* Ericsson IPOS Yaml * Add files via upload * Add files via upload * Add files via upload * Add files via upload * Ericsson IPOS MIBs * Ericsson IPOS - Serial & Hardware detection * Ericsson IPOS - Remove mempool from overview * SSR8020 SNMPrec * Ericsson IPOS SSR 8020 Test * Delete tests/snmpsim/ericsson-ipos_ssr8020.snmpwalk * SSR8020 SNMPrec * Add storage to overview * Move to new SnmpQuery * SnmpQuery() instead of snmp_* * Delete mibs/ericsson directory * Create ERICSSON-TOP-MIB * Add files via upload
178 lines
5.8 KiB
Plaintext
178 lines
5.8 KiB
Plaintext
-- %DNP% $Id: ERICSSON-ROUTER-TC.my,v 1.1.2.8.252.3 2011/02/22 17:26:18 thatcher Exp $
|
|
-- %DNP% $Source: /cvsroot/pkt/sw/se/xc/bsd/config/snmp/mibs/Attic/ERICSSON-ROUTER-TC.my,v $
|
|
-- *****************************************************************
|
|
-- ERICSSON-ROUTER-TC Textual Convention MIB
|
|
--
|
|
-- Copyright (c) 2000, 2002-2009, 2011, 2014, 2015, 2017 Ericsson AB
|
|
-- All rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
|
|
ERICSSON-ROUTER-TC DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
Integer32, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
|
|
eriRouterModules
|
|
FROM ERICSSON-ROUTER-SMI;
|
|
|
|
|
|
eriRouterTC MODULE-IDENTITY
|
|
LAST-UPDATED "201707281800Z" -- Jul 28, 2017
|
|
ORGANIZATION "Ericsson AB."
|
|
CONTACT-INFO
|
|
" Ericsson AB.
|
|
|
|
Postal: 100 Headquarters Dr
|
|
San Jose, CA 95134
|
|
USA
|
|
|
|
Phone: +1 408 750 5000
|
|
Fax: +1 408 750 5599
|
|
"
|
|
DESCRIPTION
|
|
"Defines common textual conventions used in ERICSSON-ROUTER mib
|
|
modules."
|
|
|
|
REVISION "201707281800Z" -- Jul 28, 2017
|
|
DESCRIPTION
|
|
"Updated the description of textual convention: EriRouterCircuitHandle.
|
|
The circuit handler is used internally and not necessary to export the
|
|
internal structure to users."
|
|
|
|
REVISION "201501141800Z" -- Jan 14, 2015
|
|
DESCRIPTION
|
|
"Updated RBN/rbn/Rbn as ERICSSON-ROUTER/eriRouter/EriRouter
|
|
to migrate RBN MIB to ERICSSON MIB."
|
|
|
|
REVISION "201407191700Z" -- July 19, 2014
|
|
DESCRIPTION
|
|
"Added new textual convention: EriRouterSubscriberState."
|
|
|
|
REVISION "201101191800Z" -- Jan 19, 2011
|
|
DESCRIPTION
|
|
"Update CONTACT-INFO & ORGANIZATION. "
|
|
|
|
REVISION "200910201700Z" -- Oct 20, 2009
|
|
DESCRIPTION
|
|
"Added new textual convention: EriRouterUnsigned64 for read-write
|
|
capable 64 bit integer value."
|
|
|
|
REVISION "200406191700Z" -- June 19, 2004
|
|
DESCRIPTION
|
|
"Added new textual convention: EriRouterPortMediumType. Correct
|
|
warnings given by smilint."
|
|
|
|
REVISION "200303171700Z" -- March 17, 2003
|
|
DESCRIPTION
|
|
"Added new textual convention: EriRouterVidOrUntagged."
|
|
|
|
REVISION "200211110000Z" -- November 11, 2002
|
|
DESCRIPTION
|
|
"Moved definitions of EriRouterSlot and EriRouterPort from ERICSSON-ROUTER-PVC-MIB.
|
|
Updated range on EriRouterSlot and EriRouterPort."
|
|
|
|
REVISION "200206260000Z" -- June 26, 2002
|
|
DESCRIPTION
|
|
"Updated CONTACT-INFO. Added new textual conventions:
|
|
EriRouterKBytes and EriRouterPercentage."
|
|
|
|
REVISION "200007140000Z" -- July 14, 2000
|
|
DESCRIPTION
|
|
"Initial version."
|
|
::= { eriRouterModules 2 }
|
|
|
|
|
|
EriRouterCircuitHandle ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "1d:1d:2x-2x-2x"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for individual circuits."
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
|
|
EriRouterKBytes ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Storage size, expressed in units of 1024 bytes."
|
|
SYNTAX Integer32 (0..2147483647)
|
|
|
|
EriRouterPercentage ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d%"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Textual Convention describes an object that stores
|
|
a whole integer percentage value."
|
|
SYNTAX Integer32 (0..100)
|
|
|
|
EriRouterSlot ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The chassis slot number. This is the physical slot
|
|
number as reported in the CLI command 'show hardware'
|
|
on SMS and the CLI command 'show port' on SE."
|
|
SYNTAX Unsigned32 (0..255)
|
|
|
|
EriRouterPort ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The chassis port number. This is the physical port
|
|
number as reported in the CLI command 'show hardware'
|
|
on SMS and the CLI command 'show port' on SE."
|
|
SYNTAX Unsigned32 (0..255)
|
|
|
|
EriRouterVidOrUntagged ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The twelve-bit VLAN Identifer (VID) used to uniquely
|
|
identify the VLAN to which the frame belongs. The VID is
|
|
encoded as an unsigned binary number. An untagged frame
|
|
does not carry any identification of the VLAN to which it
|
|
belongs and is designated with a value of 4096."
|
|
SYNTAX Integer32 (1..4096)
|
|
|
|
EriRouterPortMediumType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Medium type of NAS port."
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
dsl(11),
|
|
cable(12),
|
|
wireless(13),
|
|
satellite(14)
|
|
}
|
|
|
|
EriRouterUnsigned64 ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "8d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unsigned 64 bit integer value is represented as an
|
|
OCTET STRING. This allows an unsigned integer value in
|
|
the range 0..18446744073709551615.
|
|
|
|
The octets are ordered with the first octet containing
|
|
the highest ordered bits of the integer and the 8th octet
|
|
containing the lowest ordered bits, corresponding to
|
|
network byte order."
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
|
|
EriRouterSubscriberState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of subscriber session."
|
|
SYNTAX INTEGER {
|
|
up(9),
|
|
standby-up(13)
|
|
}
|
|
|
|
END
|