diff --git a/mibs/BROADCOM-POWER-ETHERNET-MIB b/mibs/BROADCOM-POWER-ETHERNET-MIB new file mode 100644 index 0000000000..0073c67c6d --- /dev/null +++ b/mibs/BROADCOM-POWER-ETHERNET-MIB @@ -0,0 +1,351 @@ +BROADCOM-POWER-ETHERNET-MIB DEFINITIONS ::= BEGIN + +-- Copyright Broadcom Corporation (2003-2007) All rights reserved. + +-- This SNMP Management Information Specification +-- embodies Broadcom Corporation's confidential and proprietary +-- intellectual property. Broadcom Corporation retains all title +-- and ownership in the Specification including any revisions. + +-- This Specification is supplied "AS IS", Broadcom Corporation +-- makes no warranty, either expressed or implied, +-- as to the use, operation, condition, or performance of the +-- Specification. + + IMPORTS + MODULE-IDENTITY, OBJECT-TYPE, Gauge32 FROM SNMPv2-SMI + TruthValue FROM SNMPv2-TC + fastPath FROM BROADCOM-REF-MIB + pethPsePortEntry, pethMainPseEntry FROM POWER-ETHERNET-MIB; + + + fastPathpowerEthernetMIB MODULE-IDENTITY + LAST-UPDATED "200708191200Z" -- 17 Aug 2007 12:00:00 GMT + ORGANIZATION "Broadcom Corporation" + CONTACT-INFO + " Customer Support + Postal: Broadcom Corporation + 100 Perimeter Park Dr., Suite H + Morrisville, NC 27560 + Tel: +1 919 865 2700" + + DESCRIPTION + "This MIB Augments the POWER-ETHERNET-MIB created by the IETF Ethernet + Interfaces and Hub MIB Working Group for managing Power Source + Equipment (PSE). The objects in this MIB are intended to provide + additional objects for reporting information available to the hardware + on this platform which are not represented in the draft MIB." + + -- Revision history. + REVISION + "200708191200Z" -- 17 Aug 2007 12:00:00 GMT + DESCRIPTION + "PoE support for BCM59101 added." + REVISION + "200705230000Z" -- 23 May 2007 12:00:00 GMT + DESCRIPTION + "Broadcom branding related changes." + REVISION + "200311101200Z" -- 10 Nov 2003 12:00:00 GMT + DESCRIPTION + "Initial revision." + ::= { fastPath 15 } + + agentPethObjects OBJECT IDENTIFIER ::= { fastPathpowerEthernetMIB 1 } + + agentPethPsePortTable OBJECT-TYPE + SYNTAX SEQUENCE OF AgentPethPsePortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of per-port information and configuration objects relating + to the power status of each port." + ::= { agentPethObjects 1 } + + agentPethPsePortEntry OBJECT-TYPE + SYNTAX AgentPethPsePortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A collection of objects providing additional power information + and control parameters for the specified port." + AUGMENTS { pethPsePortEntry } + ::= { agentPethPsePortTable 1 } + + AgentPethPsePortEntry ::= SEQUENCE { + agentPethPowerLimit + Gauge32, + agentPethOutputPower + Gauge32, + agentPethOutputCurrent + Gauge32, + agentPethOutputVolts + Gauge32, + agentPethTemperature + Gauge32, + agentPethPowerLimitType + INTEGER, + agentPethHighPowerEnable + TruthValue, + agentPethPowerDetectionType + INTEGER, + agentPethFaultStatus + INTEGER, + agentPethPortReset + INTEGER + } + + agentPethPowerLimit OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Milliwatts" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The configured maximum power this port can provide to an + attached device measured in Milliwatts." + ::= { agentPethPsePortEntry 1 } + + agentPethOutputPower OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Milliwatts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power this port is supplying to an attached device measured + in Milliwatts." + ::= { agentPethPsePortEntry 2 } + + agentPethOutputCurrent OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Milliamps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current this port is supplying to an attached device measured + in Milliamps." + ::= { agentPethPsePortEntry 3 } + + agentPethOutputVolts OBJECT-TYPE + SYNTAX Gauge32 + UNITS "Volts" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The voltage this port is supplying to an attached device measured + in Volts." + ::= { agentPethPsePortEntry 4 } + + agentPethTemperature OBJECT-TYPE + SYNTAX Gauge32 + UNITS "DEGREES" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The temperature measured at this port of the PoE Controller. It is + measured in degree celcius." + ::= { agentPethPsePortEntry 5 } + + agentPethPowerLimitType OBJECT-TYPE + SYNTAX INTEGER { + dot3af(1), + user(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Describes or controls the maximum power that a port can deliver + A value of dot3af(1) means that the port power limit is as per + the dot3af class of the PD attached. + A value of user(2) means that the port power limit is equal to the value + specified by agentPethPowerLimit" + REFERENCE + "Broadcom 5910X programmers guide, IEEE Std 802.3af Section 30.9.1.1.6" + + ::= { agentPethPsePortEntry 6 } + + agentPethHighPowerEnable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "true (1) The PSE port can deliver power up to 32Watts. + false(2) The PSE port can deliver power up to 18Watts" + REFERENCE + "Broadcom 5910X programmers guide" + + ::= { agentPethPsePortEntry 7 } + + agentPethPowerDetectionType OBJECT-TYPE + SYNTAX INTEGER { + none(0), + legacy(1), + fourPtdot3afonly(2), + fourPtdot3afandlegacy(3), + twoPtdot3afonly(4), + twoPtdot3afandlegacy(5) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Describes PD detection mechanism performed by the PSE port. + A value of none(0) means no detection is done. + A value of legacy(1) means only legacy capacitive detection scheme is + used. + A value of 4ptdot3afonly(2) means that IEEE 802.3af 4point detection scheme + is used. + A value of 4ptdot3afandlegacy(3)means that IEEE 802.3af 4point detection scheme + is used and when that fails to detect a connected PD, legacity capacitive detection + is used. + A value of 2ptdot3afonly(4) means that IEEE 802.3af 2point detection scheme + is used. + A value of 2ptdot3afandlegacy(5)means that IEEE 802.3af 2point detection scheme + is used and when that fails to detect a connected PD, legacity capacitive detection + is used. + The value 'none' can not be forcibly set by the administrator." + REFERENCE + "Broadcom 5910X programmers guide, IEEE Std 802.3af Section 30.9.1.1.6" + + ::= { agentPethPsePortEntry 8 } + + agentPethFaultStatus OBJECT-TYPE + SYNTAX INTEGER { + none(0), + mpsAbsent(1), + short(2), + overload(3), + powerDenied(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Describes the error description when the pse port is in fault status. + A value of none(0) specifies that the pse port is not in any error state. + A value of mpsAbsent(1) specifies that the pse port has detected and absence + of main power supply. + A value of short(2) specifies that the pse port has detected a short circuit + condition. + A value of overload(3) specifies that the pd connected to the pse port had tried + to draw more power than permissible by the hardware. + A value of powerDenied(4) specifies that the pse port has been denied power + because of shortage of power or due to administrative action." + REFERENCE + "Broadcom 5910X programmers guide, IEEE Std 802.3af" + + ::= { agentPethPsePortEntry 9 } + + agentPethPortReset OBJECT-TYPE + SYNTAX INTEGER { + none(0), + reset(1) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A value of reset(1) is used to move the pse port dot3af state to idle. A + read on this object will always return the value none(0). The value none(0) + can not be forcibly set by the administrtor." + REFERENCE + "Broadcom 5910X programmers guide, IEEE Std 802.3af" + + ::= { agentPethPsePortEntry 10 } + + +-- Main objects + agentPethMainPseObjects OBJECT IDENTIFIER ::= { agentPethObjects 2 } + + agentPethMainPseTable OBJECT-TYPE + SYNTAX SEQUENCE OF AgentPethMainPseEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of objects that display and control attributes + of the main power source in a PSE device. Ethernet + switches are one example of boxes that would support + these objects. + Values of all read-write objects in this table are + persistent at restart/reboot." + ::= { agentPethMainPseObjects 1 } + + agentPethMainPseEntry OBJECT-TYPE + SYNTAX AgentPethMainPseEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A set of objects that display and control the Main + power of a PSE. " + AUGMENTS { pethMainPseEntry } + ::= { agentPethMainPseTable 1 } + + AgentPethMainPseEntry ::= SEQUENCE { + agentPethMainPseLegacy + TruthValue + } + + agentPethMainPseLegacy OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/Disable Legacy device detection. The + value true(1) means legacy devices are detected; the + value false(2) means legacy devices are not detected." + ::= { agentPethMainPseEntry 1 } + + agentPethPseTable OBJECT-TYPE + SYNTAX SEQUENCE OF AgentPethPseEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of per-unit information and configuration objects relating + to the power configurtion for the entire pse unit." + ::= { agentPethObjects 3 } + + agentPethPseEntry OBJECT-TYPE + SYNTAX AgentPethPseEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A collection of objects providing additional power information + and control parameters for the specified pse unit." + AUGMENTS { pethMainPseEntry } + ::= { agentPethPseTable 1 } + + AgentPethPseEntry ::= SEQUENCE { + agentPethPsePowerManagementMode + INTEGER, + agentPethPseAutoResetEnable + TruthValue + } + + agentPethPsePowerManagementMode OBJECT-TYPE + SYNTAX INTEGER { + none(0), + dynamic(1), + static(2) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Describes or controls the power management algorithm used by the pse + to deliver power to the requesting PDsthat a pds. + A value of dot3af(1) means that the port power limit is as per + the dot3af class of the PD attached. + A value of user(2) means that the port power limit is equal to the value + specified by agentPethPowerLimit" + REFERENCE + "Broadcom 5910X programmers guide" + + ::= { agentPethPseEntry 1 } + + agentPethPseAutoResetEnable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "true (1) The PSE port is reset with out administrator intervention whenver a + fault condition occurs. + false(2) Administrator has to reset the pse port whenver a fault condition + is detected." + + ::= { agentPethPseEntry 2 } +END