* Clean broken VRF lite code
* Change DB table for route discovery
* Add VRF simple support
* add port_id to db and discovery
* static-fy the translation arrays
* sort and search cleaning
* Sorting refactor and validation
* formatItem shortened
* Handle ifIndex==0 meaning no next hop defined (MPLS)
* Sync all create/updates
* purge in daily
* remove old route table
* get rid of inetCidrRouteNextHop_device_id
* fix wonky column orders
* add route snmprec
* fix sorting by interface
* Move to new config
* rename to route the new table
* Properly display ipv6 compressed addresses
* Translation before merge ./lnms translation:generate
* Update manifest
* Device Cache
also some additional device related models
* attribs from cache
* replace common attribute functions
* remove legacy cache usage
tidy up some collection manipulation
remove some unused or single use functions
* cleanup some items
* always return a device, to prevent bugs
* clear device cache when testing after each test
* fix double assignment
* Clean up function to take advantage of null object
* - update yzyxel mibs
- update definitions für ies series
- slot state and alarm support via yaml
* more sensors
* add new device Zyxel IES4206
* restore original ies files
* revert function stuff
* update to latest official mib
* rebase
* Added model, processor, fan and power supply for Alcatel Omnistack Switches
* Removed Index from description of Fan and power supply
* Merged PR #10655
* Added Temperature Sensor for AOS7+ Alcatel Enterprise Switches
* Added AOS7 mempools
* Added Tests
* Update aos.yaml
* Update alerts levels in state sensors
* Add test data
* added support for PDU/PDU2 MIB data (current, power) and added external sensor fpr humidity and temperature on PDU MIB
* added test data of 1 PDU-MIB device and 1 PDU2-MIB device
* Create raritan-pdu.json
* forgot to do save-data on last commit
* add ability to discover percent warning on mempools discovery
* remove wierd charachters from json
* remove database defaults, add defaults for Linux and Vmware
* update db schema
* update test data
* adapt hrstorage mempools
* rebase
* Add ECS4110 cpu usage
* Add cpu usage oid for ECS4110
* TESTED
* Fix EdgeCore ifOperStatus does not follow the Cisco convention
* Since EdgeCore use "lowerLayerDown" in ifOperStatus when port is unplugged
* On the other way, Cisco use briefly "down".
* So change "lowerLayerDown" to "down" to workaround the bug that will make port always show as up/up
* Refactor Edgecos cpu usage oid
* Codeclimate is unhappy about it maybe the refactor will make it happy.
* Add EgdeCore ECS4110 MIB
Just got MIB from EdgeCore
* Refactor Egdecos Mempool
* a bit refactor of Mempool discover and polling
* add support for ECS4110 via MIB
* Modify ECS-4110 MIB
* MODULE-IDENTITY change from ECS4110-52P-MIB to ECS4110-MIB
* strip off syntax error part(time range)
* Add EdgeCore ECS-4110 OS polling
* polling OS and Hardware via MIBs
* Fix typo
* Sorry that I am dazzled
* Fix Syntax Check
* Codeclimate is a bit aggressive
* Update edgecos.inc.php
* Update edgecos.inc.php
* Revert "Fix EdgeCore ifOperStatus does not follow the Cisco convention"
This reverts commit 27971b34a8.
* Add snmprec file for unit testing.
* Create edgecos_ecs4110-28t.json
* do not discover dbm sensors on shutdown ports
* rename confusing name from $sensor_type to $sensor_class
* Revert "do not discover dbm sensors on shutdown ports"
This reverts commit 46963f746a.
* Fixed foreach loop throwing errors when no vlans present, community id post 9528
* Added extra else / debug statement for validation
The modified changes allow for clear information regarding the discovery of devices where no port<->L2 Access/Trunk association is seen.
* Fixed Junos port/vlan relationships for els and non-els based software
* fixed tabs
* Add test data
* Updated test data
* Update module_tables.yaml
* Update junos_qfx5100.json
* Update junos_qfx5100.json
* Update junos_qfx5100.json
* Update opengear MIBs to latest version.
* Replace PHP signal discovery with YAML.
* Update Opengear YAML with new sensors.
* Add test data for Opengear.
* Add the test data json for Opengear.
* Named to numbered index to avoid data loss.
* Added support for snmp monitored PDU from fs.com
* Added support for snmp monitored PDU from fs.com
* Fix sysObjectID 1.3.6.1.4.1.30966
* Create fs-net-pdu.json
* Added support for DGD and BER that are avalible on newer infinera-groove FW
* updated tests for new groove sensors
* Update infinera-groove.inc.php
* Update infinera-groove.inc.php
* Force test to run again
* Default to null for group yaml discovery.
* Update test data for a154bda yaml group null fix.
* Changes to guessed limit functions for sensors.
Original behaviour
===================
The file `includes/discovery/functions.inc.php` contains
`sensor_limit_low()` and `sensor_limit()` which both attempt to
guess a sane value for sensors when no explicitly defined
low_limit or high_limit can be found during discovery.
Both switch control structures used in those two functions
have empty case statements which means that if one of those matches,
it's going to fall through and run the code for each subsequent
case until a `break` is reached.
For example, when we call `function sensor_low_limit(dbm, -13.036)`
it will return the value `-12.3842` instead of `null`. That is
because there will be a match at `case 'dbm':` which falls through
all the way to `case 'cooling':`, where it performs
`$limit = -13.036 * 0.95` before hitting a `break`.
Changed behaviour
===================
Removed `power_consumed` and `count` guessed low_limit and
high_limit, I personally added those sensor classes in PR #9471
when I didn't understand that a switch control structure has
fall-through behaviour so I can guarantee that guessing limits for
those is a mistake on my behalf. It should not be there, only
power_factor can have guessed limits. Apologies for the issue,
I'm still a beginning programmer!
Furthermore, I removed guessed high_limit values for `current`
and `power` because these are supposed to draw higher values as
more devices or components are installed on for example a PDU or
a chassis.
Finally, I removed guessed low_limit and high_limit for `dbm`
sensors, there is a much too large variance in power budget on
commercially available optical transceivers for there to be a
sensible window where you can guess these values.
* Documentation on adding sensor classes.
* Update test data - sensor limit changes @ 30212d2
* Aruba IAP: Fix Radio State Sensor
Fix state sensor for radio status from warning when disabled to unknown state.
* Update aruba-instant.json
* Update aruba-instant_105.json
* WIP - Add MPLS Support
This introduce the generic MPLS support
- New database tables for MPLS LSPs
- actually discovery and polling on NOKIA SR OS (Timetra) devices
- new routing->MPLS HTML pages
- ToDo MPLS LSP paths table and views
Suggestions and improvements are welcome
* add db schema
* some fixes
* add path table, discovery and polling
* add path views
* add test data
* Convert MPLS module to new style
Implement a SyncsModels trait to simplify code a lot
* abs() for negative value from snmp (bug?), test data
* fix db schema
* Fix up test data, remove uneeded data in json
* fix whitespace