* Update opengear MIBs to latest version.
* Replace PHP signal discovery with YAML.
* Update Opengear YAML with new sensors.
* Add test data for Opengear.
* Add the test data json for Opengear.
* Named to numbered index to avoid data loss.
* Update MRV MIBs to version 5.14.1
* Learn SlotTemperature limits from the new MIB.
* Rename MIB files to the name of the MIB.
* Update mrv-od.snmprec
* Update mrv-od.json
* Added support for snmp monitored PDU from fs.com
* Added support for snmp monitored PDU from fs.com
* Fix sysObjectID 1.3.6.1.4.1.30966
* Create fs-net-pdu.json
* Add phase2 name to IPSEC sensor.
For VPN tunnels with more than one phase2, the sensor is confusing.
Using the phase2 value provides both the phase1 and phase2 name for a more complete sensor.
* Update fortigate.yaml
phase1\phase2 naming for a more clear sensor.
test data to come
* add test data
* more test data?
* missing whitespace compared to original
* Remove wireless data
* Extend the Dell drac module to report CMC status and sensors
* CMC status sensors do not have chassis id
* Update test data for drac OS
* Add missing test data for drac os
* feature: Add a 'session' sensor type
This allows things like the SRX5800 SPU's to be graphed as they expose current and maximum usage in a table.
The intent is to contain things like TTY sessions, flow counters from other vendors, or other resources with support a finite number of simultaneous users or connections.
* Include the node description in the descr field
Chassis clusters use the same FPC's
* Track PanOS session count
* Add JunOS CP Flows
* Missed file containing overview
* Missed a spot
* remove custom sessions sensor and use count
* Update junos.yaml
* Update panos.yaml
* Dynamic entPhysicalIndex values for YamlDiscovery
* Use degree symbol when displaying temperature values
* Adjust SNMP options for new snmp_get_multi()
The OS polling module for mrv-od was using snmpget commands with
-Ovqs, rather than -OQUs, which meant that the equal sign was
stripped in the snmpget output. But that equal sign is now used
as the explode() delimiter so it broke the construction of the
returned array for the snmp_get_multi() function.
Additionally, I removed the NBS-CMMC-MIB:: prefix which is no
longer returned by snmp_get_multi() as part of the OID. Now,
the mrv-od.inc.php OS polling module is retrieving data from
positions in the array with actual content.
* Convert mrv-od to yaml, improve sensors discovery
Converted sensors discovery for mrv-od to yaml, retaining all
functionality for pre-cache, dbm, and temperature. Replaced specific
SFF-8472 Digital Diagnostics state sensors with generic ones, given that
we are now reading out detailed values through new dbm, current, voltage
sensors.
Reasoning: the generic Digital Diagnostics state sensors report state
diagsOk, or else the worst severity level measured among all of the
Digital Diagnostics values for that optical data point. You'd really
only want to set a generic "alarm" so the box can report that it
thinks something is wrong, whereafter a human can look at the graphs
and/or the CLI to draw their conclusions about the alarm. Otherwise,
things would quickly become too spammy as you are essentially duplicating
every sensor across both regular measurements and state measurements.
Further changes:
- Increase maximum number of detected PSUs from 4 to 8 per the MIB.
- State sensor to detect (in)sufficient power budget for all modules.
- Use skip_values to hide state sensors with the notSupported value.
- Use skip_values to hide sensors which are unsupported per the MIB,
signified by the device returning special values -1 or -2147483648.
- Add dBm, temperature "over" graphs to the mrv-od device header bar.
* Add mrv-od entity-physical support
MRV does not use the ENTITY-MIB data format, so we had to reconstruct
the inventory from their proprietary format using the following tables
from their NBS-CMMC-MIB:
- nbsCmmcChassisTable
- nbsCmmcSlotTable
- nbsCmmcPortTable
Additionally, since sensors didn't have their own ifindex in the
NBS-CMMC-MIB, I went ahead and appended the last OID digit to
the "containing" ifindex create a unique number. The same was
done for the sensors in the yaml-discovery.
* Test data for mrv-od, fix 2* pre-commit.php issues
* Fix entPhysicalIndex returning 0 instead of null
Some unit test breakage was caused by 62167ebcb which changed
the code to return 0 instead of null when {{ $index }} was
set as the entPhysicalIndex in the YamlDiscovery. So now we
detect if it returns some value which may be interpreted as
false, and if so we set null rather than 0.
* fix client count polling, add ap count polling.
* Set low warning/critical thresholds for AP count sensors
* Add Aruba AP Count Warning and Critical Alerts to collection, lint alert_rules.json
* add newline at end of alert_rules.json
* add/update tests/data/arubaos*.json test data
* Replace Cyberoam with Sophos (icon and logo)
Cyberoam has been completely incorporated by Sophos since many years.
I'll try to replace everything related to Cyberoam, staring from logo and icon.
* Updated Sophos logo
Updated Sophos logo
* Added Sophos logo
Added Sophos logo
* New OS: Aruba Instant
* New OS: Aruba Instant
* recreate test data
* remove aruba_instant test data
* remove empty file includes/definitions/discovery/aruba-instant.yaml
* fix state sensor discovery
* remove minor changes to includes/polling/functions.inc.phpwq
* move mac helper functions to Rewrite class
* simplify snmpwalk_group usage, general code cleanup
* fixes
* fixes
* fixes
* fixes
* fixes
* fixes
* recreate test data for 105 variant
* Add Client sensors for 8.4.0.0+
* begin stream-lining discovery and polling. separating discovery functions
* update test data
* update test data
* update test data
* improve mempool discovery/polling, clean up os polling, improve state discovery, improve os definition, misc fixes to wireless sensors module
* attempt to implement custom AP and client discovery and polling
* code fixes
* re-add ap count top graph
* more fixes
* more fixes
* more fixes
* more fixes
* remove some debugging, update test data
* code cleanup
* code cleanup
* address some scrutinizer warnings
* Fix Avtech discovery
pre-cache stored the data incorrectly
* Fix RA-4E external sensors
sen1 had incorrect oids (duplicate of sen2)
Description oid from data doesn't match the mib, perhaps outdated MIB?
* add test data
* Updated 4E MIB
* additional sensors for timos
change to yaml discovery for sensors
remove obsolete tmnxChassisPowerSupplyTable
* inconsistent data in snmpsim
* fix snmpsim data
* fix snmpsim data
* fix snmpsim data
* Added support for Zmtel greenpacket devices (os: zmtel)
* added more sensors
* move count sensors to features
* rename MIB and move modulation scheme to state sensor
* added test data
* graph pCID