* New OS: QTECH
https://www.qtech.ru/en/catalog/
* QTECH: Add hardware, version and serial support
* QTECH: Fix platform and software version detection
* QTECH: Add test for QSW-3450
Fixes issues observed in LibreNMS (timeouts, missing data)
Manual snmpwalk vs. snmpbulkwalk confirmed no bulk support
Missing toner, network, etc. information now seen in LibreNMS!
* MPLS updates and bugfixing
* Tests
* tests
* code climate, tests
* tests
* tests
* remove nokiaIfName(), fetch ifName from the database instead
* restore from messed rebase
* tests
* btw, fix travis about the missing docs
* tests
* tests
* clean the messed up test data an generate new for timos
* rebase
* SIAE add additional sensors and data
Improved labels
Modulation
Rate
Serial Number
Hardware name
* Add total rates
* was supposed to be divisor
* Short array syntax
* Support FreeNAS/TrueNAS 11.3
Seems the latest release changes the SysObjectID from FreeBSD to
their own enterprise number.
I've left the old FreeBSD enterprise number in place, so both
older and newer releases will be detected.
* Test data
It's also possible to do zpool IO from the MIB, but diskIO on
LibreNMS makes a lot of assumptions about it coming from the UCD
MIB.
This changeset adds detection for FreeNAS and TrueNAS - despite
having their own enterprise number, the snmpd uses the FreeBSD
one.
The naming is a bit all over the place, because this reflects
reality - IXSystems produce FreeNAS and TrueNAS, the product lines
have merged to eliminate FreeNAS, but TrueNAS still calls itself
FreeNAS everywhere except the GUI.
* opengear MemPools
Discovery and Polling of opengear mempools - opengear Detail Memory Usage is already collected however that can not be used to trigger rules.
* add test
opengear mempools tests
* remove newline
* Add OS detection for Greenbone appliances
They don't expose anything fancy over SNMP, but this makes them
display interface names correctly. Under the hood they're unix-y.
Greenbone logo is from the AGPLv3 gsa, which is GPL compatible:
https://github.com/greenbone/gsa/blob/master/gsa/public/img/greenbone.svg
The mib is included for completeness, but it doesn't expose any
graphable values.
* Fix the vendor's logo
* BGP Polling: Add error code polling
* Rework describe_bgp_error_code and fix bgp error fields migration
* Add real test data for IOS-XR and Arista EOS
* OS detection and sensors for Dell Compellent
... or Dell storage as it is now known. Under the hood it's
referred to as Compellent, so I've named it as that to avoid
confusion.
It is not part of the Dell group or using the Dell MIB folder -
Dell have doubled up on some OID definitions, which means the MIB
here and a couple of the existing ones conflict.
The change adds OS detection and a frankly ludicrous amount of
sensors. I have access to a relatively low end device, so at the
moment everything under *ctlr* is my best guess based on the other
table layouts.
* Set sensor state_name to avoid collisions
* Regenerate test data
* Add Advantech logo.
Taken from https://commons.wikimedia.org/wiki/File:Advantech_logo.svg
with minor edits (removed width and height).
* Add Advantech MIB files.
* Add Advantech definitions.
* Add suppor for version and hardware polling.
* Add advantech snmp recording.
* Add sensors for SFP ports
Each SFP will have temperature, voltage, tx bias, Tx/Rx power.
Also update snmp recording to include new data.
* Rename ADVANTECH-EKI-PRONEER-MIB_1_01.mib to ADVANTECH-EKI-PRONEER-MIB
* Rename advantech-common-mib.mib to ADVANTECH-COMMON-MIB
* Update advantech.yaml
* Update advantech.svg
* Create advantech.json
Co-authored-by: PipoCanaja <38363551+PipoCanaja@users.noreply.github.com>
* Added support for ICT Modular Power System and ICT Sine Wave Inverter
* Added SNMP test data for ICT Modular Power System and ICT Sine Wave Inverter
* Fixed styling errors and refactored state sensor for ICT Sine Wave Inverter
* Fixed newly created styling issues from refactoring ICT Sine Wave Inverter files.
* Fixed further styling errors from previous changed to appease Travis CI
* Removed unnecessary math from ICT Sine Wave Inverter voltage sensor
* Cleaned up unnecessary lines in ict-mps/ict-swi sensors. Moved from snmp_get to snmp_get_multi in ict-mps/ict-swi os pollers.
* Added test data for ICT MPS and SWI
* Fixed issue with load sensor not discovering
* Update snmpget to snmp_get
Co-Authored-By: Jellyfrog <Jellyfrog@users.noreply.github.com>
* Updated test data post-fixing sensor detection issue on ICT Sine Wave Inverters
* Moved ict-swi and ict-mps from legacy to yaml sensors
* Removed legacy code for ict-mps and ict-swi sensors
* Last commit mistakenly removed OS polling from ict-mps and ict-swi
* Fixed formatting for OS polling and updated test data for ict-mps and ict-swi
Co-authored-by: Jellyfrog <Jellyfrog@users.noreply.github.com>
* ipv6 support for BGP routes in VRP devices
* reverse bgpPeers array to allow VRF aware BGP
* codeclimate
* codeclimate
* codeclimate, finally
* Split VRP out of bgp-peers for readabilty
* Split VRP out of bgp-peers for readabilty
* tests
* CodeClimate
* improve function description
* improve function description
* v6data
* rebase
* space
* ipv6 support for BGP routes in VRP devices
* reverse bgpPeers array to allow VRF aware BGP
* codeclimate
* codeclimate
* codeclimate, finally
* Split VRP out of bgp-peers for readabilty
* Split VRP out of bgp-peers for readabilty
* tests
* CodeClimate
* improve function description
* improve function description
* v6data
* rebase
* space
* fixed corner case
* ascom support
* tests
* typo
* Correct missing 'mpls' in misc/os_schema.json
* remove mpls for now
* tests
* Update ascom.svg
* Don't disable already disabled modules
As I usually state, not much gain in disabling these here. Would be better to optimize the modules if you think they take too long on devices that don't have support.
* refactor polling code
Co-authored-by: Tony Murray <murraytony@gmail.com>
* added functionality to set sysLocation override in $os.inc.php files
* php styling fixes
* updated docs for location override in $os.inc.php
* patch poweralert.inc.php to use $location override
* added location override for enexus (Eltek)
* update phpdoc for set_device_location()
* converged location code in core.inc.php to use set_device_location()
* added new snmprec test data for enexus os
* Travis test data
* remove enexus_smartpacks2 test data
* Revert "remove enexus_smartpacks2 test data"
This reverts commit 36c8fc7036.
* updated enexus_smartpacks2 test data with generic syslocation
* kick travis CI
* kick travis CI
* Changed USV bypass state from alert to warning
* add /opt/librenms/tests/data/dell-ups_tower1000w.json
* add deltaups.json
* orvaldi-ups
* add generex-ups.json
* include two more generex-ups variants
* add eaton-mgeups_5px.json
* add tree more
* add istars.json
* restart hanging CI
* Update OPNsense snmprec, with real data
Update OPNsense snmprec, with real data.
Data from OPNsense 20.1.2 (Latest release at time of commit)
* Update OPNsense definition due to incorrect OID
sysObjectID is incorrect for OPNsense should be .1.3.6.1.4.1.8072.3.2.8. for this snmpget detection to work.
This has been tested in my environment with 2 OPNsense Firewalls.
* Update opnsense.yaml - too add discovery method
Update opnsense.yaml for new OPNsense OID called version.
This will help with detection after the user turns on "Display Verion in OID" within OPNsense
* Re-order to reduce snmp-scan.py time
First, check sysDescr for OPNsense. Then if sysObjectID is 1.3.6.1.4.1.12325.1.1.2.1.1, run an snmpget
* Create opnsense_1.snmprec
Make up test file since data was not supplied
Co-authored-by: Tony Murray <murraytony@gmail.com>