mirror of
https://github.com/librenms/librenms.git
synced 2024-10-07 16:52:45 +00:00
more fixes (thanks sid3windr)
git-svn-id: http://www.observium.org/svn/observer/trunk@571 61d68cd4-352d-0410-923a-c4978735b2b8
This commit is contained in:
246
mibs/SUPERMICRO-HEALTH-MIB.mib
Normal file
246
mibs/SUPERMICRO-HEALTH-MIB.mib
Normal file
@@ -0,0 +1,246 @@
|
||||
-- *****************************************************************
|
||||
-- SUPERMICRO-SMI.mib: Super Micro Enterprise Structure of Management Information
|
||||
--
|
||||
-- October 26 2001, Software LAB
|
||||
--
|
||||
-- Copyright (c) 1993-2001 by Super Micro Computer Inc.
|
||||
-- All rights reserved.
|
||||
--
|
||||
-- *****************************************************************
|
||||
|
||||
SUPERMICRO-HEALTH-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE,
|
||||
Integer32,
|
||||
Gauge32
|
||||
FROM SNMPv2-SMI
|
||||
TEXTUAL-CONVENTION,
|
||||
DisplayString,
|
||||
TruthValue
|
||||
FROM SNMPv2-TC
|
||||
MODULE-COMPLIANCE,
|
||||
OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
smHealth
|
||||
FROM SUPERMICRO-SMI;
|
||||
|
||||
smHealthMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "200110260000Z"
|
||||
ORGANIZATION "Super Micro Computer Inc."
|
||||
CONTACT-INFO
|
||||
" Software Lab
|
||||
|
||||
Postal: 980 Rock Avenue
|
||||
San Jose, CA 95131
|
||||
USA
|
||||
|
||||
Tel: +1 408 503 8000
|
||||
|
||||
E-mail: SoftLab@supermicro.com"
|
||||
DESCRIPTION
|
||||
"MIB module for monitoring health information"
|
||||
::= { smHealth 1 }
|
||||
|
||||
SMHealthInfoTypes ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Represents the different types of health information that
|
||||
may be present in a managed device. The following health
|
||||
information types are currently predefined:
|
||||
0: fan speed
|
||||
1: voltage
|
||||
2: temperature
|
||||
"
|
||||
SYNTAX Integer32 (0..64)
|
||||
|
||||
smHealthObjects OBJECT IDENTIFIER ::= { smHealthMIB 1 }
|
||||
|
||||
smHealthMonitorTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF SMHealthMonitorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table of health monitoring entries."
|
||||
::= { smHealthObjects 1 }
|
||||
|
||||
-- ================
|
||||
smHealthMonitorEntry OBJECT-TYPE
|
||||
SYNTAX SMHealthMonitorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the health monitoring table.
|
||||
Entries cannot be created or deleted via SNMP operations."
|
||||
INDEX { smHealthMonitorIndex }
|
||||
::= { smHealthMonitorTable 1 }
|
||||
|
||||
SMHealthMonitorEntry ::=
|
||||
SEQUENCE {
|
||||
smHealthMonitorIndex Integer32,
|
||||
smHealthMonitorName DisplayString,
|
||||
smHealthMonitorType SMHealthInfoTypes,
|
||||
smHealthMonitorReading Integer32,
|
||||
smHealthMonitorHighLimit Integer32,
|
||||
smHealthMonitorLowLimit Integer32,
|
||||
smHealthMonitorMaxReading Integer32,
|
||||
smHealthMonitorMinReading Integer32,
|
||||
smHealthMonitorDivisor Integer32,
|
||||
smHealthMonitorMonitor TruthValue
|
||||
}
|
||||
|
||||
smHealthMonitorIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..65535)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The unique value which identifies this Monitor device."
|
||||
::= { smHealthMonitorEntry 1 }
|
||||
|
||||
smHealthMonitorName OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A textual full name assigned to the Monitor device.
|
||||
This object is suitable for output to a human operator."
|
||||
::= { smHealthMonitorEntry 2 }
|
||||
|
||||
smHealthMonitorType OBJECT-TYPE
|
||||
SYNTAX SMHealthInfoTypes
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identifies this Monitor device type."
|
||||
::= { smHealthMonitorEntry 3 }
|
||||
|
||||
smHealthMonitorReading OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..65535)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the value from the Monitor device that are
|
||||
currently in use on the managed device.
|
||||
FAN reading is in unit of RPM,
|
||||
Voltage reading is in unit of mV,
|
||||
Temperture reading is in unit of degree C"
|
||||
::= { smHealthMonitorEntry 4 }
|
||||
|
||||
smHealthMonitorHighLimit OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the value for the High limitation
|
||||
for the Monitor device that are currently in use on the
|
||||
managed device.
|
||||
Apply to Temperature and Voltage deivces only.
|
||||
Voltage limit is in unit of mV,
|
||||
Temperture limit is in unit of degree C"
|
||||
::= { smHealthMonitorEntry 5 }
|
||||
|
||||
smHealthMonitorLowLimit OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the value for the Low limitation
|
||||
for the Monitor device that are currently in use on the
|
||||
managed device.
|
||||
FAN limit is in unit of RPM,
|
||||
Voltage limit is in unit of mV,
|
||||
Temperture limit is in unit of degree C"
|
||||
::= { smHealthMonitorEntry 6 }
|
||||
|
||||
smHealthMonitorMaxReading OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..65535)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the value for the possible Maximum reading value
|
||||
for the Monitor device that are currently in use on the
|
||||
managed device.
|
||||
FAN reading is in unit of RPM,
|
||||
Voltage reading is in unit of mV,
|
||||
Temperture reading is in unit of degree C"
|
||||
::= { smHealthMonitorEntry 7 }
|
||||
|
||||
smHealthMonitorMinReading OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..65535)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the value for the possible Minimum reading value
|
||||
for the Monitor device that are currently in use on the
|
||||
managed device.
|
||||
FAN reading is in unit of RPM,
|
||||
Voltage reading is in unit of mV,
|
||||
Temperture reading is in unit of degree C"
|
||||
::= { smHealthMonitorEntry 8 }
|
||||
|
||||
smHealthMonitorDivisor OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the value for the Divisor for the Fan
|
||||
device that are currently in use on the managed device.
|
||||
Apply to Fan devices only."
|
||||
::= { smHealthMonitorEntry 9 }
|
||||
|
||||
smHealthMonitorMonitor OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the monitoring status for the Fan device
|
||||
that are currently in use on the managed device.
|
||||
1 = monitor, 2=do not monitor"
|
||||
::= { smHealthMonitorEntry 10 }
|
||||
|
||||
-- notifications
|
||||
|
||||
smHealthNotifications OBJECT IDENTIFIER ::= { smHealthMIB 2 }
|
||||
|
||||
-- (no notifications are currently defined)
|
||||
|
||||
|
||||
-- conformance information
|
||||
|
||||
smHealthConformance OBJECT IDENTIFIER ::= { smHealthMIB 3 }
|
||||
smHealthCompliances OBJECT IDENTIFIER ::= { smHealthConformance 1 }
|
||||
smHealthGroups OBJECT IDENTIFIER ::= { smHealthConformance 2 }
|
||||
|
||||
|
||||
-- compliance statements
|
||||
|
||||
smHealthCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for entities which implement
|
||||
the Supermicro Health Monitoring MIB"
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS { smHealthMonitorGroup}
|
||||
::= { smHealthCompliances 1 }
|
||||
|
||||
|
||||
-- units of conformance
|
||||
|
||||
smHealthMonitorGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
smHealthMonitorType,
|
||||
smHealthMonitorName,
|
||||
smHealthMonitorReading,
|
||||
smHealthMonitorHighLimit,
|
||||
smHealthMonitorLowLimit,
|
||||
smHealthMonitorMaxReading,
|
||||
smHealthMonitorMinReading,
|
||||
smHealthMonitorMonitor
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects providing Monitor devices."
|
||||
::= { smHealthGroups 1 }
|
||||
|
||||
END
|
55
mibs/SUPERMICRO-SMI.mib
Normal file
55
mibs/SUPERMICRO-SMI.mib
Normal file
@@ -0,0 +1,55 @@
|
||||
-- SUPERMICRO-SMI.mib: Super Micro Enterprise Structure of Management Information
|
||||
--
|
||||
-- October 1995, Software LAB
|
||||
--
|
||||
-- Copyright (c) 1993-2001 by Super Micro Computer Inc.
|
||||
-- All rights reserved.
|
||||
--
|
||||
-- *****************************************************************
|
||||
--
|
||||
|
||||
SUPERMICRO-SMI DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-IDENTITY,
|
||||
enterprises
|
||||
FROM SNMPv2-SMI;
|
||||
|
||||
supermicro MODULE-IDENTITY
|
||||
LAST-UPDATED "200110260000Z"
|
||||
ORGANIZATION "Super Micro Computer Inc."
|
||||
CONTACT-INFO
|
||||
" Software Lab
|
||||
|
||||
Postal: 980 Rock Avenue
|
||||
San Jose, CA 95131
|
||||
USA
|
||||
|
||||
Tel: +1 408 503 8000
|
||||
|
||||
E-mail: SoftLab@supermicro.com"
|
||||
DESCRIPTION
|
||||
"The Structure of Management Information for the
|
||||
Super Micro enterprise."
|
||||
REVISION "200110260000Z"
|
||||
DESCRIPTION
|
||||
"Initial version of this MIB module."
|
||||
::= { enterprises 10876 } -- assigned by IANA
|
||||
|
||||
|
||||
smProducts OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"smProducts is the root OBJECT IDENTIFIER from
|
||||
which sysObjectID values are assigned. Actual
|
||||
values are defined in SUPERMICRO-PRODUCTS-MIB."
|
||||
::= { supermicro 1 }
|
||||
|
||||
smHealth OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"smHealth is the main subtree for new mib development."
|
||||
::= { supermicro 2 }
|
||||
|
||||
END
|
Reference in New Issue
Block a user