* Added Model number detection to old 3Com SWitches
* Added test data
* Added better way to obtain data from Old 3Com StackSwitches
* Removed debug prints
* Added needed mibs
* Removed mibs and changed to oid in script
* Added Original 3com mibs from http://oidref.com/static/mibdepot/*
* Create 3com_4200.json
* Seafile Monitoring
* generalized function for application with multiple similar entries
* adding snmprec file
* Create linux_seafile-v1.json
* Update linux_seafile-v1.snmprec
Updated linux_seafile-v1.snmprec to use 4x for encoding json data response
* Update Applications.md
* added support for drac power and current polling
* Revert "added support for drac power and current polling"
This reverts commit cf83c1cb82.
* changed discovery to yaml
* readded test data
* Create transition.inc.php
* Update transition.inc.php
This file was copied from another existing file with only the OID changed originally. Cleaned up to remove unnecessary clumsiness.
* Update transition.snmprec
* Update transition.json
* Added model, processor, fan and power supply for Alcatel Omnistack Switches
* Removed Index from description of Fan and power supply
* Merged PR #10655
* Added Temperature Sensor for AOS7+ Alcatel Enterprise Switches
* Added AOS7 mempools
* Added Tests
* Update aos.yaml
* Update alerts levels in state sensors
* Add test data
* added support for PDU/PDU2 MIB data (current, power) and added external sensor fpr humidity and temperature on PDU MIB
* added test data of 1 PDU-MIB device and 1 PDU2-MIB device
* Create raritan-pdu.json
* forgot to do save-data on last commit
* Add ECS4110 cpu usage
* Add cpu usage oid for ECS4110
* TESTED
* Fix EdgeCore ifOperStatus does not follow the Cisco convention
* Since EdgeCore use "lowerLayerDown" in ifOperStatus when port is unplugged
* On the other way, Cisco use briefly "down".
* So change "lowerLayerDown" to "down" to workaround the bug that will make port always show as up/up
* Refactor Edgecos cpu usage oid
* Codeclimate is unhappy about it maybe the refactor will make it happy.
* Add EgdeCore ECS4110 MIB
Just got MIB from EdgeCore
* Refactor Egdecos Mempool
* a bit refactor of Mempool discover and polling
* add support for ECS4110 via MIB
* Modify ECS-4110 MIB
* MODULE-IDENTITY change from ECS4110-52P-MIB to ECS4110-MIB
* strip off syntax error part(time range)
* Add EdgeCore ECS-4110 OS polling
* polling OS and Hardware via MIBs
* Fix typo
* Sorry that I am dazzled
* Fix Syntax Check
* Codeclimate is a bit aggressive
* Update edgecos.inc.php
* Update edgecos.inc.php
* Revert "Fix EdgeCore ifOperStatus does not follow the Cisco convention"
This reverts commit 27971b34a8.
* Add snmprec file for unit testing.
* Create edgecos_ecs4110-28t.json
* Added Cisco QFP processor discovery
* Fix QFP index loop variable name
* Add test data for IOS-XE processors (from ASR1001-HX)
* set the right variable
* additional sensors, some cleanup in yaml
* re-add updated tests/data/enexus_smartpacks2.json
* some rework to avoid regression
* sensor grouping
* update test data
* Add more Vigor series device support
* Update draytek.yaml
* Add more Vigor series device test data
* Update AUTHORS.md
* Update draytek.snmprec
* Create draytek_vigor3900.snmprec
* Added more DELL switches in order to get proper CPU stats
More DELL switches supported:
* N4032
* N2048
* N2024
* N3048
* N2048P
* 54XX
* fixed indent as requested by phpcbf
* fixed multiline argument function call
* removed blank lines
* Added CPU stats for N4064F
* Added test data for N4064F
* fixed indent as requested by phpcbf
* Added test data for Dell Powerconnect 5424
* Added test data for Dell Powerconnect 5448
* Added test data for Dell Powerconnect 5524
* Added test data for Dell Powerconnect N4032
* Added test data for Dell Powerconnect N2024
* Added test data for Dell Powerconnect N2048
* Added test data for Dell Powerconnect N2048P
* Added test data for Dell Powerconnect N3048
* Fixed processor usage data
* Fixed snmpsim data for 3056
* Fixed processor usage
* easier to read format
* remove space changes
* 3056 should be 8%
* Fixed Junos port/vlan relationships for els and non-els based software
* fixed tabs
* Add test data
* Updated test data
* Update module_tables.yaml
* Update junos_qfx5100.json
* Update junos_qfx5100.json
* Update junos_qfx5100.json
* Update opengear MIBs to latest version.
* Replace PHP signal discovery with YAML.
* Update Opengear YAML with new sensors.
* Add test data for Opengear.
* Add the test data json for Opengear.
* Named to numbered index to avoid data loss.
* initial database migrations
* first part, discovery
* second part, polling
* add SAP polling and discovery
* style checks
* rename variables in more generic way
* html global pages for sdp and sdp binds
* add Services and SAPs
* port links, database, etc.
* html device routing pages
* add tests
* checks
* rework database id relationship
* scruntinizer inspection
* fix unit test for new mpls tables
* Update MRV MIBs to version 5.14.1
* Learn SlotTemperature limits from the new MIB.
* Rename MIB files to the name of the MIB.
* Update mrv-od.snmprec
* Update mrv-od.json
* Added support for snmp monitored PDU from fs.com
* Added support for snmp monitored PDU from fs.com
* Fix sysObjectID 1.3.6.1.4.1.30966
* Create fs-net-pdu.json
* Add phase2 name to IPSEC sensor.
For VPN tunnels with more than one phase2, the sensor is confusing.
Using the phase2 value provides both the phase1 and phase2 name for a more complete sensor.
* Update fortigate.yaml
phase1\phase2 naming for a more clear sensor.
test data to come
* add test data
* more test data?
* missing whitespace compared to original
* Remove wireless data