* Add support for FiberStore "data center" switches FiberStore has two different model lines of switches, and this adds support for the "data center" line. This was configured and tested against the N5860-48SC model. The MIBs are from FiberStore's website, with the exception of the FS-FIBER-MIB (the website version is a little behind the software, so support sent me an updated version and should be getting it published soon). This does not currently handle 4x10 or 4x25 QSFP+ light levels, as I don't currently have any to test against. * Add test data for fs-switch-dc This is from a production switch, with data filtered to just the FiberStore enterprises OID. * Update fs-switch-dc_fs-switch-dc.json * correct processors warn field name * Update fs-switch-dc_fs-switch-dc.json * Update fs-switch-dc.yaml --------- Co-authored-by: Tony Murray <murraytony@gmail.com>
2434 lines
79 KiB
Plaintext
2434 lines
79 KiB
Plaintext
-- *****************************************************************
|
|
-- FS-SYSTEM-MIB.mib: FS System MIB file
|
|
--
|
|
-- March 2002, Wuzg
|
|
--
|
|
-- Copyright (c) 2002 by FS.COM Inc..
|
|
-- All rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
--
|
|
|
|
FS-SYSTEM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
NOTIFICATION-TYPE,
|
|
Integer32,
|
|
TimeTicks,
|
|
Unsigned32
|
|
FROM SNMPv2-SMI
|
|
DisplayString,
|
|
MacAddress
|
|
FROM SNMPv2-TC
|
|
Gauge
|
|
FROM RFC1155-SMI
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
fsApMacAddr
|
|
FROM FS-AC-MGMT-MIB
|
|
fsMemoryPoolCurrentUtilization
|
|
FROM FS-MEMORY-MIB
|
|
fsCPUUtilization1Min,
|
|
Percent
|
|
FROM FS-PROCESS-MIB
|
|
fsMgmt
|
|
FROM FS-SMI;
|
|
|
|
fsSystemMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200203200000Z"
|
|
ORGANIZATION "FS.COM Inc.."
|
|
CONTACT-INFO
|
|
"
|
|
Tel: 400-865-2852
|
|
|
|
E-mail: https://www.fs.com/live_chat_service_mail.html"
|
|
DESCRIPTION
|
|
"This module defines fs system mibs."
|
|
REVISION "200203200000Z"
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
::= { fsMgmt 1}
|
|
|
|
fsSystemMIBObjects OBJECT IDENTIFIER ::= { fsSystemMIB 1 }
|
|
|
|
fsSystemHwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the string of the Revision number of hardware resides
|
|
on the FastSwitch."
|
|
::= { fsSystemMIBObjects 1 }
|
|
|
|
fsSystemSwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the string of the Revision number of software resides
|
|
on the FastSwitch."
|
|
::= { fsSystemMIBObjects 2 }
|
|
|
|
fsSystemBootVersion OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the string of the Revision number of BOOT software resides
|
|
on the FastSwitch."
|
|
::= { fsSystemMIBObjects 3 }
|
|
|
|
fsSystemSysCtrlVersion OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the string of the Revision number of CTRL software resides
|
|
on the FastSwitch."
|
|
::= { fsSystemMIBObjects 4 }
|
|
|
|
fsSystemParametersSave OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Save all parameters changed in configuration by setting
|
|
this object to any value but 0, set its value to 0 will
|
|
cause no action of agent, otherwise all changes of
|
|
prarameters will be saved for retrive when system is
|
|
reset, if parameter is changed but not saved all changes
|
|
will come to their original value when system down and up
|
|
again, when query always return value 0."
|
|
::= { fsSystemMIBObjects 5 }
|
|
|
|
fsSystemOutBandRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
baud9600 (1),
|
|
baud19200 (2),
|
|
baud38400 (3),
|
|
baud57600 (4),
|
|
baud115200 (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determine the console(OutBand) baud rate :
|
|
9600 - 1,19200 - 2, 38300 - 3, 57600 - 4, 115200 - 5,
|
|
when the console baud rate is other value will return value 0."
|
|
::= { fsSystemMIBObjects 6 }
|
|
|
|
fsSystemReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
restart(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object allow perform soft reset of system by setting its
|
|
value to none zero. if a soft resetis performed, after this
|
|
having completed a warm start trap will send to declare the state
|
|
and when queried will always return 0."
|
|
::= { fsSystemMIBObjects 7 }
|
|
|
|
fsSwitchLayer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
layer2 (1), -- Layer 2 Switch
|
|
layer3 (2), -- Layer 3 Switch
|
|
router(3) -- Router
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Which layer's device the switch in system "
|
|
::= { fsSystemMIBObjects 8 }
|
|
|
|
fsSystemHwPower OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
rpsNoLink(1),
|
|
rpsLinkAndNoPower(2),
|
|
rpsLinkAndReadyForPower(3),
|
|
rpsLinkAndPower(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of power."
|
|
::= { fsSystemMIBObjects 9 }
|
|
|
|
fsSystemHwFan OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
work(1),
|
|
stop(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of fan."
|
|
::= { fsSystemMIBObjects 10 }
|
|
|
|
--The fsSystemOutBandTimeout is obsoleted after 2007.9
|
|
fsSystemOutBandTimeout OBJECT-TYPE
|
|
SYNTAX Integer32(0..3600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The timeout of console.0 indicate that timeout function is disabled."
|
|
::= { fsSystemMIBObjects 11 }
|
|
|
|
--The fsSystemTelnetTimeout is obsoleted after 2007.9
|
|
fsSystemTelnetTimeout OBJECT-TYPE
|
|
SYNTAX Integer32(0..3600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The timeout of telnet.0 indicate that timeout function is disabled."
|
|
::= { fsSystemMIBObjects 12 }
|
|
|
|
fsSystemMainFile OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (1..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the string of the name of main file on the FastSwitch."
|
|
::= { fsSystemMIBObjects 13 }
|
|
|
|
fsSystemCurrentPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the current power of the FastSwitch."
|
|
::= { fsSystemMIBObjects 14 }
|
|
|
|
fsSystemRemainPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the remain power of the FastSwitch."
|
|
::= { fsSystemMIBObjects 15 }
|
|
|
|
fsSystemTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the temperature of the FastSwitch."
|
|
::= { fsSystemMIBObjects 16 }
|
|
|
|
fsSystemElectricalSourceNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the electrical source number of the FastSwitch."
|
|
::= { fsSystemMIBObjects 17 }
|
|
|
|
fsSystemElectricalSourceIsNormalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemElectricalSourceIsNormalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of electrical source entries. Each object displays
|
|
whether different electrical sources are normal or not."
|
|
::= { fsSystemMIBObjects 18 }
|
|
|
|
fsSystemElectricalSourceIsNormalEntry OBJECT-TYPE
|
|
SYNTAX FSSystemElectricalSourceIsNormalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays whether different electrical sources are normal or not."
|
|
INDEX { fsSystemElectricalSourceIsNormalIndex }
|
|
::= { fsSystemElectricalSourceIsNormalTable 1 }
|
|
|
|
FSSystemElectricalSourceIsNormalEntry ::=
|
|
SEQUENCE {
|
|
fsSystemElectricalSourceIsNormalIndex Integer32,
|
|
fsSystemElectricalSourceIsNormal INTEGER,
|
|
fsSystemElectricalSourceName DisplayString
|
|
}
|
|
|
|
fsSystemElectricalSourceIsNormalIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a electrical source."
|
|
::= { fsSystemElectricalSourceIsNormalEntry 1 }
|
|
|
|
fsSystemElectricalSourceIsNormal OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noexist (1), --no exist
|
|
existnopower (2), -- exist no power
|
|
existreadypower (3), --exist ready power
|
|
normal (4), --normal
|
|
powerbutabnormal (5), --power but abnormal
|
|
unknow (6) --unknow
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays whether an electrical source is normal or not."
|
|
::= { fsSystemElectricalSourceIsNormalEntry 2 }
|
|
|
|
fsSystemElectricalSourceName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of electrical source"
|
|
::= { fsSystemElectricalSourceIsNormalEntry 3 }
|
|
|
|
fsSystemCurrentVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the current voltage of the FastSwitch."
|
|
::= { fsSystemMIBObjects 19 }
|
|
|
|
fsSystemFanNUM OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the number of fan on the FastSwitch."
|
|
::= { fsSystemMIBObjects 20 }
|
|
|
|
fsSystemFanIsNormalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemFanIsNormalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of fan entries. Each object displays
|
|
whether different fans are normal or not."
|
|
::= { fsSystemMIBObjects 21 }
|
|
|
|
fsSystemFanIsNormalEntry OBJECT-TYPE
|
|
SYNTAX FSSystemFanIsNormalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays whether different fans are normal or not."
|
|
INDEX { fsSystemFanIsNormalIndex }
|
|
::= { fsSystemFanIsNormalTable 1 }
|
|
|
|
FSSystemFanIsNormalEntry ::=
|
|
SEQUENCE {
|
|
fsSystemFanIsNormalIndex Integer32,
|
|
fsSystemFanIsNormal INTEGER,
|
|
fsSystemFanName DisplayString,
|
|
fsSystemFanSpeed Integer32
|
|
}
|
|
|
|
fsSystemFanIsNormalIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a fan."
|
|
::= { fsSystemFanIsNormalEntry 1 }
|
|
|
|
fsSystemFanIsNormal OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noexist (1), --no exist
|
|
existnopower (2), -- exist no power
|
|
existreadypower (3), --exist ready power
|
|
normal (4), --normal
|
|
powerbutabnormal (5), --power but abnormal
|
|
unknow (6) --unknow
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays whether an fan is normal or not."
|
|
::= { fsSystemFanIsNormalEntry 2 }
|
|
|
|
fsSystemFanName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of fan"
|
|
::= { fsSystemFanIsNormalEntry 3 }
|
|
|
|
fsSystemFanSpeed OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the fan's speed."
|
|
::= { fsSystemFanIsNormalEntry 4 }
|
|
|
|
fsSystemReloadTimeRemain OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the remain time of reloading on the FastSwitch."
|
|
::= { fsSystemMIBObjects 22 }
|
|
|
|
fsSystemTemperatureTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemTemperatureEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of temperature entries. Each object displays
|
|
the temperature information."
|
|
::= { fsSystemMIBObjects 23 }
|
|
|
|
fsSystemTemperatureEntry OBJECT-TYPE
|
|
SYNTAX FSSystemTemperatureEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays the temperature information."
|
|
INDEX { fsSystemTemperatureIndex }
|
|
::= { fsSystemTemperatureTable 1 }
|
|
|
|
FSSystemTemperatureEntry ::=
|
|
SEQUENCE {
|
|
fsSystemTemperatureIndex Integer32,
|
|
fsSystemTemperatureName DisplayString,
|
|
fsSystemTemperatureCurrent Integer32,
|
|
fsSystemTemperatureWarningVaule Integer32,
|
|
fsSystemTemperatureCritialVaule Integer32
|
|
}
|
|
|
|
fsSystemTemperatureIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a device's temperature information."
|
|
::= { fsSystemTemperatureEntry 1 }
|
|
|
|
fsSystemTemperatureName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual name assigned to a temperature chip"
|
|
::= { fsSystemTemperatureEntry 2 }
|
|
|
|
fsSystemTemperatureCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the current temperature of the FastSwitch.The temperature display
|
|
is not supported for the current temperature returns to 0."
|
|
::= { fsSystemTemperatureEntry 3 }
|
|
|
|
fsSystemTemperatureWarningVaule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The first warning of temperature of the device CPU."
|
|
::= { fsSystemTemperatureEntry 4 }
|
|
|
|
fsSystemTemperatureCritialVaule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The second warning of temperature of the device CPU."
|
|
::= { fsSystemTemperatureEntry 5 }
|
|
|
|
fsSystemSerialno OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the string of the serial number resides on the FastSwitch.
|
|
Or return the serial number resides on the current master engine of a chassis device."
|
|
::= { fsSystemMIBObjects 24 }
|
|
|
|
fsSystemVersionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemVersionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of system version entries. Each object displays
|
|
the system version information."
|
|
::= { fsSystemMIBObjects 25 }
|
|
|
|
fsSystemVersionEntry OBJECT-TYPE
|
|
SYNTAX FSSystemVersionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays the system version information."
|
|
INDEX { fsSystemVersionIndex }
|
|
::= { fsSystemVersionTable 1 }
|
|
|
|
FSSystemVersionEntry ::=
|
|
SEQUENCE {
|
|
fsSystemVersionIndex Unsigned32,
|
|
fsSystemVersionName DisplayString,
|
|
fsSystemVersionSwBoot DisplayString,
|
|
fsSystemVersionSwCtrl DisplayString,
|
|
fsSystemVersionSwMain DisplayString,
|
|
fsSystemVersionHw DisplayString,
|
|
fsSystemVersionSerialno DisplayString
|
|
}
|
|
|
|
fsSystemVersionIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a device's system version information."
|
|
::= { fsSystemVersionEntry 1 }
|
|
|
|
fsSystemVersionName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual name assigned to a system version chip"
|
|
::= { fsSystemVersionEntry 2 }
|
|
|
|
fsSystemVersionSwBoot OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the software boot system version of the FastSwitch."
|
|
::= { fsSystemVersionEntry 3 }
|
|
|
|
fsSystemVersionSwCtrl OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the software ctrl system version of the FastSwitch."
|
|
::= { fsSystemVersionEntry 4 }
|
|
|
|
fsSystemVersionSwMain OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the software main system version of the FastSwitch."
|
|
::= { fsSystemVersionEntry 5 }
|
|
|
|
fsSystemVersionHw OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the hardware system version of the FastSwitch."
|
|
::= { fsSystemVersionEntry 6 }
|
|
|
|
fsSystemVersionSerialno OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the serial number of the FastSwitch."
|
|
::= { fsSystemVersionEntry 7 }
|
|
|
|
--System models added 2010-05
|
|
fsSystemSysModel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the SysModel of equipment."
|
|
::={ fsSystemMIBObjects 26 }
|
|
|
|
fsSystemUptime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the SysUptime of equipment,unit is seconds."
|
|
::={ fsSystemMIBObjects 27 }
|
|
|
|
--System Sample Time 2010-05
|
|
fsSystemSampleTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sampling duration."
|
|
::={ fsSystemMIBObjects 28 }
|
|
|
|
fsSystemStatWindowTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Stating duration."
|
|
::={ fsSystemMIBObjects 29 }
|
|
|
|
fsSystemManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the string of the manufacturer."
|
|
::= { fsSystemMIBObjects 30 }
|
|
|
|
fsSystemCurrentTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the current time of the system."
|
|
::= { fsSystemMIBObjects 31 }
|
|
|
|
fsSystemWarnResendTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the resending time of warn trap of the system."
|
|
::= { fsSystemMIBObjects 32 }
|
|
|
|
fsSystemSoftwareName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the software name of the system."
|
|
::= { fsSystemMIBObjects 33 }
|
|
|
|
fsSystemSoftwareManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the software manufacturer of the system."
|
|
::= { fsSystemMIBObjects 34 }
|
|
|
|
fsSystemCpuType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the cpu type infomation of the system."
|
|
::= { fsSystemMIBObjects 35 }
|
|
|
|
fsSystemMemoryType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the memory type of the system."
|
|
::= { fsSystemMIBObjects 36 }
|
|
|
|
fsSystemMemorySize OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the memory card storage of the system."
|
|
::= { fsSystemMIBObjects 37 }
|
|
|
|
fsSystemFlashSize OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the flash size of the system."
|
|
::= { fsSystemMIBObjects 38 }
|
|
|
|
--lank ap 2010-7
|
|
fsSystemLankApTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemLankApEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of lank ap system entries. Each object displays
|
|
the lank ap system information."
|
|
::= { fsSystemMIBObjects 39 }
|
|
|
|
fsSystemLankApEntry OBJECT-TYPE
|
|
SYNTAX FSSystemLankApEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays the lank ap system information."
|
|
INDEX { fsSystemLankApMacAddr }
|
|
::= { fsSystemLankApTable 1 }
|
|
|
|
FSSystemLankApEntry ::=
|
|
SEQUENCE {
|
|
fsSystemLankApMacAddr MacAddress,
|
|
fsSystemLankApStatWindowTime Integer32,
|
|
fsSystemLankApSampleTime Integer32,
|
|
fsSystemLankApReset INTEGER,
|
|
fsSystemLankApSoftwareName DisplayString,
|
|
fsSystemLankApSwVersion DisplayString,
|
|
fsSystemLankApSoftwareManufacturer DisplayString,
|
|
fsSystemLankApCpuType DisplayString,
|
|
fsSystemLankApMemoryType DisplayString,
|
|
fsSystemLankApMemorySize Gauge,
|
|
fsSystemLankAPFlashSize Gauge,
|
|
fsSystemLankApManufacturer DisplayString,
|
|
fsSystemLankApSerialno DisplayString,
|
|
fsSystemLankApSysModel DisplayString,
|
|
fsSystemLankApUptime INTEGER,
|
|
fsSystemLankApAccurateUptime TimeTicks,
|
|
fsSystemLankApHwVersion DisplayString
|
|
}
|
|
|
|
fsSystemLankApMacAddr OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents lank ap system information."
|
|
::= { fsSystemLankApEntry 1 }
|
|
|
|
fsSystemLankApStatWindowTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Stating duration of lank ap."
|
|
::={ fsSystemLankApEntry 2 }
|
|
|
|
fsSystemLankApSampleTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sampling duration of lank ap."
|
|
::={ fsSystemLankApEntry 3 }
|
|
|
|
fsSystemLankApReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
restart(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object allow perform soft reset of lank ap system by setting
|
|
its value to none zero. if a soft resetis performed, after this
|
|
having completed a warm start trap will send to declare the state
|
|
and when queried will always return 0."
|
|
::= { fsSystemLankApEntry 4 }
|
|
|
|
fsSystemLankApSoftwareName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the software name of the lank ap system."
|
|
::= { fsSystemLankApEntry 5 }
|
|
|
|
fsSystemLankApSwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the string of the Revision number of software resides
|
|
on the lank ap FastSwitch."
|
|
::= { fsSystemLankApEntry 6 }
|
|
|
|
fsSystemLankApSoftwareManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the software manufacturer of the lank ap system."
|
|
::= { fsSystemLankApEntry 7 }
|
|
|
|
fsSystemLankApCpuType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the cpu type infomation of the lank ap system."
|
|
::= { fsSystemLankApEntry 8 }
|
|
|
|
fsSystemLankApMemoryType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the memory type of the lank ap system."
|
|
::= { fsSystemLankApEntry 9 }
|
|
|
|
fsSystemLankApMemorySize OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the memory card storage of the lank ap system."
|
|
::= { fsSystemLankApEntry 10 }
|
|
|
|
fsSystemLankAPFlashSize OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the flash size of the lank ap system."
|
|
::= { fsSystemLankApEntry 11 }
|
|
|
|
fsSystemLankApManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the string of the manufacturer of lank ap."
|
|
::= { fsSystemLankApEntry 12}
|
|
|
|
fsSystemLankApSerialno OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the string of the serial number resides
|
|
on the lank ap FastSwitch."
|
|
::= { fsSystemLankApEntry 13 }
|
|
|
|
fsSystemLankApSysModel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the SysModel of lank ap equipment."
|
|
::={ fsSystemLankApEntry 14 }
|
|
|
|
fsSystemLankApUptime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the SysUptime of lank ap equipment."
|
|
::={ fsSystemLankApEntry 15 }
|
|
|
|
fsSystemLankApAccurateUptime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the accurate system Uptime of ap equipment,unit is ticks"
|
|
::={ fsSystemLankApEntry 16 }
|
|
|
|
fsSystemLankApHwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE (1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the string of the Revision number of hardware resides
|
|
on the lank ap FastSwitch."
|
|
::= { fsSystemLankApEntry 17 }
|
|
|
|
|
|
fsSystemBoardTemperatureTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemBoardTemperatureEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of board temperature entries. Each object displays
|
|
the board temperature information."
|
|
::= { fsSystemMIBObjects 40 }
|
|
|
|
fsSystemBoardTemperatureEntry OBJECT-TYPE
|
|
SYNTAX FSSystemBoardTemperatureEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays the board temperature information."
|
|
INDEX { fsSystemBoardTemperatureIndex }
|
|
::= { fsSystemBoardTemperatureTable 1 }
|
|
|
|
FSSystemBoardTemperatureEntry ::=
|
|
SEQUENCE {
|
|
fsSystemBoardTemperatureIndex Integer32,
|
|
fsSystemBoardTemperatureName DisplayString,
|
|
fsSystemBoardTemperatureCurrent Integer32
|
|
}
|
|
|
|
fsSystemBoardTemperatureIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a device's board temperature information."
|
|
::= { fsSystemBoardTemperatureEntry 1 }
|
|
|
|
fsSystemBoardTemperatureName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual name assigned to a board temperature chip"
|
|
::= { fsSystemBoardTemperatureEntry 2 }
|
|
|
|
fsSystemBoardTemperatureCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the current board temperature of the FastSwitch.The temperature display
|
|
is not supported for the current temperature returns to 0."
|
|
::= { fsSystemBoardTemperatureEntry 3 }
|
|
|
|
fsSystemElectricalInformationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemElectricalInformationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of electrical entries. Each object displays the electrical information."
|
|
::= { fsSystemMIBObjects 41 }
|
|
|
|
fsSystemElectricalInformationEntry OBJECT-TYPE
|
|
SYNTAX FSSystemElectricalInformationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays the electrical information."
|
|
INDEX {fsSystemElectricalInformationDeviceIndex, fsSystemElectricalInformationIndex }
|
|
::= { fsSystemElectricalInformationTable 1 }
|
|
|
|
FSSystemElectricalInformationEntry ::=
|
|
SEQUENCE {
|
|
fsSystemElectricalInformationDeviceIndex Integer32,
|
|
fsSystemElectricalInformationIndex Integer32,
|
|
fsSystemElectricalInformationStatus INTEGER,
|
|
fsSystemElectricalInformationType DisplayString,
|
|
fsSystemElectricalInformationAttribute DisplayString,
|
|
fsSystemElectricalInformationSofeVersion DisplayString,
|
|
fsSystemElectricalInformationHardwareVersion DisplayString,
|
|
fsSystemElectricalInformationSerial DisplayString,
|
|
fsSystemElectricalInformationProductionDate DisplayString,
|
|
fsSystemElectricalInformationRatedPower Integer32,
|
|
fsSystemElectricalInformationInVoltage Integer32,
|
|
fsSystemElectricalInformationInCurrent Integer32,
|
|
fsSystemElectricalInformationOutVoltage Integer32,
|
|
fsSystemElectricalInformationOutCurrent Integer32,
|
|
fsSystemElectricalInformationOutPower Integer32,
|
|
fsSystemElectricalInformationTemperature Integer32,
|
|
fsSystemElectricalInformationAirflowCoexist DisplayString,
|
|
fsSystemElectricalInformationWarningStatus DisplayString
|
|
}
|
|
|
|
fsSystemElectricalInformationDeviceIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a device."
|
|
::= { fsSystemElectricalInformationEntry 1 }
|
|
|
|
fsSystemElectricalInformationIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a electriacl."
|
|
::= { fsSystemElectricalInformationEntry 2 }
|
|
|
|
fsSystemElectricalInformationStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noexist (1), --no exist
|
|
existnopower (2), -- exist no power
|
|
existreadypower (3), --exist ready power
|
|
normal (4), --normal
|
|
powerbutabnormal (5), --power but abnormal
|
|
unknow (6) --unknow
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays whether an electrical source is normal or not.
|
|
If the electrical is no exist, the other of electrical information maybe
|
|
return nothing information and 0."
|
|
::= { fsSystemElectricalInformationEntry 3 }
|
|
|
|
fsSystemElectricalInformationType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the type of the electrical. If the device is no support this information,
|
|
This object will return nothing information."
|
|
::= { fsSystemElectricalInformationEntry 4 }
|
|
|
|
fsSystemElectricalInformationAttribute OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays attribute of the electrical. If the device is no support
|
|
this information, This object will return nothing information."
|
|
::= { fsSystemElectricalInformationEntry 5 }
|
|
|
|
fsSystemElectricalInformationSofeVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the sofe version of the electrical. If the device is no support
|
|
this information, This object will return nothing information."
|
|
::= { fsSystemElectricalInformationEntry 6}
|
|
|
|
fsSystemElectricalInformationHardwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the hardware version of the electrical. If the device is no support
|
|
this information, This object will return nothing information."
|
|
::= { fsSystemElectricalInformationEntry 7 }
|
|
|
|
fsSystemElectricalInformationSerial OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the serial of the electrical. If the device is no support
|
|
this information, This object will return nothing information."
|
|
::= { fsSystemElectricalInformationEntry 8 }
|
|
|
|
fsSystemElectricalInformationProductionDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the productiron date of the electrical. If the device is no support
|
|
this information, This object will return nothing information."
|
|
::= { fsSystemElectricalInformationEntry 9 }
|
|
|
|
fsSystemElectricalInformationRatedPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the rated power(Unit: W) of the electrical. If the device is no support
|
|
this information, This object will return 0."
|
|
::= { fsSystemElectricalInformationEntry 10 }
|
|
|
|
fsSystemElectricalInformationInVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the input voltage(Unit: V) of the electrical. If the device is no support
|
|
this information, This object will return 0."
|
|
::= { fsSystemElectricalInformationEntry 11 }
|
|
|
|
fsSystemElectricalInformationInCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the input current(Unit: mA) of the electrical. If the device is no support
|
|
this information, This object will return 0."
|
|
::= { fsSystemElectricalInformationEntry 12 }
|
|
|
|
fsSystemElectricalInformationOutVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the output voltage(Unit: V) of the electrical. If the device is no support
|
|
this information, This object will return 0."
|
|
::= { fsSystemElectricalInformationEntry 13 }
|
|
|
|
fsSystemElectricalInformationOutCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the output current(Unit: mA) of the electrical. If the device is no support
|
|
this information, This object will return 0."
|
|
::= { fsSystemElectricalInformationEntry 14 }
|
|
|
|
fsSystemElectricalInformationOutPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the output power(Unit: W) of the electrical. If the device is no support
|
|
this information, This object will return 0."
|
|
::= { fsSystemElectricalInformationEntry 15 }
|
|
|
|
fsSystemElectricalInformationTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the temperature(Unit: C) of the electrical. If the device is no support
|
|
this information, This object will return -255."
|
|
::= { fsSystemElectricalInformationEntry 16 }
|
|
|
|
fsSystemElectricalInformationAirflowCoexist OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the airflow coexist of the electrical. If the device is no support
|
|
this information, This object will return nothing information."
|
|
::= { fsSystemElectricalInformationEntry 17 }
|
|
|
|
fsSystemElectricalInformationWarningStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the warning status of the electrical. If the device is no support
|
|
this information, This object will return nothing information."
|
|
::= { fsSystemElectricalInformationEntry 18 }
|
|
|
|
fsSystemFanInformationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemFanInformationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of fan entries. Each object displays the fan information."
|
|
::= { fsSystemMIBObjects 42 }
|
|
|
|
fsSystemFanInformationEntry OBJECT-TYPE
|
|
SYNTAX FSSystemFanInformationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays the fan information."
|
|
INDEX { fsSystemFanInformationDeviceIndex , fsSystemFanInformationFanIndex}
|
|
::= {fsSystemFanInformationTable 1 }
|
|
|
|
FSSystemFanInformationEntry ::=
|
|
SEQUENCE {
|
|
fsSystemFanInformationDeviceIndex Integer32,
|
|
fsSystemFanInformationFanIndex Integer32,
|
|
fsSystemFanInformationStatus INTEGER,
|
|
fsSystemFanInformationType DisplayString,
|
|
fsSystemFanInformationAttribute DisplayString,
|
|
fsSystemFanInformationSofeVersion DisplayString,
|
|
fsSystemFanInformationFirmwareVersion DisplayString,
|
|
fsSystemFanInformationHardwareVersion DisplayString,
|
|
fsSystemFanInformationSerial DisplayString,
|
|
fsSystemFanInformationProductionDate DisplayString,
|
|
fsSystemFanInformationTemperature Integer32,
|
|
fsSystemFanInformationNumber Integer32,
|
|
fsSystemFanInformationAirflowCoexist DisplayString,
|
|
fsSystemFanInformationWarningStatus DisplayString
|
|
}
|
|
|
|
fsSystemFanInformationDeviceIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a device."
|
|
::= { fsSystemFanInformationEntry 1 }
|
|
|
|
fsSystemFanInformationFanIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a fan device."
|
|
::= { fsSystemFanInformationEntry 2 }
|
|
|
|
fsSystemFanInformationStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noexist (1), --no exist
|
|
existnopower (2), --exist no power
|
|
existreadypower (3), --exist ready power
|
|
normal (4), --normal
|
|
powerbutabnormal (5), --power but abnormal
|
|
unknow (6) --unknow
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays whether an fan device source is exist or not.
|
|
If the fan device is no exist, the other of fan information maybe
|
|
return nothing information and 0."
|
|
::= { fsSystemFanInformationEntry 3 }
|
|
|
|
fsSystemFanInformationType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the type of the fan. If the device is no support this information,
|
|
This object will return nothing information."
|
|
::= { fsSystemFanInformationEntry 4 }
|
|
|
|
fsSystemFanInformationAttribute OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays attribute of the fan. If the device is no support
|
|
this information, This object will return nothing information."
|
|
::= { fsSystemFanInformationEntry 5 }
|
|
|
|
fsSystemFanInformationSofeVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the sofe version of the fan. If the device is no support
|
|
this information, This object will return nothing information."
|
|
::= { fsSystemFanInformationEntry 6}
|
|
|
|
fsSystemFanInformationFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the firmware version of the fan. If the device is no support
|
|
this information, This object will return nothing information."
|
|
::= { fsSystemFanInformationEntry 7 }
|
|
|
|
fsSystemFanInformationHardwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the hardware version of the fan. If the device is no support
|
|
this information, This object will return nothing information."
|
|
::= { fsSystemFanInformationEntry 8 }
|
|
|
|
fsSystemFanInformationSerial OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the serial of the fan. If the device is no support
|
|
this information, This object will return nothing information."
|
|
::= { fsSystemFanInformationEntry 9 }
|
|
|
|
fsSystemFanInformationProductionDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the productiron date of the fan. If the device is no support
|
|
this information, This object will return nothing information."
|
|
::= { fsSystemFanInformationEntry 10 }
|
|
|
|
fsSystemFanInformationTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the temperature of the fan device. If the device is no support
|
|
this information, This object will return -255."
|
|
::= { fsSystemFanInformationEntry 11 }
|
|
|
|
fsSystemFanInformationNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the number of the fan device. If the device is no support
|
|
this information, This object will return 0."
|
|
::= { fsSystemFanInformationEntry 12 }
|
|
|
|
fsSystemFanInformationAirflowCoexist OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the airflow coexist of the fan device. If the device is no support
|
|
this information, This object will return nothing information."
|
|
::= { fsSystemFanInformationEntry 13 }
|
|
|
|
fsSystemFanInformationWarningStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the warning status of the fan device. If the device is no support
|
|
this information, This object will return nothing information."
|
|
::= { fsSystemFanInformationEntry 14 }
|
|
|
|
fsSystemFanStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemFanStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of fan status entries. Each object displays the fan status information."
|
|
::= { fsSystemMIBObjects 43 }
|
|
|
|
fsSystemFanStatusEntry OBJECT-TYPE
|
|
SYNTAX FSSystemFanStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays the fan status information."
|
|
INDEX { fsSystemFanStatusDeviceIndex,
|
|
fsSystemFanStatusFanIndex,
|
|
fsSystemFanStatusIndex }
|
|
::= {fsSystemFanStatusTable 1 }
|
|
|
|
FSSystemFanStatusEntry ::=
|
|
SEQUENCE {
|
|
fsSystemFanStatusDeviceIndex Integer32,
|
|
fsSystemFanStatusFanIndex Integer32,
|
|
fsSystemFanStatusIndex Integer32,
|
|
fsSystemFanStatus INTEGER,
|
|
fsSystemFanStatusLevel Integer32,
|
|
fsSystemFanStatusSpeed Integer32
|
|
}
|
|
|
|
fsSystemFanStatusDeviceIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a device."
|
|
::= { fsSystemFanStatusEntry 1 }
|
|
|
|
fsSystemFanStatusFanIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a fan device."
|
|
::= { fsSystemFanStatusEntry 2 }
|
|
|
|
fsSystemFanStatusIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a fan."
|
|
::= { fsSystemFanStatusEntry 3 }
|
|
|
|
fsSystemFanStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noexist (1), --no exist
|
|
existnopower (2), --exist no power
|
|
existreadypower (3), --exist ready power
|
|
normal (4), --normal
|
|
powerbutabnormal (5), --power but abnormal
|
|
unknow (6) --unknow
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays whether an fan is normal or not."
|
|
::= { fsSystemFanStatusEntry 4 }
|
|
|
|
fsSystemFanStatusLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays the level of the fan speed. If the device is no support this information,
|
|
This object will return 0."
|
|
::= { fsSystemFanStatusEntry 5 }
|
|
|
|
fsSystemFanStatusSpeed OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object displays fan speed(rpm). If the device is no support
|
|
this information, This object will return nothing information."
|
|
::= { fsSystemFanStatusEntry 6 }
|
|
|
|
fsSystemMultipleTemperatureTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemMultipleTemperatureEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of multiple temperature entries. Each object displays
|
|
the multiple temperature information."
|
|
::= { fsSystemMIBObjects 44 }
|
|
|
|
fsSystemMultipleTemperatureEntry OBJECT-TYPE
|
|
SYNTAX FSSystemMultipleTemperatureEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays the multiple temperature information."
|
|
INDEX { fsSystemMultipleTemperatureDeviceIndex,
|
|
fsSystemMultipleTemperatureSlotIndex,
|
|
fsSystemMultipleTemperatureIndex }
|
|
::= { fsSystemMultipleTemperatureTable 1 }
|
|
|
|
FSSystemMultipleTemperatureEntry ::=
|
|
SEQUENCE {
|
|
fsSystemMultipleTemperatureDeviceIndex Integer32,
|
|
fsSystemMultipleTemperatureSlotIndex Integer32,
|
|
fsSystemMultipleTemperatureIndex Integer32,
|
|
fsSystemMultipleTemperatureName DisplayString,
|
|
fsSystemMultipleTemperatureCurrent Integer32,
|
|
fsSystemMultipleTemperatureWarning Integer32,
|
|
fsSystemMultipleTemperatureCritical Integer32
|
|
}
|
|
|
|
fsSystemMultipleTemperatureDeviceIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a device."
|
|
::= { fsSystemMultipleTemperatureEntry 1 }
|
|
|
|
fsSystemMultipleTemperatureSlotIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a slot device."
|
|
::= { fsSystemMultipleTemperatureEntry 2 }
|
|
|
|
fsSystemMultipleTemperatureIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents a device's multiple temperature information."
|
|
::= { fsSystemMultipleTemperatureEntry 3 }
|
|
|
|
fsSystemMultipleTemperatureName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual name assigned to a multiple temperature chip"
|
|
::= { fsSystemMultipleTemperatureEntry 4 }
|
|
|
|
fsSystemMultipleTemperatureCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the current multiple temperature of the FastSwitch.The temperature display
|
|
is not supported for the current temperature returns to -255."
|
|
::= { fsSystemMultipleTemperatureEntry 5 }
|
|
|
|
fsSystemMultipleTemperatureWarning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the warning multiple temperature of the FastSwitch.The temperature display
|
|
is not supported for the warning temperature returns to -255."
|
|
::= { fsSystemMultipleTemperatureEntry 6 }
|
|
|
|
fsSystemMultipleTemperatureCritical OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the critical multiple temperature of the FastSwitch.The temperature display
|
|
is not supported for the critical temperature returns to -255."
|
|
::= { fsSystemMultipleTemperatureEntry 7 }
|
|
|
|
fsSystemAccurateUptime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the accurate system Uptime of equipment,unit is ticks."
|
|
::={ fsSystemMIBObjects 45 }
|
|
|
|
fsSystemPowerIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of power"
|
|
::= { fsSystemMIBObjects 46 }
|
|
|
|
fsSystemSwitchID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Switch id in VSU"
|
|
::= { fsSystemMIBObjects 47 }
|
|
|
|
fsSystemApDeviceDescriptionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemApDeviceDescriptionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of lank ap system entries. Each object displays
|
|
the lank ap system information."
|
|
::= { fsSystemMIBObjects 48 }
|
|
|
|
fsSystemApDeviceDescriptionEntry OBJECT-TYPE
|
|
SYNTAX FSSystemApDeviceDescriptionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays the ap Device Description."
|
|
INDEX { fsSystemApDescMacAddr }
|
|
::= { fsSystemApDeviceDescriptionTable 1 }
|
|
|
|
FSSystemApDeviceDescriptionEntry ::=
|
|
SEQUENCE {
|
|
fsSystemApDescMacAddr MacAddress,
|
|
fsSystemApMemoryType INTEGER,
|
|
fsSystemApMemorySize Gauge,
|
|
fsSystemAPFlashType INTEGER,
|
|
fsSystemAPFlashSize Gauge,
|
|
fsSystemApNVRAMSize Gauge,
|
|
fsSystemApCFSize Gauge,
|
|
fsSystemApCPUType DisplayString
|
|
}
|
|
|
|
fsSystemApDescMacAddr OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents ap system information."
|
|
::= { fsSystemApDeviceDescriptionEntry 1 }
|
|
|
|
fsSystemApMemoryType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
reserved(0),
|
|
sdram(1),
|
|
ddram(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the memory type of the lank ap system."
|
|
::= { fsSystemApDeviceDescriptionEntry 2 }
|
|
|
|
fsSystemApMemorySize OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the memory card storage of the lank ap system, unit is MB."
|
|
::= { fsSystemApDeviceDescriptionEntry 3 }
|
|
|
|
fsSystemAPFlashType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
reserved(0),
|
|
nor(1),
|
|
non-nor(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents ap system information."
|
|
::= { fsSystemApDeviceDescriptionEntry 4 }
|
|
|
|
fsSystemAPFlashSize OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the flash size of the lank ap system, unit is MB."
|
|
::= { fsSystemApDeviceDescriptionEntry 5 }
|
|
|
|
fsSystemApNVRAMSize OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the NVRAM size of the lank ap system, unit is MB."
|
|
::= { fsSystemApDeviceDescriptionEntry 6 }
|
|
|
|
fsSystemApCFSize OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the CF size of the lank ap system, unit is MB."
|
|
::= { fsSystemApDeviceDescriptionEntry 7 }
|
|
|
|
fsSystemApCPUType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the cpu type of the lank ap system."
|
|
::= { fsSystemApDeviceDescriptionEntry 8 }
|
|
|
|
fsSystemApDeviceStatisticsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemApDeviceStatisticsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of lank ap system entries. Each object displays
|
|
the lank ap system information."
|
|
::= { fsSystemMIBObjects 49 }
|
|
|
|
fsSystemApDeviceStatisticsEntry OBJECT-TYPE
|
|
SYNTAX FSSystemApDeviceStatisticsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays the ap Device Statistics."
|
|
INDEX { fsSystemApStatMacAddr }
|
|
::= { fsSystemApDeviceStatisticsTable 1 }
|
|
|
|
FSSystemApDeviceStatisticsEntry ::=
|
|
SEQUENCE {
|
|
fsSystemApStatMacAddr MacAddress,
|
|
fsSystemApInterfaceNum Integer32,
|
|
fsSystemApUptime TimeTicks,
|
|
fsSystemApCPUUtilizationCurrent Percent,
|
|
fsSystemApCPUUtilizationAverage Percent,
|
|
fsSystemApMemoryPoolCurrentUtilization Percent,
|
|
fsSystemApMemoryPoolAverageUtilization Percent,
|
|
fsSystemApFlashFreeSize Unsigned32,
|
|
fsSystemAPDeviceTemperature Integer32
|
|
}
|
|
|
|
fsSystemApStatMacAddr OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely represents ap system information."
|
|
::= { fsSystemApDeviceStatisticsEntry 1 }
|
|
|
|
fsSystemApInterfaceNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the interface number of the lank ap system."
|
|
::= { fsSystemApDeviceStatisticsEntry 2 }
|
|
|
|
fsSystemApUptime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the SysUptime of lank ap equipment, unit is ticks."
|
|
::= { fsSystemApDeviceStatisticsEntry 3 }
|
|
|
|
fsSystemApCPUUtilizationCurrent OBJECT-TYPE
|
|
SYNTAX Percent
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the collection of current lank ap cpu using rate."
|
|
::= { fsSystemApDeviceStatisticsEntry 4 }
|
|
|
|
fsSystemApCPUUtilizationAverage OBJECT-TYPE
|
|
SYNTAX Percent
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the average cpu using rate currently."
|
|
::= { fsSystemApDeviceStatisticsEntry 5 }
|
|
|
|
fsSystemApMemoryPoolCurrentUtilization OBJECT-TYPE
|
|
SYNTAX Percent
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the memory pool utilization currently."
|
|
::= { fsSystemApDeviceStatisticsEntry 6 }
|
|
|
|
fsSystemApMemoryPoolAverageUtilization OBJECT-TYPE
|
|
SYNTAX Percent
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the average memory pool utilization currently."
|
|
::= { fsSystemApDeviceStatisticsEntry 7 }
|
|
|
|
fsSystemApFlashFreeSize OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the free size of the flash device, unit is MB."
|
|
::= { fsSystemApDeviceStatisticsEntry 8 }
|
|
|
|
fsSystemAPDeviceTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the temperature of the ap.But the ap is no support
|
|
this information, so it will return 35 in perpetuity"
|
|
::= { fsSystemApDeviceStatisticsEntry 9 }
|
|
|
|
fsSystemUptimeMsLow OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the equipment SysUptime Low 32-bit,unit is tick."
|
|
::={ fsSystemMIBObjects 50 }
|
|
|
|
fsSystemUptimeMsHigh OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the equipment SysUptime High 32-bit,unit is tick."
|
|
::={ fsSystemMIBObjects 51 }
|
|
|
|
fsSystemFanSNTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemFanSNEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of fan's serial number"
|
|
::= { fsSystemMIBObjects 52 }
|
|
|
|
fsSystemFanSNEntry OBJECT-TYPE
|
|
SYNTAX FSSystemFanSNEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays fan SN."
|
|
INDEX { fsSystemFanPadIndex }
|
|
::= { fsSystemFanSNTable 1 }
|
|
|
|
FSSystemFanSNEntry ::=
|
|
SEQUENCE {
|
|
fsSystemFanPadIndex Integer32,
|
|
fsSystemFanPadName DisplayString,
|
|
fsSystemFanPadSN DisplayString
|
|
}
|
|
|
|
fsSystemFanPadIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the index of the fan pad."
|
|
::= { fsSystemFanSNEntry 1 }
|
|
|
|
fsSystemFanPadName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the name of the fan pad."
|
|
::= { fsSystemFanSNEntry 2 }
|
|
|
|
fsSystemFanPadSN OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the SN of the fan pad."
|
|
::= { fsSystemFanSNEntry 3 }
|
|
|
|
fsSystemDsfSNTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemDsfSNEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of dsf's serial number"
|
|
::= { fsSystemMIBObjects 53 }
|
|
|
|
fsSystemDsfSNEntry OBJECT-TYPE
|
|
SYNTAX FSSystemDsfSNEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays dsf SN."
|
|
INDEX { fsSystemDsfIndex }
|
|
::= { fsSystemDsfSNTable 1 }
|
|
|
|
FSSystemDsfSNEntry ::=
|
|
SEQUENCE {
|
|
fsSystemDsfIndex Integer32,
|
|
fsSystemDsfName DisplayString,
|
|
fsSystemDsfSN DisplayString
|
|
}
|
|
|
|
fsSystemDsfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the index of the dsf."
|
|
::= { fsSystemDsfSNEntry 1 }
|
|
|
|
fsSystemDsfName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the name of the dsf."
|
|
::= { fsSystemDsfSNEntry 2 }
|
|
|
|
fsSystemDsfSN OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the SN of the dsf."
|
|
::= { fsSystemDsfSNEntry 3 }
|
|
|
|
fsSystemPowerSNTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemPowerSNEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of power's serial number"
|
|
::= { fsSystemMIBObjects 54 }
|
|
|
|
fsSystemPowerSNEntry OBJECT-TYPE
|
|
SYNTAX FSSystemPowerSNEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays power SN."
|
|
INDEX { fsSystemPowerSNIndex }
|
|
::= { fsSystemPowerSNTable 1 }
|
|
|
|
FSSystemPowerSNEntry ::=
|
|
SEQUENCE {
|
|
fsSystemPowerSNIndex Integer32,
|
|
fsSystemPowerSNName DisplayString,
|
|
fsSystemPowerSN DisplayString
|
|
}
|
|
|
|
fsSystemPowerSNIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the index of the power."
|
|
::= { fsSystemPowerSNEntry 1 }
|
|
|
|
fsSystemPowerSNName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the name of the power."
|
|
::= { fsSystemPowerSNEntry 2 }
|
|
|
|
fsSystemPowerSN OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the SN of the power."
|
|
::= { fsSystemPowerSNEntry 3 }
|
|
|
|
fsSystemFanPad1SpeedTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemFanPad1SpeedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of fan's speed on fan pad1."
|
|
::= { fsSystemMIBObjects 55 }
|
|
|
|
fsSystemFanPad1SpeedEntry OBJECT-TYPE
|
|
SYNTAX FSSystemFanPad1SpeedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays fan's speed on same fan pad"
|
|
INDEX { fsSystemOamFanPad1Index }
|
|
::= { fsSystemFanPad1SpeedTable 1 }
|
|
|
|
FSSystemFanPad1SpeedEntry ::=
|
|
SEQUENCE {
|
|
fsSystemOamFanPad1Index Integer32,
|
|
fsSystemOamFanPad1Name DisplayString,
|
|
fsSystemFanPad1Speed1 Integer32,
|
|
fsSystemFanPad1Speed2 Integer32,
|
|
fsSystemFanPad1Speed3 Integer32,
|
|
fsSystemFanPad1Speed4 Integer32,
|
|
fsSystemFanPad1Speed5 Integer32,
|
|
fsSystemFanPad1Speed6 Integer32,
|
|
fsSystemFanPad1Speed7 Integer32,
|
|
fsSystemFanPad1Speed8 Integer32,
|
|
fsSystemFanPad1Speed9 Integer32
|
|
}
|
|
|
|
fsSystemOamFanPad1Index OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the index of the fan pad."
|
|
::= { fsSystemFanPad1SpeedEntry 1 }
|
|
|
|
fsSystemOamFanPad1Name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the name of the fan pad."
|
|
::= { fsSystemFanPad1SpeedEntry 2 }
|
|
|
|
fsSystemFanPad1Speed1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the speed of the fan1."
|
|
::= { fsSystemFanPad1SpeedEntry 3 }
|
|
|
|
fsSystemFanPad1Speed2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the speed of the fan2."
|
|
::= { fsSystemFanPad1SpeedEntry 4 }
|
|
|
|
fsSystemFanPad1Speed3 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the speed of the fan3."
|
|
::= { fsSystemFanPad1SpeedEntry 5 }
|
|
|
|
fsSystemFanPad1Speed4 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the speed of the fan4."
|
|
::= { fsSystemFanPad1SpeedEntry 6 }
|
|
|
|
fsSystemFanPad1Speed5 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the speed of the fan5."
|
|
::= { fsSystemFanPad1SpeedEntry 7 }
|
|
|
|
fsSystemFanPad1Speed6 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the speed of the fan6."
|
|
::= { fsSystemFanPad1SpeedEntry 8 }
|
|
|
|
fsSystemFanPad1Speed7 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the speed of the fan7."
|
|
::= { fsSystemFanPad1SpeedEntry 9 }
|
|
|
|
fsSystemFanPad1Speed8 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the speed of the fan8."
|
|
::= { fsSystemFanPad1SpeedEntry 10 }
|
|
|
|
fsSystemFanPad1Speed9 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the speed of the fan9."
|
|
::= { fsSystemFanPad1SpeedEntry 11 }
|
|
|
|
fsSystemFanPad2SpeedTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemFanPad2SpeedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of fan's speed on fan pad2."
|
|
::= { fsSystemMIBObjects 56 }
|
|
|
|
fsSystemFanPad2SpeedEntry OBJECT-TYPE
|
|
SYNTAX FSSystemFanPad2SpeedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays fan's speed on same fan pad2"
|
|
INDEX { fsSystemOamFanPad2Index }
|
|
::= { fsSystemFanPad2SpeedTable 1 }
|
|
|
|
FSSystemFanPad2SpeedEntry ::=
|
|
SEQUENCE {
|
|
fsSystemOamFanPad2Index Integer32,
|
|
fsSystemOamFanPad2Name DisplayString,
|
|
fsSystemFanPad2Speed1 Integer32,
|
|
fsSystemFanPad2Speed2 Integer32,
|
|
fsSystemFanPad2Speed3 Integer32
|
|
}
|
|
|
|
fsSystemOamFanPad2Index OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the index of the fan pad2."
|
|
::= { fsSystemFanPad2SpeedEntry 1 }
|
|
|
|
fsSystemOamFanPad2Name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the name of the fan pad."
|
|
::= { fsSystemFanPad2SpeedEntry 2 }
|
|
|
|
fsSystemFanPad2Speed1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the speed of the fan1."
|
|
::= { fsSystemFanPad2SpeedEntry 3 }
|
|
|
|
fsSystemFanPad2Speed2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the speed of the fan2."
|
|
::= { fsSystemFanPad2SpeedEntry 4 }
|
|
|
|
fsSystemFanPad2Speed3 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the speed of the fan3."
|
|
::= { fsSystemFanPad2SpeedEntry 5 }
|
|
|
|
fsSystemFanPad3SpeedTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FSSystemFanPad3SpeedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of fan's speed on fan pad3."
|
|
::= { fsSystemMIBObjects 57 }
|
|
|
|
fsSystemFanPad3SpeedEntry OBJECT-TYPE
|
|
SYNTAX FSSystemFanPad3SpeedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry displays fan's speed on same fan pad3"
|
|
INDEX { fsSystemOamFanPad3Index }
|
|
::= { fsSystemFanPad3SpeedTable 1 }
|
|
|
|
FSSystemFanPad3SpeedEntry ::=
|
|
SEQUENCE {
|
|
fsSystemOamFanPad3Index Integer32,
|
|
fsSystemOamFanPad3Name DisplayString,
|
|
fsSystemFanPad3Speed1 Integer32,
|
|
fsSystemFanPad3Speed2 Integer32,
|
|
fsSystemFanPad3Speed3 Integer32,
|
|
fsSystemFanPad3Speed4 Integer32,
|
|
fsSystemFanPad3Speed5 Integer32
|
|
}
|
|
|
|
fsSystemOamFanPad3Index OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the index of the fan pad3."
|
|
::= { fsSystemFanPad3SpeedEntry 1 }
|
|
|
|
fsSystemOamFanPad3Name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the name of the fan pad."
|
|
::= { fsSystemFanPad3SpeedEntry 2 }
|
|
|
|
fsSystemFanPad3Speed1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the speed of the fan1."
|
|
::= { fsSystemFanPad3SpeedEntry 3 }
|
|
|
|
fsSystemFanPad3Speed2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the speed of the fan2."
|
|
::= { fsSystemFanPad3SpeedEntry 4 }
|
|
|
|
fsSystemFanPad3Speed3 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the speed of the fan3."
|
|
::= { fsSystemFanPad3SpeedEntry 5 }
|
|
|
|
fsSystemFanPad3Speed4 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the speed of the fan4."
|
|
::= { fsSystemFanPad3SpeedEntry 6 }
|
|
|
|
fsSystemFanPad3Speed5 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Return the speed of the fan5."
|
|
::= { fsSystemFanPad3SpeedEntry 7 }
|
|
|
|
fsSystemParamSaveErrIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Param Save Err Idx."
|
|
::= { fsSystemMIBObjects 58 }
|
|
|
|
fsSystemParamSaveErrMsg OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Param Save Err Msg."
|
|
::= { fsSystemMIBObjects 59 }
|
|
|
|
fsSystemMIBTraps OBJECT IDENTIFIER ::= { fsSystemMIB 2 }
|
|
|
|
fsSystemHardChangeDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The description of hard change"
|
|
::= { fsSystemMIBTraps 1 }
|
|
|
|
fsSystemHardChangeDetected NOTIFICATION-TYPE
|
|
OBJECTS {fsSystemHardChangeDesc}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System hardware has changed include number of devices or number of modules
|
|
or the place or type of the module is change."
|
|
::= { fsSystemMIBTraps 2 }
|
|
|
|
fsSystemPowerStateChange NOTIFICATION-TYPE
|
|
OBJECTS {fsSystemHwPower}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"while the state of power changed, then this trap will be sent."
|
|
::= { fsSystemMIBTraps 3 }
|
|
|
|
fsSystemFanStateChange NOTIFICATION-TYPE
|
|
OBJECTS {fsSystemHwFan}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"while the state of fan changed, then this trap will be sent."
|
|
::= { fsSystemMIBTraps 4 }
|
|
|
|
--2010-05
|
|
fsSystemCPUusageTooHighTrap NOTIFICATION-TYPE
|
|
OBJECTS {fsCPUUtilization1Min}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CPU usage Too High warning."
|
|
::= { fsSystemMIBTraps 5 }
|
|
|
|
--2010-05
|
|
fsSystemCPUusageTooHighRecovTrap NOTIFICATION-TYPE
|
|
OBJECTS {fsCPUUtilization1Min}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"clear the warning of CPU usage too high and report the current CPU usage."
|
|
::= { fsSystemMIBTraps 6 }
|
|
|
|
--2010-05
|
|
fsSystemTmpTooHighTrap NOTIFICATION-TYPE
|
|
OBJECTS {fsSystemTemperatureCurrent}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature Too High warning."
|
|
::= { fsSystemMIBTraps 7 }
|
|
|
|
--Temperature Too High Recover Trap 2010-05
|
|
fsSystemTmpTooHighRecovTrap NOTIFICATION-TYPE
|
|
OBJECTS {fsSystemTemperatureCurrent}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"clear the warning of temperature too high and report the current temperature."
|
|
::= { fsSystemMIBTraps 8 }
|
|
|
|
--Memory usage too high trap 2010-05
|
|
fsSystemMemusageTooHighTrap NOTIFICATION-TYPE
|
|
OBJECTS {fsMemoryPoolCurrentUtilization}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Memory usage too high warning."
|
|
::= { fsSystemMIBTraps 9 }
|
|
|
|
--Memory usage too high recover trap 2010-05
|
|
fsSystemMemusageTooHighRecovTrap NOTIFICATION-TYPE
|
|
OBJECTS {fsMemoryPoolCurrentUtilization}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"clear the warning of Memory usage too high and report the current Memory usage."
|
|
::= { fsSystemMIBTraps 10 }
|
|
|
|
--lank ap 2010-7
|
|
fsSystemLankApCPUusageTooHighTrap NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsApMacAddr,
|
|
fsCPUUtilization1Min
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"lank ap CPU usage Too High warning."
|
|
::= { fsSystemMIBTraps 11 }
|
|
|
|
--lank ap 2010-7
|
|
fsSystemLankApCPUusageTooHighRecovTrap NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsApMacAddr,
|
|
fsCPUUtilization1Min
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"clear the warning of lank ap CPU usage too high and report the current CPU usage."
|
|
::= { fsSystemMIBTraps 12 }
|
|
|
|
--lank ap 2010-7
|
|
fsSystemLankApMemusageTooHighTrap NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsApMacAddr,
|
|
fsMemoryPoolCurrentUtilization
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"lank ap Memory usage too high warning."
|
|
::= { fsSystemMIBTraps 13 }
|
|
|
|
--lank ap 2010-7
|
|
fsSystemLankApMemusageTooHighRecovTrap NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsApMacAddr,
|
|
fsMemoryPoolCurrentUtilization
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"clear the warning of lank ap Memory usage too high and report the current Memory usage."
|
|
::= { fsSystemMIBTraps 14 }
|
|
|
|
--System reset trap 2010-7
|
|
fsSystemResetTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"send a trap while system reset"
|
|
::= { fsSystemMIBTraps 15 }
|
|
|
|
--lank ap reset trap 2010-8
|
|
fsSystemLankApResetTrap NOTIFICATION-TYPE
|
|
OBJECTS {fsApMacAddr}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"send a trap while lank ap system reset"
|
|
::= { fsSystemMIBTraps 16 }
|
|
|
|
fsSystemPowerOnTrap NOTIFICATION-TYPE
|
|
OBJECTS {fsSystemPowerIndex}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"send a trap while power on."
|
|
::= { fsSystemMIBTraps 17 }
|
|
|
|
fsSystemPowerOffTrap NOTIFICATION-TYPE
|
|
OBJECTS {fsSystemPowerIndex}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"send a trap while power off."
|
|
::= { fsSystemMIBTraps 18 }
|
|
|
|
fsSystemPowerOnTrapInVSU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsSystemSwitchID,
|
|
fsSystemPowerIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"send a trap while power on in VSU."
|
|
::= { fsSystemMIBTraps 19 }
|
|
|
|
fsSystemPowerOffTrapInVSU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsSystemSwitchID,
|
|
fsSystemPowerIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"send a trap while power off in VSU."
|
|
::= { fsSystemMIBTraps 20 }
|
|
|
|
fsSystemTmpTableTooHighTrap NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsSystemMultipleTemperatureSlotIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature Too High warning with the slot index."
|
|
::= { fsSystemMIBTraps 21 }
|
|
|
|
fsSystemTmpTableTooHighRecovTrap NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsSystemMultipleTemperatureSlotIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"clear the warning of Temperature too high with the slot index."
|
|
::= { fsSystemMIBTraps 22 }
|
|
|
|
fsSystemTmpTableTooHighTrapVSU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsSystemMultipleTemperatureDeviceIndex,
|
|
fsSystemMultipleTemperatureSlotIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature Too High warning with the slot index in VSU."
|
|
::= { fsSystemMIBTraps 23 }
|
|
|
|
fsSystemTmpTableTooHighRecovTrapVSU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsSystemMultipleTemperatureDeviceIndex,
|
|
fsSystemMultipleTemperatureSlotIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"clear the warning of Temperature too high with the slot index."
|
|
::= { fsSystemMIBTraps 24 }
|
|
|
|
fsSystemFanTableStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsSystemFanStatusFanIndex,
|
|
fsSystemFanStatusIndex,
|
|
fsSystemFanStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"while the state of fan changed, then this trap will be sent."
|
|
::= { fsSystemMIBTraps 25 }
|
|
|
|
fsSystemFanTableStateChangeVSU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsSystemFanStatusDeviceIndex,
|
|
fsSystemFanStatusFanIndex,
|
|
fsSystemFanStatusIndex,
|
|
fsSystemFanStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In VSU, while the state of fan changed, then this trap will be sent."
|
|
::= { fsSystemMIBTraps 26 }
|
|
|
|
fsSystemParamSaveErr NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsSystemParamSaveErrIdx,
|
|
fsSystemParamSaveErrMsg
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"while call exec write, then this trap will be sent."
|
|
::= { fsSystemMIBTraps 27 }
|
|
|
|
fsSystemFanTableOn NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsSystemFanStatusFanIndex,
|
|
fsSystemFanStatusIndex,
|
|
fsSystemFanStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"while fan is turned on, then this trap will be sent."
|
|
::= { fsSystemMIBTraps 28 }
|
|
|
|
fsSystemFanTableOff NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsSystemFanStatusFanIndex,
|
|
fsSystemFanStatusIndex,
|
|
fsSystemFanStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"while fan is turned off, then this trap will be sent."
|
|
::= { fsSystemMIBTraps 29 }
|
|
|
|
fsSystemFanTableOnVSU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsSystemFanStatusDeviceIndex,
|
|
fsSystemFanStatusFanIndex,
|
|
fsSystemFanStatusIndex,
|
|
fsSystemFanStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In VSU, while fan is turned on, then this trap will be sent."
|
|
::= { fsSystemMIBTraps 30 }
|
|
|
|
fsSystemFanTableOffVSU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
fsSystemFanStatusDeviceIndex,
|
|
fsSystemFanStatusFanIndex,
|
|
fsSystemFanStatusIndex,
|
|
fsSystemFanStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In VSU, while fan is turned off, then this trap will be sent."
|
|
::= { fsSystemMIBTraps 31 }
|
|
fsSystemMIBConformance OBJECT IDENTIFIER ::= { fsSystemMIB 3 }
|
|
fsSystemMIBCompliances OBJECT IDENTIFIER ::= { fsSystemMIBConformance 1 }
|
|
fsSystemMIBGroups OBJECT IDENTIFIER ::= { fsSystemMIBConformance 2 }
|
|
|
|
|
|
-- compliance statements
|
|
|
|
fsSystemMIBCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
the FS System MIB"
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { fsSystemMIBGroup
|
|
}
|
|
::= { fsSystemMIBCompliances 1 }
|
|
|
|
-- units of conformance
|
|
|
|
fsSystemMIBGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
fsSystemHwVersion,
|
|
fsSystemSwVersion,
|
|
fsSystemBootVersion,
|
|
fsSystemSysCtrlVersion,
|
|
fsSystemParametersSave,
|
|
fsSystemReset,
|
|
fsSystemOutBandRate,
|
|
fsSwitchLayer
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing system information and
|
|
opertion to a FS agent."
|
|
::= { fsSystemMIBGroups 1 }
|
|
|
|