ELS100-S24TX2M-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
IMPORTS
 | 
						|
        internet
 | 
						|
                FROM RFC1155-SMI
 | 
						|
        MODULE-IDENTITY, OBJECT-TYPE, Integer32, IpAddress
 | 
						|
                FROM SNMPv2-SMI
 | 
						|
        DisplayString
 | 
						|
                FROM SNMPv2-TC;
 | 
						|
 | 
						|
 | 
						|
-- private             OBJECT IDENTIFIER ::= { internet 4 }
 | 
						|
-- enterprises         OBJECT IDENTIFIER ::= { private 1 }
 | 
						|
-- cabletron           OBJECT IDENTIFIER ::= { enterprises 52 }
 | 
						|
-- namingTree          OBJECT IDENTIFIER ::= { cabletron 3 }
 | 
						|
-- mtExpanded          OBJECT IDENTIFIER ::= { namingTree 9 }
 | 
						|
-- mtThrdParty         OBJECT IDENTIFIER ::= { mtExpanded 1 }
 | 
						|
-- tpStandAlone        OBJECT IDENTIFIER ::= { mtThrdParty 10 }
 | 
						|
 | 
						|
 | 
						|
tpELS100S24TX2M     MODULE-IDENTITY
 | 
						|
        LAST-UPDATED    "200202202202Z"  -- Wed Feb 20 22:02 GMT 2002
 | 
						|
        ORGANIZATION    "Enterasys Networks, Inc."
 | 
						|
        CONTACT-INFO
 | 
						|
            "Enterasys Networks, Inc.
 | 
						|
             35 Industrial Way, P.O. Box 5005
 | 
						|
             Rochester, NH 03867-5005
 | 
						|
             (603) 332-9400
 | 
						|
             support@enterasys.com
 | 
						|
             http://www.enterasys.com"
 | 
						|
        DESCRIPTION
 | 
						|
                "The MIB module for ELS100-S24TX2M."
 | 
						|
 | 
						|
        REVISION  "200208051753Z"  -- Mon Aug  5 17:53 GMT 2002
 | 
						|
        DESCRIPTION
 | 
						|
                "Added switchOIDTable for identifying the individual
 | 
						|
                 switches in a stack of switches."
 | 
						|
 | 
						|
        REVISION  "200202202202Z"  -- Wed Feb 20 22:02 GMT 2002
 | 
						|
        DESCRIPTION
 | 
						|
                "Pretty print."
 | 
						|
 | 
						|
        REVISION  "199910010000Z"
 | 
						|
        DESCRIPTION
 | 
						|
                "Initial version of this MIB."
 | 
						|
        -- ::= { tpStandAlone 7 }
 | 
						|
        ::= { internet private(4) enterprises(1) cabletron(52)
 | 
						|
                       namingTree(3) mtExpanded(9) mtThrdParty(1)
 | 
						|
                       tpStandAlone(10) tpELS100S24TX2M(7) }
 | 
						|
 | 
						|
 | 
						|
switchInfo          OBJECT IDENTIFIER ::= { tpELS100S24TX2M 1 }
 | 
						|
switchPortMgt       OBJECT IDENTIFIER ::= { tpELS100S24TX2M 2 }
 | 
						|
systemSTAMgt        OBJECT IDENTIFIER ::= { tpELS100S24TX2M 3 }
 | 
						|
tftpDownloadMgt     OBJECT IDENTIFIER ::= { tpELS100S24TX2M 4 }
 | 
						|
restartMgt          OBJECT IDENTIFIER ::= { tpELS100S24TX2M 5 }
 | 
						|
portMirrorMgt       OBJECT IDENTIFIER ::= { tpELS100S24TX2M 6 }
 | 
						|
igmpMgt             OBJECT IDENTIFIER ::= { tpELS100S24TX2M 7 }
 | 
						|
 | 
						|
 | 
						|
--
 | 
						|
-- switchInfo
 | 
						|
--
 | 
						|
 | 
						|
switchNumber  OBJECT-TYPE
 | 
						|
        SYNTAX      Integer32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "The total number of switches present on this system." 
 | 
						|
        ::= { switchInfo 1 } 
 | 
						|
 | 
						|
 | 
						|
switchInfoTable OBJECT-TYPE
 | 
						|
        SYNTAX      SEQUENCE OF SwitchInfoEntry
 | 
						|
        MAX-ACCESS  not-accessible
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Table of descriptive and status information about
 | 
						|
             switches in this system."
 | 
						|
        ::= { switchInfo 2 }
 | 
						|
 | 
						|
switchInfoEntry OBJECT-TYPE
 | 
						|
        SYNTAX      SwitchInfoEntry
 | 
						|
        MAX-ACCESS  not-accessible
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "An entry in the table, containing information
 | 
						|
             about a single switch in this system. "
 | 
						|
        INDEX { swUnitIndex }
 | 
						|
        ::= { switchInfoTable 1 }
 | 
						|
 | 
						|
SwitchInfoEntry ::= SEQUENCE
 | 
						|
{
 | 
						|
        swUnitIndex             Integer32,
 | 
						|
        swMainBoardHwVer        DisplayString,
 | 
						|
        swMainBoardFwVer        DisplayString,
 | 
						|
        swAgentBoardHwVer       DisplayString,
 | 
						|
        swAgentBoardFwVer       DisplayString,
 | 
						|
        swAgentBoardPOSTCodeVer DisplayString,
 | 
						|
        swPortNumber            Integer32,
 | 
						|
        swPowerStatus           INTEGER,
 | 
						|
        swExpansionSlot1        INTEGER,
 | 
						|
        swExpansionSlot2        INTEGER,
 | 
						|
        swRoleInSystem          INTEGER
 | 
						|
}
 | 
						|
 | 
						|
swUnitIndex         OBJECT-TYPE
 | 
						|
        SYNTAX      Integer32
 | 
						|
        MAX-ACCESS  not-accessible
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "This object identifies the switch within the system
 | 
						|
             for which this entry contains information. This
 | 
						|
             value can never be greater than switchNumber."
 | 
						|
        ::= { switchInfoEntry 1 }
 | 
						|
 | 
						|
swMainBoardHwVer   OBJECT-TYPE
 | 
						|
        SYNTAX     DisplayString (SIZE(0..20))
 | 
						|
        MAX-ACCESS read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Hardware version of the main board."
 | 
						|
        ::= { switchInfoEntry 2 }
 | 
						|
 | 
						|
swMainBoardFwVer   OBJECT-TYPE
 | 
						|
        SYNTAX     DisplayString (SIZE(0..20))
 | 
						|
        MAX-ACCESS read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Firmware version of the main board."
 | 
						|
        ::= { switchInfoEntry 3 }
 | 
						|
 | 
						|
swAgentBoardHwVer  OBJECT-TYPE
 | 
						|
        SYNTAX     DisplayString (SIZE(0..20))
 | 
						|
        MAX-ACCESS read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Hardware version of the agent board."
 | 
						|
        ::= { switchInfoEntry 4 }
 | 
						|
 | 
						|
swAgentBoardFwVer  OBJECT-TYPE
 | 
						|
        SYNTAX     DisplayString (SIZE(0..20))
 | 
						|
        MAX-ACCESS read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Firmware version of the agent board."
 | 
						|
        ::= { switchInfoEntry 5 }
 | 
						|
 | 
						|
swAgentBoardPOSTCodeVer    OBJECT-TYPE
 | 
						|
        SYNTAX     DisplayString (SIZE(0..20))
 | 
						|
        MAX-ACCESS read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "POST code version of the agent board."
 | 
						|
        ::= { switchInfoEntry 6 }
 | 
						|
 | 
						|
swPortNumber       OBJECT-TYPE
 | 
						|
        SYNTAX     Integer32
 | 
						|
        MAX-ACCESS read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "The total port number of this switch
 | 
						|
             (including expansion slot)." 
 | 
						|
        ::= { switchInfoEntry 7 } 
 | 
						|
 | 
						|
swPowerStatus      OBJECT-TYPE
 | 
						|
        SYNTAX     INTEGER {
 | 
						|
              internalPower(1),
 | 
						|
              redundantPower(2),
 | 
						|
              internalAndRedundantPower(3)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Indicates the switch using internalPower(1), 
 | 
						|
             redundantPower(2) or both(3)"
 | 
						|
        ::= { switchInfoEntry 8 }
 | 
						|
 | 
						|
swExpansionSlot1   OBJECT-TYPE
 | 
						|
        SYNTAX     INTEGER {
 | 
						|
              hundredBaseFX2Port(1),
 | 
						|
              thousandBaseSX(2),
 | 
						|
              stackingModule4GB(3),
 | 
						|
              hundredBaseFX1Port(4),
 | 
						|
              thousandBaseLX(5),
 | 
						|
              thousandBaseT(6),
 | 
						|
              thousandBaseGBIC(7),
 | 
						|
              stackingModule2GB(8),
 | 
						|
              other(9),
 | 
						|
              notPresent(10)                        
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Type of expansion module in this switch slot 1."
 | 
						|
        ::= { switchInfoEntry 9 }
 | 
						|
 | 
						|
swExpansionSlot2    OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER {
 | 
						|
              hundredBaseFX2Port(1),
 | 
						|
              thousandBaseSX(2),
 | 
						|
              stackingModule4GB(3),
 | 
						|
              hundredBaseFX1Port(4),
 | 
						|
              thousandBaseLX(5),
 | 
						|
              thousandBaseT(6),
 | 
						|
              thousandBaseGBIC(7),
 | 
						|
              stackingModule2GB(8),
 | 
						|
              other(9),
 | 
						|
              notPresent(10)                        
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Type of expansion module in this switch slot 2."
 | 
						|
        ::= { switchInfoEntry 10 }
 | 
						|
 | 
						|
swRoleInSystem      OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER {
 | 
						|
              master(1),
 | 
						|
              backupMaster(2),
 | 
						|
              slave(3)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Indicates the switch is master(1), backupMaster(2)
 | 
						|
             or slave(3) in this system."
 | 
						|
        ::= { switchInfoEntry 11 }
 | 
						|
 | 
						|
 | 
						|
switchOIDTable OBJECT-TYPE
 | 
						|
        SYNTAX      SEQUENCE OF SwitchOIDEntry
 | 
						|
        MAX-ACCESS  not-accessible
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Table of System Object Identifiers for switches
 | 
						|
             in this system."
 | 
						|
        ::= { switchInfo 3 }
 | 
						|
 | 
						|
switchOIDEntry OBJECT-TYPE
 | 
						|
        SYNTAX      SwitchOIDEntry
 | 
						|
        MAX-ACCESS  not-accessible
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "An entry in the table, containing System Object
 | 
						|
             Identifier for a single switch in this system."
 | 
						|
        INDEX { switchOIDIndex }
 | 
						|
        ::= { switchOIDTable 1 }
 | 
						|
 | 
						|
SwitchOIDEntry ::= SEQUENCE
 | 
						|
{
 | 
						|
    switchOIDIndex          INTEGER,
 | 
						|
    switchOIDValue          OBJECT IDENTIFIER
 | 
						|
}
 | 
						|
 | 
						|
switchOIDIndex OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER( 1 .. 65535 )
 | 
						|
        MAX-ACCESS  not-accessible
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "This object identifies the switch within the system
 | 
						|
             for which this entry contains information. This
 | 
						|
             value can never be greater than switchNumber.
 | 
						|
 | 
						|
             Index value 1 always represents the Master in a
 | 
						|
             stacked configuration and the only device in a
 | 
						|
             standalone configuration.
 | 
						|
 | 
						|
             Subsequent indices are sequential with the lowest
 | 
						|
             number representing the Slave nearest the Master
 | 
						|
             and so on."
 | 
						|
        ::= { switchOIDEntry 1 }
 | 
						|
 | 
						|
switchOIDValue OBJECT-TYPE
 | 
						|
        SYNTAX      OBJECT IDENTIFIER
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "This object contains the System Object Identifier
 | 
						|
             that uniquely identifies the type of switch."
 | 
						|
        ::= { switchOIDEntry 2 }
 | 
						|
 | 
						|
 | 
						|
--
 | 
						|
-- switchPortMgt
 | 
						|
--
 | 
						|
 | 
						|
switchPortMgtTable  OBJECT-TYPE
 | 
						|
        SYNTAX      SEQUENCE OF SwitchPortMgtEntry
 | 
						|
        MAX-ACCESS  not-accessible
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Table of descriptive and status information about
 | 
						|
             configuration of each switch ports (including
 | 
						|
             expansion slot) in this system."
 | 
						|
        ::= { switchPortMgt 1 }
 | 
						|
 | 
						|
switchPortMgtEntry  OBJECT-TYPE
 | 
						|
        SYNTAX      SwitchPortMgtEntry
 | 
						|
        MAX-ACCESS  not-accessible
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "An entry in the table, containing information about
 | 
						|
             configuration in one switch port of the switch."
 | 
						|
        INDEX { swUnitIndex, swPortMgtIndex }
 | 
						|
        ::= { switchPortMgtTable 1 }
 | 
						|
 | 
						|
SwitchPortMgtEntry ::= SEQUENCE
 | 
						|
{
 | 
						|
        swPortMgtIndex              Integer32,
 | 
						|
        swPortMgtPortType           INTEGER,
 | 
						|
        swPortMgtSpeedDpxAdmin      INTEGER,
 | 
						|
        swPortMgtSpeedDpxInUse      INTEGER,
 | 
						|
        swPortMgtFlowCtrlAdmin      INTEGER,
 | 
						|
        swPortMgtFlowCtrlInUse      INTEGER
 | 
						|
}
 | 
						|
 | 
						|
swPortMgtIndex      OBJECT-TYPE
 | 
						|
        SYNTAX      Integer32
 | 
						|
        MAX-ACCESS  not-accessible
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "This object identifies the port within the switch
 | 
						|
             for which this entry contains information."
 | 
						|
        ::= { switchPortMgtEntry 1 } 
 | 
						|
 | 
						|
swPortMgtPortType   OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER {
 | 
						|
              hundredBaseTX(1),
 | 
						|
              hundredBaseFX(2),
 | 
						|
              thousandBaseSX(3)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Indicates the port type is tenBaseT/hundredBaseTX(1),
 | 
						|
             hundredBaseFX(2) or thousandBaseSX(3)."
 | 
						|
        ::= { switchPortMgtEntry 2 }
 | 
						|
 | 
						|
swPortMgtSpeedDpxAdmin  OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER {
 | 
						|
              halfDuplex10(1),
 | 
						|
              fullDuplex10(2),
 | 
						|
              halfDuplex100(3),
 | 
						|
              fullDuplex100(4),
 | 
						|
              halfDuplex1000(5),
 | 
						|
              fullDuplex1000(6),
 | 
						|
              autoNegotiation(7)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Set the port speed and duplex mode as follows:       
 | 
						|
                halfDuplex10(1)    - 10Mbps and half duplex mode
 | 
						|
                fullDuplex10(2)    - 10Mbps and full duplex mode
 | 
						|
                halfDuplex100(3)   - 100Mbps and half duplex mode
 | 
						|
                fullDuplex100(4)   - 100Mbps and full duplex mode
 | 
						|
                halfDuplex1000(5)  - 1000Mbps and half duplex mode
 | 
						|
                fullDuplex1000(6)  - 1000Mbps and full duplex mode
 | 
						|
                autoNegotiation(7) - let the switch to negotiate with
 | 
						|
                                     the other end of connection.
 | 
						|
                hundredBaseTX port can be set as
 | 
						|
                             halfDuplex10(1)
 | 
						|
                             fullDuplex10(2)
 | 
						|
                             halfDuplex100(3)
 | 
						|
                             fullDuplex100(4)
 | 
						|
                             autoNegotiation(7)
 | 
						|
 | 
						|
                hundredBaseFX port can be set as
 | 
						|
                             halfDuplex100(3)
 | 
						|
                             fullDuplex100(4)
 | 
						|
 | 
						|
                thousandBaseSX port can be set as
 | 
						|
                             halfDuplex1000(5)
 | 
						|
                             fullDuplex1000(6)
 | 
						|
                             autoNegotiation(7)       
 | 
						|
 | 
						|
             The actual operating speed and duplex of the port is
 | 
						|
             given by swPortMgtSpeedDpxInUse."
 | 
						|
        DEFVAL { autoNegotiation }
 | 
						|
        ::= { switchPortMgtEntry 3 }
 | 
						|
 | 
						|
swPortMgtSpeedDpxInUse  OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER {
 | 
						|
              halfDuplex10(1),
 | 
						|
              fullDuplex10(2),
 | 
						|
              halfDuplex100(3),
 | 
						|
              fullDuplex100(4),
 | 
						|
              halfDuplex1000(5),
 | 
						|
              fullDuplex1000(6)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "The operating speed and duplex mode of the switched port."
 | 
						|
        ::= { switchPortMgtEntry 4 }
 | 
						|
 | 
						|
swPortMgtFlowCtrlAdmin OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER {
 | 
						|
              enabled(1),
 | 
						|
              disabled(2),
 | 
						|
              backPressure(3),
 | 
						|
              dot3xFlowControl(4)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "(1) Flow control mechanism is enabled.
 | 
						|
 | 
						|
                 If the port type is hundredBaseTX or thousandBaseSX:
 | 
						|
                     When the port is operating in halfDuplex mode,
 | 
						|
                       the port uses backPressure flow control mechanism.
 | 
						|
                     When the port is operating in fullDuplex mode,
 | 
						|
                       the port uses IEEE 802.3x flow control mechanism.
 | 
						|
 | 
						|
                 If the port type is hundredBaseFX: 
 | 
						|
                     When the port is operating in halfDuplex mode, the 
 | 
						|
                         port uses backPressure flow control mechanism. When
 | 
						|
                         the port is operating in fullDuplex mode, Flow
 | 
						|
                         control mechanism will not function.
 | 
						|
 | 
						|
             (2) Flow control mechanism is disabled. 
 | 
						|
 | 
						|
             (3) Flow control mechanism is backPressure.
 | 
						|
 | 
						|
                 When the port is in fullDuplex mode
 | 
						|
                    this flow control mechanism will not function.
 | 
						|
 | 
						|
             (4) Flow control mechanism is IEEE 802.3x flow control.
 | 
						|
 | 
						|
                    When the port is in halfDuplex mode
 | 
						|
                         this flow control mechanism will not function.
 | 
						|
 | 
						|
             hundredBaseTX and thousandBaseSX port can be set as:
 | 
						|
                  enabled(1),
 | 
						|
                  disabled(2),
 | 
						|
                  backPressure(3),
 | 
						|
                  dot3xFlowControl(4).
 | 
						|
 | 
						|
             hundredBaseFX port can be set as:
 | 
						|
                  enabled(1),
 | 
						|
                  disabled(2),
 | 
						|
                  backPressure(3).
 | 
						|
             The actual flow control mechanism is used given by
 | 
						|
             swPortMgtFlowCtrlInUse."
 | 
						|
        DEFVAL { enabled }
 | 
						|
        ::= { switchPortMgtEntry 5 }
 | 
						|
 | 
						|
swPortMgtFlowCtrlInUse  OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER {
 | 
						|
              backPressure(1),
 | 
						|
              dot3xFlowControl(2),
 | 
						|
              none(3)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "(1) BackPressure flow control mechanism is used.
 | 
						|
             (2) IEEE 802.3 flow control mechanism is used.
 | 
						|
             (3) Flow control mechanism is disabled. "
 | 
						|
        ::= { switchPortMgtEntry 6 }
 | 
						|
 | 
						|
 | 
						|
--
 | 
						|
-- systemSTAMgt
 | 
						|
--
 | 
						|
 | 
						|
systemSTAStatus     OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER { 
 | 
						|
              enabled(1),
 | 
						|
              disabled(2) 
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Global spanning tree status. 
 | 
						|
               (1) Spanning tree protocol is enabled. 
 | 
						|
               (2) Spanning tree protocol is disabled. "
 | 
						|
        DEFVAL  { enabled }
 | 
						|
        ::= { systemSTAMgt 1 }
 | 
						|
 | 
						|
--
 | 
						|
-- tftpDownloadMgt
 | 
						|
--
 | 
						|
 | 
						|
tftpDownloadServerIP OBJECT-TYPE
 | 
						|
        SYNTAX      IpAddress
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION 
 | 
						|
            "The IP address of a TFTP server from which a 
 | 
						|
             firmware image can be downloaded."
 | 
						|
        DEFVAL { '00000000'H }
 | 
						|
        ::= { tftpDownloadMgt 1 }
 | 
						|
 | 
						|
--tftpDownloadMainBoardFwFileName OBJECT-TYPE
 | 
						|
--        SYNTAX     DisplayString(SIZE(0..80))
 | 
						|
--        MAX-ACCESS read-write
 | 
						|
--        STATUS      current
 | 
						|
--        DESCRIPTION ""
 | 
						|
--        DEFVAL { "es3526f.bin" }
 | 
						|
--        ::= { tftpDownloadMgt 2 }
 | 
						|
 | 
						|
--tftpDownloadMainBoardFwSelected OBJECT-TYPE
 | 
						|
--        SYNTAX     INTEGER { 
 | 
						|
--              selected(1), 
 | 
						|
--              notSelected(2) 
 | 
						|
--        }
 | 
						|
--        MAX-ACCESS read-write
 | 
						|
--        STATUS     current
 | 
						|
--        DESCRIPTION 
 | 
						|
--            "Setting this object as selected. The system will download
 | 
						|
--             main board firmware when the download action be trigged."
 | 
						|
--        DEFVAL { notSelected }
 | 
						|
--        ::= { tftpDownloadMgt 3 }
 | 
						|
 | 
						|
tftpDownloadAgentBoardFwFileName OBJECT-TYPE
 | 
						|
        SYNTAX      DisplayString(SIZE(0..80))
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION ""
 | 
						|
        DEFVAL { "es3526f.bin" }
 | 
						|
        ::= { tftpDownloadMgt 2 }
 | 
						|
 | 
						|
tftpDownloadAgentBoardFwDownloadNode OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER { 
 | 
						|
              permanent(1), 
 | 
						|
              temporary(2) 
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION 
 | 
						|
            "Indicates whether a newly upgraded firmware
 | 
						|
             version should write to flash.  When this object
 | 
						|
             is temporary(2), following a successful upgrade
 | 
						|
             the system will switch to run the new firmware but
 | 
						|
             will not upgrade the new firmware to flash.  That
 | 
						|
             means after a power cycle, system will run the
 | 
						|
             firmware residing the flash.
 | 
						|
             When this object is permanent(1), following a
 | 
						|
             successful firmware upgrade, the flash will be
 | 
						|
             upgraded and the system will automatically switch
 | 
						|
             to run the new firmware."
 | 
						|
        DEFVAL { permanent }
 | 
						|
        ::= { tftpDownloadMgt 3 }
 | 
						|
 | 
						|
--tftpDownloadAgentBoardFwSelected  OBJECT-TYPE
 | 
						|
--        SYNTAX     INTEGER { 
 | 
						|
--              selected(1), 
 | 
						|
--              notSelected(2) 
 | 
						|
--        }
 | 
						|
--        MAX-ACCESS read-write
 | 
						|
--        STATUS      current
 | 
						|
--        DESCRIPTION 
 | 
						|
--            "Setting this object as selected. The system will download
 | 
						|
--             agent board firmware when the download action be trigged."
 | 
						|
--        DEFVAL { notSelected }
 | 
						|
--        ::= { tftpDownloadMgt 4 }
 | 
						|
 | 
						|
tftpDownloadStatus OBJECT-TYPE
 | 
						|
        SYNTAX     INTEGER { 
 | 
						|
              active(1), 
 | 
						|
              notActive(2) 
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION 
 | 
						|
            "Setting this object to active(1) trigger the TFTP
 | 
						|
             download action.  Setting this object to notActive(2)
 | 
						|
             has no effect.  The system always returns the value
 | 
						|
             notActive(2) when this object is read."
 | 
						|
  ::= { tftpDownloadMgt 4 }
 | 
						|
 | 
						|
--
 | 
						|
-- restartMgt
 | 
						|
--
 | 
						|
 | 
						|
restartOptionPOST  OBJECT-TYPE
 | 
						|
        SYNTAX     INTEGER { 
 | 
						|
              enabled(1),
 | 
						|
              disabled(2)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION 
 | 
						|
            "Setting this object as enabled. The system will do POST 
 | 
						|
             when it restart"
 | 
						|
        DEFVAL { enabled }
 | 
						|
        ::= { restartMgt 1 }
 | 
						|
 | 
						|
restartOptionReloadFactoryDefault   OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER { 
 | 
						|
              enabled(1),
 | 
						|
              disabled(2)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION 
 | 
						|
            "Setting this object as enabled. The system will do
 | 
						|
             factory reset when it restart"
 | 
						|
        DEFVAL { disabled }
 | 
						|
        ::= { restartMgt 2 }
 | 
						|
 | 
						|
restartOptionKeepIpSetting   OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER { 
 | 
						|
              enabled(1),
 | 
						|
              disabled(2)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION 
 | 
						|
            "Setting this object as enabled. The system will keep IP
 | 
						|
             setting when it do factory reset."
 | 
						|
        DEFVAL { enabled }
 | 
						|
        ::= { restartMgt 3 }
 | 
						|
 | 
						|
restartOptionKeepUserAuthentication   OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER { 
 | 
						|
              enabled(1),
 | 
						|
              disabled(2)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION 
 | 
						|
            "Setting this object as enabled. The system will keep
 | 
						|
             user authentication setting when it do factory reset."
 | 
						|
        DEFVAL { enabled }
 | 
						|
        ::= { restartMgt 4 }
 | 
						|
 | 
						|
restartAction   OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER { 
 | 
						|
              active(1), 
 | 
						|
              notActive(2) 
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION 
 | 
						|
            "Setting this object to active(1) trigger the system 
 | 
						|
             restart.  Setting this object to notActive(2) has
 | 
						|
             no effect.  The system always returns the value
 | 
						|
             notActive(2) when this object is read."
 | 
						|
        ::= { restartMgt 5 }
 | 
						|
 | 
						|
--
 | 
						|
-- portMirrorMgt
 | 
						|
--
 | 
						|
 | 
						|
portMirrorStatus    OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER { 
 | 
						|
              enabled(1),
 | 
						|
              disabled(2)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Port mirroring function status.
 | 
						|
                (1) mirroring function is enabled.
 | 
						|
                (2) mirroring function is disabled."
 | 
						|
        ::= { portMirrorMgt 1 }
 | 
						|
 | 
						|
portMirrorSnifferPort   OBJECT-TYPE
 | 
						|
        SYNTAX      Integer32
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Linear port number of sniffer port to which all
 | 
						|
             frames to/from mirrored ports are sent. Frames
 | 
						|
             are only mirrored if the portMirrorStatus object
 | 
						|
             is set to enabled(1)."
 | 
						|
        ::= { portMirrorMgt 2 }
 | 
						|
 | 
						|
 | 
						|
portMirrorMirroredPort  OBJECT-TYPE
 | 
						|
        SYNTAX      Integer32
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Linear port number of mirrored port. The traffic of
 | 
						|
             mirrored port will be 'copied' to sniffer port." 
 | 
						|
        ::= { portMirrorMgt 3 }
 | 
						|
 | 
						|
--
 | 
						|
-- igmpMgt
 | 
						|
--
 | 
						|
 | 
						|
igmpStatus          OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER {
 | 
						|
              enabled(1),
 | 
						|
              disabled(2)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Parameter to enable or disable IGMP snooping on the device.
 | 
						|
             When enabled, the device will examine IGMP packets and set
 | 
						|
             up filters for IGMP ports. The default is enabled."
 | 
						|
        ::= { igmpMgt 1 }
 | 
						|
 | 
						|
igmpQueryCount      OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER (2..16)
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Maximum number of queries that have not been heard on the
 | 
						|
             system before the system starts taking action to solicit
 | 
						|
             reports(default is 5)."
 | 
						|
        ::= { igmpMgt 2 }
 | 
						|
 | 
						|
 | 
						|
igmpReportDelay     OBJECT-TYPE
 | 
						|
        SYNTAX      INTEGER (3..10)
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS      current
 | 
						|
        DESCRIPTION
 | 
						|
            "Timeout value(mins) between IGMP reports received on a port
 | 
						|
             for an IP Multicast Address that can pass before the system
 | 
						|
             sends an IGMP Query out the port and removes it from the 
 | 
						|
             list(default is 5 minutes)." 
 | 
						|
        ::= { igmpMgt 3 }
 | 
						|
 | 
						|
END
 |