SWITCH-CHASSIS-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, IpAddress, Counter32, Unsigned32 FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString, MacAddress, RowStatus, TimeStamp FROM SNMPv2-TC switchChassis FROM TELESYN-ATI-TC; switchChassisMib MODULE-IDENTITY LAST-UPDATED "9704292000Z" ORGANIZATION "" CONTACT-INFO "" DESCRIPTION "The MIB module for SWITCH chassis entity." REVISION "9704292000Z" DESCRIPTION "Changed the status of the objects in ipParams group to obsolete. The objects in this group are defined elsewhere or not applicable." REVISION "9701142000Z" DESCRIPTION "Redefined the TFTP objects in TftpGroup for executing a file transfer between the chassis and the TFTP server. Deprecated the Console objects." REVISION "9612192200Z" DESCRIPTION "Initial Release." ::= { switchChassis 1 } HostNameOrIpAddr ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The DNS, NIS (or equivalent name), or the ip address (in dotted quad notation) of the host." SYNTAX DisplayString HwIdentifier ::= TEXTUAL-CONVENTION DISPLAY-HINT "2d.2d" STATUS current DESCRIPTION "The hardware identifier consists of 2 16 bit values, called major and minor. The first 2 octets contain the major number; the second 2 octets contain the minor number." SYNTAX OCTET STRING (SIZE(4)) SwVersionId ::= TEXTUAL-CONVENTION DISPLAY-HINT "2d.2d.2d" STATUS current DESCRIPTION "The software version id consists of 3 16 bit values. The first 2 octets contain the major number; the octets 3, 4 contain the minor number, octets 5,6 contain a release number." SYNTAX OCTET STRING (SIZE(6)) chassisParams OBJECT IDENTIFIER ::= { switchChassisMib 1 } ipParams OBJECT IDENTIFIER ::= { switchChassisMib 3 } sysConfigParams OBJECT IDENTIFIER ::= { switchChassisMib 4 } snmpParams OBJECT IDENTIFIER ::= { switchChassisMib 6 } consoleParams OBJECT IDENTIFIER ::= { switchChassisMib 7 } logParams OBJECT IDENTIFIER ::= { switchChassisMib 8 } bootParams OBJECT IDENTIFIER ::= { switchChassisMib 9 } chassisSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number of the chassis." ::= { chassisParams 1 } chassisHwId OBJECT-TYPE SYNTAX HwIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "A version number for the motherboard - first 16 bits is the major number, second 16 bits is the minor number." ::= { chassisParams 2 } chassisOSVersion OBJECT-TYPE SYNTAX DisplayString(SIZE(0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION " Software version of the operating system kernel." ::= { chassisParams 3 } chassisFwVersion OBJECT-TYPE SYNTAX DisplayString(SIZE(0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The chassis firmware version. " ::= { chassisParams 4 } chassisLastChanges OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Counts the number of times the system config file has been written to flash since last reboot." ::= { chassisParams 5 } chassisBaseMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This object is the 6-byte 'base' MAC address for this chassis." ::= { chassisParams 6 } chassisFanStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), slowOrStopped(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational status of fan. 'slowOrStopped' indicates the fan rpm is lower than a minimum required value." ::= { chassisParams 7 } chassisBoardSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number of the mother board." ::= { chassisParams 8 } ipAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS obsolete DESCRIPTION "The IP address that the device will use after a restart. The device's active IP address can be determined by examining the appropriate instance of the ipAdEntAddr attribute of the MIB-II IP address table." ::= { ipParams 1 } ipNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS obsolete DESCRIPTION "The subnet mask that the device will use after a restart. The device's active subnet mask can be determined by examining the appropriate instance of the ipAdEntNetMask attribute of the MIB-II IP address table." ::= { ipParams 2 } ipBcastForm OBJECT-TYPE SYNTAX INTEGER { allOnes(1), allZeros(2) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "The type of IP broadcast address that the device will use after a restart: the Internet standard all-ones broadcast address or the non- standard all zeros broadcast address. The device's active broadcast address type can be determined by examining the appropriate instance of the ipAdEntBcastAddr attribute of the MIB-II IP address table." ::= { ipParams 3 } ipEncap OBJECT-TYPE SYNTAX INTEGER { ethernet(1), ieee8022(2) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "The type of IP datagram encapsulation that the device will use after a restart: Ethernet or IEEE802.2. The active type of IP datagram encapsulation can be determined by examining the appropriate instance of the ifType attribute of the MIB-II interfaces table entry for the device's Ethernet interface. If the value of that instance of ifType is ethernet-csmacd(6), then the active type of IP datagram encapsulation is Ethernet; if the value of that instance of ifType is iso88023-csmacd(7), then the active type of IP datagram encapsulation is IEEE802.2." ::= { ipParams 4 } ipDefaultGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS obsolete DESCRIPTION "The default gateway IP address that the device will use after a restart. The device's operational default gateway IP address can be determined by examining the value of the ipRouteNextHop.0.0.0.0 attribute of the MIB-II IP routing table." ::= { ipParams 5 } ipDomainName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..63)) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "The device's domain name." ::= { ipParams 6 } bootFlag OBJECT-TYPE SYNTAX INTEGER { bootSystem(0), skipPost(1), runMonitor(2), useBackupBoot(4), loopPost(8), bootLoader(16), bootNetwork(32), bootDiag(48), networkEth0(64), networkEth1(128), networkCom0(192) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION " Boot flags to define the startup parameters" ::= { sysConfigParams 1 } dramSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "DRAM size in bytes" ::= { sysConfigParams 2 } cpuVer OBJECT-TYPE SYNTAX HwIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION " Hardware identifier of the processor." ::= { sysConfigParams 3 } iscVer OBJECT-TYPE SYNTAX HwIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION " Hardware identifier of the Galileo chip." ::= { sysConfigParams 4 } pigVer OBJECT-TYPE SYNTAX HwIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware identifier of the PIG chip." ::= { sysConfigParams 5 } postVer OBJECT-TYPE SYNTAX SwVersionId MAX-ACCESS read-only STATUS current DESCRIPTION "Software version of the POST diagnostic." ::= { sysConfigParams 6 } isdVer OBJECT-TYPE SYNTAX SwVersionId MAX-ACCESS read-only STATUS current DESCRIPTION " Software version of the ISD diagnostic." ::= { sysConfigParams 7 } bootVer OBJECT-TYPE SYNTAX SwVersionId MAX-ACCESS read-only STATUS current DESCRIPTION "Software version of the boot prom." ::= { sysConfigParams 8 } qmuMemSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "QME memory size" ::= { sysConfigParams 9 } segBusTable OBJECT-TYPE SYNTAX SEQUENCE OF SegBusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of attributes associated with segBus." ::= { sysConfigParams 10 } segBusEntry OBJECT-TYPE SYNTAX SegBusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of attributes associated with a segBus." INDEX { segBusIndex } ::= { segBusTable 1 } SegBusEntry ::= SEQUENCE { segBusIndex INTEGER, segBusPmiuId HwIdentifier, segBusQmuId HwIdentifier } segBusIndex OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS not-accessible STATUS current DESCRIPTION "SegBus number" ::= { segBusEntry 1 } segBusPmiuId OBJECT-TYPE SYNTAX HwIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware identifier of the Port Manager Interface Unit (PMIU) chip " ::= { segBusEntry 2 } segBusQmuId OBJECT-TYPE SYNTAX HwIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware identifier of the Queue Management Unit (QMU) chip " ::= { segBusEntry 3 } snmpIpTrapRcvrTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpIpTrapRcvrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of entries containing information about network management stations with Ip addresses that are to receive traps generated by this device over UDP." ::= { snmpParams 1 } snmpIpTrapRcvrEntry OBJECT-TYPE SYNTAX SnmpIpTrapRcvrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing information about a single network management station with an Ip address that is to receive traps generated by this device over UDP." INDEX { snmpIpTrapRcvrIpAddress } ::= { snmpIpTrapRcvrTable 1 } SnmpIpTrapRcvrEntry ::= SEQUENCE { snmpIpTrapRcvrIpAddress IpAddress, snmpIpTrapRcvrPort INTEGER, snmpIpTrapRcvrCommunity DisplayString, snmpIpTrapRcvrStatus RowStatus } snmpIpTrapRcvrIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Ip address of this trap receiver." ::= { snmpIpTrapRcvrEntry 1 } snmpIpTrapRcvrPort OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "The UDP port number for the Trap receiver." ::= { snmpIpTrapRcvrEntry 2 } snmpIpTrapRcvrCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE(1..64)) MAX-ACCESS read-create STATUS current DESCRIPTION "The community string to be specified in traps sent to this ip trap receiver." DEFVAL { "public" } ::= { snmpIpTrapRcvrEntry 3 } snmpIpTrapRcvrStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to create or delete entries in the snmpIpTrapRcvrTable." ::= { snmpIpTrapRcvrEntry 4 } snmpUnAuthIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the last management station that attempted to access this agent with an invalid community string. This object is used as a variable binding in an Authentication Failure Trap-PDU." ::= { snmpParams 2 } snmpUnAuthCommunity OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The community string specified by the most recent unauthenticated attempt to access this agent. This object is used as a variable binding in an Authentication Failure Trap-PDU." ::= { snmpParams 3 } consolePortSpeed OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS deprecated DESCRIPTION "The speed of the console port in bits per second." ::= { consoleParams 1 } consolePortDataBits OBJECT-TYPE SYNTAX INTEGER (7..8) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "The console port's number of data bits." ::= { consoleParams 2 } consolePortStopBits OBJECT-TYPE SYNTAX INTEGER { one(1), two(2), onePointFive(3) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "The console port's number of stop bits." ::= { consoleParams 3 } consolePortParity OBJECT-TYPE SYNTAX INTEGER { none(1), odd(2), even(3), mark(4), space(5) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "The console port's parity setting." ::= { consoleParams 4 } eventLogEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this object indicates whether or not system event logging is currently enabled. Changes to this object take effect immediately." ::= { logParams 1 } eventLogSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of entries retrievable from the system event log. If the value of this object is greater than the value of the eventLogCount object, then only eventLogCount entries have been logged and can be retrieved." ::= { logParams 2 } eventLogCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of events logged to the system event log. If the value of this object exceeds the value of the eventLogSize object, only the most recent eventLogSize entries can be retrieved. Setting the value of this object to zero clears the device's system event log." ::= { logParams 3 } eventLogTable OBJECT-TYPE SYNTAX SEQUENCE OF EventLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of system event log entries." ::= { logParams 4 } eventLogEntry OBJECT-TYPE SYNTAX EventLogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A single system event log entry." INDEX { eventLogIndex } ::= { eventLogTable 1 } EventLogEntry ::= SEQUENCE { eventLogIndex INTEGER, eventLogTime DisplayString, eventLogDescr DisplayString, eventLogDetail DisplayString, eventLogRawEntry OCTET STRING } eventLogIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value for each entry in the event log. Its value is between 1 and the minimum of the value of the eventLogSize and eventLogCount objects. The oldest event in the log corresponds to index 1." ::= { eventLogEntry 1 } eventLogTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The time (according to the system clock) in human-readable form at which this system event log entry was logged." ::= { eventLogEntry 2 } eventLogDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A human-readable string describing the event represented by this system event log entry." ::= { eventLogEntry 3 } eventLogDetail OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A human-readable string providing more detailed information about the event respresented by this system event log entry." ::= { eventLogEntry 4 } eventLogRawEntry OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The first 255 octets of raw, unformatted system event log entry as it appears internally." ::= { eventLogEntry 5 } deviceReset OBJECT-TYPE SYNTAX INTEGER { noOp(1), reset(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this object returned in response to an SNMP Get or Get-Next request is always noOp(1). Changing the value of this object to reset(2) will cause the device to be reset." ::= { bootParams 1 } tftpGroup OBJECT IDENTIFIER ::= { bootParams 4 } tftpServerName OBJECT-TYPE SYNTAX HostNameOrIpAddr MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the TFTP server from which to read or write the device's configuration files or from which to read a firmware image. The value of this object can be a fully- or partially-qualified domain name system (dns) name, or it can be an ip address in the familiar 'dotted-quad' notation. If the value of this object is a fully- or partially-qualified dns name, the device will attempt to use the Domain Name System to convert the name to an ip address before initiating a transaction with this TFTP server. This object may be set only if tftpAdminStatus has the value 'configure'." ::= { tftpGroup 1 } tftpUserName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The user name that makes the TFTP request. This object may be set only if tftpAdminStatus has the value 'configure'." ::= { tftpGroup 2 } tftpRemoteFileName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The file name of the file on the remote TFTP server. This object may be set only if tftpAdminStatus has the value 'configure'." ::= { tftpGroup 3 } tftpLocalFileName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..63)) MAX-ACCESS read-write STATUS current DESCRIPTION "The local file name of the file which is copied to or from the remote server. If this string is a 0 length string, then the value of tftpRemoteFileName shall also be used as the local file name. This object may be set only if tftpAdminStatus has the value 'configure'." ::= { tftpGroup 4 } tftpOperation OBJECT-TYPE SYNTAX INTEGER { putFile(1), getFile(2), getFirmware(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When tftpOperation has the value putFile(1) when tftpAdminStatus is set to 'execute', the device attempts to copy the file identified by tftpLocalFileName to the file tfptRemoteFileName. When tftpOperation has the value getFile(2) when tftpAdminStatus is set to 'execute', the device attempts to copy the file identified by tftpRemoteFileName on the remote tftp server to the file identified by tftpLocalFileName. When tftpOperation has the value getFirmware(3) when tftpAdminStatus is set to 'execute', the device attempts to replace its firmware image with the file identified by tftpRemoteFileName. This firmware file will be used the next time the system is reset. When tftpOperation has the value putConfig(1) when tftpAdminStatus is set to 'execute', the device attempts to copy the file identified by tftpLocalFileName to the file tfptRemoteFileName. When tftpOperation has the value getConfig(2) when tftpAdminStatus is set to 'execute', the device attempts to copy the file identified by tftpRemoteFileName on the remote tftp server to the file identified by tftpLocalFileName. " ::= { tftpGroup 5 } tftpAdminState OBJECT-TYPE SYNTAX INTEGER { configure(1), execute(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to initiate a file transfer using the TFTP protocol between the local system and a remote TFTP server identified by tftpServerAddr. The file name on the remote server is identified by tftpRemoteFileName and the local file name is identified by tftpLocalFileName. The tftp operation is identified by the valu of tftpOperation. The objects tftpServerName, tftpUserName, tftpLocalFileName, tftpRemoteFileName, and tftpOperation may only be set when tftpAdminState has the value 'configure'. When tftpAdminState is set to 'execute', the operation identified by tftpOperation shall be started and the state of the operation is reflected in tftpOperationState. Setting this attribute to 'execute' when tftpOperationState is not 'inactive' has no effect on the operational state. Under normal operation tftpAdminState should only be set to 'configure' if tftpOperationState is not 'executing'. If tftpOperationState is 'executing' then the system may attempt to abort the current opertion and change the operation state to 'inactive' or not permitting the set to occur by returning the snmp error 'inconsistentValue'." ::= { tftpGroup 6 } tftpOperationState OBJECT-TYPE SYNTAX INTEGER { inactive(1), executing(2), succeeded(3), localFileProblem(4), unknownHost(5), timedOut(6), remoteFileProblem(7), otherFailure(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value 'executing' reflects a transition of tftpAdminState from 'configure' to 'execute'. In the 'executing' state, the TFTP operation identified by the value of tftpOperation shall begin with the values for the objects tftpServerName, tftpUserName, tftpRemoteFileName, and tftpLocalFileName. When the TFTP operation has completed successfully, the value of tftpOperation shall be set to 'succeeded'. If the operation failed, the value shall be set to one of 'localFileProblem', 'unknownHost', 'timedOut', 'remoteFileProblem', or 'otherFailure'. Any state transition shall result in setting the tftpOperationStateChange object." ::= { tftpGroup 7 } tftpOperationStateChange OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "This is the value of sysUpTime when the value of tftpOperationState changes." ::= { tftpGroup 8 } tftpErrorMessage OBJECT-TYPE SYNTAX DisplayString(SIZE(0..127)) MAX-ACCESS read-only STATUS current DESCRIPTION "An error message giving a brief description of the error if the tftpOperation did not succeed." ::= { tftpGroup 9 } END