* Update OPNsense snmprec, with real data
Update OPNsense snmprec, with real data.
Data from OPNsense 20.1.2 (Latest release at time of commit)
* Update OPNsense definition due to incorrect OID
sysObjectID is incorrect for OPNsense should be .1.3.6.1.4.1.8072.3.2.8. for this snmpget detection to work.
This has been tested in my environment with 2 OPNsense Firewalls.
* Added bad_iftype to iosxe.yaml definition
* Update Configuration.md
Updated file location from includes/defaults.inc.php to misc/config_definitions.json and added an example of OS specific bad_iftype entries.
* Added OS Specific example for ignoring interfaces and updated file location.
* Updated bad_if selection documentation
* Update opnsense.yaml - too add discovery method
Update opnsense.yaml for new OPNsense OID called version.
This will help with detection after the user turns on "Display Verion in OID" within OPNsense
* Re-order to reduce snmp-scan.py time
First, check sysDescr for OPNsense. Then if sysObjectID is 1.3.6.1.4.1.12325.1.1.2.1.1, run an snmpget
* Create opnsense_1.snmprec
Make up test file since data was not supplied
Co-authored-by: Tony Murray <[email protected]>
* Adding support for Cisco SB SX550X-24F switch
This pull request adds support for Cisco Small Business SX550X-24F switch by adding sysObjectID .1.3.6.1.4.1.9.6.1.1001 in the ciscosb discovery module.
* Added ciscosb_sx550x-24f.snmprec file
* Added ciscosb_sx550x-24f.json
* Updated ciscosb_sx550x-24f.json
* update ciscosb_sx550x-24f.snmprec
* Collected new ciscosb_sx550x-24f.snmprec file
* updated test data
* Added rittal-cmc (LCP Plus)
skip_values opperand 'not_in_array' returns an error in pre-commit but in principal it's running. Can someone help?
1) LibreNMS\Tests\YamlTest::testDiscoveryDefinitionSchema
rittal-cmc.yaml does not validate. Violations:
[modules.sensors.fanspeed.data[0].skip_values[0].value] Array value found, but an integer or a string is required
[modules.sensors.temperature.data[0].skip_values[0].value] Array value found, but an integer or a string is required
[modules.sensors.temperature.data[1].skip_values[0].value] Array value found, but an integer or a string is required
[modules.sensors.temperature.data[2].skip_values[0].value] Array value found, but an integer or a string is required
[modules.sensors.temperature.data[3].skip_values[0].value] Array value found, but an integer or a string is required
* fix Scrutinizer Inspection
* fix codeclimate
* fix typo
* Update discovery_schema.json
To allow arrays in comparisons
* Control structures
* fix the pre-fix issues
* Typo in copy/paste
* Update rittal-cmc.json
* Unit1,2,3,4 and new snmprec, json have not changed
* Update rittal-cmc.json
Correct JSON data
* typo copy paste
Co-authored-by: PipoCanaja <[email protected]>
* Added WUT 57606,57613,57720
* Added os wut-*
* fixed MIB Names and try to generalize wut
* more general sysObjectID mapping, and mib directory
* Delete WUT-57606-MIB
* Delete WUT-57613-MIB
* Delete WUT-57720-MIB
* Rename wut-57613.snmprec to wut_57613.snmprec
* Rename wut-57720.snmprec to wut_57720.snmprec
* Rename wut-57606.snmprec to wut_57606.snmprec
* Delete wut-57606.yaml
* Delete wut-57720.yaml
* Delete wut-57613.yaml
* Delete wut-57606.yaml
* Delete wut-57720.yaml
* Delete wut-57613.yaml
* Update wut.yaml
* Try to correct the Temperature part
This should work for temperature, according to MIB. Pressure and Humidity are not described in this mibfile, so we cannot poll them.
* change wut.yaml
* Add and fix wut_57720
* after ./scripts/save-test-data.php ?
* Add test data
Co-authored-by: PipoCanaja <[email protected]>
* Migrate ironware sensor discovery from php to yaml.
* More sensors, add grouping.
* dynamic_discovery_get_value() becomes getValueFromData()
* Target a specific index with skip_values.
* Improve Brocade BGP session discovery/polling
This commit allows for the correct discovery of BGP sessions
with 32-bit ASNs, IPv6 neighbors using the BGP4V2-MIB which is
based on draft-ietf-idr-bgp4-mibv2-11 and also polls for IPv4
unicast received routes through the FOUNDRY-SN-BGP4-GROUP-MIB.
Copied most of the code from PR#8877 by @Mikeburke14, cleaned
up the code a little bit to match the normal LibreNMS style,
and fixed bgpPeers_cbgp discovery as well as polling for the
ipv4.unicast neighbors.
Note that older Brocade IronWare firmware versions are known
to have multiple defects relating to the BGP4V2-MIB which
might result in certain missing non-established neighbors.
Related vendor defect numbers:
- DEFECT000633962
-- Symptom: The OID bgp4V2PeerAdminStatus does not return the
correct value
-- Reported: NI 05.7.00
-- Resolved: NI 05.8.00g
- DEFECT000583319
-- Symptom: SNMP polling on bgp4V2PeerTable (OID brcdIp.3.5.1.1.2)
does not display all the BGP entries
-- Reported: NI 05.6.00
-- Resolved: NI 05.8.00e
- DEFECT000550309
-- Symptom: SNMP polling on bgp4V2PeerTable (OID brcdIp.3.5.1.1.2)
does not display the full information
-- Reported: NI 05.7.00
-- Resolved: NI 05.8.00c
* Add ironware CER & ICX platform test data.
* Re-add ironware.json compatible with current master branch.
* Added definition and sensors for SIAE Alfoplus80HD
* updated the units for the wireless rate sensor
* Added test data
* regenerated test data as requested by PipoCanaja
* Update nios.yaml
I tried to pull them all in using {{ index }}, but it didn't actually work.....
This adds the DHCP, DNS and NTP service statuses.
* Dynamic service discovery
* typo
* Create nios_status.snmprec
* Create nios_status.json
* Array
* Typo, more
Co-authored-by: PipoCanaja <[email protected]>
* extend FS switches support
* MIB compilation
* HW and Ver
* sensors and CPU
* tests
* correct version
* try to handle properly "down" as not up, for OperStat like lowerLayerDown
* try to handle properly "down" as not up, for OperStat like lowerLayerDown
* try to handle properly "down" as not up, for OperStat like lowerLayerDown
* try to replace "down" with "not up" :)
* fix other ifOperStatus checks
* Add support for TRENDnet switch, TEG-S80ES in particular
* Add trendnet.snmprec
* Add test data (JSON)
* Remove mib comment from yaml
* Update copyright info
* Use sysDescr value for Hardware
* Categorise Cisco WLC as wireless, like all the other controller-based wireless platforms.
* RSS notification for Cisco WLC change of classification
* Update notifications.rss