Files
librenms-librenms/mibs/adva/F3-NTP-MIB
MaxPecc afb7a61793 Added support of new OS for NTP/PTP systems: Meinberg OS, Safran (Orolia), Oscilloquartz (Adva) (#15453)
* Added support of new OS for NTP/PTP systems:
- support of Meinberg microSync OS (mbg-meinbergos)
- support of Safran (Orolia) SecureSync OS (orolia-securesync)
- support of Adva OSA (5401 and 5412) OS (adva_fsp150cm)

* Fix Safran (Orolia) images

* Added Test-unit JSON files

* Changed SVG images

* Changed SVG images

* Changed SVG images
2023-12-03 00:36:31 +01:00

3083 lines
116 KiB
Plaintext
Raw Permalink Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
F3-NTP-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
MODULE-IDENTITY, OBJECT-TYPE, IpAddress, Integer32, Unsigned32
FROM SNMPv2-SMI
DisplayString, TruthValue, RowStatus, StorageType, VariablePointer,DateAndTime,
TEXTUAL-CONVENTION
FROM SNMPv2-TC
neIndex, shelfIndex, slotIndex
FROM CM-ENTITY-MIB
fsp150cm
FROM ADVA-MIB
AdminState, OperationalState, SecondaryState, F3DisplayString,
IpVersion, CmPmIntervalType, CmPmBinAction, PerfCounter64
FROM CM-COMMON-MIB
CmNtpMode, CmNtpType
FROM CM-SYSTEM-MIB
cmEthernetAccPortIndex, cmEthernetNetPortIndex
FROM CM-FACILITY-MIB
Ipv6Address
FROM IPV6-TC;
f3NtpMIB MODULE-IDENTITY
LAST-UPDATED "202212260000Z"
ORGANIZATION "ADVA Optical Networking"
CONTACT-INFO
"Web URL: http://adva.com/
E-mail: support@adva.com
Postal: ADVA Optical Networking SE
Campus Martinsried
Fraunhoferstrasse 9a
82152 Martinsried/Munich
Germany
Phone: +49 089 89 06 65 0
Fax: +49 089 89 06 65 199 "
DESCRIPTION "This module defines the NTP definitions used by
the F3 (FSP150CM/CC) product lines.
SNMP Tables in this module: f3NtpClockTable,f3NCITable,f3NtpVirtualPort,
f3NtpRemoteClientTable,f3NtpAccPortFlowPointTable,
f3NtpNetPortFlowPointTable,f3NCIStatsTable,
f3NCIHistoryTable,f3NCIThresholdTable,
f3NtpAccPortFlowPointStatsTable,f3NtpAccPortFlowPointHistoryTable,
f3NtpAccPortFlowPointThresholdTable,
f3NtpNetPortFlowPointStatsTable,f3NtpNetPortFlowPointHistoryTable,
f3NtpNetPortFlowPointThresholdTable,
f3NtpTrackedClientTable, f3NtpTrackedClientStatsTable,
f3NtpTrackedClientHistoryTable,f3NtpTrackedClientThresholdTable,
f3NtpRemoteServerTable.
Copyright (C) ADVA."
REVISION "202208250000Z"
DESCRIPTION
"
Notes from release 202212260000Z
a) Changed f3NtpClockOffset units to PerfCounter64
Notes from release 202208250000Z
a) Added new enum:
NtpPollingInterval
Notes from release 202208080000Z
a) Added new table:
f3NtpRemoteServer
Notes from release 202208030000Z
a) f3NtpClockEntry has new attributes:
f3NtpClockOffset
f3NtpClockSecondaryState
Notes from release 202205190000Z
a) added new tables to NCI:
f3NtpTrackedClientStatsTable
f3NtpTrackedClientHistoryTable
f3NtpTrackedClientThresholdTable
b) added new notification to NCI:
f3NtpTrackedClientCrossingAlert
c) added new oid definition:
f3NtpPerformanceNotifications
Notes from release 202205090000Z
a) added new table to NCI:
f3NtpTrackedClientTable
Notes from release 202204220000Z
a) f3NCITable has new attributes:
f3NCINtpHardenedResponderControl
Notes from release 202204210000Z
a) F3NCIStatsEntry has new attributes:
f3NCIStatsAuthFailures
f3NCIStatsReqsDiscarded
f3NCIStatsAvgTPS
f3NCIStatsMaxTPS
b) F3NCIHistoryEntry has new attributes:
f3NCIHistoryAuthFailures
f3NCIHistoryReqsDiscarded
f3NCIHistoryAvgTPS
f3NCIHistoryMaxTPS
Notes from release 202103220000Z
a)Added the literals local(3) and gps(4) to NtpTimeScale.
b) added f3NCITimeScale and f3NCICurrentTimeOfDay scalar variable
c) Change f3NtpClockTimeScale scalar variable to deprecated
Notes from release 201912300000Z
a) f3NCITable has new attributes:
f3NtpAutokeyCtrl,
Notes from release 201909260000Z
a) f3NCITable has new attributes:
f3NCIDaytimeServiceControl,
f3NCITimeServiceControl
Notes from release 201908260000Z
a) New Textual Conventions :
NtpAssociationMode
b) f3NCITable has new attributes:
f3NCIAssociationMode,
f3NCIPeer1IpV4Address,
f3NCIPeer2IpV4Address,
f3NCIPeer3IpV4Address,
f3NCIPeer1IpV6Address,
f3NCIPeer2IpV6Address,
f3NCIPeer3IpV6Address,
f3NCIPeerMinInterval,
f3NCIPeerMaxInterval,
f3NCIPeerSymKeyIdList
Notes from release 201906270000Z
a) New Textual Conventions :
NtpBroadcastInterval and NtpVersion
b) f3NCITable has new attributes:
f3NCIBroadcastState,
f3NCIBroadcastIpV4Address,
f3NCIBroadcastIpV6Address,
f3NCIBroadcastInterval,
f3NCIBroadcastMaxHops,
f3NCIBroadcastSymKeyId,
f3NCIBroadcastNtpVersion
Notes from release 201902040000Z
a) f3NCITable has new attributes:
f3NCIDefaultGatewayControl
Notes from release 201804280000Z
a) f3NCITable has new attributes:
f3NCIIpV6UdpChecksum,
f3NCIIpV6Address,
f3NCIIpV6AddrPrefixLength,
f3NCIIpV4Gateway,
f3NCIIpV6Gateway
Notes from release 201610260000Z
a) f3NtpRemoteClientTable has been changed:
Attributes with Unsigned32 syntax:
f3NtpRemoteClientRxPacketsLo,
f3NtpRemoteClientRxPacketsHi,
f3NtpRemoteClientAvgPollIntervalLo,
f3NtpRemoteClientAvgPollIntervalHi,
f3NtpRemoteClientLastPollIntervalLo,
f3NtpRemoteClientLastPollIntervalHi
have been replaced by ones with PerfCounter64 syntax:
f3NtpRemoteClientRxPackets,
f3NtpRemoteClientAvgPollInterval,
f3NtpRemoteClientLastPollInterval
Notes from release 201607120000Z
First version."
::= {fsp150cm 47}
--
-- OID definitions
--
f3NtpObjects OBJECT IDENTIFIER ::= {f3NtpMIB 1}
f3NtpConformance OBJECT IDENTIFIER ::= {f3NtpMIB 2}
f3NtpPerformanceObjects OBJECT IDENTIFIER ::= {f3NtpMIB 3}
f3NtpPerformanceNotifications OBJECT IDENTIFIER ::= {f3NtpMIB 4}
--
-- Textual Conventions
--
NtpFlowPointType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Enumerations for NTP Flow Point Type. Other enumeration values
will be defined in the future. Presently only case is:
server - represents a NTP Server Type."
SYNTAX INTEGER {
server(1)
}
NtpTimeScale ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Enumerations for Time Scale,
utc, not-available, local, gps."
SYNTAX INTEGER {
utc(1),
not-available(2),
local(3),
gps(4)
}
ToggleValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Enumerations for functionality that can be enabled or disabled."
SYNTAX INTEGER {
enabled(1),
disabled(2),
not-available(3)
}
GnssSyncLossAction ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Enumerations for specifying an action that a manager can execute."
SYNTAX INTEGER {
strtm-16-li-nochg(1),
strtm-16-li-unkn(2),
strtm-1-li-unkn(3),
none(4),
not-available(5)
}
NtpBroadcastInterval ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Enumerations for NTP Broadcast Interval."
SYNTAX INTEGER {
pkt1per8secs(1),
pkt1per16secs(2),
pkt1per32secs(3),
pkt1per64secs(4),
pkt1per128secs(5),
pkt1per256secs(6),
pkt1per512secs(7),
pkt1per1024secs(8),
pkt1per2048secs(9),
pkt1per4096secs(10),
pkt1per8192secs(11),
pkt1per16384secs(12),
pkt1per32768secs(13),
pkt1per65536secs(14)
}
NtpVersion ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Enumerations for NTP Version."
SYNTAX INTEGER {
ntpv3(1),
ntpv4(2)
}
NtpAssociationType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Enumerations for NTP Association Type."
SYNTAX INTEGER {
not-available(1),
symmetric-active(2),
symmetric-passive(3),
server-only(4)
}
NtpPollingInterval ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Enumerations for NTP Polling Interval."
SYNTAX INTEGER {
sec16(1),
sec32(2),
sec64(3),
sec128(4),
sec256(5),
sec512(6),
sec1024(7)
}
--
-- NTP Clock Table
--
f3NtpClockTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NtpClockEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of entries corresponding to the NTP Clock entities."
::= { f3NtpObjects 1 }
f3NtpClockEntry OBJECT-TYPE
SYNTAX F3NtpClockEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry containing information applicable to a particular
NTP Clock entity."
INDEX { neIndex, f3NtpClockIndex }
::= { f3NtpClockTable 1 }
F3NtpClockEntry ::=
SEQUENCE {
f3NtpClockIndex Integer32,
f3NtpClockAlias DisplayString,
f3NtpClockAdminState AdminState,
f3NtpClockOperationalState OperationalState,
f3NtpClockTimeClock VariablePointer,
f3NtpClockStratumLevel Unsigned32,
f3NtpClockLeapIndicator Unsigned32,
f3NtpClockTimeScale DisplayString,
f3NtpClockPrecision Unsigned32,
f3NtpClockRootDelay Unsigned32,
f3NtpClockRootDispersion Unsigned32,
f3NtpClockNtpMode CmNtpMode,
f3NtpClockNtpType CmNtpType,
f3NtpClockNtpAuthentication ToggleValue,
f3NtpClockServerState ToggleValue,
f3NtpClockTimeReferenceLossHandling GnssSyncLossAction,
f3NtpClockRefClockId DisplayString,
f3NtpClockStorageType StorageType,
f3NtpClockRowStatus RowStatus,
f3NtpAuthenticationSecureMode ToggleValue,
f3NtpAutokeyCtrl ToggleValue,
f3NtpClockOffset PerfCounter64,
f3NtpClockSecondaryState SecondaryState
}
f3NtpClockIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique index value associated with the NTP Clock Entity."
::= { f3NtpClockEntry 1 }
f3NtpClockAlias OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..256))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows SNMP management entities to provide an
alias to the NTP Clock entity."
::= { f3NtpClockEntry 2 }
f3NtpClockAdminState OBJECT-TYPE
SYNTAX AdminState
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object represents the Administrative State of the NTP Clock."
::= { f3NtpClockEntry 3 }
f3NtpClockOperationalState OBJECT-TYPE
SYNTAX OperationalState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object represents the Operational State of the NTP Clock."
::= { f3NtpClockEntry 4 }
f3NtpClockTimeClock OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object provides the entry from f3TimeClockTable, which is used as frequency and time of day source for the NTP Clock."
::= { f3NtpClockEntry 5 }
f3NtpClockStratumLevel OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Ntp Stratum Level of the NTP Clock."
::= { f3NtpClockEntry 6 }
f3NtpClockLeapIndicator OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Leap Second indicator if a leap second will occur."
::= { f3NtpClockEntry 7 }
f3NtpClockTimeScale OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Indicates whether the time source is UTC time or not."
::= { f3NtpClockEntry 8 }
f3NtpClockPrecision OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Todo."
::= { f3NtpClockEntry 9 }
f3NtpClockRootDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Todo."
::= { f3NtpClockEntry 10 }
f3NtpClockRootDispersion OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Todo."
::= { f3NtpClockEntry 11 }
f3NtpClockNtpMode OBJECT-TYPE
SYNTAX CmNtpMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the current NTP mode of the NTP clock."
::= { f3NtpClockEntry 12 }
f3NtpClockNtpType OBJECT-TYPE
SYNTAX CmNtpType
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Todo."
::= { f3NtpClockEntry 13 }
f3NtpClockNtpAuthentication OBJECT-TYPE
SYNTAX ToggleValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Permits to enable or disable NTP Authentication."
::= { f3NtpClockEntry 14 }
f3NtpClockServerState OBJECT-TYPE
SYNTAX ToggleValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Permits to enable or disable the NTP Clock as Ntp Server."
::= { f3NtpClockEntry 15 }
f3NtpClockTimeReferenceLossHandling OBJECT-TYPE
SYNTAX GnssSyncLossAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Todo."
::= { f3NtpClockEntry 16 }
f3NtpClockRefClockId OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies the NTP Clock by a string."
::= { f3NtpClockEntry 17 }
f3NtpClockStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of storage configured for this entry."
::= { f3NtpClockEntry 18 }
f3NtpClockRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The status of this row. An entry MUST NOT exist in the
active state unless all objects in the entry have an
appropriate value, as described
in the description clause for each writable object.
The values of f3NtpClockRowStatus supported are
createAndGo(4) and destroy(6). All mandatory attributes
must be specified in a single SNMP SET request with
f3NtpClockRowStatus value as createAndGo(4).
Upon successful row creation, this object has a
value of active(1).
The f3NtpClockRowStatus object may be modified if
the associated instance of this object is equal to active(1)."
::= { f3NtpClockEntry 19 }
f3NtpAuthenticationSecureMode OBJECT-TYPE
SYNTAX ToggleValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Allows to enable or disable NTP Authentication Secure Mode."
::= { f3NtpClockEntry 20 }
f3NtpAutokeyCtrl OBJECT-TYPE
SYNTAX ToggleValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Allows to enable or disable NTP Clock Server Auto Key."
::= { f3NtpClockEntry 21 }
f3NtpClockOffset OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This attribute indicates estimated time offset to the reference clock in ns"
::= { f3NtpClockEntry 22 }
f3NtpClockSecondaryState OBJECT-TYPE
SYNTAX SecondaryState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object represents the Secondary State of the NTP Clock."
::= { f3NtpClockEntry 23 }
--
-- NTP Clock Interface Table
--
f3NCITable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NCIEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of entries corresponding to NTP Clock Interface (NCI) entities."
::= { f3NtpObjects 2 }
f3NCIEntry OBJECT-TYPE
SYNTAX F3NCIEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry containing information applicable to a particular NTP Clock Interface."
INDEX { neIndex, f3NtpClockIndex, f3NCIIndex }
::= { f3NCITable 1 }
F3NCIEntry ::=
SEQUENCE {
f3NCIIndex Integer32,
f3NCIAlias DisplayString,
f3NCIAdminState AdminState,
f3NCIOperationalState OperationalState,
f3NCIIfName DisplayString,
f3NCIIpProtocol IpVersion,
f3NCIIpV4Address IpAddress,
f3NCIIpV4SubnetMask IpAddress,
f3NCIDscp Unsigned32,
f3NCIStorageType StorageType,
f3NCIRowStatus RowStatus,
f3NCIIpV6UdpChecksum ToggleValue,
f3NCIIpV6Address Ipv6Address,
f3NCIIpV6AddrPrefixLength Integer32,
f3NCIIpV4Gateway IpAddress,
f3NCIIpV6Gateway Ipv6Address,
f3NCIDefaultGatewayControl ToggleValue,
f3NCIDaytimeServiceControl ToggleValue,
f3NCITimeServiceControl ToggleValue,
f3NCIBroadcastState ToggleValue,
f3NCIBroadcastIpV4Address IpAddress,
f3NCIBroadcastIpV6Address Ipv6Address,
f3NCIBroadcastInterval NtpBroadcastInterval,
f3NCIBroadcastMaxHops Integer32,
f3NCIBroadcastSymKeyId Integer32,
f3NCIBroadcastNtpVersion NtpVersion,
f3NCIAssociationMode NtpAssociationType,
f3NCIPeer1IpV4Address IpAddress,
f3NCIPeer2IpV4Address IpAddress,
f3NCIPeer3IpV4Address IpAddress,
f3NCIPeer1IpV6Address Ipv6Address,
f3NCIPeer2IpV6Address Ipv6Address,
f3NCIPeer3IpV6Address Ipv6Address,
f3NCIPeerMinInterval NtpBroadcastInterval,
f3NCIPeerMaxInterval NtpBroadcastInterval,
f3NCIPeerSymKeyIdList DisplayString,
f3NCITimeScale NtpTimeScale,
f3NCICurrentTimeOfDay DateAndTime,
f3NCINtpHardenedResponderControl ToggleValue
}
f3NCIIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique index value associated with the NTP Clock Interface."
::= { f3NCIEntry 1 }
f3NCIAlias OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..256))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows SNMP management entities to provide an
alias to the NTP Clock Interface entity."
::= { f3NCIEntry 2 }
f3NCIAdminState OBJECT-TYPE
SYNTAX AdminState
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object represents the Administrative State of the NTP Clock Interface."
::= { f3NCIEntry 3 }
f3NCIOperationalState OBJECT-TYPE
SYNTAX OperationalState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object represents the Operational State of the NTP Clock Interface."
::= { f3NCIEntry 4 }
f3NCIIfName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows SNMP management entities to provide a
name to the NTP Clock Interface. This is used for creation of the
underlying IP Interface associated with the NTP Clock Interface."
::= { f3NCIEntry 5 }
f3NCIIpProtocol OBJECT-TYPE
SYNTAX IpVersion
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of the IP Protocol to communicate with associated NTP Clock."
::= { f3NCIEntry 6 }
f3NCIIpV4Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of the IPv4 Address of the NTP Clock."
::= { f3NCIEntry 7 }
f3NCIIpV4SubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of the IPv4 Subnet Mask of the NTP Clock."
::= { f3NCIEntry 8 }
f3NCIDscp OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object represents Differenciated Services Code Point, its value is set into DS field in the IP header of IP packets."
::= { f3NCIEntry 9 }
f3NCIStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of storage configured for this entry."
::= { f3NCIEntry 10 }
f3NCIRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The status of this row. An entry MUST NOT exist in the
active state unless all objects in the entry have an
appropriate value, as described
in the description clause for each writable object.
The values of f3NCIRowStatus supported are
createAndGo(4) and destroy(6). All mandatory attributes
must be specified in a single SNMP SET request with
f3NCIRowStatus value as createAndGo(4).
Upon successful row creation, this object has a
value of active(1).
The f3NCIRowStatus object may be modified if
the associated instance of this object is equal to active(1)."
::= { f3NCIEntry 11 }
f3NCIIpV6UdpChecksum OBJECT-TYPE
SYNTAX ToggleValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows to enable/disable insertion of checksum on
transmit side of NTP packet and to ignore it on received side.
This object has an impact only on NTP Clock Interface with
IPv6 address."
::= { f3NCIEntry 12 }
f3NCIIpV6Address OBJECT-TYPE
SYNTAX Ipv6Address
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows specification of the IPv6 Address of
the NTP Clock Interface."
::= { f3NCIEntry 13 }
f3NCIIpV6AddrPrefixLength OBJECT-TYPE
SYNTAX Integer32 (0..128)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows specification of the IPv6 address prefix length of
the NTP Clock Interface."
::= { f3NCIEntry 14 }
f3NCIIpV4Gateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows to specify IPv4 gateway."
::= { f3NCIEntry 15 }
f3NCIIpV6Gateway OBJECT-TYPE
SYNTAX Ipv6Address
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows to specify IPv6 gateway."
::= { f3NCIEntry 16 }
f3NCIDefaultGatewayControl OBJECT-TYPE
SYNTAX ToggleValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute controls Gateway address for NTP Clock Interface."
::= { f3NCIEntry 17 }
f3NCITimeServiceControl OBJECT-TYPE
SYNTAX ToggleValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute controls the Time service for NTP Clock Interface."
::= { f3NCIEntry 18 }
f3NCIDaytimeServiceControl OBJECT-TYPE
SYNTAX ToggleValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute controls the Daytime service for NTP Clock Interface."
::= { f3NCIEntry 19 }
f3NCIBroadcastState OBJECT-TYPE
SYNTAX ToggleValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the use of NTP broadcasting."
::= { f3NCIEntry 20 }
f3NCIBroadcastIpV4Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows specification of the Broadcast IPv4 Address of
the NTP Clock Interface."
::= { f3NCIEntry 21 }
f3NCIBroadcastIpV6Address OBJECT-TYPE
SYNTAX Ipv6Address
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows specification of the Broadcast IPv6 Address of
the NTP Clock Interface."
::= { f3NCIEntry 22 }
f3NCIBroadcastInterval OBJECT-TYPE
SYNTAX NtpBroadcastInterval
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows specification of the Broadcast Interval time of
the NTP Clock Interface."
::= { f3NCIEntry 23 }
f3NCIBroadcastMaxHops OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows specification of the Max of Hops for broadcasting
of the NTP Clock Interface."
::= { f3NCIEntry 24 }
f3NCIBroadcastSymKeyId OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows specification of the Symmetric key Id for
broadcasting of the NTP Clock Interface."
::= { f3NCIEntry 25 }
f3NCIBroadcastNtpVersion OBJECT-TYPE
SYNTAX NtpVersion
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows specification of the Ntp Version that is used
for the NTP Clock Interface."
::= { f3NCIEntry 26 }
f3NCIAssociationMode OBJECT-TYPE
SYNTAX NtpAssociationType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows specification of the Ntp Association Mode that is used
for the NTP Clock Interface."
::= { f3NCIEntry 27 }
f3NCIPeer1IpV4Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IPv4 Address of the first peer of the NTP Clock Interface.
If NTP Association Mode is symmetric-active, then symmetric-passive peer addresses
can be specified.
But a maximum of three symmetric-passive peers can be specified per NTP Clock.
If NTP Association Mode is symmetric-passive, three symmetric-active peers can be
associated and read, but they are not specified."
::= { f3NCIEntry 28 }
f3NCIPeer2IpV4Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IPv4 Address of the second peer of the NTP Clock Interface.
If NTP Association Mode is symmetric-active, then symmetric-passive peer addresses
can be specified.
But a maximum of three symmetric-passive peers can be specified per NTP Clock.
If NTP Association Mode is symmetric-passive, three symmetric-active peers can be
associated and read, but they are not specified."
::= { f3NCIEntry 29 }
f3NCIPeer3IpV4Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IPv4 Address of the third peer of the NTP Clock Interface.
If NTP Association Mode is symmetric-active, then symmetric-passive peer addresses
can be specified.
But a maximum of three symmetric-passive peers can be specified per NTP Clock.
If NTP Association Mode is symmetric-passive, three symmetric-active peers can be
associated and read, but they are not specified."
::= { f3NCIEntry 30 }
f3NCIPeer1IpV6Address OBJECT-TYPE
SYNTAX Ipv6Address
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IPv6 Address of the first peer of the NTP Clock Interface.
If NTP Association Mode is symmetric-active, then symmetric-passive peer addresses
can be specified.
But a maximum of three symmetric-passive peers can be specified per NTP Clock.
If NTP Association Mode is symmetric-passive, three symmetric-active peers can be
associated and read, but they are not specified."
::= { f3NCIEntry 31 }
f3NCIPeer2IpV6Address OBJECT-TYPE
SYNTAX Ipv6Address
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IPv6 Address of the second peer of the NTP Clock Interface.
If NTP Association Mode is symmetric-active, then symmetric-passive peer addresses
can be specified.
But a maximum of three symmetric-passive peers can be specified per NTP Clock.
If NTP Association Mode is symmetric-passive, three symmetric-active peers can be
associated and read, but they are not specified."
::= { f3NCIEntry 32 }
f3NCIPeer3IpV6Address OBJECT-TYPE
SYNTAX Ipv6Address
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IPv6 Address of the third peer of the NTP Clock Interface.
If NTP Association Mode is symmetric-active, then symmetric-passive peer addresses
can be specified.
But a maximum of three symmetric-passive peers can be specified per NTP Clock.
If NTP Association Mode is symmetric-passive, three symmetric-active peers can be
associated and read, but they are not specified."
::= { f3NCIEntry 33 }
f3NCIPeerMinInterval OBJECT-TYPE
SYNTAX NtpBroadcastInterval
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows specification of the minimum of the peering Interval time of
the NTP Clock Interface."
::= { f3NCIEntry 34 }
f3NCIPeerMaxInterval OBJECT-TYPE
SYNTAX NtpBroadcastInterval
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows specification of the maximum of the peering Interval time of
the NTP Clock Interface."
::= { f3NCIEntry 35 }
f3NCIPeerSymKeyIdList OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Symmetric key IDs for peering with the NTP Clock Interface.
If NTP Association Mode is symmetric-active, then one key must be defined.
If NTP Association Mode is symmetric-passive, up to 20 symmetric keys can be specified,
each of them potentially matching the symmetric keys of a remote symmetric-active NCI."
::= { f3NCIEntry 36 }
f3NCITimeScale OBJECT-TYPE
SYNTAX NtpTimeScale
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute specifies Server time format."
::= { f3NCIEntry 37 }
f3NCICurrentTimeOfDay OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicate the Current time of day provided by the NC."
::= { f3NCIEntry 38 }
f3NCINtpHardenedResponderControl OBJECT-TYPE
SYNTAX ToggleValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute controls the NTP Hardened Responder for NTP Clock Interface."
::= { f3NCIEntry 39 }
--
-- NTP Virtual Port Table
--
f3NtpVirtualPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NtpVirtualPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of entries corresponding to NtpVirtualPortEntry entities."
::= { f3NtpObjects 3 }
f3NtpVirtualPortEntry OBJECT-TYPE
SYNTAX F3NtpVirtualPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry containing information applicable to a particular
NTP Virtual Port Entity."
INDEX { neIndex, shelfIndex, slotIndex, f3NtpVirtualPortIndex }
::= { f3NtpVirtualPortTable 1 }
F3NtpVirtualPortEntry ::=
SEQUENCE {
f3NtpVirtualPortIndex Integer32,
f3NtpVirtualPortAlias DisplayString,
f3NtpVirtualPortAdminState AdminState,
f3NtpVirtualPortOperationalState OperationalState,
f3NtpVirtualPortNtpFlowPoint VariablePointer,
f3NtpVirtualPortStorageType StorageType,
f3NtpVirtualPortRowStatus RowStatus
}
f3NtpVirtualPortIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique index value associated with the NTP Virtual Port Entity."
::= { f3NtpVirtualPortEntry 1 }
f3NtpVirtualPortAlias OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..256))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows SNMP management entities to provide an
alias to the NTP Virtual Port entity."
::= { f3NtpVirtualPortEntry 2 }
f3NtpVirtualPortAdminState OBJECT-TYPE
SYNTAX AdminState
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object represents the Administrative State of the NTP Virtual Port
Entity."
::= { f3NtpVirtualPortEntry 3 }
f3NtpVirtualPortOperationalState OBJECT-TYPE
SYNTAX OperationalState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object represents the Operational State of the NTP Virtual Port
Entity."
::= { f3NtpVirtualPortEntry 4 }
f3NtpVirtualPortNtpFlowPoint OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object associates the NTP Flow Point with the NTP Virtual Port."
::= { f3NtpVirtualPortEntry 5 }
f3NtpVirtualPortStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of storage configured for this entry."
::= { f3NtpVirtualPortEntry 6 }
f3NtpVirtualPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The status of this row. An entry MUST NOT exist in the
active state unless all objects in the entry have an
appropriate value, as described
in the description clause for each writable object.
The values of f3NtpVirtualPortRowStatus supported are
createAndGo(4) and destroy(6). All mandatory attributes
must be specified in a single SNMP SET request with
f3NtpVirtualPortRowStatus value as createAndGo(4).
Upon successful row creation, this object has a
value of active(1).
The f3NtpVirtualPortRowStatus object may be modified if
the associated instance of this object is equal to active(1)."
::= { f3NtpVirtualPortEntry 7 }
--
-- NTP Remote Client Table
--
f3NtpRemoteClientTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NtpRemoteClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of entries corresponding to NTP Remote Client entities."
::= { f3NtpObjects 4 }
f3NtpRemoteClientEntry OBJECT-TYPE
SYNTAX F3NtpRemoteClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry containing information applicable to a particular
NTP Remote Client Entity."
INDEX { neIndex, shelfIndex, slotIndex, f3NtpRemoteClientIndex }
::= { f3NtpRemoteClientTable 1 }
F3NtpRemoteClientEntry ::=
SEQUENCE {
f3NtpRemoteClientIndex Integer32,
f3NtpRemoteClientIpV4Address IpAddress,
f3NtpRemoteClientRxPackets PerfCounter64,
f3NtpRemoteClientAvgPollInterval PerfCounter64,
f3NtpRemoteClientLastPollInterval PerfCounter64,
f3NtpRemoteClientNtpMode Integer32,
f3NtpRemoteClientNtpVersion Integer32,
f3NtpRemoteClientStorageType StorageType,
f3NtpRemoteClientRowStatus RowStatus
}
f3NtpRemoteClientIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique index value associated with the NTP Remote Client Entity."
::= { f3NtpRemoteClientEntry 1 }
f3NtpRemoteClientIpV4Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object indicates the IPv4 Address of the NTP Remote Client."
::= { f3NtpRemoteClientEntry 2 }
f3NtpRemoteClientRxPackets OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object represents the number of NTP packets sent by the NTP Remote Client and received on the NTP Flow Point."
::= { f3NtpRemoteClientEntry 3 }
f3NtpRemoteClientAvgPollInterval OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object represents the interval over which monitored value has been the most recently sampled on the NTP Flow Point."
::= { f3NtpRemoteClientEntry 4 }
f3NtpRemoteClientLastPollInterval OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object represents the interval over which monitored value is sampled and averaged on the NTP Flow Point."
::= { f3NtpRemoteClientEntry 5 }
f3NtpRemoteClientNtpMode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object represents the NTP Mode of the NTP Remote Client."
::= { f3NtpRemoteClientEntry 6 }
f3NtpRemoteClientNtpVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object represents the NTP protocol Version used by the NTP Remote Client to communicate with the NTP Server."
::= { f3NtpRemoteClientEntry 7 }
f3NtpRemoteClientStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of storage configured for this entry."
::= { f3NtpRemoteClientEntry 8 }
f3NtpRemoteClientRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The status of this row. An entry MUST NOT exist in the
active state unless all objects in the entry have an
appropriate value, as described
in the description clause for each writable object.
The values of f3NtpRemoteClientRowStatus supported are
createAndGo(4) and destroy(6). All mandatory attributes
must be specified in a single SNMP SET request with
f3NtpRemoteClientRowStatus value as createAndGo(4).
Upon successful row creation, this object has a
value of active(1).
The f3NtpRemoteClientRowStatus object may be modified if
the associated instance of this object is equal to active(1)."
::= { f3NtpRemoteClientEntry 9 }
--
-- Ethernet Access Port - NTP Flow Point Table
--
f3NtpAccPortFlowPointTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NtpAccPortFlowPointEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of entries corresponding to the Access Port
NTP Flow Point entities."
::= { f3NtpObjects 5 }
f3NtpAccPortFlowPointEntry OBJECT-TYPE
SYNTAX F3NtpAccPortFlowPointEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry containing information applicable to a particular
Access Port NTP Flow Point Entity."
INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
f3NtpAccPortFlowPointIndex }
::= { f3NtpAccPortFlowPointTable 1 }
F3NtpAccPortFlowPointEntry ::=
SEQUENCE {
f3NtpAccPortFlowPointIndex Integer32,
f3NtpAccPortFlowPointAlias DisplayString,
f3NtpAccPortFlowPointAdminState AdminState,
f3NtpAccPortFlowPointOperationalState OperationalState,
f3NtpAccPortFlowPointType NtpFlowPointType,
f3NtpAccPortFlowPointOuterVlanEtherType Integer32,
f3NtpAccPortFlowPointOuterVlanMemberList DisplayString,
f3NtpAccPortFlowPointOuterUntaggedEnabled TruthValue,
f3NtpAccPortFlowPointInner1VlanEtherType Integer32,
f3NtpAccPortFlowPointInner1VlanMemberList DisplayString,
f3NtpAccPortFlowPointInner1UntaggedEnabled TruthValue,
f3NtpAccPortFlowPointInner2VlanEtherType Integer32,
f3NtpAccPortFlowPointInner2VlanMemberList DisplayString,
f3NtpAccPortFlowPointInner2UntaggedEnabled TruthValue,
f3NtpAccPortFlowPointCOS Integer32,
f3NtpAccPortFlowPointCIRLo Unsigned32,
f3NtpAccPortFlowPointCIRHi Unsigned32,
f3NtpAccPortFlowPointEIRLo Unsigned32,
f3NtpAccPortFlowPointEIRHi Unsigned32,
f3NtpAccPortFlowPointBufferSize Unsigned32,
f3NtpAccPortFlowPointStorageType StorageType,
f3NtpAccPortFlowPointRowStatus RowStatus
}
f3NtpAccPortFlowPointIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique index value associated with the Access Port NTP Flow Point."
::= { f3NtpAccPortFlowPointEntry 1 }
f3NtpAccPortFlowPointAlias OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..256))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows SNMP management entities to provide an
alias to the Access Port NTP Flow Point."
::= { f3NtpAccPortFlowPointEntry 2 }
f3NtpAccPortFlowPointAdminState OBJECT-TYPE
SYNTAX AdminState
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object represents the Administrative State of the
NTP Flow Point."
::= { f3NtpAccPortFlowPointEntry 3 }
f3NtpAccPortFlowPointOperationalState OBJECT-TYPE
SYNTAX OperationalState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object represents the Operational State of the NTP Flow
Point."
::= { f3NtpAccPortFlowPointEntry 4 }
f3NtpAccPortFlowPointType OBJECT-TYPE
SYNTAX NtpFlowPointType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object represents the NTP Flow Point Type, i.e. whether
it is for a NTP Server or a NTP Client. Note that only Server Type is
available in this MIB Version."
::= { f3NtpAccPortFlowPointEntry 5 }
f3NtpAccPortFlowPointOuterVlanEtherType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of the Outer VLAN Ether Type
of the NTP Flow."
::= { f3NtpAccPortFlowPointEntry 6 }
f3NtpAccPortFlowPointOuterVlanMemberList OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of the Outer VLAN(s)
of the NTP Flow."
::= { f3NtpAccPortFlowPointEntry 7 }
f3NtpAccPortFlowPointOuterUntaggedEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of whether the Outer VLAN
exists or not."
::= { f3NtpAccPortFlowPointEntry 8 }
f3NtpAccPortFlowPointInner1VlanEtherType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of the Inner1 VLAN Ether Type
of the NTP Flow."
::= { f3NtpAccPortFlowPointEntry 9 }
f3NtpAccPortFlowPointInner1VlanMemberList OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of the Inner1 VLAN(s)
of the NTP Flow."
::= { f3NtpAccPortFlowPointEntry 10 }
f3NtpAccPortFlowPointInner1UntaggedEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of whether the Inner1 VLAN
exists or not."
::= { f3NtpAccPortFlowPointEntry 11 }
f3NtpAccPortFlowPointInner2VlanEtherType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of the Inner2 VLAN Ether Type
of the NTP Flow."
::= { f3NtpAccPortFlowPointEntry 12 }
f3NtpAccPortFlowPointInner2VlanMemberList OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of the Inner2 VLAN(s)
of the NTP Flow."
::= { f3NtpAccPortFlowPointEntry 13 }
f3NtpAccPortFlowPointInner2UntaggedEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of whether the Inner2 VLAN
exists or not."
::= { f3NtpAccPortFlowPointEntry 14 }
f3NtpAccPortFlowPointCOS OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of Class of Service of the traffic
associated with this NTP Flow Point."
::= { f3NtpAccPortFlowPointEntry 15 }
f3NtpAccPortFlowPointCIRLo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of Committed Information Rate of the
traffic associated with this NTP Flow Point.
The CIR value is in bits-per-second units. The value of this object
represents the lower 32 bits of the total CIR value."
::= { f3NtpAccPortFlowPointEntry 16 }
f3NtpAccPortFlowPointCIRHi OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of Committed Information Rate of the
traffic associated with this NTP Flow Point.
The CIR value is in bits-per-second units. The value of this object
represents the higher 32 bits of the total CIR value."
::= { f3NtpAccPortFlowPointEntry 17 }
f3NtpAccPortFlowPointEIRLo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of Excess Information Rate of the
traffic associated with this NTP Flow Point.
The EIR value is in bits-per-second units. The value of this object
represents the lower 32 bits of the total EIR value."
::= { f3NtpAccPortFlowPointEntry 18 }
f3NtpAccPortFlowPointEIRHi OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of Excess Information Rate of the
traffic associated with this NTP Flow Point.
The EIR value is in bits-per-second units. The value of this object
represents the higher 32 bits of the total EIR value."
::= { f3NtpAccPortFlowPointEntry 19 }
f3NtpAccPortFlowPointBufferSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of the Buffer Size of the queue associated
with this NTP Flow Point."
::= { f3NtpAccPortFlowPointEntry 20 }
f3NtpAccPortFlowPointStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of storage configured for this entry."
::= { f3NtpAccPortFlowPointEntry 21 }
f3NtpAccPortFlowPointRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The status of this row. An entry MUST NOT exist in the
active state unless all objects in the entry have an
appropriate value, as described
in the description clause for each writable object.
The values of f3NtpAccPortFlowPointRowStatus supported are
createAndGo(4) and destroy(6). All mandatory attributes
must be specified in a single SNMP SET request with
f3NtpAccPortFlowPointRowStatus value as createAndGo(4).
Upon successful row creation, this object has a
value of active(1).
The f3NtpAccPortFlowPointRowStatus object may be modified if
the associated instance of this object is equal to active(1)."
::= { f3NtpAccPortFlowPointEntry 22 }
--
-- Ethernet Network Port - NTP Flow Point Table
--
f3NtpNetPortFlowPointTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NtpNetPortFlowPointEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of entries corresponding to the Network Port
NTP Flow Point entities."
::= { f3NtpObjects 6 }
f3NtpNetPortFlowPointEntry OBJECT-TYPE
SYNTAX F3NtpNetPortFlowPointEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry containing information applicable to a particular
Network Port NTP Flow Point Entity."
INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
f3NtpNetPortFlowPointIndex }
::= { f3NtpNetPortFlowPointTable 1 }
F3NtpNetPortFlowPointEntry ::=
SEQUENCE {
f3NtpNetPortFlowPointIndex Integer32,
f3NtpNetPortFlowPointAlias DisplayString,
f3NtpNetPortFlowPointAdminState AdminState,
f3NtpNetPortFlowPointOperationalState OperationalState,
f3NtpNetPortFlowPointType NtpFlowPointType,
f3NtpNetPortFlowPointOuterVlanEtherType Integer32,
f3NtpNetPortFlowPointOuterVlanMemberList DisplayString,
f3NtpNetPortFlowPointOuterUntaggedEnabled TruthValue,
f3NtpNetPortFlowPointInner1VlanEtherType Integer32,
f3NtpNetPortFlowPointInner1VlanMemberList DisplayString,
f3NtpNetPortFlowPointInner1UntaggedEnabled TruthValue,
f3NtpNetPortFlowPointInner2VlanEtherType Integer32,
f3NtpNetPortFlowPointInner2VlanMemberList DisplayString,
f3NtpNetPortFlowPointInner2UntaggedEnabled TruthValue,
f3NtpNetPortFlowPointCOS Integer32,
f3NtpNetPortFlowPointCIRLo Unsigned32,
f3NtpNetPortFlowPointCIRHi Unsigned32,
f3NtpNetPortFlowPointEIRLo Unsigned32,
f3NtpNetPortFlowPointEIRHi Unsigned32,
f3NtpNetPortFlowPointBufferSize Unsigned32,
f3NtpNetPortFlowPointStorageType StorageType,
f3NtpNetPortFlowPointRowStatus RowStatus
}
f3NtpNetPortFlowPointIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique index value associated with the Network Port
NTP Flow Point."
::= { f3NtpNetPortFlowPointEntry 1 }
f3NtpNetPortFlowPointAlias OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..256))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows SNMP management entities to provide an
alias to the Network Port NTP Flow Point."
::= { f3NtpNetPortFlowPointEntry 2 }
f3NtpNetPortFlowPointAdminState OBJECT-TYPE
SYNTAX AdminState
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object represents the Administrative State of the
NTP Flow Point."
::= { f3NtpNetPortFlowPointEntry 3 }
f3NtpNetPortFlowPointOperationalState OBJECT-TYPE
SYNTAX OperationalState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object represents the Operational State of the NTP Flow
Point."
::= { f3NtpNetPortFlowPointEntry 4 }
f3NtpNetPortFlowPointType OBJECT-TYPE
SYNTAX NtpFlowPointType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object represents the NTP Flow Point Type, i.e. whether
it is for a NTP Server or a NTP Client. Note that only Server Type is
available in this MIB Version."
::= { f3NtpNetPortFlowPointEntry 5 }
f3NtpNetPortFlowPointOuterVlanEtherType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of the Outer VLAN Ether Type
of the NTP Flow."
::= { f3NtpNetPortFlowPointEntry 6 }
f3NtpNetPortFlowPointOuterVlanMemberList OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of the Outer VLAN(s)
of the NTP Flow."
::= { f3NtpNetPortFlowPointEntry 7 }
f3NtpNetPortFlowPointOuterUntaggedEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of whether the Outer VLAN
exists or not."
::= { f3NtpNetPortFlowPointEntry 8 }
f3NtpNetPortFlowPointInner1VlanEtherType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of the Inner1 VLAN Ether Type
of the NTP Flow."
::= { f3NtpNetPortFlowPointEntry 9 }
f3NtpNetPortFlowPointInner1VlanMemberList OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of the Inner1 VLAN(s)
of the NTP Flow."
::= { f3NtpNetPortFlowPointEntry 10 }
f3NtpNetPortFlowPointInner1UntaggedEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of whether the Inner1 VLAN
exists or not."
::= { f3NtpNetPortFlowPointEntry 11 }
f3NtpNetPortFlowPointInner2VlanEtherType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of the Inner2 VLAN Ether Type
of the NTP Flow."
::= { f3NtpNetPortFlowPointEntry 12 }
f3NtpNetPortFlowPointInner2VlanMemberList OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of the Inner2 VLAN(s)
of the NTP Flow."
::= { f3NtpNetPortFlowPointEntry 13 }
f3NtpNetPortFlowPointInner2UntaggedEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of whether the Inner2 VLAN
exists or not."
::= { f3NtpNetPortFlowPointEntry 14 }
f3NtpNetPortFlowPointCOS OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of Class of Service of the traffic
associated with this NTP Flow Point."
::= { f3NtpNetPortFlowPointEntry 15 }
f3NtpNetPortFlowPointCIRLo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of Committed Information Rate of the
NTP traffic associated with this Flow Point.
The CIR value is in bits-per-second units. The value of this object
represents the lower 32 bits of the total CIR value."
::= { f3NtpNetPortFlowPointEntry 16 }
f3NtpNetPortFlowPointCIRHi OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of Committed Information Rate of the
traffic associated with this NTP Flow Point.
The CIR value is in bits-per-second units. The value of this object
represents the higher 32 bits of the total CIR value."
::= { f3NtpNetPortFlowPointEntry 17 }
f3NtpNetPortFlowPointEIRLo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of Excess Information Rate of the
traffic associated with this NTP Flow Point.
The EIR value is in bits-per-second units. The value of this object
represents the lower 32 bits of the total EIR value."
::= { f3NtpNetPortFlowPointEntry 18 }
f3NtpNetPortFlowPointEIRHi OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of Excess Information Rate of the
traffic associated with this NTP Flow Point.
The EIR value is in bits-per-second units. The value of this object
represents the higher 32 bits of the total EIR value."
::= { f3NtpNetPortFlowPointEntry 19 }
f3NtpNetPortFlowPointBufferSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows specification of the Buffer Size of the queue associated
with this NTP Flow Point."
::= { f3NtpNetPortFlowPointEntry 20 }
f3NtpNetPortFlowPointStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of storage configured for this entry."
::= { f3NtpNetPortFlowPointEntry 21 }
f3NtpNetPortFlowPointRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The status of this row. An entry MUST NOT exist in the
active state unless all objects in the entry have an
appropriate value, as described
in the description clause for each writable object.
The values of f3NtpNetPortFlowPointRowStatus supported are
createAndGo(4) and destroy(6). All mandatory attributes
must be specified in a single SNMP SET request with
f3NtpNetPortFlowPointRowStatus value as createAndGo(4).
Upon successful row creation, this object has a
value of active(1).
The f3NtpNetPortFlowPointRowStatus object may be modified if
the associated instance of this object is equal to active(1)."
::= { f3NtpNetPortFlowPointEntry 22 }
--
-- NTP Tracked Client Table
--
f3NtpTrackedClientTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NtpTrackedClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of entries corresponding to NTP Tracked Client entities."
::= { f3NtpObjects 7 }
f3NtpTrackedClientEntry OBJECT-TYPE
SYNTAX F3NtpTrackedClientEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry containing information applicable to a particular
NTP Tracked Client Entity."
INDEX { neIndex, shelfIndex, slotIndex, f3NtpTrackedClientIndex }
::= { f3NtpTrackedClientTable 1 }
F3NtpTrackedClientEntry ::=
SEQUENCE {
f3NtpTrackedClientIndex Integer32,
f3NtpTrackedClientAlias DisplayString,
f3NtpTrackedClientIpV4Address IpAddress,
f3NtpTrackedClientIpV6Address Ipv6Address,
f3NtpTrackedClientStorageType StorageType,
f3NtpTrackedClientRowStatus RowStatus
}
f3NtpTrackedClientIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique index value associated with the NTP Tracked Client Entity."
::= { f3NtpTrackedClientEntry 1 }
f3NtpTrackedClientAlias OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..256))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows SNMP management entities to provide an
alias to the Tracked Client."
::= { f3NtpTrackedClientEntry 2 }
f3NtpTrackedClientIpV4Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object indicates the IPv4 Address of the NTP Tracked Client."
::= { f3NtpTrackedClientEntry 3 }
f3NtpTrackedClientIpV6Address OBJECT-TYPE
SYNTAX Ipv6Address
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows specification of the unicast IPv6 Address of
the Tracked Client."
::= { f3NtpTrackedClientEntry 4 }
f3NtpTrackedClientStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of storage configured for this entry."
::= { f3NtpTrackedClientEntry 5 }
f3NtpTrackedClientRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The status of this row. An entry MUST NOT exist in the
active state unless all objects in the entry have an
appropriate value, as described
in the description clause for each writable object.
The values of f3NtpTrackedClientRowStatus supported are
createAndGo(4) and destroy(6). All mandatory attributes
must be specified in a single SNMP SET request with
f3NtpRemoteClientRowStatus value as createAndGo(4).
Upon successful row creation, this object has a
value of active(1).
The f3NtpTrackedClientRowStatus object may be modified if
the associated instance of this object is equal to active(1)."
::= { f3NtpTrackedClientEntry 6 }
--
-- NTP Remote Server Table
--
f3NtpRemoteServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NtpRemoteServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of entries corresponding to NTP Server entities."
::= { f3NtpObjects 8 }
f3NtpRemoteServerEntry OBJECT-TYPE
SYNTAX F3NtpRemoteServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry containing information applicable to a particular
NTP Remote Server Entity."
INDEX { neIndex, f3NtpClockIndex, f3NtpRemoteServerIndex }
::= { f3NtpRemoteServerTable 1 }
F3NtpRemoteServerEntry ::=
SEQUENCE {
f3NtpRemoteServerIndex Integer32,
f3NtpRemoteServerAlias DisplayString,
f3NtpRemoteServerAdminState AdminState,
f3NtpRemoteServerOperationalState OperationalState,
f3NtpRemoteServerSecondaryState SecondaryState,
f3NtpRemoteServerServerAddress DisplayString,
f3NtpRemoteServerMinPollInterval NtpPollingInterval,
f3NtpRemoteServerMaxPollInterval NtpPollingInterval,
f3NtpRemoteServerPreferred ToggleValue,
f3NtpRemoteServerReach Unsigned32,
f3NtpRemoteServerStorageType StorageType,
f3NtpRemoteServerRowStatus RowStatus
}
f3NtpRemoteServerIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique index value associated with the NTP Remote Server Entity."
::= { f3NtpRemoteServerEntry 1 }
f3NtpRemoteServerAlias OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..256))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object allows SNMP management entities to provide an
alias to the NTP Remote Server."
::= { f3NtpRemoteServerEntry 2 }
f3NtpRemoteServerAdminState OBJECT-TYPE
SYNTAX AdminState
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object represents the Administrative State of the NTP Remote Server"
::= { f3NtpRemoteServerEntry 3 }
f3NtpRemoteServerOperationalState OBJECT-TYPE
SYNTAX OperationalState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object represents the Operational State of the NTP Remote Server."
::= { f3NtpRemoteServerEntry 4 }
f3NtpRemoteServerSecondaryState OBJECT-TYPE
SYNTAX SecondaryState
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object represents the Secondary State of the NTP Remote Server."
::= { f3NtpRemoteServerEntry 5 }
f3NtpRemoteServerServerAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object specifies the NTP Remote Server Address in form of IPv4 or IPv6 address or hostname."
::= { f3NtpRemoteServerEntry 6 }
f3NtpRemoteServerMinPollInterval OBJECT-TYPE
SYNTAX NtpPollingInterval
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object represents the specifies minimum polling interval on NTP Remote Server."
::= { f3NtpRemoteServerEntry 7 }
f3NtpRemoteServerMaxPollInterval OBJECT-TYPE
SYNTAX NtpPollingInterval
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object represents the specifies maximum polling interval on NTP Remote Server."
::= { f3NtpRemoteServerEntry 8 }
f3NtpRemoteServerPreferred OBJECT-TYPE
SYNTAX ToggleValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object allows server configuration as preferred one on the NTP Remote Server."
::= { f3NtpRemoteServerEntry 9 }
f3NtpRemoteServerReach OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object returns information on packet loss."
::= { f3NtpRemoteServerEntry 10 }
f3NtpRemoteServerStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of storage configured for this entry."
::= { f3NtpRemoteServerEntry 11 }
f3NtpRemoteServerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The status of this row. An entry MUST NOT exist in the
active state unless all objects in the entry have an
appropriate value, as described
in the description clause for each writable object.
The values of f3NtpRemoteServerRowStatus supported are
createAndGo(4) and destroy(6). All mandatory attributes
must be specified in a single SNMP SET request with
f3NtpRemoteServerRowStatus value as createAndGo(4).
Upon successful row creation, this object has a
value of active(1).
The f3NtpRemoteServerRowStatus object may be modified if
the associated instance of this object is equal to active(1)."
::= { f3NtpRemoteServerEntry 12 }
--
-- PERFORMANCE
--
--
-- NTP Clock Interface Statistics Table
--
f3NCIStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NCIStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A collection of NTP Clock Interface(NCI) related statistics.
These reflect the current data."
::= { f3NtpPerformanceObjects 1 }
f3NCIStatsEntry OBJECT-TYPE
SYNTAX F3NCIStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A conceptual row in the f3NCIStatsTable. Entries exist
in this table for each NTP Clock Interface."
INDEX { neIndex, f3NtpClockIndex, f3NCIIndex, f3NCIStatsIndex }
::= { f3NCIStatsTable 1 }
F3NCIStatsEntry ::=
SEQUENCE {
f3NCIStatsIndex Integer32,
f3NCIStatsIntervalType CmPmIntervalType,
f3NCIStatsValid TruthValue,
f3NCIStatsAction CmPmBinAction,
f3NCIStatsRequestsProcessed PerfCounter64,
f3NCIStatsResponsesError PerfCounter64,
f3NCIStatsAuthFailures PerfCounter64,
f3NCIStatsReqsDiscarded PerfCounter64,
f3NCIStatsAvgTPS PerfCounter64,
f3NCIStatsMaxTPS PerfCounter64
}
f3NCIStatsIndex OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An arbitrary integer index value used to uniquely identify
this NTP Clock Interface statistics entry.
1 - 15min
2 - 1day
3 - rollover
4 - 5min"
::= { f3NCIStatsEntry 1 }
f3NCIStatsIntervalType OBJECT-TYPE
SYNTAX CmPmIntervalType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the type of collection, i.e. whether it is
15 Min, 1 Day or rollover."
::= { f3NCIStatsEntry 2 }
f3NCIStatsValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the bin."
::= { f3NCIStatsEntry 3 }
f3NCIStatsAction OBJECT-TYPE
SYNTAX CmPmBinAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Allows the Manager to clear the bin."
::= { f3NCIStatsEntry 4 }
f3NCIStatsRequestsProcessed OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP messages that have been processed by the NCI."
::= { f3NCIStatsEntry 5 }
f3NCIStatsResponsesError OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP Error messages that have been transmitted by
the NCI when messages could not have been processed."
::= { f3NCIStatsEntry 6 }
f3NCIStatsAuthFailures OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP Authentication Failures that have been processed by the NCI."
::= { f3NCIStatsEntry 7 }
f3NCIStatsReqsDiscarded OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP Requests Discarded that have been processed by the NCI."
::= { f3NCIStatsEntry 8 }
f3NCIStatsAvgTPS OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP Average number of PTS."
::= { f3NCIStatsEntry 9 }
f3NCIStatsMaxTPS OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP Maximum number of PTS."
::= { f3NCIStatsEntry 10 }
--
-- NTP Clock Interface History Table
--
f3NCIHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NCIHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A collection history data for each NTP Clock Interface
and different time interval."
::= { f3NtpPerformanceObjects 2 }
f3NCIHistoryEntry OBJECT-TYPE
SYNTAX F3NCIHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A conceptual row in the f3NCIHistoryTable.
Entries exist in this table for each NTP Clock Interface
and different time interval."
INDEX { neIndex, f3NtpClockIndex, f3NCIIndex, f3NCIStatsIndex,
f3NCIHistoryIndex }
::= { f3NCIHistoryTable 1 }
F3NCIHistoryEntry ::=
SEQUENCE {
f3NCIHistoryIndex Integer32,
f3NCIHistoryTime DateAndTime,
f3NCIHistoryValid TruthValue,
f3NCIHistoryAction CmPmBinAction,
f3NCIHistoryRequestsProcessed PerfCounter64,
f3NCIHistoryResponsesError PerfCounter64,
f3NCIHistoryAuthFailures PerfCounter64,
f3NCIHistoryReqsDiscarded PerfCounter64,
f3NCIHistoryAvgTPS PerfCounter64,
f3NCIHistoryMaxTPS PerfCounter64
}
f3NCIHistoryIndex OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An arbitrary integer index value used to uniquely identify
this NTP Clock Interface and time interval entry."
::= { f3NCIHistoryEntry 1 }
f3NCIHistoryTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the time of history bin creation."
::= { f3NCIHistoryEntry 2 }
f3NCIHistoryValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the bin."
::= { f3NCIHistoryEntry 3 }
f3NCIHistoryAction OBJECT-TYPE
SYNTAX CmPmBinAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Allows the Manager to clear the bin."
::= { f3NCIHistoryEntry 4 }
f3NCIHistoryRequestsProcessed OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP messages that have been processed by the NCI."
::= { f3NCIHistoryEntry 5 }
f3NCIHistoryResponsesError OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP Error messages that have been transmitted by
the NCI when messages could not have been processed."
::= { f3NCIHistoryEntry 6 }
f3NCIHistoryAuthFailures OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP Authentication Failures that have been processed by the NCI."
::= { f3NCIHistoryEntry 7 }
f3NCIHistoryReqsDiscarded OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP Requests Discarded that have been processed by the NCI."
::= { f3NCIHistoryEntry 8 }
f3NCIHistoryAvgTPS OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP Average number of PTS."
::= { f3NCIHistoryEntry 9 }
f3NCIHistoryMaxTPS OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP Maximum number of PTS."
::= { f3NCIHistoryEntry 10 }
--
-- NTP Clock Interface Threshold Table
--
f3NCIThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NCIThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of entries that allow manageability of
a list of Thresholds for NTP Clock Interface."
::= { f3NtpPerformanceObjects 3 }
f3NCIThresholdEntry OBJECT-TYPE
SYNTAX F3NCIThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A conceptual row in the f3NCIThresholdTable."
INDEX { neIndex, f3NtpClockIndex, f3NCIIndex, f3NCIStatsIndex,
f3NCIThresholdIndex }
::= { f3NCIThresholdTable 1 }
F3NCIThresholdEntry ::=
SEQUENCE {
f3NCIThresholdIndex Integer32,
f3NCIThresholdInterval CmPmIntervalType,
f3NCIThresholdVariable VariablePointer,
f3NCIThresholdValueLo Unsigned32,
f3NCIThresholdValueHi Unsigned32,
f3NCIThresholdMonValue PerfCounter64
}
f3NCIThresholdIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An index that uniquely identifies an entry in the
f3NCIThresholdTable."
::= { f3NCIThresholdEntry 1 }
f3NCIThresholdInterval OBJECT-TYPE
SYNTAX CmPmIntervalType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The time interval over which monitored value is
sampled and compared with the specified threshold."
::= { f3NCIThresholdEntry 2 }
f3NCIThresholdVariable OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The object identifier of the particular variable to be sampled."
::= { f3NCIThresholdEntry 3 }
f3NCIThresholdValueLo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Lower 32 bits of the threshold value."
::= { f3NCIThresholdEntry 4 }
f3NCIThresholdValueHi OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Higher 32 bits of the threshold value."
::= { f3NCIThresholdEntry 5 }
f3NCIThresholdMonValue OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Monitored value corresponding to f3NCIThresholdVariable value."
::= { f3NCIThresholdEntry 6 }
--
-- Access Port NTP Flow Point Statistics Table
--
f3NtpAccPortFlowPointStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NtpAccPortFlowPointStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A collection of Access Port NTP Flow Point statistics.
These reflect the current data."
::= { f3NtpPerformanceObjects 4 }
f3NtpAccPortFlowPointStatsEntry OBJECT-TYPE
SYNTAX F3NtpAccPortFlowPointStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A conceptual row in the f3NtpAccPortFlowPointStatsTable.
Entries exist in this table for each Access Port NTP Flow Point."
INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
f3NtpAccPortFlowPointIndex, f3NtpAccPortFlowPointStatsIndex }
::= { f3NtpAccPortFlowPointStatsTable 1 }
F3NtpAccPortFlowPointStatsEntry ::=
SEQUENCE {
f3NtpAccPortFlowPointStatsIndex Integer32,
f3NtpAccPortFlowPointStatsIntervalType CmPmIntervalType,
f3NtpAccPortFlowPointStatsValid TruthValue,
f3NtpAccPortFlowPointStatsAction CmPmBinAction,
f3NtpAccPortFlowPointStatsRequestsDropped PerfCounter64,
f3NtpAccPortFlowPointStatsRequestsReceived PerfCounter64,
f3NtpAccPortFlowPointStatsResponsesTransmitted PerfCounter64
}
f3NtpAccPortFlowPointStatsIndex OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An arbitrary integer index value used to uniquely identify
this Access Port NTP Flow Point statistics entry.
1 - 15min
2 - 1day
3 - rollover
4 - 5min"
::= { f3NtpAccPortFlowPointStatsEntry 1 }
f3NtpAccPortFlowPointStatsIntervalType OBJECT-TYPE
SYNTAX CmPmIntervalType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the type of collection, i.e. whether it is
5 Min, 15 Min, 1 Day or rollover."
::= { f3NtpAccPortFlowPointStatsEntry 2 }
f3NtpAccPortFlowPointStatsValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the bin."
::= { f3NtpAccPortFlowPointStatsEntry 3 }
f3NtpAccPortFlowPointStatsAction OBJECT-TYPE
SYNTAX CmPmBinAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Allows the Manager to clear the bin."
::= { f3NtpAccPortFlowPointStatsEntry 4 }
f3NtpAccPortFlowPointStatsRequestsDropped OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP messages that have been dropped from the NTP Flow Point."
::= { f3NtpAccPortFlowPointStatsEntry 5 }
f3NtpAccPortFlowPointStatsRequestsReceived OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP messages that have been recieved on the NTP Flow Point."
::= { f3NtpAccPortFlowPointStatsEntry 6 }
f3NtpAccPortFlowPointStatsResponsesTransmitted OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP messages that have been transmitted on the NTP Flow Point."
::= { f3NtpAccPortFlowPointStatsEntry 7 }
--
-- Access Port NTP Flow Point History Table
--
f3NtpAccPortFlowPointHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NtpAccPortFlowPointHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A collection of Access Port NTP Flow Point history statistics.
These reflect the history data."
::= { f3NtpPerformanceObjects 5 }
f3NtpAccPortFlowPointHistoryEntry OBJECT-TYPE
SYNTAX F3NtpAccPortFlowPointHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A conceptual row in the f3NtpAccPortFlowPointHistoryTable.
Entries exist in this table for each Access Port Flow Point."
INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
f3NtpAccPortFlowPointIndex, f3NtpAccPortFlowPointStatsIndex,
f3NtpAccPortFlowPointHistoryIndex }
::= { f3NtpAccPortFlowPointHistoryTable 1 }
F3NtpAccPortFlowPointHistoryEntry ::=
SEQUENCE {
f3NtpAccPortFlowPointHistoryIndex Integer32,
f3NtpAccPortFlowPointHistoryTime DateAndTime,
f3NtpAccPortFlowPointHistoryValid TruthValue,
f3NtpAccPortFlowPointHistoryAction CmPmBinAction,
f3NtpAccPortFlowPointHistoryRequestsDropped PerfCounter64,
f3NtpAccPortFlowPointHistoryRequestsReceived PerfCounter64,
f3NtpAccPortFlowPointHistoryResponsesTransmitted PerfCounter64
}
f3NtpAccPortFlowPointHistoryIndex OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An arbitrary integer index value used to uniquely identify
this Ethernet Access Port NTP Flow point history bin entry."
::= { f3NtpAccPortFlowPointHistoryEntry 1 }
f3NtpAccPortFlowPointHistoryTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the time of history bin creation."
::= { f3NtpAccPortFlowPointHistoryEntry 2 }
f3NtpAccPortFlowPointHistoryValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the bin."
::= { f3NtpAccPortFlowPointHistoryEntry 3 }
f3NtpAccPortFlowPointHistoryAction OBJECT-TYPE
SYNTAX CmPmBinAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Allows the Manager to clear the bin."
::= { f3NtpAccPortFlowPointHistoryEntry 4 }
f3NtpAccPortFlowPointHistoryRequestsDropped OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP messages that have been dropped from the NTP Flow Point."
::= { f3NtpAccPortFlowPointHistoryEntry 5 }
f3NtpAccPortFlowPointHistoryRequestsReceived OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP messages that have been recieved on the NTP Flow Point."
::= { f3NtpAccPortFlowPointHistoryEntry 6 }
f3NtpAccPortFlowPointHistoryResponsesTransmitted OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP messages that have been transmitted on the NTP Flow Point."
::= { f3NtpAccPortFlowPointHistoryEntry 7 }
--
-- Access Port NTP Flow Point Threshold Table
--
f3NtpAccPortFlowPointThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NtpAccPortFlowPointThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of entries that allow manageability of Access Port NTP Flow Point
Thresholds."
::= { f3NtpPerformanceObjects 6 }
f3NtpAccPortFlowPointThresholdEntry OBJECT-TYPE
SYNTAX F3NtpAccPortFlowPointThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A conceptual row in the f3NtpAccPortFlowPointThresholdTable."
INDEX { neIndex, shelfIndex, slotIndex, cmEthernetAccPortIndex,
f3NtpAccPortFlowPointIndex, f3NtpAccPortFlowPointStatsIndex,
f3NtpAccPortFlowPointThresholdIndex }
::= { f3NtpAccPortFlowPointThresholdTable 1 }
F3NtpAccPortFlowPointThresholdEntry ::=
SEQUENCE {
f3NtpAccPortFlowPointThresholdIndex Integer32,
f3NtpAccPortFlowPointThresholdInterval CmPmIntervalType,
f3NtpAccPortFlowPointThresholdVariable VariablePointer,
f3NtpAccPortFlowPointThresholdValueLo Unsigned32,
f3NtpAccPortFlowPointThresholdValueHi Unsigned32,
f3NtpAccPortFlowPointThresholdMonValue PerfCounter64
}
f3NtpAccPortFlowPointThresholdIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An index that uniquely identifies an entry in the
f3NtpAccPortFlowPointThresholdTable."
::= { f3NtpAccPortFlowPointThresholdEntry 1 }
f3NtpAccPortFlowPointThresholdInterval OBJECT-TYPE
SYNTAX CmPmIntervalType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The interval over which monitored value is
sampled and compared with the specified threshold."
::= { f3NtpAccPortFlowPointThresholdEntry 2 }
f3NtpAccPortFlowPointThresholdVariable OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The object identifier of the particular variable to be
sampled."
::= { f3NtpAccPortFlowPointThresholdEntry 3 }
f3NtpAccPortFlowPointThresholdValueLo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Lower 32 bits of the threshold value."
::= { f3NtpAccPortFlowPointThresholdEntry 4 }
f3NtpAccPortFlowPointThresholdValueHi OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Higher 32 bits of the threshold value."
::= { f3NtpAccPortFlowPointThresholdEntry 5 }
f3NtpAccPortFlowPointThresholdMonValue OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Monitored value corresponding to f3NtpAccPortFlowPointThresholdVariable."
::= { f3NtpAccPortFlowPointThresholdEntry 6 }
--
-- Network Port NTP Flow Point Statistics Table
--
f3NtpNetPortFlowPointStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NtpNetPortFlowPointStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A collection of Network Port NTP Flow Point statistics.
These reflect the current data."
::= { f3NtpPerformanceObjects 7 }
f3NtpNetPortFlowPointStatsEntry OBJECT-TYPE
SYNTAX F3NtpNetPortFlowPointStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A conceptual row in the f3NtpNetPortFlowPointStatsTable.
Entries exist in this table for each Network Port NTP Flow Point."
INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
f3NtpNetPortFlowPointIndex, f3NtpNetPortFlowPointStatsIndex }
::= { f3NtpNetPortFlowPointStatsTable 1 }
F3NtpNetPortFlowPointStatsEntry ::=
SEQUENCE {
f3NtpNetPortFlowPointStatsIndex Integer32,
f3NtpNetPortFlowPointStatsIntervalType CmPmIntervalType,
f3NtpNetPortFlowPointStatsValid TruthValue,
f3NtpNetPortFlowPointStatsAction CmPmBinAction,
f3NtpNetPortFlowPointStatsRequestsDropped PerfCounter64,
f3NtpNetPortFlowPointStatsRequestsReceived PerfCounter64,
f3NtpNetPortFlowPointStatsResponsesTransmitted PerfCounter64
}
f3NtpNetPortFlowPointStatsIndex OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An arbitrary integer index value used to uniquely identify
this Network Port NTP Flow Point statistics entry.
1 - 15min
2 - 1day
3 - rollover
4 - 5min"
::= { f3NtpNetPortFlowPointStatsEntry 1 }
f3NtpNetPortFlowPointStatsIntervalType OBJECT-TYPE
SYNTAX CmPmIntervalType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the type of collection, i.e. whether it is
5 Min, 15 Min, 1 Day or rollover."
::= { f3NtpNetPortFlowPointStatsEntry 2 }
f3NtpNetPortFlowPointStatsValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the bin."
::= { f3NtpNetPortFlowPointStatsEntry 3 }
f3NtpNetPortFlowPointStatsAction OBJECT-TYPE
SYNTAX CmPmBinAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Allows the Manager to clear the bin."
::= { f3NtpNetPortFlowPointStatsEntry 4 }
f3NtpNetPortFlowPointStatsRequestsDropped OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP messages that have been dropped from the NTP Flow Point."
::= { f3NtpNetPortFlowPointStatsEntry 5 }
f3NtpNetPortFlowPointStatsRequestsReceived OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP messages that have been recieved on the NTP Flow Point."
::= { f3NtpNetPortFlowPointStatsEntry 6 }
f3NtpNetPortFlowPointStatsResponsesTransmitted OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP messages that have been transmitted on the NTP Flow Point."
::= { f3NtpNetPortFlowPointStatsEntry 7 }
--
-- Network Port NTP Flow Point History Table
--
f3NtpNetPortFlowPointHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NtpNetPortFlowPointHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A collection of Network Port NTP Flow Point history statistics.
These reflect the history data."
::= { f3NtpPerformanceObjects 8 }
f3NtpNetPortFlowPointHistoryEntry OBJECT-TYPE
SYNTAX F3NtpNetPortFlowPointHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A conceptual row in the f3NtpNetPortFlowPointHistoryTable.
Entries exist in this table for each Network Port NTP Flow Point."
INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
f3NtpNetPortFlowPointIndex, f3NtpNetPortFlowPointStatsIndex,
f3NtpNetPortFlowPointHistoryIndex }
::= { f3NtpNetPortFlowPointHistoryTable 1 }
F3NtpNetPortFlowPointHistoryEntry ::=
SEQUENCE {
f3NtpNetPortFlowPointHistoryIndex Integer32,
f3NtpNetPortFlowPointHistoryTime DateAndTime,
f3NtpNetPortFlowPointHistoryValid TruthValue,
f3NtpNetPortFlowPointHistoryAction CmPmBinAction,
f3NtpNetPortFlowPointHistoryRequestsDropped PerfCounter64,
f3NtpNetPortFlowPointHistoryRequestsReceived PerfCounter64,
f3NtpNetPortFlowPointHistoryResponsesTransmitted PerfCounter64
}
f3NtpNetPortFlowPointHistoryIndex OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An arbitrary integer index value used to uniquely identify
this Ethernet Traffic Port NTP Flow point history bin entry."
::= { f3NtpNetPortFlowPointHistoryEntry 1 }
f3NtpNetPortFlowPointHistoryTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the time of history bin creation."
::= { f3NtpNetPortFlowPointHistoryEntry 2 }
f3NtpNetPortFlowPointHistoryValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the bin."
::= { f3NtpNetPortFlowPointHistoryEntry 3 }
f3NtpNetPortFlowPointHistoryAction OBJECT-TYPE
SYNTAX CmPmBinAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Allows the Manager to clear the bin."
::= { f3NtpNetPortFlowPointHistoryEntry 4 }
f3NtpNetPortFlowPointHistoryRequestsDropped OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP messages that have been dropped from the NTP Flow Point."
::= { f3NtpNetPortFlowPointHistoryEntry 5 }
f3NtpNetPortFlowPointHistoryRequestsReceived OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP messages that have been recieved on the NTP Flow Point."
::= { f3NtpNetPortFlowPointHistoryEntry 6 }
f3NtpNetPortFlowPointHistoryResponsesTransmitted OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of NTP messages that have been transmitted on the NTP Flow Point."
::= { f3NtpNetPortFlowPointHistoryEntry 7 }
--
-- Network Port NTP Flow Point Threshold Table
--
f3NtpNetPortFlowPointThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NtpNetPortFlowPointThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of entries that allow manageability of Network Port NTP Flow Point
Thresholds."
::= { f3NtpPerformanceObjects 9 }
f3NtpNetPortFlowPointThresholdEntry OBJECT-TYPE
SYNTAX F3NtpNetPortFlowPointThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A conceptual row in the f3NtpNetPortFlowPointThresholdTable."
INDEX { neIndex, shelfIndex, slotIndex, cmEthernetNetPortIndex,
f3NtpNetPortFlowPointIndex, f3NtpNetPortFlowPointStatsIndex,
f3NtpNetPortFlowPointThresholdIndex }
::= { f3NtpNetPortFlowPointThresholdTable 1 }
F3NtpNetPortFlowPointThresholdEntry ::=
SEQUENCE {
f3NtpNetPortFlowPointThresholdIndex Integer32,
f3NtpNetPortFlowPointThresholdInterval CmPmIntervalType,
f3NtpNetPortFlowPointThresholdVariable VariablePointer,
f3NtpNetPortFlowPointThresholdValueLo Unsigned32,
f3NtpNetPortFlowPointThresholdValueHi Unsigned32,
f3NtpNetPortFlowPointThresholdMonValue PerfCounter64
}
f3NtpNetPortFlowPointThresholdIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An index that uniquely identifies an entry in the
f3NtpNetPortFlowPointThresholdTable."
::= { f3NtpNetPortFlowPointThresholdEntry 1 }
f3NtpNetPortFlowPointThresholdInterval OBJECT-TYPE
SYNTAX CmPmIntervalType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The interval over which monitored value is
sampled and compared with the specified threshold."
::= { f3NtpNetPortFlowPointThresholdEntry 2 }
f3NtpNetPortFlowPointThresholdVariable OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The object identifier of the particular variable to be
sampled."
::= { f3NtpNetPortFlowPointThresholdEntry 3 }
f3NtpNetPortFlowPointThresholdValueLo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Lower 32 bits of the threshold value."
::= { f3NtpNetPortFlowPointThresholdEntry 4 }
f3NtpNetPortFlowPointThresholdValueHi OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Higher 32 bits of the threshold value."
::= { f3NtpNetPortFlowPointThresholdEntry 5 }
f3NtpNetPortFlowPointThresholdMonValue OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Monitored value corresponding to f3NtpNetPortFlowPointThresholdVariable."
::= { f3NtpNetPortFlowPointThresholdEntry 6 }
--
-- PERFORMANCE
--
--
-- NTP Tracked Client Statistics Table
--
f3NtpTrackedClientStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NtpTrackedClientStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A collection of NTP Tracked Client related statistics.
These reflect the current data."
::= { f3NtpPerformanceObjects 10 }
f3NtpTrackedClientStatsEntry OBJECT-TYPE
SYNTAX F3NtpTrackedClientStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A conceptual row in the f3NtpTrackedClientStatsTable. Entries exist
in this table for each NTP Tracked Client."
INDEX { neIndex, f3NtpClockIndex, f3NCIIndex, f3NtpTrackedClientStatsClientIndex,
f3NtpTrackedClientStatsIndex }
::= { f3NtpTrackedClientStatsTable 1 }
F3NtpTrackedClientStatsEntry ::=
SEQUENCE {
f3NtpTrackedClientStatsIndex Integer32,
f3NtpTrackedClientStatsClientIndex Integer32,
f3NtpTrackedClientStatsIntervalType CmPmIntervalType,
f3NtpTrackedClientStatsValid TruthValue,
f3NtpTrackedClientStatsAction CmPmBinAction,
f3NtpTrackedClientStatsResponsesTransmitted PerfCounter64,
f3NtpTrackedClientStatsRequestsReceived PerfCounter64
}
f3NtpTrackedClientStatsIndex OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An arbitrary integer index value used to uniquely identify
this NTP Tracked Client statistics entry.
1 - 15min
2 - 1day
3 - rollover
4 - 5min"
::= { f3NtpTrackedClientStatsEntry 1 }
f3NtpTrackedClientStatsClientIndex OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An arbitrary integer index value used to uniquely identify
this NTP Tracked Client ."
::= { f3NtpTrackedClientStatsEntry 2 }
f3NtpTrackedClientStatsIntervalType OBJECT-TYPE
SYNTAX CmPmIntervalType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the type of collection, i.e. whether it is
15 Min, 1 Day or rollover."
::= { f3NtpTrackedClientStatsEntry 3 }
f3NtpTrackedClientStatsValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the bin."
::= { f3NtpTrackedClientStatsEntry 4 }
f3NtpTrackedClientStatsAction OBJECT-TYPE
SYNTAX CmPmBinAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Allows the Manager to clear the bin."
::= { f3NtpTrackedClientStatsEntry 5 }
f3NtpTrackedClientStatsResponsesTransmitted OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of messages that have been transmitted by the Ntp Tracked Client."
::= { f3NtpTrackedClientStatsEntry 6 }
f3NtpTrackedClientStatsRequestsReceived OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of requests messages that have been received by the NtpTrackedClient."
::= { f3NtpTrackedClientStatsEntry 7 }
--
-- NTP Tracked Client History Table
--
f3NtpTrackedClientHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NtpTrackedClientHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A collection history data for each NTP Tracked Client
and different time interval."
::= { f3NtpPerformanceObjects 11 }
f3NtpTrackedClientHistoryEntry OBJECT-TYPE
SYNTAX F3NtpTrackedClientHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A conceptual row in the f3NtpTrackedClientHistoryTable.
Entries exist in this table for each NTP Tracked Client
and different time interval."
INDEX { neIndex, f3NtpClockIndex, f3NCIIndex, f3NtpTrackedClientStatsClientIndex,
f3NtpTrackedClientStatsIndex, f3NtpTrackedClientHistoryIndex }
::= { f3NtpTrackedClientHistoryTable 1 }
F3NtpTrackedClientHistoryEntry ::=
SEQUENCE {
f3NtpTrackedClientHistoryIndex Integer32,
f3NtpTrackedClientHistoryTime DateAndTime,
f3NtpTrackedClientHistoryValid TruthValue,
f3NtpTrackedClientHistoryAction CmPmBinAction,
f3NtpTrackedClientHistoryResponsesTransmitted PerfCounter64,
f3NtpTrackedClientHistoryRequestsReceived PerfCounter64
}
f3NtpTrackedClientHistoryIndex OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An arbitrary integer index value used to uniquely identify
this NTP Tracked Client and time interval entry."
::= { f3NtpTrackedClientHistoryEntry 1 }
f3NtpTrackedClientHistoryTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the time of history bin creation."
::= { f3NtpTrackedClientHistoryEntry 2 }
f3NtpTrackedClientHistoryValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the validity of the bin."
::= { f3NtpTrackedClientHistoryEntry 3 }
f3NtpTrackedClientHistoryAction OBJECT-TYPE
SYNTAX CmPmBinAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Allows the Manager to clear the bin."
::= { f3NtpTrackedClientHistoryEntry 4 }
f3NtpTrackedClientHistoryResponsesTransmitted OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of responses that have been transmitted."
::= { f3NtpTrackedClientHistoryEntry 5 }
f3NtpTrackedClientHistoryRequestsReceived OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Count of requests that have been received."
::= { f3NtpTrackedClientHistoryEntry 6 }
--
-- NTP Tracked Client Threshold Table
--
f3NtpTrackedClientThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF F3NtpTrackedClientThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of entries that allow manageability of
a list of Thresholds for NTP Tracked Client."
::= { f3NtpPerformanceObjects 12 }
f3NtpTrackedClientThresholdEntry OBJECT-TYPE
SYNTAX F3NtpTrackedClientThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A conceptual row in the f3NtpTrackedClientThresholdTable."
INDEX { neIndex, f3NtpClockIndex, f3NCIIndex, f3NtpTrackedClientStatsClientIndex,
f3NtpTrackedClientStatsIndex, f3NtpTrackedClientThresholdIndex }
::= { f3NtpTrackedClientThresholdTable 1 }
F3NtpTrackedClientThresholdEntry ::=
SEQUENCE {
f3NtpTrackedClientThresholdIndex Integer32,
f3NtpTrackedClientThresholdInterval CmPmIntervalType,
f3NtpTrackedClientThresholdVariable VariablePointer,
f3NtpTrackedClientThresholdValueLo Unsigned32,
f3NtpTrackedClientThresholdValueHi Unsigned32,
f3NtpTrackedClientThresholdMonValue PerfCounter64
}
f3NtpTrackedClientThresholdIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An index that uniquely identifies an entry in the
f3NtpTrackedClientThresholdTable."
::= { f3NtpTrackedClientThresholdEntry 1 }
f3NtpTrackedClientThresholdInterval OBJECT-TYPE
SYNTAX CmPmIntervalType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The time interval over which monitored value is
sampled and compared with the specified threshold."
::= { f3NtpTrackedClientThresholdEntry 2 }
f3NtpTrackedClientThresholdVariable OBJECT-TYPE
SYNTAX VariablePointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The object identifier of the particular variable to be sampled."
::= { f3NtpTrackedClientThresholdEntry 3 }
f3NtpTrackedClientThresholdValueLo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Lower 32 bits of the threshold value."
::= { f3NtpTrackedClientThresholdEntry 4 }
f3NtpTrackedClientThresholdValueHi OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Higher 32 bits of the threshold value."
::= { f3NtpTrackedClientThresholdEntry 5 }
f3NtpTrackedClientThresholdMonValue OBJECT-TYPE
SYNTAX PerfCounter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Monitored value corresponding to f3NtpTrackedClientThresholdVariable value."
::= { f3NtpTrackedClientThresholdEntry 6 }
f3NtpTrackedClientCrossingAlert NOTIFICATION-TYPE
OBJECTS {
f3NtpTrackedClientThresholdIndex,
f3NtpTrackedClientThresholdInterval,
f3NtpTrackedClientThresholdVariable,
f3NtpTrackedClientThresholdValueLo,
f3NtpTrackedClientThresholdValueHi,
f3NtpTrackedClientThresholdMonValue
}
STATUS current
DESCRIPTION
"This trap is sent each time a threshold on a PM condition
on an NtpTrackedClient is crossed."
::= { f3NtpPerformanceNotifications 1 }
--
-- Conformance
--
f3NtpCompliances OBJECT IDENTIFIER ::= {f3NtpConformance 1}
f3NtpGroups OBJECT IDENTIFIER ::= {f3NtpConformance 2}
f3NtpCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "Describes the requirements for conformance to the F3 NTP
group."
MODULE -- this module
MANDATORY-GROUPS {
f3NtpObjectGroup, f3NtpPerfObjectGroup
}
::= { f3NtpCompliances 1 }
f3NtpObjectGroup OBJECT-GROUP
OBJECTS {
f3NtpClockIndex, f3NtpClockAlias,
f3NtpClockAdminState, f3NtpClockOperationalState,
f3NtpClockTimeClock, f3NtpClockStratumLevel,
f3NtpClockLeapIndicator, f3NtpClockTimeScale,
f3NtpClockPrecision, f3NtpClockRootDelay,
f3NtpClockRootDispersion, f3NtpClockNtpMode,
f3NtpClockNtpType, f3NtpClockNtpAuthentication,
f3NtpClockServerState, f3NtpClockTimeReferenceLossHandling,
f3NtpClockRefClockId, f3NtpClockStorageType, f3NtpClockRowStatus,
f3NtpAuthenticationSecureMode,f3NtpAutokeyCtrl, f3NtpClockOffset, f3NtpClockSecondaryState,
f3NCIIndex, f3NCIAlias,
f3NCIAdminState, f3NCIOperationalState,
f3NCIIfName, f3NCIIpProtocol,
f3NCIIpV4Address, f3NCIIpV4SubnetMask,
f3NCIDscp, f3NCIStorageType, f3NCIRowStatus,
f3NCIIpV6UdpChecksum, f3NCIIpV6Address,
f3NCIIpV6AddrPrefixLength, f3NCIIpV4Gateway,
f3NCIIpV6Gateway,f3NCIDefaultGatewayControl,
f3NCIDaytimeServiceControl, f3NCITimeServiceControl,
f3NCIBroadcastState, f3NCIBroadcastIpV4Address,
f3NCIBroadcastIpV6Address, f3NCIBroadcastInterval,
f3NCIBroadcastMaxHops, f3NCIBroadcastSymKeyId,
f3NCIBroadcastNtpVersion,
f3NCIAssociationMode, f3NCIPeer1IpV4Address,
f3NCIPeer2IpV4Address, f3NCIPeer3IpV4Address,
f3NCIPeer1IpV6Address, f3NCIPeer2IpV6Address,
f3NCIPeer3IpV6Address, f3NCIPeerMinInterval,
f3NCIPeerMaxInterval, f3NCIPeerSymKeyIdList,
f3NCITimeScale, f3NCICurrentTimeOfDay,
f3NCINtpHardenedResponderControl,
f3NtpVirtualPortIndex, f3NtpVirtualPortAlias,
f3NtpVirtualPortAdminState, f3NtpVirtualPortOperationalState,
f3NtpVirtualPortNtpFlowPoint,
f3NtpVirtualPortStorageType, f3NtpVirtualPortRowStatus,
f3NtpRemoteClientIndex, f3NtpRemoteClientIpV4Address,
f3NtpRemoteClientRxPackets, f3NtpRemoteClientAvgPollInterval,
f3NtpRemoteClientLastPollInterval, f3NtpRemoteClientNtpMode,
f3NtpRemoteClientNtpVersion, f3NtpRemoteClientStorageType,
f3NtpRemoteClientRowStatus,
f3NtpAccPortFlowPointIndex, f3NtpAccPortFlowPointAlias,
f3NtpAccPortFlowPointAdminState, f3NtpAccPortFlowPointOperationalState,
f3NtpAccPortFlowPointType,
f3NtpAccPortFlowPointOuterVlanEtherType, f3NtpAccPortFlowPointOuterVlanMemberList,
f3NtpAccPortFlowPointOuterUntaggedEnabled, f3NtpAccPortFlowPointInner1VlanEtherType,
f3NtpAccPortFlowPointInner1VlanMemberList, f3NtpAccPortFlowPointInner1UntaggedEnabled,
f3NtpAccPortFlowPointInner2VlanEtherType, f3NtpAccPortFlowPointInner2VlanMemberList,
f3NtpAccPortFlowPointInner2UntaggedEnabled, f3NtpAccPortFlowPointCOS,
f3NtpAccPortFlowPointCIRLo, f3NtpAccPortFlowPointCIRHi,
f3NtpAccPortFlowPointEIRLo, f3NtpAccPortFlowPointEIRHi,
f3NtpAccPortFlowPointBufferSize, f3NtpAccPortFlowPointStorageType, f3NtpAccPortFlowPointRowStatus,
f3NtpNetPortFlowPointIndex, f3NtpNetPortFlowPointAlias,
f3NtpNetPortFlowPointAdminState, f3NtpNetPortFlowPointOperationalState,
f3NtpNetPortFlowPointType,
f3NtpNetPortFlowPointOuterVlanEtherType, f3NtpNetPortFlowPointOuterVlanMemberList,
f3NtpNetPortFlowPointOuterUntaggedEnabled, f3NtpNetPortFlowPointInner1VlanEtherType,
f3NtpNetPortFlowPointInner1VlanMemberList, f3NtpNetPortFlowPointInner1UntaggedEnabled,
f3NtpNetPortFlowPointInner2VlanEtherType, f3NtpNetPortFlowPointInner2VlanMemberList,
f3NtpNetPortFlowPointInner2UntaggedEnabled, f3NtpNetPortFlowPointCOS,
f3NtpNetPortFlowPointCIRLo, f3NtpNetPortFlowPointCIRHi,
f3NtpNetPortFlowPointEIRLo, f3NtpNetPortFlowPointEIRHi,
f3NtpNetPortFlowPointBufferSize, f3NtpNetPortFlowPointStorageType, f3NtpNetPortFlowPointRowStatus,
f3NtpTrackedClientIndex, f3NtpTrackedClientAlias,
f3NtpTrackedClientIpV4Address, f3NtpTrackedClientIpV6Address,
f3NtpTrackedClientStorageType, f3NtpTrackedClientRowStatus,
f3NtpRemoteServerIndex, f3NtpRemoteServerAlias, f3NtpRemoteServerAdminState,
f3NtpRemoteServerOperationalState, f3NtpRemoteServerServerAddress,
f3NtpRemoteServerMinPollInterval, f3NtpRemoteServerMaxPollInterval,
f3NtpRemoteServerPreferred, f3NtpRemoteServerReach,
f3NtpRemoteServerStorageType, f3NtpRemoteServerRowStatus
}
STATUS current
DESCRIPTION "A collection of objects used to manage the F3 NTP Object group."
::= { f3NtpGroups 1 }
f3NtpPerfObjectGroup OBJECT-GROUP
OBJECTS {
f3NCIStatsIndex, f3NCIStatsIntervalType,
f3NCIStatsValid, f3NCIStatsAction,
f3NCIStatsRequestsProcessed, f3NCIStatsResponsesError,
f3NCIStatsAuthFailures,
f3NCIStatsReqsDiscarded,
f3NCIStatsAvgTPS,
f3NCIStatsMaxTPS,
f3NCIHistoryIndex, f3NCIHistoryTime,
f3NCIHistoryValid, f3NCIHistoryAction,
f3NCIHistoryRequestsProcessed, f3NCIHistoryResponsesError,
f3NCIHistoryAuthFailures,
f3NCIHistoryReqsDiscarded,
f3NCIHistoryAvgTPS,
f3NCIHistoryMaxTPS,
f3NCIThresholdIndex, f3NCIThresholdInterval,
f3NCIThresholdVariable, f3NCIThresholdValueLo,
f3NCIThresholdValueHi, f3NCIThresholdMonValue,
f3NtpAccPortFlowPointStatsIndex, f3NtpAccPortFlowPointStatsIntervalType,
f3NtpAccPortFlowPointStatsValid, f3NtpAccPortFlowPointStatsAction,
f3NtpAccPortFlowPointStatsRequestsDropped,
f3NtpAccPortFlowPointStatsRequestsReceived, f3NtpAccPortFlowPointStatsResponsesTransmitted,
f3NtpAccPortFlowPointHistoryIndex, f3NtpAccPortFlowPointHistoryTime,
f3NtpAccPortFlowPointHistoryValid, f3NtpAccPortFlowPointHistoryAction,
f3NtpAccPortFlowPointHistoryRequestsDropped,
f3NtpAccPortFlowPointHistoryRequestsReceived, f3NtpAccPortFlowPointHistoryResponsesTransmitted,
f3NtpAccPortFlowPointThresholdIndex, f3NtpAccPortFlowPointThresholdInterval,
f3NtpAccPortFlowPointThresholdVariable,
f3NtpAccPortFlowPointThresholdValueLo, f3NtpAccPortFlowPointThresholdValueHi,
f3NtpAccPortFlowPointThresholdMonValue,
f3NtpNetPortFlowPointStatsIndex, f3NtpNetPortFlowPointStatsIntervalType,
f3NtpNetPortFlowPointStatsValid, f3NtpNetPortFlowPointStatsAction,
f3NtpNetPortFlowPointStatsRequestsDropped,
f3NtpNetPortFlowPointStatsRequestsReceived, f3NtpNetPortFlowPointStatsResponsesTransmitted,
f3NtpNetPortFlowPointHistoryIndex, f3NtpNetPortFlowPointHistoryTime,
f3NtpNetPortFlowPointHistoryValid, f3NtpNetPortFlowPointHistoryAction,
f3NtpNetPortFlowPointHistoryRequestsDropped,
f3NtpNetPortFlowPointHistoryRequestsReceived, f3NtpNetPortFlowPointHistoryResponsesTransmitted,
f3NtpNetPortFlowPointThresholdIndex, f3NtpNetPortFlowPointThresholdInterval,
f3NtpNetPortFlowPointThresholdVariable,
f3NtpNetPortFlowPointThresholdValueLo, f3NtpNetPortFlowPointThresholdValueHi,
f3NtpNetPortFlowPointThresholdMonValue,
f3NtpTrackedClientStatsIndex, f3NtpTrackedClientStatsIntervalType,
f3NtpTrackedClientStatsValid, f3NtpTrackedClientStatsAction,
f3NtpTrackedClientStatsResponsesTransmitted, f3NtpTrackedClientStatsRequestsReceived,
f3NtpTrackedClientHistoryIndex, f3NtpTrackedClientHistoryTime,
f3NtpTrackedClientHistoryValid, f3NtpTrackedClientHistoryAction,
f3NtpTrackedClientHistoryResponsesTransmitted, f3NtpTrackedClientHistoryRequestsReceived,
f3NtpTrackedClientThresholdIndex, f3NtpTrackedClientThresholdInterval,
f3NtpTrackedClientThresholdVariable, f3NtpTrackedClientThresholdValueLo,
f3NtpTrackedClientThresholdValueHi, f3NtpTrackedClientThresholdMonValue
}
STATUS current
DESCRIPTION
"A collection of objects used to manage the F3 NTP Performance data."
::= { f3NtpGroups 2 }
END