librenms-librenms/tests/Feature/SnmpTraps/AdvaNetworkElementAlmTrapTest.php
Tony Murray 26318dc4b3 Improve trap testing (#14546)
* Improve trap testing
Add helper log() to Trap
Avoid saving to the database at all

* style

* Move all traps to $trap->log()

* Update tests

* Lint and style fixes

* Use correct partial mock call

* more style

* Add docs

* debug in ci

* use the correct log function....................

* all, I guess

* not the first??

* 3rd?

* use event_id to order
2022-11-05 14:43:54 -05:00

146 lines
6.4 KiB
PHP

<?php
/**
* AdvaNetworkElementAlmTest.php
*
* -Description-
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <https://www.gnu.org/licenses/>.
*
* @link https://www.librenms.org
*
* @copyright 2019 Heath Barnhart
* @author Heath Barnhart <hbarnhart@kanren.net>
*/
namespace LibreNMS\Tests\Feature\SnmpTraps;
class AdvaNetworkElementAlmTrapTest extends SnmpTrapTestCase
{
public function testElementAlarmCleared(): void
{
$this->assertTrapLogsMessage(<<<'TRAP'
{{ hostname }}
UDP: [{{ ip }}]:57602->[192.168.5.5]:162
DISMAN-EVENT-MIB::sysUpTimeInstance 26:19:43:37.24
SNMPv2-MIB::snmpTrapOID.0 CM-ALARM-MIB::cmNetworkElementAlmTrap
CM-ALARM-MIB::cmAlmIndex.0 30
CM-ALARM-MIB::cmNetworkElementAlmNotifCode.1.30 cleared
CM-ALARM-MIB::cmNetworkElementAlmType.1.30 lnkdown
CM-ALARM-MIB::cmNetworkElementAlmSrvEff.1.30 serviceAffecting
CM-ALARM-MIB::cmNetworkElementAlmTime.1.30 2018-12-10,11:1:43.0,-6:0
CM-ALARM-MIB::cmNetworkElementAlmLocation.1.30 nearEnd
CM-ALARM-MIB::cmNetworkElementAlmDirection.1.30 receiveDirectionOnly
CM-ALARM-MIB::cmNetworkElementAlmDescr.1.30 "Test Alarm Cleared"
CM-ALARM-MIB::cmNetworkElementAlmObject.1.30 CM-FACILITY-MIB::cmEthernetNetPortIndex.1.1.1.2
CM-ALARM-MIB::cmNetworkElementAlmObjectName.1.30 NETWORK PORT-1-1-1-2
CM-ALARM-MIB::cmNetworkElementAlmAdditionalInfoObject.1.30 SNMPv2-SMI::zeroDotZero
CM-ALARM-MIB::cmNetworkElementAlmAdditionalInfoName.1.30
RMON2-MIB::probeDateTime.0 "07 E2 0C 0A 0B 01 2B 00 2D 06 00 "
ADVA-MIB::neEventLogIndex.231 231
ADVA-MIB::neEventLogTimeStamp.231 2018-12-10,11:1:43.3,-6:0
TRAP,
'Alarming Element: NETWORK PORT-1-1-1-2 Description: Test Alarm Cleared Severity: cleared',
'Could not handle cmNetworkElementAlmTrap cleared',
[1],
);
}
public function testElementAlarmMinor(): void
{
$this->assertTrapLogsMessage(<<<'TRAP'
{{ hostname }}
UDP: [{{ ip }}]:57602->[192.168.5.5]:162
DISMAN-EVENT-MIB::sysUpTimeInstance 26:19:43:37.24
SNMPv2-MIB::snmpTrapOID.0 CM-ALARM-MIB::cmNetworkElementAlmTrap
CM-ALARM-MIB::cmAlmIndex.0 30
CM-ALARM-MIB::cmNetworkElementAlmNotifCode.1.30 minor
CM-ALARM-MIB::cmNetworkElementAlmType.1.30 lnkdown
CM-ALARM-MIB::cmNetworkElementAlmSrvEff.1.30 serviceAffecting
CM-ALARM-MIB::cmNetworkElementAlmTime.1.30 2018-12-10,11:1:43.0,-6:0
CM-ALARM-MIB::cmNetworkElementAlmLocation.1.30 nearEnd
CM-ALARM-MIB::cmNetworkElementAlmDirection.1.30 receiveDirectionOnly
CM-ALARM-MIB::cmNetworkElementAlmDescr.1.30 "Test Alarm Minor"
CM-ALARM-MIB::cmNetworkElementAlmObject.1.30 CM-FACILITY-MIB::cmEthernetNetPortIndex.1.1.1.2
CM-ALARM-MIB::cmNetworkElementAlmObjectName.1.30 NETWORK PORT-1-1-1-2
CM-ALARM-MIB::cmNetworkElementAlmAdditionalInfoObject.1.30 SNMPv2-SMI::zeroDotZero
CM-ALARM-MIB::cmNetworkElementAlmAdditionalInfoName.1.30
RMON2-MIB::probeDateTime.0 "07 E2 0C 0A 0B 01 2B 00 2D 06 00 "
ADVA-MIB::neEventLogIndex.231 231
ADVA-MIB::neEventLogTimeStamp.231 2018-12-10,11:1:43.3,-6:0
TRAP,
'Alarming Element: NETWORK PORT-1-1-1-2 Description: Test Alarm Minor Severity: minor',
'Could not handle cmNetworkElementAlmTrap minor',
[3],
);
}
public function testElementAlarmMajor(): void
{
$this->assertTrapLogsMessage(<<<'TRAP'
{{ hostname }}
UDP: [{{ ip }}]:57602->[192.168.5.5]:162
DISMAN-EVENT-MIB::sysUpTimeInstance 26:19:43:37.24
SNMPv2-MIB::snmpTrapOID.0 CM-ALARM-MIB::cmNetworkElementAlmTrap
CM-ALARM-MIB::cmAlmIndex.0 30
CM-ALARM-MIB::cmNetworkElementAlmNotifCode.1.30 major
CM-ALARM-MIB::cmNetworkElementAlmType.1.30 lnkdown
CM-ALARM-MIB::cmNetworkElementAlmSrvEff.1.30 serviceAffecting
CM-ALARM-MIB::cmNetworkElementAlmTime.1.30 2018-12-10,11:1:43.0,-6:0
CM-ALARM-MIB::cmNetworkElementAlmLocation.1.30 nearEnd
CM-ALARM-MIB::cmNetworkElementAlmDirection.1.30 receiveDirectionOnly
CM-ALARM-MIB::cmNetworkElementAlmDescr.1.30 "Test Alarm Major"
CM-ALARM-MIB::cmNetworkElementAlmObject.1.30 CM-FACILITY-MIB::cmEthernetNetPortIndex.1.1.1.2
CM-ALARM-MIB::cmNetworkElementAlmObjectName.1.30 NETWORK PORT-1-1-1-2
CM-ALARM-MIB::cmNetworkElementAlmAdditionalInfoObject.1.30 SNMPv2-SMI::zeroDotZero
CM-ALARM-MIB::cmNetworkElementAlmAdditionalInfoName.1.30
RMON2-MIB::probeDateTime.0 "07 E2 0C 0A 0B 01 2B 00 2D 06 00 "
ADVA-MIB::neEventLogIndex.231 231
ADVA-MIB::neEventLogTimeStamp.231 2018-12-10,11:1:43.3,-6:0
TRAP,
'Alarming Element: NETWORK PORT-1-1-1-2 Description: Test Alarm Major Severity: major',
'Could not handle cmNetworkElementAlmTrap major',
[4],
);
}
public function testElementAlarmCritical(): void
{
$this->assertTrapLogsMessage(<<<'TRAP'
{{ hostname }}
UDP: [{{ ip }}]:57602->[192.168.5.5]:162
DISMAN-EVENT-MIB::sysUpTimeInstance 26:19:43:37.24
SNMPv2-MIB::snmpTrapOID.0 CM-ALARM-MIB::cmNetworkElementAlmTrap
CM-ALARM-MIB::cmAlmIndex.0 30
CM-ALARM-MIB::cmNetworkElementAlmNotifCode.1.30 critical
CM-ALARM-MIB::cmNetworkElementAlmType.1.30 lnkdown
CM-ALARM-MIB::cmNetworkElementAlmSrvEff.1.30 serviceAffecting
CM-ALARM-MIB::cmNetworkElementAlmTime.1.30 2018-12-10,11:1:43.0,-6:0
CM-ALARM-MIB::cmNetworkElementAlmLocation.1.30 nearEnd
CM-ALARM-MIB::cmNetworkElementAlmDirection.1.30 receiveDirectionOnly
CM-ALARM-MIB::cmNetworkElementAlmDescr.1.30 "Test Alarm Critical"
CM-ALARM-MIB::cmNetworkElementAlmObject.1.30 CM-FACILITY-MIB::cmEthernetNetPortIndex.1.1.1.2
CM-ALARM-MIB::cmNetworkElementAlmObjectName.1.30 NETWORK PORT-1-1-1-2
CM-ALARM-MIB::cmNetworkElementAlmAdditionalInfoObject.1.30 SNMPv2-SMI::zeroDotZero
CM-ALARM-MIB::cmNetworkElementAlmAdditionalInfoName.1.30
RMON2-MIB::probeDateTime.0 "07 E2 0C 0A 0B 01 2B 00 2D 06 00 "
ADVA-MIB::neEventLogIndex.231 231
ADVA-MIB::neEventLogTimeStamp.231 2018-12-10,11:1:43.3,-6:0
TRAP,
'Alarming Element: NETWORK PORT-1-1-1-2 Description: Test Alarm Critical Severity: critical',
'Could not handle cmNetworkElementAlmTrap critical',
[5],
);
}
}