mirror of
https://github.com/librenms/librenms.git
synced 2024-10-07 16:52:45 +00:00
updates and new MIB
git-svn-id: http://www.observium.org/svn/observer/trunk@399 61d68cd4-352d-0410-923a-c4978735b2b8
This commit is contained in:
@@ -1,3 +1,5 @@
|
||||
Changed IPv6 database structure and discovery *** DATABASE CHANGE ***
|
||||
|
||||
Release 0.5.1 ( 25 March 2009 )
|
||||
|
||||
Primarily bugfixes to 0.5.0
|
||||
|
@@ -1,5 +1,6 @@
|
||||
<?php
|
||||
|
||||
@ini_set("session.gc_maxlifetime","10000");
|
||||
session_start();
|
||||
|
||||
if($_GET['logout']) {
|
||||
|
@@ -18,7 +18,7 @@
|
||||
$ifType = fixiftype($interface['ifType']);
|
||||
$ifHardType = $interface['ifHardType'];
|
||||
|
||||
if($ifAlias) {$ifAlias = $ifAlias . "</br>";}
|
||||
# if($ifAlias) {$ifAlias = $ifAlias . ;}
|
||||
#if($bg == "#ffffff") { $bg = "#e5e5e5"; } else { $bg="#ffffff"; }
|
||||
if($bg == "#e5e5e5") { $bg = "#ffffff"; } else { $bg="#e5e5e5"; }
|
||||
|
||||
@@ -36,7 +36,7 @@
|
||||
|
||||
</span><br /><span class=interface-desc>$ifAlias</span>");
|
||||
|
||||
# if($ifAlias) { echo("<br />"); }
|
||||
if($ifAlias) { echo("<br />"); }
|
||||
|
||||
unset ($break);
|
||||
if(!$dographs) {
|
||||
@@ -47,7 +47,7 @@
|
||||
}
|
||||
$ip6data = mysql_query("SELECT * FROM `ip6addr` WHERE `interface_id` = '" . $interface['interface_id'] . "'");
|
||||
while($ip6 = mysql_fetch_Array($ip6data)) {
|
||||
echo("$break <a class=interface-desc href=\"javascript:popUp('/netcmd.php?cmd=whois&query=$ip6[addr]')\">".Net_IPv6::compress($ip6[addr])."/$ip6[cidr]</a>");
|
||||
echo("$break <a class=interface-desc href=\"javascript:popUp('/netcmd.php?cmd=whois&query=".$ip6['ip6_addr']."')\">".Net_IPv6::compress($ip6['ip6_addr'])."/".$ip6['ip6_prefixlen']."</a>");
|
||||
$break = "<br />";
|
||||
}
|
||||
|
||||
@@ -143,25 +143,23 @@ echo("</td>");
|
||||
unset($br);
|
||||
# }
|
||||
|
||||
$sql = "SELECT network_id FROM ip6addr AS A, ip6networks AS N, interfaces AS I
|
||||
WHERE A.interface_id = I.interface_id
|
||||
AND A.network = N.cidr
|
||||
AND I.interface_id = '".$interface['interface_id']."'";
|
||||
$sql = "SELECT ip6_network_id FROM ip6addr WHERE interface_id = '".$interface['interface_id']."'";
|
||||
|
||||
$nets_query = mysql_query($sql);
|
||||
|
||||
while($net = mysql_fetch_array($nets_query)) {
|
||||
$network_id = $net['network_id'];
|
||||
echo($net['ip6_network']);
|
||||
$ip6_network_id = $net['ip6_network_id'];
|
||||
|
||||
$sql = "SELECT I.interface_id FROM ip6addr AS A, ip6networks AS N, interfaces AS I, devices AS D
|
||||
WHERE A.interface_id = I.interface_id
|
||||
AND A.network = N.cidr AND N.network_id = '".$net['network_id']."' AND D.device_id = I.device_id
|
||||
AND D.device_id != '".$device['device_id']."' AND A.origin != 'linklayer' AND A.origin != 'wellknown'";
|
||||
AND A.ip6_network = N.ip6_network AND N.ip6_network_id = '".$net['ip6_network_id']."' AND D.device_id = I.device_id
|
||||
AND D.device_id != '".$device['device_id']."' AND A.ip6_origin != 'linklayer' AND A.ip6_origin != 'wellknown'";
|
||||
|
||||
$new_query = mysql_query($sql);
|
||||
while($new = mysql_fetch_array($new_query)) {
|
||||
|
||||
echo($new['network_id']);
|
||||
echo($new['ip6_network_id']);
|
||||
|
||||
$this_ifid = $new['interface_id'];
|
||||
$this_hostid = $new['device_id'];
|
||||
|
@@ -1,6 +1,6 @@
|
||||
<?php
|
||||
echo("
|
||||
<div style='float: right; text-align: right; padding-bottom: 10px'>
|
||||
<div style='width: 100%; text-align: right; padding-bottom: 10px; clear: both; display:block; height:20px;'>
|
||||
<a href='".$config['base_url']."/device/" . $device['device_id'] . "/ports/'>Details</a> | Graphs:
|
||||
<a href='".$config['base_url']."/device/" . $device['device_id'] . "/ports/graphs/bits/'>Bits</a> |
|
||||
<a href='".$config['base_url']."/device/" . $device['device_id'] . "/ports/graphs/pkts/'>Packets</a> |
|
||||
@@ -21,7 +21,7 @@ $hostname = gethostbyid($device['device_id']);
|
||||
|
||||
echo("<div style='margin: 5px;'><table border=0 cellspacing=0 cellpadding=5 width=100%>");
|
||||
$i = "1";
|
||||
$interface_query = mysql_query("select * from interfaces WHERE device_id = '$_GET[id]' AND deleted = '0' ORDER BY `ifDescr` ASC");
|
||||
$interface_query = mysql_query("select * from interfaces WHERE device_id = '$_GET[id]' AND deleted = '0' ORDER BY `ifIndex` ASC");
|
||||
while($interface = mysql_fetch_array($interface_query)) {
|
||||
include("includes/print-interface.inc");
|
||||
}
|
||||
|
@@ -7,7 +7,6 @@ $ipv6interfaces = shell_exec($config['snmpget']." -Ovnq -".$device['snmpver']."
|
||||
if($ipv6interfaces){
|
||||
|
||||
$oids = trim(trim(shell_exec($config['snmpwalk']." -".$device['snmpver']." -Ln -c ".$device['community']." ".$device['hostname'].":".$device['port']." ipAddressIfIndex.ipv6 -Osq | grep -v No")));
|
||||
echo($config['snmpwalk']." -".$device['snmpver']." -Ln -c ".$device['community']." ".$device['hostname'].":".$device['port']." ipAddressIfIndex.ipv6 -Osq | grep -v No");
|
||||
$oids = str_replace("ipAddressIfIndex.ipv6.", "", $oids); $oids = str_replace("\"", "", $oids); $oids = trim($oids);
|
||||
foreach(explode("\n", $oids) as $data) {
|
||||
if($data) {
|
||||
@@ -15,43 +14,64 @@ if($ipv6interfaces){
|
||||
list($ipv6addr,$ifIndex) = explode(" ", $data);
|
||||
$oid = "";
|
||||
$sep = ''; $adsep = '';
|
||||
unset($address);
|
||||
unset($ip6_addr);
|
||||
$do = '0';
|
||||
foreach(explode(":", $ipv6addr) as $part) {
|
||||
$n = hexdec($part);
|
||||
$oid = "$oid" . "$sep" . "$n";
|
||||
$sep = ".";
|
||||
$address = $address . "$adsep" . $part;
|
||||
$ip6_addr = $ip6_addr . "$adsep" . $part;
|
||||
$do++;
|
||||
if($do == 2) { $adsep = ":"; $do = '0'; } else { $adsep = "";}
|
||||
}
|
||||
$ip6_prefixlen = trim(shell_exec($config['snmpget']." -".$device['snmpver']." -c ".$device['community']." ".$device['hostname'].":".$device['port']." .1.3.6.1.2.1.4.34.1.5.2.16.$oid | sed 's/.*\.//'"));
|
||||
$ip6_origin = trim(shell_exec($config['snmpget']." -Ovq -".$device['snmpver']." -c ".$device['community']." ".$device['hostname'].":".$device['port']." .1.3.6.1.2.1.4.34.1.6.2.16.$oid"));
|
||||
|
||||
$cidr = trim(shell_exec($config['snmpget']." -".$device['snmpver']." -c ".$device['community']." ".$device['hostname'].":".$device['port']." .1.3.6.1.2.1.4.34.1.5.2.16.$oid | sed 's/.*\.//'"));
|
||||
$origin = trim(shell_exec($config['snmpget']." -Ovq -".$device['snmpver']." -c ".$device['community']." ".$device['hostname'].":".$device['port']." .1.3.6.1.2.1.4.34.1.6.2.16.$oid"));
|
||||
$ip6_network = trim(shell_exec($config['sipcalc']." $ip6_addr/$ip6_prefixlen | grep Subnet | cut -f 2 -d '-'"));
|
||||
$ip6_comp_addr = trim(shell_exec($config['sipcalc']." $ip6_addr/$ip6_prefixlen | grep Compressed | cut -f 2 -d '-'"));
|
||||
|
||||
$network = trim(shell_exec($config['sipcalc']." $address/$cidr | grep Subnet | cut -f 2 -d '-'"));
|
||||
$comp = trim(shell_exec($config['sipcalc']." $address/$cidr | grep Compressed | cut -f 2 -d '-'"));
|
||||
|
||||
if (mysql_result(mysql_query("SELECT count(*) FROM `interfaces` WHERE device_id = '".$device['device_id']."' AND `ifIndex` = '$ifIndex'"), 0) != '0' && $cidr > '0' && $cidr < '129' && $comp != '::1') {
|
||||
if (mysql_result(mysql_query("SELECT count(*) FROM `interfaces` WHERE device_id = '".$device['device_id']."' AND `ifIndex` = '$ifIndex'"), 0) != '0' && $ip6_prefixlen > '0' && $ip6_prefixlen < '129' && $ip6_comp_addr != '::1') {
|
||||
$i_query = "SELECT interface_id FROM `interfaces` WHERE device_id = '".$device['device_id']."' AND `ifIndex` = '$ifIndex'";
|
||||
$interface_id = mysql_result(mysql_query($i_query), 0);
|
||||
if (mysql_result(mysql_query("SELECT COUNT(*) FROM `ip6addr` WHERE `addr` = '$address' AND `cidr` = '$cidr' AND `interface_id` = '$interface_id'"), 0) == '0') {
|
||||
mysql_query("INSERT INTO `ip6addr` (`addr`, `comp_addr`, `cidr`, `origin`, `network`, `interface_id`) VALUES ('$address', '$comp', '$cidr', '$origin', '$network', '$interface_id')");
|
||||
echo("+");
|
||||
} else { echo("."); }
|
||||
if (mysql_result(mysql_query("SELECT COUNT(*) FROM `ip6networks` WHERE `cidr` = '$network'"), 0) < '1') {
|
||||
mysql_query("INSERT INTO `ip6networks` (`id`, `cidr`) VALUES ('', '$network')");
|
||||
if (mysql_result(mysql_query("SELECT COUNT(*) FROM `ip6networks` WHERE `ip6_network` = '$ip6_network'"), 0) < '1') {
|
||||
mysql_query("INSERT INTO `ip6networks` (`ip6_network`) VALUES ('$ip6_network')");
|
||||
echo("N");
|
||||
}
|
||||
$network_id = @mysql_result(mysql_query("SELECT id from `ip6networks` WHERE `cidr` = '$network'"), 0);
|
||||
if (match_network($nets, $address) && mysql_result(mysql_query("SELECT COUNT(*) FROM `ip6adjacencies` WHERE `network_id` = '$network_id' AND `interface_id` = '$interface_id'"), 0) < '1') {
|
||||
mysql_query("INSERT INTO `ip6adjacencies` (`network_id`, `interface_id`) VALUES ('$network_id', '$interface_id')");
|
||||
echo("A");
|
||||
|
||||
if (mysql_result(mysql_query("SELECT COUNT(*) FROM `ip6networks` WHERE `ip6_network` = '$ip6_network'"), 0) < '1') {
|
||||
mysql_query("INSERT INTO `ip6networks` (`ip6_network`) VALUES ('$ip6_network')");
|
||||
echo("N");
|
||||
}
|
||||
$ip6_network_id = @mysql_result(mysql_query("SELECT `ip6_network_id` from `ip6networks` WHERE `ip6_network` = '$ip6_network'"), 0);
|
||||
|
||||
if (mysql_result(mysql_query("SELECT COUNT(*) FROM `ip6addr` WHERE `ip6_addr` = '$ip6_addr' AND `ip6_prefixlen` = '$ip6_prefixlen' AND `interface_id` = '$interface_id'"), 0) == '0') {
|
||||
mysql_query("INSERT INTO `ip6addr` (`ip6_addr`, `ip6_comp_addr`, `ip6_prefixlen`, `ip6_origin`, `ip6_network`, `ip6_network_id`, `interface_id`) VALUES ('$ip6_addr', '$ip6_comp_addr', '$ip6_prefixlen', '$ip6_origin', '$ip6_network', '$ip6_network_id', '$interface_id')");
|
||||
echo("+");
|
||||
} else { echo("."); }
|
||||
# if (mysql_result(mysql_query("SELECT COUNT(*) FROM `ip6adjacencies` WHERE `ip6_network_id` = '$ip6_network_id' AND `interface_id` = '$interface_id'"), 0) < '1') {
|
||||
# mysql_query("INSERT INTO `ip6adjacencies` (`network_id`, `interface_id`) VALUES ('$ip6_network_id', '$interface_id')");
|
||||
# echo("A");
|
||||
# }
|
||||
$full_address = "$ip6_addr/$ip6_prefixlen";
|
||||
$valid_v6[$full_address] = 1;
|
||||
}
|
||||
}
|
||||
}
|
||||
} else { echo("None configured"); }
|
||||
|
||||
$sql = "SELECT * FROM ip6addr AS A, interfaces AS I WHERE I.device_id = '".$device['device_id']."' AND A.interface_id = I.interface_id";
|
||||
$data = mysql_query($sql);
|
||||
while($row = mysql_fetch_array($data)) {
|
||||
$full_address = $row['ip6_addr'] . "/" . $row['ip6_prefixlen'];
|
||||
if(!$valid_v6[$full_address]) {
|
||||
echo("-");
|
||||
$query = @mysql_query("DELETE FROM `ip6addr` WHERE `ip6_addr_id` = '".$row['ip6_addr_id']."'");
|
||||
if(!mysql_result(mysql_query("SELECT count(*) FROM ip6addr WHERE ip6_network_id = '".$row['ip6_network_id']."'"),0)) {
|
||||
$query = @mysql_query("DELETE FROM `ip6networks` WHERE `ip6_network_id` = '".$row['ip6_network_id']."'");
|
||||
}
|
||||
}
|
||||
}
|
||||
unset($valid_v6);
|
||||
|
||||
?>
|
||||
|
||||
|
932
mibs/CISCO-ENVMON-MIB.my
Normal file
932
mibs/CISCO-ENVMON-MIB.my
Normal file
@@ -0,0 +1,932 @@
|
||||
-- *****************************************************************
|
||||
-- CISCO-ENVMON-MIB.my: CISCO Environmental Monitor MIB file
|
||||
--
|
||||
-- November 1994 Sandra C. Durham/Jeffrey T. Johnson
|
||||
--
|
||||
-- Copyright (c) 1994-2001, 2002 by cisco Systems, Inc.
|
||||
-- All rights reserved.
|
||||
--
|
||||
-- *****************************************************************
|
||||
--
|
||||
CISCO-ENVMON-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE,
|
||||
NOTIFICATION-TYPE,
|
||||
Gauge32,
|
||||
Integer32
|
||||
FROM SNMPv2-SMI
|
||||
TEXTUAL-CONVENTION,
|
||||
DisplayString,
|
||||
TruthValue
|
||||
FROM SNMPv2-TC
|
||||
MODULE-COMPLIANCE,
|
||||
OBJECT-GROUP,
|
||||
NOTIFICATION-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
ciscoMgmt
|
||||
FROM CISCO-SMI;
|
||||
|
||||
|
||||
ciscoEnvMonMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "200311250000Z"
|
||||
ORGANIZATION "Cisco Systems, Inc."
|
||||
CONTACT-INFO
|
||||
" Cisco Systems
|
||||
Customer Service
|
||||
|
||||
Postal: 170 W Tasman Drive
|
||||
San Jose, CA 95134
|
||||
USA
|
||||
|
||||
Tel: +1 800 553-NETS
|
||||
|
||||
E-mail: cs-snmp@cisco.com"
|
||||
DESCRIPTION
|
||||
"The MIB module to describe the status of the Environmental
|
||||
Monitor on those devices which support one."
|
||||
REVISION "200311250000Z"
|
||||
DESCRIPTION
|
||||
"Added ciscoEnvMonMIBMiscNotifGroup."
|
||||
REVISION "200210150000Z"
|
||||
DESCRIPTION
|
||||
"Added c7600(12) as values for ciscoEnvMonPresent"
|
||||
REVISION "200207170000Z"
|
||||
DESCRIPTION
|
||||
"Added optional groups ciscoEnvMonEnableStatChangeGroup
|
||||
and ciscoEnvMonStatChangeNotifGroup."
|
||||
REVISION "200202040000Z"
|
||||
DESCRIPTION
|
||||
"Added osr7600(11) as values
|
||||
for ciscoEnvMonPresent"
|
||||
REVISION "200108300000Z"
|
||||
DESCRIPTION
|
||||
"Added c10000(10) as values for ciscoEnvMonPresent"
|
||||
REVISION "200108160000Z"
|
||||
DESCRIPTION
|
||||
"Added cat4000(9) as values for ciscoEnvMonPresent"
|
||||
REVISION "200105070000Z"
|
||||
DESCRIPTION
|
||||
"Added cat6000(7),ubr7200(8)
|
||||
as values for ciscoEnvMonPresent"
|
||||
REVISION "200001310000Z"
|
||||
DESCRIPTION
|
||||
"Add notFunctioning to CiscoEnvMonState.
|
||||
"
|
||||
REVISION "9810220000Z"
|
||||
DESCRIPTION
|
||||
"Renamed enumerated value internalRPS(5) as
|
||||
internalRedundant(5) and added description for
|
||||
ciscoEnvMonSupplySource enumerated values.
|
||||
"
|
||||
REVISION "9808050000Z"
|
||||
DESCRIPTION
|
||||
"Add enumerated value internalRPS(5) to
|
||||
ciscoEnvMonSupplySource.
|
||||
"
|
||||
REVISION "9611120000Z"
|
||||
DESCRIPTION
|
||||
"Add monitoring support for c3600 series router"
|
||||
REVISION "9508150000Z"
|
||||
DESCRIPTION
|
||||
"Specify a correct (non-negative) range for several
|
||||
index objects."
|
||||
REVISION "9503130000Z"
|
||||
DESCRIPTION
|
||||
"Miscellaneous changes including monitoring support
|
||||
for c7000 series redundant power supplies."
|
||||
|
||||
::= { ciscoMgmt 13 }
|
||||
|
||||
|
||||
CiscoEnvMonState ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Represents the state of a device being monitored.
|
||||
Valid values are:
|
||||
|
||||
normal(1): the environment is good, such as low
|
||||
temperature.
|
||||
|
||||
warning(2): the environment is bad, such as temperature
|
||||
above normal operation range but not too
|
||||
high.
|
||||
|
||||
critical(3): the environment is very bad, such as
|
||||
temperature much higher than normal
|
||||
operation limit.
|
||||
|
||||
shutdown(4): the environment is the worst, the system
|
||||
should be shutdown immediately.
|
||||
|
||||
notPresent(5): the environmental monitor is not present,
|
||||
such as temperature sensors do not exist.
|
||||
|
||||
notFunctioning(6): the environmental monitor does not
|
||||
function properly, such as a temperature
|
||||
sensor generates a abnormal data like
|
||||
1000 C.
|
||||
"
|
||||
SYNTAX INTEGER {
|
||||
normal(1),
|
||||
warning(2),
|
||||
critical(3),
|
||||
shutdown(4),
|
||||
notPresent(5),
|
||||
notFunctioning(6)
|
||||
}
|
||||
|
||||
CiscoSignedGauge ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Represents the current value of an entity, as a signed
|
||||
integer."
|
||||
SYNTAX Integer32
|
||||
|
||||
ciscoEnvMonObjects OBJECT IDENTIFIER ::= { ciscoEnvMonMIB 1 }
|
||||
|
||||
ciscoEnvMonPresent OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
oldAgs (1),
|
||||
ags (2),
|
||||
c7000 (3),
|
||||
ci (4),
|
||||
cAccessMon (6),
|
||||
cat6000 (7),
|
||||
ubr7200 (8),
|
||||
cat4000 (9),
|
||||
c10000 (10),
|
||||
osr7600(11),
|
||||
c7600 (12)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The type of environmental monitor located in the chassis.
|
||||
An oldAgs environmental monitor card is identical to an ags
|
||||
environmental card except that it is not capable of supplying
|
||||
data, and hence no instance of the remaining objects in this
|
||||
MIB will be returned in response to an SNMP query. Note that
|
||||
only a firmware upgrade is required to convert an oldAgs into
|
||||
an ags card."
|
||||
::= { ciscoEnvMonObjects 1 }
|
||||
|
||||
|
||||
ciscoEnvMonVoltageStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF CiscoEnvMonVoltageStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table of voltage status maintained by the environmental
|
||||
monitor."
|
||||
::= { ciscoEnvMonObjects 2 }
|
||||
|
||||
ciscoEnvMonVoltageStatusEntry OBJECT-TYPE
|
||||
SYNTAX CiscoEnvMonVoltageStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the voltage status table, representing the status
|
||||
of the associated testpoint maintained by the environmental
|
||||
monitor."
|
||||
INDEX { ciscoEnvMonVoltageStatusIndex }
|
||||
::= { ciscoEnvMonVoltageStatusTable 1 }
|
||||
|
||||
CiscoEnvMonVoltageStatusEntry ::=
|
||||
SEQUENCE {
|
||||
ciscoEnvMonVoltageStatusIndex Integer32 (0..2147483647),
|
||||
ciscoEnvMonVoltageStatusDescr DisplayString,
|
||||
ciscoEnvMonVoltageStatusValue CiscoSignedGauge,
|
||||
ciscoEnvMonVoltageThresholdLow Integer32,
|
||||
ciscoEnvMonVoltageThresholdHigh Integer32,
|
||||
ciscoEnvMonVoltageLastShutdown Integer32,
|
||||
ciscoEnvMonVoltageState CiscoEnvMonState
|
||||
}
|
||||
|
||||
ciscoEnvMonVoltageStatusIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique index for the testpoint being instrumented.
|
||||
This index is for SNMP purposes only, and has no
|
||||
intrinsic meaning."
|
||||
::= { ciscoEnvMonVoltageStatusEntry 1 }
|
||||
|
||||
ciscoEnvMonVoltageStatusDescr OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Textual description of the testpoint being instrumented.
|
||||
This description is a short textual label, suitable as a
|
||||
human-sensible identification for the rest of the
|
||||
information in the entry."
|
||||
::= { ciscoEnvMonVoltageStatusEntry 2 }
|
||||
|
||||
ciscoEnvMonVoltageStatusValue OBJECT-TYPE
|
||||
SYNTAX CiscoSignedGauge
|
||||
UNITS "millivolts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current measurement of the testpoint being instrumented."
|
||||
::= { ciscoEnvMonVoltageStatusEntry 3 }
|
||||
|
||||
ciscoEnvMonVoltageThresholdLow OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "millivolts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The lowest value that the associated instance of the object
|
||||
ciscoEnvMonVoltageStatusValue may obtain before an emergency
|
||||
shutdown of the managed device is initiated."
|
||||
::= { ciscoEnvMonVoltageStatusEntry 4 }
|
||||
|
||||
ciscoEnvMonVoltageThresholdHigh OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "millivolts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The highest value that the associated instance of the object
|
||||
ciscoEnvMonVoltageStatusValue may obtain before an emergency
|
||||
shutdown of the managed device is initiated."
|
||||
::= { ciscoEnvMonVoltageStatusEntry 5 }
|
||||
|
||||
ciscoEnvMonVoltageLastShutdown OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "millivolts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of the associated instance of the object
|
||||
ciscoEnvMonVoltageStatusValue at the time an emergency
|
||||
shutdown of the managed device was last initiated. This
|
||||
value is stored in non-volatile RAM and hence is able to
|
||||
survive the shutdown."
|
||||
::= { ciscoEnvMonVoltageStatusEntry 6 }
|
||||
|
||||
ciscoEnvMonVoltageState OBJECT-TYPE
|
||||
SYNTAX CiscoEnvMonState
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current state of the testpoint being instrumented."
|
||||
::= { ciscoEnvMonVoltageStatusEntry 7 }
|
||||
|
||||
|
||||
|
||||
ciscoEnvMonTemperatureStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF CiscoEnvMonTemperatureStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table of ambient temperature status maintained by the
|
||||
environmental monitor."
|
||||
::= { ciscoEnvMonObjects 3 }
|
||||
|
||||
ciscoEnvMonTemperatureStatusEntry OBJECT-TYPE
|
||||
SYNTAX CiscoEnvMonTemperatureStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the ambient temperature status table, representing
|
||||
the status of the associated testpoint maintained by the
|
||||
environmental monitor."
|
||||
INDEX { ciscoEnvMonTemperatureStatusIndex }
|
||||
::= { ciscoEnvMonTemperatureStatusTable 1 }
|
||||
|
||||
CiscoEnvMonTemperatureStatusEntry ::=
|
||||
SEQUENCE {
|
||||
ciscoEnvMonTemperatureStatusIndex Integer32 (0..2147483647),
|
||||
ciscoEnvMonTemperatureStatusDescr DisplayString,
|
||||
ciscoEnvMonTemperatureStatusValue Gauge32,
|
||||
ciscoEnvMonTemperatureThreshold Integer32,
|
||||
ciscoEnvMonTemperatureLastShutdown Integer32,
|
||||
ciscoEnvMonTemperatureState CiscoEnvMonState
|
||||
}
|
||||
|
||||
|
||||
ciscoEnvMonTemperatureStatusIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique index for the testpoint being instrumented.
|
||||
This index is for SNMP purposes only, and has no
|
||||
intrinsic meaning."
|
||||
::= { ciscoEnvMonTemperatureStatusEntry 1 }
|
||||
|
||||
ciscoEnvMonTemperatureStatusDescr OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Textual description of the testpoint being instrumented.
|
||||
This description is a short textual label, suitable as a
|
||||
human-sensible identification for the rest of the
|
||||
information in the entry."
|
||||
::= { ciscoEnvMonTemperatureStatusEntry 2 }
|
||||
|
||||
ciscoEnvMonTemperatureStatusValue OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
UNITS "degrees Celsius"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current measurement of the testpoint being instrumented."
|
||||
::= { ciscoEnvMonTemperatureStatusEntry 3 }
|
||||
|
||||
ciscoEnvMonTemperatureThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "degrees Celsius"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The highest value that the associated instance of the
|
||||
object ciscoEnvMonTemperatureStatusValue may obtain
|
||||
before an emergency shutdown of the managed device is
|
||||
initiated."
|
||||
::= { ciscoEnvMonTemperatureStatusEntry 4 }
|
||||
|
||||
ciscoEnvMonTemperatureLastShutdown OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "degrees Celsius"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of the associated instance of the object
|
||||
ciscoEnvMonTemperatureStatusValue at the time an emergency
|
||||
shutdown of the managed device was last initiated. This
|
||||
value is stored in non-volatile RAM and hence is able to
|
||||
survive the shutdown."
|
||||
::= { ciscoEnvMonTemperatureStatusEntry 5 }
|
||||
|
||||
ciscoEnvMonTemperatureState OBJECT-TYPE
|
||||
SYNTAX CiscoEnvMonState
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current state of the testpoint being instrumented."
|
||||
::= { ciscoEnvMonTemperatureStatusEntry 6 }
|
||||
|
||||
|
||||
|
||||
ciscoEnvMonFanStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF CiscoEnvMonFanStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table of fan status maintained by the environmental
|
||||
monitor."
|
||||
::= { ciscoEnvMonObjects 4 }
|
||||
|
||||
ciscoEnvMonFanStatusEntry OBJECT-TYPE
|
||||
SYNTAX CiscoEnvMonFanStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the fan status table, representing the status of
|
||||
the associated fan maintained by the environmental monitor."
|
||||
INDEX { ciscoEnvMonFanStatusIndex }
|
||||
::= { ciscoEnvMonFanStatusTable 1 }
|
||||
|
||||
CiscoEnvMonFanStatusEntry ::=
|
||||
SEQUENCE {
|
||||
ciscoEnvMonFanStatusIndex Integer32 (0..2147483647),
|
||||
ciscoEnvMonFanStatusDescr DisplayString,
|
||||
ciscoEnvMonFanState CiscoEnvMonState
|
||||
}
|
||||
|
||||
ciscoEnvMonFanStatusIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique index for the fan being instrumented.
|
||||
This index is for SNMP purposes only, and has no
|
||||
intrinsic meaning."
|
||||
::= { ciscoEnvMonFanStatusEntry 1 }
|
||||
|
||||
ciscoEnvMonFanStatusDescr OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Textual description of the fan being instrumented.
|
||||
This description is a short textual label, suitable as a
|
||||
human-sensible identification for the rest of the
|
||||
information in the entry."
|
||||
::= { ciscoEnvMonFanStatusEntry 2 }
|
||||
|
||||
ciscoEnvMonFanState OBJECT-TYPE
|
||||
SYNTAX CiscoEnvMonState
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current state of the fan being instrumented."
|
||||
::= { ciscoEnvMonFanStatusEntry 3 }
|
||||
|
||||
|
||||
|
||||
ciscoEnvMonSupplyStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF CiscoEnvMonSupplyStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table of power supply status maintained by the
|
||||
environmental monitor card."
|
||||
::= { ciscoEnvMonObjects 5 }
|
||||
|
||||
ciscoEnvMonSupplyStatusEntry OBJECT-TYPE
|
||||
SYNTAX CiscoEnvMonSupplyStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the power supply status table, representing the
|
||||
status of the associated power supply maintained by the
|
||||
environmental monitor card."
|
||||
INDEX { ciscoEnvMonSupplyStatusIndex }
|
||||
::= { ciscoEnvMonSupplyStatusTable 1 }
|
||||
|
||||
CiscoEnvMonSupplyStatusEntry ::=
|
||||
SEQUENCE {
|
||||
ciscoEnvMonSupplyStatusIndex Integer32 (0..2147483647),
|
||||
ciscoEnvMonSupplyStatusDescr DisplayString,
|
||||
ciscoEnvMonSupplyState CiscoEnvMonState,
|
||||
ciscoEnvMonSupplySource INTEGER
|
||||
}
|
||||
|
||||
ciscoEnvMonSupplyStatusIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique index for the power supply being instrumented.
|
||||
This index is for SNMP purposes only, and has no
|
||||
intrinsic meaning."
|
||||
::= { ciscoEnvMonSupplyStatusEntry 1 }
|
||||
|
||||
ciscoEnvMonSupplyStatusDescr OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Textual description of the power supply being instrumented.
|
||||
This description is a short textual label, suitable as a
|
||||
human-sensible identification for the rest of the
|
||||
information in the entry."
|
||||
::= { ciscoEnvMonSupplyStatusEntry 2 }
|
||||
|
||||
ciscoEnvMonSupplyState OBJECT-TYPE
|
||||
SYNTAX CiscoEnvMonState
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current state of the power supply being instrumented."
|
||||
::= { ciscoEnvMonSupplyStatusEntry 3 }
|
||||
|
||||
ciscoEnvMonSupplySource OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
unknown(1),
|
||||
ac(2),
|
||||
dc(3),
|
||||
externalPowerSupply(4),
|
||||
internalRedundant(5)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The power supply source.
|
||||
unknown - Power supply source unknown
|
||||
ac - AC power supply
|
||||
dc - DC power supply
|
||||
externalPowerSupply - External power supply
|
||||
internalRedundant - Internal redundant power supply
|
||||
"
|
||||
::= { ciscoEnvMonSupplyStatusEntry 4 }
|
||||
|
||||
ciscoEnvMonAlarmContacts OBJECT-TYPE
|
||||
SYNTAX BITS {
|
||||
minorVisual(0),
|
||||
majorVisual(1),
|
||||
criticalVisual(2),
|
||||
minorAudible(3),
|
||||
majorAudible(4),
|
||||
criticalAudible(5),
|
||||
input(6)
|
||||
}
|
||||
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Each bit is set to reflect the respective
|
||||
alarm being set. The bit will be cleared
|
||||
when the respective alarm is cleared."
|
||||
::= { ciscoEnvMonObjects 6 }
|
||||
|
||||
ciscoEnvMonMIBNotificationEnables OBJECT IDENTIFIER ::= { ciscoEnvMonMIB 2 }
|
||||
|
||||
ciscoEnvMonEnableShutdownNotification OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates whether the system
|
||||
produces the ciscoEnvMonShutdownNotification. A false
|
||||
value will prevent shutdown notifications
|
||||
from being generated by this system."
|
||||
DEFVAL { false }
|
||||
::= { ciscoEnvMonMIBNotificationEnables 1 }
|
||||
|
||||
ciscoEnvMonEnableVoltageNotification OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"This variable indicates whether the system
|
||||
produces the ciscoEnvMonVoltageNotification. A false
|
||||
value will prevent voltage notifications from being
|
||||
generated by this system. This object is deprecated
|
||||
in favour of ciscoEnvMonEnableStatChangeNotif."
|
||||
DEFVAL { false }
|
||||
::= { ciscoEnvMonMIBNotificationEnables 2 }
|
||||
|
||||
ciscoEnvMonEnableTemperatureNotification OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"This variable indicates whether the system
|
||||
produces the ciscoEnvMonTemperatureNotification.
|
||||
A false value prevents temperature notifications
|
||||
from being sent by this entity. This object is
|
||||
deprecated in favour of
|
||||
ciscoEnvMonEnableStatChangeNotif."
|
||||
DEFVAL { false }
|
||||
::= { ciscoEnvMonMIBNotificationEnables 3 }
|
||||
|
||||
ciscoEnvMonEnableFanNotification OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"This variable indicates whether the system
|
||||
produces the ciscoEnvMonFanNotification.
|
||||
A false value prevents fan notifications
|
||||
from being sent by this entity. This object is
|
||||
deprecated in favour of
|
||||
ciscoEnvMonEnableStatChangeNotif."
|
||||
DEFVAL { false }
|
||||
::= { ciscoEnvMonMIBNotificationEnables 4 }
|
||||
|
||||
ciscoEnvMonEnableRedundantSupplyNotification OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"This variable indicates whether the system
|
||||
produces the ciscoEnvMonRedundantSupplyNotification.
|
||||
A false value prevents redundant supply notifications
|
||||
from being generated by this system. This object is
|
||||
deprecated in favour of
|
||||
ciscoEnvMonEnableStatChangeNotif."
|
||||
DEFVAL { false }
|
||||
::= { ciscoEnvMonMIBNotificationEnables 5 }
|
||||
|
||||
ciscoEnvMonEnableStatChangeNotif OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates whether the system
|
||||
produces the ciscoEnvMonVoltStatusChangeNotif,
|
||||
ciscoEnvMonTempStatusChangeNotif,
|
||||
ciscoEnvMonFanStatusChangeNotif and
|
||||
ciscoEnvMonSuppStatusChangeNotif. A false value will
|
||||
prevent these notifications from being generated by
|
||||
this system."
|
||||
DEFVAL { false }
|
||||
::= { ciscoEnvMonMIBNotificationEnables 6 }
|
||||
|
||||
-- the following two OBJECT IDENTIFIERS are used to define SNMPv2 Notifications
|
||||
-- that are backward compatible with SNMPv1 Traps.
|
||||
ciscoEnvMonMIBNotificationPrefix OBJECT IDENTIFIER ::= { ciscoEnvMonMIB 3 }
|
||||
ciscoEnvMonMIBNotifications OBJECT IDENTIFIER ::= { ciscoEnvMonMIBNotificationPrefix 0 }
|
||||
|
||||
ciscoEnvMonShutdownNotification NOTIFICATION-TYPE
|
||||
-- no OBJECTS
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A ciscoEnvMonShutdownNotification is sent if the environmental
|
||||
monitor detects a testpoint reaching a critical state
|
||||
and is about to initiate a shutdown. This notification
|
||||
contains no objects so that it may be encoded and sent in the
|
||||
shortest amount of time possible. Even so, management
|
||||
applications should not rely on receiving such a notification
|
||||
as it may not be sent before the shutdown completes."
|
||||
::= { ciscoEnvMonMIBNotifications 1 }
|
||||
|
||||
|
||||
ciscoEnvMonVoltageNotification NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
ciscoEnvMonVoltageStatusDescr,
|
||||
ciscoEnvMonVoltageStatusValue,
|
||||
ciscoEnvMonVoltageState
|
||||
}
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"A ciscoEnvMonVoltageNotification is sent if the voltage
|
||||
measured at a given testpoint is outside the normal range
|
||||
for the testpoint (i.e. is at the warning, critical, or
|
||||
shutdown stage). Since such a notification is usually
|
||||
generated before the shutdown state is reached, it can
|
||||
convey more data and has a better chance of being sent
|
||||
than does the ciscoEnvMonShutdownNotification.
|
||||
This notification is deprecated in favour of
|
||||
ciscoEnvMonVoltStatusChangeNotif."
|
||||
::= { ciscoEnvMonMIBNotifications 2 }
|
||||
|
||||
|
||||
ciscoEnvMonTemperatureNotification NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
ciscoEnvMonTemperatureStatusDescr,
|
||||
ciscoEnvMonTemperatureStatusValue,
|
||||
ciscoEnvMonTemperatureState
|
||||
}
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"A ciscoEnvMonTemperatureNotification is sent if the
|
||||
temperature measured at a given testpoint is outside
|
||||
the normal range for the testpoint (i.e. is at the warning,
|
||||
critical, or shutdown stage). Since such a Notification
|
||||
is usually generated before the shutdown state is reached,
|
||||
it can convey more data and has a better chance of being
|
||||
sent than does the ciscoEnvMonShutdownNotification.
|
||||
This notification is deprecated in favour of
|
||||
ciscoEnvMonTempStatusChangeNotif."
|
||||
::= { ciscoEnvMonMIBNotifications 3 }
|
||||
|
||||
|
||||
|
||||
ciscoEnvMonFanNotification NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
ciscoEnvMonFanStatusDescr,
|
||||
ciscoEnvMonFanState
|
||||
}
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"A ciscoEnvMonFanNotification is sent if any one of
|
||||
the fans in the fan array (where extant) fails.
|
||||
Since such a notification is usually generated before
|
||||
the shutdown state is reached, it can convey more
|
||||
data and has a better chance of being sent
|
||||
than does the ciscoEnvMonShutdownNotification.
|
||||
This notification is deprecated in favour of
|
||||
ciscoEnvMonFanStatusChangeNotif."
|
||||
::= { ciscoEnvMonMIBNotifications 4 }
|
||||
|
||||
ciscoEnvMonRedundantSupplyNotification NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
ciscoEnvMonSupplyStatusDescr,
|
||||
ciscoEnvMonSupplyState
|
||||
}
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"A ciscoEnvMonRedundantSupplyNotification is sent if
|
||||
the redundant power supply (where extant) fails.
|
||||
Since such a notification is usually generated before
|
||||
the shutdown state is reached, it can convey more
|
||||
data and has a better chance of being sent
|
||||
than does the ciscoEnvMonShutdownNotification.
|
||||
This notification is deprecated in favour of
|
||||
ciscoEnvMonSuppStatusChangeNotif."
|
||||
::= { ciscoEnvMonMIBNotifications 5 }
|
||||
|
||||
ciscoEnvMonVoltStatusChangeNotif NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
ciscoEnvMonVoltageStatusDescr,
|
||||
ciscoEnvMonVoltageStatusValue,
|
||||
ciscoEnvMonVoltageState
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A ciscoEnvMonVoltStatusChangeNotif is sent if there is
|
||||
change in the state of a device being monitored
|
||||
by ciscoEnvMonVoltageState."
|
||||
::= { ciscoEnvMonMIBNotifications 6 }
|
||||
|
||||
ciscoEnvMonTempStatusChangeNotif NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
ciscoEnvMonTemperatureStatusDescr,
|
||||
ciscoEnvMonTemperatureStatusValue,
|
||||
ciscoEnvMonTemperatureState
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A ciscoEnvMonTempStatusChangeNotif is sent if there
|
||||
is change in the state of a device being monitored
|
||||
by ciscoEnvMonTemperatureState."
|
||||
::= { ciscoEnvMonMIBNotifications 7 }
|
||||
|
||||
ciscoEnvMonFanStatusChangeNotif NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
ciscoEnvMonFanStatusDescr,
|
||||
ciscoEnvMonFanState
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A ciscoEnvMonFanStatusChangeNotif is sent if there
|
||||
is change in the state of a device being monitored
|
||||
by ciscoEnvMonFanState."
|
||||
::= { ciscoEnvMonMIBNotifications 8 }
|
||||
|
||||
ciscoEnvMonSuppStatusChangeNotif NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
ciscoEnvMonSupplyStatusDescr,
|
||||
ciscoEnvMonSupplyState
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A ciscoEnvMonSupplyStatChangeNotif is sent if there
|
||||
is change in the state of a device being monitored
|
||||
by ciscoEnvMonSupplyState."
|
||||
::= { ciscoEnvMonMIBNotifications 9 }
|
||||
|
||||
-- conformance information
|
||||
|
||||
ciscoEnvMonMIBConformance OBJECT IDENTIFIER ::= { ciscoEnvMonMIB 4 }
|
||||
ciscoEnvMonMIBCompliances OBJECT IDENTIFIER ::= { ciscoEnvMonMIBConformance 1 }
|
||||
ciscoEnvMonMIBGroups OBJECT IDENTIFIER ::= { ciscoEnvMonMIBConformance 2 }
|
||||
|
||||
|
||||
-- compliance statements
|
||||
|
||||
ciscoEnvMonMIBCompliance MODULE-COMPLIANCE
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"The compliance statement for entities which implement
|
||||
the Cisco Environmental Monitor MIB. This is
|
||||
deprecated and new compliance
|
||||
ciscoEnvMonMIBComplianceRev1 is added."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS { ciscoEnvMonMIBGroup }
|
||||
::= { ciscoEnvMonMIBCompliances 1 }
|
||||
|
||||
ciscoEnvMonMIBComplianceRev1 MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for entities which implement
|
||||
the Cisco Environmental Monitor MIB."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS { ciscoEnvMonMIBGroupRev,
|
||||
ciscoEnvMonMIBNotifGroup }
|
||||
|
||||
GROUP ciscoEnvMonEnableStatChangeGroup
|
||||
DESCRIPTION
|
||||
"The ciscoEnvMonEnableStatChangeGroup is optional.
|
||||
This group is applicable for implementations which
|
||||
need status change notifications for environmental
|
||||
monitoring."
|
||||
|
||||
GROUP ciscoEnvMonStatChangeNotifGroup
|
||||
DESCRIPTION
|
||||
"The ciscoEnvMonStatChangeNotifGroup is optional.
|
||||
This group is applicable for implementations which
|
||||
need status change notifications for environmental
|
||||
monitoring."
|
||||
|
||||
::= { ciscoEnvMonMIBCompliances 2 }
|
||||
|
||||
-- units of conformance
|
||||
|
||||
ciscoEnvMonMIBGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
ciscoEnvMonPresent,
|
||||
|
||||
ciscoEnvMonVoltageStatusDescr,
|
||||
ciscoEnvMonVoltageStatusValue,
|
||||
ciscoEnvMonVoltageThresholdLow,
|
||||
ciscoEnvMonVoltageThresholdHigh,
|
||||
ciscoEnvMonVoltageLastShutdown,
|
||||
ciscoEnvMonVoltageState,
|
||||
|
||||
ciscoEnvMonTemperatureStatusDescr,
|
||||
ciscoEnvMonTemperatureStatusValue,
|
||||
ciscoEnvMonTemperatureThreshold,
|
||||
ciscoEnvMonTemperatureLastShutdown,
|
||||
ciscoEnvMonTemperatureState,
|
||||
|
||||
ciscoEnvMonFanStatusDescr,
|
||||
ciscoEnvMonFanState,
|
||||
|
||||
ciscoEnvMonSupplyStatusDescr,
|
||||
ciscoEnvMonSupplyState,
|
||||
ciscoEnvMonSupplySource,
|
||||
|
||||
ciscoEnvMonAlarmContacts,
|
||||
|
||||
ciscoEnvMonEnableShutdownNotification,
|
||||
ciscoEnvMonEnableVoltageNotification,
|
||||
ciscoEnvMonEnableTemperatureNotification,
|
||||
ciscoEnvMonEnableFanNotification,
|
||||
ciscoEnvMonEnableRedundantSupplyNotification
|
||||
|
||||
}
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"A collection of objects providing environmental
|
||||
monitoring capability to a cisco chassis. This group
|
||||
is deprecated in favour of ciscoEnvMonMIBGroupRev."
|
||||
::= { ciscoEnvMonMIBGroups 1 }
|
||||
|
||||
ciscoEnvMonMIBGroupRev OBJECT-GROUP
|
||||
OBJECTS {
|
||||
ciscoEnvMonPresent,
|
||||
|
||||
ciscoEnvMonVoltageStatusDescr,
|
||||
ciscoEnvMonVoltageStatusValue,
|
||||
ciscoEnvMonVoltageThresholdLow,
|
||||
ciscoEnvMonVoltageThresholdHigh,
|
||||
ciscoEnvMonVoltageLastShutdown,
|
||||
ciscoEnvMonVoltageState,
|
||||
|
||||
ciscoEnvMonTemperatureStatusDescr,
|
||||
ciscoEnvMonTemperatureStatusValue,
|
||||
ciscoEnvMonTemperatureThreshold,
|
||||
ciscoEnvMonTemperatureLastShutdown,
|
||||
ciscoEnvMonTemperatureState,
|
||||
|
||||
ciscoEnvMonFanStatusDescr,
|
||||
ciscoEnvMonFanState,
|
||||
|
||||
ciscoEnvMonSupplyStatusDescr,
|
||||
ciscoEnvMonSupplyState,
|
||||
ciscoEnvMonSupplySource,
|
||||
|
||||
ciscoEnvMonAlarmContacts,
|
||||
|
||||
ciscoEnvMonEnableShutdownNotification
|
||||
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects providing environmental
|
||||
monitoring capability to a cisco chassis."
|
||||
::= { ciscoEnvMonMIBGroups 2 }
|
||||
|
||||
ciscoEnvMonEnableStatChangeGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
ciscoEnvMonEnableStatChangeNotif
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects providing enabling/disabling
|
||||
of the status change notifications for environmental
|
||||
monitoring."
|
||||
::= { ciscoEnvMonMIBGroups 3 }
|
||||
|
||||
ciscoEnvMonMIBNotifGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS {
|
||||
ciscoEnvMonShutdownNotification
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A notification group providing shutdown notification
|
||||
for environmental monitoring. "
|
||||
::= { ciscoEnvMonMIBGroups 4 }
|
||||
|
||||
ciscoEnvMonStatChangeNotifGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS {
|
||||
ciscoEnvMonVoltStatusChangeNotif,
|
||||
ciscoEnvMonTempStatusChangeNotif,
|
||||
ciscoEnvMonFanStatusChangeNotif,
|
||||
ciscoEnvMonSuppStatusChangeNotif
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of notifications providing the status
|
||||
change for environmental monitoring."
|
||||
::= { ciscoEnvMonMIBGroups 5 }
|
||||
|
||||
ciscoEnvMonMIBMiscNotifGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS {
|
||||
ciscoEnvMonVoltageNotification,
|
||||
ciscoEnvMonTemperatureNotification,
|
||||
ciscoEnvMonFanNotification,
|
||||
ciscoEnvMonRedundantSupplyNotification
|
||||
}
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"A collection of various notifications for the
|
||||
enviromental monitoring mib module. The notifications
|
||||
the group and the group are both in deprecated state.
|
||||
The notifications in the group were deprecated in
|
||||
favour of notifications in
|
||||
ciscoEnvMonStatChangeNotifGroup."
|
||||
::= { ciscoEnvMonMIBGroups 6 }
|
||||
|
||||
END
|
Reference in New Issue