{ "os": { "discovery": { "devices": [ { "sysName": "", "sysObjectID": ".1.3.6.1.4.1.2634.6.8", "sysDescr": "Linux 10.40.254.74 2.6.33-ts-powerpc #478 Mon Jun 27 16:48:56 PDT 2011 ppc", "sysContact": "", "version": null, "hardware": "VMR-8HD20", "features": null, "location": "", "os": "wti-power", "type": "power", "serial": null, "icon": "wti.svg" } ] }, "poller": "matches discovery" }, "sensors": { "discovery": { "sensors": [ { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.200.20.0", "sensor_index": "environmentBranchATotalCurrent.0", "sensor_type": "wti-power", "sensor_descr": "Branch A Current", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.200.40.0", "sensor_index": "environmentBranchBTotalCurrent.0", "sensor_type": "wti-power", "sensor_descr": "Branch B Current", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 1.1, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.200.60.0", "sensor_index": "environmentSystemTotalCurrent.0", "sensor_type": "wti-power", "sensor_descr": "Total Unit Current", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 1.1, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.7.1", "sensor_index": "plugCurrent.1", "sensor_type": "wti-power", "sensor_descr": "Outlet-A1 Current", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.7.2", "sensor_index": "plugCurrent.2", "sensor_type": "wti-power", "sensor_descr": "Outlet-A2 Current", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.7.3", "sensor_index": "plugCurrent.3", "sensor_type": "wti-power", "sensor_descr": "Outlet-A3 Current", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.7.4", "sensor_index": "plugCurrent.4", "sensor_type": "wti-power", "sensor_descr": "Outlet-A4 Current", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.7.5", "sensor_index": "plugCurrent.5", "sensor_type": "wti-power", "sensor_descr": "Outlet-B1 Current", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.7.6", "sensor_index": "plugCurrent.6", "sensor_type": "wti-power", "sensor_descr": "Outlet-B2 Current", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.7.7", "sensor_index": "plugCurrent.7", "sensor_type": "wti-power", "sensor_descr": "Outlet-B3 Current", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 0.7, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.7.8", "sensor_index": "plugCurrent.8", "sensor_type": "wti-power", "sensor_descr": "Outlet-B4 Current", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 0.4, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "power", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.200.30.0", "sensor_index": "environmentBranchATotalPower.0", "sensor_type": "wti-power", "sensor_descr": "Branch A Power", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "power", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.200.50.0", "sensor_index": "environmentBranchBTotalPower.0", "sensor_type": "wti-power", "sensor_descr": "Branch B Power", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 256, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "power", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.200.70.0", "sensor_index": "environmentSystemTotalPower.0", "sensor_type": "wti-power", "sensor_descr": "Total Unit Power", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 256, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "power", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.8.1", "sensor_index": "plugPower.1", "sensor_type": "wti-power", "sensor_descr": "Outlet-A1 Power", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "power", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.8.2", "sensor_index": "plugPower.2", "sensor_type": "wti-power", "sensor_descr": "Outlet-A2 Power", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "power", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.8.3", "sensor_index": "plugPower.3", "sensor_type": "wti-power", "sensor_descr": "Outlet-A3 Power", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "power", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.8.4", "sensor_index": "plugPower.4", "sensor_type": "wti-power", "sensor_descr": "Outlet-A4 Power", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "power", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.8.5", "sensor_index": "plugPower.5", "sensor_type": "wti-power", "sensor_descr": "Outlet-B1 Power", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "power", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.8.6", "sensor_index": "plugPower.6", "sensor_type": "wti-power", "sensor_descr": "Outlet-B2 Power", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "power", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.8.7", "sensor_index": "plugPower.7", "sensor_type": "wti-power", "sensor_descr": "Outlet-B3 Power", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 163, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "power", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.8.8", "sensor_index": "plugPower.8", "sensor_type": "wti-power", "sensor_descr": "Outlet-B4 Power", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 93, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.3.1", "sensor_index": "plugStatus.1", "sensor_type": "plugTable", "sensor_descr": "Outlet-A1 State", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 1, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "plugTable" }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.3.2", "sensor_index": "plugStatus.2", "sensor_type": "plugTable", "sensor_descr": "Outlet-A2 State", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 1, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "plugTable" }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.3.3", "sensor_index": "plugStatus.3", "sensor_type": "plugTable", "sensor_descr": "Outlet-A3 State", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 1, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "plugTable" }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.3.4", "sensor_index": "plugStatus.4", "sensor_type": "plugTable", "sensor_descr": "Outlet-A4 State", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 1, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "plugTable" }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.3.5", "sensor_index": "plugStatus.5", "sensor_type": "plugTable", "sensor_descr": "Outlet-B1 State", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 1, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "plugTable" }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.3.6", "sensor_index": "plugStatus.6", "sensor_type": "plugTable", "sensor_descr": "Outlet-B2 State", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 1, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "plugTable" }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.3.7", "sensor_index": "plugStatus.7", "sensor_type": "plugTable", "sensor_descr": "Outlet-B3 State", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 1, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "plugTable" }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.100.200.1.3.8", "sensor_index": "plugStatus.8", "sensor_type": "plugTable", "sensor_descr": "Outlet-B4 State", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 1, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "plugTable" }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.200.10.1.3.1", "sensor_index": "environmentUnitTemperature.1", "sensor_type": "wti-power", "sensor_descr": "Unit temperature", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 28, "sensor_limit": 48, "sensor_limit_warn": null, "sensor_limit_low": 18, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.200.10.1.5.1", "sensor_index": "environmentUnitVoltageA.1", "sensor_type": "wti-power", "sensor_descr": "Branch A Voltage", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 234, "sensor_limit": 269.1, "sensor_limit_warn": null, "sensor_limit_low": 198.9, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.2634.3.200.10.1.8.1", "sensor_index": "environmentUnitVoltageB.1", "sensor_type": "wti-power", "sensor_descr": "Branch B Voltage", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 233, "sensor_limit": 267.95, "sensor_limit_warn": null, "sensor_limit_low": 198.05, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": null, "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null } ], "state_indexes": [ { "state_name": "plugTable", "state_descr": "outletOff", "state_draw_graph": 0, "state_value": 0, "state_generic_value": 3 }, { "state_name": "plugTable", "state_descr": "outletOn", "state_draw_graph": 0, "state_value": 1, "state_generic_value": 0 }, { "state_name": "plugTable", "state_descr": "outletReboot", "state_draw_graph": 0, "state_value": 2, "state_generic_value": 1 }, { "state_name": "plugTable", "state_descr": "outletUnknown", "state_draw_graph": 0, "state_value": 4, "state_generic_value": 2 } ] }, "poller": "matches discovery" } }