Tony Murray 11147d3bbf Major Processors rewrite (#8066)
* Extract DiscoveryItem and move some things to better places.
Extract model class
Fix up model construction.  I have problem with construction...
Makeshift model working.  Switch constructor to factory.  discover() and create()
Support legacy discovery.
Remove uneeded custom pollers
Remove netonix custom detection as we try ucd on all os now.
Add a few yaml procs.  Fix a couple things.
More processor discovery conversions
Move Calix e7 to standard hrProcessorLoad, but it doesn't fully implement the HR-MIB, move things around to make it work.
Add a few yaml procs.  Fix a couple things. Correct some stupid mib stuff.
Move more, drop php 5.3
Add netscaler which uses string indexes.  Port fiberhome to yaml and use skip_values
More conversions.  BroadcomProcessorUsage Trait
Serveriron and Ironware share some mibs.  Create a common abstract os for them.
Add yaml support for mib specification in each data entry
Make legacy discover_processor() set 0 for hrDeviceIndex

Untangle Dell switch OS processors

Use use shared OS for groups if they don't have a specific group.
fix silly mib mistake

Make index optional

Move HR and UCD to Traits and out of Processor.

* forgot to update the fortiswitch index

* Make sgos and avaya-ers match the old index.

* fix comware test data

* fix merge errors

* fix dsm and remove pointless empty modules

* file not found exception is in the wrong place.

* Updated processor development docs
2018-02-05 07:39:13 -06:00

51 lines
1.4 KiB
Plaintext

--
-- Title: Switch Base MIB.
--
-- This is specified based on SMIv2, mainly to ensure that the specification
-- can be parsed easily by off-the-shelf network management product in
-- the market.
--
-- The goal of this mib is to access the switch of
-- Brocade's family
-- NOTE: Load BRCD.mib file before loading this mib file.
--
SWBASE-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString, TEXTUAL-CONVENTION
FROM SNMPv2-TC
Counter32, Integer32, IpAddress,
OBJECT-TYPE, OBJECT-IDENTITY,
MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
fcSwitch, bcsiModules
FROM Brocade-REG-MIB;
swMibModule MODULE-IDENTITY
LAST-UPDATED "1104151830Z" -- Apr 15, 20i11 6:30pm
ORGANIZATION "Brocade Communications Systems, Inc.,"
CONTACT-INFO "Customer Support Group
Brocade Communications Systems,
130 Holger Way,
San Jose, CA 95134 U.S.A
Tel: +1-408-333-8000
Fax: +1-408-333-8101
Email: support@Brocade.COM
WEB: www.brocade.com"
DESCRIPTION "The MIB module is for Brocade's Switch.
Copyright (c) 1996-2003 Brocade Communications Systems, Inc.
All rights reserved."
REVISION "1104151830Z" -- Apr 15, 20i11 6:30pm
DESCRIPTION "The initial version of this module."
::= { bcsiModules 3 }
sw OBJECT-IDENTITY
STATUS current
DESCRIPTION "The OID sub-tree for Brocade's Silkworm Series of Switches."
::= { fcSwitch 1 }
END