* Added sensors for outlets on Schleifenbauer devices. Also use the outlet name when configured.
* Updated tests for Schleifenbauer
* Fixed on test for Schleifenbauer
* Optimized polling by retriving only outlets from the device with the network connection, not all devices on the data-bus.
* Fixed code styling
* Use shorthand comparisons for names
* Fix for conflicting $entPhysicalIndex
* added support for PDU/PDU2 MIB data (current, power) and added external sensor fpr humidity and temperature on PDU MIB
* added test data of 1 PDU-MIB device and 1 PDU2-MIB device
* Create raritan-pdu.json
* forgot to do save-data on last commit
* Added support for snmp monitored PDU from fs.com
* Added support for snmp monitored PDU from fs.com
* Fix sysObjectID 1.3.6.1.4.1.30966
* Create fs-net-pdu.json
DO NOT DELETE THIS TEXT
#### Please note
> Please read this information carefully. You can run `./scripts/pre-commit.php` to check your code before submitting.
- [X] Have you followed our [code guidelines?](http://docs.librenms.org/Developing/Code-Guidelines/)
#### Testers
If you would like to test this pull request then please run: `./scripts/github-apply <pr_id>`, i.e `./scripts/github-apply 5926`
After you are done testing, you can remove the changes with `./scripts/github-remove`. If there are schema changes, you can ask on discord how to revert.
* refactor: advanced sensor states
mark create_state_index($state_name) as E_USER_DEPRECATED?
* fix: minor corrections
* fix: mib has partialSync(9) and incompatibleVersion(8)
* fix: corrected netagent2upsstate - Sleeping(5)
* fix: NetAgent2 upsThreePhaseUPSStatusInverterOperating correction
* refactor: array() be gone
* Refactoring includes/discovery/sensors/state/extendair.inc.php with arrays
And tidying up array formatting in other files
* fix: minor typo
* standardising array item names
removed redundant "if ($state_index_id !== null) {"
* workaround: procurve & serverscheck
a sensor is causing create_state_index($state) to return null.
The updated code doesn't allow for this and thus a hybrid is being used.
* standardised naming of state info. Caused a typo $state_name instead of $status_name
$state_name is the standard
* converted compas to square arrays
* Converted APC states using preg_match to new create_state_index() call
* Update boss.inc.php
* newdevice: Added support for Alpha Comp@s
http://www.alphainnovations.eu/compas
* fix: Updated state values
state values persist in database, even after deletion of devices.
Not a 100% how to purge them.
create_state_index($state_name, $states) doesn't update the database, if the states have changed
* refactor: comp@s OS state sensor now updated to latest format
* Fix some comment and documentation typos.
* Fix various entphysical page display issues.
- Resolve flickering during loading (missing liClosed for nested items).
- Clicking a sensor actually takes you to the matching graph now.
* Add a few nicecase() calls to clean up html page display.
* Create discover_entity_physical() function
- Add discover_entity_physical() function into includes/discovery/functions.inc.php
- This allows for an easy implementation of OS-specific entity-physical discovery.
- Update includes/discovery/entity-physical/entity-physical.inc.php to use the new function.
* Add power_consumed and power_factor sensors.
* Two new icons, make more entPhysical data visible.
* Pre-commit fix: blank line found at end of control structure.
* Add Schleifenbauer OS support.
* Now really fix the comment typo.
* Fix parsing mistakes.
* Add a generic count sensor.
* Make the Schleifenbauer discovery use count instead of state sensors.
* Don't place count sensor at the top, add sane limits for Schleifenbauer
* Finetuning the rrd_options, changing Schleifenbauer sensor names.
* Update schleifenbauer.svg
* optimize logo too
* add test data
* fix sensor value display (spaces break it)
* update entPhysicalIndex
Fix for issue #8950
DO NOT DELETE THIS TEXT
#### Please note
> Please read this information carefully. You can run `./scripts/pre-commit.php` to check your code before submitting.
- [x] Have you followed our [code guidelines?](http://docs.librenms.org/Developing/Code-Guidelines/)
#### Testers
If you would like to test this pull request then please run: `./scripts/github-apply <pr_id>`, i.e `./scripts/github-apply 5926`
Use Log facility when Laravel is booted.
Update init.php so we can easily boot Laravel for CLI scripts. (and just Eloquent, but that may go away)
Move all debug setup into set_debug() function and use that across all scripts.
Log Laravel database queries.
Send debug output to librenms log file when enabling debug in the webui.
Allow for colorized Log CLI output. (currently will leave % tags in log file output)
** Needs testing and perhaps tweaking still.
DO NOT DELETE THIS TEXT
#### Please note
> Please read this information carefully. You can run `./scripts/pre-commit.php` to check your code before submitting.
- [x] Have you followed our [code guidelines?](http://docs.librenms.org/Developing/Code-Guidelines/)
#### Testers
If you would like to test this pull request then please run: `./scripts/github-apply <pr_id>`, i.e `./scripts/github-apply 5926`
This is a fix for #8746, which added support of SFP module discovery on Procurve devices. I noticed a lot of false positive alerts for current bias when we launched this in production, so looked once more through MIB/code.
MIB data:
hpicfXcvrBias - Tx bias current in microamps
hpicfXcvrBiasHiAlarm - Transceiver bias high alarm threshold limit in microamps
hpicfXcvrBiasLoAlarm - Transceiver bias low alarm threshold limit in microamps
Sensor discovery sample:
hpicfXcvrBias.49 = 23254
hpicfXcvrBiasHiAlarm.49 = 100000
hpicfXcvrBiasLoAlarm.49 = 0
hpicfXcvrBiasHiWarn.49 = 90000
hpicfXcvrBiasLoWarn.49 = 100
So yes, my mistake was to use 10^-7 instead of 10^-6 divisor for these fields. Fix is in this pull request. Sorry for the inconveniences caused.
DO NOT DELETE THIS TEXT
#### Please note
> Please read this information carefully. You can run `./scripts/pre-commit.php` to check your code before submitting.
- [ ] Have you followed our [code guidelines?](http://docs.librenms.org/Developing/Code-Guidelines/)
#### Testers
If you would like to test this pull request then please run: `./scripts/github-apply <pr_id>`, i.e `./scripts/github-apply 5926`
* move routeros fanspeed to yaml
* moved more routeros sensors to yaml
* reverted signal migration to yaml
* added routeros test data
* re-saved test data for routeros
* refactor: Updated discovery to use a core module for sysDescr/sysObjectID use
* final update hopefully
* revert changes
* more changes + docs
* migrated poller to use numerical sysObjectID
* more updates for sysObjectID
* update any alert rules which might have enterprises. in
* moved schema file
* small updates
* updated getHostOS()
* scrut fixes
* updated sysObjectId -> sysObjectID
* updated sysObjectId -> sysObjectID
* updated remainder of sysObjectId -> sysObjectID
* another sysObjectId -> sysObjectID
* fixed secureplatform test data
* Fix tests: $device is not pulled from the database before polling
Also, update the db in the core discovery module.
* Junos dwdm interface sensor support …
four new sensors
Chromatic Dispersion ps/nm
Delay s (seconds)
Q_factor (dB)
preFEC_BER (ratio)
reuse of
SNR, dbm, temperature, current
* new dwdm sensors more generic, ber and quality_factor
* new sensors updated
* renamed html graphs new sensors
* fixed ber polling
* Change to base SI Hz and s.
* update sensor divisors to bigint
* rename sql-schema/216.sql to 218.sql
* YAML junos dwmd sensor definitions, except BER
* bigint divisor fixed
* deafult 1 divisior
* small fixes including schema change for another PR
* schema fix
* Don't do uneeded snmp queries
sensors discovery 26 -> 16
wrapped some poller modules in db checks. The same could be done for some others, but more work is needed.
* travis fix
* refactor: rfc1628 tidy up
reduce the amount of snmp calls
* Did not finish re-writing rfc1628 load
* fix type in bypass power oid
* remove testing changes
* ADVA device support
- sensors for temperature, voltage, current and dbm
- ADVA mibs for FSP150CC and FSP3000R7
* sysObjectId - changed to level above instead of two entries
* OS for FSP150 and FSP3000R7 now in two seperate OS definitions
- split the files
- removed sysObjectId check for each
- removed hardcoded sensor limits
- removed more generic MIBs
* standardized variables / corrected declarations
* added missing MIB, style check code
* - corrected 'current' readings by adding $devisor
- changed rrdfile names to sensorname+$index
- moved LLDP-V2 mibs to main mib directory
* Eaton UPS cleanup
* newdevice: Eaton/MGE UPS cleanup
MGE split Galaxy (and Upsilon) to apc-mgeups
All others to eaton-mgeups
Remove mge ups from eatonups os.
Remove powerware it is a duplicate of eatonups
* Add rfc1528 for both mgeups os
* Update overview graphs
* New Device Support for ICT DC Distribution Panels
* Fixed indexes, removed tests
* Supply name instead of oid to snmp_get call
* Fixed index conflict for current sensors
* Fix Generex votage sensor divisor and add an exclusion option
* Allow OID to be used to figure out if we need to change the divisor.
* Missed current and found bugs while I was there.
* Use returns swap oid logic
* refactor: Tidy up sensor discovery
* more files
* removed uneeded files
* updated array check
* updates for linux/supermicro
* small changes
* Update linux.inc.php
* Add supermicro temps back to linux.inc.php
* No need for is_file on rfc1628.inc.php, it exists
* Revert rfc1628 change
* Fix whitespace...
* rebased
* fixed $valid data not being passed to new sensors() function