-- ================================================================= -- Copyright (C) 2003 by HUAWEI TECHNOLOGIES. All rights reserved. -- -- Description: Huawei Entity extent MIB File for environment -- Reference: -- Version: V1.10 -- History: -- -- 2005-04-16 V1.10 Cui Kemao(20339), Added replaceable unit Information -- 2003-07-28 V1.00 Chen baojiang & Ma ye, Initial Version -- ================================================================= HUAWEI-ENTITY-EXTENT-MIB DEFINITIONS ::= BEGIN IMPORTS entPhysicalIndex FROM ENTITY-MIB hwDatacomm FROM HUAWEI-MIB SnmpAdminString FROM SNMP-FRAMEWORK-MIB OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP FROM SNMPv2-CONF Integer32, BITS, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI DateAndTime, TEXTUAL-CONVENTION, RowStatus, DisplayString FROM SNMPv2-TC EnabledStatus FROM P-BRIDGE-MIB InterfaceIndex FROM IF-MIB; hwEntityExtentMIB MODULE-IDENTITY LAST-UPDATED "200606290000Z" -- June 29, 2006 at 00:00 GMT ORGANIZATION "Huawei Technologies co.,Ltd." CONTACT-INFO " R&D BeiJing, Huawei Technologies co.,Ltd. Huawei Bld.,NO.3 Xinxi Rd., Shang-Di Information Industry Base, Hai-Dian District Beijing P.R. China Zip:100085 Http://www.huawei.com E-mail:support@huawei.com " DESCRIPTION "The private mib file includes the general extent information of the device." ::= { hwDatacomm 31 } -- -- Textual conventions -- HwAdminState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION " Represents the various possible administrative states. A value of locked means the resource is administratively prohibited from use. A value of shuttingDown means that usage is administratively limited to current instances of use. A value of unlocked means the resource is not administratively prohibited from use. A value of up means that the port is not administratively shut down and a value of down is the oppsite. A value of loopback here means the port is working in the loopback local mode. When a port is both shut down and looped back, we user the vale of down." REFERENCE "ITU Recommendation X.731, 'Information Technology - Open Systems Interconnection - System Management: State Management Function', 1992" SYNTAX INTEGER { notSupported(1), locked(2), shuttingDown(3), unlocked(4), up(11), down(12), loopback(13) } HwOperState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION " Represents the possible values of operational states. A value of disabled means the resource is totally inoperable. A value of enabled means the resource is partially or fully operable. The values up(11),down(12) and connect(13) is used only for NE5000E BTB or it's extended system. A value of protocolUp means the port is available in the protocol lay or has already prepared for transmitting or receiving data. A value of linkUp means the port is only available in the physical lay. A value of linkDown means the port is not available physically." REFERENCE "ITU Recommendation X.731, 'Information Technology - Open Systems Interconnection - System Management: State Management Function', 1992" SYNTAX INTEGER { notSupported(1), disabled(2), enabled(3), offline(4), up(11), down(12), connect(13), protocolUp(15), linkUp(16), linkDown(17) } HWLevelState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The normal state of input line ." SYNTAX INTEGER { lowLevel(1), highLevel(2) } HwStandbyStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION " Represents the possible values of standby status. A value of hotStandby means the resource is not providing service, but is will be immediately able to take over the role of the resource to be backed-up, without the need for initialization activity, and will contain the same information as the resource to be backed up. A value of coldStandy means that the resource is to back-up another resource, but will not be immediately able to take over the role of a resource to be backed up, and will require some initialization activity. A value of providingService means the resource is providing service." REFERENCE "ITU Recommendation X.731, 'Information Technology - Open Systems Interconnection - System Management: State Management Function', 1992" SYNTAX INTEGER { notSupported(1), hotStandby(2), coldStandby(3), providingService(4) } -- Not defined in X.731 HwAlarmStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the possible values of alarm status. When no bits of this attribute are set, then none of the status conditions described below are present. When the value of under repair is set, the resource is currently being repaired. When the value of critical is set, one or more critical alarms are active against the resource. When the value of major is set, one or more major alarms are active against the resource. When the value of minor is set, one or more minor alarms are active against the resource. When the value of warning is set, one or more warning alarms are active against the resource. When the value of indeterminate is set, one or more alarms of indeterminate severity are active against the resource. When the value of alarm outstanding is set, one or more alarms is active against the resource. The fault may or may not be disabling. " REFERENCE "ITU Recommendation X.731, 'Information Technology - Open Systems Interconnection - System Management: State Management Function', 1992" SYNTAX BITS { notSupported(0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning(6), indeterminate(7) } -- -- Node definitions -- hwEntityExtObjects OBJECT IDENTIFIER ::= { hwEntityExtentMIB 1 } -- MIB contains four groups -- hwEntityState OBJECT IDENTIFIER ::= { hwEntityExtObjects 1 } hwEntityStateTable OBJECT-TYPE SYNTAX SEQUENCE OF HwEntityStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per physical entity, There is always at least one row for an 'overall' physical entity. The information in each row may be not include all the object in this table, because of the entity need not some of the information here. " ::= { hwEntityState 1 } hwEntityStateEntry OBJECT-TYPE SYNTAX HwEntityStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular physical entity. Each entry provides objects (entPhysicalDescr, entPhysicalVendorType, and entPhysicalClass) to help an NMS identify and characterize the entry, and objects (entPhysicalContainedIn and entPhysicalParentRelPos) to help an NMS relate the particular entry to other entries in this table." INDEX { entPhysicalIndex } ::= { hwEntityStateTable 1 } HwEntityStateEntry ::= SEQUENCE { hwEntityAdminStatus HwAdminState, hwEntityOperStatus HwOperState, hwEntityStandbyStatus HwStandbyStatus, hwEntityAlarmLight HwAlarmStatus, hwEntityCpuUsage INTEGER, hwEntityCpuUsageThreshold INTEGER, hwEntityMemUsage INTEGER, hwEntityMemUsageThreshold INTEGER, hwEntityMemSize Integer32, hwEntityUpTime Integer32, hwEntityTemperature Integer32, hwEntityTemperatureThreshold Integer32, hwEntityVoltage Integer32, hwEntityVoltageLowThreshold Integer32, hwEntityVoltageHighThreshold Integer32, hwEntityTemperatureLowThreshold Integer32, hwEntityOpticalPower Integer32, hwEntityCurrent Integer32, hwEntityMemSizeMega Integer32, hwEntityPortType INTEGER, hwEntityDuplex INTEGER, hwEntityOpticalPowerRx Integer32, hwEntityCpuUsageLowThreshold Integer32 } hwEntityAdminStatus OBJECT-TYPE SYNTAX HwAdminState MAX-ACCESS read-write STATUS current DESCRIPTION " The administrative state for this object, and it is possible to set the state when needed. " ::= { hwEntityStateEntry 1 } hwEntityOperStatus OBJECT-TYPE SYNTAX HwOperState MAX-ACCESS read-only STATUS current DESCRIPTION " The operational state for this object. " ::= { hwEntityStateEntry 2 } hwEntityStandbyStatus OBJECT-TYPE SYNTAX HwStandbyStatus MAX-ACCESS read-only STATUS current DESCRIPTION " Some entity in a device can support standby mode, This object is used for monitoring standby status. " ::= { hwEntityStateEntry 3 } hwEntityAlarmLight OBJECT-TYPE SYNTAX HwAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION " The alarm status for this entity. It does not include the severity of alarms raised on child components. On the condition, there are a alarm light on the entity, the object should have the same status with it." ::= { hwEntityStateEntry 4 } hwEntityCpuUsage OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION " The CPU usage for this entity. Generally, the CPU usage will calculate the overall CPU usage on the entity, and it is not sensible with the number of CPU on the entity. " ::= { hwEntityStateEntry 5 } hwEntityCpuUsageThreshold OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-write STATUS current DESCRIPTION " The threshold for the CPU usage. When the CPU usage exceed the threshold, a notification will be sent. " ::= { hwEntityStateEntry 6 } hwEntityMemUsage OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION " The memory usage for the entity. This object point out how many percent of memory has been used. " ::= { hwEntityStateEntry 7 } hwEntityMemUsageThreshold OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-write STATUS current DESCRIPTION " The threshold for the Memory usage, When the memory usage exceed the threshold, a notification will be sent. " ::= { hwEntityStateEntry 8 } hwEntityMemSize OBJECT-TYPE SYNTAX Integer32 UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION " The size of memory for the entity. " ::= { hwEntityStateEntry 9 } hwEntityUpTime OBJECT-TYPE SYNTAX Integer32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION " The up time for the entity. The mean of up time is when the entity is up, and the value of the object will add one per seconds while the entity running. " ::= { hwEntityStateEntry 10 } hwEntityTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The temperature for the entity. " ::= { hwEntityStateEntry 11 } hwEntityTemperatureThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The threshold for the temperature. When the temperature exceed the threshold, a notification will be sent. " ::= { hwEntityStateEntry 12 } hwEntityVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The voltage for the entity. " ::= { hwEntityStateEntry 13 } hwEntityVoltageLowThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The low-threshold for the voltage. Generally, we have two threshold for the voltage, one is low-threshold, and the other is high-threshold. the normal status of voltage should be greater than the low-threshold, and lower than the high-threshold. When the voltage low than the low-threshold, a notification will be sent. " ::= { hwEntityStateEntry 14 } hwEntityVoltageHighThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The low-threshold for the voltage. Generally, we have two threshold for the voltage, one is low-threshold, and the other is high-threshold. the normal status of voltage should be greater than the low-threshold, and lower than the high-threshold. When the voltage greater than the high-threshold, a notification will be sent. " ::= { hwEntityStateEntry 15 } hwEntityTemperatureLowThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The low-threshold of temperature. If the device temperature is lower than the threshold, an alarm is raised. " ::= { hwEntityStateEntry 16 } hwEntityOpticalPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The optical power of the optical module. Unit: uW" ::= { hwEntityStateEntry 17 } hwEntityCurrent OBJECT-TYPE SYNTAX Integer32 UNITS "A" MAX-ACCESS read-only STATUS current DESCRIPTION " The current for the entity. " ::= { hwEntityStateEntry 18 } hwEntityMemSizeMega OBJECT-TYPE SYNTAX Integer32 UNITS "M bytes" MAX-ACCESS read-only STATUS current DESCRIPTION " The size of SDRAM(Synchronous Dynamic Random Access Memory) memory for the entity. Unit: M bytes" ::= { hwEntityStateEntry 19 } hwEntityPortType OBJECT-TYPE SYNTAX INTEGER { notSupported(1), copper(2), fiber100(3), fiber1000(4) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the type of the Ethernet interface: an optical interface or an electrical interface. " ::= { hwEntityStateEntry 20 } hwEntityDuplex OBJECT-TYPE SYNTAX INTEGER { notSupported(1), full(2), half(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the duplex mode of the Ethernet interface. An electrical Ethernet interface can work in half-duplex mode or full-duplex mode. An optical Ethernet can work only in full-duplex mode. " ::= { hwEntityStateEntry 21 } hwEntityOpticalPowerRx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The optical power(Rx) of the optical module. Unit: uW" ::= { hwEntityStateEntry 22 } hwEntityCpuUsageLowThreshold OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-write STATUS current DESCRIPTION " The threshold for the CPU usage. When the CPU usage exceed the threshold, a notification will be sent. " ::= { hwEntityStateEntry 23 } hwRUModuleInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF HwRUModuleInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per replaceable unit physical entity. The row with the field 'entPhysicalIsFRU' sets to 'true' in table 'entPhysicalTable' will be mapped to one row in this table." ::= { hwEntityState 2 } hwRUModuleInfoEntry OBJECT-TYPE SYNTAX HwRUModuleInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a replaceable unit physical entity. Each entry provides objects of a replaceable unit to help an NMS identify and characterize the entry in this table. " INDEX { entPhysicalIndex } ::= { hwRUModuleInfoTable 1 } HwRUModuleInfoEntry ::= SEQUENCE { hwEntityBomId SnmpAdminString, hwEntityBomEnDesc SnmpAdminString, hwEntityBomLocalDesc SnmpAdminString, hwEntityManufacturedDate DateAndTime, hwEntityManufactureCode Integer32, hwEntityCLEICode SnmpAdminString, hwEntityUpdateLog SnmpAdminString, hwEntityArchivesInfoVersion SnmpAdminString, hwEntityOpenBomId SnmpAdminString, hwEntityIssueNum SnmpAdminString, hwEntityBoardType SnmpAdminString } hwEntityBomId OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The identity of the Bill of Material about this replaceable unit which coded by vendor. This node is mapping to 'ITEM' in the information file. " ::= { hwRUModuleInfoEntry 1 } hwEntityBomEnDesc OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The English description of the Bill of Material about this replaceable unit. " ::= { hwRUModuleInfoEntry 2 } hwEntityBomLocalDesc OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The local description of the Bill of Material about this replaceable unit. " ::= { hwRUModuleInfoEntry 3 } hwEntityManufacturedDate OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The date when this physical entity is Manufactured. " ::= { hwRUModuleInfoEntry 4 } hwEntityManufactureCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The code of the place where this physical entity is Manufactured. " ::= { hwRUModuleInfoEntry 5 } hwEntityCLEICode OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The string code of CLEI which was granted by America. " ::= { hwRUModuleInfoEntry 6 } hwEntityUpdateLog OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The maintenance log of this replaceable unit. " ::= { hwRUModuleInfoEntry 7 } hwEntityArchivesInfoVersion OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The Version of Archives Information. " ::= { hwRUModuleInfoEntry 8 } hwEntityOpenBomId OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The BomId for distribution. It is different from hwEntityBomId." ::= { hwRUModuleInfoEntry 9 } hwEntityIssueNum OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The issue number for hardware change." ::= { hwRUModuleInfoEntry 10 } hwEntityBoardType OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The type code for entity." ::= { hwRUModuleInfoEntry 11 } hwOpticalModuleInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF HwOpticalModuleInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of optical module properties." ::= { hwEntityState 3 } hwOpticalModuleInfoEntry OBJECT-TYPE SYNTAX HwOpticalModuleInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table of optical module properties for each optical module." INDEX { entPhysicalIndex } ::= { hwOpticalModuleInfoTable 1 } HwOpticalModuleInfoEntry ::= SEQUENCE { hwEntityOpticalMode INTEGER, hwEntityOpticalWaveLength Integer32, hwEntityOpticalTransDistance Integer32, hwEntityOpticalVendorSn SnmpAdminString, hwEntityOpticalTemperature Integer32, hwEntityOpticalVoltage Integer32, hwEntityOpticalBiasCurrent Integer32, hwEntityOpticalRxPower Integer32, hwEntityOpticalTxPower Integer32 } hwEntityOpticalMode OBJECT-TYPE SYNTAX INTEGER { notSupported(1), singleMode(2), multiMode5(3), multiMode6(4), noValue(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The mode of the optical module." DEFVAL { notSupported } ::= { hwOpticalModuleInfoEntry 1 } hwEntityOpticalWaveLength OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The wave length of the optical module. Unit: nm." ::= { hwOpticalModuleInfoEntry 2 } hwEntityOpticalTransDistance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The max transmission distance of the optical module. Unit: m." ::= { hwOpticalModuleInfoEntry 3 } hwEntityOpticalVendorSn OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "The vendor serial number (vendor SN) of the optical module. Length: 16 bytes." ::= { hwOpticalModuleInfoEntry 4 } hwEntityOpticalTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current temperature of the optical module. Unit: ¡æ." ::= { hwOpticalModuleInfoEntry 5 } hwEntityOpticalVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current voltage of the optical module. Unit: mV." ::= { hwOpticalModuleInfoEntry 6 } hwEntityOpticalBiasCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The bias current of the optical module. Unit: mA." ::= { hwOpticalModuleInfoEntry 7 } hwEntityOpticalRxPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The receive power of the optical module. Unit: uW." ::= { hwOpticalModuleInfoEntry 8 } hwEntityOpticalTxPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmit power of the optical module. Unit: uW." ::= { hwOpticalModuleInfoEntry 9 } hwMonitorInputTable OBJECT-TYPE SYNTAX SEQUENCE OF HwMonitorInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per replaceable unit physical entity. This table is used to set the status of monitor port." ::= { hwEntityState 4 } hwMonitorInputEntry OBJECT-TYPE SYNTAX HwMonitorInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a replaceable unit physical entity." INDEX { hwMonitorInputIndex } ::= { hwMonitorInputTable 1 } HwMonitorInputEntry ::= SEQUENCE { hwMonitorInputIndex Integer32, hwMonitorInputName DisplayString, hwMonitorInputState HWLevelState, hwMonitorInputStateEnable EnabledStatus, hwMonitorInputRowStatus RowStatus } hwMonitorInputIndex OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Monitor port index. This is a number of input line,ranging from 1 to 4. " ::= { hwMonitorInputEntry 1 } hwMonitorInputName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Monitor line name. " ::= { hwMonitorInputEntry 2 } hwMonitorInputState OBJECT-TYPE SYNTAX HWLevelState MAX-ACCESS read-create STATUS current DESCRIPTION "Monitor line status. The value is high or low. " ::= { hwMonitorInputEntry 3 } hwMonitorInputStateEnable OBJECT-TYPE SYNTAX EnabledStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Enable monitor line. " ::= { hwMonitorInputEntry 4 } hwMonitorInputRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Status of monitor input row. " ::= { hwMonitorInputEntry 5 } hwMonitorOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF HwMonitorOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per replaceable unit physical entity. This table is used to create a output view." ::= { hwEntityState 5} hwMonitorOutputEntry OBJECT-TYPE SYNTAX HwMonitorOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a replaceable unit physical entity." INDEX { hwMonitorOutputIndex, hwMonitorOutputRuleIndex } ::= { hwMonitorOutputTable 1 } HwMonitorOutputEntry ::= SEQUENCE { hwMonitorOutputIndex Integer32, hwMonitorOutputRuleIndex Integer32, hwMonitorOutputMask DisplayString, hwMonitorOutputKey DisplayString, hwMonitorOutputRowStatus RowStatus } hwMonitorOutputIndex OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Monitor output view index. Through this index ,you can turn into the output view. " ::= { hwMonitorOutputEntry 1 } hwMonitorOutputRuleIndex OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Monitor output rule index. This is used to set the rules about all of the input line. " ::= { hwMonitorOutputEntry 2 } hwMonitorOutputMask OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Monitor output mask . This is used to matching the level of monitor input line. " ::= { hwMonitorOutputEntry 3 } hwMonitorOutputKey OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Normal level value of this output line. " ::= { hwMonitorOutputEntry 4 } hwMonitorOutputRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Status of monitor input row " ::= { hwMonitorOutputEntry 5 } hwEntPowerUsedInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF HwEntPowerUsedInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of information that displays the power use of entity ." ::= { hwEntityState 6 } hwEntPowerUsedInfoEntry OBJECT-TYPE SYNTAX HwEntPowerUsedInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of the table of information that displays the power use of entity." INDEX { entPhysicalIndex } ::= { hwEntPowerUsedInfoTable 1 } HwEntPowerUsedInfoEntry ::= SEQUENCE { hwEntPowerUsedInfoBoardName OCTET STRING, hwEntPowerUsedInfoBoardType OCTET STRING, hwEntPowerUsedInfoBoardSlot Integer32, hwEntPowerUsedInfoPower Integer32 } hwEntPowerUsedInfoBoardName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Board name." ::= { hwEntPowerUsedInfoEntry 1 } hwEntPowerUsedInfoBoardType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Board type." ::= { hwEntPowerUsedInfoEntry 2 } hwEntPowerUsedInfoBoardSlot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Board's slot number." ::= { hwEntPowerUsedInfoEntry 3 } hwEntPowerUsedInfoPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used power of board." ::= { hwEntPowerUsedInfoEntry 4 } -- ********************************************************** -- * Vitrual Cable Test ( Begin ) * -- ********************************************************** hwVirtualCableTestTable OBJECT-TYPE SYNTAX SEQUENCE OF HwVirtualCableTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per replaceable unit physical entity. This table is used to display VCT result." ::= { hwEntityState 7} hwVirtualCableTestEntry OBJECT-TYPE SYNTAX HwVirtualCableTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a replaceable unit physical entity." INDEX { hwVirtualCableTestIfIndex} ::= { hwVirtualCableTestTable 1 } HwVirtualCableTestEntry ::= SEQUENCE { hwVirtualCableTestIfIndex InterfaceIndex, hwVirtualCableTestPairStatus INTEGER, hwVirtualCableTestPairLength Integer32 } hwVirtualCableTestIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "IfIndex of port that you want to test cable." ::= { hwVirtualCableTestEntry 1 } hwVirtualCableTestPairStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), abnormalOpen(2), abnormalShort(3), abnormalOpenShort(4), abnormalCrossTalk(5), unknown(6), notSupport(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Pair status. This indicate the status of cable. " ::= { hwVirtualCableTestEntry 2 } hwVirtualCableTestPairLength OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Pair Length. This indicate the length of cable. " ::= { hwVirtualCableTestEntry 3 } -- ********************************************************** -- * Vitrual Cable Test ( End ) * -- ********************************************************** -- Notifications -- hwEntityExtTraps OBJECT IDENTIFIER ::= { hwEntityExtentMIB 2 } hwEntityExtTrapsPrefix OBJECT IDENTIFIER ::= { hwEntityExtTraps 0 } hwEntityExtTemperatureThresholdNotification NOTIFICATION-TYPE OBJECTS { hwEntityTemperature, hwEntityTemperatureThreshold, hwEntityAdminStatus, hwEntityAlarmLight } STATUS current DESCRIPTION " The hwEntityEnvTemperatureThresholdNotification indicates the temperature have been exceed the threshold. In the condition, user should check the hardware and the environment of the entity, sometimes it happened because of the failture of air-condition. Anyway, the threshold should lower than the value that most service work fine. " ::= { hwEntityExtTrapsPrefix 1 } hwEntityExtVoltageLowThresholdNotification NOTIFICATION-TYPE OBJECTS { hwEntityVoltage, hwEntityVoltageLowThreshold, hwEntityAdminStatus, hwEntityAlarmLight } STATUS current DESCRIPTION " The hwEntityExtVoltageLowThresholdNotification indicates the voltage is lower than the threshold. This may decrease the usability of the entity. If the voltage is lower too much than the hardware needed, the entity will stop working. Anyway, the threshold should higher than the value that most service work fine. " ::= { hwEntityExtTrapsPrefix 2 } hwEntityExtVoltageHighThresholdNotification NOTIFICATION-TYPE OBJECTS { hwEntityVoltage, hwEntityVoltageHighThreshold, hwEntityAdminStatus, hwEntityAlarmLight } STATUS current DESCRIPTION " The hwEntityExtVoltageHighThresholdNotification indicates the voltage is higher than the threshold. This may decrease the usability of the entity. If the voltage is higher too much than the hardware needed, the entity may be destroyed by the high voltage. Anyway, the threshold should lower than the value that most service work fine. " ::= { hwEntityExtTrapsPrefix 3 } hwEntityExtCpuUsageThresholdNotfication NOTIFICATION-TYPE OBJECTS { hwEntityCpuUsage, hwEntityCpuUsageThreshold, hwEntityTemperature, hwEntityTemperatureThreshold, hwEntityAdminStatus, hwEntityAlarmLight } STATUS current DESCRIPTION " The hwEntityExtCpuUsageThresholdNotfication indicates the entity is overload, and the service running in the entity will not get the performance it should because of CPU's performance. Anyway, the threshold should lower than the value that most service work fine. " ::= { hwEntityExtTrapsPrefix 4 } hwEntityExtMemUsageThresholdNotification NOTIFICATION-TYPE OBJECTS { hwEntityMemUsage, hwEntityMemUsageThreshold, hwEntityMemSize, hwEntityAdminStatus, hwEntityAlarmLight } STATUS current DESCRIPTION " The hwEntityExtMemUsageThresholdNotification indicates the entity is overload, and the service running in the entity will not get the performance it should because of lower memory. Anyway, the threshold should lower than the value that most service work fine. " ::= { hwEntityExtTrapsPrefix 5 } hwEntityExtOperEnabled NOTIFICATION-TYPE OBJECTS { hwEntityAdminStatus, hwEntityAlarmLight } STATUS current DESCRIPTION "The entity is operational. The entity this notification refers can be identified by extracting the entPhysicalIndex from one of the variable bindings." ::= { hwEntityExtTrapsPrefix 6 } hwEntityExtOperDisabled NOTIFICATION-TYPE OBJECTS { hwEntityAdminStatus, hwEntityAlarmLight } STATUS current DESCRIPTION "The entity is operational. The entity this notification refers can be identified by extracting the entPhysicalIndex from one of the variable bindings." ::= { hwEntityExtTrapsPrefix 7 } hwEntityExtMonitorBoardAbnormalNotification NOTIFICATION-TYPE STATUS current DESCRIPTION "The monitor board turns normal to abnormal." ::= { hwEntityExtTrapsPrefix 8 } hwEntityExtMonitorBoardNormalNotification NOTIFICATION-TYPE STATUS current DESCRIPTION "The monitor board turns abnormal to normal." ::= { hwEntityExtTrapsPrefix 9 } hwEntityExtMonitorPortAbnormalNotification NOTIFICATION-TYPE OBJECTS { hwMonitorInputState, hwMonitorInputName } STATUS current DESCRIPTION "The monitor port turns normal to abnormal." ::= { hwEntityExtTrapsPrefix 10 } hwEntityExtMonitorPortNormalNotification NOTIFICATION-TYPE OBJECTS { hwMonitorInputState, hwMonitorInputName } STATUS current DESCRIPTION "The monitor port turns abnormal to normal." ::= { hwEntityExtTrapsPrefix 11 } hwEntityExtCpuUsageLowThresholdNotfication NOTIFICATION-TYPE OBJECTS { hwEntityCpuUsage, hwEntityCpuUsageThreshold, hwEntityTemperature, hwEntityTemperatureThreshold, hwEntityAdminStatus, hwEntityAlarmLight } STATUS current DESCRIPTION " The hwEntityExtCpuUsageThresholdNotfication indicates the entity is overload, and the service running in the entity will not get the performance it should because of CPU's performance. Anyway, the threshold should lower than the value that most service work fine. " ::= { hwEntityExtTrapsPrefix 12 } hwDevicePowerInfoObjects OBJECT IDENTIFIER ::= { hwEntityExtentMIB 3 } hwDevicePowerInfoTotalPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Device total power." ::= { hwDevicePowerInfoObjects 1 } hwDevicePowerInfoUsedPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Device used power." ::= { hwDevicePowerInfoObjects 2 } -- Conformance and Compliance -- hwEntityExtConformance OBJECT IDENTIFIER ::= { hwEntityExtentMIB 4 } hwEntityExtCompliances OBJECT IDENTIFIER ::= { hwEntityExtConformance 1 } -- this module hwEntityExtCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for systems supporting the HUAWEI Entity extent MIB." MODULE -- this module MANDATORY-GROUPS { hwEntityExtGroup } OBJECT hwEntityAdminStatus MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT hwEntityCpuUsageThreshold MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT hwEntityMemUsageThreshold MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT hwEntityTemperatureThreshold MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT hwEntityVoltageLowThreshold MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT hwEntityVoltageHighThreshold MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { hwEntityExtCompliances 1 } hwEntityExtGroups OBJECT IDENTIFIER ::= { hwEntityExtConformance 2 } hwEntityExtGroup OBJECT-GROUP OBJECTS { hwEntityAdminStatus, hwEntityOperStatus, hwEntityStandbyStatus, hwEntityAlarmLight, hwEntityCpuUsage, hwEntityCpuUsageThreshold, hwEntityMemUsage, hwEntityMemUsageThreshold, hwEntityMemSize, hwEntityUpTime, hwEntityTemperature, hwEntityTemperatureThreshold, hwEntityVoltage, hwEntityVoltageLowThreshold, hwEntityVoltageHighThreshold, hwEntityTemperatureLowThreshold, hwEntityOpticalPower, hwEntityCurrent, hwEntityMemSizeMega,hwEntityPortType,hwEntityDuplex,hwEntityOpticalPowerRx, hwEntityCpuUsageLowThreshold } STATUS current DESCRIPTION "Standard HUAWEI Entity Extent group." ::= { hwEntityExtGroups 1 } hwEntityExtNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { hwEntityExtTemperatureThresholdNotification, hwEntityExtVoltageLowThresholdNotification, hwEntityExtVoltageHighThresholdNotification, hwEntityExtCpuUsageThresholdNotfication, hwEntityExtMemUsageThresholdNotification, hwEntityExtOperEnabled, hwEntityExtOperDisabled, hwEntityExtMonitorBoardAbnormalNotification,hwEntityExtMonitorBoardNormalNotification,hwEntityExtMonitorPortAbnormalNotification, hwEntityExtMonitorPortNormalNotification , hwEntityExtCpuUsageLowThresholdNotfication} STATUS current DESCRIPTION "Standard HUAWEI Entity Extent Notification group." ::= { hwEntityExtGroups 2 } hwRUModuleInfoGroup OBJECT-GROUP OBJECTS { hwEntityBomId, hwEntityBomEnDesc, hwEntityManufacturedDate, hwEntityCLEICode, hwEntityArchivesInfoVersion, hwEntityOpenBomId, hwEntityIssueNum, hwEntityBoardType } STATUS current DESCRIPTION "Standard HUAWEI Entity Extent group." ::= { hwEntityExtGroups 3 } hwEntityExtOldObjectsGroup OBJECT-GROUP OBJECTS { hwEntityBomLocalDesc, hwEntityManufactureCode, hwEntityUpdateLog } STATUS obsolete DESCRIPTION "Group for old objects that may be obsoleted." ::= { hwEntityExtGroups 4 } hwOpticalModuleInfoGroup OBJECT-GROUP OBJECTS { hwEntityOpticalMode, hwEntityOpticalWaveLength, hwEntityOpticalTransDistance, hwEntityOpticalVendorSn,hwEntityOpticalTemperature, hwEntityOpticalVoltage, hwEntityOpticalBiasCurrent, hwEntityOpticalRxPower, hwEntityOpticalTxPower } STATUS current DESCRIPTION "Collection of objects that display the fiber module working information." ::= { hwEntityExtGroups 5 } hwMonitorInputGroup OBJECT-GROUP OBJECTS { hwMonitorInputName, hwMonitorInputState, hwMonitorInputStateEnable, hwMonitorInputRowStatus } STATUS current DESCRIPTION "Standard HUAWEI Entity Extent group." ::= { hwEntityExtGroups 6 } hwMonitorOutputGroup OBJECT-GROUP OBJECTS { hwMonitorOutputMask, hwMonitorOutputKey, hwMonitorOutputRowStatus } STATUS current DESCRIPTION "Standard HUAWEI Entity Extent group." ::= { hwEntityExtGroups 7 } hwEntPowerUsedInfoGroup OBJECT-GROUP OBJECTS { hwEntPowerUsedInfoBoardName, hwEntPowerUsedInfoBoardType, hwEntPowerUsedInfoBoardSlot, hwEntPowerUsedInfoPower } STATUS current DESCRIPTION "Collection of objects that display the power informations of entity." ::= { hwEntityExtGroups 8 } hwDevicePowerInfoGroup OBJECT-GROUP OBJECTS { hwDevicePowerInfoTotalPower, hwDevicePowerInfoUsedPower } STATUS current DESCRIPTION "Collection of objects that display the power informations of device." ::= { hwEntityExtGroups 9 } hwVirtualCableTestGroup OBJECT-GROUP OBJECTS { hwVirtualCableTestPairStatus, hwVirtualCableTestPairLength } STATUS current DESCRIPTION "Collection of objects that display the status of cable." ::= { hwEntityExtGroups 10 } END -- -- HUAWEI-ENTITY-EXTENT-MIB.mib --