source: Alerting/Macros.md # Macros Macros are shorthands to either portion of rules or pure SQL enhanced with placeholders. You can define your own macros in your `config.php`. Example macro-implementation of Debian-Devices ```php $config['alert']['macros']['rule']['is_debian'] = '%devices.features ~ "@debian@"'; ``` And in the Rule: ``` ... && %macros.is_debian = "1" && ... ``` This Example-macro is a Boolean-macro, it applies a form of filter to the set of results defined by the rule. All macros that are not unary should return Boolean. You can only apply _Equal_ or _Not-Equal_ Operations on Boolean-macros where `True` is represented by `"1"` and `False` by `"0"`. Example ```php ((%ports.ifInOctets_rate*8) / %ports.ifSpeed)*100 ``` ## Device (Boolean) Entity: `%macros.device` Description: Only select devices that aren't deleted, ignored or disabled. Source: `(%devices.disabled = "0" && %devices.ignore = "0")` ### Device is up (Boolean) Entity: `%macros.device_up` Description: Only select devices that are up. Implies: %macros.device Source: `(%devices.status = "1" && %macros.device)` ### Device is down (Boolean) Entity: `%macros.device_down` Description: Only select devices that are down. Implies: %macros.device Source: `(%devices.status = "0" && %macros.device)` ## Port (Boolean) Entity: `%macros.port` Description: Only select ports that aren't deleted, ignored or disabled. Source: `(%ports.deleted = "0" && %ports.ignore = "0" && %ports.disabled = "0")` ### Port is up (Boolean) Entity: `%macros.port_up` Description: Only select ports that are up and also should be up. Implies: %macros.port Source: `(%ports.ifOperStatus = "up" && %ports.ifAdminStatus = "up" && %macros.port)` ### Port is down (Boolean) Entity: `%macros.port_down` Description: Only select ports that are down. Implies: %macros.port Source: `(%ports.ifOperStatus = "down" && %ports.ifAdminStatus != "down" && %macros.port)` ### Port-Usage in Percent (Decimal) Entity: `%macros.port_usage_perc` Description: Return port-usage in percent. Source: `((%ports.ifInOctets_rate*8) / %ports.ifSpeed)*100` ## Time ### Now (Datetime) Entity: `%macros.now` Description: Alias of MySQL's NOW() Source: `NOW()` ### Past N Minutes (Datetime) Entity: `%macros.past_$m` Description: Returns a MySQL Timestamp dated `$` Minutes in the past. `$` can only be a supported Resolution. Example: `%macros.past_5m` is Last 5 Minutes. Resolution: 5,10,15,30,60 Source: `DATE_SUB(NOW(),INTERVAL $ MINUTE)` ## Sensors (Boolean) Entity: `%macros.sensor` Description: Only select sensors that aren't ignored. Source: `(%sensors.sensor_alert = 1)` Entity: `%macros.sensor_port_link` Description: Only selects sensors that have a port linked to them, the port is up and the device is up. Source: `(%sensors.entity_link_type = 'port' && %sensors.entity_link_index = %ports.ifIndex && %macros.port_up && %macros.device_up))` ## Misc (Boolean) ### Packet Loss Entity: `(%macros.packet_loss_5m)` Description: Packet loss % value for the device within the last 5 minutes. Example: `%macros.packet_loss_5m` > 50 Entity: `(%macros.packet_loss_15m)` Description: Packet loss % value for the device within the last 15 minutes. Example: `%macros.packet_loss_15m` > 50 ### Ports in usage perc (Int) Entity: `((%ports.ifInOctets_rate*8)/%ports.ifSpeed)*100` Description: Port in used more than 50% Example: `%macros.port_in_usage_perc > 50 ### Ports out usage perc (Int) Entity: `((%ports.ifOutOctets_rate*8)/%ports.ifSpeed)*100` Description: Port out used more than 50% Example: `%macros.port_out_usage_perc > 50 ### Ports now down (Boolean) Entity: `%ports.ifOperStatus != %ports.ifOperStatus_prev && %ports.ifOperStatus_prev = "up" && %ports.ifAdminStatus = "up"` Description: Ports that were previously up and have now gone down. Example: `%macros.port_now_down = "1"` ### Device component down [JunOS] Entity: `%sensors.sensor_class = "state" && %sensors.sensor_current != "6" && %sensors.sensor_type = "jnxFruState" && %sensors.sensor_current != "2"` Description: Device component is down such as Fan, PSU, etc for JunOS devices. Example: `%macros.device_component_down_junos = "1"` ### Device component down [Cisco] Entity: `%sensors.sensor_current != "1" && %sensors.sensor_current != "5" && %sensors.sensor_type ~ "^cisco.*State$"` Description: Device component is down such as Fan, PSU, etc for Cisco devices. Example: `%macros.device_component_down_cisco = "1"` ### PDU over amperage [APC] Entity: `%sensors.sensor_class = "current" && %sensors.sensor_descr = "Bank Total" && %sensors.sensor_current > %sensors.sensor_limit && %devices.os = "apc"` Description: APC PDU over amperage Example: `%macros.pdu_over_amperage_apc = "1"`