diff --git a/includes/definitions/algcom-dc-ups.yaml b/includes/definitions/algcom-dc-ups.yaml
new file mode 100644
index 0000000000..9d1aca7298
--- /dev/null
+++ b/includes/definitions/algcom-dc-ups.yaml
@@ -0,0 +1,14 @@
+os: algcom-dc-ups
+text: 'ALGCOM DC UPS'
+type: power
+icon: algcom
+
+over:
+ - { graph: device_current, text: Current }
+ - { graph: device_voltage, text: Voltage }
+ - { graph: device_temperature, text: Temperature }
+
+discovery:
+ - sysObjectID:
+ - .1.3.6.1.4.1.49136
+mib_dir: algcom
diff --git a/includes/definitions/discovery/algcom-dc-ups.yaml b/includes/definitions/discovery/algcom-dc-ups.yaml
new file mode 100644
index 0000000000..8eb077f817
--- /dev/null
+++ b/includes/definitions/discovery/algcom-dc-ups.yaml
@@ -0,0 +1,169 @@
+mib: ALGPOWER-v2-MIB
+modules:
+ sensors:
+ voltage:
+ data:
+ -
+ oid: outputVoltage
+ num_oid: '.1.3.6.1.4.1.49136.1.1.1.{{ $index }}'
+ divisor: 10
+ descr: 'DC Voltage'
+ index: outputVoltage
+ -
+ oid: batteryVoltage
+ num_oid: '.1.3.6.1.4.1.49136.1.2.1.{{ $index }}'
+ divisor: 10
+ descr: 'Battery Voltage'
+ index: batteryVoltage
+ -
+ oid: supplyVoltage
+ num_oid: '.1.3.6.1.4.1.49136.1.6.1.{{ $index }}'
+ divisor: 10
+ descr: 'AC Voltage (Optional)'
+ index: supplyVoltage
+ -
+ oid: btst-volt-i
+ num_oid: '.1.3.6.1.4.1.49136.1.8.5.{{ $index }}'
+ divisor: 10
+ descr: 'Bat-test initial'
+ index: btst-volt-i
+ -
+ oid: btst-volt-f
+ num_oid: '.1.3.6.1.4.1.49136.1.8.7.{{ $index }}'
+ divisor: 10
+ descr: 'Bat-test final'
+ index: btst-volt-f
+ current:
+ data:
+ -
+ oid: outputCurrent
+ num_oid: '.1.3.6.1.4.1.49136.1.1.2.{{ $index }}'
+ divisor: 1000
+ descr: 'Total output current'
+ index: outputCurrent
+ -
+ oid: batteryCurrent
+ num_oid: '.1.3.6.1.4.1.49136.1.2.2.{{ $index }}'
+ divisor: 1000
+ descr: 'Battery current'
+ index: batteryCurrent
+ -
+ oid: btst-amp-i
+ num_oid: '.1.3.6.1.4.1.49136.1.8.6.{{ $index }}'
+ divisor: 1000
+ descr: 'Bat-test initial'
+ index: btst-amp-i
+ -
+ oid: btst-amp-f
+ num_oid: '.1.3.6.1.4.1.49136.1.8.8.{{ $index }}'
+ divisor: 1000
+ descr: 'Bat-test final'
+ index: btst-amp-f
+ temperature:
+ data:
+ -
+ oid: innerTemperature
+ num_oid: '.1.3.6.1.4.1.49136.1.4.1.{{ $index }}'
+ multiplier: 1
+ descr: 'Internal temperature'
+ index: innerTemperature
+ -
+ oid: outerTemperature
+ num_oid: '.1.3.6.1.4.1.49136.1.4.2.{{ $index }}'
+ multiplier: 1
+ descr: 'External probe temperature'
+ index: outerTemperature
+ -
+ oid: heatSinkTemperature
+ num_oid: '.1.3.6.1.4.1.49136.1.4.3.{{ $index }}'
+ multiplier: 1
+ descr: 'Heatsink temperature'
+ index: heatSinkTemperature
+ state:
+ data:
+ -
+ oid: chargerStatus
+ num_oid: '.1.3.6.1.4.1.49136.1.2.3.{{ $index }}'
+ descr: 'Charger Status'
+ index: chargerStatus
+ states:
+ - { graph: 1, value: 0, generic: 2, descr: BATTERY_DISCONNECTED }
+ - { graph: 1, value: 1, generic: 2, descr: WRONG_BATTERY_VOLTAGE }
+ - { graph: 1, value: 2, generic: 1, descr: DISCHARGING }
+ - { graph: 1, value: 3, generic: 0, descr: CHARGING_BULK }
+ - { graph: 1, value: 4, generic: 0, descr: CHARGING_ABSORPTION }
+ - { graph: 1, value: 5, generic: 0, descr: CHARGING_FLOAT }
+ - { graph: 1, value: 6, generic: 2, descr: CRITICAL_LOW_VOLTAGE }
+ - { graph: 1, value: 7, generic: 0, descr: BATTERY_UNDER_TEST }
+ -
+ oid: alarmOnBattery
+ num_oid: '.1.3.6.1.4.1.49136.1.3.1.{{ $index }}'
+ descr: 'Operation Mode'
+ index: alarmOnBattery
+ states:
+ - { graph: 1, value: 0, generic: 0, descr: AC }
+ - { graph: 1, value: 1, generic: 1, descr: BATTERY }
+ -
+ oid: acFail
+ num_oid: '.1.3.6.1.4.1.49136.1.3.2.{{ $index }}'
+ descr: 'AC Power'
+ index: acFail
+ states:
+ - { graph: 1, value: 0, generic: 0, descr: OK }
+ - { graph: 1, value: 1, generic: 1, descr: FAIL }
+ -
+ oid: batteryCharging
+ num_oid: '.1.3.6.1.4.1.49136.1.3.3.{{ $index }}'
+ descr: 'Charging'
+ index: batteryCharging
+ states:
+ - { graph: 1, value: 0, generic: 0, descr: NO }
+ - { graph: 1, value: 1, generic: 0, descr: YES }
+ -
+ oid: batteryDischarging
+ num_oid: '.1.3.6.1.4.1.49136.1.3.4.{{ $index }}'
+ descr: 'Discharging'
+ index: batteryDischarging
+ states:
+ - { graph: 1, value: 0, generic: 0, descr: NO }
+ - { graph: 1, value: 1, generic: 0, descr: YES }
+ -
+ oid: overheat
+ num_oid: '.1.3.6.1.4.1.49136.1.3.5.{{ $index }}'
+ descr: 'Temperature Status'
+ index: overheat
+ states:
+ - { graph: 1, value: 0, generic: 0, descr: OK }
+ - { graph: 1, value: 1, generic: 2, descr: OVERHEAT }
+ -
+ oid: overload
+ num_oid: '.1.3.6.1.4.1.49136.1.3.6.{{ $index }}'
+ descr: 'Load Capacity'
+ index: overload
+ states:
+ - { graph: 1, value: 0, generic: 0, descr: OK }
+ - { graph: 1, value: 1, generic: 2, descr: OVERLOAD }
+ -
+ oid: fanAfail
+ num_oid: '.1.3.6.1.4.1.49136.1.3.7.{{ $index }}'
+ descr: 'Fan A'
+ index: fanAfail
+ states:
+ - { graph: 0, value: 0, generic: 0, descr: OK }
+ - { graph: 0, value: 1, generic: 2, descr: FAIL }
+ -
+ oid: fanBfail
+ num_oid: '.1.3.6.1.4.1.49136.1.3.8.{{ $index }}'
+ descr: 'Fan B'
+ index: fanBfail
+ states:
+ - { graph: 0, value: 0, generic: 0, descr: OK }
+ - { graph: 0, value: 1, generic: 2, descr: FAIL }
+ count:
+ data:
+ -
+ oid: upTime
+ num_oid: '.1.3.6.1.4.1.49136.1.3.11.{{ $index }}'
+ descr: 'Horimeter'
+ multiplier: 1
+ index: upTime
diff --git a/mibs/algcom/ALGPOWER-v2 b/mibs/algcom/ALGPOWER-v2
new file mode 100644
index 0000000000..40e0891b19
--- /dev/null
+++ b/mibs/algcom/ALGPOWER-v2
@@ -0,0 +1,590 @@
+ALGPOWER-v2-MIB DEFINITIONS ::= BEGIN
+ IMPORTS
+ DisplayString FROM RFC1213-MIB
+ OBJECT-TYPE FROM RFC-1212
+ enterprises FROM RFC1155-SMI;
+
+ algcom OBJECT IDENTIFIER ::= { enterprises 49136 }
+ upsObjects OBJECT IDENTIFIER ::= { algcom 1 }
+ output OBJECT IDENTIFIER ::= { upsObjects 1 }
+ battery OBJECT IDENTIFIER ::= { upsObjects 2 }
+ input OBJECT IDENTIFIER ::= { upsObjects 3 }
+ temperature OBJECT IDENTIFIER ::= { upsObjects 4 }
+ watchdog OBJECT IDENTIFIER ::= { upsObjects 5 }
+ supply OBJECT IDENTIFIER ::= { upsObjects 6 }
+ installation OBJECT IDENTIFIER ::= { upsObjects 7 }
+ bat-tst OBJECT IDENTIFIER ::= { upsObjects 8 }
+
+
+ outputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Numeric value of instantaneous output voltage from
+ the source in tenths of a volt. To get the value
+ actual in volt should be divided by 10.
+
+ Example:
+ Read value 241, actual value 24.1V."
+ ::= { output 1 }
+
+ outputCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Numeric value of current output of converter AC/DC.
+ Real value reading in milli ampere.
+
+ Example:
+ Read value 1087, Actual value 1.087 milli ampere
+ or 1.087A.
+ If the output is '0' the AC/DC is off and the output
+ for the equipments is provide from batteries"
+ ::= { output 2 }
+
+ oidNotUsed0 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "OID not used."
+ ::= { output 3 }
+
+ oidNotUsed1 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "OID not used."
+ ::= { output 4 }
+
+
+ batteryVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Numeric value of instantaneous voltage of battery bank.
+ To get the actual value in volt must be divided by 10.
+
+ Example:
+ Read value 240, actual value 24.0V."
+ ::= { battery 1 }
+
+ batteryCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Numeric value of current in Battery bank. Real
+ value reading in milli ampere.
+ If the value is negative the Battery bank is provide
+ energy for the output.
+ If the value is positive the Battery bank is under
+ charger
+
+ Example:
+ Read value -2230, Actual value 2,230 ampere and the
+ battery bank is provide this current.
+ Read value 3000, Actual value 3.000 milli ampere and
+ the battery bank is absorve this current."
+ ::= { battery 2 }
+
+ chargerStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Show the status of battery charger:
+ 0 - The battery is not connected in DC UPS;
+ 1 - The battery is voltage incompatible with DC UPS;
+ 2 - The DC UPS is in nobreak mode;
+ 3 - The charger of Battery is in Bulk stage;
+ 4 - The charger of Battery is Absorption stage;
+ 5 - The charger of Battery is Float stage;
+ 6 - The Battery will be disconnected in 30s due to
+ low voltage and the DC-UPS output will be
+ turned off.
+ 7 - The Battery is under test"
+ ::= { battery 3 }
+
+
+ alarmOnBattery OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Shows the operation mode of DC-UPS:
+
+ 0 - The DC-UPS output is provide by AC energy.
+ 1 - The DC-UPS output is provide by Battery"
+ ::= { input 1 }
+
+ acFail OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm that alert about AC outages in the last 10
+ minutes:
+
+ 0 - DC-UPS in normal operation.
+ 1 - Occur a AC fail in the last 10 minutes."
+ ::= { input 2 }
+
+ batteryCharging OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Show the status of charging Battery:
+
+ 1 - The battery is on charging.
+ 0 - The battery is on discharging."
+ ::= { input 3 }
+
+ batteryDischarging OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Show the status of discharging Battery:
+
+ 1 - The battery is on discharging.
+ 0 - The battery is on charging."
+ ::= { input 4 }
+
+ overheat OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm that alert about overtemperature of DC-UPS
+
+ 1 - The DC-UPS is in condition of overtemperature.
+ 0 - The DC-UPS is in normal condition."
+ ::= { input 5 }
+
+ overload OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm that alert about overload of DC-UPS
+
+ 1 - The DC-UPS is in condition of overload.
+ 0 - The DC-UPS is in normal condition."
+ ::= { input 6 }
+
+ fanAfail OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm that alert about fail in internal FAN A
+
+ 1 - Internal FAN with fail.
+ 0 - Internal FAN ok"
+ ::= { input 7 }
+
+ fanBfail OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm that alert about fail in internal FAN B
+
+ 1 - Internal FAN with fail.
+ 0 - Internal FAN ok"
+ ::= { input 8 }
+
+ oidNotUsed2 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "OID not used."
+ ::= { input 9 }
+
+ oidNotUsed3 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "OID not used."
+ ::= { input 10 }
+
+ upTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "System Up time in hours"
+ ::= {input 11}
+
+
+ innerTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Show the internal temperature of power supply.
+ Uses the unit degree Celsius.
+
+ Example
+ Read value: 25, temperature is 25degC."
+ ::= { temperature 1 }
+
+ outerTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Show the temperature of external sensor (cable that
+ comes with power supply).
+ Uses the unit degree Celsius.
+
+ Example
+ Read value: 25, temperature is 25degC."
+ ::= { temperature 2 }
+
+ heatSinkTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Show the temperature of sensor in the heatsink of
+ power supply use the unit degree Celsius.
+
+ Example
+ Read value: 25, temperature is 25degC."
+ ::= { temperature 3 }
+
+
+ watchdogPing1 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm indicating the action of watchdog 1
+ programmed in the last 10 minutes. The watchdog
+ acts on the output by turning it off when not
+ receive response from IP ping command
+ configured.
+
+ 1 - The watchdog 1 acted on the output the last 10
+ minutes.
+ 0 - The Watchdog 1 has not acted in the last 10
+ minutes."
+ ::= { watchdog 1 }
+
+ watchdogPing2 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm indicating the action of watchdog 2
+ programmed in the last 10 minutes. The watchdog
+ acts on the output by turning it off when not
+ receive response from IP ping command
+ configured.
+
+ 1 - The watchdog 2 acted on the output the last 10
+ minutes.
+ 0 - The Watchdog 2 has not acted in the last 10
+ minutes."
+ ::= { watchdog 2 }
+
+ watchdogPing3 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm indicating the action of watchdog 3
+ programmed in the last 10 minutes. The watchdog
+ acts on the output by turning it off when not
+ receive response from IP ping command
+ configured.
+
+ 1 - The watchdog 3 acted on the output the last 10
+ minutes.
+ 0 - The Watchdog 3 has not acted in the last 10
+ minutes."
+ ::= { watchdog 3 }
+
+ watchdogPing4 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm indicating the action of watchdog 4
+ programmed in the last 10 minutes. The watchdog
+ acts on the output by turning it off when not
+ receive response from IP ping command
+ configured.
+
+ 1 - The watchdog 4 acted on the output the last 10
+ minutes.
+ 0 - The Watchdog 4 has not acted in the last 10
+ minutes."
+ ::= { watchdog 4 }
+
+ watchdogPing5 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm indicating the action of watchdog 5
+ programmed in the last 10 minutes. The watchdog
+ acts on the output by turning it off when not
+ receive response from IP ping command
+ configured.
+
+ 1 - The watchdog 5 acted on the output the last 10
+ minutes.
+ 0 - The Watchdog 5 has not acted in the last 10
+ minutes."
+ ::= { watchdog 5 }
+
+ watchdogPing6 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm indicating the action of watchdog 6
+ programmed in the last 10 minutes. The watchdog
+ acts on the output by turning it off when not
+ receive response from IP ping command
+ configured.
+
+ 1 - The watchdog 6 acted on the output the last 10
+ minutes.
+ 0 - The Watchdog 6 has not acted in the last 10
+ minutes."
+ ::= { watchdog 6 }
+
+ watchdogPing7 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm indicating the action of watchdog 7
+ programmed in the last 10 minutes. The watchdog
+ acts on the output by turning it off when not
+ receive response from IP ping command
+ configured.
+
+ 1 - The watchdog 7 acted on the output the last 10
+ minutes.
+ 0 - The Watchdog 7 has not acted in the last 10
+ minutes."
+ ::= { watchdog 7 }
+
+ watchdogPing8 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm indicating the action of watchdog 8
+ programmed in the last 10 minutes. The watchdog
+ acts on the output by turning it off when not
+ receive response from IP ping command
+ configured.
+
+ 1 - The watchdog 8 acted on the output the last 10
+ minutes.
+ 0 - The Watchdog 8 has not acted in the last 10
+ minutes."
+ ::= { watchdog 8 }
+
+ watchdogPing9 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm indicating the action of watchdog 9
+ programmed in the last 10 minutes. The watchdog
+ acts on the output by turning it off when not
+ receive response from IP ping command
+ configured.
+
+ 1 - The watchdog 9 acted on the output the last 10
+ minutes.
+ 0 - The Watchdog 9 has not acted in the last 10
+ minutes."
+ ::= { watchdog 9 }
+
+ watchdogPing10 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm indicating the action of watchdog 10
+ programmed in the last 10 minutes. The watchdog
+ acts on the output by turning it off when not
+ receive response from IP ping command
+ configured.
+
+ 1 - The watchdog 10 acted on the output the last 10
+ minutes.
+ 0 - The Watchdog 10 has not acted in the last 10
+ minutes."
+ ::= { watchdog 10 }
+
+
+ supplyVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The supply AC voltage decivolt [dV]
+ Numeric value of instantaneous input voltage.
+ An optional sensor is required to read this value.
+ To get the actual value in volt it should be
+ divided by 10.
+
+ Example:
+ Read value 2410, actual value 241 Vac."
+ ::= {supply 1}
+
+
+ popName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (30))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "PoP name"
+ ::= {installation 1}
+
+ facilityAddr OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (40))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Facility address"
+ ::= {installation 2}
+
+ facilityCity OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (30))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Facility city"
+ ::= {installation 3}
+
+ instDate OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (10))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Installation date"
+ ::= {installation 4}
+
+ batCapacity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Battery capacity"
+ ::= {installation 5}
+
+ batBrand OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (30))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Battery brand"
+ ::= {installation 6}
+
+ batInstDate OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (10))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Battery installation date"
+ ::= {installation 7}
+
+ respPers OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (50))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Responsible person"
+ ::= {installation 8}
+
+ btst-date OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (10))
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Battery test execution date (dd/mm/yyyy)"
+ ::= {bat-tst 1}
+
+ btst-status OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Battery test status
+ 0 - NEVER DONE
+ 1 - Passed
+ 2 - Running
+ 3 - Aborted
+ 4 - Failed"
+ ::= {bat-tst 2}
+
+ btst-duration OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Programmed test duration in minutes
+ * 999 - Perform the test until battery is fully discharged"
+ ::= {bat-tst 3}
+
+ btst-elapsed OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION "Elapsed time in current\last battery test"
+ ::= {bat-tst 4}
+
+ btst-volt-i OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery initial voltage [dV]
+ Numeric value of battery voltage when starting the battery test.
+
+ Example:
+ Read value 241, actual value 24.1 V."
+ ::= {bat-tst 5}
+
+ btst-amp-i OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery initial cuurent [mA]
+ Numeric value of battery current when starting the battery test.
+
+ Example:
+ Read value 1522, actual value 1.55 A."
+ ::= {bat-tst 6}
+
+ btst-volt-f OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery final voltage [dV]
+ Numeric value of battery voltage when the battery test is done.
+
+ Example:
+ Read value 225, actual value 22.5 V."
+ ::= {bat-tst 7}
+
+ btst-amp-f OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The battery initial cuurent [mA]
+ Numeric value of battery current when the battery test is done.
+
+ Example:
+ Read value 1485, actual value 1.48 A."
+ ::= {bat-tst 8}
+
+END
diff --git a/tests/data/algcom-dc-ups.json b/tests/data/algcom-dc-ups.json
new file mode 100644
index 0000000000..42c1bfa76b
--- /dev/null
+++ b/tests/data/algcom-dc-ups.json
@@ -0,0 +1,745 @@
+{
+ "os": {
+ "discovery": {
+ "devices": [
+ {
+ "sysName": "",
+ "sysObjectID": ".1.3.6.1.4.1.49136",
+ "sysDescr": "DC UPS ALGCOM",
+ "sysContact": null,
+ "version": null,
+ "hardware": null,
+ "features": null,
+ "os": "algcom-dc-ups",
+ "type": "power",
+ "serial": null,
+ "icon": "algcom.png",
+ "location": ""
+ }
+ ]
+ },
+ "poller": {
+ "devices": [
+ {
+ "sysName": "",
+ "sysObjectID": ".1.3.6.1.4.1.49136",
+ "sysDescr": "DC UPS ALGCOM",
+ "sysContact": "",
+ "version": null,
+ "hardware": null,
+ "features": null,
+ "os": "algcom-dc-ups",
+ "type": "power",
+ "serial": null,
+ "icon": "algcom.png",
+ "location": ""
+ }
+ ]
+ }
+ },
+ "sensors": {
+ "discovery": {
+ "sensors": [
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "count",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.3.11.0",
+ "sensor_index": "upTime",
+ "sensor_type": "algcom-dc-ups",
+ "sensor_descr": "Horimeter",
+ "group": null,
+ "sensor_divisor": 1,
+ "sensor_multiplier": 1,
+ "sensor_current": 264,
+ "sensor_limit": null,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": null,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": null
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "current",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.2.2.0",
+ "sensor_index": "batteryCurrent",
+ "sensor_type": "algcom-dc-ups",
+ "sensor_descr": "Battery current",
+ "group": null,
+ "sensor_divisor": 1000,
+ "sensor_multiplier": 1,
+ "sensor_current": 0,
+ "sensor_limit": null,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": null,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": null
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "current",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.8.8.0",
+ "sensor_index": "btst-amp-f",
+ "sensor_type": "algcom-dc-ups",
+ "sensor_descr": "Bat-test final",
+ "group": null,
+ "sensor_divisor": 1000,
+ "sensor_multiplier": 1,
+ "sensor_current": -1.897,
+ "sensor_limit": null,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": null,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": null
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "current",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.8.6.0",
+ "sensor_index": "btst-amp-i",
+ "sensor_type": "algcom-dc-ups",
+ "sensor_descr": "Bat-test initial",
+ "group": null,
+ "sensor_divisor": 1000,
+ "sensor_multiplier": 1,
+ "sensor_current": -1.581,
+ "sensor_limit": null,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": null,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": null
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "current",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.1.2.0",
+ "sensor_index": "outputCurrent",
+ "sensor_type": "algcom-dc-ups",
+ "sensor_descr": "Total output current",
+ "group": null,
+ "sensor_divisor": 1000,
+ "sensor_multiplier": 1,
+ "sensor_current": 1.374,
+ "sensor_limit": null,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": null,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": null
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "state",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.3.2.0",
+ "sensor_index": "acFail",
+ "sensor_type": "acFail",
+ "sensor_descr": "AC Power",
+ "group": null,
+ "sensor_divisor": 1,
+ "sensor_multiplier": 1,
+ "sensor_current": 0,
+ "sensor_limit": null,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": null,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": "acFail"
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "state",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.3.1.0",
+ "sensor_index": "alarmOnBattery",
+ "sensor_type": "alarmOnBattery",
+ "sensor_descr": "Operation Mode",
+ "group": null,
+ "sensor_divisor": 1,
+ "sensor_multiplier": 1,
+ "sensor_current": 0,
+ "sensor_limit": null,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": null,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": "alarmOnBattery"
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "state",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.3.3.0",
+ "sensor_index": "batteryCharging",
+ "sensor_type": "batteryCharging",
+ "sensor_descr": "Charging",
+ "group": null,
+ "sensor_divisor": 1,
+ "sensor_multiplier": 1,
+ "sensor_current": 1,
+ "sensor_limit": null,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": null,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": "batteryCharging"
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "state",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.3.4.0",
+ "sensor_index": "batteryDischarging",
+ "sensor_type": "batteryDischarging",
+ "sensor_descr": "Discharging",
+ "group": null,
+ "sensor_divisor": 1,
+ "sensor_multiplier": 1,
+ "sensor_current": 0,
+ "sensor_limit": null,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": null,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": "batteryDischarging"
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "state",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.2.3.0",
+ "sensor_index": "chargerStatus",
+ "sensor_type": "chargerStatus",
+ "sensor_descr": "Charger Status",
+ "group": null,
+ "sensor_divisor": 1,
+ "sensor_multiplier": 1,
+ "sensor_current": 5,
+ "sensor_limit": null,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": null,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": "chargerStatus"
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "state",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.3.7.0",
+ "sensor_index": "fanAfail",
+ "sensor_type": "fanAfail",
+ "sensor_descr": "Fan A",
+ "group": null,
+ "sensor_divisor": 1,
+ "sensor_multiplier": 1,
+ "sensor_current": 0,
+ "sensor_limit": null,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": null,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": "fanAfail"
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "state",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.3.8.0",
+ "sensor_index": "fanBfail",
+ "sensor_type": "fanBfail",
+ "sensor_descr": "Fan B",
+ "group": null,
+ "sensor_divisor": 1,
+ "sensor_multiplier": 1,
+ "sensor_current": 0,
+ "sensor_limit": null,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": null,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": "fanBfail"
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "state",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.3.5.0",
+ "sensor_index": "overheat",
+ "sensor_type": "overheat",
+ "sensor_descr": "Temperature Status",
+ "group": null,
+ "sensor_divisor": 1,
+ "sensor_multiplier": 1,
+ "sensor_current": 0,
+ "sensor_limit": null,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": null,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": "overheat"
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "state",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.3.6.0",
+ "sensor_index": "overload",
+ "sensor_type": "overload",
+ "sensor_descr": "Load Capacity",
+ "group": null,
+ "sensor_divisor": 1,
+ "sensor_multiplier": 1,
+ "sensor_current": 0,
+ "sensor_limit": null,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": null,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": "overload"
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "temperature",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.4.3.0",
+ "sensor_index": "heatSinkTemperature",
+ "sensor_type": "algcom-dc-ups",
+ "sensor_descr": "Heatsink temperature",
+ "group": null,
+ "sensor_divisor": 1,
+ "sensor_multiplier": 1,
+ "sensor_current": 28,
+ "sensor_limit": 48,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": 18,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": null
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "temperature",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.4.1.0",
+ "sensor_index": "innerTemperature",
+ "sensor_type": "algcom-dc-ups",
+ "sensor_descr": "Internal temperature",
+ "group": null,
+ "sensor_divisor": 1,
+ "sensor_multiplier": 1,
+ "sensor_current": 37,
+ "sensor_limit": 57,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": 27,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": null
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "temperature",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.4.2.0",
+ "sensor_index": "outerTemperature",
+ "sensor_type": "algcom-dc-ups",
+ "sensor_descr": "External probe temperature",
+ "group": null,
+ "sensor_divisor": 1,
+ "sensor_multiplier": 1,
+ "sensor_current": 0,
+ "sensor_limit": 20,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": -10,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": null
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "voltage",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.2.1.0",
+ "sensor_index": "batteryVoltage",
+ "sensor_type": "algcom-dc-ups",
+ "sensor_descr": "Battery Voltage",
+ "group": null,
+ "sensor_divisor": 10,
+ "sensor_multiplier": 1,
+ "sensor_current": 53.9,
+ "sensor_limit": 61.985,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": 45.815,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": null
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "voltage",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.8.7.0",
+ "sensor_index": "btst-volt-f",
+ "sensor_type": "algcom-dc-ups",
+ "sensor_descr": "Bat-test final",
+ "group": null,
+ "sensor_divisor": 10,
+ "sensor_multiplier": 1,
+ "sensor_current": 41.9,
+ "sensor_limit": 48.185,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": 35.615,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": null
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "voltage",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.8.5.0",
+ "sensor_index": "btst-volt-i",
+ "sensor_type": "algcom-dc-ups",
+ "sensor_descr": "Bat-test initial",
+ "group": null,
+ "sensor_divisor": 10,
+ "sensor_multiplier": 1,
+ "sensor_current": 51.7,
+ "sensor_limit": 59.455,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": 43.945,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": null
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "voltage",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.1.1.0",
+ "sensor_index": "outputVoltage",
+ "sensor_type": "algcom-dc-ups",
+ "sensor_descr": "DC Voltage",
+ "group": null,
+ "sensor_divisor": 10,
+ "sensor_multiplier": 1,
+ "sensor_current": 53.9,
+ "sensor_limit": 61.985,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": 45.815,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": null
+ },
+ {
+ "sensor_deleted": 0,
+ "sensor_class": "voltage",
+ "poller_type": "snmp",
+ "sensor_oid": ".1.3.6.1.4.1.49136.1.6.1.0",
+ "sensor_index": "supplyVoltage",
+ "sensor_type": "algcom-dc-ups",
+ "sensor_descr": "AC Voltage (Optional)",
+ "group": null,
+ "sensor_divisor": 10,
+ "sensor_multiplier": 1,
+ "sensor_current": 0,
+ "sensor_limit": 0,
+ "sensor_limit_warn": null,
+ "sensor_limit_low": 0,
+ "sensor_limit_low_warn": null,
+ "sensor_alert": 1,
+ "sensor_custom": "No",
+ "entPhysicalIndex": null,
+ "entPhysicalIndex_measured": null,
+ "sensor_prev": null,
+ "user_func": null,
+ "state_name": null
+ }
+ ],
+ "state_indexes": [
+ {
+ "state_name": "acFail",
+ "state_descr": "OK",
+ "state_draw_graph": 1,
+ "state_value": 0,
+ "state_generic_value": 0
+ },
+ {
+ "state_name": "acFail",
+ "state_descr": "FAIL",
+ "state_draw_graph": 1,
+ "state_value": 1,
+ "state_generic_value": 1
+ },
+ {
+ "state_name": "alarmOnBattery",
+ "state_descr": "AC",
+ "state_draw_graph": 1,
+ "state_value": 0,
+ "state_generic_value": 0
+ },
+ {
+ "state_name": "alarmOnBattery",
+ "state_descr": "BATTERY",
+ "state_draw_graph": 1,
+ "state_value": 1,
+ "state_generic_value": 1
+ },
+ {
+ "state_name": "batteryCharging",
+ "state_descr": "NO",
+ "state_draw_graph": 1,
+ "state_value": 0,
+ "state_generic_value": 0
+ },
+ {
+ "state_name": "batteryCharging",
+ "state_descr": "YES",
+ "state_draw_graph": 1,
+ "state_value": 1,
+ "state_generic_value": 0
+ },
+ {
+ "state_name": "batteryDischarging",
+ "state_descr": "NO",
+ "state_draw_graph": 1,
+ "state_value": 0,
+ "state_generic_value": 0
+ },
+ {
+ "state_name": "batteryDischarging",
+ "state_descr": "YES",
+ "state_draw_graph": 1,
+ "state_value": 1,
+ "state_generic_value": 0
+ },
+ {
+ "state_name": "chargerStatus",
+ "state_descr": "BATTERY_DISCONNECTED",
+ "state_draw_graph": 1,
+ "state_value": 0,
+ "state_generic_value": 2
+ },
+ {
+ "state_name": "chargerStatus",
+ "state_descr": "WRONG_BATTERY_VOLTAGE",
+ "state_draw_graph": 1,
+ "state_value": 1,
+ "state_generic_value": 2
+ },
+ {
+ "state_name": "chargerStatus",
+ "state_descr": "DISCHARGING",
+ "state_draw_graph": 1,
+ "state_value": 2,
+ "state_generic_value": 1
+ },
+ {
+ "state_name": "chargerStatus",
+ "state_descr": "CHARGING_BULK",
+ "state_draw_graph": 1,
+ "state_value": 3,
+ "state_generic_value": 0
+ },
+ {
+ "state_name": "chargerStatus",
+ "state_descr": "CHARGING_ABSORPTION",
+ "state_draw_graph": 1,
+ "state_value": 4,
+ "state_generic_value": 0
+ },
+ {
+ "state_name": "chargerStatus",
+ "state_descr": "CHARGING_FLOAT",
+ "state_draw_graph": 1,
+ "state_value": 5,
+ "state_generic_value": 0
+ },
+ {
+ "state_name": "chargerStatus",
+ "state_descr": "CRITICAL_LOW_VOLTAGE",
+ "state_draw_graph": 1,
+ "state_value": 6,
+ "state_generic_value": 2
+ },
+ {
+ "state_name": "chargerStatus",
+ "state_descr": "BATTERY_UNDER_TEST",
+ "state_draw_graph": 1,
+ "state_value": 7,
+ "state_generic_value": 0
+ },
+ {
+ "state_name": "fanAfail",
+ "state_descr": "OK",
+ "state_draw_graph": 0,
+ "state_value": 0,
+ "state_generic_value": 0
+ },
+ {
+ "state_name": "fanAfail",
+ "state_descr": "FAIL",
+ "state_draw_graph": 0,
+ "state_value": 1,
+ "state_generic_value": 2
+ },
+ {
+ "state_name": "fanBfail",
+ "state_descr": "OK",
+ "state_draw_graph": 0,
+ "state_value": 0,
+ "state_generic_value": 0
+ },
+ {
+ "state_name": "fanBfail",
+ "state_descr": "FAIL",
+ "state_draw_graph": 0,
+ "state_value": 1,
+ "state_generic_value": 2
+ },
+ {
+ "state_name": "overheat",
+ "state_descr": "OK",
+ "state_draw_graph": 1,
+ "state_value": 0,
+ "state_generic_value": 0
+ },
+ {
+ "state_name": "overheat",
+ "state_descr": "OVERHEAT",
+ "state_draw_graph": 1,
+ "state_value": 1,
+ "state_generic_value": 2
+ },
+ {
+ "state_name": "overload",
+ "state_descr": "OK",
+ "state_draw_graph": 1,
+ "state_value": 0,
+ "state_generic_value": 0
+ },
+ {
+ "state_name": "overload",
+ "state_descr": "OVERLOAD",
+ "state_draw_graph": 1,
+ "state_value": 1,
+ "state_generic_value": 2
+ }
+ ]
+ },
+ "poller": "matches discovery"
+ }
+}
diff --git a/tests/snmpsim/algcom-dc-ups.snmprec b/tests/snmpsim/algcom-dc-ups.snmprec
new file mode 100644
index 0000000000..879933d2f1
--- /dev/null
+++ b/tests/snmpsim/algcom-dc-ups.snmprec
@@ -0,0 +1,28 @@
+1.3.6.1.2.1.1.1.0|4|DC UPS ALGCOM
+1.3.6.1.2.1.1.2.0|6|1.3.6.1.4.1.49136
+1.3.6.1.2.1.1.3.0|67|95160934
+1.3.6.1.2.1.1.4.0|4|
+1.3.6.1.2.1.1.5.0|4|
+1.3.6.1.2.1.1.6.0|4|
+1.3.6.1.4.1.49136.1.1.1.0|2|539
+1.3.6.1.4.1.49136.1.1.2.0|2|1374
+1.3.6.1.4.1.49136.1.2.1.0|2|539
+1.3.6.1.4.1.49136.1.2.2.0|2|0
+1.3.6.1.4.1.49136.1.2.3.0|2|5
+1.3.6.1.4.1.49136.1.3.1.0|2|0
+1.3.6.1.4.1.49136.1.3.2.0|2|0
+1.3.6.1.4.1.49136.1.3.3.0|2|1
+1.3.6.1.4.1.49136.1.3.4.0|2|0
+1.3.6.1.4.1.49136.1.3.5.0|2|0
+1.3.6.1.4.1.49136.1.3.6.0|2|0
+1.3.6.1.4.1.49136.1.3.7.0|2|0
+1.3.6.1.4.1.49136.1.3.8.0|2|0
+1.3.6.1.4.1.49136.1.3.11.0|2|264
+1.3.6.1.4.1.49136.1.4.1.0|2|37
+1.3.6.1.4.1.49136.1.4.2.0|2|0
+1.3.6.1.4.1.49136.1.4.3.0|2|28
+1.3.6.1.4.1.49136.1.6.1.0|2|0
+1.3.6.1.4.1.49136.1.8.5.0|2|517
+1.3.6.1.4.1.49136.1.8.6.0|2|-1581
+1.3.6.1.4.1.49136.1.8.7.0|2|419
+1.3.6.1.4.1.49136.1.8.8.0|2|-1897