Files
Tony Murray 11147d3bbf Major Processors rewrite (#8066)
* Extract DiscoveryItem and move some things to better places.
Extract model class
Fix up model construction.  I have problem with construction...
Makeshift model working.  Switch constructor to factory.  discover() and create()
Support legacy discovery.
Remove uneeded custom pollers
Remove netonix custom detection as we try ucd on all os now.
Add a few yaml procs.  Fix a couple things.
More processor discovery conversions
Move Calix e7 to standard hrProcessorLoad, but it doesn't fully implement the HR-MIB, move things around to make it work.
Add a few yaml procs.  Fix a couple things. Correct some stupid mib stuff.
Move more, drop php 5.3
Add netscaler which uses string indexes.  Port fiberhome to yaml and use skip_values
More conversions.  BroadcomProcessorUsage Trait
Serveriron and Ironware share some mibs.  Create a common abstract os for them.
Add yaml support for mib specification in each data entry
Make legacy discover_processor() set 0 for hrDeviceIndex

Untangle Dell switch OS processors

Use use shared OS for groups if they don't have a specific group.
fix silly mib mistake

Make index optional

Move HR and UCD to Traits and out of Processor.

* forgot to update the fortiswitch index

* Make sgos and avaya-ers match the old index.

* fix comware test data

* fix merge errors

* fix dsm and remove pointless empty modules

* file not found exception is in the wrong place.

* Updated processor development docs
2018-02-05 07:39:13 -06:00

221 lines
6.2 KiB
Plaintext

-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: priv_lsl.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
--
PRIV-LSL-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP
FROM SNMPv2-CONF
TEXTUAL-CONVENTION,
MacAddress
FROM SNMPv2-TC
ifIndex
FROM IF-MIB
switch
FROM PRVT-SWITCH-MIB;
privLsl MODULE-IDENTITY
LAST-UPDATED "200803210000Z"
ORGANIZATION "BATM Advanced Communication"
CONTACT-INFO
" BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"MIB module for management of Logical Service Loopback(LSL) Iometrix compatible product."
REVISION "200803210000Z"
DESCRIPTION
"Initial"
::= { switch 113 }
privLslLevel1 OBJECT IDENTIFIER ::= { privLsl 1 } -- all tables and scalars for Lsl level 1
privLslObjects OBJECT IDENTIFIER ::= { privLslLevel1 1 } -- tables and scalars
privLslNotifications OBJECT IDENTIFIER ::= { privLslLevel1 2 } -- traps according to rfc2580.txt SMIv2-CONF
privLslConformance OBJECT IDENTIFIER ::= { privLslLevel1 3 } -- conformance according to rfc2580.txt SMIv2-CONF
-- Textual Conventions
PrivLslStates ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "The the switch on/off states for LSL on ports."
SYNTAX INTEGER {
enable(1),
disable(2)
}
-- Object definitiosn in privLslObjects
privLslGlobalMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the destination mac address assigned
to lsl packets. The device can recognise the lsl packets
by a specific destination mac address given by this
object.
"
::= { privLslObjects 1 }
privLslManagementTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrivLslManagementEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"LSL interface extention table.
This table contains all objects which are used for LSL
management per interface. It uses ifIndex defined in
rfc1213"
::= { privLslObjects 2 }
privLslManagementEntry OBJECT-TYPE
SYNTAX PrivLslManagementEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The only valid LSL interfaces are phyical port interfaces"
INDEX { ifIndex }
::= { privLslManagementTable 1 }
PrivLslManagementEntry ::= SEQUENCE {
privLslStatus PrivLslStates
}
privLslStatus OBJECT-TYPE
SYNTAX PrivLslStates
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the port have Logical Service
Loopback enabled or disabled. It allows the client to
determine which interface should be used for this type
of service"
::= { privLslManagementEntry 1 }
privIometrixManagementTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrivIometrixManagementEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Iometrix Level 1 table.
This table contains all objects which are used for Iometrix
level 1 management per interface. It uses ifIndex defined in
rfc1213"
::= { privLslObjects 3 }
privIometrixManagementEntry OBJECT-TYPE
SYNTAX PrivIometrixManagementEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"the index is ifindex"
INDEX { ifIndex }
::= { privIometrixManagementTable 1 }
PrivIometrixManagementEntry ::= SEQUENCE {
privIometrixStatus PrivLslStates
}
privIometrixStatus OBJECT-TYPE
SYNTAX PrivLslStates
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the port have Logical Service
Loopback enabled or disabled. It allows the client to
determine which interface should be used for this type
of service"
::= { privIometrixManagementEntry 1 }
-- Notification NOTIFICATION-TYPE definitions in privLslNotifications
-- according to rfc2580.txt SMIv2-CONF
-- (Currently no notifications)
-- Conformance Information
privLslGroups OBJECT IDENTIFIER ::= { privLslConformance 1 }
privLslCompliances OBJECT IDENTIFIER ::= { privLslConformance 2 }
privLevel1ObjectsGroup OBJECT-GROUP
OBJECTS { privLslGlobalMacAddress, privLslStatus, privIometrixStatus }
STATUS current
DESCRIPTION
"All objects related to level1 logical loopback service. Object
grouping will be extended if the mib is also extended"
::= { privLslGroups 1 }
privLevel1Compliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement. It will be extended if new
functionality is added"
MODULE -- this module
MANDATORY-GROUPS { privLevel1ObjectsGroup }
OBJECT privLslGlobalMacAddress
MIN-ACCESS read-only
DESCRIPTION
"read-write access "
OBJECT privLslStatus
MIN-ACCESS read-only
DESCRIPTION
"read-write access "
OBJECT privIometrixStatus
MIN-ACCESS read-only
DESCRIPTION
"read-write access "
::= { privLslCompliances 1 }
END