Files
librenms-librenms/mibs/telco-systems/binos/PRVT-RESILIENT-LINK-MIB
Tony MurrayandGitHub 11147d3bbf Major Processors rewrite (#8066)
* Extract DiscoveryItem and move some things to better places.
Extract model class
Fix up model construction.  I have problem with construction...
Makeshift model working.  Switch constructor to factory.  discover() and create()
Support legacy discovery.
Remove uneeded custom pollers
Remove netonix custom detection as we try ucd on all os now.
Add a few yaml procs.  Fix a couple things.
More processor discovery conversions
Move Calix e7 to standard hrProcessorLoad, but it doesn't fully implement the HR-MIB, move things around to make it work.
Add a few yaml procs.  Fix a couple things. Correct some stupid mib stuff.
Move more, drop php 5.3
Add netscaler which uses string indexes.  Port fiberhome to yaml and use skip_values
More conversions.  BroadcomProcessorUsage Trait
Serveriron and Ironware share some mibs.  Create a common abstract os for them.
Add yaml support for mib specification in each data entry
Make legacy discover_processor() set 0 for hrDeviceIndex

Untangle Dell switch OS processors

Use use shared OS for groups if they don't have a specific group.
fix silly mib mistake

Make index optional

Move HR and UCD to Traits and out of Processor.

* forgot to update the fortiswitch index

* Make sgos and avaya-ers match the old index.

* fix comware test data

* fix merge errors

* fix dsm and remove pointless empty modules

* file not found exception is in the wrong place.

* Updated processor development docs
2018-02-05 07:39:13 -06:00

252 lines
8.8 KiB
Plaintext

-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-RESILIENT-LINK-MIB.mib
-- ** Project: T - Ethernet and Fast Ethernet IP Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
--
PRVT-RESILIENT-LINK-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
NOTIFICATION-TYPE FROM SNMPv2-SMI
NOTIFICATION-GROUP FROM SNMPv2-CONF
switch FROM PRVT-SWITCH-MIB;
-------------------------------------------------------------------------------
-- PRIVATE BRANCH PRODUCTS
-------------------------------------------------------------------------------
prvtResilientLinkMib MODULE-IDENTITY
LAST-UPDATED "200502160000Z"
ORGANIZATION "BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: [email protected]
For North Europe: [email protected], [email protected]
For the rest of the world: [email protected]"
DESCRIPTION
"The Resilient Link MIB module for managing switch or ipSwitch
resilient link"
-- revision history
REVISION "200502160000Z"
DESCRIPTION
"Fixed spelling errors and changed the contact info."
REVISION "200305060000Z"
DESCRIPTION
"Move to SMI-V2."
REVISION "200201280000Z"
DESCRIPTION
"Initial version."
::= { switch 102 }
-- -----------------------------------------------------------------------------
-- resilient link configuration parameters
-- -----------------------------------------------------------------------------
prvtResilientLinkNotifications OBJECT IDENTIFIER ::= { prvtResilientLinkMib 0 }
resilientLinkConfig OBJECT IDENTIFIER ::= { prvtResilientLinkMib 1 }
resilientLinkStatus OBJECT IDENTIFIER ::= { prvtResilientLinkMib 2 }
prvtResilientLinkConformance OBJECT IDENTIFIER ::= { prvtResilientLinkMib 3 }
resilientLinkConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ResilientLinkConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the resilient link configuration."
::= { resilientLinkConfig 1 }
resilientLinkConfigEntry OBJECT-TYPE
SYNTAX ResilientLinkConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"resilientLinkIndex"
INDEX { resilientLinkIndex }
::= { resilientLinkConfigTable 1 }
ResilientLinkConfigEntry ::= SEQUENCE {
resilientLinkIndex INTEGER,
resilientLinkEnable INTEGER,
resilientLinkPort1ifIndex INTEGER,
resilientLinkPort2ifIndex INTEGER,
resilientLinkPreferredPort INTEGER,
resilientLinkActivePort INTEGER
}
resilientLinkIndex OBJECT-TYPE
SYNTAX INTEGER(0..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the resilient link"
::= { resilientLinkConfigEntry 1 }
resilientLinkEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables or disables the resilient link"
::= { resilientLinkConfigEntry 2 }
resilientLinkPort1ifIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the first port belonging to this
resilient link; zero means no port is selected"
::= { resilientLinkConfigEntry 3 }
resilientLinkPort2ifIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the second port belonging to this
resilient link; zero means no port is selected"
::= { resilientLinkConfigEntry 4 }
resilientLinkPreferredPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the preferred port (1 or 2) in this
resilient link; zero means no port is preferred"
::= { resilientLinkConfigEntry 5 }
resilientLinkActivePort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the active port (1 or 2) in this
resilient link. Only ports with link up can be configured as active
ports."
::= { resilientLinkConfigEntry 6 }
-- -----------------------------------------------------------------------------
-- resilient link status
-- -----------------------------------------------------------------------------
resilientLinkStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ResilientLinkStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the resilient link status."
::= { resilientLinkStatus 2 }
resilientLinkStatusEntry OBJECT-TYPE
SYNTAX ResilientLinkStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"resilientLinkIndex"
INDEX { resilientLinkIndex }
::= { resilientLinkStatusTable 1 }
ResilientLinkStatusEntry ::= SEQUENCE {
resilientLinkConnectedPort INTEGER,
resilientLinkCurrentActivePort INTEGER
}
resilientLinkConnectedPort OBJECT-TYPE
SYNTAX INTEGER {
notConnected(1),
port1Connected(2),
port2Connected(3),
port1and2Connected(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the connected ports in the resilient link"
::= { resilientLinkStatusEntry 1 }
resilientLinkCurrentActivePort OBJECT-TYPE
SYNTAX INTEGER {
noActivePort (1),
port1Active (2),
port2Active (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the active port (1 or 2) in this
resilient link. Only ports with link up can be configured as active
ports."
::= { resilientLinkStatusEntry 2 }
-- Traps for use by prvtResilientLinkMib
resilientLinkStatusChange NOTIFICATION-TYPE
OBJECTS { resilientLinkIndex, resilientLinkConnectedPort,
resilientLinkCurrentActivePort}
STATUS current
DESCRIPTION
"The resilientLinkStatusChange trap indicates that
the sending agent monitor detected a change in the status of the
resilient link, identified by resilientLinkIndex."
::= {prvtResilientLinkNotifications 1}
-- *******************************************************************
-- Conformance Information
-- *******************************************************************
prvtResilientLinkMIBGroups OBJECT IDENTIFIER ::= { prvtResilientLinkConformance 2 }
resilientLinkNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
resilientLinkStatusChange
}
STATUS current
DESCRIPTION
"Private Notification Group."
::= { prvtResilientLinkMIBGroups 3 }
END