* Extract DiscoveryItem and move some things to better places. Extract model class Fix up model construction. I have problem with construction... Makeshift model working. Switch constructor to factory. discover() and create() Support legacy discovery. Remove uneeded custom pollers Remove netonix custom detection as we try ucd on all os now. Add a few yaml procs. Fix a couple things. More processor discovery conversions Move Calix e7 to standard hrProcessorLoad, but it doesn't fully implement the HR-MIB, move things around to make it work. Add a few yaml procs. Fix a couple things. Correct some stupid mib stuff. Move more, drop php 5.3 Add netscaler which uses string indexes. Port fiberhome to yaml and use skip_values More conversions. BroadcomProcessorUsage Trait Serveriron and Ironware share some mibs. Create a common abstract os for them. Add yaml support for mib specification in each data entry Make legacy discover_processor() set 0 for hrDeviceIndex Untangle Dell switch OS processors Use use shared OS for groups if they don't have a specific group. fix silly mib mistake Make index optional Move HR and UCD to Traits and out of Processor. * forgot to update the fortiswitch index * Make sgos and avaya-ers match the old index. * fix comware test data * fix merge errors * fix dsm and remove pointless empty modules * file not found exception is in the wrong place. * Updated processor development docs
1383 lines
33 KiB
Plaintext
1383 lines
33 KiB
Plaintext
-- *********************************************************************
|
||
-- *********************************************************************
|
||
-- ** Filename: PRVT-CES-MIB.mib
|
||
-- ** Project: T - Ethernet and Fast Ethernet IP Switches.
|
||
-- ** Purpose: Private MIB
|
||
-- *********************************************************************
|
||
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
|
||
-- WARNING:
|
||
--
|
||
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
|
||
--
|
||
-- This file is the property of BATM Advanced Communications.
|
||
-- BATM Advanced Communications retains all title and
|
||
-- ownership in the Specification, including any revisions.
|
||
|
||
-- BATM Advanced Communications grants all interested parties a non-exclusive
|
||
-- license to use and distribute an unmodified copy of this
|
||
-- Specification in connection with management of BATM Advanced Communications
|
||
-- and Telco Systems products, and without fee, provided that the following
|
||
-- conditions are met:
|
||
-- 1. Redistributions of this specification must retain the above copyright
|
||
-- notice, this list of conditions and the following disclaimer.
|
||
-- 2. Redistributions in binary form must reproduce the above copyright
|
||
-- notice, this list of conditions and the following disclaimer in the
|
||
-- documentation and/or other materials provided with the distribution.
|
||
-- 3. The name of the BATM Advanced Communications MAY NOT be used to endorse
|
||
-- or promote products derived from this specification without specific prior written
|
||
-- permission.
|
||
--
|
||
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
|
||
-- WARRANTY, THE SPECIFICATIONS CONTAINED IN THIS FILE ARE
|
||
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
|
||
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
|
||
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
|
||
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
|
||
-- INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
|
||
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
|
||
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
|
||
-- TO USE, THE SPECIFICATION CONTAINED IN THIS FILE.
|
||
PRVT-CES-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
MODULE-IDENTITY,
|
||
OBJECT-TYPE,
|
||
IpAddress,
|
||
Gauge32,
|
||
Integer32,
|
||
Unsigned32,
|
||
NOTIFICATION-TYPE
|
||
FROM SNMPv2-SMI
|
||
|
||
TimeStamp
|
||
FROM SNMPv2-TC
|
||
|
||
dsx1ConfigEntry
|
||
FROM DS1-MIB
|
||
|
||
TEXTUAL-CONVENTION
|
||
FROM SNMPv2-TC
|
||
|
||
MODULE-COMPLIANCE, NOTIFICATION-GROUP,
|
||
OBJECT-GROUP
|
||
FROM SNMPv2-CONF
|
||
|
||
switch
|
||
FROM PRVT-SWITCH-MIB;
|
||
|
||
prvtCESMib MODULE-IDENTITY
|
||
LAST-UPDATED "200905180000Z"
|
||
ORGANIZATION "BATM Advanced Communication"
|
||
CONTACT-INFO
|
||
"BATM/Telco Systems Support team
|
||
Email:
|
||
For North America: techsupport@telco.com
|
||
For North Europe: support@batm.de, info@batm.de
|
||
For the rest of the world: techsupport@telco.com"
|
||
|
||
DESCRIPTION
|
||
"This module includes configuration parameters for DS1 modules not included in
|
||
DS1-MIB."
|
||
|
||
-- revision history
|
||
REVISION "200905180000Z"
|
||
DESCRIPTION
|
||
"OC3 Alarm Enhacements"
|
||
|
||
REVISION "200905140000Z"
|
||
DESCRIPTION
|
||
"Add prvtCESApsTable"
|
||
|
||
REVISION "200905050000Z"
|
||
DESCRIPTION
|
||
"Add prvtCESUpdateFirmwareTable"
|
||
|
||
REVISION "200903190000Z"
|
||
DESCRIPTION
|
||
"Add new objects prvtCESServiceClock, prvtCESModuleServiceClock"
|
||
|
||
REVISION "200902250000Z"
|
||
DESCRIPTION
|
||
"Add prvtCESCICTable, prvtCESCICMappTable,
|
||
prvtCESModulePolicyLopsEnter, prvtCESModulePolicyLopsExit "
|
||
REVISION "200902160000Z"
|
||
DESCRIPTION
|
||
"Modified values for objects
|
||
prvtCESModulePolicyLops, prvtCESModulePolicyRbit,
|
||
prvtCESModulePolicyRd"
|
||
REVISION "200806190000Z"
|
||
DESCRIPTION
|
||
"Added new objects
|
||
prvtCESClearPortStatistics, prvtCESModuleClearCircuitStatistics,
|
||
prvtCESModuleLbit, prvtCESModulePolicyLops,
|
||
prvtCESModulePolicyLbit, prvtCESModulePolicyRbit,
|
||
prvtCESModulePolicyRd, prvtCESModulePolicyIdlePattern,
|
||
prvtCESModulePolicyIdleSignalling"
|
||
|
||
REVISION "200603070000Z"
|
||
DESCRIPTION
|
||
"Added an additional port index to the alarm table."
|
||
|
||
REVISION "200602230000Z"
|
||
DESCRIPTION
|
||
"Added the TCA alarms table objects and the TCA alarm trap."
|
||
|
||
REVISION "200503110000Z"
|
||
DESCRIPTION
|
||
"Initial version."
|
||
|
||
::= { switch 111 }
|
||
|
||
--
|
||
-- Variable Type definitions
|
||
--
|
||
|
||
ConfigAction ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is used to specify what is to be done with unapplied CES module configuration."
|
||
SYNTAX INTEGER {
|
||
noop(1),
|
||
applyConfiguration(2),
|
||
rejectConfiguration(3),
|
||
restart(4)
|
||
}
|
||
|
||
E1Impedance ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is used to configure E1 line type termination impedance."
|
||
SYNTAX INTEGER {
|
||
notApplicable(0),
|
||
e1-75ohm(1),
|
||
e1-75hrl(2),
|
||
e1-120ohm(3),
|
||
e1-120hrl(4)
|
||
}
|
||
|
||
T1LongCableLength ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is used to configure T1 long cable length."
|
||
SYNTAX INTEGER {
|
||
notApplicable (1),
|
||
neg75dB (2),
|
||
neg15dB (3),
|
||
neg225dB (4),
|
||
zerodB (5)
|
||
}
|
||
|
||
T1GainLimit ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is used to configure T1 type Tx or Rx gain limit."
|
||
SYNTAX INTEGER {
|
||
notApplicable(0),
|
||
none(1),
|
||
gain30(2),
|
||
gain36(3)
|
||
}
|
||
|
||
CESLineType ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This value is used to configure the line mode common for all TDM ports of the module."
|
||
SYNTAX INTEGER {
|
||
e1(1),
|
||
t1(2),
|
||
e1-sdh(3),
|
||
t1-sdh(4),
|
||
t1-sonet(5)
|
||
}
|
||
|
||
ServiceClock ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This values are used to configure transmit clock as one of this modes."
|
||
SYNTAX INTEGER{
|
||
notAplicable(0),
|
||
loopTiming (1),
|
||
localTiming (2),
|
||
adaptive (3),
|
||
differntial (4)
|
||
}
|
||
|
||
prvtCESNotifications OBJECT IDENTIFIER ::= { prvtCESMib 0 }
|
||
prvtCESObjects OBJECT IDENTIFIER ::= { prvtCESMib 1 }
|
||
prvtCESConformance OBJECT IDENTIFIER ::= { prvtCESMib 2 }
|
||
|
||
--
|
||
-- ces objects
|
||
--
|
||
prvtCESDsx1ExtTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PrvtCESDsx1ExtEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This table contains object for configuring DS1 interfaces, not supported in dsx1ConfigTable."
|
||
::= { prvtCESObjects 1 }
|
||
|
||
prvtCESDsx1ExtEntry OBJECT-TYPE
|
||
SYNTAX PrvtCESDsx1ExtEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"prvtCESDsx1ExtEntry"
|
||
AUGMENTS { dsx1ConfigEntry }
|
||
::= { prvtCESDsx1ExtTable 1 }
|
||
|
||
PrvtCESDsx1ExtEntry ::= SEQUENCE {
|
||
prvtCESE1Impedance E1Impedance,
|
||
prvtCEST1GainLimit T1GainLimit,
|
||
prvtCESPortShutdown INTEGER,
|
||
prvtCESPortLineType INTEGER,
|
||
prvtCEST1LongCableLength T1LongCableLength,
|
||
prvtCESPortOperStatus INTEGER,
|
||
prvtCESClearPortStatistics INTEGER,
|
||
prvtCESServiceClock ServiceClock
|
||
}
|
||
|
||
prvtCESE1Impedance OBJECT-TYPE
|
||
SYNTAX E1Impedance
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object configures temination impedance for TDM ports if the line type is E1."
|
||
::= { prvtCESDsx1ExtEntry 1 }
|
||
|
||
prvtCEST1GainLimit OBJECT-TYPE
|
||
SYNTAX T1GainLimit
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object configures Tx or Rx gain limit for TDM ports if the line type is T1."
|
||
::= { prvtCESDsx1ExtEntry 2 }
|
||
|
||
prvtCESPortShutdown OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Shutdown TDM port."
|
||
::= { prvtCESDsx1ExtEntry 3 }
|
||
|
||
prvtCESPortLineType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
dsx1ESF(2),
|
||
dsx1D4(3),
|
||
dsx1E1(4),
|
||
dsx1E1CRC(5),
|
||
dsx1E1MF(6),
|
||
dsx1E1CRCMF(7),
|
||
dsx1Unframed(8),
|
||
dsx1E1Unframed(9),
|
||
dsx1DS2M12(10),
|
||
dsx1E2(11),
|
||
dsx1E1Q50(12),
|
||
dsx1E1Q50CRC(13),
|
||
dsx1SFCAS(14),
|
||
dsx1ESFCAS(15),
|
||
notApplicable(16)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Additional line types. For reference see object dsx1LineType"
|
||
::= { prvtCESDsx1ExtEntry 4 }
|
||
|
||
prvtCEST1LongCableLength OBJECT-TYPE
|
||
SYNTAX T1LongCableLength
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Long cable length options for T1 mode."
|
||
::= { prvtCESDsx1ExtEntry 5 }
|
||
|
||
prvtCESPortOperStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
up(1),
|
||
down(2),
|
||
testing(3),
|
||
unknown(4),
|
||
dormant(5),
|
||
notPresent(6),
|
||
lowerlayerDown(7)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"TDM link state."
|
||
::= { prvtCESDsx1ExtEntry 6 }
|
||
|
||
prvtCESClearPortStatistics OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
none ( 0 ),
|
||
clear ( 1 )
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Clear port statistics."
|
||
::= { prvtCESDsx1ExtEntry 7 }
|
||
|
||
prvtCESServiceClock OBJECT-TYPE
|
||
SYNTAX ServiceClock
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Service Clock available only for DS1 interface."
|
||
::= { prvtCESDsx1ExtEntry 8 }
|
||
|
||
prvtCESUnappTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PrvtCESUnappEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This table displays CES module configuration which will take effect
|
||
after prvtCESModuleConf is set to applyConfiguration(2)."
|
||
::= { prvtCESObjects 3 }
|
||
|
||
prvtCESUnappEntry OBJECT-TYPE
|
||
SYNTAX PrvtCESUnappEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"prvtCESUnappEntry"
|
||
AUGMENTS { dsx1ConfigEntry }
|
||
::= { prvtCESUnappTable 1 }
|
||
|
||
PrvtCESUnappEntry ::= SEQUENCE {
|
||
prvtCESUnappLineType INTEGER,
|
||
prvtCESUnappLineCoding INTEGER,
|
||
prvtCESUnappLoopbackConfig INTEGER,
|
||
prvtCESUnappSignalMode INTEGER,
|
||
prvtCESUnappTransmitClockSource INTEGER,
|
||
prvtCESUnappTransmitClockBackup INTEGER,
|
||
prvtCESUnappLineLength Integer32,
|
||
prvtCESUnappLineMode INTEGER,
|
||
prvtCESUnappLineBuildOut INTEGER,
|
||
prvtCESUnappE1Impedance E1Impedance,
|
||
prvtCESUnappT1GainLimit T1GainLimit,
|
||
prvtCESUnappIPAddress IpAddress,
|
||
prvtCESUnappIPAddressMask IpAddress,
|
||
prvtCESUnappGateway IpAddress
|
||
}
|
||
|
||
prvtCESUnappLineType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
dsx1ESF(2),
|
||
dsx1D4(3),
|
||
dsx1E1(4),
|
||
dsx1E1CRC(5),
|
||
dsx1E1MF(6),
|
||
dsx1E1CRCMF(7),
|
||
dsx1Unframed(8),
|
||
dsx1E1Unframed(9),
|
||
dsx1DS2M12(10),
|
||
dsx1E2(11),
|
||
dsx1E1Q50(12),
|
||
dsx1E1Q50CRC(13)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of dsx1LineType before configuration is applied."
|
||
::= { prvtCESUnappEntry 1 }
|
||
|
||
prvtCESUnappLineCoding OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
dsx1JBZS (1),
|
||
dsx1B8ZS (2),
|
||
dsx1HDB3 (3),
|
||
dsx1ZBTSI (4),
|
||
dsx1AMI (5),
|
||
other(6),
|
||
dsx1B6ZS(7)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of dsx1LineCoding before configuration is applied."
|
||
::= { prvtCESUnappEntry 2 }
|
||
|
||
prvtCESUnappLoopbackConfig OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
dsx1NoLoop(1),
|
||
dsx1PayloadLoop(2),
|
||
dsx1LineLoop(3),
|
||
dsx1OtherLoop(4),
|
||
dsx1InwardLoop(5),
|
||
dsx1DualLoop(6)
|
||
}
|
||
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of dsx1LoopbackConfig before configuration is applied."
|
||
::= { prvtCESUnappEntry 3 }
|
||
|
||
prvtCESUnappSignalMode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
none (1),
|
||
robbedBit (2),
|
||
bitOriented (3),
|
||
messageOriented (4),
|
||
other (5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of dsx1SignalMode before configuration is applied."
|
||
::= { prvtCESUnappEntry 4 }
|
||
|
||
prvtCESUnappTransmitClockSource OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
loopTiming(1),
|
||
localTiming(2),
|
||
throughTiming(3),
|
||
adaptive (4),
|
||
external-port (5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of dsx1TransmitClockSource before configuration is applied."
|
||
::= { prvtCESUnappEntry 5 }
|
||
|
||
prvtCESUnappTransmitClockBackup OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
enable (1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of dsx1TransmitClockBackup before configuration is applied."
|
||
::= { prvtCESUnappEntry 6 }
|
||
|
||
prvtCESUnappLineLength OBJECT-TYPE
|
||
SYNTAX Integer32 (0..64000)
|
||
UNITS "meters"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of dsx1LineLength before configuration is applied."
|
||
::= { prvtCESUnappEntry 7 }
|
||
|
||
prvtCESUnappLineMode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
csu(1),
|
||
dsu(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of dsx1LineMode before configuration is applied."
|
||
::= { prvtCESUnappEntry 8 }
|
||
|
||
prvtCESUnappLineBuildOut OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
notApplicable (1),
|
||
neg75dB (2),
|
||
neg15dB (3),
|
||
neg225dB (4),
|
||
zerodB (5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of dsx1LineBuildOut before configuration is applied."
|
||
::= { prvtCESUnappEntry 9 }
|
||
|
||
prvtCESUnappE1Impedance OBJECT-TYPE
|
||
SYNTAX E1Impedance
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of prvtCESE1Impedance before configuration is applied."
|
||
::= { prvtCESUnappEntry 10 }
|
||
|
||
prvtCESUnappT1GainLimit OBJECT-TYPE
|
||
SYNTAX T1GainLimit
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of prvtCEST1GainLimit before configuration is applied."
|
||
::= { prvtCESUnappEntry 11 }
|
||
|
||
prvtCESUnappIPAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The CES Module IP address before configuration is applied."
|
||
::= { prvtCESUnappEntry 12 }
|
||
|
||
prvtCESUnappIPAddressMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The CES Module IP address mask before configuration is applied."
|
||
::= { prvtCESUnappEntry 13 }
|
||
|
||
prvtCESUnappGateway OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The CES Module Gateway before configuration is applied."
|
||
::= { prvtCESUnappEntry 14 }
|
||
|
||
prvtCESModuleConfTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PrvtCESModuleConfEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This table contains object for configuring options that are applied to the entire module."
|
||
::= { prvtCESObjects 2 }
|
||
|
||
prvtCESModuleConfEntry OBJECT-TYPE
|
||
SYNTAX PrvtCESModuleConfEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"prvtCESModuleConfEntry"
|
||
INDEX {prvtCESModuleIndex}
|
||
::= { prvtCESModuleConfTable 1 }
|
||
|
||
PrvtCESModuleConfEntry ::= SEQUENCE {
|
||
prvtCESModuleIndex Integer32,
|
||
prvtCESModuleLineType CESLineType,
|
||
prvtCESModuleTxClock INTEGER,
|
||
prvtCESModuleTxBackupClock INTEGER,
|
||
prvtCESModuleConfig ConfigAction,
|
||
prvtCESModuleIPAddress IpAddress,
|
||
prvtCESModuleIPAddressMask IpAddress,
|
||
prvtCESModuleGateway IpAddress,
|
||
prvtCESModuleUpTime TimeStamp,
|
||
prvtCESModuleMACAddress OCTET STRING,
|
||
prvtCESModuleHardwareRevision OCTET STRING,
|
||
prvtCESModuleFirmwareVersion OCTET STRING,
|
||
prvtCESModuleClearCircuitStatistics INTEGER,
|
||
prvtCESModuleLbit INTEGER,
|
||
prvtCESModulePolicyLops INTEGER,
|
||
prvtCESModulePolicyLbit INTEGER,
|
||
prvtCESModulePolicyRbit INTEGER,
|
||
prvtCESModulePolicyRd INTEGER,
|
||
prvtCESModulePolicyIdlePattern Unsigned32,
|
||
prvtCESModulePolicyIdleSignalling Unsigned32,
|
||
prvtCESModulePolicyLopsEnter Integer32,
|
||
prvtCESModulePolicyLopsExit Integer32,
|
||
prvtCESModulePolicyuUnstrLbit INTEGER,
|
||
prvtCESModulePolicyuStrReplace INTEGER,
|
||
prvtCESModulePolicyuUnstrReplace INTEGER,
|
||
prvtCESModulePolicyuUnstrLops INTEGER,
|
||
prvtCESModuleServiceClock ServiceClock,
|
||
prvtCESModulePolicyuUnstrReplacePattern Integer32
|
||
}
|
||
|
||
prvtCESModuleIndex OBJECT-TYPE
|
||
SYNTAX Integer32(1..65535)
|
||
MAX-ACCESS accessible-for-notify
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index of each CES module installed."
|
||
::= { prvtCESModuleConfEntry 1 }
|
||
|
||
prvtCESModuleLineType OBJECT-TYPE
|
||
SYNTAX CESLineType
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Line mode for the module."
|
||
::= { prvtCESModuleConfEntry 2 }
|
||
|
||
prvtCESModuleTxClock OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
loopTiming(1),
|
||
localTiming(2),
|
||
throughTiming(3),
|
||
adaptive (4),
|
||
external-port (5),
|
||
line (6),
|
||
ptp(7)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Configures Transmit Source Clock for the module."
|
||
::= { prvtCESModuleConfEntry 3 }
|
||
|
||
prvtCESModuleTxBackupClock OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
enable (1),
|
||
disable (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Configures Backup Clock for the module."
|
||
::= { prvtCESModuleConfEntry 4 }
|
||
|
||
prvtCESModuleConfig OBJECT-TYPE
|
||
SYNTAX ConfigAction
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"When this object is set to applyConfiguration(2), the module is restarted
|
||
and the changes in dsx1ConfigTable or prvtCESConfTable are applied. The object
|
||
must be set to rejectConfiguration(3) to remove unapplied changes. If the object
|
||
is set to restart(4), the module is restarted with applying the changes.
|
||
This object always returns a value of noop(1) when get."
|
||
::= { prvtCESModuleConfEntry 5 }
|
||
|
||
prvtCESModuleIPAddress OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The CES Module IP address after configuration is applied."
|
||
::= { prvtCESModuleConfEntry 6 }
|
||
|
||
prvtCESModuleIPAddressMask OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The CES Module IP address mask after configuration is applied."
|
||
::= { prvtCESModuleConfEntry 7 }
|
||
|
||
prvtCESModuleGateway OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
" CES Module Gateway after configuration is applied."
|
||
::= { prvtCESModuleConfEntry 8 }
|
||
|
||
prvtCESModuleUpTime OBJECT-TYPE
|
||
SYNTAX TimeStamp
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"CES Up Time"
|
||
::= { prvtCESModuleConfEntry 9 }
|
||
|
||
prvtCESModuleMACAddress OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"CES MAC Address"
|
||
::= { prvtCESModuleConfEntry 10 }
|
||
|
||
prvtCESModuleHardwareRevision OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" CES Hardware revision"
|
||
::= { prvtCESModuleConfEntry 11 }
|
||
|
||
prvtCESModuleFirmwareVersion OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
" CES Firmware revision"
|
||
::= { prvtCESModuleConfEntry 12 }
|
||
|
||
prvtCESModuleClearCircuitStatistics OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
none ( 0 ),
|
||
clear ( 1 )
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Clear circuits statistics."
|
||
::= { prvtCESModuleConfEntry 13 }
|
||
|
||
prvtCESModuleLbit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
enable ( 1 ),
|
||
disable ( 2 )
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Enable/disable L bit set upon AIS
|
||
defect detection, in structure agnostic mode."
|
||
::= { prvtCESModuleConfEntry 14 }
|
||
|
||
prvtCESModulePolicyLops OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
idle ( 0 ),
|
||
all-one ( 1 ),
|
||
channel-idle ( 2 ),
|
||
none ( 3 )
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Controls policy lops. Object does not require module to be restarted."
|
||
::= { prvtCESModuleConfEntry 15 }
|
||
|
||
prvtCESModulePolicyLbit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
idle ( 0 ),
|
||
all-one ( 1 ),
|
||
channel-idle ( 2 ),
|
||
none ( 3 )
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Controls policy lbit. Object does not require module to be restarted."
|
||
::= { prvtCESModuleConfEntry 16 }
|
||
|
||
prvtCESModulePolicyRbit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
none ( 0 ),
|
||
rai ( 1 ),
|
||
channel-idle ( 2 )
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Controls policy rbit. Object does not require module to be restarted."
|
||
::= { prvtCESModuleConfEntry 17 }
|
||
|
||
prvtCESModulePolicyRd OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
none ( 0 ),
|
||
rai ( 1 ),
|
||
channel-idle ( 2 )
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Controls policy rd. Object does not require module to be restarted."
|
||
::= { prvtCESModuleConfEntry 18 }
|
||
|
||
prvtCESModulePolicyIdlePattern OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Controls policy idle pattern. Object does not require module to be restarted."
|
||
::= { prvtCESModuleConfEntry 19 }
|
||
|
||
prvtCESModulePolicyIdleSignalling OBJECT-TYPE
|
||
SYNTAX Unsigned32 (1..15)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION "Controls policy idle signalling. Object does not require module to be restarted."
|
||
::= { prvtCESModuleConfEntry 20 }
|
||
|
||
prvtCESModulePolicyLopsEnter OBJECT-TYPE
|
||
SYNTAX Integer32 (1..1023)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Controls the number of consecutive missed
|
||
packets required to enter LOPS state.
|
||
Object does not require module to be restarted."
|
||
::= {prvtCESModuleConfEntry 21}
|
||
|
||
prvtCESModulePolicyLopsExit OBJECT-TYPE
|
||
SYNTAX Integer32 (1..1023)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Controls the number of consecutive missed
|
||
packets required to exit LOPS state.
|
||
Object does not require module to be restarted."
|
||
::= {prvtCESModuleConfEntry 22}
|
||
|
||
prvtCESModulePolicyuUnstrLbit OBJECT-TYPE
|
||
SYNTAX INTEGER{
|
||
none(0),
|
||
all-one(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If a packet is received with L bit set, and the payload is present (not suppressed),
|
||
one of the following is sent to the TDM line, according to a globally configurable unstructured L-flag policy:
|
||
The AIS pattern all-one
|
||
The received payload as-is none"
|
||
DEFVAL { all-one }
|
||
::= {prvtCESModuleConfEntry 23}
|
||
|
||
prvtCESModulePolicyuStrReplace OBJECT-TYPE
|
||
SYNTAX INTEGER{
|
||
all-one(1),
|
||
idle (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If a missing packet is detected, one of the following is sent to the TDM line,
|
||
according to a globally configurable structured missing packet replacement policy:
|
||
The AIS pattern all-one on the relevant timeslots
|
||
The configured IDLE pattern"
|
||
DEFVAL { all-one }
|
||
::= {prvtCESModuleConfEntry 24}
|
||
|
||
prvtCESModulePolicyuUnstrReplace OBJECT-TYPE
|
||
SYNTAX INTEGER{
|
||
all-one(1),
|
||
idle (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If a missing packet is detected, one of the following is sent to the TDM line,
|
||
according to a globally configurable unstructured missing packet replacement policy:
|
||
The AIS pattern all-one
|
||
The configured IDLE pattern"
|
||
DEFVAL { all-one }
|
||
::= {prvtCESModuleConfEntry 25}
|
||
|
||
|
||
prvtCESModulePolicyuUnstrLops OBJECT-TYPE
|
||
SYNTAX INTEGER{
|
||
none(0),
|
||
all-one(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If a CES circuit enters the LOPS state, one of the following is sent to the TDM line,
|
||
according to a globally configurable unstructured missing packet replacement policy:
|
||
The AIS pattern all-one
|
||
The contents of the jitter buffer - none"
|
||
DEFVAL { all-one }
|
||
::= {prvtCESModuleConfEntry 26}
|
||
|
||
prvtCESModuleServiceClock OBJECT-TYPE
|
||
SYNTAX ServiceClock
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Clock mode for CES module"
|
||
::= {prvtCESModuleConfEntry 27}
|
||
|
||
|
||
prvtCESModulePolicyuUnstrReplacePattern OBJECT-TYPE
|
||
SYNTAX Integer32 (1..255)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Unstructured packet replace policy pattern number"
|
||
::= {prvtCESModuleConfEntry 28}
|
||
prvtCESDsx1AlarmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PrvtCESDsx1AlarmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This table contains object for configuring and displaying TDM ports TCA thresholds."
|
||
::= { prvtCESObjects 4 }
|
||
|
||
prvtCESDsx1AlarmEntry OBJECT-TYPE
|
||
SYNTAX PrvtCESDsx1AlarmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"prvtCESDsx1AlarmEntry"
|
||
INDEX {prvtCESDsx1AlarmPort,prvtCESDsx1AlarmIndex}
|
||
::= { prvtCESDsx1AlarmTable 1 }
|
||
|
||
PrvtCESDsx1AlarmEntry ::= SEQUENCE {
|
||
prvtCESDsx1AlarmPort Integer32,
|
||
prvtCESDsx1AlarmIndex Gauge32,
|
||
prvtCESDsx1AlarmVariable OBJECT IDENTIFIER,
|
||
prvtCESDsx1AlarmThreshold Integer32,
|
||
prvtCESDsx1AlarmValue Integer32
|
||
}
|
||
|
||
prvtCESDsx1AlarmPort OBJECT-TYPE
|
||
SYNTAX Integer32(1..65535)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
" The DS1 port for which this alarm is configured. "
|
||
::= { prvtCESDsx1AlarmEntry 1 }
|
||
|
||
prvtCESDsx1AlarmIndex OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
" An integer uniquely identifying an alarm entry."
|
||
::= { prvtCESDsx1AlarmEntry 2 }
|
||
|
||
prvtCESDsx1AlarmVariable OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The OID of the variable whose value is being monitored. Depending on the time interval,
|
||
the error condition and the ifIndex of the TDM interface, this points to an object from an entry in
|
||
dsx1CurrentTable or dsx1TotalTable."
|
||
::= { prvtCESDsx1AlarmEntry 3 }
|
||
|
||
prvtCESDsx1AlarmThreshold OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The alarm condition threshold for this alarm entry. The alarm is triggered if the value of the
|
||
object pointed by prvtCESDsx1AlarmVariable remains above this threshold for more than 3 seconds."
|
||
::= { prvtCESDsx1AlarmEntry 4 }
|
||
|
||
prvtCESDsx1AlarmValue OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS accessible-for-notify
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The value of the object pointed to by prvtCESDsx1AlarmVariable, present for notification purposes."
|
||
::= { prvtCESDsx1AlarmEntry 5 }
|
||
|
||
prvtCESAlarmMonitor OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"CES alarm monitor"
|
||
DEFVAL { enable }
|
||
::= { prvtCESObjects 5 }
|
||
|
||
prvtCESCICTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PrvtCESCICEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This table contains objects for configuring Clock Input Controller."
|
||
::= { prvtCESObjects 6 }
|
||
|
||
prvtCESCICEntry OBJECT-TYPE
|
||
SYNTAX PrvtCESCICEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"prvtCESCICEntry"
|
||
INDEX {prvtCESCICModuleId,prvtCESCICNumber}
|
||
::= { prvtCESCICTable 1 }
|
||
|
||
PrvtCESCICEntry ::= SEQUENCE {
|
||
prvtCESCICModuleId Integer32,
|
||
prvtCESCICNumber Gauge32,
|
||
prvtCESCICClockNumber Integer32,
|
||
prvtCESCICMode INTEGER,
|
||
prvtCESCICTdmPort Integer32,
|
||
prvtCESCICCircuit Integer32,
|
||
prvtCESCICStatus INTEGER,
|
||
prvtCESCICState INTEGER
|
||
}
|
||
|
||
prvtCESCICModuleId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..255)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Slot of CES module installed."
|
||
::= {prvtCESCICEntry 1}
|
||
|
||
prvtCESCICNumber OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
" An integer uniquely identifying a Clock Input Controller."
|
||
::= {prvtCESCICEntry 2}
|
||
|
||
prvtCESCICClockNumber OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This variable indicates the index of the clock
|
||
the clock input controller belongs to"
|
||
::= {prvtCESCICEntry 3}
|
||
|
||
prvtCESCICMode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
freeRun (1),
|
||
acquisition (2),
|
||
normal (3),
|
||
holdover (4),
|
||
fastAcquisiton (5)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The mode of the clock input controller. Not
|
||
all clock input controllers support all modes.
|
||
The clock input controller status is 'locked'
|
||
only if the clock input controller is in
|
||
'normal' mode."
|
||
::= {prvtCESCICEntry 4}
|
||
|
||
prvtCESCICTdmPort OBJECT-TYPE
|
||
SYNTAX Integer32 (0..4)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If the clock input controller recovers a clock
|
||
from a port , this variable indicates the
|
||
TDM Port. Otherwise, it must
|
||
be set to zero."
|
||
::= {prvtCESCICEntry 5}
|
||
|
||
prvtCESCICCircuit OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If the clock input controller recovers a clock
|
||
from a circuit, this variable indicates the
|
||
circuit ID. Otherwise, it
|
||
must be set to zero."
|
||
::= {prvtCESCICEntry 6}
|
||
|
||
prvtCESCICStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
locked (1),
|
||
notlocked (2),
|
||
sourceInputLost (3),
|
||
sourceInputDegraded (4),
|
||
sourceTraceLost (5),
|
||
sourceTraceDegraded (6),
|
||
sourceFreqOffsetFailure (7),
|
||
recoveredClockDegraded (8),
|
||
localReferenceFailure (9),
|
||
remoteReferenceFailure (10)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The status of the input reference.Reference
|
||
is ok when the status is 'locked'. Otherwise,
|
||
the status is 'notLocked'. Alternatively, if an
|
||
error was detected at the input, the status
|
||
indicates this error."
|
||
::= {prvtCESCICEntry 7}
|
||
|
||
prvtCESCICState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
active (1),
|
||
backup (2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The state is set to 'active' if the input
|
||
controller was selected by the clock to drive
|
||
the clock output. At least one input out of
|
||
the clock-input-controllers attached to a
|
||
clock must be in an 'active' state at any given
|
||
time"
|
||
::= {prvtCESCICEntry 8}
|
||
|
||
--
|
||
--
|
||
--
|
||
prvtCESCICMappTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PrvtCESCICMappEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This table contains clock configuration and status monitoring information."
|
||
::= { prvtCESObjects 7 }
|
||
|
||
prvtCESCICMappEntry OBJECT-TYPE
|
||
SYNTAX PrvtCESCICMappEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"prvtCESCICMappEntry"
|
||
INDEX {prvtCESCICMappModuleId,prvtCESCICMappClockNumber,prvtCESCICMappCICNumber}
|
||
::= { prvtCESCICMappTable 1 }
|
||
|
||
PrvtCESCICMappEntry ::= SEQUENCE {
|
||
prvtCESCICMappModuleId Integer32,
|
||
prvtCESCICMappClockNumber Gauge32,
|
||
prvtCESCICMappCICNumber Gauge32,
|
||
prvtCESCICMappState INTEGER
|
||
}
|
||
|
||
prvtCESCICMappModuleId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..255)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Slot of CES module installed."
|
||
::= {prvtCESCICMappEntry 1}
|
||
|
||
prvtCESCICMappClockNumber OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for the conceptual row
|
||
identifying a clock within this
|
||
mapping table"
|
||
::= {prvtCESCICMappEntry 2}
|
||
|
||
prvtCESCICMappCICNumber OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for the conceptual row
|
||
identifying a clock input within
|
||
this mapping table"
|
||
::= {prvtCESCICMappEntry 3}
|
||
|
||
prvtCESCICMappState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
active (1),
|
||
backup (2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The state is set to 'active' if the input
|
||
controller was selected by the clock to drive
|
||
the clock output. At least one input out of
|
||
the clock-input-controllers attached to a
|
||
clock must be in an 'active' state at any given
|
||
time This value of this variable is
|
||
equal to the prvtCESCICState
|
||
variable in the CIC table"
|
||
::= {prvtCESCICMappEntry 4}
|
||
|
||
prvtCESApsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PrvtCESApsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This table contains objects needed APS configuration"
|
||
::= { prvtCESObjects 8 }
|
||
|
||
prvtCESApsEntry OBJECT-TYPE
|
||
SYNTAX PrvtCESApsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"prvtCESApsEntry"
|
||
INDEX {prvtCESModuleId}
|
||
::= { prvtCESApsTable 1 }
|
||
|
||
PrvtCESApsEntry ::= SEQUENCE {
|
||
prvtCESApsModuleId Integer32,
|
||
prvtCESApsEnable INTEGER,
|
||
prvtCESApsActiveLine Integer32,
|
||
prvtSdBerThreshold Integer32,
|
||
prvtSfBerThreshold Integer32
|
||
}
|
||
|
||
prvtCESApsModuleId OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An integer uniquely identifying slot of the CES module installed"
|
||
::= {prvtCESApsEntry 1}
|
||
|
||
prvtCESApsEnable OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
enable (1),
|
||
disable (2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/Disable Automatic Protection Switching"
|
||
DEFVAL { enable }
|
||
::= {prvtCESApsEntry 2}
|
||
|
||
prvtCESApsActiveLine OBJECT-TYPE
|
||
SYNTAX Integer32(1..2)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"APS active line"
|
||
::= {prvtCESApsEntry 3}
|
||
|
||
prvtSdBerThreshold OBJECT-TYPE
|
||
SYNTAX Integer32(5..9)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Signal Degrade Bit Error Rate.
|
||
The negated value of this number is used
|
||
as the exponent of 10 for computing the
|
||
threshold value for the Bit Error Rate
|
||
(BER). For example, a value of 5 indicates
|
||
a BER threshold of 10^-5."
|
||
::= {prvtCESApsEntry 4}
|
||
|
||
prvtSfBerThreshold OBJECT-TYPE
|
||
SYNTAX Integer32(3..5)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Signal Failure Bit Error Rate.
|
||
The negated value of this number is used
|
||
as the exponent of 10 for computing the
|
||
threshold value for the Bit Error Rate
|
||
(BER). For example, a value of 5 indicates
|
||
a BER threshold of 10^-5."
|
||
::= {prvtCESApsEntry 5}
|
||
|
||
prvtCESUpdateFirmwareTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PrvtCESUpdateFirmwareEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This table contains object needed in update firmware of CES module"
|
||
::= { prvtCESObjects 9 }
|
||
|
||
prvtCESUpdateFirmwareEntry OBJECT-TYPE
|
||
SYNTAX PrvtCESUpdateFirmwareEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"prvtCESUpdateFirmwareEntry"
|
||
INDEX {prvtCESModuleId}
|
||
::= { prvtCESUpdateFirmwareTable 1 }
|
||
|
||
PrvtCESUpdateFirmwareEntry ::= SEQUENCE {
|
||
prvtCESModuleId Integer32,
|
||
prvtCESFirmwareImageName OCTET STRING,
|
||
prvtCESUpdateAction INTEGER,
|
||
prvtCESUpdateStatus INTEGER,
|
||
prvtCESTFTPServer IpAddress
|
||
}
|
||
|
||
prvtCESModuleId OBJECT-TYPE
|
||
SYNTAX Integer32 (1..32000)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An integer uniquely identifying slot of the CES module installed"
|
||
::= {prvtCESUpdateFirmwareEntry 1}
|
||
|
||
prvtCESFirmwareImageName OBJECT-TYPE
|
||
SYNTAX OCTET STRING
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Name of the firmware image file "
|
||
::= {prvtCESUpdateFirmwareEntry 2}
|
||
|
||
prvtCESUpdateAction OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
none (1),
|
||
update (2),
|
||
updateThroughUART (3)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Update CES firmware "
|
||
::= {prvtCESUpdateFirmwareEntry 3}
|
||
|
||
prvtCESUpdateStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
updateStatusUnknown (1),
|
||
updateSuccess (2),
|
||
updateInProgress (3),
|
||
updateFailed (4)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The status of the last update procedure, if any. This
|
||
object will have a value of updateStatusUnknown(2) if no
|
||
update process has been performed."
|
||
::= {prvtCESUpdateFirmwareEntry 4}
|
||
|
||
prvtCESTFTPServer OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"IP Address of Tftp Server"
|
||
::= {prvtCESUpdateFirmwareEntry 5}
|
||
|
||
prvtCESDsx1Alarm NOTIFICATION-TYPE
|
||
OBJECTS {prvtCESDsx1AlarmVariable,prvtCESDsx1AlarmThreshold,prvtCESDsx1AlarmValue}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This notification is sent when the value of a TDM port error condition statistic has exceeded the
|
||
configured threshold."
|
||
::= {prvtCESNotifications 1}
|
||
|
||
prvtCESModuleAvailable NOTIFICATION-TYPE
|
||
OBJECTS {prvtCESModuleIndex}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"prvtCESModuleAvailable trap"
|
||
::= {prvtCESNotifications 2}
|
||
|
||
prvtCESModuleUnAvailableDueExtract NOTIFICATION-TYPE
|
||
OBJECTS {prvtCESModuleIndex}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"prvtCESModuleUnAvailableDueExtract trap."
|
||
::= {prvtCESNotifications 3}
|
||
|
||
prvtCESModuleUnAvailableDueReload NOTIFICATION-TYPE
|
||
OBJECTS {prvtCESModuleIndex}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"prvtCESModuleUnAvailableDueReload trap"
|
||
::= {prvtCESNotifications 4}
|
||
--
|
||
-- Conformance Information
|
||
--
|
||
|
||
prvtCESDsx1Compliances OBJECT IDENTIFIER ::= { prvtCESConformance 1 }
|
||
prvtCESDsx1Groups OBJECT IDENTIFIER ::= { prvtCESConformance 2 }
|
||
|
||
-- compliance statements
|
||
prvtCESDsx1Compliance MODULE-COMPLIANCE
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The compliance statement for management of TDM ports."
|
||
MODULE -- this module
|
||
MANDATORY-GROUPS {
|
||
prvtCESDsx1NotificationsGroup,
|
||
prvtCESDsx1ROGroup
|
||
}
|
||
::= { prvtCESDsx1Compliances 1 }
|
||
|
||
prvtCESDsx1NotificationsGroup NOTIFICATION-GROUP
|
||
NOTIFICATIONS { prvtCESDsx1Alarm }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The group of supported notifications."
|
||
::= { prvtCESDsx1Groups 1 }
|
||
prvtCESDsx1ROGroup OBJECT-GROUP
|
||
OBJECTS { prvtCESE1Impedance,
|
||
prvtCEST1GainLimit,
|
||
prvtCESModuleLineType,
|
||
prvtCESModuleTxClock,
|
||
prvtCESModuleConfig,
|
||
prvtCESModuleIPAddress,
|
||
prvtCESModuleIPAddressMask,
|
||
prvtCESModuleGateway,
|
||
prvtCESDsx1AlarmThreshold
|
||
}
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The group of objects with MAX-ACCESS read-write supported with read-only access for the first release."
|
||
::= { prvtCESDsx1Groups 2 }
|
||
|
||
END
|