-- ***************************************************************** -- NCB-8610 Private MIB -- -- Sept. 2006, Greg Lin -- -- Copyright (c) 2006 by Senao Technology Co., Ltd. -- All rights reserved. -- -- Note: This MIB file is modification 3220 private MIB. -- It modify SNMPv2 to SNMPv1 syntax. -- -- Date: 2006-09-20 -- ***************************************************************** --SENAO-NCB8610-MIB { iso(1) org(3) dod(6) internet(1) private(4) Enterprises(1) Senao(14125) } --module definition SENAO-WLAN-CB-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, IpAddress FROM RFC1155-SMI DisplayString, PhysAddress FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 mgmt, NetworkAddress, IpAddress, Counter, Gauge, TimeTicks FROM RFC1155-SMI; -- SENAO-Private-MIB DEFINITIONS -- senaoMIB OBJECT IDENTIFIER ::= { enterprises 14125 } -- SENAO-RFC1213-MIB DEFINITIONS -- senaoRFC1213Group OBJECT IDENTIFIER ::= { senaoMIB 1 } -- SENAO-Private-MIB DEFINITIONS -- statusInformationGroup OBJECT IDENTIFIER ::= { senaoMIB 2 } countersGroup OBJECT IDENTIFIER ::= { senaoMIB 3 } privacySettingsGroup OBJECT IDENTIFIER ::= { senaoMIB 4 } systemSettingsGroup OBJECT IDENTIFIER ::= { senaoMIB 5 } webAdministratorSettingsGroup OBJECT IDENTIFIER ::= { senaoMIB 6 } -- SENAO-RFC1213-MIB DEFINITIONS -- ip OBJECT IDENTIFIER ::= { senaoRFC1213Group 1 } icmp OBJECT IDENTIFIER ::= { senaoRFC1213Group 2 } tcp OBJECT IDENTIFIER ::= { senaoRFC1213Group 3 } udp OBJECT IDENTIFIER ::= { senaoRFC1213Group 4 } -- SENAO-Private-MIB DEFINITIONS -- -- [ statusInformationGroup ] [1] -- connectedToSSID OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This attribute reflects the Service Set ID. This value may be modified by an external management entity and used by the local SME to make decisions about the Scanning process. The connectedToSSID length is limit between 1~ 32 characters. @GET-FUNC=get_statusInfo_group @SET-FUNC=set_statusInfo_group" ::= { statusInformationGroup 1 } usingChannel OBJECT-TYPE SYNTAX INTEGER { -- Note: the SNMPv1 does not support channel array so chang channelX channel1 (1), channel2 (2), channel3 (3), channel4 (4), channel5 (5), channel6 (6), channel7 (7), channel8 (8), channel9 (9), channel10 (10), channel11 (11) } ACCESS read-only STATUS mandatory DESCRIPTION "The operating frequency channel. Valid numbers are as defind in ISO/IEC 8802-11:1999, 15.4.6.2. @GET-FUNC=get_statusInfo_group" ::= { statusInformationGroup 2 } -- (CB) clientBridgeMACAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The purpose of clientBridgeMACAddress is to allow a manager to identify a station for its own purposes. This attribute provides for that eventuality while keeping the true MAC address independent. Its syntax is MAC address and default value is the station's assigned, unique MAC address. @GET-FUNC=get_statusInfo_group" ::= { statusInformationGroup 3 } currentIPAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address of this device used over its Ethernet interface in Routing mode or Bridge interface in Bridgeing mode. @GET-FUNC=get_statusInfo_group" ::= { statusInformationGroup 4 } -- (CB) linkUpIndicator OBJECT-TYPE SYNTAX INTEGER -- Error: number enumeration contains zero value in SMIv1 MIB --{ -- offLine(0), -- onLine(1) --} ACCESS read-only STATUS mandatory DESCRIPTION "The operated state of the wireless interface. The onLine(1) state indicates that this device connected to Access Point. @GET-FUNC=get_statusInfo_group" ::= { statusInformationGroup 5 } clientSignalStrength OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "A device-dependent measure of the signal strength(%) of the most recently received packet from this Station. @GET-FUNC=get_statusInfo_group" ::= { statusInformationGroup 6 } clientAssociationTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time since this device connected to Access Point. @GET-FUNC=get_statusInfo_group" ::= { statusInformationGroup 7 } currentTXPower OBJECT-TYPE SYNTAX INTEGER { -- Transmit Power Level high (1), medium (2), low (3) } ACCESS read-write STATUS mandatory DESCRIPTION "The Transmit Power of this device used. @GET-FUNC=get_statusInfo_group @SET-FUNC=set_statusInfo_group" ::= { statusInformationGroup 8 } -- [ countersGroup ] [2] -- receivedPacketsGoodCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of good packets received on the radio interface, including unicast, broadcast and multicast packets. @GET-FUNC=get_counters_group" ::= { countersGroup 1 } receivedPacketsBadCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of inbound bad packets of the radio interface were chosen to be discarded even though no errors had been detected to prevent their being received. One possible reason for discarding such a packet could be to free up buffer space. Another reason would be exceeding their maximum time-to-live. @GET-FUNC=get_counters_group" ::= { countersGroup 2 } sendPacketsGoodCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of good packets transmitted on the radio interface, including unicast, broadcast and multicast packets. @GET-FUNC=get_counters_group" ::= { countersGroup 3 } sendPacketsBadCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of outbound bad packets of the radio interface were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet could be to free up buffer space. Another reason would be exceeding their maximum time-to-live. @GET-FUNC=get_counters_group" ::= { countersGroup 4 } -- [ privacySettingsGroup ] [3] -- wepEnabled OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this attribute is enable, it shall indicate that the IEEE 802.11 WEP mechanism is used for transmitting frames of type Data. The default value of this attribute shall be disable. @GET-FUNC=get_privacy_group @SET-FUNC=set_privacy_group" ::= { privacySettingsGroup 1 } wepKeyLength OBJECT-TYPE SYNTAX INTEGER { key-64bits(1), key-128bits(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The length of WEP key that is used for transmitting and received frames of type Data. The value of 0 denotes WEP64bit Hex. Key; 1 stands for WEP128bit Hex. Key @GET-FUNC=get_privacy_group @SET-FUNC=set_privacy_group" ::= { privacySettingsGroup 2 } wepKeyNumber OBJECT-TYPE SYNTAX INTEGER { wep-key1(1), wep-key2(2), wep-key3(3), wep-key4(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute shall indicate the use of the first, second, third, or fourth element of the WEPDefaultKeys array when set to values of 1, 2, 3, or 4. The default value of this attribute shall be 0. @GET-FUNC=get_privacy_group @SET-FUNC=set_privacy_group" -- REFERENCE "IEEE Std 802.11-1997, 8.3.2" ::= { privacySettingsGroup 3 } wepKey OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A WEP secret key value. 10 Hex. Keys for WEP 64Bits/26 Hex. Keys for WEP128Bits. @GET-FUNC=get_privacy_group @SET-FUNC=set_privacy_group" ::= { privacySettingsGroup 4 } -- [ systemSettingsGroup ] [4] -- operationMode OBJECT-TYPE SYNTAX INTEGER { bridge(1), ap-wds(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This defines the type of role of a wireless device. The device types are: Bridge(1) -- Bridge AP+WDS(2) -- Access Point+WDS @GET-FUNC=get_system_group" ::= { systemSettingsGroup 1 } ipAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of this device used over its Ethernet interface in CB mode. The IP address must NOT set [x.x.x.0] or [x,x.x.255]. @GET-FUNC=get_system_group @SET-FUNC=set_system_group" ::= { systemSettingsGroup 2 } subnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP Network mask used by the IP entity when accessing devices through any of its Ethernet interface in Routing mode or Bridge interface in Bridgeing mode. The value of subnet mask must set to 0, 128, 192, 224, 240, 248, 252, 254, 255. @GET-FUNC=get_system_group @SET-FUNC=set_system_group" ::= { systemSettingsGroup 3 } ipGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address of this device's Gateway. The value of IP Gateway must NOT set to 0 or 255 @GET-FUNC=get_system_group @SET-FUNC=set_system_group" ::= { systemSettingsGroup 4 } deviceName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The description name of this device. The deviceName length is limit between 1~32 characters. @GET-FUNC=get_system_group @SET-FUNC=set_system_group" ::= { systemSettingsGroup 5 } -- desiredSSID OBJECT-TYPE -- SYNTAX OCTET STRING -- ACCESS read-write -- STATUS mandatory -- DESCRIPTION -- "The Preferred Service Set ID used in the most recent MLME_Scan.request. -- This value may be modified by an external management entity and used by -- the local SME to make decisions about the Scanning process. -- @GET-FUNC=get_system_group -- @SET-FUNC=set_system_group" -- ::= { systemSettingsGroup 6 } saveReboot OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Save and Reboot System The save Reboot value must set to 1 when you enable this function. @GET-FUNC=get_system_group @SET-FUNC=set_system_group" ::= { systemSettingsGroup 6 } -- [ webAdministratorSettingsGroup ] [5] -- userName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User Name assigned to the system for use when authenticating with Web browser. The username length limit is 15 characters. @GET-FUNC=get_webAdmin_group @SET-FUNC=set_webAdmin_group" ::= { webAdministratorSettingsGroup 1} password OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User Password assigned to the system for use when authenticating with Web browser. The password length limit is 15 characters. @GET-FUNC=get_webAdmin_group @SET-FUNC=set_webAdmin_group" ::= { webAdministratorSettingsGroup 2} -- SENAO-RFC1213-MIB DEFINITIONS -- -- the IP group -- Implementation of the IP group is mandatory for all -- systems. ipInReceives OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of input datagrams received from interfaces, including those received in error. @GET-FUNC=get_ip_row" ::= { ip 1 } ipForwDatagrams OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of input datagrams for which this entity was not their final IP destination, as a result of which an attempt was made to find a route to forward them to that final destination. In entities which do not act as IP Gateways, this counter will include only those packets which were Source-Routed via this entity, and the Source- Route option processing was successful. @GET-FUNC=get_ip_row" ::= { ip 2 } -- the ICMP group -- Implementation of the ICMP group is mandatory for all -- systems. icmpInMsgs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of ICMP messages which the entity received. Note that this counter includes all those counted by icmpInErrors. @GET-FUNC=get_icmp_row" ::= { icmp 1 } icmpOutMsgs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of ICMP messages which this entity attempted to send. Note that this counter includes all those counted by icmpOutErrors. @GET-FUNC=get_icmp_row" ::= { icmp 2 } -- the TCP group -- Implementation of the TCP group is mandatory for all -- systems that implement the TCP. -- Note that instances of object types that represent -- information about a particular TCP connection are -- transient; they persist only as long as the connection -- in question. tcpInSegs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of segments received, including those received in error. This count includes segments received on currently established connections. @GET-FUNC=get_tcp_row" ::= { tcp 1 } tcpOutSegs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of segments sent, including those on current connections but excluding those containing only retransmitted octets. @GET-FUNC=get_tcp_row" ::= { tcp 2 } -- the UDP group -- Implementation of the UDP group is mandatory for all -- systems which implement the UDP. udpInDatagrams OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of UDP datagrams delivered to UDP users. @GET-FUNC=get_udp_row" ::= { udp 1 } udpOutDatagrams OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of UDP datagrams sent from this entity. @GET-FUNC=get_udp_row" ::= { udp 2 } END