* Add support for PrimeKey Hardware Appliance
https://doc.primekey.com/ejbca-appliancehttps://doc.primekey.com/signserver-appliancehttps://doc.primekey.com/ejbca-appliance/operations/webconf-configurator-of-hardware-appliance/monitoring
* Correct off-by-one error for Galera states
* Add load multiplier
* Don't poll transaction ID, it's too messy
* Tabs -> spaces
* Don't modify system load. (Is this a %age or not?)
* CUP moves Load -> Count
* CPU moves Load -> Count
* Now I have MiBs. Attempts to use them are to date unsuccessful
* Removed numeric oids entirely
I'm not sure how easy it will be to conver this to YAML.
* Formatting
* More formatting
* Numeric it is
* Fix States
* Numeric oids
* Shorten Descriptions
* Add DB threshold
* Percent -> Yaml
* Temperature -> Yaml. Relaxed num_oid validation
* Fanspeed -> Yaml
* Volgate -> Yaml
* Count -> Yaml
* State -> Yaml
* Tweak snmp_flags
* minimize icon
* Check if first_word function is required
* Incorporate feedback
Co-authored-by: Tony Murray <murraytony@gmail.com>
* Add DBm and State Sensors
Added extra MIB files
Added Dbm levels on ports
Added Stacking State Sensors
* Added include for zynos.inc.php
File patch - includes/discovery/ports/zynos.inc.php
* Create ZYXEL-STACKING-MIB
Official Zyxel MIB
* Create ZYXEL-TRANSCEIVER-MIB
Official Zyxel MIB
* Added test file zynos_xgs4600.json
* Create zynos snmprec test file
* CENSORED zynos_xgs4600.json
* Created new polling file for Zynos ports
Converts zynos SWP port style to be 1/1 style
* Created new discovery for Zynos ports
Changes zynos SWP ports to be 1/1 style during discovery
* Fixing ci complaints in discovery/ports/zynos.inc.php
* Fixing ci complaints in polling/ports/os/zynos.inc.php
* fixing more ci complaints in discovery
* Updated Zynos.snmprec
* Updated zynos.json
* Updated zynos.json
* Removed ifDescr pre-cache
* Removed pre-cache from zynos.yaml
* Reverted zynos.snmprec
* Restored zynos.json
* Updated zynos polling to use zeropad
* Updated zynos discovery to use zeropad
* Updated zynos.yaml
Updated zynos.yaml to include ifname: true to change port names and added '/^ZyXEL/' to sysDescr_regex
* Update zynos.inc.php
* Update zynos.inc.php
* Update zynos_xgs4600.json
* Update zynos_xgs4600.snmprec
* Re-Generated Zynos.json
* Fixed ifOperStatus in Zynos.json
* Delete zynos.inc.php
* Update ports.inc.php
* Added new test data
* Updated zyxel test data and discovery
* Update ports.inc.php
* Update zynos.snmprec
* Updated zynos.json
* Update Zynos.json
* Fix StyleCI issues
* Update zynos.json
* Update zynos.json
* Update zynos.json
* Updated zynos mgs3712.json
* Update zynos_mgs3712.json
* Added back old SFP discovery
-SFP Temperature
-SFP Voltage
* Migrate addhost.php to lnms device:add
Have snmp-scan.py call lnms device:add (make exit codes line up so this works)
Fix issue with ping only devices trying to detect os via snmp
Reorder options in device:add help and improve formatting
Update docs to remove references to addhost.php
Fix a bit of code that was in functional code
* fixes
* fix snmp version message
* Fixeed Hardware and Versiondetection for US-8 and USW-Switches with Version 5
It seems that the same model and same firmware version respond with different SNMP-records, depending on Hardware revision. This should be more general
* removed "linux" from version string in some cases
Changed regex for better version isolation and updated test data
* Update edgeswitch.yaml
Corrected the edgeswitch Test-Version detection. It seems that there are 4 cases :(:
USW GigaBit Ethernet Switch, firmware 5.76.7.13442
US-8, 5.76.7.13442, Linux 3.6.5
USW-Flex 5.76.7.13442
EdgeSwitch 24-Port 250W, 1.0.1.4720839, Linux 3.6.5-f4a26ed5
* Removed false change. Changed 8XP test data
Removed false change. Changed 8XP test data
* ' -> "
' -> "
Extreme changed the name on universal hardware(5520, 5420, 5320) when running VOSS 8.6 software or greater to FabricEngine for universal hardware only. This change removed VOSS in system description and added the word FabricEngine. So previous a switch with sysDescr of 5520-24X-VOSS became 5520-24X-FabricEngine.
General Info :
SysDescr : 5520-24X-FabricEngine (8.6.0.0)
SysName : 5520X-Traffic-VSP
SysUpTime : 0 day(s), 15:59:25
SysContact : http://www.extremenetworks.com/contact/
SysLocation : some location
* API: device_add support display field
remove legacy code path
update docs
A few improvements to the new code too
* some fixes, port_association_mode was not available
* hand version -> snmpver translation
* Add support for IPMIv2 Kg Key in device settings
Some devices require that the Kg key be specified. An example would be a server of mine, a Cisco C220 M3.
Otherwise, it would error out with `Error: Unable to establish IPMI v2 / RMCP+ session`.
With verbose output enabled, the connection attempt would stop at `RAKP 4 message has invalid integrity check value`.
* Add Kg key support in Poller
* Sanitize Kg key from debug output
* Added Kg key support for discovery process
And it seems to work like a charm. New fields, such as fan tachometers, were added in automatically.
* Applying StyleCI changes
* New device:add code
pre-requisite for updating other code paths
includes option to set display name
separate validation code from device creation
* remove duplicate community and v3 creds
* style fixes
* some lint fixes
* fix phpstan
* Exception cleanup
improved messages and translations
* port association mode to enum
well, pseudo enum
* defaults and cleanups
* fixed/improved validation messages
* fix tests
* fix stupid ide refactor mistake
* lint fixes
Mistake on $class variable, value was 'er' instead of 'ber'.
This error prevented the ber graph located at Devices->Health->Overview
to correctly appear.
* Update vertiv-pdu.yaml
VERTIV-V5-MIB states UNITS "decivolts (rms)" for pduPhaseVoltage
* Update vertiv-pdu_mn03edr1.json
Updated test data
Co-authored-by: Neil Lathwood <gh+n@laf.io>
* Add EntityVoltage Sensors
* Add BoardPower Sensors
* Add Fanspeed Percent sensor
* Add Voltage_Status and Temperature_Status Normal|Minor|Major|Critical indicators, and internal Voltage and Temperature sensors
* set Minor alarm violations to warning status
* remove inconsistently applied empty lines between sections, and trailing newline that caused errors
* fetch thresholds for temperature.sensors and optical.RxPower from SNMP
* Added snmp testfiles for ne8000-m8 variant of VRP platform
* group sensors by card-identifier
* Regenerate testfiles for 5720-32x-ei
* Regenerate testfiles for the whole VRP family
* Optical Bias is reported as miliamps-mA, and not microamps-uA
* Implement divisor detection, VRP or NE8 prepended on sensor for debug-testing
* remove VRP or NE8 prependeds on sensors(put there for debug/testing only)
* use parent OIDs for walking and naming
* ignore per-slot power if unsupported
* regenerated snmp json testfiles
* sanitize bgp-peers value
* restore vrp.json test
Co-authored-by: PipoCanaja <38363551+PipoCanaja@users.noreply.github.com>
* Moved plugin admin pages to be within admin route
* Wrap html transports page in admin check
* Moved Port group controller to be admin protected
* fixed tests
* XSS in alert template creation
* XSS in alert rule name
* XSS in service name & desc
* style
* strip_tags in alert_notes
* strip_tags in create_alert_item
* strip_tags in addsrv page
* [WebUI] Removing the colon symbol from dialogs
In order to make multiple pages more visually consistent with other pages in the system, removed the colon simbol ":" to the very right of each control description, where present.
Regards
GG
* Update new_alert_rule.inc.php
* Update alert_schedule.inc.php
* Update alert_template.inc.php