Files
librenms-librenms/mibs/telco-systems/binos/PRVT-MONITOR-SESSION-MIB
Tony MurrayandGitHub 11147d3bbf Major Processors rewrite (#8066)
* Extract DiscoveryItem and move some things to better places.
Extract model class
Fix up model construction.  I have problem with construction...
Makeshift model working.  Switch constructor to factory.  discover() and create()
Support legacy discovery.
Remove uneeded custom pollers
Remove netonix custom detection as we try ucd on all os now.
Add a few yaml procs.  Fix a couple things.
More processor discovery conversions
Move Calix e7 to standard hrProcessorLoad, but it doesn't fully implement the HR-MIB, move things around to make it work.
Add a few yaml procs.  Fix a couple things. Correct some stupid mib stuff.
Move more, drop php 5.3
Add netscaler which uses string indexes.  Port fiberhome to yaml and use skip_values
More conversions.  BroadcomProcessorUsage Trait
Serveriron and Ironware share some mibs.  Create a common abstract os for them.
Add yaml support for mib specification in each data entry
Make legacy discover_processor() set 0 for hrDeviceIndex

Untangle Dell switch OS processors

Use use shared OS for groups if they don't have a specific group.
fix silly mib mistake

Make index optional

Move HR and UCD to Traits and out of Processor.

* forgot to update the fortiswitch index

* Make sgos and avaya-ers match the old index.

* fix comware test data

* fix merge errors

* fix dsm and remove pointless empty modules

* file not found exception is in the wrong place.

* Updated processor development docs
2018-02-05 07:39:13 -06:00

298 lines
8.6 KiB
Plaintext
Raw Permalink Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
-- *********************************************************************
-- *********************************************************************
-- ** Filename: PRVT-NETWORK-LOOPBACK-TEST-MIB
-- ** Project: Network Loopback Tester
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications.
-- BATM Advanced Communications retains all title and
-- ownership in the Specification, including any revisions.
-- BATM Advanced Communications grants all interested parties a non-exclusive
-- license to use and distribute an unmodified copy of this
-- Specification in connection with management of BATM Advanced Communications
-- and Telco Systems products, and without fee, provided that the following
-- conditions are met:
-- 1. Redistributions of this specification must retain the above copyright
-- notice, this list of conditions and the following disclaimer.
-- 2. Redistributions in binary form must reproduce the above copyright
-- notice, this list of conditions and the following disclaimer in the
-- documentation and/or other materials provided with the distribution.
-- 3. The name of the BATM Advanced Communications MAY NOT be used to endorse
-- or promote products derived from this specification without specific prior written
-- permission.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SPECIFICATIONS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SPECIFICATION CONTAINED IN THIS FILE.
PRVT-MONITOR-SESSION-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Integer32
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP
FROM SNMPv2-CONF
-- [RFC2578]
DisplayString,
TEXTUAL-CONVENTION
FROM SNMPv2-TC
PortList
FROM Q-BRIDGE-MIB
switch
FROM PRVT-SWITCH-MIB;
-- The MONITOR SESSION MIB
prvtMonitorSessionMib MODULE-IDENTITY
LAST-UPDATED "201105230000Z"
ORGANIZATION "BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: [email protected]
For North Europe: [email protected], [email protected]
For the rest of the world: [email protected]"
DESCRIPTION
"This MIB contains manageable objects for
encapsulating Switched Port Analyzer(SPAN) feature."
REVISION "201105230000Z"
DESCRIPTION
"Initial version."
::= { switch 1000 }
-- -------------------------------------------------------------
-- Textual Conventions
-- -------------------------------------------------------------
Direction ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Monitor direction:
tx- Transmit
rx- Receive"
SYNTAX INTEGER
{
rx(1),
tx(2)
}
-- -------------------------------------------------------------
-- groups in the PRVT-MONITOR-SESSION MIB
-- -------------------------------------------------------------
prvtMonitorSessionNotification OBJECT IDENTIFIER ::= { prvtMonitorSessionMib 0 }
prvtMonitorSessionObjects OBJECT IDENTIFIER ::= { prvtMonitorSessionMib 1 }
prvtMonitorSessionConformance OBJECT IDENTIFIER ::= { prvtMonitorSessionMib 2 }
-- -------------------------------------------------------------
-- prvtMonitorSessionObjects group
-- -------------------------------------------------------------
prvtMonitorSessionTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtMonitorSessionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains object for enable and configure Enable Switched Port Analyzer."
::= { prvtMonitorSessionObjects 1 }
prvtMonitorSessionEntry OBJECT-TYPE
SYNTAX PrvtMonitorSessionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table will describe all parameteres of Switched Port Analyzer per each direction Rx or Tx "
INDEX { prvtMonitorSessionDirection }
::= {prvtMonitorSessionTable 1}
PrvtMonitorSessionEntry ::= SEQUENCE{
prvtMonitorSessionDirection Direction,
prvtMonitorSessionSource PortList,
prvtMonitorSessionDestination Integer32
}
prvtMonitorSessionDirection OBJECT-TYPE
SYNTAX Direction
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Direction recived/trasmitted of the monitored traffic."
::= {prvtMonitorSessionEntry 1}
prvtMonitorSessionSource OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Monitored source list representing the ports to be mirrored."
::= {prvtMonitorSessionEntry 2}
prvtMonitorSessionDestination OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Analyzer port."
::= {prvtMonitorSessionEntry 3}
prvtAnalyzerVLANTagTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtAnalyzerVLANTagEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains object for enable and configure Remote Analyzer VLAN Tag"
::= { prvtMonitorSessionObjects 2 }
prvtAnalyzerVLANTagEntry OBJECT-TYPE
SYNTAX PrvtAnalyzerVLANTagEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table will describe all parameteres of Remote Analyzer VLAN Tag per each direction Rx or Tx "
INDEX { prvtMonitorSessionDirection }
::= {prvtAnalyzerVLANTagTable 1}
PrvtAnalyzerVLANTagEntry ::= SEQUENCE{
prvtAnalyzerVLANTagEnable INTEGER,
prvtAnalyzerVLANTagVID Integer32,
prvtAnalyzerVLANTagEtherType DisplayString,
prvtAnalyzerVLANTagCFI INTEGER,
prvtAnalyzerVLANTagVPT INTEGER
}
prvtAnalyzerVLANTagEnable OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable Remote Analyzer VLAN Tag."
::= {prvtAnalyzerVLANTagEntry 1}
prvtAnalyzerVLANTagVID OBJECT-TYPE
SYNTAX Integer32 (1..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The VLAN ID of the VLAN tag added to packet forwarded to Analyzer."
::= {prvtAnalyzerVLANTagEntry 2}
prvtAnalyzerVLANTagEtherType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Vlan ether type of the VLAN tag added to packet forwarded to Analyzer."
::= {prvtAnalyzerVLANTagEntry 3}
prvtAnalyzerVLANTagCFI OBJECT-TYPE
SYNTAX INTEGER
{
clear(0),
set(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The CFI of the VLAN tag added to packet forwarded to Analyzer."
::= {prvtAnalyzerVLANTagEntry 4}
prvtAnalyzerVLANTagVPT OBJECT-TYPE
SYNTAX INTEGER
{
vpt-value0(0),
vpt-value1(1),
vpt-value2(2),
vpt-value3(3),
vpt-value4(4),
vpt-value5(5),
vpt-value6(6),
vpt-value7(7),
undefined(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The VPT of the VLAN tag added to packet forwarded to Analyzer."
::= {prvtAnalyzerVLANTagEntry 5}
-- ----------------------------------------------------------------------------
-- Notifications
-- ----------------------------------------------------------------------------
-- ----------------------------------------------------------------------------
-- Conformance Information
-- ----------------------------------------------------------------------------
prvtMonitorSessionCompliances OBJECT IDENTIFIER ::= {prvtMonitorSessionConformance 1}
prvtMonitorSessionGroups OBJECT IDENTIFIER ::= {prvtMonitorSessionConformance 2}
-- compliance statements
prvtMonitorSessionCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for Switched Port Analyzer."
MODULE -- this module
MANDATORY-GROUPS {
prvtMonitorSessionMirroredGroup,
prvtMonitorSessionAnalyzerGroup
}
::= {prvtMonitorSessionCompliances 1}
prvtMonitorSessionMirroredGroup OBJECT-GROUP
OBJECTS {
prvtMonitorSessionSource
} STATUS current
DESCRIPTION
"The group of objects dedicated to mirrored source."
::= {prvtMonitorSessionGroups 1}
prvtMonitorSessionAnalyzerGroup OBJECT-GROUP
OBJECTS {
prvtMonitorSessionDestination,
prvtAnalyzerVLANTagEnable
} STATUS current
DESCRIPTION
"The group of objects dedicated to analyzer."
::= {prvtMonitorSessionGroups 2}
END