network Insight IPFIX Collector is absent on VMC Policy Manager. + For more details, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80652} + +vmwPolicyManagerNoDfwIPFixProfile NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "DFW IPFIX Profile is absent on VMC Policy Manager. + For more details, please log into vRNI, navigate to Settings -> Events." + ::= { vmwVRNIEvents 80651} + +vmwNSXTExcludedVmFlowEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One or more VMs are not protected by NSX-T DFW firewall. Network Insight will not receive IPFIX flows for these VMs. + Remove the relevant logical switches, logical ports or security groups from the NSX-T firewall exclusion list to enable flows. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80211} + +vmwNSXTDoubleVlanTaggingEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Communication will be disrupted because Vlan on uplink port of Tier 0 router is different than Vlan on the external gateway. + Vlan is misconfigured on the tier-0 router. Make sure Vlan matches with the Vlan on the external gateway. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80212} + +vmwNSXTNoTzAttachedOnTnEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Transport node is not attached to any transport zone. VMs might loose connectivity because of this. + Ensure that the transport node is attached to some transport zone. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80213} + +vmwNSXTVtepDeleteEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "All vteps are deleted from the transport node. VMs might loose connectivity because of this. + Make sure vteps/vmknics are not deleted from the transport node. You may check all available vteps/vmknics in NSX-T->Fabric Nodes->Transport Node->Monitor of each of the impacted transport nodes. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80214} + +vmwDuplicateL3SwitchEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Same Switch or Router is added with different IPs. VM to VM path may not be generated. + Delete duplicate Switches or Routers from Data Source. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80215} + +vmwLBPoolMemberDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "This event is raised when pool member of load balancer is down. + Ensure that pool member has not been disabled by the administrator. + Ensure that pool/pool-member uses the correct Health Monitors which are getting required responses from the backend server. + Ensure that backend server used by this pool member is functional. + For more details, log into Load Balancer UI, navigate to Local Traffic -> Pools -> Pools List. + Also check documentation at https://support.f5.com/csp/article/K12531 + Alternatively, you can log into vRNI UI and search 'Pool Member where state = DISABLED'. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80216} + +vmwLBPoolDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "This event is raised when pool of load balancer is down. + Ensure that pool has at least one functional pool member. + For more details, log into Load Balancer UI, navigate to Local Traffic -> Pools + Also check documentation at https://support.f5.com/csp/article/K12531 + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80217} + +vmwLBPoolEmptyEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "This event is raised when pool of load balancer is empty. + Ensure that pool has at least one pool member. + For more details, log into Load Balancer UI, navigate to Local Traffic -> Pools + Also check documentation at https://support.f5.com/csp/article/K12531 + Alternatively, you can log into vRNI and search 'Pool where PoolMembers Count = 0'. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80218} + +vmwLBPoolMemberVMDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "This event is raised when VM associated with pool member of load balancer is down. + Check if VM associated with pool member is powered on and running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80219} + +vmwLBVirtualServerDisableEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "This event is raised when virtual server of load balancer is disabled. + To enable virtual server, open load balancer GUI and check virtual server state. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80220} + +vmwLBServiceNodeIPNotFoundEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "This event is raised when no NIC associated with IP of service node of load balancer is found. + Ensure that VM which has IP of Service Node exist. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80221} + +vmwLBServiceNodeMultipleNicFoundEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "This event is raised when multiple NICs associated with IP of service node of load balancer are found. + For more details about this event, please log into vRNI, navigate to Settings -> Events." + ::= { vmwVRNIEvents 80222} + +vmwKubernetesInsufficientPrivilegesEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One or more Kubernetes Cluster Service Accounts do not have sufficient privileges. + Please verify that all Kubernetes Cluster Service Accounts has List and Watch privileges. + Refer - https://kubernetes.io/docs/reference/access-authn-authz/rbac/#service-account-permissions + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80655} + +vmwPKSKubernetesUnknownHostEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Please verify the Kubernetes Cluster API Servers are reachable from Collector VM. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80654} + +vmwDatasourceIdentificationChangedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "The data source identity information such as certificate or the key has changed. + Re-verify the identity information on data source page in vRNI. + System will auto accept the new identification. If issue persists for more than an hour, please contact support. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80653} + +vmwArkinApplicationMemberLimitEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Number of members in application exceeds supported limit. + Reduce number of members in the application. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 568} + +vmwNSXTSwitchIpfixEnabledEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Network Insight does not support the IPFIX flow data from NSX-T Switches. It is configured to send IPFIX data to one of the Network Insight Collector VM. It may have corrupted existing flow data in the system. + Remove Network Insight Collector VM IP Address from the NSX-T Switch collector profiles which are used in NSX-T Switch IPFIX profiles. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80223} + +vmwUANIFileNotProvidedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Configuration file required by Generic Routers & Switches Data Source has not been provided while data source creation. To resolve this issue, please go to vRNI web UI, under settings page, edit intended Generic Routers & Switches Data Source and add configuration file. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80657} + +vmwUANIFileDoesNotExistEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Configuration file required by Generic Routers & Switches Data Source has been deleted manually or moved. To resolve this issue, please go to vRNI web UI, under settings page, edit intended Generic Routers & Switches Data Source and add configuration file. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80658} + +vmwNSXTStandaloneHostsWithoutVcEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "vCenter managing one or more fabric nodes in NSX-T is not added as a data source in vRNI. Virtual Machines on those hosts will not be visible in vRNI. + Please add the vCenter server managing the standalone hosts as a datasource into vRNI at- Settings -> Accounts and Data Sources -> Add Source -> VMware vCenter + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80224} + +vmwApplianceNotConfiguredEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Collector VM configuration is incomplete. + To reconfigure proxy, please run 'setup' CLI from console mode. + https://docs.vmware.com/en/VMware-vRealize-Network-Insight/3.8/com.vmware.vrni.cli.doc/GUID-B48AD03A-5FC8-4396-9C27-9523307C688C.html + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80527} + +vmwSwitchPortOperationalDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Switchport operational status change detected. It is operationally down. This may impact the network traffic on the device. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 30111} + +vmwRouterInterfaceOperationalDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Router interface operational status change detected. It is operationally down. This may impact the network traffic on the device. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 30112} + +vmwUnderlayDeviceGenericEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "This is generic representation for events on Underlay device. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 30114} + +vmwUnderlayDeviceFexOfflineEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "A FEX has gone offline on the device. Please check the FEX status on the device. This may impact the network traffic on the device. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 30115} + +vmwUnderlayDeviceFanMalFunctionEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "A fan on the device is not either removed or not working. It may impact the overheating of the device. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 30116} + +vmwUnderlayDeviceTemperatureThresholdExceededEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "A module on the device has reported major/minor temperature alarm. Please check the sensor mentioned in the event message on the device. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 30117} + +vmwUnderlayDeviceFexFanMalFunctionEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "A fan on the FEX chassis is either removed or not working. It may impact the overheating of the FEX device. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 30118} + +vmwUnderlayDeviceFexPsMalFunctionEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "A Power supply on the FEX chassis is either removed or not working. It may impact the FEX device functionality. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 30119} + +vmwUnderlayDeviceModuleMalFunctionEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "A module/line card on the device is either removed or not working. This may impact the network traffic on the device. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 30120} + +vmwUnderlayDevicePsMalFunctionEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "A Power supply on the device is either removed or not working. It may impact the device functionality. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 30121} + +vmwUnderlayDeviceBfdSessionRemovedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "A BFD session is deleted on the device. This will result in routing table changes and may impact the network traffic on the device. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 30122} + +vmwUnderlayDeviceLldpNeighbourRemovedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "A LLDP neighbour is removed from the device. This will result in the network topology changes and may impact the network traffic on the device. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 30123} + +vmwThresholdExceededEventDataSourceCpuUsage NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "A threshold-crossing CPU usage detected on host FRUs. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 30198} + +vmwThresholdExceededEventDataSourceMemoryUsage NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "A threshold-crossing memory usage detected on host FRUs. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 30199} + +vmwThresholdExceededEventDataSourceTemperature NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "A threshold-crossing temperature detected on host FRUs. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 30200} + +vmwDeploymentDefMismatchEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Capacity configuration is mismatched. Please reconfigure. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80532} + +vmwNsxtLatencyServiceConfigMismatchEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "The Latency Service Config configured on NSX-T is different from this Network Insight deployment. As a result, Network Insight is not receiving Latency information from NSX-T. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80669} + +vmwNsxtLatencyNodeGroupMismatchEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "The Latency Node Group configured on NSX-T is different from this Network Insight deployment. As a result, Network Insight is not receiving Latency information from NSX-T. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80668} + +vmwNsxtLatencyStatProfileMismatchEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "The Latency Stat profile configured on NSX-T is different from this Network Insight deployment. As a result, Network Insight is not receiving Latency information from NSX-T. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80667} + +vmwHybridConnectBgpStatusDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "This event is raised when BGP status is Down. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 1279} + +vmwNSXTClusterBackUpDisabledEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Manager backup is not scheduled. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80256} + +vmwNSXTDFWFirewallDisabledEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Distributed Firewall is disabled in the NSX-T Manager. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80257} + +vmwNSXTComputeManagerConnectionStatusNotUpEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Compute Manager Connection status is not up. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80255} + +vmwNSXTLogicalSwitchAdminStatusDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Logical Switch Admin Status is 'Down'. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80252} + +vmwNSXTLogicalPortOperationalStatusDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Logical Port Operational Status is 'Down'. This could cause a communication failure between two virtual interfaces (VIFs) that are connected to the same logical switch, for example, you cannot ping one VM from another. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80253} + +vmwNSXTLogicalPortOperationalStatusUnknownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Logical Port Operational Status is 'Unknown'. This could cause a communication failure between two virtual interfaces (VIFs) that are connected to the same logical switch, for example, you cannot ping one VM from another. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80254} + +vmwNSXTLogicalPortReceivedPacketDropEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Received packets are getting dropped on the NSX-T Logical Port and associated entities might get affected. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80258} + +vmwNSXTLogicalPortTransmittedPacketDropEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Transmitted packets are getting dropped on the NSX-T Logical Port and associated entities might get affected. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80259} + +vmwNSXTLogicalSwitchReceivedPacketDropEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Received packets are getting dropped on the NSX-T Logical Switch and associated entities might get affected. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80260} + +vmwNSXTLogicalSwitchTransmittedPacketDropEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Transmitted packets are getting dropped on the NSX-T Logical Switch and associated entities might get affected. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80261} + +vmwNSXTRxPacketDropOnMPNicEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Received packets are getting dropped on NSX-T Management Node's network interface. This may impact the network traffic related to NSX-T management cluster. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80262} + +vmwNSXTRxPacketDropOnEdgeTnNicEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Received packets are getting dropped on NSX-T Edge Node's network interface. This may impact the network traffic of edge cluster. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80263} + +vmwNSXTRxPacketDropOnHostTnNicEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Received packets are getting dropped on NSX-T Host Node's network interface. This may impact the network traffic on ESXi Host. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80264} + +vmwNSXTTxPacketDropOnMPNicEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Transmitted packets are getting dropped on NSX-T Management Node's network interface. This may impact the network traffic related to NSX-T management cluster. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80265} + +vmwNSXTTxPacketDropOnEdgeTnNicEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Transmitted packets are getting dropped on NSX-T Edge Node's network interface. This may impact the network traffic of edge cluster. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80266} + +vmwNSXTTxPacketDropOnHostTnNicEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Transmitted packets are getting dropped on NSX-T Host Node's network interface. This may impact the network traffic on ESXi Host. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80267} + +vmwNSXTMPNodeServiceClusterManagerStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely Cluster Manager Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80424} + +vmwNSXTMPNodeServiceCmInventoryStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely CM Inventory Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80402} + +vmwNSXTMPNodeServiceControllerStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely Controller Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80403} + +vmwNSXTMPNodeServiceDataStoreStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely DataStore Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80404} + +vmwNSXTMPNodeServiceHttpStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely HTTP Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80405} + +vmwNSXTMPNodeServiceInstallUpgradeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely Install Upgrade Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80406} + +vmwNSXTMPNodeServiceLiagentStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely LI Agent Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80407} + +vmwNSXTMPNodeServiceManagerStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely Manager Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80408} + +vmwNSXTMPNodeServiceMgmtPlaneBusStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely Management Plane Bus Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80409} + +vmwNSXTMPNodeServiceMigrationCoordinatorStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely Migration Co-ordinator Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80410} + +vmwNSXTMPNodeServiceNodeMgmtStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely Node Management Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80411} + +vmwNSXTMPNodeServiceNodeStatsStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely Node Statistics has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80412} + +vmwNSXTMPNodeServiceNSXMessageBusStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely Message Bus Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80413} + +vmwNSXTMPNodeServiceNSXPlatformClientStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely Platform Client Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80414} + +vmwNSXTMPNodeServiceNSXUpgradeAgentStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely Upgrade Agent Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80415} + +vmwNSXTMPNodeServiceNTPStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely NTP Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80416} + +vmwNSXTMPNodeServicePolicyStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely Policy Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80417} + +vmwNSXTMPNodeServiceSearchStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely Search Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80418} + +vmwNSXTMPNodeServiceSNMPStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely SNMP Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80419} + +vmwNSXTMPNodeServiceSSHStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely SSH Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80420} + +vmwNSXTMPNodeServiceSyslogStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely Syslog Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80421} + +vmwNSXTMPNodeServiceTelemetryStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely Telemetry Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80422} + +vmwNSXTMPNodeServiceUIServiceStatusEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "One of the Services of the NSX-T Management Node, namely UI Service has stopped running. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80423} + +vmwVMCHostPerClusterLimitExceededEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "This event is raised when the number of Hosts per Cluster in a VMC SDDC exceeds limit. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 100053} + +vmwVMCVMPerHostLimitExceededEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "This event is raised when the number of VMs per Host in a VMC SDDC exceeds limits. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 100054} + +vmwVMCClusterLimitExceededEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "This event is raised when the number of Clusters in a VMC SDDC exceeds limits. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 100055} + +vmwProtectionEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "This event is raised when any system protection limit is exceeded + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 100061} + +vmwSwitchPortUptimeThresholdRecededEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Up time of switch is less than expected. + Check the operational status of the specified switch port. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 30110} + +vmwFdbConfigStoreCleanupFailedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Foundation Database (FDB) Config Store Cleanup Failed Event. + Data Retention (Config Store Maintenance) service is not healthy. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80531} + +vmwDiskAllocationInsufficientEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Appliance Disk not configured according to Disk Guidance. + https://docs.vmware.com/en/VMware-vRealize-Network-Insight/5.1/com.vmware.vrni.using.doc/GUID-C96E9C78-6FA2-49EB-9791-8967A89B7698.html + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80528} + +vmwNSXTControllerNodeToControlClusterConnectivityEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T controller node has no control cluster connectivity. + Check if the node has proper network connectivity with control cluster. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80225} + +vmwNSXTControllerNodeToMgmtPlaneConnectivityEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T controller node has no management plane connectivity. + Check if the node has proper network connectivity with management plane. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80226} + +vmwNSXTMPNodeToMgmtClusterConnectivityEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T management node has no management cluster connectivity. + Check if the node has proper network connectivity with management cluster. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80227} + +vmwBigIpInsufficientShellAccessEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "No access to shell(ssh port 22) for F5 Load Balancer. Network Insight will not be able to fetch any information required for visibility. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80663} + +vmwBigIpInsufficientPartitionAccessEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Insufficient Partition Access for F5 Load Balancer. Network Insight will not be able to fetch any information required for visibility. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80664} + +vmwBigIpInsufficientRoleEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Insufficient Role for F5 Load Balancer. Network Insight will not be able to fetch any information required for visibility. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80665} + +vmwNSXTLatencyCollectorMismatchEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "The collector configured on NSX-T is different from this Network Insight deployment. As a result, Network Insight is not receiving Latency information from NSX-T. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80662} + +vmwNSXTLatencyNoBFDProfileEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T, no BFD profile configured Event. + BFD profile was deleted on NSX-T Manager after 'Virtual infrastructure Latency' was enabled at Network Insight. As a result, Network Insight is not assigning BFD profile on Transport zone. Network Insight will not receive Latency information from new transport zones. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80661} + +vmwNSXTLatencyMoreBFDProfileEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T, more than one BFD profile configured Event. + There are multiple BFD profiles in the NSX-T Manager. As a result, Network Insight is not assigning correct BFD profile on Transport zone. Network Insight will not receive Latency information from new Transport zones. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80660} + +vmwNSXTLatencyNotEnabledEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T latency collection is not enabled. + Latency collection was disabled in the NSX-T Manager after it was enabled by Network Insight. As a result, Network Insight is not receiving latency information from the NSX-T. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80659} + +vmwHardwareVTEPMismatchEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Hardware Gateway Bindings Mismatch between NSX and switch. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80301} + +vmwHardwareVTEPPortDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Hardware Gateway Binding Switch Port is down. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80302} + +vmwNSXVLatencyNoDataEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Network Insight Collector VM is not receiving network latency metrics from host. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 100001} + +vmwKubernetesBaseEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Event reported by kubernetes cluster. This is Kubernetes System Event. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 1510} + +vmwVMCVMLimitExceededEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Number of VMs in VMC SDDC exceeds limit. + This event is raised when the number of VMs in a VMC SDDC exceeds limits. + Delete VMs that are not in use. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 100051} + +vmwVMCHostLimitExceededEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Number of Hosts in VMC SDDC exceeds limit. + This event is raised when the number of Hosts in a VMC SDDC exceeds limits. + Contact VMC Support to increase the host limit within the VMC SDDC. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 100052} + +vmwVeloCloudEdgeDegradedTransQoeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "VeloCloud Edge Transactional QOE has degraded. + Verify that the Edge is in healthy state. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 90012} + +vmwVeloCloudEdgeDegradedVideoQoeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "VeloCloud Edge Video QOE has Degraded. + Verify that the Edge is in healthy state. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 90011} + +vmwVeloCloudEdgeDegradedVoiceQoeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "VeloCloud Edge Voice QOE has Degraded. + Verify that the Edge is in healthy state. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 90010} + +vmwVeloCloudEdgeDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "VeloCloud Edge is not connected. + Verify that the VeloCloud Edge is UP. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 90001} + +vmwVeloCloudLinkLostPacketEventRx NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Received Packet Loss observed on VeloCloud Link. + Verify that the Link is in healthy state. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 90013} + +vmwVeloCloudLinkDegradedTransQoeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "VeloCloud Link Transactional QOE has Degraded. + Verify that the Link is in healthy state. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 90009} + +vmwVeloCloudLinkLostPacketEventTx NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "Transmitted Packet Loss observed on VeloCloud Link. + Verify that the Link is in healthy state. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 90005} + +vmwVeloCloudLinkDegradedVideoQoeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "VeloCloud Link Video QOE has Degraded. + Verify that the Link is in healthy state. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 90008} + +vmwVeloCloudLinkDegradedVoiceQoeEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "VeloCloud Link Voice QOE has Degraded. + Verify that the Link is in healthy state. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 90007} + +vmwVeloCloudLinkDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "VeloCloud Edge is not connected. + Verify that the VeloCloud Link is UP. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 90002} + +vmwNSXTHostNodeMgmtConnectivityStatusDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Host Transport Node has lost connectivity with NSX-T Manager node. + Please ensure all the interfaces connecting the NSX-T Transport Node to manager are up. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80246} + +vmwNSXTEdgeNodeCtlrConnectivityStatusUnknownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Edge Node Controller connectivity is Unknown. + NSX-T Manager can't determine the status of the Edge Transport Node's connectivity with controller nodes + Please ensure all the interfaces connecting the NSX-T Transport Node to manager are up. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80247} + +vmwNSXTHostNodeCtlrConnectivityStatusDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Host Node is not able to communicate with any of the controllers. + NSX-T Host Transport Node has lost connectivity with all the controller nodes + Please ensure all the interfaces connecting the NSX-T Transport Node to controller nodes are up. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80248} + +vmwNSXTHostNodeCtlrConnectivityStatusDegradedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Host Node is not able to to communicate with one or more controllers. + NSX-T Host Transport Node has lost connectivity with some (but not all) of the controller nodes + Please ensure all the interfaces connecting the NSX-T Transport Node to controller nodes are up. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80249} + +vmwNSXTHostNodeCtlrConnectivityStatusUnknownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Host Node Controller connectivity is Unknown. + NSX-T Manager can't determine the status of the Host Transport Node's connectivity with controller nodes + Please ensure all the interfaces connecting the NSX-T Transport Node to controller nodes are up. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80250} + +vmwNSXTHostNodePnicStatusDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Host Transport Node Pnic Status is 'Down'. + All the pNICs of the NSX-T Host transport Node are down. + Please check if all the pNICs are properly connected. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80228} + +vmwNSXTHostNodePnicStatusDegradedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Host Transport Node Pnic Status is 'Degraded' + Some of the pNICs of the NSX-T Host transport Node are down. + Please check if all the pNICs are properly connected. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80229} + +vmwNSXTHostNodePnicStatusUnknownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Host Transport Node Pnic Status is 'Unknown'. + NSX-T Manager can't determine the status of some or all of the pNICs of the NSX-T Host Transport Node + Please check if all the pNICs are properly connected. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80230} + +vmwNSXTEdgeNodePnicStatusDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Edge Transport Node Pnic Status is 'Down'. + All the pNICs of the NSX-T Edge transport Node are down. + Please check if all the pNICs are properly connected. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80237} + +vmwNSXTEdgeNodePnicStatusDegradedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Edge Transport Node Pnic Status is 'Degraded'. + Some of the pNICs of the NSX-T Edge transport Node are down. + Please check if all the pNICs are properly connected. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80238} + +vmwNSXTEdgeNodePnicStatusUnknownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Edge Transport Node Pnic Status is 'Unknown'. + NSX-T Manager can't determine the status of some or all of the pNICs of the NSX-T Edge Transport Node + Please check if all the pNICs are properly connected. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80239} + +vmwNSXTHostNodeTunnelStatusDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Host Transport Node Tunnel Status is 'Down'. + All the tunnel interfaces associated to the NSX-T Host transport Node are down. + Please check the status of the tunnel interfaces for this NSX-T Transport Node + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80231} + +vmwNSXTHostNodeTunnelStatusDegradedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Host Transport Node Tunnel Status is 'Degraded'. + Some of the tunnel interfaces associated to the NSX-T Host transport Node are down. + Please check the status of the tunnel interfaces for this NSX-T Transport Node + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80232} + +vmwNSXTHostNodeTunnelStatusUnknownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Host Transport Node Tunnel Status is 'Unknown'. + NSX-T Manager can't determine the status of some or all of the tunnel interfaces associated to the NSX-T Host Transport Node. + Please check the status of the tunnel interfaces for this NSX-T Transport Node + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80233} + +vmwNSXTEdgeNodeTunnelStatusDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Edge Transport Node Tunnel Status is 'Down'. + All the tunnel interfaces associated to the NSX-T Edge transport Node are down. + Please check the status of the tunnel interfaces for this NSX-T Transport Node + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80240} + +vmwNSXTEdgeNodeTunnelStatusDegradedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Edge Transport Node Tunnel Status is 'Degraded'. + Some of the tunnel interfaces associated to the NSX-T Edge transport Node are down. + Please check the status of the tunnel interfaces for this NSX-T Transport Node + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80241} + +vmwNSXTEdgeNodeTunnelStatusUnknownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Edge Transport Node Tunnel Status is 'Unknown'. + NSX-T Manager can't determine the status of some or all of the tunnel interfaces associated to the NSX-T Edge Transport Node + Please check the status of the tunnel interfaces for this NSX-T Transport Node + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80242} + +vmwNSXTHostNodeStatusDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Host Transport Node Roll-up Status is 'Down'. + Some or all of the pNICs, management connection, control connections, tunnel statuses, agent statuses of NSX-T Host Transport Node are down. + Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80234} + +vmwNSXTHostNodeStatusDegradedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Host Transport Node Roll-up Status is 'Degraded'. + Some or all of the pNICs, management connection, control connections, tunnel statuses, agent statuses of NSX-T Host Transport Node are in degraded state. + Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80235} + +vmwNSXTHostNodeStatusUnknownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Host Transport Node Roll-up Status is 'Unknown'. + NSX-T Manager can't determine the status of some or all of the pNICs, management connection, control connections, tunnel statuses, agent statuses of NSX-T Host Transport Node. + Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80236} + +vmwNSXTEdgeNodeStatusDownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Edge Transport Node Roll-up Status is 'Down'. + Some or all of the pNICs, management connection, control connections, tunnel statuses, agent statuses of NSX-T Edge Transport Node are down. + Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80243} + +vmwNSXTEdgeNodeStatusDegradedEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Edge Transport Node Roll-up Status is 'Degraded'. + Some or all of the pNICs, management connection, control connections, tunnel statuses, agent statuses of NSX-T Edge Transport Node are in degraded state. + Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80244} + +vmwNSXTEdgeNodeStatusUnknownEvent NOTIFICATION-TYPE + OBJECTS { vmwEventSeverity, vmwAffectedObject, vmwOperatorDesc, vmwVrniUrl, vmwTimestamp, vmwEventName } + STATUS current + DESCRIPTION + "NSX-T Edge Transport Node Roll-up Status is 'Unknown'. + NSX-T Manager can't determine the status of some or all of the pNICs, management connection, control connections, tunnel statuses, agent statuses of NSX-T Edge Transport Node. + Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node. + For more details about this event, please log into vRNI, navigate to Settings -> Events" + ::= { vmwVRNIEvents 80245} + -- ********************************************************** -- Notification parameters -- ********************************************************** @@ -1262,10 +3323,7 @@ vmwEventSeverity OBJECT-TYPE MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION - "Event Severity - For Problems, Major - Opens and alarms, Cleared Closes it - For Notifications - All are Info - " + "vRNI Event Severity" ::= { vmwVRNIData 103} vmwVrniUrl OBJECT-TYPE @@ -1298,8 +3356,7 @@ vmwEventName OBJECT-TYPE MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION - "This is the search string an operator as entered into VRNI. For example: - top 20 vms where cpu utilization > 50%" + "Event name" ::= { vmwVRNIData 107} @@ -1314,7 +3371,7 @@ vmwNetworkInsightMIBBasicCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for entities which implement - VMWARE-VRNI-MIB." + VMWARE-NSX-MANAGER-MIB." MODULE -- this module MANDATORY-GROUPS { vmwNetworkInsightNotificationInfoGroup1, vmwNetworkInsightNotificationGroup1 } @@ -1326,16 +3383,17 @@ vmwNetworkInsightNotificationInfoGroup1 OBJECT-GROUP vmwEventSeverity, vmwVrniUrl, vmwTimestamp, - vmwOperatorDesc + vmwOperatorDesc, + vmwEventName } - STATUS deprecated + STATUS current DESCRIPTION - "These objects provide details in VRNI notifications." + "These objects provide details in NSX Manager notifications." ::= { vmwNetworkInsightMIBGroups 2 } vmwNetworkInsightNotificationGroup1 NOTIFICATION-GROUP - NOTIFICATIONS { - vmwSnmpTrapsAreConfigured, + NOTIFICATIONS { + vmwSnmpTrapsAreConfigured, vmwSnmpTrapsAreDisabled, vmwTestTrap, vmwEntityDiscoveryChangeEvent, @@ -1484,11 +3542,11 @@ vmwNetworkInsightNotificationGroup1 NOTIFICATION-GROUP vmwPanNsxServiceApplianceViewMismatchEvent, vmwPanNsxFabricAgentNotFoundOnHostEvent, vmwPanNsxServiceVMNotFoundOnHostEvent - } - STATUS current - DESCRIPTION - "Set of notifications (traps, informs) supported in this first version." - ::= { vmwNetworkInsightMIBGroups 3 } +} + STATUS current + DESCRIPTION + "Set of notifications (traps, informs) supported in this version." + ::= { vmwNetworkInsightMIBGroups 3 } vmwNetworkInsightMIBBasicCompliance2 MODULE-COMPLIANCE STATUS deprecated @@ -1511,7 +3569,7 @@ vmwNetworkInsightNotificationInfoGroup2 OBJECT-GROUP vmwOperatorDesc, vmwEventName } - STATUS current + STATUS deprecated DESCRIPTION "These events provide details in NSX Manager notifications." ::= { vmwNetworkInsightMIBGroups 20 } @@ -1579,7 +3637,7 @@ vmwNetworkInsightNotificationGroup3 NOTIFICATION-GROUP ::= { vmwNetworkInsightMIBGroups 40 } vmwNetworkInsightMIBBasicCompliance4 MODULE-COMPLIANCE - STATUS current + STATUS deprecated DESCRIPTION "The compliance statement for entities which implement VMWARE-VRNI-MIB second version." @@ -1614,4 +3672,421 @@ vmwNetworkInsightNotificationGroup4 NOTIFICATION-GROUP "Set of added notifications (traps, informs) since last revision." ::= { vmwNetworkInsightMIBGroups 50 } -END +vmwNetworkInsightNotificationInfoGroup3 OBJECT-GROUP + OBJECTS { + vmwEventSeverity, + vmwAffectedObject, + vmwOperatorDesc, + vmwVrniUrl, + vmwTimestamp, + vmwEventName + } + STATUS current + DESCRIPTION + "These objects provide details in VRNI notifications." + ::= { vmwNetworkInsightMIBGroups 55 } + +vmwNetworkInsightMIBBasicCompliance5 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for entities which implement + VMWARE-VRNI-MIB latest version." + MODULE -- this module + MANDATORY-GROUPS { vmwNetworkInsightNotificationInfoGroup3, + vmwNetworkInsightNotificationGroup1, + vmwNetworkInsightNotificationGroup2, + vmwNetworkInsightNotificationGroup3, + vmwNetworkInsightNotificationGroup4, + vmwNetworkInsightNotificationGroup5 + } + ::= { vmwNetworkInsightMIBCompliances 60 } + +vmwNetworkInsightMIBBasicCompliance6 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for entities which implement + VMWARE-VRNI-MIB latest version." + MODULE -- this module + MANDATORY-GROUPS { vmwNetworkInsightNotificationInfoGroup3, + vmwNetworkInsightNotificationGroup1, + vmwNetworkInsightNotificationGroup2, + vmwNetworkInsightNotificationGroup3, + vmwNetworkInsightNotificationGroup4, + vmwNetworkInsightNotificationGroup5, + vmwNetworkInsightNotificationGroup6 + } + ::= { vmwNetworkInsightMIBCompliances 70 } + +vmwNetworkInsightMIBBasicCompliance7 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for entities which implement + VMWARE-VRNI-MIB latest version." + MODULE -- this module + MANDATORY-GROUPS { vmwNetworkInsightNotificationInfoGroup3, + vmwNetworkInsightNotificationGroup1, + vmwNetworkInsightNotificationGroup2, + vmwNetworkInsightNotificationGroup3, + vmwNetworkInsightNotificationGroup4, + vmwNetworkInsightNotificationGroup5, + vmwNetworkInsightNotificationGroup6, + vmwNetworkInsightNotificationGroup7 + } + ::= { vmwNetworkInsightMIBCompliances 80 } + +vmwNetworkInsightMIBBasicCompliance8 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for entities which implement + VMWARE-VRNI-MIB latest version." + MODULE -- this module + MANDATORY-GROUPS { vmwNetworkInsightNotificationInfoGroup3, + vmwNetworkInsightNotificationGroup1, + vmwNetworkInsightNotificationGroup2, + vmwNetworkInsightNotificationGroup3, + vmwNetworkInsightNotificationGroup4, + vmwNetworkInsightNotificationGroup5, + vmwNetworkInsightNotificationGroup6, + vmwNetworkInsightNotificationGroup7, + vmwNetworkInsightNotificationGroup8 + } + ::= { vmwNetworkInsightMIBCompliances 90 } + +vmwNetworkInsightMIBBasicCompliance9 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The compliance statement for entities which implement + VMWARE-VRNI-MIB latest version." + MODULE -- this module + MANDATORY-GROUPS { vmwNetworkInsightNotificationInfoGroup3, + vmwNetworkInsightNotificationGroup1, + vmwNetworkInsightNotificationGroup2, + vmwNetworkInsightNotificationGroup3, + vmwNetworkInsightNotificationGroup4, + vmwNetworkInsightNotificationGroup5, + vmwNetworkInsightNotificationGroup6, + vmwNetworkInsightNotificationGroup7, + vmwNetworkInsightNotificationGroup8, + vmwNetworkInsightNotificationGroup9 + } + ::= { vmwNetworkInsightMIBCompliances 100 } + +vmwNetworkInsightMIBBasicCompliance10 MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The compliance statement for entities which implement + VMWARE-VRNI-MIB latest version." + MODULE -- this module + MANDATORY-GROUPS { vmwNetworkInsightNotificationInfoGroup3, + vmwNetworkInsightNotificationGroup1, + vmwNetworkInsightNotificationGroup2, + vmwNetworkInsightNotificationGroup3, + vmwNetworkInsightNotificationGroup4, + vmwNetworkInsightNotificationGroup5, + vmwNetworkInsightNotificationGroup6, + vmwNetworkInsightNotificationGroup7, + vmwNetworkInsightNotificationGroup8, + vmwNetworkInsightNotificationGroup9, + vmwNetworkInsightNotificationGroup10 + } + ::= { vmwNetworkInsightMIBCompliances 110 } + +vmwNetworkInsightNotificationGroup5 NOTIFICATION-GROUP + NOTIFICATIONS { + vmwNiInfraChangeEvent, + vmwDataSourceEnabledChangeEvent, + vmwDataSourceDisabledChangeEvent, + vmwDataSourceCreatedEvent, + vmwPlatformCpuCoreChangeEvent, + vmwPlatformDiskChangeEvent, + vmwPlatformMemoryChangeEvent, + vmwPlatformRebootedEvent, + vmwProxyCpuCoreChangeEvent, + vmwProxyDiskChangeEvent, + vmwProxyMemoryChangeEvent, + vmwProxyRebootedEvent, + vmwNIClusterChangeEvent, + vmwNISystemProxyChangeEvent, + vmwNIClusterCreateEvent, + vmwAWSRegionSGLimitEvent, + vmwAWSVPCSGLimitEvent, + vmwAWSSGInboundRuleLimitEvent, + vmwAWSSGOutboundRuleLimitEvent, + vmwAWSInterfaceSGLimitEvent, + vmwVirtualDistributedRoutingEvent, + vmwIndexerLagEvent, + vmwIPFIXFlowDPPausedEvent, + vmwGridProcessingStoppedEvent, + vmwUnableToSendEmailsEvent, + vmwSMTPNotConfiguredEvent, + vmwSNMPNotConfiguredEvent, + vmwReindexingInProgressEvent, + vmwNodesVersionMismatchEvent, + vmwNotAllServicesRunningEvent, + vmwNotAllServicesHealthyEvent, + vmwExpandPartitionFailedEvent, + vmwDiskCleanupFailedEvent, + vmwVaccumFailedEvent, + vmwConfigStoreCleanupFailedEvent, + vmwHBaseRetentionToolFailedEvent, + vmwMetricStoreUpdaterFailedEvent, + vmwCollectorLagEvent, + vmwCollectionLagEvent, + vmwGridProcessingLagEvent, + vmwConnectionErrorEvent, + vmwNodeNotActiveEvent, + vmwHighDiskUtilizationEvent, + vmwIndexingAbortedEvent, + vmwUpgradeFailedEvent, + vmwFlowProcessingSuspendedEvent, + vmwVCNotOnSameProxyEvent, + vmwNoDVSAvailableEvent, + vmwUnknownInfobloxVersionEvent, + vmwUnsupportedInfobloxVersionEvent, + vmwIncorrectInfobloxCredentialEvent, + vmwInfobloxRecordLimitExceededEvent, + vmwWebhookNotRunningEvent, + vmwIncorrectWebhookConfiguredOnAlertEvent, + vmwWebhookNotEnabledOnAlertEvent, + vmwVRNIContentPackNotInstalledEvent, + vmwUnsupportedVRNIContentPackVersionEvent, + vmwUnsupportedLogInsightVersionEvent, + vmwComputeManagersNotAddedEvent, + vmwComputeManagersNotFoundEvent, + vmwUnsupportedNSXTVersionEvent, + vmwNotEmptyNodeEvent, + vmwFlowPhysicalNodeEvent, + vmwFlowCollectionErrorEvent, + vmwAWSThrottlingExceptionEvent, + vmwAWSFlowLogAccessDeniedExceptionEvent, + vmwNSXIPFIXStatusMismatchEvent, + vmwNumVMsOrHostsNotFoundEvent, + vmwUnsupportedNSXVersionEvent, + vmwPwdAuthModeDisabledAristaEvent, + vmwHostnameResolutionErrorEvent, + vmwPrimaryNSXNotAddedEvent, + vmwDataProviderNotRunningEvent, + vmwInvalidResponseFromDatasourceEvent, + vmwHostNotReachableEvent, + vmwNSXControllerNotFoundEvent, + vmwUnexpectedDSTypeOrVersionEvent, + vmwWarnConfigEvent, + vmwInvalidConfigEvent, + vmwNotFoundEvent, + vmwInsufficientPrivilegesEvent, + vmwPwdAuthModeDisabledEvent, + vmwFailedCredsEncryptEvent, + vmwSNMPConnectionInvalidEvent, + vmwUnknownHostEvent, + vmwInvalidCredentialsEvent, + vmwIncorrectConnectionStringEvent, + vmwConnectionRefusedEvent, + vmwTimeoutEvent, + vmwFailedEvent, + vmwNSXTEvent, + vmwNSXTVcNotAddedEvent, + vmwNSXTStandaloneHostsEvent, + vmwLargeSdmsDroppedEvent, + vmwNSXTIPFixDFWStatusNotEnabledEvent, + vmwNSXTIPFixPortIncorrectEvent, + vmwNSXTIPFixCollectorAndIPFixProfileMismatchEvent, + vmwNSXTIPFixIPFixProfilePriorityNotZeroEvent, + vmwNSXTIPFixNoIPFixProfileEvent, + vmwNSXTIPFixNoNewCollectorProfileCanBeAddedEvent, + vmwNSXTIPFixNoCollectorProfileEvent + } + STATUS current + DESCRIPTION + "Set of added notifications (traps, informs) since last revision." + ::= { vmwNetworkInsightMIBGroups 65 } + + vmwNetworkInsightNotificationGroup6 NOTIFICATION-GROUP + NOTIFICATIONS { + vmwNSXTSystemEvent, + vmwNSXTNoUplinkConnectivityEvent, + vmwNSXTRoutingAdvertisementEvent, + vmwNSXTManagerConnectivityDownEvent, + vmwNSXTControllerConnectivityDegradedEvent, + vmwNSXTControllerConnectivityDownEvent, + vmwNSXTMtuMismatchEvent, + vmwNSXEdgeBGPNeighbourDownEvent, + vmwAnalyticsEvent, + vmwAnalyticsOutlierEvent, + vmwAnalyticsThresholdEvent, + vmwVMCEvent, + vmwPolicyManagerVrniDfwIPFixCollectorAbsent, + vmwPolicyManagerNoDfwIPFixProfile + } + STATUS current + DESCRIPTION + "Set of added notifications (traps, informs) for 4.0.0 release." + ::= { vmwNetworkInsightMIBGroups 75 } + + vmwNetworkInsightNotificationGroup7 NOTIFICATION-GROUP + NOTIFICATIONS { + vmwNSXTDoubleVlanTaggingEvent, + vmwNSXTVtepDeleteEvent, + vmwNSXTNoTzAttachedOnTnEvent, + vmwNSXTExcludedVmFlowEvent, + vmwKubernetesInsufficientPrivilegesEvent, + vmwPKSKubernetesUnknownHostEvent, + vmwDatasourceIdentificationChangedEvent, + vmwLBPoolMemberDownEvent, + vmwLBPoolDownEvent, + vmwLBPoolMemberVMDownEvent, + vmwLBServiceNodeIPNotFoundEvent, + vmwLBServiceNodeMultipleNicFoundEvent, + vmwLBVirtualServerDisableEvent, + vmwLBPoolEmptyEvent, + vmwDuplicateL3SwitchEvent, + vmwArkinApplicationMemberLimitEvent, + vmwNSXTSwitchIpfixEnabledEvent + } + STATUS current + DESCRIPTION + "Set of added notifications (traps, informs) for 4.1.0 release." + ::= { vmwNetworkInsightMIBGroups 85 } + + vmwNetworkInsightNotificationGroup8 NOTIFICATION-GROUP + NOTIFICATIONS { + vmwUANIFileNotProvidedEvent, + vmwUANIFileDoesNotExistEvent + } + STATUS current + DESCRIPTION + "Set of added notifications (traps, informs) for 4.2.0 release." + ::= { vmwNetworkInsightMIBGroups 95 } + + vmwNetworkInsightNotificationGroup9 NOTIFICATION-GROUP + NOTIFICATIONS { + vmwNSXTStandaloneHostsWithoutVcEvent, + vmwApplianceNotConfiguredEvent + } + STATUS current + DESCRIPTION + "Set of added notifications (traps, informs) for 5.0.0 release." + ::= { vmwNetworkInsightMIBGroups 105 } + + vmwNetworkInsightNotificationGroup10 NOTIFICATION-GROUP + NOTIFICATIONS { + vmwSwitchPortUptimeThresholdRecededEvent, + vmwFdbConfigStoreCleanupFailedEvent, + vmwDiskAllocationInsufficientEvent, + vmwNSXTControllerNodeToControlClusterConnectivityEvent, + vmwNSXTControllerNodeToMgmtPlaneConnectivityEvent, + vmwNSXTMPNodeToMgmtClusterConnectivityEvent, + vmwBigIpInsufficientShellAccessEvent, + vmwBigIpInsufficientPartitionAccessEvent, + vmwBigIpInsufficientRoleEvent, + vmwNSXTLatencyCollectorMismatchEvent, + vmwNSXTLatencyNoBFDProfileEvent, + vmwNSXTLatencyMoreBFDProfileEvent, + vmwNSXTLatencyNotEnabledEvent, + vmwHardwareVTEPMismatchEvent, + vmwHardwareVTEPPortDownEvent, + vmwNSXVLatencyNoDataEvent, + vmwKubernetesBaseEvent, + vmwVMCVMLimitExceededEvent, + vmwVMCHostLimitExceededEvent, + vmwVeloCloudEdgeDegradedTransQoeEvent, + vmwVeloCloudEdgeDegradedVideoQoeEvent, + vmwVeloCloudEdgeDegradedVoiceQoeEvent, + vmwVeloCloudEdgeDownEvent, + vmwVeloCloudLinkLostPacketEventRx, + vmwVeloCloudLinkDegradedTransQoeEvent, + vmwVeloCloudLinkLostPacketEventTx, + vmwVeloCloudLinkDegradedVideoQoeEvent, + vmwVeloCloudLinkDegradedVoiceQoeEvent, + vmwVeloCloudLinkDownEvent, + vmwNSXTHostNodeMgmtConnectivityStatusDownEvent, + vmwNSXTEdgeNodeCtlrConnectivityStatusUnknownEvent, + vmwNSXTHostNodeCtlrConnectivityStatusDownEvent, + vmwNSXTHostNodeCtlrConnectivityStatusDegradedEvent, + vmwNSXTHostNodeCtlrConnectivityStatusUnknownEvent, + vmwNSXTHostNodePnicStatusDownEvent, + vmwNSXTHostNodePnicStatusDegradedEvent, + vmwNSXTHostNodePnicStatusUnknownEvent, + vmwNSXTEdgeNodePnicStatusDownEvent, + vmwNSXTEdgeNodePnicStatusDegradedEvent, + vmwNSXTEdgeNodePnicStatusUnknownEvent, + vmwNSXTHostNodeTunnelStatusDownEvent, + vmwNSXTHostNodeTunnelStatusDegradedEvent, + vmwNSXTHostNodeTunnelStatusUnknownEvent, + vmwNSXTEdgeNodeTunnelStatusDownEvent, + vmwNSXTEdgeNodeTunnelStatusDegradedEvent, + vmwNSXTEdgeNodeTunnelStatusUnknownEvent, + vmwNSXTHostNodeStatusDownEvent, + vmwNSXTHostNodeStatusDegradedEvent, + vmwNSXTHostNodeStatusUnknownEvent, + vmwNSXTEdgeNodeStatusDownEvent, + vmwNSXTEdgeNodeStatusDegradedEvent, + vmwNSXTEdgeNodeStatusUnknownEvent, + vmwSwitchPortOperationalDownEvent, + vmwRouterInterfaceOperationalDownEvent, + vmwUnderlayDeviceGenericEvent, + vmwUnderlayDeviceFexOfflineEvent, + vmwUnderlayDeviceFanMalFunctionEvent, + vmwUnderlayDeviceTemperatureThresholdExceededEvent, + vmwUnderlayDeviceFexFanMalFunctionEvent, + vmwUnderlayDeviceFexPsMalFunctionEvent, + vmwUnderlayDeviceModuleMalFunctionEvent, + vmwUnderlayDevicePsMalFunctionEvent, + vmwUnderlayDeviceBfdSessionRemovedEvent, + vmwUnderlayDeviceLldpNeighbourRemovedEvent, + vmwThresholdExceededEventDataSourceCpuUsage, + vmwThresholdExceededEventDataSourceMemoryUsage, + vmwThresholdExceededEventDataSourceTemperature, + vmwDeploymentDefMismatchEvent, + vmwNsxtLatencyServiceConfigMismatchEvent, + vmwNsxtLatencyNodeGroupMismatchEvent, + vmwNsxtLatencyStatProfileMismatchEvent, + vmwHybridConnectBgpStatusDownEvent, + vmwNSXTClusterBackUpDisabledEvent, + vmwNSXTDFWFirewallDisabledEvent, + vmwNSXTComputeManagerConnectionStatusNotUpEvent, + vmwNSXTLogicalSwitchAdminStatusDownEvent, + vmwNSXTLogicalPortOperationalStatusDownEvent, + vmwNSXTLogicalPortOperationalStatusUnknownEvent, + vmwNSXTLogicalPortReceivedPacketDropEvent, + vmwNSXTLogicalPortTransmittedPacketDropEvent, + vmwNSXTLogicalSwitchReceivedPacketDropEvent, + vmwNSXTLogicalSwitchTransmittedPacketDropEvent, + vmwNSXTRxPacketDropOnMPNicEvent, + vmwNSXTRxPacketDropOnEdgeTnNicEvent, + vmwNSXTRxPacketDropOnHostTnNicEvent, + vmwNSXTTxPacketDropOnMPNicEvent, + vmwNSXTTxPacketDropOnEdgeTnNicEvent, + vmwNSXTTxPacketDropOnHostTnNicEvent, + vmwNSXTMPNodeServiceClusterManagerStatusEvent, + vmwNSXTMPNodeServiceCmInventoryStatusEvent, + vmwNSXTMPNodeServiceControllerStatusEvent, + vmwNSXTMPNodeServiceDataStoreStatusEvent, + vmwNSXTMPNodeServiceHttpStatusEvent, + vmwNSXTMPNodeServiceInstallUpgradeEvent, + vmwNSXTMPNodeServiceLiagentStatusEvent, + vmwNSXTMPNodeServiceManagerStatusEvent, + vmwNSXTMPNodeServiceMgmtPlaneBusStatusEvent, + vmwNSXTMPNodeServiceMigrationCoordinatorStatusEvent, + vmwNSXTMPNodeServiceNodeMgmtStatusEvent, + vmwNSXTMPNodeServiceNodeStatsStatusEvent, + vmwNSXTMPNodeServiceNSXMessageBusStatusEvent, + vmwNSXTMPNodeServiceNSXPlatformClientStatusEvent, + vmwNSXTMPNodeServiceNSXUpgradeAgentStatusEvent, + vmwNSXTMPNodeServiceNTPStatusEvent, + vmwNSXTMPNodeServicePolicyStatusEvent, + vmwNSXTMPNodeServiceSearchStatusEvent, + vmwNSXTMPNodeServiceSNMPStatusEvent, + vmwNSXTMPNodeServiceSSHStatusEvent, + vmwNSXTMPNodeServiceSyslogStatusEvent, + vmwNSXTMPNodeServiceTelemetryStatusEvent, + vmwNSXTMPNodeServiceUIServiceStatusEvent, + vmwVMCHostPerClusterLimitExceededEvent, + vmwVMCVMPerHostLimitExceededEvent, + vmwVMCClusterLimitExceededEvent, + vmwProtectionEvent + } + STATUS current + DESCRIPTION + "Set of added notifications (traps, informs) for 5.2.0 release." + ::= { vmwNetworkInsightMIBGroups 115 } +END \ No newline at end of file diff --git a/tests/data/vmware-esxi.json b/tests/data/vmware-esxi.json new file mode 100644 index 0000000000..df3be66b60 --- /dev/null +++ b/tests/data/vmware-esxi.json @@ -0,0 +1,1901 @@ +{ + "os": { + "discovery": { + "devices": [ + { + "sysName": "", + "sysObjectID": ".1.3.6.1.4.1.6876.4.1", + "sysDescr": "VMware ESXi 7.0.0 build-15843807 VMware, Inc. x86_64", + "sysContact": null, + "version": "7.0.0", + "hardware": "HP ProLiant DL380p Gen8", + "features": "build 15843807", + "os": "vmware-esxi", + "type": "server", + "serial": "CZ162913BZ", + "icon": "vmware.svg", + "location": "" + } + ] + }, + "poller": { + "devices": [ + { + "sysName": "", + "sysObjectID": ".1.3.6.1.4.1.6876.4.1", + "sysDescr": "VMware ESXi 7.0.0 build-15843807 VMware, Inc. x86_64", + "sysContact": "", + "version": "7.0.0", + "hardware": "HP ProLiant DL380p Gen8", + "features": "build 15843807", + "os": "vmware-esxi", + "type": "server", + "serial": "CZ162913BZ", + "icon": "vmware.svg", + "location": "" + } + ] + } + }, + "ports": { + "discovery": { + "ports": [ + { + "port_descr_type": null, + "port_descr_descr": null, + "port_descr_circuit": null, + "port_descr_speed": null, + "port_descr_notes": null, + "ifDescr": "Device vmnic4 at 07:00.0 i40en", + "ifName": "vmnic4", + "portName": null, + "ifIndex": 1, + "ifSpeed": null, + "ifSpeed_prev": null, + "ifConnectorPresent": null, + "ifPromiscuousMode": null, + "ifHighSpeed": null, + "ifHighSpeed_prev": null, + "ifOperStatus": "up", + "ifOperStatus_prev": null, + "ifAdminStatus": null, + "ifAdminStatus_prev": null, + "ifDuplex": null, + "ifMtu": null, + "ifType": "ethernetCsmacd", + "ifAlias": "07:00.0", + "ifPhysAddress": null, + "ifHardType": null, + "ifLastChange": 0, + "ifVlan": "", + "ifTrunk": null, + "counter_in": null, + "counter_out": null, + "ignore": 0, + "disabled": 0, + "detailed": 0, + "deleted": 0, + "pagpOperationMode": null, + "pagpPortState": null, + "pagpPartnerDeviceId": null, + "pagpPartnerLearnMethod": null, + "pagpPartnerIfIndex": null, + "pagpPartnerGroupIfIndex": null, + "pagpPartnerDeviceName": null, + "pagpEthcOperationMode": null, + "pagpDeviceId": null, + "pagpGroupIfIndex": null, + "ifInUcastPkts": null, + "ifInUcastPkts_prev": null, + "ifInUcastPkts_delta": null, + "ifInUcastPkts_rate": null, + "ifOutUcastPkts": null, + "ifOutUcastPkts_prev": null, + "ifOutUcastPkts_delta": null, + "ifOutUcastPkts_rate": null, + "ifInErrors": null, + "ifInErrors_prev": null, + "ifInErrors_delta": null, + "ifInErrors_rate": null, + "ifOutErrors": null, + "ifOutErrors_prev": null, + "ifOutErrors_delta": null, + "ifOutErrors_rate": null, + "ifInOctets": null, + "ifInOctets_prev": null, + "ifInOctets_delta": null, + "ifInOctets_rate": null, + "ifOutOctets": null, + "ifOutOctets_prev": null, + "ifOutOctets_delta": null, + "ifOutOctets_rate": null, + "poll_prev": null, + "ifInNUcastPkts": null, + "ifInNUcastPkts_prev": null, + "ifInNUcastPkts_delta": null, + "ifInNUcastPkts_rate": null, + "ifOutNUcastPkts": null, + "ifOutNUcastPkts_prev": null, + "ifOutNUcastPkts_delta": null, + "ifOutNUcastPkts_rate": null, + "ifInDiscards": null, + "ifInDiscards_prev": null, + "ifInDiscards_delta": null, + "ifInDiscards_rate": null, + "ifOutDiscards": null, + "ifOutDiscards_prev": null, + "ifOutDiscards_delta": null, + "ifOutDiscards_rate": null, + "ifInUnknownProtos": null, + "ifInUnknownProtos_prev": null, + "ifInUnknownProtos_delta": null, + "ifInUnknownProtos_rate": null, + "ifInBroadcastPkts": null, + "ifInBroadcastPkts_prev": null, + "ifInBroadcastPkts_delta": null, + "ifInBroadcastPkts_rate": null, + "ifOutBroadcastPkts": null, + "ifOutBroadcastPkts_prev": null, + "ifOutBroadcastPkts_delta": null, + "ifOutBroadcastPkts_rate": null, + "ifInMulticastPkts": null, + "ifInMulticastPkts_prev": null, + "ifInMulticastPkts_delta": null, + "ifInMulticastPkts_rate": null, + "ifOutMulticastPkts": null, + "ifOutMulticastPkts_prev": null, + "ifOutMulticastPkts_delta": null, + "ifOutMulticastPkts_rate": null + }, + { + "port_descr_type": null, + "port_descr_descr": null, + "port_descr_circuit": null, + "port_descr_speed": null, + "port_descr_notes": null, + "ifDescr": "Device vmnic5 at 07:00.1 i40en", + "ifName": "vmnic5", + "portName": null, + "ifIndex": 2, + "ifSpeed": null, + "ifSpeed_prev": null, + "ifConnectorPresent": null, + "ifPromiscuousMode": null, + "ifHighSpeed": null, + "ifHighSpeed_prev": null, + "ifOperStatus": "up", + "ifOperStatus_prev": null, + "ifAdminStatus": null, + "ifAdminStatus_prev": null, + "ifDuplex": null, + "ifMtu": null, + "ifType": "ethernetCsmacd", + "ifAlias": "07:00.1", + "ifPhysAddress": null, + "ifHardType": null, + "ifLastChange": 0, + "ifVlan": "", + "ifTrunk": null, + "counter_in": null, + "counter_out": null, + "ignore": 0, + "disabled": 0, + "detailed": 0, + "deleted": 0, + "pagpOperationMode": null, + "pagpPortState": null, + "pagpPartnerDeviceId": null, + "pagpPartnerLearnMethod": null, + "pagpPartnerIfIndex": null, + "pagpPartnerGroupIfIndex": null, + "pagpPartnerDeviceName": null, + "pagpEthcOperationMode": null, + "pagpDeviceId": null, + "pagpGroupIfIndex": null, + "ifInUcastPkts": null, + "ifInUcastPkts_prev": null, + "ifInUcastPkts_delta": null, + "ifInUcastPkts_rate": null, + "ifOutUcastPkts": null, + "ifOutUcastPkts_prev": null, + "ifOutUcastPkts_delta": null, + "ifOutUcastPkts_rate": null, + "ifInErrors": null, + "ifInErrors_prev": null, + "ifInErrors_delta": null, + "ifInErrors_rate": null, + "ifOutErrors": null, + "ifOutErrors_prev": null, + "ifOutErrors_delta": null, + "ifOutErrors_rate": null, + "ifInOctets": null, + "ifInOctets_prev": null, + "ifInOctets_delta": null, + "ifInOctets_rate": null, + "ifOutOctets": null, + "ifOutOctets_prev": null, + "ifOutOctets_delta": null, + "ifOutOctets_rate": null, + "poll_prev": null, + "ifInNUcastPkts": null, + "ifInNUcastPkts_prev": null, + "ifInNUcastPkts_delta": null, + "ifInNUcastPkts_rate": null, + "ifOutNUcastPkts": null, + "ifOutNUcastPkts_prev": null, + "ifOutNUcastPkts_delta": null, + "ifOutNUcastPkts_rate": null, + "ifInDiscards": null, + "ifInDiscards_prev": null, + "ifInDiscards_delta": null, + "ifInDiscards_rate": null, + "ifOutDiscards": null, + "ifOutDiscards_prev": null, + "ifOutDiscards_delta": null, + "ifOutDiscards_rate": null, + "ifInUnknownProtos": null, + "ifInUnknownProtos_prev": null, + "ifInUnknownProtos_delta": null, + "ifInUnknownProtos_rate": null, + "ifInBroadcastPkts": null, + "ifInBroadcastPkts_prev": null, + "ifInBroadcastPkts_delta": null, + "ifInBroadcastPkts_rate": null, + "ifOutBroadcastPkts": null, + "ifOutBroadcastPkts_prev": null, + "ifOutBroadcastPkts_delta": null, + "ifOutBroadcastPkts_rate": null, + "ifInMulticastPkts": null, + "ifInMulticastPkts_prev": null, + "ifInMulticastPkts_delta": null, + "ifInMulticastPkts_rate": null, + "ifOutMulticastPkts": null, + "ifOutMulticastPkts_prev": null, + "ifOutMulticastPkts_delta": null, + "ifOutMulticastPkts_rate": null + }, + { + "port_descr_type": null, + "port_descr_descr": null, + "port_descr_circuit": null, + "port_descr_speed": null, + "port_descr_notes": null, + "ifDescr": "Device vmnic0 at 03:00.0 ntg3", + "ifName": "vmnic0", + "portName": null, + "ifIndex": 3, + "ifSpeed": null, + "ifSpeed_prev": null, + "ifConnectorPresent": null, + "ifPromiscuousMode": null, + "ifHighSpeed": null, + "ifHighSpeed_prev": null, + "ifOperStatus": "down", + "ifOperStatus_prev": null, + "ifAdminStatus": null, + "ifAdminStatus_prev": null, + "ifDuplex": null, + "ifMtu": null, + "ifType": "ethernetCsmacd", + "ifAlias": "03:00.0", + "ifPhysAddress": null, + "ifHardType": null, + "ifLastChange": 0, + "ifVlan": "", + "ifTrunk": null, + "counter_in": null, + "counter_out": null, + "ignore": 0, + "disabled": 0, + "detailed": 0, + "deleted": 0, + "pagpOperationMode": null, + "pagpPortState": null, + "pagpPartnerDeviceId": null, + "pagpPartnerLearnMethod": null, + "pagpPartnerIfIndex": null, + "pagpPartnerGroupIfIndex": null, + "pagpPartnerDeviceName": null, + "pagpEthcOperationMode": null, + "pagpDeviceId": null, + "pagpGroupIfIndex": null, + "ifInUcastPkts": null, + "ifInUcastPkts_prev": null, + "ifInUcastPkts_delta": null, + "ifInUcastPkts_rate": null, + "ifOutUcastPkts": null, + "ifOutUcastPkts_prev": null, + "ifOutUcastPkts_delta": null, + "ifOutUcastPkts_rate": null, + "ifInErrors": null, + "ifInErrors_prev": null, + "ifInErrors_delta": null, + "ifInErrors_rate": null, + "ifOutErrors": null, + "ifOutErrors_prev": null, + "ifOutErrors_delta": null, + "ifOutErrors_rate": null, + "ifInOctets": null, + "ifInOctets_prev": null, + "ifInOctets_delta": null, + "ifInOctets_rate": null, + "ifOutOctets": null, + "ifOutOctets_prev": null, + "ifOutOctets_delta": null, + "ifOutOctets_rate": null, + "poll_prev": null, + "ifInNUcastPkts": null, + "ifInNUcastPkts_prev": null, + "ifInNUcastPkts_delta": null, + "ifInNUcastPkts_rate": null, + "ifOutNUcastPkts": null, + "ifOutNUcastPkts_prev": null, + "ifOutNUcastPkts_delta": null, + "ifOutNUcastPkts_rate": null, + "ifInDiscards": null, + "ifInDiscards_prev": null, + "ifInDiscards_delta": null, + "ifInDiscards_rate": null, + "ifOutDiscards": null, + "ifOutDiscards_prev": null, + "ifOutDiscards_delta": null, + "ifOutDiscards_rate": null, + "ifInUnknownProtos": null, + "ifInUnknownProtos_prev": null, + "ifInUnknownProtos_delta": null, + "ifInUnknownProtos_rate": null, + "ifInBroadcastPkts": null, + "ifInBroadcastPkts_prev": null, + "ifInBroadcastPkts_delta": null, + "ifInBroadcastPkts_rate": null, + "ifOutBroadcastPkts": null, + "ifOutBroadcastPkts_prev": null, + "ifOutBroadcastPkts_delta": null, + "ifOutBroadcastPkts_rate": null, + "ifInMulticastPkts": null, + "ifInMulticastPkts_prev": null, + "ifInMulticastPkts_delta": null, + "ifInMulticastPkts_rate": null, + "ifOutMulticastPkts": null, + "ifOutMulticastPkts_prev": null, + "ifOutMulticastPkts_delta": null, + "ifOutMulticastPkts_rate": null + }, + { + "port_descr_type": null, + "port_descr_descr": null, + "port_descr_circuit": null, + "port_descr_speed": null, + "port_descr_notes": null, + "ifDescr": "Device vmnic1 at 03:00.1 ntg3", + "ifName": "vmnic1", + "portName": null, + "ifIndex": 4, + "ifSpeed": null, + "ifSpeed_prev": null, + "ifConnectorPresent": null, + "ifPromiscuousMode": null, + "ifHighSpeed": null, + "ifHighSpeed_prev": null, + "ifOperStatus": "down", + "ifOperStatus_prev": null, + "ifAdminStatus": null, + "ifAdminStatus_prev": null, + "ifDuplex": null, + "ifMtu": null, + "ifType": "ethernetCsmacd", + "ifAlias": "03:00.1", + "ifPhysAddress": null, + "ifHardType": null, + "ifLastChange": 0, + "ifVlan": "", + "ifTrunk": null, + "counter_in": null, + "counter_out": null, + "ignore": 0, + "disabled": 0, + "detailed": 0, + "deleted": 0, + "pagpOperationMode": null, + "pagpPortState": null, + "pagpPartnerDeviceId": null, + "pagpPartnerLearnMethod": null, + "pagpPartnerIfIndex": null, + "pagpPartnerGroupIfIndex": null, + "pagpPartnerDeviceName": null, + "pagpEthcOperationMode": null, + "pagpDeviceId": null, + "pagpGroupIfIndex": null, + "ifInUcastPkts": null, + "ifInUcastPkts_prev": null, + "ifInUcastPkts_delta": null, + "ifInUcastPkts_rate": null, + "ifOutUcastPkts": null, + "ifOutUcastPkts_prev": null, + "ifOutUcastPkts_delta": null, + "ifOutUcastPkts_rate": null, + "ifInErrors": null, + "ifInErrors_prev": null, + "ifInErrors_delta": null, + "ifInErrors_rate": null, + "ifOutErrors": null, + "ifOutErrors_prev": null, + "ifOutErrors_delta": null, + "ifOutErrors_rate": null, + "ifInOctets": null, + "ifInOctets_prev": null, + "ifInOctets_delta": null, + "ifInOctets_rate": null, + "ifOutOctets": null, + "ifOutOctets_prev": null, + "ifOutOctets_delta": null, + "ifOutOctets_rate": null, + "poll_prev": null, + "ifInNUcastPkts": null, + "ifInNUcastPkts_prev": null, + "ifInNUcastPkts_delta": null, + "ifInNUcastPkts_rate": null, + "ifOutNUcastPkts": null, + "ifOutNUcastPkts_prev": null, + "ifOutNUcastPkts_delta": null, + "ifOutNUcastPkts_rate": null, + "ifInDiscards": null, + "ifInDiscards_prev": null, + "ifInDiscards_delta": null, + "ifInDiscards_rate": null, + "ifOutDiscards": null, + "ifOutDiscards_prev": null, + "ifOutDiscards_delta": null, + "ifOutDiscards_rate": null, + "ifInUnknownProtos": null, + "ifInUnknownProtos_prev": null, + "ifInUnknownProtos_delta": null, + "ifInUnknownProtos_rate": null, + "ifInBroadcastPkts": null, + "ifInBroadcastPkts_prev": null, + "ifInBroadcastPkts_delta": null, + "ifInBroadcastPkts_rate": null, + "ifOutBroadcastPkts": null, + "ifOutBroadcastPkts_prev": null, + "ifOutBroadcastPkts_delta": null, + "ifOutBroadcastPkts_rate": null, + "ifInMulticastPkts": null, + "ifInMulticastPkts_prev": null, + "ifInMulticastPkts_delta": null, + "ifInMulticastPkts_rate": null, + "ifOutMulticastPkts": null, + "ifOutMulticastPkts_prev": null, + "ifOutMulticastPkts_delta": null, + "ifOutMulticastPkts_rate": null + }, + { + "port_descr_type": null, + "port_descr_descr": null, + "port_descr_circuit": null, + "port_descr_speed": null, + "port_descr_notes": null, + "ifDescr": "Device vmnic2 at 03:00.2 ntg3", + "ifName": "vmnic2", + "portName": null, + "ifIndex": 5, + "ifSpeed": null, + "ifSpeed_prev": null, + "ifConnectorPresent": null, + "ifPromiscuousMode": null, + "ifHighSpeed": null, + "ifHighSpeed_prev": null, + "ifOperStatus": "down", + "ifOperStatus_prev": null, + "ifAdminStatus": null, + "ifAdminStatus_prev": null, + "ifDuplex": null, + "ifMtu": null, + "ifType": "ethernetCsmacd", + "ifAlias": "03:00.2", + "ifPhysAddress": null, + "ifHardType": null, + "ifLastChange": 0, + "ifVlan": "", + "ifTrunk": null, + "counter_in": null, + "counter_out": null, + "ignore": 0, + "disabled": 0, + "detailed": 0, + "deleted": 0, + "pagpOperationMode": null, + "pagpPortState": null, + "pagpPartnerDeviceId": null, + "pagpPartnerLearnMethod": null, + "pagpPartnerIfIndex": null, + "pagpPartnerGroupIfIndex": null, + "pagpPartnerDeviceName": null, + "pagpEthcOperationMode": null, + "pagpDeviceId": null, + "pagpGroupIfIndex": null, + "ifInUcastPkts": null, + "ifInUcastPkts_prev": null, + "ifInUcastPkts_delta": null, + "ifInUcastPkts_rate": null, + "ifOutUcastPkts": null, + "ifOutUcastPkts_prev": null, + "ifOutUcastPkts_delta": null, + "ifOutUcastPkts_rate": null, + "ifInErrors": null, + "ifInErrors_prev": null, + "ifInErrors_delta": null, + "ifInErrors_rate": null, + "ifOutErrors": null, + "ifOutErrors_prev": null, + "ifOutErrors_delta": null, + "ifOutErrors_rate": null, + "ifInOctets": null, + "ifInOctets_prev": null, + "ifInOctets_delta": null, + "ifInOctets_rate": null, + "ifOutOctets": null, + "ifOutOctets_prev": null, + "ifOutOctets_delta": null, + "ifOutOctets_rate": null, + "poll_prev": null, + "ifInNUcastPkts": null, + "ifInNUcastPkts_prev": null, + "ifInNUcastPkts_delta": null, + "ifInNUcastPkts_rate": null, + "ifOutNUcastPkts": null, + "ifOutNUcastPkts_prev": null, + "ifOutNUcastPkts_delta": null, + "ifOutNUcastPkts_rate": null, + "ifInDiscards": null, + "ifInDiscards_prev": null, + "ifInDiscards_delta": null, + "ifInDiscards_rate": null, + "ifOutDiscards": null, + "ifOutDiscards_prev": null, + "ifOutDiscards_delta": null, + "ifOutDiscards_rate": null, + "ifInUnknownProtos": null, + "ifInUnknownProtos_prev": null, + "ifInUnknownProtos_delta": null, + "ifInUnknownProtos_rate": null, + "ifInBroadcastPkts": null, + "ifInBroadcastPkts_prev": null, + "ifInBroadcastPkts_delta": null, + "ifInBroadcastPkts_rate": null, + "ifOutBroadcastPkts": null, + "ifOutBroadcastPkts_prev": null, + "ifOutBroadcastPkts_delta": null, + "ifOutBroadcastPkts_rate": null, + "ifInMulticastPkts": null, + "ifInMulticastPkts_prev": null, + "ifInMulticastPkts_delta": null, + "ifInMulticastPkts_rate": null, + "ifOutMulticastPkts": null, + "ifOutMulticastPkts_prev": null, + "ifOutMulticastPkts_delta": null, + "ifOutMulticastPkts_rate": null + }, + { + "port_descr_type": null, + "port_descr_descr": null, + "port_descr_circuit": null, + "port_descr_speed": null, + "port_descr_notes": null, + "ifDescr": "Device vmnic3 at 03:00.3 ntg3", + "ifName": "vmnic3", + "portName": null, + "ifIndex": 6, + "ifSpeed": null, + "ifSpeed_prev": null, + "ifConnectorPresent": null, + "ifPromiscuousMode": null, + "ifHighSpeed": null, + "ifHighSpeed_prev": null, + "ifOperStatus": "down", + "ifOperStatus_prev": null, + "ifAdminStatus": null, + "ifAdminStatus_prev": null, + "ifDuplex": null, + "ifMtu": null, + "ifType": "ethernetCsmacd", + "ifAlias": "03:00.3", + "ifPhysAddress": null, + "ifHardType": null, + "ifLastChange": 0, + "ifVlan": "", + "ifTrunk": null, + "counter_in": null, + "counter_out": null, + "ignore": 0, + "disabled": 0, + "detailed": 0, + "deleted": 0, + "pagpOperationMode": null, + "pagpPortState": null, + "pagpPartnerDeviceId": null, + "pagpPartnerLearnMethod": null, + "pagpPartnerIfIndex": null, + "pagpPartnerGroupIfIndex": null, + "pagpPartnerDeviceName": null, + "pagpEthcOperationMode": null, + "pagpDeviceId": null, + "pagpGroupIfIndex": null, + "ifInUcastPkts": null, + "ifInUcastPkts_prev": null, + "ifInUcastPkts_delta": null, + "ifInUcastPkts_rate": null, + "ifOutUcastPkts": null, + "ifOutUcastPkts_prev": null, + "ifOutUcastPkts_delta": null, + "ifOutUcastPkts_rate": null, + "ifInErrors": null, + "ifInErrors_prev": null, + "ifInErrors_delta": null, + "ifInErrors_rate": null, + "ifOutErrors": null, + "ifOutErrors_prev": null, + "ifOutErrors_delta": null, + "ifOutErrors_rate": null, + "ifInOctets": null, + "ifInOctets_prev": null, + "ifInOctets_delta": null, + "ifInOctets_rate": null, + "ifOutOctets": null, + "ifOutOctets_prev": null, + "ifOutOctets_delta": null, + "ifOutOctets_rate": null, + "poll_prev": null, + "ifInNUcastPkts": null, + "ifInNUcastPkts_prev": null, + "ifInNUcastPkts_delta": null, + "ifInNUcastPkts_rate": null, + "ifOutNUcastPkts": null, + "ifOutNUcastPkts_prev": null, + "ifOutNUcastPkts_delta": null, + "ifOutNUcastPkts_rate": null, + "ifInDiscards": null, + "ifInDiscards_prev": null, + "ifInDiscards_delta": null, + "ifInDiscards_rate": null, + "ifOutDiscards": null, + "ifOutDiscards_prev": null, + "ifOutDiscards_delta": null, + "ifOutDiscards_rate": null, + "ifInUnknownProtos": null, + "ifInUnknownProtos_prev": null, + "ifInUnknownProtos_delta": null, + "ifInUnknownProtos_rate": null, + "ifInBroadcastPkts": null, + "ifInBroadcastPkts_prev": null, + "ifInBroadcastPkts_delta": null, + "ifInBroadcastPkts_rate": null, + "ifOutBroadcastPkts": null, + "ifOutBroadcastPkts_prev": null, + "ifOutBroadcastPkts_delta": null, + "ifOutBroadcastPkts_rate": null, + "ifInMulticastPkts": null, + "ifInMulticastPkts_prev": null, + "ifInMulticastPkts_delta": null, + "ifInMulticastPkts_rate": null, + "ifOutMulticastPkts": null, + "ifOutMulticastPkts_prev": null, + "ifOutMulticastPkts_delta": null, + "ifOutMulticastPkts_rate": null + } + ] + }, + "poller": { + "ports": [ + { + "port_descr_type": "07", + "port_descr_descr": "00.0", + "port_descr_circuit": null, + "port_descr_speed": null, + "port_descr_notes": null, + "ifDescr": "vmnic4", + "ifName": "vmnic4", + "portName": null, + "ifIndex": 1, + "ifSpeed": 10000000000, + "ifSpeed_prev": null, + "ifConnectorPresent": "true", + "ifPromiscuousMode": "true", + "ifHighSpeed": 10000, + "ifHighSpeed_prev": null, + "ifOperStatus": "up", + "ifOperStatus_prev": "up", + "ifAdminStatus": "up", + "ifAdminStatus_prev": null, + "ifDuplex": null, + "ifMtu": 9000, + "ifType": "ethernetCsmacd", + "ifAlias": "07:00.0", + "ifPhysAddress": "3cfdfebcea3c", + "ifHardType": null, + "ifLastChange": 0, + "ifVlan": "", + "ifTrunk": null, + "counter_in": null, + "counter_out": null, + "ignore": 0, + "disabled": 0, + "detailed": 0, + "deleted": 0, + "pagpOperationMode": null, + "pagpPortState": null, + "pagpPartnerDeviceId": null, + "pagpPartnerLearnMethod": null, + "pagpPartnerIfIndex": null, + "pagpPartnerGroupIfIndex": null, + "pagpPartnerDeviceName": null, + "pagpEthcOperationMode": null, + "pagpDeviceId": null, + "pagpGroupIfIndex": null, + "ifInUcastPkts": 0, + "ifInUcastPkts_prev": 0, + "ifInUcastPkts_delta": null, + "ifInUcastPkts_rate": null, + "ifOutUcastPkts": 0, + "ifOutUcastPkts_prev": 0, + "ifOutUcastPkts_delta": null, + "ifOutUcastPkts_rate": null, + "ifInErrors": 0, + "ifInErrors_prev": 0, + "ifInErrors_delta": null, + "ifInErrors_rate": null, + "ifOutErrors": 0, + "ifOutErrors_prev": 0, + "ifOutErrors_delta": null, + "ifOutErrors_rate": null, + "ifInOctets": 233481089086071, + "ifInOctets_prev": 0, + "ifInOctets_delta": null, + "ifInOctets_rate": null, + "ifOutOctets": 114246316241540, + "ifOutOctets_prev": 0, + "ifOutOctets_delta": null, + "ifOutOctets_rate": null, + "poll_prev": null, + "ifInNUcastPkts": 0, + "ifInNUcastPkts_prev": 0, + "ifInNUcastPkts_delta": null, + "ifInNUcastPkts_rate": null, + "ifOutNUcastPkts": 0, + "ifOutNUcastPkts_prev": 0, + "ifOutNUcastPkts_delta": null, + "ifOutNUcastPkts_rate": null, + "ifInDiscards": 0, + "ifInDiscards_prev": 0, + "ifInDiscards_delta": null, + "ifInDiscards_rate": null, + "ifOutDiscards": 0, + "ifOutDiscards_prev": 0, + "ifOutDiscards_delta": null, + "ifOutDiscards_rate": null, + "ifInUnknownProtos": 0, + "ifInUnknownProtos_prev": 0, + "ifInUnknownProtos_delta": null, + "ifInUnknownProtos_rate": null, + "ifInBroadcastPkts": 0, + "ifInBroadcastPkts_prev": 0, + "ifInBroadcastPkts_delta": null, + "ifInBroadcastPkts_rate": null, + "ifOutBroadcastPkts": 0, + "ifOutBroadcastPkts_prev": 0, + "ifOutBroadcastPkts_delta": null, + "ifOutBroadcastPkts_rate": null, + "ifInMulticastPkts": 0, + "ifInMulticastPkts_prev": 0, + "ifInMulticastPkts_delta": null, + "ifInMulticastPkts_rate": null, + "ifOutMulticastPkts": 0, + "ifOutMulticastPkts_prev": 0, + "ifOutMulticastPkts_delta": null, + "ifOutMulticastPkts_rate": null + }, + { + "port_descr_type": "07", + "port_descr_descr": "00.1", + "port_descr_circuit": null, + "port_descr_speed": null, + "port_descr_notes": null, + "ifDescr": "vmnic5", + "ifName": "vmnic5", + "portName": null, + "ifIndex": 2, + "ifSpeed": 10000000000, + "ifSpeed_prev": null, + "ifConnectorPresent": "true", + "ifPromiscuousMode": "true", + "ifHighSpeed": 10000, + "ifHighSpeed_prev": null, + "ifOperStatus": "up", + "ifOperStatus_prev": "up", + "ifAdminStatus": "up", + "ifAdminStatus_prev": null, + "ifDuplex": null, + "ifMtu": 9000, + "ifType": "ethernetCsmacd", + "ifAlias": "07:00.1", + "ifPhysAddress": "3cfdfebcea3d", + "ifHardType": null, + "ifLastChange": 0, + "ifVlan": "", + "ifTrunk": null, + "counter_in": null, + "counter_out": null, + "ignore": 0, + "disabled": 0, + "detailed": 0, + "deleted": 0, + "pagpOperationMode": null, + "pagpPortState": null, + "pagpPartnerDeviceId": null, + "pagpPartnerLearnMethod": null, + "pagpPartnerIfIndex": null, + "pagpPartnerGroupIfIndex": null, + "pagpPartnerDeviceName": null, + "pagpEthcOperationMode": null, + "pagpDeviceId": null, + "pagpGroupIfIndex": null, + "ifInUcastPkts": 0, + "ifInUcastPkts_prev": 0, + "ifInUcastPkts_delta": null, + "ifInUcastPkts_rate": null, + "ifOutUcastPkts": 0, + "ifOutUcastPkts_prev": 0, + "ifOutUcastPkts_delta": null, + "ifOutUcastPkts_rate": null, + "ifInErrors": 0, + "ifInErrors_prev": 0, + "ifInErrors_delta": null, + "ifInErrors_rate": null, + "ifOutErrors": 0, + "ifOutErrors_prev": 0, + "ifOutErrors_delta": null, + "ifOutErrors_rate": null, + "ifInOctets": 100828535445858, + "ifInOctets_prev": 0, + "ifInOctets_delta": null, + "ifInOctets_rate": null, + "ifOutOctets": 68674682590179, + "ifOutOctets_prev": 0, + "ifOutOctets_delta": null, + "ifOutOctets_rate": null, + "poll_prev": null, + "ifInNUcastPkts": 0, + "ifInNUcastPkts_prev": 0, + "ifInNUcastPkts_delta": null, + "ifInNUcastPkts_rate": null, + "ifOutNUcastPkts": 0, + "ifOutNUcastPkts_prev": 0, + "ifOutNUcastPkts_delta": null, + "ifOutNUcastPkts_rate": null, + "ifInDiscards": 0, + "ifInDiscards_prev": 0, + "ifInDiscards_delta": null, + "ifInDiscards_rate": null, + "ifOutDiscards": 0, + "ifOutDiscards_prev": 0, + "ifOutDiscards_delta": null, + "ifOutDiscards_rate": null, + "ifInUnknownProtos": 0, + "ifInUnknownProtos_prev": 0, + "ifInUnknownProtos_delta": null, + "ifInUnknownProtos_rate": null, + "ifInBroadcastPkts": 0, + "ifInBroadcastPkts_prev": 0, + "ifInBroadcastPkts_delta": null, + "ifInBroadcastPkts_rate": null, + "ifOutBroadcastPkts": 0, + "ifOutBroadcastPkts_prev": 0, + "ifOutBroadcastPkts_delta": null, + "ifOutBroadcastPkts_rate": null, + "ifInMulticastPkts": 0, + "ifInMulticastPkts_prev": 0, + "ifInMulticastPkts_delta": null, + "ifInMulticastPkts_rate": null, + "ifOutMulticastPkts": 0, + "ifOutMulticastPkts_prev": 0, + "ifOutMulticastPkts_delta": null, + "ifOutMulticastPkts_rate": null + }, + { + "port_descr_type": "03", + "port_descr_descr": "00.0", + "port_descr_circuit": null, + "port_descr_speed": null, + "port_descr_notes": null, + "ifDescr": "vmnic0", + "ifName": "vmnic0", + "portName": null, + "ifIndex": 3, + "ifSpeed": null, + "ifSpeed_prev": 0, + "ifConnectorPresent": "true", + "ifPromiscuousMode": "true", + "ifHighSpeed": 0, + "ifHighSpeed_prev": null, + "ifOperStatus": "down", + "ifOperStatus_prev": "down", + "ifAdminStatus": "up", + "ifAdminStatus_prev": null, + "ifDuplex": null, + "ifMtu": 1500, + "ifType": "ethernetCsmacd", + "ifAlias": "03:00.0", + "ifPhysAddress": "ac162d8c3d68", + "ifHardType": null, + "ifLastChange": 0, + "ifVlan": "", + "ifTrunk": null, + "counter_in": null, + "counter_out": null, + "ignore": 0, + "disabled": 0, + "detailed": 0, + "deleted": 0, + "pagpOperationMode": null, + "pagpPortState": null, + "pagpPartnerDeviceId": null, + "pagpPartnerLearnMethod": null, + "pagpPartnerIfIndex": null, + "pagpPartnerGroupIfIndex": null, + "pagpPartnerDeviceName": null, + "pagpEthcOperationMode": null, + "pagpDeviceId": null, + "pagpGroupIfIndex": null, + "ifInUcastPkts": 0, + "ifInUcastPkts_prev": 0, + "ifInUcastPkts_delta": null, + "ifInUcastPkts_rate": null, + "ifOutUcastPkts": 0, + "ifOutUcastPkts_prev": 0, + "ifOutUcastPkts_delta": null, + "ifOutUcastPkts_rate": null, + "ifInErrors": 0, + "ifInErrors_prev": 0, + "ifInErrors_delta": null, + "ifInErrors_rate": null, + "ifOutErrors": 0, + "ifOutErrors_prev": 0, + "ifOutErrors_delta": null, + "ifOutErrors_rate": null, + "ifInOctets": 0, + "ifInOctets_prev": 0, + "ifInOctets_delta": null, + "ifInOctets_rate": null, + "ifOutOctets": 0, + "ifOutOctets_prev": 0, + "ifOutOctets_delta": null, + "ifOutOctets_rate": null, + "poll_prev": null, + "ifInNUcastPkts": 0, + "ifInNUcastPkts_prev": 0, + "ifInNUcastPkts_delta": null, + "ifInNUcastPkts_rate": null, + "ifOutNUcastPkts": 0, + "ifOutNUcastPkts_prev": 0, + "ifOutNUcastPkts_delta": null, + "ifOutNUcastPkts_rate": null, + "ifInDiscards": 0, + "ifInDiscards_prev": 0, + "ifInDiscards_delta": null, + "ifInDiscards_rate": null, + "ifOutDiscards": 0, + "ifOutDiscards_prev": 0, + "ifOutDiscards_delta": null, + "ifOutDiscards_rate": null, + "ifInUnknownProtos": 0, + "ifInUnknownProtos_prev": 0, + "ifInUnknownProtos_delta": null, + "ifInUnknownProtos_rate": null, + "ifInBroadcastPkts": 0, + "ifInBroadcastPkts_prev": 0, + "ifInBroadcastPkts_delta": null, + "ifInBroadcastPkts_rate": null, + "ifOutBroadcastPkts": 0, + "ifOutBroadcastPkts_prev": 0, + "ifOutBroadcastPkts_delta": null, + "ifOutBroadcastPkts_rate": null, + "ifInMulticastPkts": 0, + "ifInMulticastPkts_prev": 0, + "ifInMulticastPkts_delta": null, + "ifInMulticastPkts_rate": null, + "ifOutMulticastPkts": 0, + "ifOutMulticastPkts_prev": 0, + "ifOutMulticastPkts_delta": null, + "ifOutMulticastPkts_rate": null + }, + { + "port_descr_type": "03", + "port_descr_descr": "00.1", + "port_descr_circuit": null, + "port_descr_speed": null, + "port_descr_notes": null, + "ifDescr": "vmnic1", + "ifName": "vmnic1", + "portName": null, + "ifIndex": 4, + "ifSpeed": null, + "ifSpeed_prev": 0, + "ifConnectorPresent": "true", + "ifPromiscuousMode": "true", + "ifHighSpeed": 0, + "ifHighSpeed_prev": null, + "ifOperStatus": "down", + "ifOperStatus_prev": "down", + "ifAdminStatus": "up", + "ifAdminStatus_prev": null, + "ifDuplex": null, + "ifMtu": 1500, + "ifType": "ethernetCsmacd", + "ifAlias": "03:00.1", + "ifPhysAddress": "ac162d8c3d69", + "ifHardType": null, + "ifLastChange": 0, + "ifVlan": "", + "ifTrunk": null, + "counter_in": null, + "counter_out": null, + "ignore": 0, + "disabled": 0, + "detailed": 0, + "deleted": 0, + "pagpOperationMode": null, + "pagpPortState": null, + "pagpPartnerDeviceId": null, + "pagpPartnerLearnMethod": null, + "pagpPartnerIfIndex": null, + "pagpPartnerGroupIfIndex": null, + "pagpPartnerDeviceName": null, + "pagpEthcOperationMode": null, + "pagpDeviceId": null, + "pagpGroupIfIndex": null, + "ifInUcastPkts": 0, + "ifInUcastPkts_prev": 0, + "ifInUcastPkts_delta": null, + "ifInUcastPkts_rate": null, + "ifOutUcastPkts": 0, + "ifOutUcastPkts_prev": 0, + "ifOutUcastPkts_delta": null, + "ifOutUcastPkts_rate": null, + "ifInErrors": 0, + "ifInErrors_prev": 0, + "ifInErrors_delta": null, + "ifInErrors_rate": null, + "ifOutErrors": 0, + "ifOutErrors_prev": 0, + "ifOutErrors_delta": null, + "ifOutErrors_rate": null, + "ifInOctets": 0, + "ifInOctets_prev": 0, + "ifInOctets_delta": null, + "ifInOctets_rate": null, + "ifOutOctets": 0, + "ifOutOctets_prev": 0, + "ifOutOctets_delta": null, + "ifOutOctets_rate": null, + "poll_prev": null, + "ifInNUcastPkts": 0, + "ifInNUcastPkts_prev": 0, + "ifInNUcastPkts_delta": null, + "ifInNUcastPkts_rate": null, + "ifOutNUcastPkts": 0, + "ifOutNUcastPkts_prev": 0, + "ifOutNUcastPkts_delta": null, + "ifOutNUcastPkts_rate": null, + "ifInDiscards": 0, + "ifInDiscards_prev": 0, + "ifInDiscards_delta": null, + "ifInDiscards_rate": null, + "ifOutDiscards": 0, + "ifOutDiscards_prev": 0, + "ifOutDiscards_delta": null, + "ifOutDiscards_rate": null, + "ifInUnknownProtos": 0, + "ifInUnknownProtos_prev": 0, + "ifInUnknownProtos_delta": null, + "ifInUnknownProtos_rate": null, + "ifInBroadcastPkts": 0, + "ifInBroadcastPkts_prev": 0, + "ifInBroadcastPkts_delta": null, + "ifInBroadcastPkts_rate": null, + "ifOutBroadcastPkts": 0, + "ifOutBroadcastPkts_prev": 0, + "ifOutBroadcastPkts_delta": null, + "ifOutBroadcastPkts_rate": null, + "ifInMulticastPkts": 0, + "ifInMulticastPkts_prev": 0, + "ifInMulticastPkts_delta": null, + "ifInMulticastPkts_rate": null, + "ifOutMulticastPkts": 0, + "ifOutMulticastPkts_prev": 0, + "ifOutMulticastPkts_delta": null, + "ifOutMulticastPkts_rate": null + }, + { + "port_descr_type": "03", + "port_descr_descr": "00.2", + "port_descr_circuit": null, + "port_descr_speed": null, + "port_descr_notes": null, + "ifDescr": "vmnic2", + "ifName": "vmnic2", + "portName": null, + "ifIndex": 5, + "ifSpeed": null, + "ifSpeed_prev": 0, + "ifConnectorPresent": "true", + "ifPromiscuousMode": "true", + "ifHighSpeed": 0, + "ifHighSpeed_prev": null, + "ifOperStatus": "down", + "ifOperStatus_prev": "down", + "ifAdminStatus": "up", + "ifAdminStatus_prev": null, + "ifDuplex": null, + "ifMtu": 1500, + "ifType": "ethernetCsmacd", + "ifAlias": "03:00.2", + "ifPhysAddress": "ac162d8c3d6a", + "ifHardType": null, + "ifLastChange": 0, + "ifVlan": "", + "ifTrunk": null, + "counter_in": null, + "counter_out": null, + "ignore": 0, + "disabled": 0, + "detailed": 0, + "deleted": 0, + "pagpOperationMode": null, + "pagpPortState": null, + "pagpPartnerDeviceId": null, + "pagpPartnerLearnMethod": null, + "pagpPartnerIfIndex": null, + "pagpPartnerGroupIfIndex": null, + "pagpPartnerDeviceName": null, + "pagpEthcOperationMode": null, + "pagpDeviceId": null, + "pagpGroupIfIndex": null, + "ifInUcastPkts": 0, + "ifInUcastPkts_prev": 0, + "ifInUcastPkts_delta": null, + "ifInUcastPkts_rate": null, + "ifOutUcastPkts": 0, + "ifOutUcastPkts_prev": 0, + "ifOutUcastPkts_delta": null, + "ifOutUcastPkts_rate": null, + "ifInErrors": 0, + "ifInErrors_prev": 0, + "ifInErrors_delta": null, + "ifInErrors_rate": null, + "ifOutErrors": 0, + "ifOutErrors_prev": 0, + "ifOutErrors_delta": null, + "ifOutErrors_rate": null, + "ifInOctets": 0, + "ifInOctets_prev": 0, + "ifInOctets_delta": null, + "ifInOctets_rate": null, + "ifOutOctets": 0, + "ifOutOctets_prev": 0, + "ifOutOctets_delta": null, + "ifOutOctets_rate": null, + "poll_prev": null, + "ifInNUcastPkts": 0, + "ifInNUcastPkts_prev": 0, + "ifInNUcastPkts_delta": null, + "ifInNUcastPkts_rate": null, + "ifOutNUcastPkts": 0, + "ifOutNUcastPkts_prev": 0, + "ifOutNUcastPkts_delta": null, + "ifOutNUcastPkts_rate": null, + "ifInDiscards": 0, + "ifInDiscards_prev": 0, + "ifInDiscards_delta": null, + "ifInDiscards_rate": null, + "ifOutDiscards": 0, + "ifOutDiscards_prev": 0, + "ifOutDiscards_delta": null, + "ifOutDiscards_rate": null, + "ifInUnknownProtos": 0, + "ifInUnknownProtos_prev": 0, + "ifInUnknownProtos_delta": null, + "ifInUnknownProtos_rate": null, + "ifInBroadcastPkts": 0, + "ifInBroadcastPkts_prev": 0, + "ifInBroadcastPkts_delta": null, + "ifInBroadcastPkts_rate": null, + "ifOutBroadcastPkts": 0, + "ifOutBroadcastPkts_prev": 0, + "ifOutBroadcastPkts_delta": null, + "ifOutBroadcastPkts_rate": null, + "ifInMulticastPkts": 0, + "ifInMulticastPkts_prev": 0, + "ifInMulticastPkts_delta": null, + "ifInMulticastPkts_rate": null, + "ifOutMulticastPkts": 0, + "ifOutMulticastPkts_prev": 0, + "ifOutMulticastPkts_delta": null, + "ifOutMulticastPkts_rate": null + }, + { + "port_descr_type": "03", + "port_descr_descr": "00.3", + "port_descr_circuit": null, + "port_descr_speed": null, + "port_descr_notes": null, + "ifDescr": "vmnic3", + "ifName": "vmnic3", + "portName": null, + "ifIndex": 6, + "ifSpeed": null, + "ifSpeed_prev": 0, + "ifConnectorPresent": "true", + "ifPromiscuousMode": "true", + "ifHighSpeed": 0, + "ifHighSpeed_prev": null, + "ifOperStatus": "down", + "ifOperStatus_prev": "down", + "ifAdminStatus": "up", + "ifAdminStatus_prev": null, + "ifDuplex": null, + "ifMtu": 1500, + "ifType": "ethernetCsmacd", + "ifAlias": "03:00.3", + "ifPhysAddress": "ac162d8c3d6b", + "ifHardType": null, + "ifLastChange": 0, + "ifVlan": "", + "ifTrunk": null, + "counter_in": null, + "counter_out": null, + "ignore": 0, + "disabled": 0, + "detailed": 0, + "deleted": 0, + "pagpOperationMode": null, + "pagpPortState": null, + "pagpPartnerDeviceId": null, + "pagpPartnerLearnMethod": null, + "pagpPartnerIfIndex": null, + "pagpPartnerGroupIfIndex": null, + "pagpPartnerDeviceName": null, + "pagpEthcOperationMode": null, + "pagpDeviceId": null, + "pagpGroupIfIndex": null, + "ifInUcastPkts": 0, + "ifInUcastPkts_prev": 0, + "ifInUcastPkts_delta": null, + "ifInUcastPkts_rate": null, + "ifOutUcastPkts": 0, + "ifOutUcastPkts_prev": 0, + "ifOutUcastPkts_delta": null, + "ifOutUcastPkts_rate": null, + "ifInErrors": 0, + "ifInErrors_prev": 0, + "ifInErrors_delta": null, + "ifInErrors_rate": null, + "ifOutErrors": 0, + "ifOutErrors_prev": 0, + "ifOutErrors_delta": null, + "ifOutErrors_rate": null, + "ifInOctets": 0, + "ifInOctets_prev": 0, + "ifInOctets_delta": null, + "ifInOctets_rate": null, + "ifOutOctets": 0, + "ifOutOctets_prev": 0, + "ifOutOctets_delta": null, + "ifOutOctets_rate": null, + "poll_prev": null, + "ifInNUcastPkts": 0, + "ifInNUcastPkts_prev": 0, + "ifInNUcastPkts_delta": null, + "ifInNUcastPkts_rate": null, + "ifOutNUcastPkts": 0, + "ifOutNUcastPkts_prev": 0, + "ifOutNUcastPkts_delta": null, + "ifOutNUcastPkts_rate": null, + "ifInDiscards": 0, + "ifInDiscards_prev": 0, + "ifInDiscards_delta": null, + "ifInDiscards_rate": null, + "ifOutDiscards": 0, + "ifOutDiscards_prev": 0, + "ifOutDiscards_delta": null, + "ifOutDiscards_rate": null, + "ifInUnknownProtos": 0, + "ifInUnknownProtos_prev": 0, + "ifInUnknownProtos_delta": null, + "ifInUnknownProtos_rate": null, + "ifInBroadcastPkts": 0, + "ifInBroadcastPkts_prev": 0, + "ifInBroadcastPkts_delta": null, + "ifInBroadcastPkts_rate": null, + "ifOutBroadcastPkts": 0, + "ifOutBroadcastPkts_prev": 0, + "ifOutBroadcastPkts_delta": null, + "ifOutBroadcastPkts_rate": null, + "ifInMulticastPkts": 0, + "ifInMulticastPkts_prev": 0, + "ifInMulticastPkts_delta": null, + "ifInMulticastPkts_rate": null, + "ifOutMulticastPkts": 0, + "ifOutMulticastPkts_prev": 0, + "ifOutMulticastPkts_delta": null, + "ifOutMulticastPkts_rate": null + } + ] + } + }, + "processors": { + "discovery": { + "processors": [ + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 1, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.1", + "processor_index": "1", + "processor_type": "hr", + "processor_usage": 23, + "processor_descr": "Pkg/ID/Node: 0/0/0 Intel Xeon E5-2650 0 @ 2.00GHz", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 2, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.2", + "processor_index": "2", + "processor_type": "hr", + "processor_usage": 23, + "processor_descr": "Pkg/ID/Node: 0/1/0 Intel Xeon E5-2650 0 @ 2.00GHz", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 3, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.3", + "processor_index": "3", + "processor_type": "hr", + "processor_usage": 23, + "processor_descr": "Pkg/ID/Node: 0/2/0 Intel Xeon E5-2650 0 @ 2.00GHz", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 4, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.4", + "processor_index": "4", + "processor_type": "hr", + "processor_usage": 19, + "processor_descr": "Pkg/ID/Node: 0/3/0 Intel Xeon E5-2650 0 @ 2.00GHz", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 5, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.5", + "processor_index": "5", + "processor_type": "hr", + "processor_usage": 20, + "processor_descr": "Pkg/ID/Node: 0/4/0 Intel Xeon E5-2650 0 @ 2.00GHz", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 6, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.6", + "processor_index": "6", + "processor_type": "hr", + "processor_usage": 21, + "processor_descr": "Pkg/ID/Node: 0/5/0 Intel Xeon E5-2650 0 @ 2.00GHz", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 7, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.7", + "processor_index": "7", + "processor_type": "hr", + "processor_usage": 28, + "processor_descr": "Pkg/ID/Node: 0/6/0 Intel Xeon E5-2650 0 @ 2.00GHz", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 8, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.8", + "processor_index": "8", + "processor_type": "hr", + "processor_usage": 16, + "processor_descr": "Pkg/ID/Node: 0/7/0 Intel Xeon E5-2650 0 @ 2.00GHz", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 9, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.9", + "processor_index": "9", + "processor_type": "hr", + "processor_usage": 24, + "processor_descr": "Pkg/ID/Node: 0/8/0 Intel Xeon E5-2650 0 @ 2.00GHz", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 10, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.10", + "processor_index": "10", + "processor_type": "hr", + "processor_usage": 17, + "processor_descr": "Pkg/ID/Node: 0/9/0 Intel Xeon E5-2650 0 @ 2.00GHz", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 11, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.11", + "processor_index": "11", + "processor_type": "hr", + "processor_usage": 3, + "processor_descr": "Pkg/ID/Node: 0/10/0 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 12, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.12", + "processor_index": "12", + "processor_type": "hr", + "processor_usage": 24, + "processor_descr": "Pkg/ID/Node: 0/11/0 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 13, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.13", + "processor_index": "13", + "processor_type": "hr", + "processor_usage": 17, + "processor_descr": "Pkg/ID/Node: 0/12/0 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 14, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.14", + "processor_index": "14", + "processor_type": "hr", + "processor_usage": 10, + "processor_descr": "Pkg/ID/Node: 0/13/0 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 15, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.15", + "processor_index": "15", + "processor_type": "hr", + "processor_usage": 11, + "processor_descr": "Pkg/ID/Node: 0/14/0 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 16, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.16", + "processor_index": "16", + "processor_type": "hr", + "processor_usage": 23, + "processor_descr": "Pkg/ID/Node: 0/15/0 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 17, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.17", + "processor_index": "17", + "processor_type": "hr", + "processor_usage": 10, + "processor_descr": "Pkg/ID/Node: 1/16/1 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 18, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.18", + "processor_index": "18", + "processor_type": "hr", + "processor_usage": 7, + "processor_descr": "Pkg/ID/Node: 1/17/1 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 19, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.19", + "processor_index": "19", + "processor_type": "hr", + "processor_usage": 10, + "processor_descr": "Pkg/ID/Node: 1/18/1 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 20, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.20", + "processor_index": "20", + "processor_type": "hr", + "processor_usage": 13, + "processor_descr": "Pkg/ID/Node: 1/19/1 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 21, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.21", + "processor_index": "21", + "processor_type": "hr", + "processor_usage": 3, + "processor_descr": "Pkg/ID/Node: 1/20/1 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 22, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.22", + "processor_index": "22", + "processor_type": "hr", + "processor_usage": 3, + "processor_descr": "Pkg/ID/Node: 1/21/1 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 23, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.23", + "processor_index": "23", + "processor_type": "hr", + "processor_usage": 9, + "processor_descr": "Pkg/ID/Node: 1/22/1 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 24, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.24", + "processor_index": "24", + "processor_type": "hr", + "processor_usage": 8, + "processor_descr": "Pkg/ID/Node: 1/23/1 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 25, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.25", + "processor_index": "25", + "processor_type": "hr", + "processor_usage": 6, + "processor_descr": "Pkg/ID/Node: 1/24/1 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 26, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.26", + "processor_index": "26", + "processor_type": "hr", + "processor_usage": 3, + "processor_descr": "Pkg/ID/Node: 1/25/1 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 27, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.27", + "processor_index": "27", + "processor_type": "hr", + "processor_usage": 8, + "processor_descr": "Pkg/ID/Node: 1/26/1 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 28, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.28", + "processor_index": "28", + "processor_type": "hr", + "processor_usage": 3, + "processor_descr": "Pkg/ID/Node: 1/27/1 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 29, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.29", + "processor_index": "29", + "processor_type": "hr", + "processor_usage": 3, + "processor_descr": "Pkg/ID/Node: 1/28/1 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 30, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.30", + "processor_index": "30", + "processor_type": "hr", + "processor_usage": 10, + "processor_descr": "Pkg/ID/Node: 1/29/1 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 31, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.31", + "processor_index": "31", + "processor_type": "hr", + "processor_usage": 8, + "processor_descr": "Pkg/ID/Node: 1/30/1 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 32, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.32", + "processor_index": "32", + "processor_type": "hr", + "processor_usage": 9, + "processor_descr": "Pkg/ID/Node: 1/31/1 Intel Xeon E5-2650 0 @ 2.00GH", + "processor_precision": 1, + "processor_perc_warn": 75 + } + ] + }, + "poller": "matches discovery" + }, + "mempools": { + "discovery": { + "mempools": [ + { + "mempool_index": "9", + "entPhysicalIndex": null, + "hrDeviceIndex": null, + "mempool_type": "hrstorage", + "mempool_precision": 1024, + "mempool_descr": "Real Memory", + "mempool_perc": 0, + "mempool_used": 0, + "mempool_free": 0, + "mempool_total": 0, + "mempool_largestfree": null, + "mempool_lowestfree": null, + "mempool_deleted": 0, + "mempool_perc_warn": 99 + } + ] + }, + "poller": { + "mempools": [ + { + "mempool_index": "9", + "entPhysicalIndex": null, + "hrDeviceIndex": null, + "mempool_type": "hrstorage", + "mempool_precision": 1024, + "mempool_descr": "Real Memory", + "mempool_perc": 49, + "mempool_used": 100664401920, + "mempool_free": 105457549312, + "mempool_total": 206121951232, + "mempool_largestfree": null, + "mempool_lowestfree": null, + "mempool_deleted": 0, + "mempool_perc_warn": 99 + } + ] + } + }, + "storage": { + "discovery": { + "storage": [ + { + "storage_mib": "hrstorage", + "storage_index": "1", + "storage_type": "hrStorageRamDisk", + "storage_descr": "/vmfs/volumes/42e40393-eb4009d5-1981-5d539017033c", + "storage_size": 524009472, + "storage_units": 8192, + "storage_used": 177864704, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "2", + "storage_type": "hrStorageRamDisk", + "storage_descr": "/vmfs/volumes/5ea85958-f3cc2304-6482-3cfdfebcea3c", + "storage_size": 524009472, + "storage_units": 8192, + "storage_used": 177872896, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "3", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/vmfs/volumes/5c18205f-7fb22b14-d42f-3cfdfebcea3c", + "storage_size": 291789340672, + "storage_units": 1048576, + "storage_used": 4664066048, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "4", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/vmfs/volumes/5ea85a96-a262cce2-8120-3cfdfebcea3c", + "storage_size": 6710886400, + "storage_units": 1048576, + "storage_used": 1861222400, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "7", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/vmfs/volumes/7c6de8dc-33a02fdb-0000-000000000000", + "storage_size": 36003730423808, + "storage_units": 32768, + "storage_used": 13390408351744, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "8", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/vmfs/volumes/c08a74ec-a07bfa75-0000-000000000000", + "storage_size": 36003730423808, + "storage_units": 32768, + "storage_used": 13390408351744, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + } + ] + }, + "poller": { + "storage": [ + { + "storage_mib": "hrstorage", + "storage_index": "1", + "storage_type": "hrStorageRamDisk", + "storage_descr": "/vmfs/volumes/42e40393-eb4009d5-1981-5d539017033c", + "storage_size": 524009472, + "storage_units": 8192, + "storage_used": 177864704, + "storage_free": 346144768, + "storage_perc": 34, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "2", + "storage_type": "hrStorageRamDisk", + "storage_descr": "/vmfs/volumes/5ea85958-f3cc2304-6482-3cfdfebcea3c", + "storage_size": 524009472, + "storage_units": 8192, + "storage_used": 177872896, + "storage_free": 346136576, + "storage_perc": 34, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "3", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/vmfs/volumes/5c18205f-7fb22b14-d42f-3cfdfebcea3c", + "storage_size": 291789340672, + "storage_units": 1048576, + "storage_used": 4664066048, + "storage_free": 287125274624, + "storage_perc": 2, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "4", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/vmfs/volumes/5ea85a96-a262cce2-8120-3cfdfebcea3c", + "storage_size": 6710886400, + "storage_units": 1048576, + "storage_used": 1861222400, + "storage_free": 4849664000, + "storage_perc": 28, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "7", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/vmfs/volumes/7c6de8dc-33a02fdb-0000-000000000000", + "storage_size": 36003730423808, + "storage_units": 32768, + "storage_used": 13390408351744, + "storage_free": 22613322072064, + "storage_perc": 37, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "8", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/vmfs/volumes/c08a74ec-a07bfa75-0000-000000000000", + "storage_size": 36003730423808, + "storage_units": 32768, + "storage_used": 13390408351744, + "storage_free": 22613322072064, + "storage_perc": 37, + "storage_perc_warn": 60, + "storage_deleted": 0 + } + ] + } + } +} diff --git a/tests/data/vmware-vcsa.json b/tests/data/vmware-vcsa.json new file mode 100644 index 0000000000..a13cb7fe66 --- /dev/null +++ b/tests/data/vmware-vcsa.json @@ -0,0 +1,823 @@ +{ + "os": { + "discovery": { + "devices": [ + { + "sysName": "", + "sysObjectID": ".1.3.6.1.4.1.6876.4.6", + "sysDescr": "VMware-vCenter-Server-Appliance 7.0.0.10100 generic build 16386292 VMware, Inc. x86_64", + "sysContact": null, + "version": "7.0.0.10100", + "hardware": null, + "features": "build 16386292", + "os": "vmware-vcsa", + "type": "server", + "serial": null, + "icon": "vmware.svg", + "location": "" + } + ] + }, + "poller": { + "devices": [ + { + "sysName": "", + "sysObjectID": ".1.3.6.1.4.1.6876.4.6", + "sysDescr": "VMware-vCenter-Server-Appliance 7.0.0.10100 generic build 16386292 VMware, Inc. x86_64", + "sysContact": "", + "version": "7.0.0.10100", + "hardware": null, + "features": "build 16386292", + "os": "vmware-vcsa", + "type": "server", + "serial": null, + "icon": "vmware.svg", + "location": "" + } + ] + } + }, + "ports": { + "discovery": { + "ports": [ + { + "port_descr_type": null, + "port_descr_descr": null, + "port_descr_circuit": null, + "port_descr_speed": null, + "port_descr_notes": null, + "ifDescr": "Device eth0 at 03:00.0 VMware - VMXNET3 Ethernet Controller", + "ifName": "Device eth0 at 03:00.0 VMware - VMXNET3 Ethernet Controller", + "portName": null, + "ifIndex": 2, + "ifSpeed": null, + "ifSpeed_prev": null, + "ifConnectorPresent": null, + "ifPromiscuousMode": null, + "ifHighSpeed": null, + "ifHighSpeed_prev": null, + "ifOperStatus": "up", + "ifOperStatus_prev": null, + "ifAdminStatus": null, + "ifAdminStatus_prev": null, + "ifDuplex": null, + "ifMtu": null, + "ifType": "ethernetCsmacd", + "ifAlias": "Device eth0 at 03:00.0 VMware - VMXNET3 Ethernet Controller", + "ifPhysAddress": null, + "ifHardType": null, + "ifLastChange": 0, + "ifVlan": "", + "ifTrunk": null, + "counter_in": null, + "counter_out": null, + "ignore": 0, + "disabled": 0, + "detailed": 0, + "deleted": 0, + "pagpOperationMode": null, + "pagpPortState": null, + "pagpPartnerDeviceId": null, + "pagpPartnerLearnMethod": null, + "pagpPartnerIfIndex": null, + "pagpPartnerGroupIfIndex": null, + "pagpPartnerDeviceName": null, + "pagpEthcOperationMode": null, + "pagpDeviceId": null, + "pagpGroupIfIndex": null, + "ifInUcastPkts": null, + "ifInUcastPkts_prev": null, + "ifInUcastPkts_delta": null, + "ifInUcastPkts_rate": null, + "ifOutUcastPkts": null, + "ifOutUcastPkts_prev": null, + "ifOutUcastPkts_delta": null, + "ifOutUcastPkts_rate": null, + "ifInErrors": null, + "ifInErrors_prev": null, + "ifInErrors_delta": null, + "ifInErrors_rate": null, + "ifOutErrors": null, + "ifOutErrors_prev": null, + "ifOutErrors_delta": null, + "ifOutErrors_rate": null, + "ifInOctets": null, + "ifInOctets_prev": null, + "ifInOctets_delta": null, + "ifInOctets_rate": null, + "ifOutOctets": null, + "ifOutOctets_prev": null, + "ifOutOctets_delta": null, + "ifOutOctets_rate": null, + "poll_prev": null, + "ifInNUcastPkts": null, + "ifInNUcastPkts_prev": null, + "ifInNUcastPkts_delta": null, + "ifInNUcastPkts_rate": null, + "ifOutNUcastPkts": null, + "ifOutNUcastPkts_prev": null, + "ifOutNUcastPkts_delta": null, + "ifOutNUcastPkts_rate": null, + "ifInDiscards": null, + "ifInDiscards_prev": null, + "ifInDiscards_delta": null, + "ifInDiscards_rate": null, + "ifOutDiscards": null, + "ifOutDiscards_prev": null, + "ifOutDiscards_delta": null, + "ifOutDiscards_rate": null, + "ifInUnknownProtos": null, + "ifInUnknownProtos_prev": null, + "ifInUnknownProtos_delta": null, + "ifInUnknownProtos_rate": null, + "ifInBroadcastPkts": null, + "ifInBroadcastPkts_prev": null, + "ifInBroadcastPkts_delta": null, + "ifInBroadcastPkts_rate": null, + "ifOutBroadcastPkts": null, + "ifOutBroadcastPkts_prev": null, + "ifOutBroadcastPkts_delta": null, + "ifOutBroadcastPkts_rate": null, + "ifInMulticastPkts": null, + "ifInMulticastPkts_prev": null, + "ifInMulticastPkts_delta": null, + "ifInMulticastPkts_rate": null, + "ifOutMulticastPkts": null, + "ifOutMulticastPkts_prev": null, + "ifOutMulticastPkts_delta": null, + "ifOutMulticastPkts_rate": null + } + ] + }, + "poller": { + "ports": [ + { + "port_descr_type": null, + "port_descr_descr": null, + "port_descr_circuit": null, + "port_descr_speed": null, + "port_descr_notes": null, + "ifDescr": "eth0", + "ifName": "eth0", + "portName": null, + "ifIndex": 2, + "ifSpeed": 1000000000, + "ifSpeed_prev": null, + "ifConnectorPresent": null, + "ifPromiscuousMode": null, + "ifHighSpeed": null, + "ifHighSpeed_prev": null, + "ifOperStatus": "up", + "ifOperStatus_prev": "up", + "ifAdminStatus": "up", + "ifAdminStatus_prev": null, + "ifDuplex": null, + "ifMtu": 1500, + "ifType": "ethernetCsmacd", + "ifAlias": "eth0", + "ifPhysAddress": "0050568b3265", + "ifHardType": null, + "ifLastChange": 0, + "ifVlan": "", + "ifTrunk": null, + "counter_in": null, + "counter_out": null, + "ignore": 0, + "disabled": 0, + "detailed": 0, + "deleted": 0, + "pagpOperationMode": null, + "pagpPortState": null, + "pagpPartnerDeviceId": null, + "pagpPartnerLearnMethod": null, + "pagpPartnerIfIndex": null, + "pagpPartnerGroupIfIndex": null, + "pagpPartnerDeviceName": null, + "pagpEthcOperationMode": null, + "pagpDeviceId": null, + "pagpGroupIfIndex": null, + "ifInUcastPkts": 78262625, + "ifInUcastPkts_prev": 0, + "ifInUcastPkts_delta": null, + "ifInUcastPkts_rate": null, + "ifOutUcastPkts": 90086228, + "ifOutUcastPkts_prev": 0, + "ifOutUcastPkts_delta": null, + "ifOutUcastPkts_rate": null, + "ifInErrors": 0, + "ifInErrors_prev": 0, + "ifInErrors_delta": null, + "ifInErrors_rate": null, + "ifOutErrors": 0, + "ifOutErrors_prev": 0, + "ifOutErrors_delta": null, + "ifOutErrors_rate": null, + "ifInOctets": 1952111926, + "ifInOctets_prev": 0, + "ifInOctets_delta": null, + "ifInOctets_rate": null, + "ifOutOctets": 3510549083, + "ifOutOctets_prev": 0, + "ifOutOctets_delta": null, + "ifOutOctets_rate": null, + "poll_prev": null, + "ifInNUcastPkts": 130629, + "ifInNUcastPkts_prev": 0, + "ifInNUcastPkts_delta": null, + "ifInNUcastPkts_rate": null, + "ifOutNUcastPkts": 2, + "ifOutNUcastPkts_prev": 0, + "ifOutNUcastPkts_delta": null, + "ifOutNUcastPkts_rate": null, + "ifInDiscards": 0, + "ifInDiscards_prev": 0, + "ifInDiscards_delta": null, + "ifInDiscards_rate": null, + "ifOutDiscards": 0, + "ifOutDiscards_prev": 0, + "ifOutDiscards_delta": null, + "ifOutDiscards_rate": null, + "ifInUnknownProtos": 0, + "ifInUnknownProtos_prev": 0, + "ifInUnknownProtos_delta": null, + "ifInUnknownProtos_rate": null, + "ifInBroadcastPkts": 0, + "ifInBroadcastPkts_prev": 0, + "ifInBroadcastPkts_delta": null, + "ifInBroadcastPkts_rate": null, + "ifOutBroadcastPkts": 0, + "ifOutBroadcastPkts_prev": 0, + "ifOutBroadcastPkts_delta": null, + "ifOutBroadcastPkts_rate": null, + "ifInMulticastPkts": 0, + "ifInMulticastPkts_prev": 0, + "ifInMulticastPkts_delta": null, + "ifInMulticastPkts_rate": null, + "ifOutMulticastPkts": 0, + "ifOutMulticastPkts_prev": 0, + "ifOutMulticastPkts_delta": null, + "ifOutMulticastPkts_rate": null + } + ] + } + }, + "processors": { + "discovery": { + "processors": [ + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 1, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.1", + "processor_index": "1", + "processor_type": "hr", + "processor_usage": 7, + "processor_descr": "Pkg/ID/Node: 0/0/0 Intel Xeon E5-2650 0 @ 2.00GHz", + "processor_precision": 1, + "processor_perc_warn": 75 + }, + { + "entPhysicalIndex": 0, + "hrDeviceIndex": 2, + "processor_oid": ".1.3.6.1.2.1.25.3.3.1.2.2", + "processor_index": "2", + "processor_type": "hr", + "processor_usage": 6, + "processor_descr": "Pkg/ID/Node: 0/1/0 Intel Xeon E5-2650 0 @ 2.00GHz", + "processor_precision": 1, + "processor_perc_warn": 75 + } + ] + }, + "poller": "matches discovery" + }, + "storage": { + "discovery": { + "storage": [ + { + "storage_mib": "hrstorage", + "storage_index": "10", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/imagebuilder", + "storage_size": 10493382656, + "storage_units": 4096, + "storage_used": 37785600, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "11", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/archive", + "storage_size": 52567703552, + "storage_units": 4096, + "storage_used": 47312330752, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "12", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/vtsdb", + "storage_size": 10493382656, + "storage_units": 4096, + "storage_used": 70434816, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "13", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/updatemgr", + "storage_size": 105143787520, + "storage_units": 4096, + "storage_used": 5886812160, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "14", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/netdump", + "storage_size": 1031823360, + "storage_units": 4096, + "storage_used": 2605056, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "15", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/db", + "storage_size": 10493382656, + "storage_units": 4096, + "storage_used": 472928256, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "16", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/autodeploy", + "storage_size": 10493382656, + "storage_units": 4096, + "storage_used": 37781504, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "17", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/seat", + "storage_size": 10493382656, + "storage_units": 4096, + "storage_used": 3988561920, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "18", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/dblog", + "storage_size": 15777865728, + "storage_units": 4096, + "storage_used": 159420416, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "19", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/log", + "storage_size": 10493382656, + "storage_units": 4096, + "storage_used": 5526183936, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "2", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/dev/shm", + "storage_size": 6289756160, + "storage_units": 4096, + "storage_used": 958464, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "20", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/core", + "storage_size": 26279645184, + "storage_units": 4096, + "storage_used": 476229632, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "21", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/var/spool/snmp", + "storage_size": 1048576, + "storage_units": 4096, + "storage_used": 0, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "3", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/run", + "storage_size": 6289756160, + "storage_units": 4096, + "storage_used": 1216512, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "4", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/sys/fs/cgroup", + "storage_size": 6289756160, + "storage_units": 4096, + "storage_used": 0, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "5", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/", + "storage_size": 49270169600, + "storage_units": 4096, + "storage_used": 10129330176, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "6", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/tmp", + "storage_size": 6289756160, + "storage_units": 4096, + "storage_used": 4857856, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "7", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/boot", + "storage_size": 125783040, + "storage_units": 1024, + "storage_used": 28205056, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "8", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/vtsdblog", + "storage_size": 5208932352, + "storage_units": 4096, + "storage_used": 54497280, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "9", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/lifecycle", + "storage_size": 105143787520, + "storage_units": 4096, + "storage_used": 2524815360, + "storage_free": 0, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + } + ] + }, + "poller": { + "storage": [ + { + "storage_mib": "hrstorage", + "storage_index": "10", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/imagebuilder", + "storage_size": 10493382656, + "storage_units": 4096, + "storage_used": 37785600, + "storage_free": 10455597056, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "11", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/archive", + "storage_size": 52567703552, + "storage_units": 4096, + "storage_used": 47312330752, + "storage_free": 5255372800, + "storage_perc": 90, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "12", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/vtsdb", + "storage_size": 10493382656, + "storage_units": 4096, + "storage_used": 70434816, + "storage_free": 10422947840, + "storage_perc": 1, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "13", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/updatemgr", + "storage_size": 105143787520, + "storage_units": 4096, + "storage_used": 5886812160, + "storage_free": 99256975360, + "storage_perc": 6, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "14", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/netdump", + "storage_size": 1031823360, + "storage_units": 4096, + "storage_used": 2605056, + "storage_free": 1029218304, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "15", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/db", + "storage_size": 10493382656, + "storage_units": 4096, + "storage_used": 472928256, + "storage_free": 10020454400, + "storage_perc": 5, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "16", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/autodeploy", + "storage_size": 10493382656, + "storage_units": 4096, + "storage_used": 37781504, + "storage_free": 10455601152, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "17", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/seat", + "storage_size": 10493382656, + "storage_units": 4096, + "storage_used": 3988561920, + "storage_free": 6504820736, + "storage_perc": 38, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "18", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/dblog", + "storage_size": 15777865728, + "storage_units": 4096, + "storage_used": 159420416, + "storage_free": 15618445312, + "storage_perc": 1, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "19", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/log", + "storage_size": 10493382656, + "storage_units": 4096, + "storage_used": 5526183936, + "storage_free": 4967198720, + "storage_perc": 53, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "2", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/dev/shm", + "storage_size": 6289756160, + "storage_units": 4096, + "storage_used": 958464, + "storage_free": 6288797696, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "20", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/core", + "storage_size": 26279645184, + "storage_units": 4096, + "storage_used": 476229632, + "storage_free": 25803415552, + "storage_perc": 2, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "21", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/var/spool/snmp", + "storage_size": 1048576, + "storage_units": 4096, + "storage_used": 0, + "storage_free": 1048576, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "3", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/run", + "storage_size": 6289756160, + "storage_units": 4096, + "storage_used": 1216512, + "storage_free": 6288539648, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "4", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/sys/fs/cgroup", + "storage_size": 6289756160, + "storage_units": 4096, + "storage_used": 0, + "storage_free": 6289756160, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "5", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/", + "storage_size": 49270169600, + "storage_units": 4096, + "storage_used": 10129330176, + "storage_free": 39140839424, + "storage_perc": 21, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "6", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/tmp", + "storage_size": 6289756160, + "storage_units": 4096, + "storage_used": 4857856, + "storage_free": 6284898304, + "storage_perc": 0, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "7", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/boot", + "storage_size": 125783040, + "storage_units": 1024, + "storage_used": 28205056, + "storage_free": 97577984, + "storage_perc": 22, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "8", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/vtsdblog", + "storage_size": 5208932352, + "storage_units": 4096, + "storage_used": 54497280, + "storage_free": 5154435072, + "storage_perc": 1, + "storage_perc_warn": 60, + "storage_deleted": 0 + }, + { + "storage_mib": "hrstorage", + "storage_index": "9", + "storage_type": "hrStorageFixedDisk", + "storage_descr": "/storage/lifecycle", + "storage_size": 105143787520, + "storage_units": 4096, + "storage_used": 2524815360, + "storage_free": 102618972160, + "storage_perc": 2, + "storage_perc_warn": 60, + "storage_deleted": 0 + } + ] + } + } +} diff --git a/tests/snmpsim/vmware-esxi.snmprec b/tests/snmpsim/vmware-esxi.snmprec new file mode 100644 index 0000000000..2447b27057 --- /dev/null +++ b/tests/snmpsim/vmware-esxi.snmprec @@ -0,0 +1,1075 @@ +1.3.6.1.2.1.1.1.0|4|VMware ESXi 7.0.0 build-15843807 VMware, Inc. x86_64 +1.3.6.1.2.1.1.2.0|6|1.3.6.1.4.1.6876.4.1 +1.3.6.1.2.1.1.3.0|67|92095900 +1.3.6.1.2.1.1.4.0|4| +1.3.6.1.2.1.1.5.0|4| +1.3.6.1.2.1.1.6.0|4| +1.3.6.1.2.1.2.2.1.2.1|4|Device vmnic4 at 07:00.0 i40en +1.3.6.1.2.1.2.2.1.2.2|4|Device vmnic5 at 07:00.1 i40en +1.3.6.1.2.1.2.2.1.2.3|4|Device vmnic0 at 03:00.0 ntg3 +1.3.6.1.2.1.2.2.1.2.4|4|Device vmnic1 at 03:00.1 ntg3 +1.3.6.1.2.1.2.2.1.2.5|4|Device vmnic2 at 03:00.2 ntg3 +1.3.6.1.2.1.2.2.1.2.6|4|Device vmnic3 at 03:00.3 ntg3 +1.3.6.1.2.1.2.2.1.2.7|4|Distributed Virtual VMware switch: DvsPortset-0 +1.3.6.1.2.1.2.2.1.2.8|4|Virtual interface: vmk0 on port 67108877 DVS 50 0b ca a7 dc 38 ca 3b-ca 5f 9e c1 bd 75 af 95 +1.3.6.1.2.1.2.2.1.2.9|4|Virtual interface: vmk2 on port 67108879 DVS 50 0b ca a7 dc 38 ca 3b-ca 5f 9e c1 bd 75 af 95 +1.3.6.1.2.1.2.2.1.3.1|2|6 +1.3.6.1.2.1.2.2.1.3.2|2|6 +1.3.6.1.2.1.2.2.1.3.3|2|6 +1.3.6.1.2.1.2.2.1.3.4|2|6 +1.3.6.1.2.1.2.2.1.3.5|2|6 +1.3.6.1.2.1.2.2.1.3.6|2|6 +1.3.6.1.2.1.2.2.1.3.7|2|54 +1.3.6.1.2.1.2.2.1.3.8|2|258 +1.3.6.1.2.1.2.2.1.3.9|2|258 +1.3.6.1.2.1.2.2.1.4.1|2|9000 +1.3.6.1.2.1.2.2.1.4.2|2|9000 +1.3.6.1.2.1.2.2.1.4.3|2|1500 +1.3.6.1.2.1.2.2.1.4.4|2|1500 +1.3.6.1.2.1.2.2.1.4.5|2|1500 +1.3.6.1.2.1.2.2.1.4.6|2|1500 +1.3.6.1.2.1.2.2.1.4.7|2|9000 +1.3.6.1.2.1.2.2.1.4.8|2|9000 +1.3.6.1.2.1.2.2.1.4.9|2|1500 +1.3.6.1.2.1.2.2.1.6.1|4x|3CFDFEBCEA3C +1.3.6.1.2.1.2.2.1.6.2|4x|3CFDFEBCEA3D +1.3.6.1.2.1.2.2.1.6.3|4x|AC162D8C3D68 +1.3.6.1.2.1.2.2.1.6.4|4x|AC162D8C3D69 +1.3.6.1.2.1.2.2.1.6.5|4x|AC162D8C3D6A +1.3.6.1.2.1.2.2.1.6.6|4x|AC162D8C3D6B +1.3.6.1.2.1.2.2.1.6.7|4x|000000000000 +1.3.6.1.2.1.2.2.1.6.8|4x|3CFDFEBCEA3C +1.3.6.1.2.1.2.2.1.6.9|4x|005056630214 +1.3.6.1.2.1.2.2.1.7.1|2|1 +1.3.6.1.2.1.2.2.1.7.2|2|1 +1.3.6.1.2.1.2.2.1.7.3|2|1 +1.3.6.1.2.1.2.2.1.7.4|2|1 +1.3.6.1.2.1.2.2.1.7.5|2|1 +1.3.6.1.2.1.2.2.1.7.6|2|1 +1.3.6.1.2.1.2.2.1.7.7|2|1 +1.3.6.1.2.1.2.2.1.7.8|2|1 +1.3.6.1.2.1.2.2.1.7.9|2|1 +1.3.6.1.2.1.2.2.1.8.1|2|1 +1.3.6.1.2.1.2.2.1.8.2|2|1 +1.3.6.1.2.1.2.2.1.8.3|2|2 +1.3.6.1.2.1.2.2.1.8.4|2|2 +1.3.6.1.2.1.2.2.1.8.5|2|2 +1.3.6.1.2.1.2.2.1.8.6|2|2 +1.3.6.1.2.1.2.2.1.8.7|2|1 +1.3.6.1.2.1.2.2.1.8.8|2|1 +1.3.6.1.2.1.2.2.1.8.9|2|1 +1.3.6.1.2.1.2.2.1.9.1|67|0 +1.3.6.1.2.1.2.2.1.9.2|67|0 +1.3.6.1.2.1.2.2.1.9.3|67|0 +1.3.6.1.2.1.2.2.1.9.4|67|0 +1.3.6.1.2.1.2.2.1.9.5|67|0 +1.3.6.1.2.1.2.2.1.9.6|67|0 +1.3.6.1.2.1.2.2.1.9.7|67|0 +1.3.6.1.2.1.2.2.1.9.8|67|0 +1.3.6.1.2.1.2.2.1.9.9|67|0 +1.3.6.1.2.1.2.2.1.13.1|65|0 +1.3.6.1.2.1.2.2.1.13.2|65|0 +1.3.6.1.2.1.2.2.1.13.3|65|0 +1.3.6.1.2.1.2.2.1.13.4|65|0 +1.3.6.1.2.1.2.2.1.13.5|65|0 +1.3.6.1.2.1.2.2.1.13.6|65|0 +1.3.6.1.2.1.2.2.1.13.7|65|0 +1.3.6.1.2.1.2.2.1.13.8|65|0 +1.3.6.1.2.1.2.2.1.13.9|65|0 +1.3.6.1.2.1.2.2.1.14.1|65|0 +1.3.6.1.2.1.2.2.1.14.2|65|0 +1.3.6.1.2.1.2.2.1.14.3|65|0 +1.3.6.1.2.1.2.2.1.14.4|65|0 +1.3.6.1.2.1.2.2.1.14.5|65|0 +1.3.6.1.2.1.2.2.1.14.6|65|0 +1.3.6.1.2.1.2.2.1.14.7|65|0 +1.3.6.1.2.1.2.2.1.14.8|65|0 +1.3.6.1.2.1.2.2.1.14.9|65|0 +1.3.6.1.2.1.2.2.1.19.1|65|0 +1.3.6.1.2.1.2.2.1.19.2|65|0 +1.3.6.1.2.1.2.2.1.19.3|65|0 +1.3.6.1.2.1.2.2.1.19.4|65|0 +1.3.6.1.2.1.2.2.1.19.5|65|0 +1.3.6.1.2.1.2.2.1.19.6|65|0 +1.3.6.1.2.1.2.2.1.19.7|65|0 +1.3.6.1.2.1.2.2.1.19.8|65|12032 +1.3.6.1.2.1.2.2.1.19.9|65|4295 +1.3.6.1.2.1.2.2.1.20.1|65|0 +1.3.6.1.2.1.2.2.1.20.2|65|0 +1.3.6.1.2.1.2.2.1.20.3|65|0 +1.3.6.1.2.1.2.2.1.20.4|65|0 +1.3.6.1.2.1.2.2.1.20.5|65|0 +1.3.6.1.2.1.2.2.1.20.6|65|0 +1.3.6.1.2.1.2.2.1.20.7|65|0 +1.3.6.1.2.1.2.2.1.20.8|65|0 +1.3.6.1.2.1.2.2.1.20.9|65|0 +1.3.6.1.2.1.4.3.0|65|1450560167 +1.3.6.1.2.1.4.4.0|65|0 +1.3.6.1.2.1.4.5.0|65|0 +1.3.6.1.2.1.4.6.0|65|0 +1.3.6.1.2.1.4.7.0|65|0 +1.3.6.1.2.1.4.8.0|65|0 +1.3.6.1.2.1.4.9.0|65|1451962297 +1.3.6.1.2.1.4.10.0|65|0 +1.3.6.1.2.1.4.11.0|65|0 +1.3.6.1.2.1.4.12.0|65|0 +1.3.6.1.2.1.4.14.0|65|0 +1.3.6.1.2.1.4.15.0|65|0 +1.3.6.1.2.1.4.16.0|65|0 +1.3.6.1.2.1.4.17.0|65|0 +1.3.6.1.2.1.4.18.0|65|0 +1.3.6.1.2.1.4.19.0|65|0 +1.3.6.1.2.1.4.24.3.0|66|0 +1.3.6.1.2.1.4.31.1.1.3.1|65|0 +1.3.6.1.2.1.4.31.1.1.4.1|70|40105265831 +1.3.6.1.2.1.4.31.1.1.5.1|65|0 +1.3.6.1.2.1.4.31.1.1.6.1|70|0 +1.3.6.1.2.1.4.31.1.1.7.1|65|0 +1.3.6.1.2.1.4.31.1.1.8.1|65|0 +1.3.6.1.2.1.4.31.1.1.9.1|65|0 +1.3.6.1.2.1.4.31.1.1.10.1|65|0 +1.3.6.1.2.1.4.31.1.1.11.1|65|0 +1.3.6.1.2.1.4.31.1.1.12.1|65|0 +1.3.6.1.2.1.4.31.1.1.13.1|70|0 +1.3.6.1.2.1.4.31.1.1.14.1|65|0 +1.3.6.1.2.1.4.31.1.1.15.1|65|0 +1.3.6.1.2.1.4.31.1.1.16.1|65|0 +1.3.6.1.2.1.4.31.1.1.17.1|65|0 +1.3.6.1.2.1.4.31.1.1.18.1|65|0 +1.3.6.1.2.1.4.31.1.1.19.1|70|40106667961 +1.3.6.1.2.1.4.31.1.1.20.1|65|0 +1.3.6.1.2.1.4.31.1.1.21.1|70|20412778251 +1.3.6.1.2.1.4.31.1.1.22.1|65|0 +1.3.6.1.2.1.4.31.1.1.23.1|65|0 +1.3.6.1.2.1.4.31.1.1.24.1|70|0 +1.3.6.1.2.1.4.31.1.1.25.1|65|0 +1.3.6.1.2.1.4.31.1.1.26.1|65|0 +1.3.6.1.2.1.4.31.1.1.27.1|65|0 +1.3.6.1.2.1.4.31.1.1.28.1|65|0 +1.3.6.1.2.1.4.31.1.1.29.1|65|0 +1.3.6.1.2.1.4.31.1.1.30.1|65|0 +1.3.6.1.2.1.4.31.1.1.31.1|70|40106667961 +1.3.6.1.2.1.4.31.1.1.32.1|65|0 +1.3.6.1.2.1.4.31.1.1.33.1|70|0 +1.3.6.1.2.1.4.31.1.1.34.1|65|0 +1.3.6.1.2.1.4.31.1.1.35.1|70|0 +1.3.6.1.2.1.4.31.1.1.36.1|65|0 +1.3.6.1.2.1.4.31.1.1.37.1|70|0 +1.3.6.1.2.1.4.31.1.1.38.1|65|0 +1.3.6.1.2.1.4.31.1.1.39.1|70|0 +1.3.6.1.2.1.4.31.1.1.40.1|65|0 +1.3.6.1.2.1.4.31.1.1.41.1|70|0 +1.3.6.1.2.1.4.31.1.1.42.1|65|0 +1.3.6.1.2.1.4.31.1.1.43.1|70|0 +1.3.6.1.2.1.4.31.1.1.44.1|65|0 +1.3.6.1.2.1.4.31.1.1.45.1|70|0 +1.3.6.1.2.1.4.31.1.1.46.1|67|0 +1.3.6.1.2.1.4.31.1.1.47.1|66|5000 +1.3.6.1.2.1.4.35.1.4.8.1.4.10.10.101.1|4x|00405687EF52 +1.3.6.1.2.1.4.35.1.4.8.1.4.10.10.101.30|4x|0040568B9245 +1.3.6.1.2.1.4.35.1.4.8.1.4.10.10.101.32|4x|3CDDEEACA648 +1.3.6.1.2.1.4.35.1.4.8.1.4.10.10.101.33|4x|3CFDFEBCE7E8 +1.3.6.1.2.1.4.35.1.4.8.1.4.10.10.101.99|4x|0CD46A2941B1 +1.3.6.1.2.1.4.35.1.4.8.1.4.10.10.101.100|4x|0015604637C1 +1.3.6.1.2.1.4.35.1.4.8.1.4.10.10.101.101|4x|001532B63FFC +1.3.6.1.2.1.4.35.1.4.9.1.4.10.10.61.10|4x|002336B11F34 +1.3.6.1.2.1.5.29.1.2.1|65|381273 +1.3.6.1.2.1.5.29.1.3.1|65|0 +1.3.6.1.2.1.5.29.1.4.1|65|381297 +1.3.6.1.2.1.5.29.1.5.1|65|24 +1.3.6.1.2.1.6.5.0|65|974569 +1.3.6.1.2.1.6.6.0|65|3340234 +1.3.6.1.2.1.6.7.0|65|106219 +1.3.6.1.2.1.6.8.0|65|1858529 +1.3.6.1.2.1.6.9.0|66|30 +1.3.6.1.2.1.6.10.0|65|1429556203 +1.3.6.1.2.1.6.11.0|65|3225355822 +1.3.6.1.2.1.6.12.0|65|0 +1.3.6.1.2.1.6.14.0|65|0 +1.3.6.1.2.1.6.15.0|65|0 +1.3.6.1.2.1.6.19.1.7.1.4.10.10.61.31.993.1.4.10.10.61.10.2049|2|5 +1.3.6.1.2.1.7.1.0|65|0 +1.3.6.1.2.1.7.2.0|65|24 +1.3.6.1.2.1.7.3.0|65|0 +1.3.6.1.2.1.7.4.0|65|0 +1.3.6.1.2.1.11.1.0|65|298194 +1.3.6.1.2.1.11.2.0|65|298193 +1.3.6.1.2.1.11.3.0|65|0 +1.3.6.1.2.1.11.4.0|65|0 +1.3.6.1.2.1.11.5.0|65|0 +1.3.6.1.2.1.11.6.0|65|0 +1.3.6.1.2.1.11.8.0|65|0 +1.3.6.1.2.1.11.9.0|65|0 +1.3.6.1.2.1.11.10.0|65|0 +1.3.6.1.2.1.11.11.0|65|0 +1.3.6.1.2.1.11.12.0|65|0 +1.3.6.1.2.1.11.13.0|65|298941 +1.3.6.1.2.1.11.14.0|65|0 +1.3.6.1.2.1.11.15.0|65|62597 +1.3.6.1.2.1.11.16.0|65|12231 +1.3.6.1.2.1.11.17.0|65|0 +1.3.6.1.2.1.11.18.0|65|0 +1.3.6.1.2.1.11.19.0|65|0 +1.3.6.1.2.1.11.20.0|65|0 +1.3.6.1.2.1.11.21.0|65|0 +1.3.6.1.2.1.11.22.0|65|0 +1.3.6.1.2.1.11.24.0|65|0 +1.3.6.1.2.1.11.25.0|65|0 +1.3.6.1.2.1.11.26.0|65|0 +1.3.6.1.2.1.11.27.0|65|0 +1.3.6.1.2.1.11.28.0|65|298195 +1.3.6.1.2.1.11.29.0|65|0 +1.3.6.1.2.1.11.31.0|65|0 +1.3.6.1.2.1.25.1.1.0|67|1592066200 +1.3.6.1.2.1.25.1.5.0|66|0 +1.3.6.1.2.1.25.1.6.0|66|95 +1.3.6.1.2.1.25.2.2.0|2|201290968 +1.3.6.1.2.1.25.2.3.1.1.1|2|1 +1.3.6.1.2.1.25.2.3.1.1.2|2|2 +1.3.6.1.2.1.25.2.3.1.1.3|2|3 +1.3.6.1.2.1.25.2.3.1.1.4|2|4 +1.3.6.1.2.1.25.2.3.1.1.5|2|5 +1.3.6.1.2.1.25.2.3.1.1.6|2|6 +1.3.6.1.2.1.25.2.3.1.1.7|2|7 +1.3.6.1.2.1.25.2.3.1.1.8|2|8 +1.3.6.1.2.1.25.2.3.1.1.9|2|9 +1.3.6.1.2.1.25.2.3.1.2.1|6|1.3.6.1.2.1.25.2.1.8 +1.3.6.1.2.1.25.2.3.1.2.2|6|1.3.6.1.2.1.25.2.1.8 +1.3.6.1.2.1.25.2.3.1.2.3|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.4|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.5|6|1.3.6.1.2.1.25.2.1.10 +1.3.6.1.2.1.25.2.3.1.2.6|6|1.3.6.1.2.1.25.2.1.10 +1.3.6.1.2.1.25.2.3.1.2.7|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.8|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.9|6|1.3.6.1.2.1.25.2.1.2 +1.3.6.1.2.1.25.2.3.1.3.1|4|/vmfs/volumes/42e40393-eb4009d5-1981-5d539017033c +1.3.6.1.2.1.25.2.3.1.3.2|4|/vmfs/volumes/5ea85958-f3cc2304-6482-3cfdfebcea3c +1.3.6.1.2.1.25.2.3.1.3.3|4|/vmfs/volumes/5c18205f-7fb22b14-d42f-3cfdfebcea3c +1.3.6.1.2.1.25.2.3.1.3.4|4|/vmfs/volumes/5ea85a96-a262cce2-8120-3cfdfebcea3c +1.3.6.1.2.1.25.2.3.1.3.5|4|/vmfs/volumes/foo-vmw +1.3.6.1.2.1.25.2.3.1.3.6|4|/vmfs/volumes/bar-vm +1.3.6.1.2.1.25.2.3.1.3.7|4|/vmfs/volumes/7c6de8dc-33a02fdb-0000-000000000000 +1.3.6.1.2.1.25.2.3.1.3.8|4|/vmfs/volumes/c08a74ec-a07bfa75-0000-000000000000 +1.3.6.1.2.1.25.2.3.1.3.9|4|Real Memory +1.3.6.1.2.1.25.2.3.1.4.1|2|8192 +1.3.6.1.2.1.25.2.3.1.4.2|2|8192 +1.3.6.1.2.1.25.2.3.1.4.3|2|1048576 +1.3.6.1.2.1.25.2.3.1.4.4|2|1048576 +1.3.6.1.2.1.25.2.3.1.4.5|2|4096 +1.3.6.1.2.1.25.2.3.1.4.6|2|4096 +1.3.6.1.2.1.25.2.3.1.4.7|2|32768 +1.3.6.1.2.1.25.2.3.1.4.8|2|32768 +1.3.6.1.2.1.25.2.3.1.4.9|2|1024 +1.3.6.1.2.1.25.2.3.1.5.1|2|63966 +1.3.6.1.2.1.25.2.3.1.5.2|2|63966 +1.3.6.1.2.1.25.2.3.1.5.3|2|278272 +1.3.6.1.2.1.25.2.3.1.5.4|2|6400 +1.3.6.1.2.1.25.2.3.1.5.5|2|317604521 +1.3.6.1.2.1.25.2.3.1.5.6|2|366085992 +1.3.6.1.2.1.25.2.3.1.5.7|2|1098746656 +1.3.6.1.2.1.25.2.3.1.5.8|2|1098746656 +1.3.6.1.2.1.25.2.3.1.5.9|2|201290968 +1.3.6.1.2.1.25.2.3.1.6.1|2|21712 +1.3.6.1.2.1.25.2.3.1.6.2|2|21713 +1.3.6.1.2.1.25.2.3.1.6.3|2|4448 +1.3.6.1.2.1.25.2.3.1.6.4|2|1775 +1.3.6.1.2.1.25.2.3.1.6.5|2|235062510 +1.3.6.1.2.1.25.2.3.1.6.6|2|220228540 +1.3.6.1.2.1.25.2.3.1.6.7|2|408642833 +1.3.6.1.2.1.25.2.3.1.6.8|2|408642833 +1.3.6.1.2.1.25.2.3.1.6.9|2|98305080 +1.3.6.1.2.1.25.2.3.1.7.1|65|0 +1.3.6.1.2.1.25.2.3.1.7.2|65|0 +1.3.6.1.2.1.25.2.3.1.7.3|65|0 +1.3.6.1.2.1.25.2.3.1.7.4|65|0 +1.3.6.1.2.1.25.2.3.1.7.5|65|0 +1.3.6.1.2.1.25.2.3.1.7.6|65|0 +1.3.6.1.2.1.25.2.3.1.7.7|65|0 +1.3.6.1.2.1.25.2.3.1.7.8|65|0 +1.3.6.1.2.1.25.2.3.1.7.9|65|0 +1.3.6.1.2.1.25.3.2.1.1.1|2|1 +1.3.6.1.2.1.25.3.2.1.1.2|2|2 +1.3.6.1.2.1.25.3.2.1.1.3|2|3 +1.3.6.1.2.1.25.3.2.1.1.4|2|4 +1.3.6.1.2.1.25.3.2.1.1.5|2|5 +1.3.6.1.2.1.25.3.2.1.1.6|2|6 +1.3.6.1.2.1.25.3.2.1.1.7|2|7 +1.3.6.1.2.1.25.3.2.1.1.8|2|8 +1.3.6.1.2.1.25.3.2.1.1.9|2|9 +1.3.6.1.2.1.25.3.2.1.1.10|2|10 +1.3.6.1.2.1.25.3.2.1.1.11|2|11 +1.3.6.1.2.1.25.3.2.1.1.12|2|12 +1.3.6.1.2.1.25.3.2.1.1.13|2|13 +1.3.6.1.2.1.25.3.2.1.1.14|2|14 +1.3.6.1.2.1.25.3.2.1.1.15|2|15 +1.3.6.1.2.1.25.3.2.1.1.16|2|16 +1.3.6.1.2.1.25.3.2.1.1.17|2|17 +1.3.6.1.2.1.25.3.2.1.1.18|2|18 +1.3.6.1.2.1.25.3.2.1.1.19|2|19 +1.3.6.1.2.1.25.3.2.1.1.20|2|20 +1.3.6.1.2.1.25.3.2.1.1.21|2|21 +1.3.6.1.2.1.25.3.2.1.1.22|2|22 +1.3.6.1.2.1.25.3.2.1.1.23|2|23 +1.3.6.1.2.1.25.3.2.1.1.24|2|24 +1.3.6.1.2.1.25.3.2.1.1.25|2|25 +1.3.6.1.2.1.25.3.2.1.1.26|2|26 +1.3.6.1.2.1.25.3.2.1.1.27|2|27 +1.3.6.1.2.1.25.3.2.1.1.28|2|28 +1.3.6.1.2.1.25.3.2.1.1.29|2|29 +1.3.6.1.2.1.25.3.2.1.1.30|2|30 +1.3.6.1.2.1.25.3.2.1.1.31|2|31 +1.3.6.1.2.1.25.3.2.1.1.32|2|32 +1.3.6.1.2.1.25.3.2.1.1.34|2|34 +1.3.6.1.2.1.25.3.2.1.1.35|2|35 +1.3.6.1.2.1.25.3.2.1.1.36|2|36 +1.3.6.1.2.1.25.3.2.1.1.37|2|37 +1.3.6.1.2.1.25.3.2.1.1.38|2|38 +1.3.6.1.2.1.25.3.2.1.1.39|2|39 +1.3.6.1.2.1.25.3.2.1.1.40|2|40 +1.3.6.1.2.1.25.3.2.1.1.41|2|41 +1.3.6.1.2.1.25.3.2.1.1.42|2|42 +1.3.6.1.2.1.25.3.2.1.1.43|2|43 +1.3.6.1.2.1.25.3.2.1.1.44|2|44 +1.3.6.1.2.1.25.3.2.1.1.45|2|45 +1.3.6.1.2.1.25.3.2.1.1.46|2|46 +1.3.6.1.2.1.25.3.2.1.1.47|2|47 +1.3.6.1.2.1.25.3.2.1.1.48|2|48 +1.3.6.1.2.1.25.3.2.1.1.49|2|49 +1.3.6.1.2.1.25.3.2.1.1.50|2|50 +1.3.6.1.2.1.25.3.2.1.1.51|2|51 +1.3.6.1.2.1.25.3.2.1.1.52|2|52 +1.3.6.1.2.1.25.3.2.1.1.53|2|53 +1.3.6.1.2.1.25.3.2.1.1.54|2|54 +1.3.6.1.2.1.25.3.2.1.1.55|2|55 +1.3.6.1.2.1.25.3.2.1.1.56|2|56 +1.3.6.1.2.1.25.3.2.1.1.57|2|57 +1.3.6.1.2.1.25.3.2.1.1.58|2|58 +1.3.6.1.2.1.25.3.2.1.1.59|2|59 +1.3.6.1.2.1.25.3.2.1.2.1|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.2|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.3|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.4|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.5|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.6|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.7|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.8|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.9|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.10|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.11|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.12|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.13|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.14|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.15|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.16|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.17|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.18|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.19|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.20|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.21|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.22|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.23|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.24|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.25|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.26|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.27|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.28|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.29|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.30|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.31|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.32|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.34|6|1.3.6.1.2.1.25.3.1.4 +1.3.6.1.2.1.25.3.2.1.2.35|6|1.3.6.1.2.1.25.3.1.4 +1.3.6.1.2.1.25.3.2.1.2.36|6|1.3.6.1.2.1.25.3.1.4 +1.3.6.1.2.1.25.3.2.1.2.37|6|1.3.6.1.2.1.25.3.1.4 +1.3.6.1.2.1.25.3.2.1.2.38|6|1.3.6.1.2.1.25.3.1.4 +1.3.6.1.2.1.25.3.2.1.2.39|6|1.3.6.1.2.1.25.3.1.4 +1.3.6.1.2.1.25.3.2.1.2.40|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.41|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.42|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.2.43|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.2.44|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.2.45|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.2.46|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.2.47|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.2.48|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.2.49|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.2.50|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.2.51|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.2.52|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.2.53|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.2.54|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.2.55|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.2.56|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.2.57|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.2.58|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.2.59|6|1.3.6.1.2.1.25.3.1.1 +1.3.6.1.2.1.25.3.2.1.3.1|4|CPU Pkg/ID/Node: 0/0/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GHz +1.3.6.1.2.1.25.3.2.1.3.2|4|CPU Pkg/ID/Node: 0/1/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GHz +1.3.6.1.2.1.25.3.2.1.3.3|4|CPU Pkg/ID/Node: 0/2/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GHz +1.3.6.1.2.1.25.3.2.1.3.4|4|CPU Pkg/ID/Node: 0/3/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GHz +1.3.6.1.2.1.25.3.2.1.3.5|4|CPU Pkg/ID/Node: 0/4/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GHz +1.3.6.1.2.1.25.3.2.1.3.6|4|CPU Pkg/ID/Node: 0/5/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GHz +1.3.6.1.2.1.25.3.2.1.3.7|4|CPU Pkg/ID/Node: 0/6/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GHz +1.3.6.1.2.1.25.3.2.1.3.8|4|CPU Pkg/ID/Node: 0/7/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GHz +1.3.6.1.2.1.25.3.2.1.3.9|4|CPU Pkg/ID/Node: 0/8/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GHz +1.3.6.1.2.1.25.3.2.1.3.10|4|CPU Pkg/ID/Node: 0/9/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GHz +1.3.6.1.2.1.25.3.2.1.3.11|4|CPU Pkg/ID/Node: 0/10/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.12|4|CPU Pkg/ID/Node: 0/11/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.13|4|CPU Pkg/ID/Node: 0/12/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.14|4|CPU Pkg/ID/Node: 0/13/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.15|4|CPU Pkg/ID/Node: 0/14/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.16|4|CPU Pkg/ID/Node: 0/15/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.17|4|CPU Pkg/ID/Node: 1/16/1 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.18|4|CPU Pkg/ID/Node: 1/17/1 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.19|4|CPU Pkg/ID/Node: 1/18/1 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.20|4|CPU Pkg/ID/Node: 1/19/1 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.21|4|CPU Pkg/ID/Node: 1/20/1 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.22|4|CPU Pkg/ID/Node: 1/21/1 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.23|4|CPU Pkg/ID/Node: 1/22/1 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.24|4|CPU Pkg/ID/Node: 1/23/1 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.25|4|CPU Pkg/ID/Node: 1/24/1 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.26|4|CPU Pkg/ID/Node: 1/25/1 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.27|4|CPU Pkg/ID/Node: 1/26/1 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.28|4|CPU Pkg/ID/Node: 1/27/1 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.29|4|CPU Pkg/ID/Node: 1/28/1 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.30|4|CPU Pkg/ID/Node: 1/29/1 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.31|4|CPU Pkg/ID/Node: 1/30/1 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.32|4|CPU Pkg/ID/Node: 1/31/1 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GH +1.3.6.1.2.1.25.3.2.1.3.34|4|NIC vmnic4, driver i40en, version 1.8.1.16, 0000:007:00.0 +1.3.6.1.2.1.25.3.2.1.3.35|4|NIC vmnic5, driver i40en, version 1.8.1.16, 0000:007:00.1 +1.3.6.1.2.1.25.3.2.1.3.36|4|NIC vmnic0, driver ntg3, version 4.1.4.1, 0000:003:00.0 +1.3.6.1.2.1.25.3.2.1.3.37|4|NIC vmnic1, driver ntg3, version 4.1.4.1, 0000:003:00.1 +1.3.6.1.2.1.25.3.2.1.3.38|4|NIC vmnic2, driver ntg3, version 4.1.4.1, 0000:003:00.2 +1.3.6.1.2.1.25.3.2.1.3.39|4|NIC vmnic3, driver ntg3, version 4.1.4.1, 0000:003:00.3 +1.3.6.1.2.1.25.3.2.1.3.40|4|LUN hp DVDRAM GT50N E700 mpx.vmhba64:C0:T0:L0 +1.3.6.1.2.1.25.3.2.1.3.41|4|LUN HP LOGICAL VOLUME 8.32 naa.601505c1101va377eed3b35bad585d11 +1.3.6.1.2.1.25.3.2.1.3.42|4|POWER 34-PCI 1 Zone +1.3.6.1.2.1.25.3.2.1.3.43|4|POWER Power Supply 1 +1.3.6.1.2.1.25.3.2.1.3.44|4|POWER 35-PCI 2 Zone +1.3.6.1.2.1.25.3.2.1.3.45|4|POWER Power Supply 2 +1.3.6.1.2.1.25.3.2.1.3.46|4|POWER 36-PCI 3 Zone +1.3.6.1.2.1.25.3.2.1.3.47|4|POWER 37-PCI 4 Zone +1.3.6.1.2.1.25.3.2.1.3.48|4|POWER 38-PCI 5 Zone +1.3.6.1.2.1.25.3.2.1.3.49|4|POWER 39-PCI 6 Zone +1.3.6.1.2.1.25.3.2.1.3.50|4|POWER 40-I/O Board 1 +1.3.6.1.2.1.25.3.2.1.3.51|4|POWER 41-I/O Board 2 +1.3.6.1.2.1.25.3.2.1.3.52|4|FAN Fan 1 +1.3.6.1.2.1.25.3.2.1.3.53|4|FAN Fan 2 +1.3.6.1.2.1.25.3.2.1.3.54|4|FAN Fan 3 +1.3.6.1.2.1.25.3.2.1.3.55|4|FAN Fan 4 +1.3.6.1.2.1.25.3.2.1.3.56|4|FAN Fan 5 +1.3.6.1.2.1.25.3.2.1.3.57|4|FAN Fan 6 +1.3.6.1.2.1.25.3.2.1.3.58|4|MEMORY Memory +1.3.6.1.2.1.25.3.2.1.3.59|4|UNKNOWN Power Meter +1.3.6.1.2.1.25.3.2.1.5.1|2|1 +1.3.6.1.2.1.25.3.2.1.5.2|2|1 +1.3.6.1.2.1.25.3.2.1.5.3|2|1 +1.3.6.1.2.1.25.3.2.1.5.4|2|1 +1.3.6.1.2.1.25.3.2.1.5.5|2|1 +1.3.6.1.2.1.25.3.2.1.5.6|2|1 +1.3.6.1.2.1.25.3.2.1.5.7|2|1 +1.3.6.1.2.1.25.3.2.1.5.8|2|1 +1.3.6.1.2.1.25.3.2.1.5.9|2|1 +1.3.6.1.2.1.25.3.2.1.5.10|2|1 +1.3.6.1.2.1.25.3.2.1.5.11|2|1 +1.3.6.1.2.1.25.3.2.1.5.12|2|1 +1.3.6.1.2.1.25.3.2.1.5.13|2|1 +1.3.6.1.2.1.25.3.2.1.5.14|2|1 +1.3.6.1.2.1.25.3.2.1.5.15|2|1 +1.3.6.1.2.1.25.3.2.1.5.16|2|1 +1.3.6.1.2.1.25.3.2.1.5.17|2|1 +1.3.6.1.2.1.25.3.2.1.5.18|2|1 +1.3.6.1.2.1.25.3.2.1.5.19|2|1 +1.3.6.1.2.1.25.3.2.1.5.20|2|1 +1.3.6.1.2.1.25.3.2.1.5.21|2|1 +1.3.6.1.2.1.25.3.2.1.5.22|2|1 +1.3.6.1.2.1.25.3.2.1.5.23|2|1 +1.3.6.1.2.1.25.3.2.1.5.24|2|1 +1.3.6.1.2.1.25.3.2.1.5.25|2|1 +1.3.6.1.2.1.25.3.2.1.5.26|2|1 +1.3.6.1.2.1.25.3.2.1.5.27|2|1 +1.3.6.1.2.1.25.3.2.1.5.28|2|1 +1.3.6.1.2.1.25.3.2.1.5.29|2|1 +1.3.6.1.2.1.25.3.2.1.5.30|2|1 +1.3.6.1.2.1.25.3.2.1.5.31|2|1 +1.3.6.1.2.1.25.3.2.1.5.32|2|1 +1.3.6.1.2.1.25.3.2.1.5.34|2|1 +1.3.6.1.2.1.25.3.2.1.5.35|2|1 +1.3.6.1.2.1.25.3.2.1.5.36|2|1 +1.3.6.1.2.1.25.3.2.1.5.37|2|1 +1.3.6.1.2.1.25.3.2.1.5.38|2|1 +1.3.6.1.2.1.25.3.2.1.5.39|2|1 +1.3.6.1.2.1.25.3.2.1.5.40|2|1 +1.3.6.1.2.1.25.3.2.1.5.41|2|1 +1.3.6.1.2.1.25.3.2.1.5.42|2|2 +1.3.6.1.2.1.25.3.2.1.5.43|2|2 +1.3.6.1.2.1.25.3.2.1.5.44|2|2 +1.3.6.1.2.1.25.3.2.1.5.45|2|2 +1.3.6.1.2.1.25.3.2.1.5.46|2|2 +1.3.6.1.2.1.25.3.2.1.5.47|2|2 +1.3.6.1.2.1.25.3.2.1.5.48|2|2 +1.3.6.1.2.1.25.3.2.1.5.49|2|2 +1.3.6.1.2.1.25.3.2.1.5.50|2|2 +1.3.6.1.2.1.25.3.2.1.5.51|2|2 +1.3.6.1.2.1.25.3.2.1.5.52|2|2 +1.3.6.1.2.1.25.3.2.1.5.53|2|2 +1.3.6.1.2.1.25.3.2.1.5.54|2|2 +1.3.6.1.2.1.25.3.2.1.5.55|2|2 +1.3.6.1.2.1.25.3.2.1.5.56|2|2 +1.3.6.1.2.1.25.3.2.1.5.57|2|2 +1.3.6.1.2.1.25.3.2.1.5.58|2|2 +1.3.6.1.2.1.25.3.2.1.5.59|2|3 +1.3.6.1.2.1.25.3.2.1.6.1|65|0 +1.3.6.1.2.1.25.3.2.1.6.2|65|0 +1.3.6.1.2.1.25.3.2.1.6.3|65|0 +1.3.6.1.2.1.25.3.2.1.6.4|65|0 +1.3.6.1.2.1.25.3.2.1.6.5|65|0 +1.3.6.1.2.1.25.3.2.1.6.6|65|0 +1.3.6.1.2.1.25.3.2.1.6.7|65|0 +1.3.6.1.2.1.25.3.2.1.6.8|65|0 +1.3.6.1.2.1.25.3.2.1.6.9|65|0 +1.3.6.1.2.1.25.3.2.1.6.10|65|0 +1.3.6.1.2.1.25.3.2.1.6.11|65|0 +1.3.6.1.2.1.25.3.2.1.6.12|65|0 +1.3.6.1.2.1.25.3.2.1.6.13|65|0 +1.3.6.1.2.1.25.3.2.1.6.14|65|0 +1.3.6.1.2.1.25.3.2.1.6.15|65|0 +1.3.6.1.2.1.25.3.2.1.6.16|65|0 +1.3.6.1.2.1.25.3.2.1.6.17|65|0 +1.3.6.1.2.1.25.3.2.1.6.18|65|0 +1.3.6.1.2.1.25.3.2.1.6.19|65|0 +1.3.6.1.2.1.25.3.2.1.6.20|65|0 +1.3.6.1.2.1.25.3.2.1.6.21|65|0 +1.3.6.1.2.1.25.3.2.1.6.22|65|0 +1.3.6.1.2.1.25.3.2.1.6.23|65|0 +1.3.6.1.2.1.25.3.2.1.6.24|65|0 +1.3.6.1.2.1.25.3.2.1.6.25|65|0 +1.3.6.1.2.1.25.3.2.1.6.26|65|0 +1.3.6.1.2.1.25.3.2.1.6.27|65|0 +1.3.6.1.2.1.25.3.2.1.6.28|65|0 +1.3.6.1.2.1.25.3.2.1.6.29|65|0 +1.3.6.1.2.1.25.3.2.1.6.30|65|0 +1.3.6.1.2.1.25.3.2.1.6.31|65|0 +1.3.6.1.2.1.25.3.2.1.6.32|65|0 +1.3.6.1.2.1.25.3.2.1.6.34|65|0 +1.3.6.1.2.1.25.3.2.1.6.35|65|0 +1.3.6.1.2.1.25.3.2.1.6.36|65|0 +1.3.6.1.2.1.25.3.2.1.6.37|65|0 +1.3.6.1.2.1.25.3.2.1.6.38|65|0 +1.3.6.1.2.1.25.3.2.1.6.39|65|0 +1.3.6.1.2.1.25.3.2.1.6.40|65|0 +1.3.6.1.2.1.25.3.2.1.6.41|65|0 +1.3.6.1.2.1.25.3.2.1.6.42|65|0 +1.3.6.1.2.1.25.3.2.1.6.43|65|0 +1.3.6.1.2.1.25.3.2.1.6.44|65|0 +1.3.6.1.2.1.25.3.2.1.6.45|65|0 +1.3.6.1.2.1.25.3.2.1.6.46|65|0 +1.3.6.1.2.1.25.3.2.1.6.47|65|0 +1.3.6.1.2.1.25.3.2.1.6.48|65|0 +1.3.6.1.2.1.25.3.2.1.6.49|65|0 +1.3.6.1.2.1.25.3.2.1.6.50|65|0 +1.3.6.1.2.1.25.3.2.1.6.51|65|0 +1.3.6.1.2.1.25.3.2.1.6.52|65|0 +1.3.6.1.2.1.25.3.2.1.6.53|65|0 +1.3.6.1.2.1.25.3.2.1.6.54|65|0 +1.3.6.1.2.1.25.3.2.1.6.55|65|0 +1.3.6.1.2.1.25.3.2.1.6.56|65|0 +1.3.6.1.2.1.25.3.2.1.6.57|65|0 +1.3.6.1.2.1.25.3.2.1.6.58|65|0 +1.3.6.1.2.1.25.3.2.1.6.59|65|0 +1.3.6.1.2.1.25.3.3.1.2.1|2|23 +1.3.6.1.2.1.25.3.3.1.2.2|2|23 +1.3.6.1.2.1.25.3.3.1.2.3|2|23 +1.3.6.1.2.1.25.3.3.1.2.4|2|19 +1.3.6.1.2.1.25.3.3.1.2.5|2|20 +1.3.6.1.2.1.25.3.3.1.2.6|2|21 +1.3.6.1.2.1.25.3.3.1.2.7|2|28 +1.3.6.1.2.1.25.3.3.1.2.8|2|16 +1.3.6.1.2.1.25.3.3.1.2.9|2|24 +1.3.6.1.2.1.25.3.3.1.2.10|2|17 +1.3.6.1.2.1.25.3.3.1.2.11|2|3 +1.3.6.1.2.1.25.3.3.1.2.12|2|24 +1.3.6.1.2.1.25.3.3.1.2.13|2|17 +1.3.6.1.2.1.25.3.3.1.2.14|2|10 +1.3.6.1.2.1.25.3.3.1.2.15|2|11 +1.3.6.1.2.1.25.3.3.1.2.16|2|23 +1.3.6.1.2.1.25.3.3.1.2.17|2|10 +1.3.6.1.2.1.25.3.3.1.2.18|2|7 +1.3.6.1.2.1.25.3.3.1.2.19|2|10 +1.3.6.1.2.1.25.3.3.1.2.20|2|13 +1.3.6.1.2.1.25.3.3.1.2.21|2|3 +1.3.6.1.2.1.25.3.3.1.2.22|2|3 +1.3.6.1.2.1.25.3.3.1.2.23|2|9 +1.3.6.1.2.1.25.3.3.1.2.24|2|8 +1.3.6.1.2.1.25.3.3.1.2.25|2|6 +1.3.6.1.2.1.25.3.3.1.2.26|2|3 +1.3.6.1.2.1.25.3.3.1.2.27|2|8 +1.3.6.1.2.1.25.3.3.1.2.28|2|3 +1.3.6.1.2.1.25.3.3.1.2.29|2|3 +1.3.6.1.2.1.25.3.3.1.2.30|2|10 +1.3.6.1.2.1.25.3.3.1.2.31|2|8 +1.3.6.1.2.1.25.3.3.1.2.32|2|9 +1.3.6.1.2.1.31.1.1.1.1.1|4|vmnic4 +1.3.6.1.2.1.31.1.1.1.1.2|4|vmnic5 +1.3.6.1.2.1.31.1.1.1.1.3|4|vmnic0 +1.3.6.1.2.1.31.1.1.1.1.4|4|vmnic1 +1.3.6.1.2.1.31.1.1.1.1.5|4|vmnic2 +1.3.6.1.2.1.31.1.1.1.1.6|4|vmnic3 +1.3.6.1.2.1.31.1.1.1.1.7|4|DvsPortset-0 +1.3.6.1.2.1.31.1.1.1.1.8|4|vmk0 +1.3.6.1.2.1.31.1.1.1.1.9|4|vmk2 +1.3.6.1.2.1.31.1.1.1.2.1|65|0 +1.3.6.1.2.1.31.1.1.1.2.2|65|0 +1.3.6.1.2.1.31.1.1.1.2.3|65|0 +1.3.6.1.2.1.31.1.1.1.2.4|65|0 +1.3.6.1.2.1.31.1.1.1.2.5|65|0 +1.3.6.1.2.1.31.1.1.1.2.6|65|0 +1.3.6.1.2.1.31.1.1.1.2.7|65|1351134 +1.3.6.1.2.1.31.1.1.1.2.8|65|0 +1.3.6.1.2.1.31.1.1.1.2.9|65|0 +1.3.6.1.2.1.31.1.1.1.3.1|65|0 +1.3.6.1.2.1.31.1.1.1.3.2|65|0 +1.3.6.1.2.1.31.1.1.1.3.3|65|0 +1.3.6.1.2.1.31.1.1.1.3.4|65|0 +1.3.6.1.2.1.31.1.1.1.3.5|65|0 +1.3.6.1.2.1.31.1.1.1.3.6|65|0 +1.3.6.1.2.1.31.1.1.1.3.7|65|962323 +1.3.6.1.2.1.31.1.1.1.3.8|65|166411 +1.3.6.1.2.1.31.1.1.1.3.9|65|33702 +1.3.6.1.2.1.31.1.1.1.4.1|65|0 +1.3.6.1.2.1.31.1.1.1.4.2|65|0 +1.3.6.1.2.1.31.1.1.1.4.3|65|0 +1.3.6.1.2.1.31.1.1.1.4.4|65|0 +1.3.6.1.2.1.31.1.1.1.4.5|65|0 +1.3.6.1.2.1.31.1.1.1.4.6|65|0 +1.3.6.1.2.1.31.1.1.1.4.7|65|44520014 +1.3.6.1.2.1.31.1.1.1.4.8|65|2 +1.3.6.1.2.1.31.1.1.1.4.9|65|2 +1.3.6.1.2.1.31.1.1.1.5.1|65|0 +1.3.6.1.2.1.31.1.1.1.5.2|65|0 +1.3.6.1.2.1.31.1.1.1.5.3|65|0 +1.3.6.1.2.1.31.1.1.1.5.4|65|0 +1.3.6.1.2.1.31.1.1.1.5.5|65|0 +1.3.6.1.2.1.31.1.1.1.5.6|65|0 +1.3.6.1.2.1.31.1.1.1.5.7|65|3840297997 +1.3.6.1.2.1.31.1.1.1.5.8|65|40000 +1.3.6.1.2.1.31.1.1.1.5.9|65|16938 +1.3.6.1.2.1.31.1.1.1.6.1|70|233481089086071 +1.3.6.1.2.1.31.1.1.1.6.2|70|100828535445858 +1.3.6.1.2.1.31.1.1.1.6.3|70|0 +1.3.6.1.2.1.31.1.1.1.6.4|70|0 +1.3.6.1.2.1.31.1.1.1.6.5|70|0 +1.3.6.1.2.1.31.1.1.1.6.6|70|0 +1.3.6.1.2.1.31.1.1.1.6.7|70|0 +1.3.6.1.2.1.31.1.1.1.6.8|70|35533170324878 +1.3.6.1.2.1.31.1.1.1.6.9|70|1944922838830 +1.3.6.1.2.1.31.1.1.1.7.1|70|0 +1.3.6.1.2.1.31.1.1.1.7.2|70|0 +1.3.6.1.2.1.31.1.1.1.7.3|70|0 +1.3.6.1.2.1.31.1.1.1.7.4|70|0 +1.3.6.1.2.1.31.1.1.1.7.5|70|0 +1.3.6.1.2.1.31.1.1.1.7.6|70|0 +1.3.6.1.2.1.31.1.1.1.7.7|70|597765549347 +1.3.6.1.2.1.31.1.1.1.7.8|70|38459581559 +1.3.6.1.2.1.31.1.1.1.7.9|70|1216249839 +1.3.6.1.2.1.31.1.1.1.8.1|70|0 +1.3.6.1.2.1.31.1.1.1.8.2|70|0 +1.3.6.1.2.1.31.1.1.1.8.3|70|0 +1.3.6.1.2.1.31.1.1.1.8.4|70|0 +1.3.6.1.2.1.31.1.1.1.8.5|70|0 +1.3.6.1.2.1.31.1.1.1.8.6|70|0 +1.3.6.1.2.1.31.1.1.1.8.7|70|1351134 +1.3.6.1.2.1.31.1.1.1.8.8|70|0 +1.3.6.1.2.1.31.1.1.1.8.9|70|0 +1.3.6.1.2.1.31.1.1.1.9.1|70|0 +1.3.6.1.2.1.31.1.1.1.9.2|70|0 +1.3.6.1.2.1.31.1.1.1.9.3|70|0 +1.3.6.1.2.1.31.1.1.1.9.4|70|0 +1.3.6.1.2.1.31.1.1.1.9.5|70|0 +1.3.6.1.2.1.31.1.1.1.9.6|70|0 +1.3.6.1.2.1.31.1.1.1.9.7|70|962323 +1.3.6.1.2.1.31.1.1.1.9.8|70|166411 +1.3.6.1.2.1.31.1.1.1.9.9|70|33702 +1.3.6.1.2.1.31.1.1.1.10.1|70|114246316241540 +1.3.6.1.2.1.31.1.1.1.10.2|70|68674682590179 +1.3.6.1.2.1.31.1.1.1.10.3|70|0 +1.3.6.1.2.1.31.1.1.1.10.4|70|0 +1.3.6.1.2.1.31.1.1.1.10.5|70|0 +1.3.6.1.2.1.31.1.1.1.10.6|70|0 +1.3.6.1.2.1.31.1.1.1.10.7|70|0 +1.3.6.1.2.1.31.1.1.1.10.8|70|50830957055706 +1.3.6.1.2.1.31.1.1.1.10.9|70|6578753553836 +1.3.6.1.2.1.31.1.1.1.11.1|70|0 +1.3.6.1.2.1.31.1.1.1.11.2|70|0 +1.3.6.1.2.1.31.1.1.1.11.3|70|0 +1.3.6.1.2.1.31.1.1.1.11.4|70|0 +1.3.6.1.2.1.31.1.1.1.11.5|70|0 +1.3.6.1.2.1.31.1.1.1.11.6|70|0 +1.3.6.1.2.1.31.1.1.1.11.7|70|981732208398 +1.3.6.1.2.1.31.1.1.1.11.8|70|19142670714 +1.3.6.1.2.1.31.1.1.1.11.9|70|840661918 +1.3.6.1.2.1.31.1.1.1.12.1|70|0 +1.3.6.1.2.1.31.1.1.1.12.2|70|0 +1.3.6.1.2.1.31.1.1.1.12.3|70|0 +1.3.6.1.2.1.31.1.1.1.12.4|70|0 +1.3.6.1.2.1.31.1.1.1.12.5|70|0 +1.3.6.1.2.1.31.1.1.1.12.6|70|0 +1.3.6.1.2.1.31.1.1.1.12.7|70|44520014 +1.3.6.1.2.1.31.1.1.1.12.8|70|2 +1.3.6.1.2.1.31.1.1.1.12.9|70|2 +1.3.6.1.2.1.31.1.1.1.13.1|70|0 +1.3.6.1.2.1.31.1.1.1.13.2|70|0 +1.3.6.1.2.1.31.1.1.1.13.3|70|0 +1.3.6.1.2.1.31.1.1.1.13.4|70|0 +1.3.6.1.2.1.31.1.1.1.13.5|70|0 +1.3.6.1.2.1.31.1.1.1.13.6|70|0 +1.3.6.1.2.1.31.1.1.1.13.7|70|3840297997 +1.3.6.1.2.1.31.1.1.1.13.8|70|40000 +1.3.6.1.2.1.31.1.1.1.13.9|70|16938 +1.3.6.1.2.1.31.1.1.1.14.1|2|2 +1.3.6.1.2.1.31.1.1.1.14.2|2|2 +1.3.6.1.2.1.31.1.1.1.14.3|2|2 +1.3.6.1.2.1.31.1.1.1.14.4|2|2 +1.3.6.1.2.1.31.1.1.1.14.5|2|2 +1.3.6.1.2.1.31.1.1.1.14.6|2|2 +1.3.6.1.2.1.31.1.1.1.14.7|2|2 +1.3.6.1.2.1.31.1.1.1.14.8|2|2 +1.3.6.1.2.1.31.1.1.1.14.9|2|2 +1.3.6.1.2.1.31.1.1.1.15.1|66|10000 +1.3.6.1.2.1.31.1.1.1.15.2|66|10000 +1.3.6.1.2.1.31.1.1.1.15.3|66|0 +1.3.6.1.2.1.31.1.1.1.15.4|66|0 +1.3.6.1.2.1.31.1.1.1.15.5|66|0 +1.3.6.1.2.1.31.1.1.1.15.6|66|0 +1.3.6.1.2.1.31.1.1.1.15.7|66|0 +1.3.6.1.2.1.31.1.1.1.15.8|66|0 +1.3.6.1.2.1.31.1.1.1.15.9|66|0 +1.3.6.1.2.1.31.1.1.1.16.1|2|1 +1.3.6.1.2.1.31.1.1.1.16.2|2|1 +1.3.6.1.2.1.31.1.1.1.16.3|2|1 +1.3.6.1.2.1.31.1.1.1.16.4|2|1 +1.3.6.1.2.1.31.1.1.1.16.5|2|1 +1.3.6.1.2.1.31.1.1.1.16.6|2|1 +1.3.6.1.2.1.31.1.1.1.16.7|2|2 +1.3.6.1.2.1.31.1.1.1.16.8|2|2 +1.3.6.1.2.1.31.1.1.1.16.9|2|2 +1.3.6.1.2.1.31.1.1.1.17.1|2|1 +1.3.6.1.2.1.31.1.1.1.17.2|2|1 +1.3.6.1.2.1.31.1.1.1.17.3|2|1 +1.3.6.1.2.1.31.1.1.1.17.4|2|1 +1.3.6.1.2.1.31.1.1.1.17.5|2|1 +1.3.6.1.2.1.31.1.1.1.17.6|2|1 +1.3.6.1.2.1.31.1.1.1.17.7|2|2 +1.3.6.1.2.1.31.1.1.1.17.8|2|2 +1.3.6.1.2.1.31.1.1.1.17.9|2|2 +1.3.6.1.2.1.31.1.1.1.18.1|4|07:00.0 +1.3.6.1.2.1.31.1.1.1.18.2|4|07:00.1 +1.3.6.1.2.1.31.1.1.1.18.3|4|03:00.0 +1.3.6.1.2.1.31.1.1.1.18.4|4|03:00.1 +1.3.6.1.2.1.31.1.1.1.18.5|4|03:00.2 +1.3.6.1.2.1.31.1.1.1.18.6|4|03:00.3 +1.3.6.1.2.1.31.1.1.1.18.7|4|DvsPortset-0 +1.3.6.1.2.1.31.1.1.1.18.8|4|vmk0- +1.3.6.1.2.1.31.1.1.1.18.9|4|vmk2- +1.3.6.1.2.1.31.1.1.1.19.1|67|0 +1.3.6.1.2.1.31.1.1.1.19.2|67|0 +1.3.6.1.2.1.31.1.1.1.19.3|67|0 +1.3.6.1.2.1.31.1.1.1.19.4|67|0 +1.3.6.1.2.1.31.1.1.1.19.5|67|0 +1.3.6.1.2.1.31.1.1.1.19.6|67|0 +1.3.6.1.2.1.31.1.1.1.19.7|67|0 +1.3.6.1.2.1.31.1.1.1.19.8|67|0 +1.3.6.1.2.1.31.1.1.1.19.9|67|0 +1.3.6.1.2.1.31.1.2.1.3.0.3|2|1 +1.3.6.1.2.1.31.1.2.1.3.0.4|2|1 +1.3.6.1.2.1.31.1.2.1.3.0.5|2|1 +1.3.6.1.2.1.31.1.2.1.3.0.6|2|1 +1.3.6.1.2.1.31.1.2.1.3.0.7|2|1 +1.3.6.1.2.1.31.1.2.1.3.0.8|2|1 +1.3.6.1.2.1.31.1.2.1.3.0.9|2|1 +1.3.6.1.2.1.31.1.2.1.3.1.0|2|1 +1.3.6.1.2.1.31.1.2.1.3.2.0|2|1 +1.3.6.1.2.1.31.1.2.1.3.3.0|2|1 +1.3.6.1.2.1.31.1.2.1.3.4.0|2|1 +1.3.6.1.2.1.31.1.2.1.3.5.0|2|1 +1.3.6.1.2.1.31.1.2.1.3.6.0|2|1 +1.3.6.1.2.1.31.1.2.1.3.7.1|2|1 +1.3.6.1.2.1.31.1.2.1.3.7.2|2|1 +1.3.6.1.2.1.31.1.2.1.3.8.0|2|1 +1.3.6.1.2.1.31.1.2.1.3.9.0|2|1 +1.3.6.1.2.1.47.1.1.1.1.2.1|4|HP ProLiant DL380p Gen8 +1.3.6.1.2.1.47.1.1.1.1.3.1|6|0.0 +1.3.6.1.2.1.47.1.1.1.1.4.1|2|0 +1.3.6.1.2.1.47.1.1.1.1.5.1|2|4 +1.3.6.1.2.1.47.1.1.1.1.6.1|2|-1 +1.3.6.1.2.1.47.1.1.1.1.7.1|4|smbios +1.3.6.1.2.1.47.1.1.1.1.8.1|4| +1.3.6.1.2.1.47.1.1.1.1.9.1|4|2.8 +1.3.6.1.2.1.47.1.1.1.1.10.1|4| +1.3.6.1.2.1.47.1.1.1.1.11.1|4|CZ162913BZ +1.3.6.1.2.1.47.1.1.1.1.12.1|4|HP +1.3.6.1.2.1.47.1.1.1.1.13.1|4|ProLiant DL380p Gen8 +1.3.6.1.2.1.47.1.1.1.1.14.1|4| +1.3.6.1.2.1.47.1.1.1.1.15.1|4| +1.3.6.1.2.1.47.1.1.1.1.16.1|2|1 +1.3.6.1.2.1.47.1.1.1.1.17.1|4x|07E2051500000000000000 +1.3.6.1.2.1.47.1.1.1.1.18.1|4|urn:uuid:5d123eb1-4314-442c-4158-1cd17ebc9a2c +1.3.6.1.4.1.6876.1.1.0|4|VMware ESXi +1.3.6.1.4.1.6876.1.2.0|4|7.0.0 +1.3.6.1.4.1.6876.1.4.0|4|15843807 +1.3.6.1.4.1.6876.2.1.1.2.708|4| +1.3.6.1.4.1.6876.2.1.1.2.775|4| +1.3.6.1.4.1.6876.2.1.1.2.1644|4| +1.3.6.1.4.1.6876.2.1.1.2.7092|4| +1.3.6.1.4.1.6876.2.1.1.2.7095|4| +1.3.6.1.4.1.6876.2.1.1.2.7310|4| +1.3.6.1.4.1.6876.2.1.1.2.7642|4| +1.3.6.1.4.1.6876.2.1.1.2.7879|4| +1.3.6.1.4.1.6876.2.1.1.2.7880|4| +1.3.6.1.4.1.6876.2.1.1.2.7913|4| +1.3.6.1.4.1.6876.2.1.1.2.8190|4| +1.3.6.1.4.1.6876.2.1.1.2.8348|4| +1.3.6.1.4.1.6876.2.1.1.2.8371|4| +1.3.6.1.4.1.6876.2.1.1.2.8386|4| +1.3.6.1.4.1.6876.2.1.1.2.8431|4| +1.3.6.1.4.1.6876.2.1.1.2.8432|4| +1.3.6.1.4.1.6876.2.1.1.2.8453|4| +1.3.6.1.4.1.6876.2.1.1.2.8464|4| +1.3.6.1.4.1.6876.2.1.1.2.8465|4| +1.3.6.1.4.1.6876.2.1.1.2.8484|4| +1.3.6.1.4.1.6876.2.1.1.2.8487|4| +1.3.6.1.4.1.6876.2.1.1.2.8491|4| +1.3.6.1.4.1.6876.2.1.1.2.8498|4| +1.3.6.1.4.1.6876.2.1.1.2.8499|4| +1.3.6.1.4.1.6876.2.1.1.2.8502|4| +1.3.6.1.4.1.6876.2.1.1.2.8504|4| +1.3.6.1.4.1.6876.2.1.1.2.8506|4| +1.3.6.1.4.1.6876.2.1.1.2.8507|4| +1.3.6.1.4.1.6876.2.1.1.2.8508|4| +1.3.6.1.4.1.6876.2.1.1.2.8510|4| +1.3.6.1.4.1.6876.2.1.1.2.8511|4| +1.3.6.1.4.1.6876.2.1.1.2.8512|4| +1.3.6.1.4.1.6876.2.1.1.3.708|4|/vmfs/volumes/7c6de8dc-33a02fdb-0000-000000000000//.vmx +1.3.6.1.4.1.6876.2.1.1.3.775|4|/vmfs/volumes/7c6de8dc-33a02fdb-0000-000000000000//.vmx +1.3.6.1.4.1.6876.2.1.1.3.1644|4|/vmfs/volumes/7c6de8dc-33a02fdb-0000-000000000000//.vmx +1.3.6.1.4.1.6876.2.1.1.3.7092|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.7095|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.7310|4|/vmfs/volumes/a9061f5f-da3a78fe//.vmx +1.3.6.1.4.1.6876.2.1.1.3.7642|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.7879|4|/vmfs/volumes/a9061f5f-da3a78fe//.vmx +1.3.6.1.4.1.6876.2.1.1.3.7880|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.7913|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8190|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8348|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8371|4|/vmfs/volumes/a9061f5f-da3a78fe//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8386|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8431|4|/vmfs/volumes/a9061f5f-da3a78fe//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8432|4|/vmfs/volumes/a9061f5f-da3a78fe//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8453|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8464|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8465|4|/vmfs/volumes/a9061f5f-da3a78fe//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8484|4|/vmfs/volumes/a9061f5f-da3a78fe//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8487|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8491|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8498|4|/vmfs/volumes/a9061f5f-da3a78fe//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8499|4|/vmfs/volumes/a9061f5f-da3a78fe//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8502|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8504|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8506|4|/vmfs/volumes/a9061f5f-da3a78fe//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8507|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8508|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8510|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8511|4|/vmfs/volumes/3636a45c-310c81f6//.vmx +1.3.6.1.4.1.6876.2.1.1.3.8512|4|/vmfs/volumes/a9061f5f-da3a78fe//.vmx +1.3.6.1.4.1.6876.2.1.1.4.708|4|E: tools not running +1.3.6.1.4.1.6876.2.1.1.4.775|4|E: tools not running +1.3.6.1.4.1.6876.2.1.1.4.1644|4|E: tools not running +1.3.6.1.4.1.6876.2.1.1.4.7092|4|Linux 4.19.0-10-amd64 Debian GNU/Linux 10 (buster) +1.3.6.1.4.1.6876.2.1.1.4.7095|4|Linux 4.19.0-10-amd64 Debian GNU/Linux 10 (buster) +1.3.6.1.4.1.6876.2.1.1.4.7310|4|Linux 4.9.0-11-amd64 Debian GNU/Linux 9.13 (stretch) +1.3.6.1.4.1.6876.2.1.1.4.7642|4|Linux 4.19.0-10-amd64 Debian GNU/Linux 10 (buster) +1.3.6.1.4.1.6876.2.1.1.4.7879|4|E: tools not installed +1.3.6.1.4.1.6876.2.1.1.4.7880|4|Linux 4.15.0-112-generic Ubuntu 18.04.5 LTS +1.3.6.1.4.1.6876.2.1.1.4.7913|4|Linux 3.16.0-10-amd64 Debian GNU/Linux 8.11 (jessie) +1.3.6.1.4.1.6876.2.1.1.4.8190|4|Linux 4.9.0-13-amd64 Debian GNU/Linux 9.13 (stretch) +1.3.6.1.4.1.6876.2.1.1.4.8348|4|Linux 4.15.0-70-generic Ubuntu 18.04.3 LTS +1.3.6.1.4.1.6876.2.1.1.4.8371|4|Linux 3.16.0-11-amd64 Debian GNU/Linux 8.11 (jessie) +1.3.6.1.4.1.6876.2.1.1.4.8386|4|Linux 4.15.0-101-generic Ubuntu 18.04.4 LTS +1.3.6.1.4.1.6876.2.1.1.4.8431|4|Linux 4.4.0-121-generic Ubuntu 16.04.4 LTS +1.3.6.1.4.1.6876.2.1.1.4.8432|4|Linux 4.19.0-9-amd64 Debian GNU/Linux 10 (buster) +1.3.6.1.4.1.6876.2.1.1.4.8453|4|Linux 4.19.0-6-amd64 Debian GNU/Linux 10 (buster) +1.3.6.1.4.1.6876.2.1.1.4.8464|4|Linux 3.16.0-10-amd64 Debian GNU/Linux 8.11 (jessie) +1.3.6.1.4.1.6876.2.1.1.4.8465|4|Linux 4.19.0-12-amd64 Debian GNU/Linux 10 (buster) +1.3.6.1.4.1.6876.2.1.1.4.8484|4|E: tools not installed +1.3.6.1.4.1.6876.2.1.1.4.8487|4|Linux 4.9.0-13-amd64 Debian GNU/Linux 9.13 (stretch) +1.3.6.1.4.1.6876.2.1.1.4.8491|4|Linux 4.19.0-9-amd64 Debian GNU/Linux 10 (buster) +1.3.6.1.4.1.6876.2.1.1.4.8498|4|FreeBSD 12.1-RELEASE-p7-HBSD +1.3.6.1.4.1.6876.2.1.1.4.8499|4|Linux 4.19.0-8-amd64 Debian GNU/Linux 10 (buster) +1.3.6.1.4.1.6876.2.1.1.4.8502|4|FreeBSD 11.3-RELEASE-p5 +1.3.6.1.4.1.6876.2.1.1.4.8504|4|Linux 3.16.0-4-amd64 Debian GNU/Linux 8.11 (jessie) +1.3.6.1.4.1.6876.2.1.1.4.8506|4|Linux 2.6.32-74-server Ubuntu 10.04.4 LTS +1.3.6.1.4.1.6876.2.1.1.4.8507|4|FreeBSD 12.1-RELEASE-p2 +1.3.6.1.4.1.6876.2.1.1.4.8508|4|Windows Server 2019, 64-bit (Build 17763) +1.3.6.1.4.1.6876.2.1.1.4.8510|4|Linux 5.4.0-52-generic Ubuntu 20.04.1 LTS +1.3.6.1.4.1.6876.2.1.1.4.8511|4|Linux 4.19.4-amd64-vyos Debian GNU/Linux 8.11 (jessie) +1.3.6.1.4.1.6876.2.1.1.4.8512|4|Linux 4.4.0-193-generic Ubuntu 16.04.7 LTS +1.3.6.1.4.1.6876.2.1.1.5.708|2|2048 +1.3.6.1.4.1.6876.2.1.1.5.775|2|2048 +1.3.6.1.4.1.6876.2.1.1.5.1644|2|6144 +1.3.6.1.4.1.6876.2.1.1.5.7092|2|4096 +1.3.6.1.4.1.6876.2.1.1.5.7095|2|4096 +1.3.6.1.4.1.6876.2.1.1.5.7310|2|4096 +1.3.6.1.4.1.6876.2.1.1.5.7642|2|16384 +1.3.6.1.4.1.6876.2.1.1.5.7879|2|2048 +1.3.6.1.4.1.6876.2.1.1.5.7880|2|4096 +1.3.6.1.4.1.6876.2.1.1.5.7913|2|4096 +1.3.6.1.4.1.6876.2.1.1.5.8190|2|4096 +1.3.6.1.4.1.6876.2.1.1.5.8348|2|4096 +1.3.6.1.4.1.6876.2.1.1.5.8371|2|4096 +1.3.6.1.4.1.6876.2.1.1.5.8386|2|4096 +1.3.6.1.4.1.6876.2.1.1.5.8431|2|2048 +1.3.6.1.4.1.6876.2.1.1.5.8432|2|2048 +1.3.6.1.4.1.6876.2.1.1.5.8453|2|4096 +1.3.6.1.4.1.6876.2.1.1.5.8464|2|4096 +1.3.6.1.4.1.6876.2.1.1.5.8465|2|4096 +1.3.6.1.4.1.6876.2.1.1.5.8484|2|3072 +1.3.6.1.4.1.6876.2.1.1.5.8487|2|4096 +1.3.6.1.4.1.6876.2.1.1.5.8491|2|2048 +1.3.6.1.4.1.6876.2.1.1.5.8498|2|2048 +1.3.6.1.4.1.6876.2.1.1.5.8499|2|1024 +1.3.6.1.4.1.6876.2.1.1.5.8502|2|2048 +1.3.6.1.4.1.6876.2.1.1.5.8504|2|4096 +1.3.6.1.4.1.6876.2.1.1.5.8506|2|2048 +1.3.6.1.4.1.6876.2.1.1.5.8507|2|4096 +1.3.6.1.4.1.6876.2.1.1.5.8508|2|8192 +1.3.6.1.4.1.6876.2.1.1.5.8510|2|4096 +1.3.6.1.4.1.6876.2.1.1.5.8511|2|2048 +1.3.6.1.4.1.6876.2.1.1.5.8512|2|1024 +1.3.6.1.4.1.6876.2.1.1.6.708|4|powered off +1.3.6.1.4.1.6876.2.1.1.6.775|4|powered off +1.3.6.1.4.1.6876.2.1.1.6.1644|4|powered off +1.3.6.1.4.1.6876.2.1.1.6.7092|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.7095|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.7310|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.7642|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.7879|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.7880|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.7913|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8190|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8348|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8371|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8386|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8431|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8432|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8453|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8464|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8465|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8484|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8487|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8491|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8498|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8499|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8502|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8504|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8506|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8507|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8508|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8510|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8511|4|powered on +1.3.6.1.4.1.6876.2.1.1.6.8512|4|powered on +1.3.6.1.4.1.6876.2.1.1.8.708|4|not running +1.3.6.1.4.1.6876.2.1.1.8.775|4|not running +1.3.6.1.4.1.6876.2.1.1.8.1644|4|not running +1.3.6.1.4.1.6876.2.1.1.8.7092|4|running +1.3.6.1.4.1.6876.2.1.1.8.7095|4|running +1.3.6.1.4.1.6876.2.1.1.8.7310|4|running +1.3.6.1.4.1.6876.2.1.1.8.7642|4|running +1.3.6.1.4.1.6876.2.1.1.8.7879|4|not running +1.3.6.1.4.1.6876.2.1.1.8.7880|4|running +1.3.6.1.4.1.6876.2.1.1.8.7913|4|running +1.3.6.1.4.1.6876.2.1.1.8.8190|4|running +1.3.6.1.4.1.6876.2.1.1.8.8348|4|running +1.3.6.1.4.1.6876.2.1.1.8.8371|4|running +1.3.6.1.4.1.6876.2.1.1.8.8386|4|running +1.3.6.1.4.1.6876.2.1.1.8.8431|4|running +1.3.6.1.4.1.6876.2.1.1.8.8432|4|running +1.3.6.1.4.1.6876.2.1.1.8.8453|4|running +1.3.6.1.4.1.6876.2.1.1.8.8464|4|running +1.3.6.1.4.1.6876.2.1.1.8.8465|4|running +1.3.6.1.4.1.6876.2.1.1.8.8484|4|not running +1.3.6.1.4.1.6876.2.1.1.8.8487|4|running +1.3.6.1.4.1.6876.2.1.1.8.8491|4|running +1.3.6.1.4.1.6876.2.1.1.8.8498|4|running +1.3.6.1.4.1.6876.2.1.1.8.8499|4|running +1.3.6.1.4.1.6876.2.1.1.8.8502|4|running +1.3.6.1.4.1.6876.2.1.1.8.8504|4|running +1.3.6.1.4.1.6876.2.1.1.8.8506|4|running +1.3.6.1.4.1.6876.2.1.1.8.8507|4|running +1.3.6.1.4.1.6876.2.1.1.8.8508|4|running +1.3.6.1.4.1.6876.2.1.1.8.8510|4|running +1.3.6.1.4.1.6876.2.1.1.8.8511|4|running +1.3.6.1.4.1.6876.2.1.1.8.8512|4|running +1.3.6.1.4.1.6876.2.1.1.9.708|2|2 +1.3.6.1.4.1.6876.2.1.1.9.775|2|2 +1.3.6.1.4.1.6876.2.1.1.9.1644|2|4 +1.3.6.1.4.1.6876.2.1.1.9.7092|2|2 +1.3.6.1.4.1.6876.2.1.1.9.7095|2|2 +1.3.6.1.4.1.6876.2.1.1.9.7310|2|2 +1.3.6.1.4.1.6876.2.1.1.9.7642|2|4 +1.3.6.1.4.1.6876.2.1.1.9.7879|2|1 +1.3.6.1.4.1.6876.2.1.1.9.7880|2|2 +1.3.6.1.4.1.6876.2.1.1.9.7913|2|2 +1.3.6.1.4.1.6876.2.1.1.9.8190|2|2 +1.3.6.1.4.1.6876.2.1.1.9.8348|2|4 +1.3.6.1.4.1.6876.2.1.1.9.8371|2|2 +1.3.6.1.4.1.6876.2.1.1.9.8386|2|4 +1.3.6.1.4.1.6876.2.1.1.9.8431|2|1 +1.3.6.1.4.1.6876.2.1.1.9.8432|2|1 +1.3.6.1.4.1.6876.2.1.1.9.8453|2|4 +1.3.6.1.4.1.6876.2.1.1.9.8464|2|2 +1.3.6.1.4.1.6876.2.1.1.9.8465|2|1 +1.3.6.1.4.1.6876.2.1.1.9.8484|2|4 +1.3.6.1.4.1.6876.2.1.1.9.8487|2|2 +1.3.6.1.4.1.6876.2.1.1.9.8491|2|2 +1.3.6.1.4.1.6876.2.1.1.9.8498|2|2 +1.3.6.1.4.1.6876.2.1.1.9.8499|2|1 +1.3.6.1.4.1.6876.2.1.1.9.8502|2|4 +1.3.6.1.4.1.6876.2.1.1.9.8504|2|2 +1.3.6.1.4.1.6876.2.1.1.9.8506|2|2 +1.3.6.1.4.1.6876.2.1.1.9.8507|2|4 +1.3.6.1.4.1.6876.2.1.1.9.8508|2|4 +1.3.6.1.4.1.6876.2.1.1.9.8510|2|4 +1.3.6.1.4.1.6876.2.1.1.9.8511|2|4 +1.3.6.1.4.1.6876.2.1.1.9.8512|2|1 +1.3.6.1.4.1.6876.2.1.1.10.708|4|420753f9-d904-e5e6-da53-d75590bde424 +1.3.6.1.4.1.6876.2.1.1.10.775|4|420b58fe-7da6-1fee-070d-cb0d10daabd0 +1.3.6.1.4.1.6876.2.1.1.10.1644|4|564d1c83-170e-f375-e2ae-817e0d9aebd1 +1.3.6.1.4.1.6876.2.1.1.10.7092|4|420b8b04-70bb-c0c8-0493-2707cfbf399e +1.3.6.1.4.1.6876.2.1.1.10.7095|4|420ba538-a04e-63a1-b7e5-8319380ff533 +1.3.6.1.4.1.6876.2.1.1.10.7310|4|420773c6-0e16-dada-f3da-6b75dca8cf09 +1.3.6.1.4.1.6876.2.1.1.10.7642|4|420b2d2a-93af-c29f-34b2-0dacbc1d501c +1.3.6.1.4.1.6876.2.1.1.10.7879|4|564db63f-c5b0-ae87-c681-e1050fe9aed8 +1.3.6.1.4.1.6876.2.1.1.10.7880|4|420bb2f9-1dfe-554b-5310-0a027deb4399 +1.3.6.1.4.1.6876.2.1.1.10.7913|4|42074f1a-cffe-a5ac-18e5-5e339abc3c0c +1.3.6.1.4.1.6876.2.1.1.10.8190|4|420b77c6-84d4-1b68-ac7a-31548f2b7c3e +1.3.6.1.4.1.6876.2.1.1.10.8348|4|4236eed9-22d7-db97-019f-fb253000551e +1.3.6.1.4.1.6876.2.1.1.10.8371|4|420714fc-b31b-f80a-3c77-897f86ad90c8 +1.3.6.1.4.1.6876.2.1.1.10.8386|4|423611c8-f782-322e-c659-ac98fe898666 +1.3.6.1.4.1.6876.2.1.1.10.8431|4|421318ef-aae8-49dc-65d4-64a8aaf92125 +1.3.6.1.4.1.6876.2.1.1.10.8432|4|420bf58b-34fa-7b62-9958-0091f10635ec +1.3.6.1.4.1.6876.2.1.1.10.8453|4|420b445b-627a-2e6a-3eea-f7e5debbf0a2 +1.3.6.1.4.1.6876.2.1.1.10.8464|4|42070cd9-82e6-7ee4-82b1-fb444aed63fb +1.3.6.1.4.1.6876.2.1.1.10.8465|4|420be5e9-462f-be96-4537-f3e568d4f194 +1.3.6.1.4.1.6876.2.1.1.10.8484|4|42131e44-1ebe-6bbf-c3f0-81fb955b5956 +1.3.6.1.4.1.6876.2.1.1.10.8487|4|42077512-d20b-cc31-f5ba-1af18d9ff17a +1.3.6.1.4.1.6876.2.1.1.10.8491|4|4207a533-f175-3542-e68c-26b6ed904e58 +1.3.6.1.4.1.6876.2.1.1.10.8498|4|564dc7df-d63d-8f80-60a0-2ab064d9bd4a +1.3.6.1.4.1.6876.2.1.1.10.8499|4|420b5d5c-66c4-eb59-633c-a2b1114dcd0c +1.3.6.1.4.1.6876.2.1.1.10.8502|4|42360f9f-9242-8b22-22c9-15eb5c64a86f +1.3.6.1.4.1.6876.2.1.1.10.8504|4|4213822a-09fc-8e0e-b6d5-75db298ea643 +1.3.6.1.4.1.6876.2.1.1.10.8506|4|4213a619-7f9a-0d6e-15c5-c6eeb0ae0807 +1.3.6.1.4.1.6876.2.1.1.10.8507|4|4236dbdc-adcd-fee7-c59a-9e776a437a23 +1.3.6.1.4.1.6876.2.1.1.10.8508|4|420b2c21-8206-dd8d-9459-1183dd2e40fc +1.3.6.1.4.1.6876.2.1.1.10.8510|4|42366246-f082-975f-c917-53e9fc76b012 +1.3.6.1.4.1.6876.2.1.1.10.8511|4|42078a45-f187-c9de-33af-7fb3c9892251 +1.3.6.1.4.1.6876.2.1.1.10.8512|4|564dbbed-1b08-a7f5-aca8-508f7d791d93 diff --git a/tests/snmpsim/vmware-vcsa.snmprec b/tests/snmpsim/vmware-vcsa.snmprec new file mode 100644 index 0000000000..6328501c2f --- /dev/null +++ b/tests/snmpsim/vmware-vcsa.snmprec @@ -0,0 +1,540 @@ +1.3.6.1.2.1.1.1.0|4|VMware-vCenter-Server-Appliance 7.0.0.10100 generic build 16386292 VMware, Inc. x86_64 +1.3.6.1.2.1.1.2.0|6|1.3.6.1.4.1.6876.4.6 +1.3.6.1.2.1.1.3.0|67|910960857 +1.3.6.1.2.1.1.4.0|4| +1.3.6.1.2.1.1.5.0|4| +1.3.6.1.2.1.1.6.0|4| +1.3.6.1.2.1.2.2.1.1.2|2|2 +1.3.6.1.2.1.2.2.1.2.2|4|Device eth0 at 03:00.0 VMware - VMXNET3 Ethernet Controller +1.3.6.1.2.1.2.2.1.3.2|2|6 +1.3.6.1.2.1.2.2.1.4.2|2|1500 +1.3.6.1.2.1.2.2.1.5.2|66|1000000000 +1.3.6.1.2.1.2.2.1.6.2|4x|0050568B3265 +1.3.6.1.2.1.2.2.1.7.2|2|1 +1.3.6.1.2.1.2.2.1.8.2|2|1 +1.3.6.1.2.1.2.2.1.9.2|67|0 +1.3.6.1.2.1.2.2.1.10.2|65|1952111926 +1.3.6.1.2.1.2.2.1.11.2|65|78262625 +1.3.6.1.2.1.2.2.1.12.2|65|130629 +1.3.6.1.2.1.2.2.1.13.2|65|0 +1.3.6.1.2.1.2.2.1.14.2|65|0 +1.3.6.1.2.1.2.2.1.15.2|65|0 +1.3.6.1.2.1.2.2.1.16.2|65|3510549083 +1.3.6.1.2.1.2.2.1.17.2|65|90086228 +1.3.6.1.2.1.2.2.1.18.2|65|2 +1.3.6.1.2.1.2.2.1.19.2|65|0 +1.3.6.1.2.1.2.2.1.20.2|65|0 +1.3.6.1.2.1.2.2.1.21.2|66|1000 +1.3.6.1.2.1.2.2.1.22.2|6|0.0.0 +1.3.6.1.2.1.4.3.0|65|4174487421 +1.3.6.1.2.1.4.4.0|65|0 +1.3.6.1.2.1.4.5.0|65|0 +1.3.6.1.2.1.4.6.0|65|0 +1.3.6.1.2.1.4.7.0|65|0 +1.3.6.1.2.1.4.8.0|65|0 +1.3.6.1.2.1.4.9.0|65|4174474306 +1.3.6.1.2.1.4.10.0|65|4186275181 +1.3.6.1.2.1.4.11.0|65|40 +1.3.6.1.2.1.4.12.0|65|0 +1.3.6.1.2.1.4.14.0|65|0 +1.3.6.1.2.1.4.15.0|65|0 +1.3.6.1.2.1.4.16.0|65|0 +1.3.6.1.2.1.4.17.0|65|0 +1.3.6.1.2.1.4.18.0|65|0 +1.3.6.1.2.1.4.19.0|65|0 +1.3.6.1.2.1.4.31.1.1.3.1|65|0 +1.3.6.1.2.1.4.31.1.1.3.2|65|0 +1.3.6.1.2.1.4.31.1.1.4.1|70|17929286950768665256 +1.3.6.1.2.1.4.31.1.1.4.2|70|10281640 +1.3.6.1.2.1.4.31.1.1.5.1|65|0 +1.3.6.1.2.1.4.31.1.1.5.2|65|0 +1.3.6.1.2.1.4.31.1.1.6.1|70|10281640 +1.3.6.1.2.1.4.31.1.1.6.2|70|10281640 +1.3.6.1.2.1.4.31.1.1.7.1|65|0 +1.3.6.1.2.1.4.31.1.1.7.2|65|0 +1.3.6.1.2.1.4.31.1.1.8.1|65|0 +1.3.6.1.2.1.4.31.1.1.8.2|65|0 +1.3.6.1.2.1.4.31.1.1.9.1|65|0 +1.3.6.1.2.1.4.31.1.1.9.2|65|0 +1.3.6.1.2.1.4.31.1.1.10.1|65|0 +1.3.6.1.2.1.4.31.1.1.10.2|65|0 +1.3.6.1.2.1.4.31.1.1.11.1|65|0 +1.3.6.1.2.1.4.31.1.1.11.2|65|0 +1.3.6.1.2.1.4.31.1.1.12.1|65|0 +1.3.6.1.2.1.4.31.1.1.12.2|65|0 +1.3.6.1.2.1.4.31.1.1.13.1|70|10281640 +1.3.6.1.2.1.4.31.1.1.13.2|70|10281640 +1.3.6.1.2.1.4.31.1.1.14.1|65|0 +1.3.6.1.2.1.4.31.1.1.14.2|65|0 +1.3.6.1.2.1.4.31.1.1.15.1|65|0 +1.3.6.1.2.1.4.31.1.1.15.2|65|0 +1.3.6.1.2.1.4.31.1.1.16.1|65|0 +1.3.6.1.2.1.4.31.1.1.16.2|65|0 +1.3.6.1.2.1.4.31.1.1.17.1|65|0 +1.3.6.1.2.1.4.31.1.1.17.2|65|0 +1.3.6.1.2.1.4.31.1.1.18.1|65|0 +1.3.6.1.2.1.4.31.1.1.18.2|65|0 +1.3.6.1.2.1.4.31.1.1.19.1|70|17929230622272578216 +1.3.6.1.2.1.4.31.1.1.19.2|70|10281640 +1.3.6.1.2.1.4.31.1.1.20.1|65|0 +1.3.6.1.2.1.4.31.1.1.20.2|65|0 +1.3.6.1.2.1.4.31.1.1.21.1|70|17979914994461762216 +1.3.6.1.2.1.4.31.1.1.21.2|70|25780085416 +1.3.6.1.2.1.4.31.1.1.22.1|65|0 +1.3.6.1.2.1.4.31.1.1.22.2|65|11 +1.3.6.1.2.1.4.31.1.1.23.1|65|0 +1.3.6.1.2.1.4.31.1.1.23.2|65|0 +1.3.6.1.2.1.4.31.1.1.24.1|70|10281640 +1.3.6.1.2.1.4.31.1.1.24.2|70|10281640 +1.3.6.1.2.1.4.31.1.1.25.1|65|40 +1.3.6.1.2.1.4.31.1.1.25.2|65|0 +1.3.6.1.2.1.4.31.1.1.26.1|65|0 +1.3.6.1.2.1.4.31.1.1.26.2|65|0 +1.3.6.1.2.1.4.31.1.1.27.1|65|0 +1.3.6.1.2.1.4.31.1.1.27.2|65|0 +1.3.6.1.2.1.4.31.1.1.28.1|65|0 +1.3.6.1.2.1.4.31.1.1.28.2|65|0 +1.3.6.1.2.1.4.31.1.1.29.1|65|0 +1.3.6.1.2.1.4.31.1.1.29.2|65|0 +1.3.6.1.2.1.4.31.1.1.30.1|65|0 +1.3.6.1.2.1.4.31.1.1.30.2|65|0 +1.3.6.1.2.1.4.31.1.1.31.1|70|10281640 +1.3.6.1.2.1.4.31.1.1.31.2|70|10281640 +1.3.6.1.2.1.4.31.1.1.32.1|65|0 +1.3.6.1.2.1.4.31.1.1.32.2|65|0 +1.3.6.1.2.1.4.31.1.1.33.1|70|10281640 +1.3.6.1.2.1.4.31.1.1.33.2|70|10281640 +1.3.6.1.2.1.4.31.1.1.34.1|65|0 +1.3.6.1.2.1.4.31.1.1.34.2|65|0 +1.3.6.1.2.1.4.31.1.1.35.1|70|10281640 +1.3.6.1.2.1.4.31.1.1.35.2|70|10281640 +1.3.6.1.2.1.4.31.1.1.36.1|65|0 +1.3.6.1.2.1.4.31.1.1.36.2|65|0 +1.3.6.1.2.1.4.31.1.1.37.1|70|10281640 +1.3.6.1.2.1.4.31.1.1.37.2|70|10281640 +1.3.6.1.2.1.4.31.1.1.38.1|65|0 +1.3.6.1.2.1.4.31.1.1.38.2|65|0 +1.3.6.1.2.1.4.31.1.1.39.1|70|10281640 +1.3.6.1.2.1.4.31.1.1.39.2|70|25780085416 +1.3.6.1.2.1.4.31.1.1.40.1|65|0 +1.3.6.1.2.1.4.31.1.1.40.2|65|0 +1.3.6.1.2.1.4.31.1.1.41.1|70|10281640 +1.3.6.1.2.1.4.31.1.1.41.2|70|10281640 +1.3.6.1.2.1.4.31.1.1.42.1|65|0 +1.3.6.1.2.1.4.31.1.1.42.2|65|0 +1.3.6.1.2.1.4.31.1.1.43.1|70|10281640 +1.3.6.1.2.1.4.31.1.1.43.2|70|10281640 +1.3.6.1.2.1.4.31.1.1.44.1|65|0 +1.3.6.1.2.1.4.31.1.1.44.2|65|0 +1.3.6.1.2.1.4.31.1.1.45.1|70|10281640 +1.3.6.1.2.1.4.31.1.1.45.2|70|10281640 +1.3.6.1.2.1.4.31.1.1.46.1|67|0 +1.3.6.1.2.1.4.31.1.1.46.2|67|0 +1.3.6.1.2.1.4.31.1.1.47.1|66|5000 +1.3.6.1.2.1.4.31.1.1.47.2|66|5000 +1.3.6.1.2.1.4.35.1.4.2.1.4.10.10.101.1|4x|00505687EF82 +1.3.6.1.2.1.4.35.1.4.2.1.4.10.10.101.31|4x|3CFDFEBCEA3C +1.3.6.1.2.1.4.35.1.4.2.1.4.10.10.101.32|4x|3CFDFEBCE678 +1.3.6.1.2.1.4.35.1.4.2.1.4.10.10.101.33|4x|3CFDFEBCE7E8 +1.3.6.1.2.1.4.35.1.4.2.1.4.10.10.101.98|4x|0050568B8776 +1.3.6.1.2.1.4.35.1.4.2.1.4.10.10.101.101|4x|005056B65FDB +1.3.6.1.2.1.4.35.1.4.2.1.4.10.10.101.103|4x|00505687A041 +1.3.6.1.2.1.4.35.1.4.2.1.4.10.10.101.104|4x|005056873104 +1.3.6.1.2.1.5.29.1.2.1|65|93928 +1.3.6.1.2.1.5.29.1.2.2|65|0 +1.3.6.1.2.1.5.29.1.3.1|65|3 +1.3.6.1.2.1.5.29.1.3.2|65|0 +1.3.6.1.2.1.5.29.1.4.1|65|0 +1.3.6.1.2.1.5.29.1.4.2|65|6 +1.3.6.1.2.1.5.29.1.5.1|65|93692 +1.3.6.1.2.1.5.29.1.5.2|65|0 +1.3.6.1.2.1.5.30.1.3.1.0|65|92153 +1.3.6.1.2.1.5.30.1.3.1.3|65|0 +1.3.6.1.2.1.5.30.1.3.1.4|65|0 +1.3.6.1.2.1.5.30.1.3.1.5|65|0 +1.3.6.1.2.1.5.30.1.3.1.8|65|0 +1.3.6.1.2.1.5.30.1.3.1.11|65|1775 +1.3.6.1.2.1.5.30.1.3.1.12|65|0 +1.3.6.1.2.1.5.30.1.3.1.13|65|0 +1.3.6.1.2.1.5.30.1.3.1.14|65|0 +1.3.6.1.2.1.5.30.1.3.1.17|65|0 +1.3.6.1.2.1.5.30.1.3.1.18|65|0 +1.3.6.1.2.1.5.30.1.3.2.1|65|0 +1.3.6.1.2.1.5.30.1.3.2.2|65|0 +1.3.6.1.2.1.5.30.1.3.2.3|65|0 +1.3.6.1.2.1.5.30.1.3.2.4|65|0 +1.3.6.1.2.1.5.30.1.3.2.128|65|0 +1.3.6.1.2.1.5.30.1.3.2.129|65|0 +1.3.6.1.2.1.5.30.1.3.2.130|65|0 +1.3.6.1.2.1.5.30.1.3.2.131|65|0 +1.3.6.1.2.1.5.30.1.3.2.132|65|0 +1.3.6.1.2.1.5.30.1.3.2.133|65|0 +1.3.6.1.2.1.5.30.1.3.2.134|65|0 +1.3.6.1.2.1.5.30.1.3.2.135|65|0 +1.3.6.1.2.1.5.30.1.3.2.136|65|0 +1.3.6.1.2.1.5.30.1.3.2.137|65|0 +1.3.6.1.2.1.5.30.1.3.2.143|65|0 +1.3.6.1.2.1.5.30.1.4.1.0|65|0 +1.3.6.1.2.1.5.30.1.4.1.3|65|0 +1.3.6.1.2.1.5.30.1.4.1.4|65|0 +1.3.6.1.2.1.5.30.1.4.1.5|65|0 +1.3.6.1.2.1.5.30.1.4.1.8|65|0 +1.3.6.1.2.1.5.30.1.4.1.11|65|1539 +1.3.6.1.2.1.5.30.1.4.1.12|65|0 +1.3.6.1.2.1.5.30.1.4.1.13|65|92153 +1.3.6.1.2.1.5.30.1.4.1.14|65|0 +1.3.6.1.2.1.5.30.1.4.1.17|65|0 +1.3.6.1.2.1.5.30.1.4.1.18|65|0 +1.3.6.1.2.1.5.30.1.4.2.1|65|0 +1.3.6.1.2.1.5.30.1.4.2.2|65|0 +1.3.6.1.2.1.5.30.1.4.2.3|65|0 +1.3.6.1.2.1.5.30.1.4.2.4|65|0 +1.3.6.1.2.1.5.30.1.4.2.128|65|0 +1.3.6.1.2.1.5.30.1.4.2.129|65|0 +1.3.6.1.2.1.5.30.1.4.2.130|65|0 +1.3.6.1.2.1.5.30.1.4.2.131|65|0 +1.3.6.1.2.1.5.30.1.4.2.132|65|0 +1.3.6.1.2.1.5.30.1.4.2.133|65|1 +1.3.6.1.2.1.5.30.1.4.2.134|65|0 +1.3.6.1.2.1.5.30.1.4.2.135|65|1 +1.3.6.1.2.1.5.30.1.4.2.136|65|0 +1.3.6.1.2.1.5.30.1.4.2.137|65|0 +1.3.6.1.2.1.5.30.1.4.2.143|65|4 +1.3.6.1.2.1.6.5.0|65|17211997 +1.3.6.1.2.1.6.6.0|65|13094042 +1.3.6.1.2.1.6.7.0|65|3105 +1.3.6.1.2.1.6.8.0|65|3608027 +1.3.6.1.2.1.6.9.0|66|303 +1.3.6.1.2.1.6.10.0|65|4089501013 +1.3.6.1.2.1.6.11.0|65|4113932041 +1.3.6.1.2.1.6.12.0|65|11739 +1.3.6.1.2.1.6.14.0|65|44 +1.3.6.1.2.1.6.15.0|65|3674727 +1.3.6.1.2.1.6.18.0|70|4113932041 +1.3.6.1.2.1.6.19.1.7.1.4.10.10.101.30.42160.1.4.10.10.101.32.443|2|5 +1.3.6.1.2.1.7.1.0|65|84879013 +1.3.6.1.2.1.7.2.0|65|1539 +1.3.6.1.2.1.7.3.0|65|0 +1.3.6.1.2.1.7.4.0|65|82165442 +1.3.6.1.2.1.11.1.0|65|2043212 +1.3.6.1.2.1.11.2.0|65|2043212 +1.3.6.1.2.1.11.3.0|65|0 +1.3.6.1.2.1.11.4.0|65|0 +1.3.6.1.2.1.11.5.0|65|0 +1.3.6.1.2.1.11.6.0|65|0 +1.3.6.1.2.1.11.8.0|65|0 +1.3.6.1.2.1.11.9.0|65|0 +1.3.6.1.2.1.11.10.0|65|0 +1.3.6.1.2.1.11.11.0|65|0 +1.3.6.1.2.1.11.12.0|65|0 +1.3.6.1.2.1.11.13.0|65|15251274 +1.3.6.1.2.1.11.15.0|65|554020 +1.3.6.1.2.1.11.16.0|65|121626 +1.3.6.1.2.1.11.17.0|65|0 +1.3.6.1.2.1.11.18.0|65|0 +1.3.6.1.2.1.11.19.0|65|0 +1.3.6.1.2.1.11.20.0|65|0 +1.3.6.1.2.1.11.21.0|65|0 +1.3.6.1.2.1.11.22.0|65|0 +1.3.6.1.2.1.11.24.0|65|0 +1.3.6.1.2.1.11.25.0|65|0 +1.3.6.1.2.1.11.26.0|65|0 +1.3.6.1.2.1.11.27.0|65|0 +1.3.6.1.2.1.11.28.0|65|2043213 +1.3.6.1.2.1.11.29.0|65|1 +1.3.6.1.2.1.11.31.0|65|0 +1.3.6.1.2.1.11.32.0|65|0 +1.3.6.1.2.1.25.1.1.0|67|910962400 +1.3.6.1.2.1.25.1.5.0|66|0 +1.3.6.1.2.1.25.1.6.0|66|175 +1.3.6.1.2.1.25.2.3.1.1.1|2|1 +1.3.6.1.2.1.25.2.3.1.1.2|2|2 +1.3.6.1.2.1.25.2.3.1.1.3|2|3 +1.3.6.1.2.1.25.2.3.1.1.4|2|4 +1.3.6.1.2.1.25.2.3.1.1.5|2|5 +1.3.6.1.2.1.25.2.3.1.1.6|2|6 +1.3.6.1.2.1.25.2.3.1.1.7|2|7 +1.3.6.1.2.1.25.2.3.1.1.8|2|8 +1.3.6.1.2.1.25.2.3.1.1.9|2|9 +1.3.6.1.2.1.25.2.3.1.1.10|2|10 +1.3.6.1.2.1.25.2.3.1.1.11|2|11 +1.3.6.1.2.1.25.2.3.1.1.12|2|12 +1.3.6.1.2.1.25.2.3.1.1.13|2|13 +1.3.6.1.2.1.25.2.3.1.1.14|2|14 +1.3.6.1.2.1.25.2.3.1.1.15|2|15 +1.3.6.1.2.1.25.2.3.1.1.16|2|16 +1.3.6.1.2.1.25.2.3.1.1.17|2|17 +1.3.6.1.2.1.25.2.3.1.1.18|2|18 +1.3.6.1.2.1.25.2.3.1.1.19|2|19 +1.3.6.1.2.1.25.2.3.1.1.20|2|20 +1.3.6.1.2.1.25.2.3.1.1.21|2|21 +1.3.6.1.2.1.25.2.3.1.2.1|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.2|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.3|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.4|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.5|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.6|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.7|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.8|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.9|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.10|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.11|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.12|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.13|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.14|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.15|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.16|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.17|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.18|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.19|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.20|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.2.21|6|1.3.6.1.2.1.25.2.1.4 +1.3.6.1.2.1.25.2.3.1.3.1|4|/dev +1.3.6.1.2.1.25.2.3.1.3.2|4|/dev/shm +1.3.6.1.2.1.25.2.3.1.3.3|4|/run +1.3.6.1.2.1.25.2.3.1.3.4|4|/sys/fs/cgroup +1.3.6.1.2.1.25.2.3.1.3.5|4|/ +1.3.6.1.2.1.25.2.3.1.3.6|4|/tmp +1.3.6.1.2.1.25.2.3.1.3.7|4|/boot +1.3.6.1.2.1.25.2.3.1.3.8|4|/storage/vtsdblog +1.3.6.1.2.1.25.2.3.1.3.9|4|/storage/lifecycle +1.3.6.1.2.1.25.2.3.1.3.10|4|/storage/imagebuilder +1.3.6.1.2.1.25.2.3.1.3.11|4|/storage/archive +1.3.6.1.2.1.25.2.3.1.3.12|4|/storage/vtsdb +1.3.6.1.2.1.25.2.3.1.3.13|4|/storage/updatemgr +1.3.6.1.2.1.25.2.3.1.3.14|4|/storage/netdump +1.3.6.1.2.1.25.2.3.1.3.15|4|/storage/db +1.3.6.1.2.1.25.2.3.1.3.16|4|/storage/autodeploy +1.3.6.1.2.1.25.2.3.1.3.17|4|/storage/seat +1.3.6.1.2.1.25.2.3.1.3.18|4|/storage/dblog +1.3.6.1.2.1.25.2.3.1.3.19|4|/storage/log +1.3.6.1.2.1.25.2.3.1.3.20|4|/storage/core +1.3.6.1.2.1.25.2.3.1.3.21|4|/var/spool/snmp +1.3.6.1.2.1.25.2.3.1.4.1|2|4096 +1.3.6.1.2.1.25.2.3.1.4.2|2|4096 +1.3.6.1.2.1.25.2.3.1.4.3|2|4096 +1.3.6.1.2.1.25.2.3.1.4.4|2|4096 +1.3.6.1.2.1.25.2.3.1.4.5|2|4096 +1.3.6.1.2.1.25.2.3.1.4.6|2|4096 +1.3.6.1.2.1.25.2.3.1.4.7|2|1024 +1.3.6.1.2.1.25.2.3.1.4.8|2|4096 +1.3.6.1.2.1.25.2.3.1.4.9|2|4096 +1.3.6.1.2.1.25.2.3.1.4.10|2|4096 +1.3.6.1.2.1.25.2.3.1.4.11|2|4096 +1.3.6.1.2.1.25.2.3.1.4.12|2|4096 +1.3.6.1.2.1.25.2.3.1.4.13|2|4096 +1.3.6.1.2.1.25.2.3.1.4.14|2|4096 +1.3.6.1.2.1.25.2.3.1.4.15|2|4096 +1.3.6.1.2.1.25.2.3.1.4.16|2|4096 +1.3.6.1.2.1.25.2.3.1.4.17|2|4096 +1.3.6.1.2.1.25.2.3.1.4.18|2|4096 +1.3.6.1.2.1.25.2.3.1.4.19|2|4096 +1.3.6.1.2.1.25.2.3.1.4.20|2|4096 +1.3.6.1.2.1.25.2.3.1.4.21|2|4096 +1.3.6.1.2.1.25.2.3.1.5.1|2|1533349 +1.3.6.1.2.1.25.2.3.1.5.2|2|1535585 +1.3.6.1.2.1.25.2.3.1.5.3|2|1535585 +1.3.6.1.2.1.25.2.3.1.5.4|2|1535585 +1.3.6.1.2.1.25.2.3.1.5.5|2|12028850 +1.3.6.1.2.1.25.2.3.1.5.6|2|1535585 +1.3.6.1.2.1.25.2.3.1.5.7|2|122835 +1.3.6.1.2.1.25.2.3.1.5.8|2|1271712 +1.3.6.1.2.1.25.2.3.1.5.9|2|25669870 +1.3.6.1.2.1.25.2.3.1.5.10|2|2561861 +1.3.6.1.2.1.25.2.3.1.5.11|2|12833912 +1.3.6.1.2.1.25.2.3.1.5.12|2|2561861 +1.3.6.1.2.1.25.2.3.1.5.13|2|25669870 +1.3.6.1.2.1.25.2.3.1.5.14|2|251910 +1.3.6.1.2.1.25.2.3.1.5.15|2|2561861 +1.3.6.1.2.1.25.2.3.1.5.16|2|2561861 +1.3.6.1.2.1.25.2.3.1.5.17|2|2561861 +1.3.6.1.2.1.25.2.3.1.5.18|2|3852018 +1.3.6.1.2.1.25.2.3.1.5.19|2|2561861 +1.3.6.1.2.1.25.2.3.1.5.20|2|6415929 +1.3.6.1.2.1.25.2.3.1.5.21|2|256 +1.3.6.1.2.1.25.2.3.1.6.1|2|0 +1.3.6.1.2.1.25.2.3.1.6.2|2|234 +1.3.6.1.2.1.25.2.3.1.6.3|2|297 +1.3.6.1.2.1.25.2.3.1.6.4|2|0 +1.3.6.1.2.1.25.2.3.1.6.5|2|2472981 +1.3.6.1.2.1.25.2.3.1.6.6|2|1186 +1.3.6.1.2.1.25.2.3.1.6.7|2|27544 +1.3.6.1.2.1.25.2.3.1.6.8|2|13305 +1.3.6.1.2.1.25.2.3.1.6.9|2|616410 +1.3.6.1.2.1.25.2.3.1.6.10|2|9225 +1.3.6.1.2.1.25.2.3.1.6.11|2|11550862 +1.3.6.1.2.1.25.2.3.1.6.12|2|17196 +1.3.6.1.2.1.25.2.3.1.6.13|2|1437210 +1.3.6.1.2.1.25.2.3.1.6.14|2|636 +1.3.6.1.2.1.25.2.3.1.6.15|2|115461 +1.3.6.1.2.1.25.2.3.1.6.16|2|9224 +1.3.6.1.2.1.25.2.3.1.6.17|2|973770 +1.3.6.1.2.1.25.2.3.1.6.18|2|38921 +1.3.6.1.2.1.25.2.3.1.6.19|2|1349166 +1.3.6.1.2.1.25.2.3.1.6.20|2|116267 +1.3.6.1.2.1.25.2.3.1.6.21|2|0 +1.3.6.1.2.1.25.2.3.1.7.1|65|0 +1.3.6.1.2.1.25.2.3.1.7.2|65|0 +1.3.6.1.2.1.25.2.3.1.7.3|65|0 +1.3.6.1.2.1.25.2.3.1.7.4|65|0 +1.3.6.1.2.1.25.2.3.1.7.5|65|0 +1.3.6.1.2.1.25.2.3.1.7.6|65|0 +1.3.6.1.2.1.25.2.3.1.7.7|65|0 +1.3.6.1.2.1.25.2.3.1.7.8|65|0 +1.3.6.1.2.1.25.2.3.1.7.9|65|0 +1.3.6.1.2.1.25.2.3.1.7.10|65|0 +1.3.6.1.2.1.25.2.3.1.7.11|65|0 +1.3.6.1.2.1.25.2.3.1.7.12|65|0 +1.3.6.1.2.1.25.2.3.1.7.13|65|0 +1.3.6.1.2.1.25.2.3.1.7.14|65|0 +1.3.6.1.2.1.25.2.3.1.7.15|65|0 +1.3.6.1.2.1.25.2.3.1.7.16|65|0 +1.3.6.1.2.1.25.2.3.1.7.17|65|0 +1.3.6.1.2.1.25.2.3.1.7.18|65|0 +1.3.6.1.2.1.25.2.3.1.7.19|65|0 +1.3.6.1.2.1.25.2.3.1.7.20|65|0 +1.3.6.1.2.1.25.2.3.1.7.21|65|0 +1.3.6.1.2.1.25.3.2.1.1.1|2|1 +1.3.6.1.2.1.25.3.2.1.1.2|2|2 +1.3.6.1.2.1.25.3.2.1.1.3|2|3 +1.3.6.1.2.1.25.3.2.1.1.4|2|4 +1.3.6.1.2.1.25.3.2.1.1.5|2|5 +1.3.6.1.2.1.25.3.2.1.1.6|2|6 +1.3.6.1.2.1.25.3.2.1.1.7|2|7 +1.3.6.1.2.1.25.3.2.1.1.8|2|8 +1.3.6.1.2.1.25.3.2.1.1.9|2|9 +1.3.6.1.2.1.25.3.2.1.1.10|2|10 +1.3.6.1.2.1.25.3.2.1.1.11|2|11 +1.3.6.1.2.1.25.3.2.1.1.12|2|12 +1.3.6.1.2.1.25.3.2.1.1.13|2|13 +1.3.6.1.2.1.25.3.2.1.1.14|2|14 +1.3.6.1.2.1.25.3.2.1.1.15|2|15 +1.3.6.1.2.1.25.3.2.1.1.16|2|16 +1.3.6.1.2.1.25.3.2.1.1.17|2|17 +1.3.6.1.2.1.25.3.2.1.1.18|2|18 +1.3.6.1.2.1.25.3.2.1.1.19|2|19 +1.3.6.1.2.1.25.3.2.1.1.20|2|20 +1.3.6.1.2.1.25.3.2.1.2.1|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.2|6|1.3.6.1.2.1.25.3.1.3 +1.3.6.1.2.1.25.3.2.1.2.3|6|1.3.6.1.2.1.25.3.1.4 +1.3.6.1.2.1.25.3.2.1.2.4|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.5|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.6|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.7|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.8|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.9|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.10|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.11|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.12|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.13|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.14|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.15|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.16|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.17|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.18|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.19|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.2.20|6|1.3.6.1.2.1.25.3.1.6 +1.3.6.1.2.1.25.3.2.1.3.1|4|CPU Pkg/ID/Node: 0/0/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GHz +1.3.6.1.2.1.25.3.2.1.3.2|4|CPU Pkg/ID/Node: 0/1/0 Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GHz +1.3.6.1.2.1.25.3.2.1.3.3|4x|4E494320657468302C206472697665720a3230203736203644203738203645203635203734203333203243203230203736203635203732203733203639203646200a3645203341203230203331203245203334203245203331203336203245203330203244203642203244203445203431200a353020343920324320323020333020333020333020333020334120333020333320334120333020333020324520303020 +1.3.6.1.2.1.25.3.2.1.3.4|4|LUN VMware Virtual_disk 1.0 sda +1.3.6.1.2.1.25.3.2.1.3.5|4|LUN VMware Virtual_disk 1.0 sdb +1.3.6.1.2.1.25.3.2.1.3.6|4|LUN VMware LVM PV 8frnGL- 1.0 sdc +1.3.6.1.2.1.25.3.2.1.3.7|4|LUN VMware LVM PV XLuEo6- 1.0 sdd +1.3.6.1.2.1.25.3.2.1.3.8|4|LUN VMware LVM PV A6Uz4j- 1.0 sde +1.3.6.1.2.1.25.3.2.1.3.9|4|LUN VMware LVM PV VyCd9w- 1.0 sdf +1.3.6.1.2.1.25.3.2.1.3.10|4|LUN VMware LVM PV o1ONgp- 1.0 sdg +1.3.6.1.2.1.25.3.2.1.3.11|4|LUN VMware LVM PV hjIMdY- 1.0 sdh +1.3.6.1.2.1.25.3.2.1.3.12|4|LUN VMware LVM PV ge10u7- 1.0 sdi +1.3.6.1.2.1.25.3.2.1.3.13|4|LUN VMware LVM PV pvFiMZ- 1.0 sdj +1.3.6.1.2.1.25.3.2.1.3.14|4|LUN VMware LVM PV T8IOhr- 1.0 sdk +1.3.6.1.2.1.25.3.2.1.3.15|4|LUN VMware LVM PV DuDcyM- 1.0 sdl +1.3.6.1.2.1.25.3.2.1.3.16|4|LUN VMware LVM PV n6NfL2- 1.0 sdm +1.3.6.1.2.1.25.3.2.1.3.17|4|LUN VMware LVM PV vdVUlB- 1.0 sdn +1.3.6.1.2.1.25.3.2.1.3.18|4|LUN VMware LVM PV pC9YhT- 1.0 sdo +1.3.6.1.2.1.25.3.2.1.3.19|4|LUN VMware LVM PV 6tJMy9- 1.0 sdp +1.3.6.1.2.1.25.3.2.1.3.20|4|LUN VMware_Virtual_IDE_CDROM_Drive 00000001 sr0 +1.3.6.1.2.1.25.3.2.1.4.1|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.2|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.3|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.4|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.5|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.6|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.7|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.8|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.9|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.10|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.11|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.12|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.13|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.14|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.15|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.16|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.17|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.18|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.19|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.4.20|6|0.0.0 +1.3.6.1.2.1.25.3.2.1.5.1|2|1 +1.3.6.1.2.1.25.3.2.1.5.2|2|1 +1.3.6.1.2.1.25.3.2.1.5.3|2|1 +1.3.6.1.2.1.25.3.2.1.5.4|2|1 +1.3.6.1.2.1.25.3.2.1.5.5|2|1 +1.3.6.1.2.1.25.3.2.1.5.6|2|1 +1.3.6.1.2.1.25.3.2.1.5.7|2|1 +1.3.6.1.2.1.25.3.2.1.5.8|2|1 +1.3.6.1.2.1.25.3.2.1.5.9|2|1 +1.3.6.1.2.1.25.3.2.1.5.10|2|1 +1.3.6.1.2.1.25.3.2.1.5.11|2|1 +1.3.6.1.2.1.25.3.2.1.5.12|2|1 +1.3.6.1.2.1.25.3.2.1.5.13|2|1 +1.3.6.1.2.1.25.3.2.1.5.14|2|1 +1.3.6.1.2.1.25.3.2.1.5.15|2|1 +1.3.6.1.2.1.25.3.2.1.5.16|2|1 +1.3.6.1.2.1.25.3.2.1.5.17|2|1 +1.3.6.1.2.1.25.3.2.1.5.18|2|1 +1.3.6.1.2.1.25.3.2.1.5.19|2|1 +1.3.6.1.2.1.25.3.2.1.5.20|2|1 +1.3.6.1.2.1.25.3.2.1.6.1|65|0 +1.3.6.1.2.1.25.3.2.1.6.2|65|0 +1.3.6.1.2.1.25.3.2.1.6.3|65|0 +1.3.6.1.2.1.25.3.2.1.6.4|65|0 +1.3.6.1.2.1.25.3.2.1.6.5|65|0 +1.3.6.1.2.1.25.3.2.1.6.6|65|0 +1.3.6.1.2.1.25.3.2.1.6.7|65|0 +1.3.6.1.2.1.25.3.2.1.6.8|65|0 +1.3.6.1.2.1.25.3.2.1.6.9|65|0 +1.3.6.1.2.1.25.3.2.1.6.10|65|0 +1.3.6.1.2.1.25.3.2.1.6.11|65|0 +1.3.6.1.2.1.25.3.2.1.6.12|65|0 +1.3.6.1.2.1.25.3.2.1.6.13|65|0 +1.3.6.1.2.1.25.3.2.1.6.14|65|0 +1.3.6.1.2.1.25.3.2.1.6.15|65|0 +1.3.6.1.2.1.25.3.2.1.6.16|65|0 +1.3.6.1.2.1.25.3.2.1.6.17|65|0 +1.3.6.1.2.1.25.3.2.1.6.18|65|0 +1.3.6.1.2.1.25.3.2.1.6.19|65|0 +1.3.6.1.2.1.25.3.2.1.6.20|65|0 +1.3.6.1.2.1.25.3.3.1.1.1|6|0.0.0 +1.3.6.1.2.1.25.3.3.1.1.2|6|0.0.0 +1.3.6.1.2.1.25.3.3.1.2.1|2|7 +1.3.6.1.2.1.25.3.3.1.2.2|2|6 +1.3.6.1.2.1.47.1.1.1.1.2.1|4|CloudVM Intel Corporation 440BX Desktop Reference Platform Intel Corporation +1.3.6.1.2.1.47.1.1.1.1.3.1|6|0.0.0 +1.3.6.1.2.1.47.1.1.1.1.4.1|2|0 +1.3.6.1.2.1.47.1.1.1.1.5.1|2|1 +1.3.6.1.2.1.47.1.1.1.1.6.1|2|-1 +1.3.6.1.2.1.47.1.1.1.1.7.1|4|vcsa.foobar.local +1.3.6.1.2.1.47.1.1.1.1.8.1|4|N/A +1.3.6.1.2.1.47.1.1.1.1.9.1|4|6.00 +1.3.6.1.2.1.47.1.1.1.1.10.1|4|4.19.115-1.ph3- +1.3.6.1.2.1.47.1.1.1.1.11.1|4|VMware-43 1c 58 a2 1c d4 34 54-7 +1.3.6.1.2.1.47.1.1.1.1.12.1|4|VMware, Inc. +1.3.6.1.2.1.47.1.1.1.1.13.1|4|VMware Virtual Platform +1.3.6.1.2.1.47.1.1.1.1.14.1|4|VMware, Inc. VMware, Inc. +1.3.6.1.2.1.47.1.1.1.1.15.1|4|No Asset Tag +1.3.6.1.2.1.47.1.1.1.1.16.1|2|2 +1.3.6.1.2.1.47.1.1.1.1.17.1|4x|07E2070300000000000000 +1.3.6.1.2.1.47.1.1.1.1.18.1|4|urn:uuid:711a12b446d41791749d28fb5a5e37af +1.3.6.1.4.1.6876.1.1.0|4|VMware-vCenter-Server-Appliance +1.3.6.1.4.1.6876.1.2.0|4|7.0.0.10100 +1.3.6.1.4.1.6876.1.4.0|4|16386292 diff --git a/tests/snmpsim/vmware_esx.snmprec b/tests/snmpsim/vmware_esx.snmprec deleted file mode 100644 index 58ede4049d..0000000000 --- a/tests/snmpsim/vmware_esx.snmprec +++ /dev/null @@ -1,2 +0,0 @@ -1.3.6.1.2.1.1.1.0|4|VMware ESXi 6.5.0 build-4564106 VMware, Inc. x86_64 -1.3.6.1.2.1.1.2.0|6|1.3.6.1.4.1.6876.4.1 diff --git a/tests/snmpsim/vmware_vcenter.snmprec b/tests/snmpsim/vmware_vcenter.snmprec deleted file mode 100644 index ae4c5d3323..0000000000 --- a/tests/snmpsim/vmware_vcenter.snmprec +++ /dev/null @@ -1,2 +0,0 @@ -1.3.6.1.2.1.1.1.0|4|VMware vCenter Server Appliance 6.7.0.20000 embedded build 10244745 VMware, Inc. x86_64 -1.3.6.1.2.1.1.2.0|6|1.3.6.1.4.1.6876.4.7 diff --git a/tests/snmpsim/vmware_vcsa.snmprec b/tests/snmpsim/vmware_vcsa.snmprec deleted file mode 100644 index 2c4758fb9d..0000000000 --- a/tests/snmpsim/vmware_vcsa.snmprec +++ /dev/null @@ -1,2 +0,0 @@ -1.3.6.1.2.1.1.1.0|4|VMware-vCenter-Server-Appliance 6.5.0.5100 embedded build 4602587 VMware, Inc x86_64 -1.3.6.1.2.1.1.2.0|6|1.3.6.1.4.1.6876.4.7