mirror of
				https://github.com/librenms/librenms.git
				synced 2024-10-07 16:52:45 +00:00 
			
		
		
		
	git-svn-id: http://www.observium.org/svn/observer/trunk@2811 61d68cd4-352d-0410-923a-c4978735b2b8
		
			
				
	
	
		
			1416 lines
		
	
	
		
			42 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			1416 lines
		
	
	
		
			42 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
-- *****************************************************************
 | 
						|
-- Senao EOR7550 Private MIB
 | 
						|
--
 | 
						|
-- Apr 2008, Adonn Fu
 | 
						|
--
 | 
						|
-- Copyright (c) 2000-2003 by Sendfar Technology Co., Ltd.
 | 
						|
-- All rights reserved.
 | 
						|
-- *****************************************************************
 | 
						|
 | 
						|
--module definition
 | 
						|
 | 
						|
SENAO-EOR7550-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
       IMPORTS
 | 
						|
       MODULE-IDENTITY, OBJECT-TYPE, 
 | 
						|
       Counter32, IpAddress, enterprises, TimeTicks        
 | 
						|
       FROM SNMPv2-SMI
 | 
						|
       DisplayString, MacAddress, TruthValue FROM SNMPv2-TC;
 | 
						|
 | 
						|
-- module OID definition
 | 
						|
   senao MODULE-IDENTITY
 | 
						|
   LAST-UPDATED "0511250000Z"
 | 
						|
   ORGANIZATION "Senao R&D Dept., S/W Division"
 | 
						|
   CONTACT-INFO
 | 
						|
       "
 | 
						|
       Info
 | 
						|
       SENAO INTERNATIONAL CO., LTD.
 | 
						|
       No.500, Fusing 3 Rd., Hwa-Ya Technical Park,
 | 
						|
       Kuei-Shan Hsiang, TAOYUAN County 333, TAIWAN, R.O.C.
 | 
						|
       Tel: 886-3-328-9289
 | 
						|
       Fax: 886-3-328-9666
 | 
						|
       E-mail: info@senao.com.tw
 | 
						|
       "
 | 
						|
   DESCRIPTION
 | 
						|
       "
 | 
						|
       The MIB module defines Senao implementation-specific metrics useful in managing 
 | 
						|
       IEEE 802.11 on Senao devices.
 | 
						|
       This is used as a supplement to the standard 802.11 MIB proposed by IEEE.
 | 
						|
       "
 | 
						|
   ::= { enterprises 14125}
 | 
						|
 | 
						|
	eor7550 OBJECT IDENTIFIER ::= { senao 101 }
 | 
						|
 | 
						|
	entSystem OBJECT IDENTIFIER ::= { eor7550 1 }
 | 
						|
	entLAN OBJECT IDENTIFIER ::= { eor7550 2 }
 | 
						|
	entWAN OBJECT IDENTIFIER ::= { eor7550 3 }
 | 
						|
	entMacFilter OBJECT IDENTIFIER ::= { eor7550 4}
 | 
						|
	entRalinkWlan OBJECT IDENTIFIER ::= { eor7550 5}
 | 
						|
	entSNMP OBJECT IDENTIFIER ::= { eor7550 6 }
 | 
						|
	entAthWlan OBJECT IDENTIFIER ::= { eor7550 7} 
 | 
						|
	                              
 | 
						|
	entWlanCommonInfo OBJECT IDENTIFIER ::= { entRalinkWlan 1}
 | 
						|
	entAthWlanCommonInfo OBJECT IDENTIFIER ::= { entAthWlan 1}
 | 
						|
 | 
						|
-- objects definition
 | 
						|
 | 
						|
--	entSystem OBJECT IDENTIFIER ::= { eor7550 1 }
 | 
						|
--	entAdminIdleTimeOut OBJECT-TYPE
 | 
						|
--		SYNTAX INTEGER (1..1000)
 | 
						|
--		MAX-ACCESS read-write
 | 
						|
--    	STATUS mandatory
 | 
						|
--		DESCRIPTION
 | 
						|
--			"Administration idle time out in mins"			
 | 
						|
--	::= { entSystem 1 }
 | 
						|
	          
 | 
						|
	entPassword OBJECT-TYPE
 | 
						|
		SYNTAX DisplayString  (SIZE (0..32))
 | 
						|
		MAX-ACCESS write-only
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Administration password"			
 | 
						|
	::= { entSystem 2 }
 | 
						|
	         
 | 
						|
	entSysModel OBJECT-TYPE
 | 
						|
		SYNTAX DisplayString
 | 
						|
    	MAX-ACCESS read-only
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"System model"			
 | 
						|
	::= { entSystem 3 }
 | 
						|
	          
 | 
						|
	entSysMode OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER
 | 
						|
		{
 | 
						|
			ap-router(0),
 | 
						|
			universal-repeater(1),
 | 
						|
			ap-bridge(2),
 | 
						|
			client-bridge(3),
 | 
						|
			client-router(4),
 | 
						|
			wds-bridge(5),
 | 
						|
			ap-router-repeater(6),
 | 
						|
			wds-repeater(7),
 | 
						|
			wds-router-repeater(8)
 | 
						|
		}
 | 
						|
    	MAX-ACCESS read-only
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"System mode, 0:AP router, 1:Repeater, 2: AP bridge, 
 | 
						|
			3: Client bridge, 4: Client router, 5: WDS bridge, 
 | 
						|
			6: AP router repeater, 7: WDS repeater, 8: WDS router repeater"			
 | 
						|
	::= { entSystem 4 }
 | 
						|
	
 | 
						|
	entSysUpTime OBJECT-TYPE
 | 
						|
		SYNTAX TimeTicks
 | 
						|
    	MAX-ACCESS read-only
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"System uptime"			
 | 
						|
	::= { entSystem 5 }
 | 
						|
 | 
						|
    entHwVersion OBJECT-TYPE
 | 
						|
        SYNTAX DisplayString 
 | 
						|
        MAX-ACCESS read-only
 | 
						|
        STATUS mandatory
 | 
						|
        DESCRIPTION 
 | 
						|
            "The version of the hardware"
 | 
						|
    ::= {  entSystem 6 }
 | 
						|
                     
 | 
						|
    entSN OBJECT-TYPE
 | 
						|
        SYNTAX DisplayString 
 | 
						|
        MAX-ACCESS read-only
 | 
						|
        STATUS mandatory
 | 
						|
        DESCRIPTION 
 | 
						|
            "Serial Number"
 | 
						|
    ::= {  entSystem 7 }
 | 
						|
 | 
						|
    entKenelVersion OBJECT-TYPE
 | 
						|
        SYNTAX DisplayString 
 | 
						|
        MAX-ACCESS read-only
 | 
						|
        STATUS mandatory
 | 
						|
        DESCRIPTION 
 | 
						|
            "The version of the kernel"
 | 
						|
    ::= {  entSystem 8 }
 | 
						|
 | 
						|
    entAppVersion OBJECT-TYPE
 | 
						|
        SYNTAX DisplayString 
 | 
						|
        MAX-ACCESS read-only
 | 
						|
        STATUS mandatory
 | 
						|
        DESCRIPTION 
 | 
						|
            "The version of the system application"
 | 
						|
    ::= {  entSystem 9 }
 | 
						|
    
 | 
						|
    entReset OBJECT-TYPE
 | 
						|
        SYNTAX TruthValue 
 | 
						|
        MAX-ACCESS write-only
 | 
						|
        STATUS mandatory
 | 
						|
        DESCRIPTION 
 | 
						|
            "Setting this attribute TRUE causes the AP rebooted"
 | 
						|
    ::= {  entSystem 10 }
 | 
						|
             
 | 
						|
     entResetToDefault OBJECT-TYPE
 | 
						|
        SYNTAX TruthValue 
 | 
						|
        MAX-ACCESS write-only
 | 
						|
        STATUS mandatory
 | 
						|
        DESCRIPTION 
 | 
						|
            "Setting this attribute TRUE will Reboot the system and change settings to factory default"
 | 
						|
    ::= {  entSystem 11 }
 | 
						|
 | 
						|
    entApplyModules OBJECT-TYPE
 | 
						|
        SYNTAX TruthValue 
 | 
						|
        MAX-ACCESS write-only
 | 
						|
        STATUS mandatory
 | 
						|
        DESCRIPTION 
 | 
						|
            "Setting this attribute TRUE will apply the changed modules to reload"
 | 
						|
    ::= {  entSystem 12 }
 | 
						|
            
 | 
						|
-- entLAN OBJECT IDENTIFIER ::= { eor7550 2 }
 | 
						|
	entLANIP OBJECT-TYPE
 | 
						|
		SYNTAX IpAddress
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"LAN IP address"			
 | 
						|
	::= { entLAN 1 }
 | 
						|
 | 
						|
	entLANSubnetMask OBJECT-TYPE
 | 
						|
		SYNTAX IpAddress
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"LAN subnet mask"			
 | 
						|
	::= { entLAN 2 }
 | 
						|
 | 
						|
	entSTPEnable OBJECT-TYPE
 | 
						|
		SYNTAX TruthValue
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Set this attribute TUUE will enable 802.1d Spanning Tree."			
 | 
						|
	::= { entLAN 3 }
 | 
						|
	
 | 
						|
	entDHCPEnable OBJECT-TYPE
 | 
						|
		SYNTAX TruthValue
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"When system mode is not 1(Repeater) and 5(WDS bridge), 
 | 
						|
			set this attribute TUUE will enable the DHCP server function of device"			
 | 
						|
	::= { entLAN 4 }
 | 
						|
	
 | 
						|
	entIPPoolStart OBJECT-TYPE
 | 
						|
		SYNTAX IpAddress
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"TWhen system mode is not 1(Repeater) and 5(WDS bridge), 
 | 
						|
			set the start address of DHCP IP pool"			
 | 
						|
	::= { entLAN 5 }
 | 
						|
                  
 | 
						|
	entIPPoolEnd OBJECT-TYPE
 | 
						|
		SYNTAX IpAddress
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"When system mode is not 1(Repeater) and 5(WDS bridge), 
 | 
						|
			set the end address of DHCP IP pool"			
 | 
						|
	::= { entLAN 6 }
 | 
						|
 | 
						|
	entIPLeaseTime OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER
 | 
						|
	   	{       
 | 
						|
	   		half-hour(0),
 | 
						|
			one-hour(1),
 | 
						|
			two-hours(2),
 | 
						|
			half-day(3),
 | 
						|
			one-day(4),
 | 
						|
			two-days(5),
 | 
						|
			one-week(6),
 | 
						|
			two-weeks(7),
 | 
						|
			forever(8)
 | 
						|
		}
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"When system mode is not 1(Repeater) and 5(WDS bridge), 
 | 
						|
			the time period client can have the IP address assigned by DHCP server
 | 
						|
			0(half hour), 
 | 
						|
			1(one hour)
 | 
						|
			2(two hours), 
 | 
						|
			3(half day),
 | 
						|
			4(one day), 
 | 
						|
			5(two days),
 | 
						|
			6(one week), 
 | 
						|
			7(two weeks),
 | 
						|
			8(forever)
 | 
						|
			"			
 | 
						|
	::= { entLAN 7 }
 | 
						|
 | 
						|
--	entWAN OBJECT IDENTIFIER ::= { eor7550 3 }
 | 
						|
	entRouterEnable OBJECT-TYPE
 | 
						|
		SYNTAX TruthValue
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Only When op mode is 0(AP) or (Client bridge), 
 | 
						|
			can set this attribute. Set TUUE will enable the router."			
 | 
						|
	::= { entWAN 1 }
 | 
						|
                     
 | 
						|
--	entMacFilter OBJECT IDENTIFIER ::= { eor7550 4 }         
 | 
						|
	entLanMacFilteringEnable OBJECT-TYPE
 | 
						|
		SYNTAX TruthValue
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Set this attribute TUUE will enable the LAN MAC filtering"			
 | 
						|
	::= { entMacFilter 1 }
 | 
						|
	     
 | 
						|
	entLanMacFilteringMode OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER
 | 
						|
		{
 | 
						|
			white-list(0),
 | 
						|
			black-list(1)		
 | 
						|
		}
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"The mode of LAN MAC filtering can be 0(white list), 1(black list)"			
 | 
						|
	::= { entMacFilter 2 }
 | 
						|
      
 | 
						|
	entLanMacFilterTable       OBJECT-TYPE
 | 
						|
	    SYNTAX          SEQUENCE OF EntLanMacFilterEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "This table provides one row for each LAN MAC filtering.
 | 
						|
	        Each row contains the enterprise LAN MAC filtering table
 | 
						|
	         for that LAN MAC filtering."
 | 
						|
	::= { entMacFilter 3 }
 | 
						|
	  
 | 
						|
	entLanMacFilterEntry       OBJECT-TYPE
 | 
						|
	    SYNTAX          EntLanMacFilterEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION     "An entry in the entLanMacFilterTable."
 | 
						|
	    INDEX           { entMacAddressIndex }
 | 
						|
	::= { entLanMacFilterTable 1 }
 | 
						|
                      
 | 
						|
 	EntLanMacFilterEntry ::=
 | 
						|
	  SEQUENCE {
 | 
						|
	  entMacAddressIndex		INTEGER,
 | 
						|
	  entMacAddress				MacAddress,
 | 
						|
	  entMacFilteringValid		TruthValue,
 | 
						|
	  }
 | 
						|
 | 
						|
 	entMacAddressIndex OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER
 | 
						|
	   	MAX-ACCESS  read-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "The auxiliary variable used to identify instances of 
 | 
						|
	        columnar objects in the LAN MAC Filtering Table"
 | 
						|
	::= { entLanMacFilterEntry 1 }  
 | 
						|
	   
 | 
						|
 	entMacAddress OBJECT-TYPE
 | 
						|
	    SYNTAX      DisplayString
 | 
						|
	   	MAX-ACCESS  read-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "MAC address list in the LAN MAC filtering table"
 | 
						|
	::= { entLanMacFilterEntry 2 } 	   
 | 
						|
	
 | 
						|
 	entMacFilteringValid OBJECT-TYPE
 | 
						|
	    SYNTAX      TruthValue
 | 
						|
	   	MAX-ACCESS  read-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "The validity status of each corresponding MAC address in LAN MAC filtering table"
 | 
						|
	::= { entLanMacFilterEntry 3 }     
 | 
						|
 
 | 
						|
--	entWlan OBJECT IDENTIFIER ::= { eor7550 5 }
 | 
						|
--	entWlanCommonInfo OBJECT IDENTIFIER ::= { entWlan 1}
 | 
						|
       
 | 
						|
	entOpMode OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER
 | 
						|
	   	{       
 | 
						|
			ap(0),
 | 
						|
			client-bridge(1),
 | 
						|
			client-router(2),
 | 
						|
			wds-bridge(3),
 | 
						|
			wds-repeater(4),
 | 
						|
			repeater-ap(5),
 | 
						|
			repeater-sta(6),
 | 
						|
			disable(7)
 | 
						|
		}
 | 
						|
		MAX-ACCESS read-only
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Get op mode: 0(AP), 1(Client bridge), 2(Client router),
 | 
						|
			3(WDS bridge), 4(WDS repeater), 5(Repeater ap), 6(Repeater station),
 | 
						|
			7(Disable)"			
 | 
						|
	::= { entWlanCommonInfo 1 }
 | 
						|
 | 
						|
    entRadio OBJECT-TYPE
 | 
						|
	    SYNTAX TruthValue 
 | 
						|
	    MAX-ACCESS  read-write
 | 
						|
	    STATUS  mandatory
 | 
						|
	    DESCRIPTION
 | 
						|
		    "Set this attribute TUUE will enable the radio"
 | 
						|
	::= { entWlanCommonInfo 2 }
 | 
						|
                     
 | 
						|
	entBand OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER
 | 
						|
	   	{       
 | 
						|
			ieee802dot11-b-g(0),
 | 
						|
			ieee802dot11-b(1),
 | 
						|
			ieee802dot11-g(4),
 | 
						|
			ieee802dot11-n(6),
 | 
						|
			ieee802dot11-b-g-n(9)
 | 
						|
		}
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"The wireless mode: 0(802.11 b/g),
 | 
						|
			1(802.11 b),
 | 
						|
			4(802.11 g),
 | 
						|
			6(802.11 n),
 | 
						|
			9(802.11 b/g/n)"			
 | 
						|
	::= { entWlanCommonInfo 4 }
 | 
						|
        
 | 
						|
	entESSIDNum OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER (1..4)
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Only when op mode for Ralink is 0(AP) and 5(Repeater AP),   
 | 
						|
			support multiple ESSID. Set the Number of multiple ESSID"			
 | 
						|
	::= { entWlanCommonInfo 5 }
 | 
						|
	          
 | 
						|
	entChannel OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER (1..14)
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Only when op mode for Ralink is 0(AP), 3(WDS bridge), 4(WDS repeater) and 5(Repeater AP),
 | 
						|
			the current operating frequency channel"			
 | 
						|
	::= { entWlanCommonInfo 6 }
 | 
						|
 | 
						|
	entDataRate OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER
 | 
						|
        {        
 | 
						|
        	auto(0),
 | 
						|
			oneMbps(1),
 | 
						|
			twoMbps(2),
 | 
						|
			fiveNhalfMbps(5), 
 | 
						|
			elevenMbps(11),
 | 
						|
			sixMbps(6),
 | 
						|
			nineMbps(9),	
 | 
						|
			twelveMbps(12),		
 | 
						|
			eighteenMbps(18),
 | 
						|
			twentytwoMbps(24),
 | 
						|
			thirtysixMbps(36),
 | 
						|
			fortyeightMbps(48),
 | 
						|
			fiftyfourMbps(54)
 | 
						|
		}
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"This attribute specifies the data rate at which the station may transmit data in Mbps
 | 
						|
			0(Auto), 1(1Mbps), 2(2Mbps), 5(5.5Mbps), 11(11Mbps), 6(6Mbps), 9(9Mbps), 12(12Mbps), 
 | 
						|
			18(18Mbps), 24(24Mbps), 36(36Mbps), 48(48Mbps), 54(54Mbps)"			
 | 
						|
	::= { entWlanCommonInfo 7 }
 | 
						|
       
 | 
						|
	entNDataRate OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER
 | 
						|
        {        
 | 
						|
        	auto(0),
 | 
						|
			mcs0(1),
 | 
						|
			mcs1(2),
 | 
						|
			mcs2(3),
 | 
						|
			mcs3(4),
 | 
						|
			mcs4(5),
 | 
						|
			mcs5(6),
 | 
						|
			mcs6(7),
 | 
						|
			mcs7(8),
 | 
						|
			mcs8(9),
 | 
						|
			mcs9(10),
 | 
						|
			mcs10(11),
 | 
						|
			mcs11(12),
 | 
						|
			mcs12(13),
 | 
						|
			mcs13(14),
 | 
						|
			mcs14(15),
 | 
						|
			mcs15(16)
 | 
						|
		}
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"This attribute specifies the 11n data rate"			
 | 
						|
	::= { entWlanCommonInfo 8 }
 | 
						|
     
 | 
						|
	entTxPower OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"The transmit power level: 10(%), 25(%), 50(%), 75(%), 90(%), 100(%)"			
 | 
						|
	::= { entWlanCommonInfo 9 }
 | 
						|
 | 
						|
	entBeaconInterval OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER (20..1024)
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"This attribute specifies the number of TU that a station shall use 
 | 
						|
			for scheduling Beacon transmissions"			
 | 
						|
	::= { entWlanCommonInfo 10 }
 | 
						|
          
 | 
						|
	entDTIMPeriod OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER (1..255)
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"This attribute specifies the number of beacon intervals"			
 | 
						|
	::= { entWlanCommonInfo 11 }
 | 
						|
              
 | 
						|
	entFragmentationThreshold OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER (256..2346)
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"This attribute shall specify the current maximum size, in octets, 
 | 
						|
			of the MPDU that may be delivered to the PHY"			
 | 
						|
	::= { entWlanCommonInfo 12 }
 | 
						|
      
 | 
						|
	entRTSThreshold OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER (0..2347)
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"This attribute shall indicate the number of octets in an MPDU, 
 | 
						|
			below which an RTS/CTS handshake shall not be performed."			
 | 
						|
	::= { entWlanCommonInfo 13 }
 | 
						|
      
 | 
						|
	entChannelBandwidth OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER (0..1)
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"This attribute specifies the channel bandwidth: 0(Auto 20/40 MHZ), 1(20 MHZ)"			
 | 
						|
	::= { entWlanCommonInfo 14 }
 | 
						|
    
 | 
						|
	entPreambleType OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER
 | 
						|
        {        
 | 
						|
        	short(1),
 | 
						|
			long(2)
 | 
						|
		}
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"This attribute specifies the preamble type: 1(Short), 2(Long)"			
 | 
						|
	::= { entWlanCommonInfo 15 }
 | 
						|
	
 | 
						|
	entCTSProtection OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER
 | 
						|
		{
 | 
						|
			auto(0),
 | 
						|
			always(1),
 | 
						|
			none(2)
 | 
						|
		}
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"This attribute specifies the CTS protection: 0(Auto), 1(Always), 2(None)"			
 | 
						|
	::= { entWlanCommonInfo 16 }
 | 
						|
	                
 | 
						|
	entWlanESSIDInfoTable       OBJECT-TYPE
 | 
						|
	    SYNTAX          SEQUENCE OF EntWlanESSIDInfoEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "This table provides one row for each ESSID information.
 | 
						|
	        Each row contains the enterprise ESSID information Table
 | 
						|
	         for that ESSID information."
 | 
						|
	::= { entRalinkWlan 2 }
 | 
						|
	  
 | 
						|
	entWlanESSIDInfoEntry       OBJECT-TYPE
 | 
						|
	    SYNTAX          EntWlanESSIDInfoEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION     "An entry in the entWlanESSIDInfoTable."
 | 
						|
	    INDEX           { entWlanESSIDInfoIndex }
 | 
						|
	::= { entWlanESSIDInfoTable 1 }
 | 
						|
                      
 | 
						|
 	EntWlanESSIDInfoEntry ::=
 | 
						|
	  SEQUENCE {
 | 
						|
	  entWlanESSIDInfoIndex		INTEGER,
 | 
						|
	  entESSID				OCTET STRING,
 | 
						|
	  entBroadcastESSID		TruthValue,
 | 
						|
	  entWMM				TruthValue,
 | 
						|
	  entEncryption			INTEGER,
 | 
						|
	  entWlanAuthenticationType	INTEGER
 | 
						|
	 }
 | 
						|
 | 
						|
 	entWlanESSIDInfoIndex OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER
 | 
						|
	   	MAX-ACCESS  read-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "The auxiliary variable used to identify instances of columnar 
 | 
						|
	        objects in the ESSID information Table"
 | 
						|
	::= { entWlanESSIDInfoEntry 1 }  
 | 
						|
	   
 | 
						|
 	entESSID OBJECT-TYPE
 | 
						|
	    SYNTAX      OCTET STRING (SIZE (0..32))
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "This attribute reflects the Service Set ID used in 
 | 
						|
		    the Desired- SSID parameter of the most recent MLME_Scan.request"
 | 
						|
	::= { entWlanESSIDInfoEntry 2 } 
 | 
						|
 | 
						|
	entBroadcastESSID OBJECT-TYPE
 | 
						|
		SYNTAX TruthValue
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Set this attribute TUUE will enable the hidden SSID"			
 | 
						|
	::= { entWlanESSIDInfoEntry 3 }
 | 
						|
	
 | 
						|
	entWMM OBJECT-TYPE
 | 
						|
		SYNTAX TruthValue
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Set this attribute TUUE will enable WMM"			
 | 
						|
	::= { entWlanESSIDInfoEntry 4 }
 | 
						|
	   
 | 
						|
	
 | 
						|
 	entEncryption OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER (0..4)
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "The WLAN encryption: 0(none), 1(WEP), 2(TKIP), 3(AES), 4(TKIPAES)"
 | 
						|
	::= { entWlanESSIDInfoEntry 5 }
 | 
						|
	       
 | 
						|
 	entWlanAuthenticationType OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER (0..8)
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "The current authentication algorithms: 0 (openSystem), 1(wepAuto), 
 | 
						|
	        2(sharedKey), 3(WPAPSK), 4(WPA), 5(WPA2PSK), 6(WPA2), 7(WPA1WPA2),
 | 
						|
	        8(WPA1PSKWPA2PSK)"
 | 
						|
	::= { entWlanESSIDInfoEntry 6 }
 | 
						|
	                           
 | 
						|
	entWlanWepInfoTable			OBJECT-TYPE
 | 
						|
	    SYNTAX          SEQUENCE OF EntWlanWepInfoEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "This table provides one row for each WEP information.
 | 
						|
	        Each row contains the enterprise WEP information Table
 | 
						|
	         for that WEP information."
 | 
						|
	::= { entRalinkWlan 3 }
 | 
						|
	  
 | 
						|
	entWlanWepInfoEntry       OBJECT-TYPE
 | 
						|
	    SYNTAX          EntWlanWepInfoEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION     "An entry in the entWlanWepInfoTable."
 | 
						|
	    INDEX           { entWlanESSIDIndex }
 | 
						|
	::= { entWlanWepInfoTable 1 }
 | 
						|
                      
 | 
						|
 	EntWlanWepInfoEntry ::=
 | 
						|
	  SEQUENCE {
 | 
						|
	  	entWlanESSIDIndex		INTEGER,
 | 
						|
	  	entWlanWepKeyID 		INTEGER,
 | 
						|
		entWlanWepKey1Value     OCTET STRING,
 | 
						|
		entWlanWepKey2Value     OCTET STRING,
 | 
						|
		entWlanWepKey3Value     OCTET STRING,
 | 
						|
		entWlanWepKey4Value     OCTET STRING
 | 
						|
	  }  
 | 
						|
           
 | 
						|
 	entWlanESSIDIndex OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER
 | 
						|
	   	MAX-ACCESS  read-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "The auxiliary variable used to identify instances of columnar 
 | 
						|
	        objects in the WEP information Table"
 | 
						|
	::= { entWlanWepInfoEntry 1 }  
 | 
						|
		                  	 
 | 
						|
 	entWlanWepKeyID OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER (1..4)
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "This attribute shall indicate the use of the first, second, third, or fourth 
 | 
						|
	        element of the WEPDefaultKeys array"
 | 
						|
	::= { entWlanWepInfoEntry 2 }
 | 
						|
 | 
						|
 	entWlanWepKey1Value OBJECT-TYPE
 | 
						|
	    SYNTAX      OCTET STRING
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Set key1 string. (5 or 13 ASCCI characters, 10 or 26 hex numbers)"
 | 
						|
	::= { entWlanWepInfoEntry 3 }
 | 
						|
	
 | 
						|
 	entWlanWepKey2Value OBJECT-TYPE
 | 
						|
	    SYNTAX      OCTET STRING
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Set key2 string. (5 or 13 ASCCI characters, 10 or 26 hex numbers)"
 | 
						|
	::= { entWlanWepInfoEntry 4 } 
 | 
						|
 
 | 
						|
 	entWlanWepKey3Value OBJECT-TYPE
 | 
						|
	    SYNTAX      OCTET STRING
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Set key3 string. (5 or 13 ASCCI characters, 10 or 26 hex numbers)"
 | 
						|
	::= { entWlanWepInfoEntry 5 } 
 | 
						|
 | 
						|
 	entWlanWepKey4Value OBJECT-TYPE
 | 
						|
	    SYNTAX      OCTET STRING
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Set key4 string. (5 or 13 ASCCI characters, 10 or 26 hex numbers)"
 | 
						|
	::= { entWlanWepInfoEntry 6 } 
 | 
						|
 | 
						|
	entWlanWPAInfoTable			OBJECT-TYPE
 | 
						|
	    SYNTAX          SEQUENCE OF EntWlanWPAInfoEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "This table provides one row for each WPA information.
 | 
						|
	        Each row contains the enterprise WPA information Table
 | 
						|
	         for that WPA information."
 | 
						|
	::= { entRalinkWlan 4 }
 | 
						|
	  
 | 
						|
	entWlanWPAInfoEntry       OBJECT-TYPE
 | 
						|
	    SYNTAX          EntWlanWPAInfoEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION     "An entry in the entWlanWPAInfoTable."
 | 
						|
	    INDEX           { entWlanESSIDIndex }
 | 
						|
	::= { entWlanWPAInfoTable 1 }
 | 
						|
                      
 | 
						|
 	EntWlanWPAInfoEntry ::=
 | 
						|
	  SEQUENCE {
 | 
						|
	  entWlanESSIDIndex		INTEGER,
 | 
						|
	  entPresharedKey  	DisplayString
 | 
						|
	 }  
 | 
						|
           
 | 
						|
 	entWlanESSIDIndex OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER
 | 
						|
	   	MAX-ACCESS  read-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "The auxiliary variable used to identify instances of columnar 
 | 
						|
	        objects in the WPA information Table"
 | 
						|
	::= { entWlanWPAInfoEntry 1 }  
 | 
						|
		   	
 | 
						|
 	entPresharedKey OBJECT-TYPE
 | 
						|
	    SYNTAX      DisplayString
 | 
						|
	   	MAX-ACCESS  write-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "The WPA Pre-Shared key. (8~63 ASCII or 64 HEX)"
 | 
						|
	::= { entWlanWPAInfoEntry 2 }
 | 
						|
         
 | 
						|
	ent802dot1xInfoTable			OBJECT-TYPE
 | 
						|
	    SYNTAX          SEQUENCE OF Ent802dot1xInfoEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "This table provides one row for each 802.1x information.
 | 
						|
	        Each row contains the enterprise 802.1x information Table
 | 
						|
	         for that 802.1x information."
 | 
						|
	::= { entRalinkWlan 5 }
 | 
						|
	  
 | 
						|
	ent802dot1xInfoEntry       OBJECT-TYPE
 | 
						|
	    SYNTAX          Ent802dot1xInfoEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION     "An entry in the ent802dot1xInfoTable."
 | 
						|
	    INDEX           { entWlanESSIDIndex }
 | 
						|
	::= { ent802dot1xInfoTable 1 }
 | 
						|
                      
 | 
						|
 	Ent802dot1xInfoEntry ::=
 | 
						|
	  SEQUENCE {
 | 
						|
	  	entWlanESSIDIndex		INTEGER,
 | 
						|
		entRADIUSServerIPAddress  IpAddress,
 | 
						|
		entRADIUSServerPort		INTEGER,
 | 
						|
		entRADIUSServerPassword	DisplayString,
 | 
						|
		entWlan802dot1xEnable TruthValue		
 | 
						|
	  }  
 | 
						|
           
 | 
						|
 	entWlanESSIDIndex OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER
 | 
						|
	   	MAX-ACCESS  read-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "The auxiliary variable used to identify instances of columnar 
 | 
						|
	        objects in the 802.1x information Table"
 | 
						|
	::= { ent802dot1xInfoEntry 1 }
 | 
						|
	
 | 
						|
 	entRADIUSServerIPAddress OBJECT-TYPE
 | 
						|
	    SYNTAX      IpAddress
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "The address of RADIUS Server"
 | 
						|
	::= { ent802dot1xInfoEntry 2 }
 | 
						|
    
 | 
						|
 	entRADIUSServerPort OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER (1..65535)
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "The port of RADIUS Server"
 | 
						|
	::= { ent802dot1xInfoEntry 3 }
 | 
						|
                
 | 
						|
 	entRADIUSServerPassword OBJECT-TYPE
 | 
						|
	    SYNTAX      DisplayString
 | 
						|
	   	MAX-ACCESS  write-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "The password of RADIUS Server"
 | 
						|
	::= { ent802dot1xInfoEntry 4 } 
 | 
						|
	
 | 
						|
 	entWlan802dot1xEnable OBJECT-TYPE
 | 
						|
	    SYNTAX      TruthValue
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Set this attribute TUUE will enable 802.1x"
 | 
						|
	::= { ent802dot1xInfoEntry 5 }
 | 
						|
 | 
						|
-- entSNMP OBJECT IDENTIFIER ::= { eor7550 6 }
 | 
						|
    entSNMPStatus OBJECT-TYPE
 | 
						|
	    SYNTAX TruthValue 
 | 
						|
	    MAX-ACCESS  read-write
 | 
						|
	    STATUS  mandatory
 | 
						|
	    DESCRIPTION
 | 
						|
		    "The status of current SNMP agent.0:disable, 1:Enable"
 | 
						|
	::= { entSNMP 1 }
 | 
						|
 | 
						|
    entSNMPVerType OBJECT-TYPE
 | 
						|
	    SYNTAX INTEGER 
 | 
						|
	    {
 | 
						|
			all(0),
 | 
						|
			v1(1),
 | 
						|
			v2c(2),
 | 
						|
			v3(3)
 | 
						|
		}
 | 
						|
	    MAX-ACCESS  read-write
 | 
						|
	    STATUS  mandatory
 | 
						|
	    DESCRIPTION
 | 
						|
		    "The version of current SNMP agent.0:all, 1: v1, 2:v2c, 3:v3"
 | 
						|
	::= { entSNMP 2 }
 | 
						|
             	  
 | 
						|
	entSNMPCommunityTable       OBJECT-TYPE
 | 
						|
	    SYNTAX          SEQUENCE OF EntSNMPCommunityEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "This table provides one row for each SNMP community.
 | 
						|
	        Each row contains the enterprise SNMP community table
 | 
						|
	         for that SNMP community."
 | 
						|
	::= { entSNMP 3 }
 | 
						|
	  
 | 
						|
	entSNMPCommunityEntry       OBJECT-TYPE
 | 
						|
	    SYNTAX          EntSNMPCommunityEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION     "An entry in the entSNMPCommunityTable."
 | 
						|
	    INDEX           { entSNMPCommunityIndex }
 | 
						|
	::= { entSNMPCommunityTable 1 }
 | 
						|
                      
 | 
						|
 	EntSNMPCommunityEntry ::=
 | 
						|
	  SEQUENCE {
 | 
						|
	  entSNMPCommunityIndex         INTEGER,
 | 
						|
	  entSNMPCommunityName			DisplayString,
 | 
						|
	  entSNMPCommunityType			INTEGER,
 | 
						|
	  entSNMPCommunityValid			TruthValue,
 | 
						|
	  }
 | 
						|
 | 
						|
 	entSNMPCommunityIndex OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER (1..2)
 | 
						|
	   	MAX-ACCESS  read-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "The auxiliary variable used to identify instances of 
 | 
						|
	        columnar objects in the SNMP Community Table"
 | 
						|
	::= { entSNMPCommunityEntry 1 }
 | 
						|
 | 
						|
	entSNMPCommunityName OBJECT-TYPE
 | 
						|
	    SYNTAX      DisplayString (SIZE (0..32))
 | 
						|
	    MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "The community name used to access SNMP device."
 | 
						|
	::= { entSNMPCommunityEntry 2 }
 | 
						|
 
 | 
						|
 	entSNMPCommunityType OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER
 | 
						|
	   	{       
 | 
						|
	   		read(1),
 | 
						|
			write(2)
 | 
						|
		}
 | 
						|
	    MAX-ACCESS  read-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "The auxiliary variable used to identify instances of 
 | 
						|
	        columnar objects in the SNMP Community Table"
 | 
						|
	::= { entSNMPCommunityEntry 3 }
 | 
						|
 | 
						|
 	entSNMPCommunityValid OBJECT-TYPE
 | 
						|
	    SYNTAX      TruthValue
 | 
						|
	    MAX-ACCESS  read-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Display the validity information of corresponding community index"
 | 
						|
	::= { entSNMPCommunityEntry 4 }
 | 
						|
           
 | 
						|
	entSNMPTrap OBJECT IDENTIFIER ::= { entSNMP 4 }
 | 
						|
	                   
 | 
						|
    entTrapStatus OBJECT-TYPE
 | 
						|
	    SYNTAX TruthValue 
 | 
						|
	    MAX-ACCESS  read-write
 | 
						|
	    STATUS  mandatory
 | 
						|
	    DESCRIPTION
 | 
						|
		    "The trap status of current SNMP agent.0:disable, 1:Enable"
 | 
						|
	::= { entSNMPTrap 1 }
 | 
						|
      
 | 
						|
    entTrapVer OBJECT-TYPE
 | 
						|
	    SYNTAX INTEGER 
 | 
						|
	    {
 | 
						|
			all(0),
 | 
						|
			v1(1),
 | 
						|
			v2c(2),
 | 
						|
			v3(3)
 | 
						|
		}
 | 
						|
	    MAX-ACCESS  read-write
 | 
						|
	    STATUS  mandatory
 | 
						|
	    DESCRIPTION
 | 
						|
		    "The trap version of current SNMP agent.0:all, 1: v1, 2:v2c, 3:v3"
 | 
						|
	::= { entSNMPTrap 2 }      
 | 
						|
               
 | 
						|
    entTrapReceiverIPAddress OBJECT-TYPE
 | 
						|
	    SYNTAX IpAddress 
 | 
						|
	    MAX-ACCESS  read-write
 | 
						|
	    STATUS  mandatory
 | 
						|
	    DESCRIPTION
 | 
						|
		    "Specify the IP address(host) to receive the trap report"
 | 
						|
	::= { entSNMPTrap 3 }
 | 
						|
 
 | 
						|
     entTrapReceiverCommunityName OBJECT-TYPE
 | 
						|
	    SYNTAX DisplayString 
 | 
						|
	    MAX-ACCESS  read-write
 | 
						|
	    STATUS  mandatory
 | 
						|
	    DESCRIPTION
 | 
						|
		    "Specify the community name for  SNMP manager to receive the trap report"
 | 
						|
	::= { entSNMPTrap 4 }  
 | 
						|
	        
 | 
						|
 	entTraps OBJECT IDENTIFIER ::= { eor7550 20 }
 | 
						|
	entSystemTraps OBJECT IDENTIFIER ::= { entTraps 1 }
 | 
						|
	entWanTraps	OBJECT IDENTIFIER ::= { entTraps 2 }
 | 
						|
	
 | 
						|
	entSystemTrapsReboot NOTIFICATION-TYPE
 | 
						|
		OBJECTS {}
 | 
						|
		STATUS current
 | 
						|
		DESCRIPTION
 | 
						|
		"The trap is generated when the system is rebooted."
 | 
						|
		::= {entSystemTraps 1}
 | 
						|
		
 | 
						|
	entSystemTrapsRestoreToDefault NOTIFICATION-TYPE
 | 
						|
		OBJECTS {}
 | 
						|
		STATUS current
 | 
						|
		DESCRIPTION
 | 
						|
		"The trap is generated when the default configuration of the system 
 | 
						|
		is restored."
 | 
						|
		::= {entSystemTraps 2}
 | 
						|
 	    
 | 
						|
	entSystemTrapsReloadModules NOTIFICATION-TYPE
 | 
						|
		OBJECTS {}
 | 
						|
		STATUS current
 | 
						|
		DESCRIPTION
 | 
						|
		"The trap is generated when the system modules are reloaded."
 | 
						|
		::= {entSystemTraps 3}
 | 
						|
      
 | 
						|
	entWanTrapsLinkDisconnect NOTIFICATION-TYPE
 | 
						|
		OBJECTS {ifIndex}
 | 
						|
		STATUS current
 | 
						|
		DESCRIPTION
 | 
						|
		"The trap is generated when the PHY of WAN is disconnected and
 | 
						|
		it was connected."
 | 
						|
		::= {entWanTraps 1}
 | 
						|
     
 | 
						|
	entWanTrapsLinkRecover NOTIFICATION-TYPE
 | 
						|
		OBJECTS {ifIndex}
 | 
						|
		STATUS current
 | 
						|
		DESCRIPTION
 | 
						|
		"The trap is generated when the PHY of WAN is connected and
 | 
						|
		it was disconnected"
 | 
						|
		::= {entWanTraps 2}
 | 
						|
 | 
						|
--	entAthWlan OBJECT IDENTIFIER ::= { eor7550 7 }
 | 
						|
--	entAthWlanCommonInfo OBJECT IDENTIFIER ::= { entAthWlan 1}
 | 
						|
       
 | 
						|
	entOpMode OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER
 | 
						|
	   	{       
 | 
						|
			ap(0),
 | 
						|
			client-bridge(1),
 | 
						|
			client-router(2),
 | 
						|
			wds-bridge(3),
 | 
						|
			wds-repeater(4),
 | 
						|
			repeater-ap(5),
 | 
						|
			repeater-sta(6),
 | 
						|
			disable(7)
 | 
						|
		}
 | 
						|
		MAX-ACCESS read-only
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Get op mode: 0(AP), 1(Client bridge), 2(Client router),
 | 
						|
			3(WDS bridge), 4(WDS repeater), 5(Repeater ap), 6(Repeater station),
 | 
						|
			7(Disable)"			
 | 
						|
	::= { entAthWlanCommonInfo 1 }
 | 
						|
                     
 | 
						|
	entBand OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER
 | 
						|
	   	{                 
 | 
						|
	   		ieee802dot11-b-g(0),
 | 
						|
			ieee802dot11-b(1),
 | 
						|
			ieee802dot11-a(2),
 | 
						|
			ieee802dot11-g(4)
 | 
						|
		}
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"The wireless mode: 
 | 
						|
			0(802.11 b/g),
 | 
						|
			1(802.11 b),
 | 
						|
			2(802.11 a),
 | 
						|
			4(802.11 g)"			
 | 
						|
	::= { entAthWlanCommonInfo 4 }
 | 
						|
        
 | 
						|
	entESSIDNum OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER (1..4)
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Only when op mode for Atheros is 0(AP), 
 | 
						|
			set the Number of multiple ESSID"			
 | 
						|
	::= { entAthWlanCommonInfo 5 }
 | 
						|
	          
 | 
						|
	entChannel OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Only when op mode for Atheros is 0(AP), 3(WDS Bridge) and 4(WDS Repeater), 
 | 
						|
			The current operating frequency channel"			
 | 
						|
	::= { entAthWlanCommonInfo 6 }
 | 
						|
 | 
						|
	entDataRate OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER
 | 
						|
        {        
 | 
						|
        	auto(0),
 | 
						|
			oneMbps(1),
 | 
						|
			twoMbps(2),
 | 
						|
			fiveNhalfMbps(5), 
 | 
						|
			elevenMbps(11),
 | 
						|
			sixMbps(6),
 | 
						|
			nineMbps(9),	
 | 
						|
			twelveMbps(12),		
 | 
						|
			eighteenMbps(18),
 | 
						|
			twentytwoMbps(24),
 | 
						|
			thirtysixMbps(36),
 | 
						|
			fortyeightMbps(48),
 | 
						|
			fiftyfourMbps(54)
 | 
						|
		}
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"This attribute specifies the data rate at which the station may transmit data in Mbps
 | 
						|
			0(Auto), 1(1Mbps), 2(2Mbps), 5(5.5Mbps), 11(11Mbps), 6(6Mbps), 9(9Mbps), 12(12Mbps), 
 | 
						|
			18(18Mbps), 24(24Mbps), 36(36Mbps), 48(48Mbps), 54(54Mbps)"			
 | 
						|
	::= { entAthWlanCommonInfo 7 }
 | 
						|
            
 | 
						|
	entTxPower OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Only when op mode for Atheros is 0(AP), 3(WDS Bridge) and 4(WDS Repeater),
 | 
						|
			The transmit power level: 10(%), 25(%), 50(%), 75(%), 90(%), 100(%)"			
 | 
						|
	::= { entAthWlanCommonInfo 9 }
 | 
						|
 | 
						|
	entBeaconInterval OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER (25..1000)
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Only when op mode for Atheros is 0(AP), 3(WDS Bridge) and 4(WDS Repeater),
 | 
						|
			This attribute specifies the number of TU that a station shall use 
 | 
						|
			for scheduling Beacon transmissions"			
 | 
						|
	::= { entAthWlanCommonInfo 10 }
 | 
						|
          
 | 
						|
	entDTIMPeriod OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER (1..255)
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Only when op mode for Atheros is 0(AP), 3(WDS Bridge) and 4(WDS Repeater),
 | 
						|
			This attribute specifies the number of beacon intervals"			
 | 
						|
	::= { entAthWlanCommonInfo 11 }
 | 
						|
              
 | 
						|
	entFragmentationThreshold OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER (256..2346)
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"This attribute shall specify the current maximum size, in octets, 
 | 
						|
			of the MPDU that may be delivered to the PHY"			
 | 
						|
	::= { entAthWlanCommonInfo 12 }
 | 
						|
      
 | 
						|
	entRTSThreshold OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER (0..2347)
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"This attribute shall indicate the number of octets in an MPDU, 
 | 
						|
			below which an RTS/CTS handshake shall not be performed."			
 | 
						|
	::= { entAthWlanCommonInfo 13 }
 | 
						|
    
 | 
						|
	entPreambleType OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER
 | 
						|
        {        
 | 
						|
        	short(1),
 | 
						|
			long(2)
 | 
						|
		}
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"This attribute specifies the preamble type: 1(Short), 2(Long)"			
 | 
						|
	::= { entAthWlanCommonInfo 15 }
 | 
						|
	
 | 
						|
	entCTSProtection OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER
 | 
						|
		{
 | 
						|
			auto(0),
 | 
						|
			always(1),
 | 
						|
			none(2)
 | 
						|
		}
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Only when op mode for Atheros is 0(AP), 3(WDS Bridge) and 4(WDS Repeater),
 | 
						|
			This attribute specifies the CTS protection: 0(Auto), 1(Always), 2(None)"			
 | 
						|
	::= { entAthWlanCommonInfo 16 }
 | 
						|
               
 | 
						|
	entDistance OBJECT-TYPE
 | 
						|
		SYNTAX INTEGER (21..191)
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"ACK timeout"			
 | 
						|
	::= { entAthWlanCommonInfo 17 }
 | 
						|
	
 | 
						|
	entAthWlanESSIDInfoTable       OBJECT-TYPE
 | 
						|
	    SYNTAX          SEQUENCE OF EntAthWlanESSIDInfoEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "This table provides one row for each ESSID information.
 | 
						|
	        Each row contains the enterprise ESSID information Table
 | 
						|
	         for that ESSID information."
 | 
						|
	::= { entAthWlan 2 }
 | 
						|
	  
 | 
						|
	entAthWlanESSIDInfoEntry       OBJECT-TYPE
 | 
						|
	    SYNTAX          EntAthWlanESSIDInfoEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION     "An entry in the entWlanESSIDInfoTable."
 | 
						|
	    INDEX           { entWlanESSIDInfoIndex }
 | 
						|
	::= { entAthWlanESSIDInfoTable 1 }
 | 
						|
                      
 | 
						|
 	EntAthWlanESSIDInfoEntry ::=
 | 
						|
	  SEQUENCE {
 | 
						|
	  entWlanESSIDInfoIndex		INTEGER,
 | 
						|
	  entESSID				OCTET STRING,
 | 
						|
	  entBroadcastESSID		TruthValue,
 | 
						|
	  entWMM				TruthValue,
 | 
						|
	  entEncryption			INTEGER,
 | 
						|
	  entWlanAuthenticationType	INTEGER
 | 
						|
	 }
 | 
						|
 | 
						|
 	entWlanESSIDInfoIndex OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER
 | 
						|
	   	MAX-ACCESS  read-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Only when op mode for Atheros is 0(AP), 3(WDS Bridge) and 4(WDS Repeater),
 | 
						|
	        The auxiliary variable used to identify instances of columnar 
 | 
						|
	        objects in the ESSID information Table"
 | 
						|
	::= { entAthWlanESSIDInfoEntry 1 }  
 | 
						|
	   
 | 
						|
 	entESSID OBJECT-TYPE
 | 
						|
	    SYNTAX      OCTET STRING (SIZE (0..32))
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Only when op mode for Atheros is 0(AP),
 | 
						|
	        This attribute reflects the Service Set ID used in 
 | 
						|
		    the Desired- SSID parameter of the most recent MLME_Scan.request"
 | 
						|
	::= { entAthWlanESSIDInfoEntry 2 } 
 | 
						|
 | 
						|
	entBroadcastESSID OBJECT-TYPE
 | 
						|
		SYNTAX TruthValue
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Only when op mode for Atheros is 0(AP),
 | 
						|
			Set this attribute TUUE will enable the hidden SSID"			
 | 
						|
	::= { entAthWlanESSIDInfoEntry 3 }
 | 
						|
	
 | 
						|
	entWMM OBJECT-TYPE
 | 
						|
		SYNTAX TruthValue
 | 
						|
		MAX-ACCESS read-write
 | 
						|
    	STATUS mandatory
 | 
						|
		DESCRIPTION
 | 
						|
			"Only when op mode for Atheros is 0(AP),
 | 
						|
			Set this attribute TUUE will enable WMM"			
 | 
						|
	::= { entAthWlanESSIDInfoEntry 4 }
 | 
						|
	   
 | 
						|
	
 | 
						|
 	entEncryption OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER (0..4)
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Only when op mode for Atheros is 0(AP), 3(WDS Bridge) and 4(WDS Repeater),
 | 
						|
	        The WLAN encryption: 0(none), 1(WEP), 2(TKIP), 3(AES), 4(TKIPAES)"
 | 
						|
	::= { entAthWlanESSIDInfoEntry 5 }
 | 
						|
	       
 | 
						|
 	entWlanAuthenticationType OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER (0..8)
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Only when op mode for Atheros is 0(AP), 3(WDS Bridge) and 4(WDS Repeater),
 | 
						|
	        The current authentication algorithms: 0 (openSystem), 1(wepAuto), 
 | 
						|
	        2(sharedKey), 3(WPAPSK), 4(WPA), 5(WPA2PSK), 6(WPA2), 7(WPA1WPA2),
 | 
						|
	        8(WPA1PSKWPA2PSK)"
 | 
						|
	::= { entAthWlanESSIDInfoEntry 6 }
 | 
						|
	                           
 | 
						|
	entAthWlanWepInfoTable			OBJECT-TYPE
 | 
						|
	    SYNTAX          SEQUENCE OF EntAthWlanWepInfoEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "This table provides one row for each WEP information.
 | 
						|
	        Each row contains the enterprise WEP information Table
 | 
						|
	         for that WEP information."
 | 
						|
	::= { entAthWlan 3 }
 | 
						|
	  
 | 
						|
	entAthWlanWepInfoEntry       OBJECT-TYPE
 | 
						|
	    SYNTAX          EntAthWlanWepInfoEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION     "An entry in the entWlanWepInfoTable."
 | 
						|
	    INDEX           { entWlanESSIDIndex }
 | 
						|
	::= { entAthWlanWepInfoTable 1 }
 | 
						|
                      
 | 
						|
 	EntAthWlanWepInfoEntry ::=
 | 
						|
	  SEQUENCE {
 | 
						|
	  	entWlanESSIDIndex		INTEGER,
 | 
						|
	  	entWlanWepKeyID 		INTEGER,
 | 
						|
		entWlanWepKey1Value     OCTET STRING,
 | 
						|
		entWlanWepKey2Value     OCTET STRING,
 | 
						|
		entWlanWepKey3Value     OCTET STRING,
 | 
						|
		entWlanWepKey4Value     OCTET STRING
 | 
						|
	  }  
 | 
						|
           
 | 
						|
 	entWlanESSIDIndex OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER
 | 
						|
	   	MAX-ACCESS  read-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Only when op mode for Atheros is 0(AP), 3(WDS Bridge) and 4(WDS Repeater), 
 | 
						|
	        The auxiliary variable used to identify instances of columnar 
 | 
						|
	        objects in the WEP information Table"
 | 
						|
	::= { entAthWlanWepInfoEntry 1 }  
 | 
						|
		                  	 
 | 
						|
 	entWlanWepKeyID OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER (1..4)
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Only when op mode for Atheros is 0(AP), 3(WDS Bridge) and 4(WDS Repeater), 
 | 
						|
	        This attribute shall indicate the use of the first, second, third, or fourth 
 | 
						|
	        element of the WEPDefaultKeys array"
 | 
						|
	::= { entAthWlanWepInfoEntry 2 }
 | 
						|
 | 
						|
 	entWlanWepKey1Value OBJECT-TYPE
 | 
						|
	    SYNTAX      OCTET STRING
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Only when op mode for Atheros is 0(AP), 3(WDS Bridge) and 4(WDS Repeater), 
 | 
						|
	        Set key1 string. (5 or 13 ASCCI characters, 10 or 26 hex numbers)"
 | 
						|
	::= { entAthWlanWepInfoEntry 3 }
 | 
						|
	
 | 
						|
 	entWlanWepKey2Value OBJECT-TYPE
 | 
						|
	    SYNTAX      OCTET STRING
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Only when op mode for Atheros is 0(AP), 3(WDS Bridge) and 4(WDS Repeater), 
 | 
						|
	        Set key2 string. (5 or 13 ASCCI characters, 10 or 26 hex numbers)"
 | 
						|
	::= { entAthWlanWepInfoEntry 4 } 
 | 
						|
 
 | 
						|
 	entWlanWepKey3Value OBJECT-TYPE
 | 
						|
	    SYNTAX      OCTET STRING
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Only when op mode for Atheros is 0(AP), 3(WDS Bridge) and 4(WDS Repeater), 
 | 
						|
	        Set key3 string. (5 or 13 ASCCI characters, 10 or 26 hex numbers)"
 | 
						|
	::= { entAthWlanWepInfoEntry 5 } 
 | 
						|
 | 
						|
 	entWlanWepKey4Value OBJECT-TYPE
 | 
						|
	    SYNTAX      OCTET STRING
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Only when op mode for Atheros is 0(AP), 3(WDS Bridge) and 4(WDS Repeater), 
 | 
						|
	        Set key4 string. (5 or 13 ASCCI characters, 10 or 26 hex numbers)"
 | 
						|
	::= { entAthWlanWepInfoEntry 6 } 
 | 
						|
 | 
						|
	entAthWlanWPAInfoTable			OBJECT-TYPE
 | 
						|
	    SYNTAX          SEQUENCE OF EntAthWlanWPAInfoEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "This table provides one row for each WPA information.
 | 
						|
	        Each row contains the enterprise WPA information Table
 | 
						|
	         for that WPA information."
 | 
						|
	::= { entAthWlan 4 }
 | 
						|
	  
 | 
						|
	entAthWlanWPAInfoEntry       OBJECT-TYPE
 | 
						|
	    SYNTAX          EntAthWlanWPAInfoEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION     "An entry in the entWlanWPAInfoTable."
 | 
						|
	    INDEX           { entWlanESSIDIndex }
 | 
						|
	::= { entAthWlanWPAInfoTable 1 }
 | 
						|
                      
 | 
						|
 	EntAthWlanWPAInfoEntry ::=
 | 
						|
	  SEQUENCE {
 | 
						|
	  entWlanESSIDIndex		INTEGER,
 | 
						|
	  entPresharedKey  	DisplayString
 | 
						|
	 }  
 | 
						|
           
 | 
						|
 	entWlanESSIDIndex OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER
 | 
						|
	   	MAX-ACCESS  read-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Only when op mode for Atheros is 0(AP), 3(WDS Bridge) and 4(WDS Repeater), 
 | 
						|
	        The auxiliary variable used to identify instances of columnar 
 | 
						|
	        objects in the WPA information Table"
 | 
						|
	::= { entAthWlanWPAInfoEntry 1 }  
 | 
						|
		   	
 | 
						|
 	entPresharedKey OBJECT-TYPE
 | 
						|
	    SYNTAX      DisplayString
 | 
						|
	   	MAX-ACCESS  write-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Only when op mode for Atheros is 0(AP), 3(WDS Bridge) and 4(WDS Repeater), 
 | 
						|
	        The WPA Pre-Shared key. (8~63 ASCII or 64 HEX)"
 | 
						|
	::= { entAthWlanWPAInfoEntry 2 }
 | 
						|
         
 | 
						|
	entAth802dot1xInfoTable			OBJECT-TYPE
 | 
						|
	    SYNTAX          SEQUENCE OF EntAth802dot1xInfoEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "This table provides one row for each 802.1x information.
 | 
						|
	        Each row contains the enterprise 802.1x information Table
 | 
						|
	         for that 802.1x information."
 | 
						|
	::= { entAthWlan 5 }
 | 
						|
	  
 | 
						|
	entAth802dot1xInfoEntry       OBJECT-TYPE
 | 
						|
	    SYNTAX          EntAth802dot1xInfoEntry
 | 
						|
	    MAX-ACCESS      not-accessible
 | 
						|
	    STATUS          current
 | 
						|
	    DESCRIPTION     "An entry in the ent802dot1xInfoTable."
 | 
						|
	    INDEX           { entWlanESSIDIndex }
 | 
						|
	::= { entAth802dot1xInfoTable 1 }
 | 
						|
                      
 | 
						|
 	EntAth802dot1xInfoEntry ::=
 | 
						|
	  SEQUENCE {
 | 
						|
	  	entWlanESSIDIndex		INTEGER,
 | 
						|
		entRADIUSServerIPAddress  IpAddress,
 | 
						|
		entRADIUSServerPort		INTEGER,
 | 
						|
		entRADIUSServerPassword	DisplayString,
 | 
						|
		entWlan802dot1xEnable TruthValue		
 | 
						|
	  }  
 | 
						|
           
 | 
						|
 	entWlanESSIDIndex OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER
 | 
						|
	   	MAX-ACCESS  read-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Only when op mode for Atheros is 0(AP), 
 | 
						|
	        The auxiliary variable used to identify instances of columnar 
 | 
						|
	        objects in the 802.1x information Table"
 | 
						|
	::= { entAth802dot1xInfoEntry 1 }
 | 
						|
	
 | 
						|
 	entRADIUSServerIPAddress OBJECT-TYPE
 | 
						|
	    SYNTAX      IpAddress
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Only when op mode for Atheros is 0(AP), 
 | 
						|
	        The address of RADIUS Server"
 | 
						|
	::= { entAth802dot1xInfoEntry 2 }
 | 
						|
    
 | 
						|
 	entRADIUSServerPort OBJECT-TYPE
 | 
						|
	    SYNTAX      INTEGER (1..65535)
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Only when op mode for Atheros is 0(AP), 
 | 
						|
	        The port of RADIUS Server"
 | 
						|
	::= { entAth802dot1xInfoEntry 3 }
 | 
						|
                
 | 
						|
 	entRADIUSServerPassword OBJECT-TYPE
 | 
						|
	    SYNTAX      DisplayString
 | 
						|
	   	MAX-ACCESS  write-only
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Only when op mode for Atheros is 0(AP), 
 | 
						|
	        The password of RADIUS Server"
 | 
						|
	::= { entAth802dot1xInfoEntry 4 } 
 | 
						|
	
 | 
						|
 	entWlan802dot1xEnable OBJECT-TYPE
 | 
						|
	    SYNTAX      TruthValue
 | 
						|
	   	MAX-ACCESS  read-write
 | 
						|
	    STATUS      current
 | 
						|
	    DESCRIPTION
 | 
						|
	        "Only when op mode for Atheros is 0(AP), 
 | 
						|
	        Set this attribute TUUE will enable 802.1x"
 | 
						|
	::= { entAth802dot1xInfoEntry 5 }
 | 
						|
         
 | 
						|
                      
 | 
						|