Files
librenms-librenms/mibs/telco-systems/binox/PRVT-SYS-MON-MIB
Tony Murray 11147d3bbf Major Processors rewrite (#8066)
* Extract DiscoveryItem and move some things to better places.
Extract model class
Fix up model construction.  I have problem with construction...
Makeshift model working.  Switch constructor to factory.  discover() and create()
Support legacy discovery.
Remove uneeded custom pollers
Remove netonix custom detection as we try ucd on all os now.
Add a few yaml procs.  Fix a couple things.
More processor discovery conversions
Move Calix e7 to standard hrProcessorLoad, but it doesn't fully implement the HR-MIB, move things around to make it work.
Add a few yaml procs.  Fix a couple things. Correct some stupid mib stuff.
Move more, drop php 5.3
Add netscaler which uses string indexes.  Port fiberhome to yaml and use skip_values
More conversions.  BroadcomProcessorUsage Trait
Serveriron and Ironware share some mibs.  Create a common abstract os for them.
Add yaml support for mib specification in each data entry
Make legacy discover_processor() set 0 for hrDeviceIndex

Untangle Dell switch OS processors

Use use shared OS for groups if they don't have a specific group.
fix silly mib mistake

Make index optional

Move HR and UCD to Traits and out of Processor.

* forgot to update the fortiswitch index

* Make sgos and avaya-ers match the old index.

* fix comware test data

* fix merge errors

* fix dsm and remove pointless empty modules

* file not found exception is in the wrong place.

* Updated processor development docs
2018-02-05 07:39:13 -06:00

719 lines
20 KiB
Plaintext

-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-SYS-MON-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
PRVT-SYS-MON-MIB DEFINITIONS ::= BEGIN
IMPORTS
software
FROM PRVT-SWITCH-MIB
Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE,
Unsigned32
FROM SNMPv2-SMI
TruthValue
FROM SNMPv2-TC;
prvtSysMonMIB MODULE-IDENTITY
LAST-UPDATED "201312120000Z"
ORGANIZATION
"BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"Information for system resources"
REVISION "201312120000Z"
DESCRIPTION
"add prvtSysMonDoorOpen table prvtSysMonDoorOpenTest notification."
REVISION "200909040000Z"
DESCRIPTION
"Sync to internal implementation."
::= { software 3 }
prvtSysMonNotifications OBJECT IDENTIFIER
::= { prvtSysMonMIB 0 }
prvtSysMonObjects OBJECT IDENTIFIER
::= { prvtSysMonMIB 1 }
prvtSysMonCurrentCpuUsage OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current CPU Utilization"
::= { prvtSysMonObjects 1 }
prvtSysMonCurrentCpuTemperature OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current CPU Temperature"
::= { prvtSysMonObjects 2 }
prvtSysMonCurrentRamUsage OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current RAM Utilization"
::= { prvtSysMonObjects 3 }
prvtSysMonSelfTestExecuteNow OBJECT-TYPE
SYNTAX Integer32 (0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is set to '1', command
self-test execute-now. Setting the variable to '0'
results in an 'inconsistentValue' error.
Setting it to any other value has no effect.
When this object is read, the value '0' is returned."
::= { prvtSysMonObjects 4 }
prvtSysMonCpuUsage OBJECT IDENTIFIER
::= { prvtSysMonObjects 5 }
prvtSysMonCpuUsageShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shutdown cpu usage test"
::= { prvtSysMonCpuUsage 1 }
prvtSysMonCpuUsageLog OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send log if test failed"
::= { prvtSysMonCpuUsage 2 }
prvtSysMonCpuUsageLed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable led if test failed"
::= { prvtSysMonCpuUsage 3 }
prvtSysMonCpuUsageTrap OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send trap if test failed"
::= { prvtSysMonCpuUsage 4 }
prvtSysMonCpuUsagePeriod OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Test period in seconds"
::= { prvtSysMonCpuUsage 5 }
prvtSysMonCpuUsageLowThreshold OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low threshold"
::= { prvtSysMonCpuUsage 6 }
prvtSysMonCpuUsageHighThreshold OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High threshold"
::= { prvtSysMonCpuUsage 7 }
prvtSysMonCpuUsageLastStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { prvtSysMonCpuUsage 8 }
prvtSysMonCPUTemperature OBJECT IDENTIFIER
::= { prvtSysMonObjects 6 }
prvtSysMonCpuTemperatureShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shutdown cpu usage test"
::= { prvtSysMonCPUTemperature 1 }
prvtSysMonCpuTemperatureLog OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send log if test failed"
::= { prvtSysMonCPUTemperature 2 }
prvtSysMonCpuTemperatureLed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable led if test failed"
::= { prvtSysMonCPUTemperature 3 }
prvtSysMonCpuTemperatureTrap OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send trap if test failed"
::= { prvtSysMonCPUTemperature 4 }
prvtSysMonCpuTemperaturePeriod OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Test period in seconds"
::= { prvtSysMonCPUTemperature 5 }
prvtSysMonCpuTemperatureLowThreshold OBJECT-TYPE
SYNTAX Integer32 (-40..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low threshold"
::= { prvtSysMonCPUTemperature 6 }
prvtSysMonCpuTemperatureHighThreshold OBJECT-TYPE
SYNTAX Integer32 (-40..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High threshold"
::= { prvtSysMonCPUTemperature 7 }
prvtSysMonCpuTemperatureLastStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { prvtSysMonCPUTemperature 8 }
prvtSysMonRAMUsage OBJECT IDENTIFIER
::= { prvtSysMonObjects 7 }
prvtSysMonRamUsageShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shutdown cpu usage test"
::= { prvtSysMonRAMUsage 1 }
prvtSysMonRamUsageLog OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send log if test failed"
::= { prvtSysMonRAMUsage 2 }
prvtSysMonRamUsageLed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable led if test failed"
::= { prvtSysMonRAMUsage 3 }
prvtSysMonRamUsageTrap OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send trap if test failed"
::= { prvtSysMonRAMUsage 4 }
prvtSysMonRamUsagePeriod OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Test period in seconds"
::= { prvtSysMonRAMUsage 5 }
prvtSysMonRamUsageLowThreshold OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low threshold"
::= { prvtSysMonRAMUsage 6 }
prvtSysMonRamUsageHighThreshold OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High threshold"
::= { prvtSysMonRAMUsage 7 }
prvtSysMonRamUsageLastStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { prvtSysMonRAMUsage 8 }
prvtSysMonPortStatistics OBJECT IDENTIFIER
::= { prvtSysMonObjects 8 }
prvtSysMonPortStatisticsShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shutdown cpu usage test"
::= { prvtSysMonPortStatistics 1 }
prvtSysMonPortStatisticsLog OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send log if test failed"
::= { prvtSysMonPortStatistics 2 }
prvtSysMonPortStatisticsLed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable led if test failed"
::= { prvtSysMonPortStatistics 3 }
prvtSysMonPortStatisticsTrap OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send trap if test failed"
::= { prvtSysMonPortStatistics 4 }
prvtSysMonPortStatisticsPeriod OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Test period in seconds"
::= { prvtSysMonPortStatistics 5 }
prvtSysMonPortStatisticsLowThreshold OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low threshold"
::= { prvtSysMonPortStatistics 6 }
prvtSysMonPortStatisticsHighThreshold OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High threshold"
::= { prvtSysMonPortStatistics 7 }
prvtSysMonPortStatisticsLastStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { prvtSysMonPortStatistics 8 }
prvtSysMonPortStatisticsLastFailedPorts OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { prvtSysMonPortStatistics 9 }
prvtSysMonFan OBJECT IDENTIFIER
::= { prvtSysMonObjects 9 }
prvtSysMonFanShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shutdown cpu usage test"
::= { prvtSysMonFan 1 }
prvtSysMonFanLog OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send log if test failed"
::= { prvtSysMonFan 2 }
prvtSysMonFanLed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable led if test failed"
::= { prvtSysMonFan 3 }
prvtSysMonFanTrap OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send trap if test failed"
::= { prvtSysMonFan 4 }
prvtSysMonFanPeriod OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Test period in seconds"
::= { prvtSysMonFan 5 }
prvtSysMonFanLastStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { prvtSysMonFan 6 }
prvtSysMonOnboardPower OBJECT IDENTIFIER
::= { prvtSysMonObjects 10 }
prvtSysMonOnboardPowerShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shutdown cpu usage test"
::= { prvtSysMonOnboardPower 1 }
prvtSysMonOnboardPowerLog OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send log if test failed"
::= { prvtSysMonOnboardPower 2 }
prvtSysMonOnboardPowerLed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable led if test failed"
::= { prvtSysMonOnboardPower 3 }
prvtSysMonOnboardPowerTrap OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send trap if test failed"
::= { prvtSysMonOnboardPower 4 }
prvtSysMonOnboardPowerPeriod OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Test period in seconds"
::= { prvtSysMonOnboardPower 5 }
prvtSysMonOnboardPowerLastStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { prvtSysMonOnboardPower 6 }
prvtSysMonPowerSupply OBJECT IDENTIFIER
::= { prvtSysMonObjects 11 }
prvtSysMonPowerSupplyShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shutdown cpu usage test"
::= { prvtSysMonPowerSupply 1 }
prvtSysMonPowerSupplyLog OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send log if test failed"
::= { prvtSysMonPowerSupply 2 }
prvtSysMonPowerSupplyLed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable led if test failed"
::= { prvtSysMonPowerSupply 3 }
prvtSysMonPowerSupplyTrap OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send trap if test failed"
::= { prvtSysMonPowerSupply 4 }
prvtSysMonPowerSupplyPeriod OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Test period in seconds"
::= { prvtSysMonPowerSupply 5 }
prvtSysMonPowerSupplyLastStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { prvtSysMonPowerSupply 6 }
prvtSysMonPowerSupplyFan OBJECT IDENTIFIER
::= { prvtSysMonObjects 12 }
prvtSysMonPowerSupplyFanShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shutdown cpu usage test"
::= { prvtSysMonPowerSupplyFan 1 }
prvtSysMonPowerSupplyFanLog OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send log if test failed"
::= { prvtSysMonPowerSupplyFan 2 }
prvtSysMonPowerSupplyFanLed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable led if test failed"
::= { prvtSysMonPowerSupplyFan 3 }
prvtSysMonPowerSupplyFanTrap OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send trap if test failed"
::= { prvtSysMonPowerSupplyFan 4 }
prvtSysMonPowerSupplyFanPeriod OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Test period in seconds"
::= { prvtSysMonPowerSupplyFan 5 }
prvtSysMonPowerSupplyFanLastStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { prvtSysMonPowerSupplyFan 6 }
prvtSysMonDoorOpen OBJECT IDENTIFIER
::= { prvtSysMonObjects 13 }
prvtSysMonDoorOpenShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shutdown cpu usage test"
::= { prvtSysMonDoorOpen 1 }
prvtSysMonDoorOpenLog OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send log if test failed"
::= { prvtSysMonDoorOpen 2 }
prvtSysMonDoorOpenLed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable led if test failed"
::= { prvtSysMonDoorOpen 3 }
prvtSysMonDoorOpenTrap OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Send trap if test failed"
::= { prvtSysMonDoorOpen 4 }
prvtSysMonDoorOpenPeriod OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Test period in seconds"
::= { prvtSysMonDoorOpen 5 }
prvtSysMonDoorOpenLastStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { prvtSysMonDoorOpen 6 }
prvtSysMonCpuUtilization NOTIFICATION-TYPE
OBJECTS { prvtSysMonCurrentCpuUsage,
prvtSysMonCpuUsageLowThreshold,
prvtSysMonCpuUsageHighThreshold }
STATUS current
DESCRIPTION
"CPU utilization test has passed the
program threshold."
::= { prvtSysMonNotifications 1 }
prvtSysMonRamUsage NOTIFICATION-TYPE
OBJECTS { prvtSysMonCurrentRamUsage,
prvtSysMonRamUsageLowThreshold,
prvtSysMonRamUsageHighThreshold }
STATUS current
DESCRIPTION
"Memory utilization test has passed the
program threshold."
::= { prvtSysMonNotifications 2 }
prvtSysMonPowerSupplyTest NOTIFICATION-TYPE
OBJECTS { prvtSysMonPowerSupplyLastStatus }
STATUS current
DESCRIPTION
"Result from power supply test has changed."
::= { prvtSysMonNotifications 3 }
prvtSysMonFansTest NOTIFICATION-TYPE
OBJECTS { prvtSysMonFanLastStatus }
STATUS current
DESCRIPTION
"Result from fan test has changed."
::= { prvtSysMonNotifications 4 }
prvtSysMonCpuTemperature NOTIFICATION-TYPE
OBJECTS { prvtSysMonCurrentCpuTemperature,
prvtSysMonCpuTemperatureLowThreshold,
prvtSysMonCpuTemperatureHighThreshold }
STATUS current
DESCRIPTION
"CPU temperature test has passed the
program threshold."
::= { prvtSysMonNotifications 5 }
prvtSysMonPortStatisticsTest NOTIFICATION-TYPE
OBJECTS { prvtSysMonPortStatisticsLastFailedPorts }
STATUS current
DESCRIPTION
"Result from port statistics test has changed."
::= { prvtSysMonNotifications 6 }
prvtSysMonPowerSupplyFansTest NOTIFICATION-TYPE
OBJECTS { prvtSysMonPowerSupplyFanLastStatus }
STATUS current
DESCRIPTION
"Result from power-supply-fan test has changed."
::= { prvtSysMonNotifications 7 }
prvtSysMonOnBoardPowerSupplyTest NOTIFICATION-TYPE
OBJECTS { prvtSysMonOnboardPowerLastStatus }
STATUS current
DESCRIPTION
"Result from onboard-power test has changed."
::= { prvtSysMonNotifications 8 }
prvtSysMonDoorOpenTest NOTIFICATION-TYPE
OBJECTS { prvtSysMonDoorOpenLastStatus }
STATUS current
DESCRIPTION
"Result from door-open test has changed."
::= { prvtSysMonNotifications 9 }
END -- end of module PRVT-SYS-MON-MIB.