{ "os": { "discovery": { "devices": [ { "sysName": "", "sysObjectID": ".1.3.6.1.4.1.30065.1.3011.7050.1958.128", "sysDescr": "Arista Networks EOS version 4.15.3F running on an Arista Networks DCS-7050TX-128", "sysContact": null, "version": null, "hardware": null, "features": null, "os": "arista_eos", "type": "network", "serial": null, "icon": "arista.svg", "location": null } ] }, "poller": { "devices": [ { "sysName": "", "sysObjectID": ".1.3.6.1.4.1.30065.1.3011.7050.1958.128", "sysDescr": "Arista Networks EOS version 4.15.3F running on an Arista Networks DCS-7050TX-128", "sysContact": "", "version": "4.15.3F", "hardware": "DCS-7050TX-128", "features": null, "os": "arista_eos", "type": "network", "serial": null, "icon": "arista.svg", "location": "" } ] } }, "sensors": { "discovery": { "sensors": [ { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100301211", "sensor_index": "100301211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet1", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.03345, "sensor_limit": 0.11, "sensor_limit_warn": 0.1, "sensor_limit_low": 0.001, "sensor_limit_low_warn": 0.001, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100301211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100302211", "sensor_index": "100302211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet2", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.0182, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100302211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100303211", "sensor_index": "100303211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet3", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.02265, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100303211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100304211", "sensor_index": "100304211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet4", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.0225, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100304211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100305211", "sensor_index": "100305211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet5", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.02225, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100305211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100306211", "sensor_index": "100306211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet6", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.01915, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100306211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100307211", "sensor_index": "100307211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet7", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.02, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100307211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100308211", "sensor_index": "100308211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet8", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.01835, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100308211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100309211", "sensor_index": "100309211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet9", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.0206, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100309211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100310211", "sensor_index": "100310211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet10", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.024, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100310211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100311211", "sensor_index": "100311211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet11", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.0238, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100311211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100312211", "sensor_index": "100312211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet12", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.0151, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100312211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100313211", "sensor_index": "100313211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet13", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.0224, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100313211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100314211", "sensor_index": "100314211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet14", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.02395, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100314211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100315211", "sensor_index": "100315211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet15", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.0175, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100315211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100316211", "sensor_index": "100316211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet16", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.0207, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100316211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100317211", "sensor_index": "100317211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet17", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.01915, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100317211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100318211", "sensor_index": "100318211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet18", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.0145, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100318211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100319211", "sensor_index": "100319211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet19", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.0228, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100319211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100320211", "sensor_index": "100320211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet20", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.02135, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100320211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100321211", "sensor_index": "100321211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet21", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.02435, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100321211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100322211", "sensor_index": "100322211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet22", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.0296, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100322211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100323211", "sensor_index": "100323211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet23", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.02255, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100323211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100324211", "sensor_index": "100324211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet24", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.0276, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100324211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100325211", "sensor_index": "100325211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet25", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.018, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100325211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100326211", "sensor_index": "100326211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet26", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.02275, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100326211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100327211", "sensor_index": "100327211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet27", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.0306, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100327211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100328211", "sensor_index": "100328211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet28", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.026, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100328211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100329211", "sensor_index": "100329211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet29", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.018, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100329211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100330211", "sensor_index": "100330211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet30", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.02365, "sensor_limit": 0.09, "sensor_limit_warn": 0.085, "sensor_limit_low": 0, "sensor_limit_low_warn": 0, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100330211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100347211", "sensor_index": "100347211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet47", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.03678, "sensor_limit": 0.11, "sensor_limit_warn": 0.1, "sensor_limit_low": 0.001, "sensor_limit_low_warn": 0.001, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100347211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100348211", "sensor_index": "100348211", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Bias for Ethernet48", "group": null, "sensor_divisor": 100000, "sensor_multiplier": 1, "sensor_current": 0.03646, "sensor_limit": 0.11, "sensor_limit_warn": 0.1, "sensor_limit_low": 0.001, "sensor_limit_low_warn": 0.001, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100348211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100711103", "sensor_index": "100711103", "sensor_type": "entity-sensor", "sensor_descr": "Input current sensor", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 0.66, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100711103", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100711104", "sensor_index": "100711104", "sensor_type": "entity-sensor", "sensor_descr": "Output current sensor", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 10.66, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100711104", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100721103", "sensor_index": "100721103", "sensor_type": "entity-sensor", "sensor_descr": "Input current sensor", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 0.63, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100721103", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100721104", "sensor_index": "100721104", "sensor_type": "entity-sensor", "sensor_descr": "Output current sensor", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 10.34, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100721104", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100301212", "sensor_index": "100301212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet1", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -1.991, "sensor_limit": 3.5, "sensor_limit_warn": 2.5, "sensor_limit_low": -10.2, "sensor_limit_low_warn": -8.2, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100301212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100301213", "sensor_index": "100301213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet1", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -40, "sensor_limit": 3.5, "sensor_limit_warn": 2.5, "sensor_limit_low": -16.4, "sensor_limit_low_warn": -14.4, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100301213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100302212", "sensor_index": "100302212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet2", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.071, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100302212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100302213", "sensor_index": "100302213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet2", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100302213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100303212", "sensor_index": "100303212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet3", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.057, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100303212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100303213", "sensor_index": "100303213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet3", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100303213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100304212", "sensor_index": "100304212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet4", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.133, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100304212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100304213", "sensor_index": "100304213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet4", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100304213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100305212", "sensor_index": "100305212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet5", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.119, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100305212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100305213", "sensor_index": "100305213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet5", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100305213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100306212", "sensor_index": "100306212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet6", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.078, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100306212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100306213", "sensor_index": "100306213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet6", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100306213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100307212", "sensor_index": "100307212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet7", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.019, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100307212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100307213", "sensor_index": "100307213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet7", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100307213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100308212", "sensor_index": "100308212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet8", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.038, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100308212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100308213", "sensor_index": "100308213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet8", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100308213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100309212", "sensor_index": "100309212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet9", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.064, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100309212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100309213", "sensor_index": "100309213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet9", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100309213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100310212", "sensor_index": "100310212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet10", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.291, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100310212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100310213", "sensor_index": "100310213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet10", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100310213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100311212", "sensor_index": "100311212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet11", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.068, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100311212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100311213", "sensor_index": "100311213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet11", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100311213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100312212", "sensor_index": "100312212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet12", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.038, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100312212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100312213", "sensor_index": "100312213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet12", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100312213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100313212", "sensor_index": "100313212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet13", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -5.95, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100313212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100313213", "sensor_index": "100313213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet13", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100313213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100314212", "sensor_index": "100314212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet14", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.128, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100314212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100314213", "sensor_index": "100314213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet14", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100314213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100315212", "sensor_index": "100315212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet15", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.091, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100315212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100315213", "sensor_index": "100315213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet15", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100315213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100316212", "sensor_index": "100316212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet16", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -5.998, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100316212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100316213", "sensor_index": "100316213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet16", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100316213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100317212", "sensor_index": "100317212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet17", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.101, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100317212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100317213", "sensor_index": "100317213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet17", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100317213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100318212", "sensor_index": "100318212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet18", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.045, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100318212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100318213", "sensor_index": "100318213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet18", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100318213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100319212", "sensor_index": "100319212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet19", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.203, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100319212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100319213", "sensor_index": "100319213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet19", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100319213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100320212", "sensor_index": "100320212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet20", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.173, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100320212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100320213", "sensor_index": "100320213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet20", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -29.21, "sensor_limit_low_warn": -27.21, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100320213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100321212", "sensor_index": "100321212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet21", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.026, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100321212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100321213", "sensor_index": "100321213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet21", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -27.96, "sensor_limit_low_warn": -26.02, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100321213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100322212", "sensor_index": "100322212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet22", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.174, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100322212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100322213", "sensor_index": "100322213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet22", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -27.96, "sensor_limit_low_warn": -26.02, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100322213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100323212", "sensor_index": "100323212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet23", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -5.938, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100323212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100323213", "sensor_index": "100323213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet23", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -27.96, "sensor_limit_low_warn": -26.02, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100323213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100324212", "sensor_index": "100324212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet24", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.254, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100324212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100324213", "sensor_index": "100324213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet24", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -27.96, "sensor_limit_low_warn": -26.02, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100324213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100325212", "sensor_index": "100325212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet25", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.207, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100325212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100325213", "sensor_index": "100325213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet25", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -27.96, "sensor_limit_low_warn": -26.02, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100325213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100326212", "sensor_index": "100326212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet26", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.085, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100326212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100326213", "sensor_index": "100326213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet26", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -27.96, "sensor_limit_low_warn": -26.02, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100326213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100327212", "sensor_index": "100327212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet27", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.114, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100327212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100327213", "sensor_index": "100327213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet27", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -27.96, "sensor_limit_low_warn": -26.02, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100327213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100328212", "sensor_index": "100328212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet28", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.103, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100328212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100328213", "sensor_index": "100328213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet28", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -27.96, "sensor_limit_low_warn": -26.02, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100328213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100329212", "sensor_index": "100329212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet29", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.167, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100329212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100329213", "sensor_index": "100329213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet29", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -27.96, "sensor_limit_low_warn": -26.02, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100329213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100330212", "sensor_index": "100330212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet30", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -6.278, "sensor_limit": -1.5, "sensor_limit_warn": -3, "sensor_limit_low": -10.5, "sensor_limit_low_warn": -9, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100330212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100330213", "sensor_index": "100330213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet30", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": null, "sensor_limit": 1, "sensor_limit_warn": -1, "sensor_limit_low": -27.96, "sensor_limit_low_warn": -26.02, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100330213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100347212", "sensor_index": "100347212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet47", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -1.19, "sensor_limit": 3.5, "sensor_limit_warn": 2.5, "sensor_limit_low": -10.2, "sensor_limit_low_warn": -8.2, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100347212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100347213", "sensor_index": "100347213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet47", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -40, "sensor_limit": 3.5, "sensor_limit_warn": 2.5, "sensor_limit_low": -16.4, "sensor_limit_low_warn": -14.4, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100347213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100348212", "sensor_index": "100348212", "sensor_type": "entity-sensor", "sensor_descr": "DOM TX Power for Ethernet48", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -1.558, "sensor_limit": 3.5, "sensor_limit_warn": 2.5, "sensor_limit_low": -10.2, "sensor_limit_low_warn": -8.2, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100348212", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100348213", "sensor_index": "100348213", "sensor_type": "entity-sensor", "sensor_descr": "DOM RX Power for Ethernet48", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -40, "sensor_limit": 3.5, "sensor_limit_warn": 2.5, "sensor_limit_low": -16.4, "sensor_limit_low_warn": -14.4, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100348213", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "fanspeed", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100601111", "sensor_index": "100601111", "sensor_type": "entity-sensor", "sensor_descr": "Fan Tray 1 Fan 1 1", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 8426, "sensor_limit": 15166.800000000001, "sensor_limit_warn": null, "sensor_limit_low": 6740.8, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100601111", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "fanspeed", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100602111", "sensor_index": "100602111", "sensor_type": "entity-sensor", "sensor_descr": "Fan Tray 2 Fan 1 1", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 8287, "sensor_limit": 14916.6, "sensor_limit_warn": null, "sensor_limit_low": 6629.6, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100602111", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "fanspeed", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100603111", "sensor_index": "100603111", "sensor_type": "entity-sensor", "sensor_descr": "Fan Tray 3 Fan 1 1", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 8450, "sensor_limit": 15210, "sensor_limit_warn": null, "sensor_limit_low": 6760, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100603111", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "fanspeed", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100604111", "sensor_index": "100604111", "sensor_type": "entity-sensor", "sensor_descr": "Fan Tray 4 Fan 1 1", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 8310, "sensor_limit": 14958, "sensor_limit_warn": null, "sensor_limit_low": 6648, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100604111", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "fanspeed", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100711211", "sensor_index": "100711211", "sensor_type": "entity-sensor", "sensor_descr": "PowerSupply1 Fan 1 1", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 7968, "sensor_limit": 14342.4, "sensor_limit_warn": null, "sensor_limit_low": 6374.4, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100711211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "fanspeed", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100721211", "sensor_index": "100721211", "sensor_type": "entity-sensor", "sensor_descr": "PowerSupply2 Fan 1 1", "group": null, "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 8304, "sensor_limit": 14947.2, "sensor_limit_warn": null, "sensor_limit_low": 6643.2, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100721211", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006001", "sensor_index": "100006001", "sensor_type": "entity-sensor", "sensor_descr": "Cpu temp sensor", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 53.3, "sensor_limit": 95, "sensor_limit_warn": 90, "sensor_limit_low": 43.3, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006001", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006014", "sensor_index": "100006014", "sensor_type": "entity-sensor", "sensor_descr": "CPU board temp sensor", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 42, "sensor_limit": 80, "sensor_limit_warn": 75, "sensor_limit_low": 32, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006014", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006015", "sensor_index": "100006015", "sensor_type": "entity-sensor", "sensor_descr": "Back-panel temp sensor", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 36.5, "sensor_limit": 85, "sensor_limit_warn": 75, "sensor_limit_low": 26.5, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006015", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006016", "sensor_index": "100006016", "sensor_type": "entity-sensor", "sensor_descr": "Front-panel temp sensor", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 24.6, "sensor_limit": 70, "sensor_limit_warn": 65, "sensor_limit_low": 14.6, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006016", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006017", "sensor_index": "100006017", "sensor_type": "entity-sensor", "sensor_descr": "Jericho0 ambient temp sensor", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 43, "sensor_limit": 90, "sensor_limit_warn": 75, "sensor_limit_low": 33, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006017", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006018", "sensor_index": "100006018", "sensor_type": "entity-sensor", "sensor_descr": "Jericho0 on-die temp sensor", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 64.8, "sensor_limit": 110, "sensor_limit_warn": 100, "sensor_limit_low": 54.8, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006018", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006019", "sensor_index": "100006019", "sensor_type": "entity-sensor", "sensor_descr": "Jericho1 ambient temp sensor", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 52, "sensor_limit": 90, "sensor_limit_warn": 75, "sensor_limit_low": 42, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006019", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006020", "sensor_index": "100006020", "sensor_type": "entity-sensor", "sensor_descr": "Jericho1 on-die temp sensor", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 64, "sensor_limit": 110, "sensor_limit_warn": 100, "sensor_limit_low": 54, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006020", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100301201", "sensor_index": "100301201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet1", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 25.8, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100301201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100302201", "sensor_index": "100302201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet2", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 33.7, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100302201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100303201", "sensor_index": "100303201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet3", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 35.8, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100303201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100304201", "sensor_index": "100304201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet4", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 37.9, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100304201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100305201", "sensor_index": "100305201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet5", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 36.5, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100305201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100306201", "sensor_index": "100306201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet6", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 36.5, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100306201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100307201", "sensor_index": "100307201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet7", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 34.8, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100307201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100308201", "sensor_index": "100308201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet8", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 36.9, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100308201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100309201", "sensor_index": "100309201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet9", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 35.1, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100309201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100310201", "sensor_index": "100310201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet10", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 39.3, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100310201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100311201", "sensor_index": "100311201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet11", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 36.5, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100311201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100312201", "sensor_index": "100312201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet12", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 34.4, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100312201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100313201", "sensor_index": "100313201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet13", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 36.2, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100313201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100314201", "sensor_index": "100314201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet14", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 39.3, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100314201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100315201", "sensor_index": "100315201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet15", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 34.4, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100315201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100316201", "sensor_index": "100316201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet16", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 38.3, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100316201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100317201", "sensor_index": "100317201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet17", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 34.8, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100317201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100318201", "sensor_index": "100318201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet18", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 33, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100318201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100319201", "sensor_index": "100319201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet19", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 36.5, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100319201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100320201", "sensor_index": "100320201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet20", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 38.3, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100320201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100321201", "sensor_index": "100321201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet21", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 33.4, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100321201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100322201", "sensor_index": "100322201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet22", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 37.9, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100322201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100323201", "sensor_index": "100323201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet23", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 32, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100323201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100324201", "sensor_index": "100324201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet24", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 36.5, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100324201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100325201", "sensor_index": "100325201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet25", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 29.9, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100325201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100326201", "sensor_index": "100326201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet26", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 36.5, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100326201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100327201", "sensor_index": "100327201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet27", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 37.9, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100327201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100328201", "sensor_index": "100328201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet28", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 37.6, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100328201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100329201", "sensor_index": "100329201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet29", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 30.9, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100329201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100330201", "sensor_index": "100330201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet30", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 34.4, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100330201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100347201", "sensor_index": "100347201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet47", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 25.4, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100347201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100348201", "sensor_index": "100348201", "sensor_type": "entity-sensor", "sensor_descr": "DOM Temperature for Ethernet48", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 24.8, "sensor_limit": 100, "sensor_limit_warn": 85, "sensor_limit_low": -50, "sensor_limit_low_warn": -40, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100348201", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100711101", "sensor_index": "100711101", "sensor_type": "entity-sensor", "sensor_descr": "Hotspot temperature sensor", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 47, "sensor_limit": 100, "sensor_limit_warn": 95, "sensor_limit_low": 37, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100711101", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100711102", "sensor_index": "100711102", "sensor_type": "entity-sensor", "sensor_descr": "Inlet temperature sensor", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 36, "sensor_limit": 75, "sensor_limit_warn": 70, "sensor_limit_low": 26, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100711102", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100721101", "sensor_index": "100721101", "sensor_type": "entity-sensor", "sensor_descr": "Hotspot temperature sensor", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 48, "sensor_limit": 100, "sensor_limit_warn": 95, "sensor_limit_low": 38, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100721101", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100721102", "sensor_index": "100721102", "sensor_type": "entity-sensor", "sensor_descr": "Inlet temperature sensor", "group": null, "sensor_divisor": 10, "sensor_multiplier": 1, "sensor_current": 38, "sensor_limit": 75, "sensor_limit_warn": 70, "sensor_limit_low": 28, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100721102", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006002", "sensor_index": "100006002", "sensor_type": "entity-sensor", "sensor_descr": "CpucardPwrCon Rail1 12V standby", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 11.98, "sensor_limit": 13.777, "sensor_limit_warn": null, "sensor_limit_low": 10.183, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006002", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006003", "sensor_index": "100006003", "sensor_type": "entity-sensor", "sensor_descr": "CpucardPwrCon Rail2 5V", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 5.05, "sensor_limit": 5.8075, "sensor_limit_warn": null, "sensor_limit_low": 4.2925, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006003", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006004", "sensor_index": "100006004", "sensor_type": "entity-sensor", "sensor_descr": "CpucardPwrCon Rail3 3V3", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.3, "sensor_limit": 3.795, "sensor_limit_warn": null, "sensor_limit_low": 2.805, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006004", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006005", "sensor_index": "100006005", "sensor_type": "entity-sensor", "sensor_descr": "CpucardPwrCon Rail4 1V8", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 1.8, "sensor_limit": 2.07, "sensor_limit_warn": null, "sensor_limit_low": 1.53, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006005", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006006", "sensor_index": "100006006", "sensor_type": "entity-sensor", "sensor_descr": "CpucardPwrCon Rail5 1V5", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 1.5, "sensor_limit": 1.725, "sensor_limit_warn": null, "sensor_limit_low": 1.275, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006006", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006007", "sensor_index": "100006007", "sensor_type": "entity-sensor", "sensor_descr": "CpucardPwrCon Rail6 1V5", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 1.49, "sensor_limit": 1.7135, "sensor_limit_warn": null, "sensor_limit_low": 1.2665, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006007", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006008", "sensor_index": "100006008", "sensor_type": "entity-sensor", "sensor_descr": "CpucardPwrCon Rail7 0V75", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 0.75, "sensor_limit": 0.8625, "sensor_limit_warn": null, "sensor_limit_low": 0.6375, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006008", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006009", "sensor_index": "100006009", "sensor_type": "entity-sensor", "sensor_descr": "CpucardPwrCon Rail8 0V95", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 0.94, "sensor_limit": 1.081, "sensor_limit_warn": null, "sensor_limit_low": 0.799, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006009", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006010", "sensor_index": "100006010", "sensor_type": "entity-sensor", "sensor_descr": "CpucardPwrCon Rail9 1V8", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 1.8, "sensor_limit": 2.07, "sensor_limit_warn": null, "sensor_limit_low": 1.53, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006010", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006011", "sensor_index": "100006011", "sensor_type": "entity-sensor", "sensor_descr": "CpucardPwrCon Rail10 3V3", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.3, "sensor_limit": 3.795, "sensor_limit_warn": null, "sensor_limit_low": 2.805, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006011", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006012", "sensor_index": "100006012", "sensor_type": "entity-sensor", "sensor_descr": "CpucardPwrCon Rail11 0V95", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 0.94, "sensor_limit": 1.081, "sensor_limit_warn": null, "sensor_limit_low": 0.799, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006012", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006013", "sensor_index": "100006013", "sensor_type": "entity-sensor", "sensor_descr": "CpucardPwrCon Rail12 1V2", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 1.22, "sensor_limit": 1.403, "sensor_limit_warn": null, "sensor_limit_low": 1.037, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006013", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006021", "sensor_index": "100006021", "sensor_type": "entity-sensor", "sensor_descr": "PwrCon1 Rail1 POS1V0_JE0", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 1.04, "sensor_limit": 1.196, "sensor_limit_warn": null, "sensor_limit_low": 0.884, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006021", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006022", "sensor_index": "100006022", "sensor_type": "entity-sensor", "sensor_descr": "PwrCon1 Rail2 POS1V0_JE1", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 1.04, "sensor_limit": 1.196, "sensor_limit_warn": null, "sensor_limit_low": 0.884, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006022", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006023", "sensor_index": "100006023", "sensor_type": "entity-sensor", "sensor_descr": "PwrCon1 Rail3 POS1V0A_JE01", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 1, "sensor_limit": 1.15, "sensor_limit_warn": null, "sensor_limit_low": 0.85, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006023", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006024", "sensor_index": "100006024", "sensor_type": "entity-sensor", "sensor_descr": "PwrCon1 Rail7 POS1V2", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 1.2, "sensor_limit": 1.38, "sensor_limit_warn": null, "sensor_limit_low": 1.02, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006024", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006025", "sensor_index": "100006025", "sensor_type": "entity-sensor", "sensor_descr": "PwrCon1 Rail8 POS1V25", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 1.25, "sensor_limit": 1.4375, "sensor_limit_warn": null, "sensor_limit_low": 1.0625, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006025", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006026", "sensor_index": "100006026", "sensor_type": "entity-sensor", "sensor_descr": "PwrCon1 Rail9 POS1V35_JE0", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 1.35, "sensor_limit": 1.5525, "sensor_limit_warn": null, "sensor_limit_low": 1.1475, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006026", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006027", "sensor_index": "100006027", "sensor_type": "entity-sensor", "sensor_descr": "PwrCon1 Rail10 POS1V35_JE1", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 1.35, "sensor_limit": 1.5525, "sensor_limit_warn": null, "sensor_limit_low": 1.1475, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006027", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006028", "sensor_index": "100006028", "sensor_type": "entity-sensor", "sensor_descr": "PwrCon1 Rail11 POS1V8", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 1.8, "sensor_limit": 2.07, "sensor_limit_warn": null, "sensor_limit_low": 1.53, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006028", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006029", "sensor_index": "100006029", "sensor_type": "entity-sensor", "sensor_descr": "PwrCon1 Rail12 POS2V5", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 2.5, "sensor_limit": 2.875, "sensor_limit_warn": null, "sensor_limit_low": 2.125, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006029", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006030", "sensor_index": "100006030", "sensor_type": "entity-sensor", "sensor_descr": "PwrCon1 Rail13 POS3V3", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.3, "sensor_limit": 3.795, "sensor_limit_warn": null, "sensor_limit_low": 2.805, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006030", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006031", "sensor_index": "100006031", "sensor_type": "entity-sensor", "sensor_descr": "PwrCon1 Rail14 POS3V3_SFP", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.28, "sensor_limit": 3.772, "sensor_limit_warn": null, "sensor_limit_low": 2.788, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006031", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006032", "sensor_index": "100006032", "sensor_type": "entity-sensor", "sensor_descr": "PwrCon1 Rail15 POS12V_STDBY", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 11.87, "sensor_limit": 13.6505, "sensor_limit_warn": null, "sensor_limit_low": 10.0895, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006032", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100006033", "sensor_index": "100006033", "sensor_type": "entity-sensor", "sensor_descr": "PwrCon1 Rail16 POS12V", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 11.99, "sensor_limit": 13.7885, "sensor_limit_warn": null, "sensor_limit_low": 10.1915, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100006033", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100301202", "sensor_index": "100301202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet1", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.31, "sensor_limit": 3.63, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.97, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100301202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100302202", "sensor_index": "100302202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet2", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.34, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100302202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100303202", "sensor_index": "100303202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet3", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.33, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100303202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100304202", "sensor_index": "100304202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet4", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.34, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100304202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100305202", "sensor_index": "100305202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet5", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.34, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100305202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100306202", "sensor_index": "100306202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet6", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.34, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100306202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100307202", "sensor_index": "100307202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet7", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.33, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100307202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100308202", "sensor_index": "100308202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet8", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.34, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100308202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100309202", "sensor_index": "100309202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet9", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.34, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100309202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100310202", "sensor_index": "100310202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet10", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.33, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100310202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100311202", "sensor_index": "100311202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet11", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.33, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100311202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100312202", "sensor_index": "100312202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet12", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.33, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100312202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100313202", "sensor_index": "100313202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet13", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.33, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100313202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100314202", "sensor_index": "100314202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet14", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.33, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100314202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100315202", "sensor_index": "100315202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet15", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.33, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100315202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100316202", "sensor_index": "100316202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet16", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.33, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100316202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100317202", "sensor_index": "100317202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet17", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.34, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100317202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100318202", "sensor_index": "100318202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet18", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.34, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100318202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100319202", "sensor_index": "100319202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet19", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.33, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100319202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100320202", "sensor_index": "100320202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet20", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.34, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100320202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100321202", "sensor_index": "100321202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet21", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.34, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100321202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100322202", "sensor_index": "100322202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet22", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.34, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100322202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100323202", "sensor_index": "100323202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet23", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.33, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100323202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100324202", "sensor_index": "100324202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet24", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.36, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100324202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100325202", "sensor_index": "100325202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet25", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.35, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100325202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100326202", "sensor_index": "100326202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet26", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.34, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100326202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100327202", "sensor_index": "100327202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet27", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.32, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100327202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100328202", "sensor_index": "100328202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet28", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.33, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100328202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100329202", "sensor_index": "100329202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet29", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.34, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100329202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100330202", "sensor_index": "100330202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet30", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.35, "sensor_limit": 3.8, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.81, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100330202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100347202", "sensor_index": "100347202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet47", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.32, "sensor_limit": 3.63, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.97, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100347202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100348202", "sensor_index": "100348202", "sensor_type": "entity-sensor", "sensor_descr": "DOM Voltage for Ethernet48", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 3.32, "sensor_limit": 3.63, "sensor_limit_warn": 3.47, "sensor_limit_low": 2.97, "sensor_limit_low_warn": 3.14, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100348202", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100711105", "sensor_index": "100711105", "sensor_type": "entity-sensor", "sensor_descr": "Input voltage sensor", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 229.25, "sensor_limit": 263.6375, "sensor_limit_warn": null, "sensor_limit_low": 194.8625, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100711105", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100711106", "sensor_index": "100711106", "sensor_type": "entity-sensor", "sensor_descr": "Output voltage sensor", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 11.97, "sensor_limit": 13.7655, "sensor_limit_warn": null, "sensor_limit_low": 10.1745, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100711106", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100721105", "sensor_index": "100721105", "sensor_type": "entity-sensor", "sensor_descr": "Input voltage sensor", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 230.25, "sensor_limit": 264.7875, "sensor_limit_warn": null, "sensor_limit_low": 195.7125, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100721105", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.2.1.99.1.1.1.4.100721106", "sensor_index": "100721106", "sensor_type": "entity-sensor", "sensor_descr": "Output voltage sensor", "group": null, "sensor_divisor": 100, "sensor_multiplier": 1, "sensor_current": 12, "sensor_limit": 13.8, "sensor_limit_warn": null, "sensor_limit_low": 10.2, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "100721106", "entPhysicalIndex_measured": null, "sensor_prev": null, "user_func": null, "state_name": null } ], "state_indexes": [] }, "poller": "matches discovery" }, "bgp-peers": { "discovery": { "bgpPeers": [ { "astext": "", "bgpPeerIdentifier": "192.168.0.2", "bgpPeerRemoteAs": 65000, "bgpPeerState": "idle", "bgpPeerAdminStatus": "stop", "bgpLocalAddr": "0.0.0.0", "bgpPeerRemoteAddr": "0.0.0.0", "bgpPeerDescr": "", "bgpPeerInUpdates": 0, "bgpPeerOutUpdates": 0, "bgpPeerInTotalMessages": 0, "bgpPeerOutTotalMessages": 0, "bgpPeerFsmEstablishedTime": 0, "bgpPeerInUpdateElapsedTime": 0, "context_name": "", "bgpLocalAs": 65000, "vrfLocalAs": null, "bgpPeerLastErrorCode": null, "bgpPeerLastErrorSubCode": null, "bgpPeerLastErrorText": null }, { "astext": "", "bgpPeerIdentifier": "2001:0550:0002:002f:0000:0000:0033:0001", "bgpPeerRemoteAs": 65001, "bgpPeerState": "idle", "bgpPeerAdminStatus": "stop", "bgpLocalAddr": "0.0.0.0", "bgpPeerRemoteAddr": "0.0.0.0", "bgpPeerDescr": "", "bgpPeerInUpdates": 0, "bgpPeerOutUpdates": 0, "bgpPeerInTotalMessages": 0, "bgpPeerOutTotalMessages": 0, "bgpPeerFsmEstablishedTime": 0, "bgpPeerInUpdateElapsedTime": 0, "context_name": "", "bgpLocalAs": 65000, "vrfLocalAs": null, "bgpPeerLastErrorCode": null, "bgpPeerLastErrorSubCode": null, "bgpPeerLastErrorText": null } ], "bgpPeers_cbgp": [ { "bgpPeerIdentifier": "192.168.0.2", "afi": "ipv4", "safi": "unicast", "AcceptedPrefixes": 0, "DeniedPrefixes": 0, "PrefixAdminLimit": 0, "PrefixThreshold": 0, "PrefixClearThreshold": 0, "AdvertisedPrefixes": 0, "SuppressedPrefixes": 0, "WithdrawnPrefixes": 0, "AcceptedPrefixes_delta": 0, "AcceptedPrefixes_prev": 0, "DeniedPrefixes_delta": 0, "DeniedPrefixes_prev": 0, "AdvertisedPrefixes_delta": 0, "AdvertisedPrefixes_prev": 0, "SuppressedPrefixes_delta": 0, "SuppressedPrefixes_prev": 0, "WithdrawnPrefixes_delta": 0, "WithdrawnPrefixes_prev": 0, "context_name": "" }, { "bgpPeerIdentifier": "2001:0550:0002:002f:0000:0000:0033:0001", "afi": "ipv6", "safi": "unicast", "AcceptedPrefixes": 0, "DeniedPrefixes": 0, "PrefixAdminLimit": 0, "PrefixThreshold": 0, "PrefixClearThreshold": 0, "AdvertisedPrefixes": 0, "SuppressedPrefixes": 0, "WithdrawnPrefixes": 0, "AcceptedPrefixes_delta": 0, "AcceptedPrefixes_prev": 0, "DeniedPrefixes_delta": 0, "DeniedPrefixes_prev": 0, "AdvertisedPrefixes_delta": 0, "AdvertisedPrefixes_prev": 0, "SuppressedPrefixes_delta": 0, "SuppressedPrefixes_prev": 0, "WithdrawnPrefixes_delta": 0, "WithdrawnPrefixes_prev": 0, "context_name": "" } ] }, "poller": { "bgpPeers": [ { "astext": "", "bgpPeerIdentifier": "192.168.0.2", "bgpPeerRemoteAs": 65000, "bgpPeerState": "established", "bgpPeerAdminStatus": "running", "bgpLocalAddr": "192.168.0.1", "bgpPeerRemoteAddr": "0.0.0.0", "bgpPeerDescr": "peer.example.com EBGP", "bgpPeerInUpdates": 13362513, "bgpPeerOutUpdates": 13579799, "bgpPeerInTotalMessages": 13579799, "bgpPeerOutTotalMessages": 17644316, "bgpPeerFsmEstablishedTime": 13090321, "bgpPeerInUpdateElapsedTime": 4, "context_name": "", "bgpLocalAs": 65000, "vrfLocalAs": null, "bgpPeerLastErrorCode": 0, "bgpPeerLastErrorSubCode": 0, "bgpPeerLastErrorText": "Cease/administrative shutdown" }, { "astext": "", "bgpPeerIdentifier": "2001:0550:0002:002f:0000:0000:0033:0001", "bgpPeerRemoteAs": 65001, "bgpPeerState": "established", "bgpPeerAdminStatus": "running", "bgpLocalAddr": "2001:0550:0002:002f:0000:0000:0033:0002", "bgpPeerRemoteAddr": "0.0.0.0", "bgpPeerDescr": "", "bgpPeerInUpdates": 12658044, "bgpPeerOutUpdates": 118, "bgpPeerInTotalMessages": 12658183, "bgpPeerOutTotalMessages": 447455, "bgpPeerFsmEstablishedTime": 1551697, "bgpPeerInUpdateElapsedTime": 17, "context_name": "", "bgpLocalAs": 65000, "vrfLocalAs": null, "bgpPeerLastErrorCode": null, "bgpPeerLastErrorSubCode": null, "bgpPeerLastErrorText": null } ], "bgpPeers_cbgp": [ { "bgpPeerIdentifier": "192.168.0.2", "afi": "ipv4", "safi": "unicast", "AcceptedPrefixes": 540339, "DeniedPrefixes": 0, "PrefixAdminLimit": 0, "PrefixThreshold": 0, "PrefixClearThreshold": 0, "AdvertisedPrefixes": 0, "SuppressedPrefixes": 0, "WithdrawnPrefixes": 0, "AcceptedPrefixes_delta": 540339, "AcceptedPrefixes_prev": 0, "DeniedPrefixes_delta": 0, "DeniedPrefixes_prev": 0, "AdvertisedPrefixes_delta": 0, "AdvertisedPrefixes_prev": 0, "SuppressedPrefixes_delta": 0, "SuppressedPrefixes_prev": 0, "WithdrawnPrefixes_delta": 0, "WithdrawnPrefixes_prev": 0, "context_name": "" }, { "bgpPeerIdentifier": "2001:0550:0002:002f:0000:0000:0033:0001", "afi": "ipv6", "safi": "unicast", "AcceptedPrefixes": 40633, "DeniedPrefixes": 0, "PrefixAdminLimit": 0, "PrefixThreshold": 0, "PrefixClearThreshold": 0, "AdvertisedPrefixes": 0, "SuppressedPrefixes": 0, "WithdrawnPrefixes": 0, "AcceptedPrefixes_delta": 40633, "AcceptedPrefixes_prev": 0, "DeniedPrefixes_delta": 0, "DeniedPrefixes_prev": 0, "AdvertisedPrefixes_delta": 0, "AdvertisedPrefixes_prev": 0, "SuppressedPrefixes_delta": 0, "SuppressedPrefixes_prev": 0, "WithdrawnPrefixes_delta": 0, "WithdrawnPrefixes_prev": 0, "context_name": "" } ] } } }