* Extract DiscoveryItem and move some things to better places. Extract model class Fix up model construction. I have problem with construction... Makeshift model working. Switch constructor to factory. discover() and create() Support legacy discovery. Remove uneeded custom pollers Remove netonix custom detection as we try ucd on all os now. Add a few yaml procs. Fix a couple things. More processor discovery conversions Move Calix e7 to standard hrProcessorLoad, but it doesn't fully implement the HR-MIB, move things around to make it work. Add a few yaml procs. Fix a couple things. Correct some stupid mib stuff. Move more, drop php 5.3 Add netscaler which uses string indexes. Port fiberhome to yaml and use skip_values More conversions. BroadcomProcessorUsage Trait Serveriron and Ironware share some mibs. Create a common abstract os for them. Add yaml support for mib specification in each data entry Make legacy discover_processor() set 0 for hrDeviceIndex Untangle Dell switch OS processors Use use shared OS for groups if they don't have a specific group. fix silly mib mistake Make index optional Move HR and UCD to Traits and out of Processor. * forgot to update the fortiswitch index * Make sgos and avaya-ers match the old index. * fix comware test data * fix merge errors * fix dsm and remove pointless empty modules * file not found exception is in the wrong place. * Updated processor development docs
125 lines
3.2 KiB
Plaintext
125 lines
3.2 KiB
Plaintext
-- This module defines enterprise MIBs for UACs
|
|
--
|
|
-- Copyright (c) 1999-2010, Juniper Networks, Inc.
|
|
-- All rights reserved.
|
|
|
|
NETSCREEN-UAC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
netscreenUAC
|
|
FROM NETSCREEN-SMI
|
|
Integer32, MODULE-IDENTITY, OBJECT-TYPE
|
|
FROM SNMPv2-SMI
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
;
|
|
|
|
netscreenUACMibModule MODULE-IDENTITY
|
|
LAST-UPDATED "201004140000Z" -- Apr 14, 2010
|
|
ORGANIZATION
|
|
"Juniper Networks, Inc."
|
|
CONTACT-INFO
|
|
"Customer Support
|
|
|
|
1194 North Mathilda Avenue
|
|
Sunnyvale, California 94089-1206
|
|
USA
|
|
|
|
Tel: 1-800-638-8296
|
|
E-mail: customerservice@juniper.net
|
|
HTTP://www.juniper.net"
|
|
DESCRIPTION
|
|
"This module defines the object that are used to monitor all
|
|
UAC"
|
|
REVISION "201004140000Z" -- Apr 14, 2010
|
|
DESCRIPTION
|
|
"Creation Date"
|
|
::= { netscreenUAC 0 }
|
|
|
|
|
|
nsUACActiveUsers OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active users on this box, base on auth entry from UAC controler"
|
|
::= { netscreenUAC 1 }
|
|
|
|
|
|
NsUACControlerStatusEntry ::= SEQUENCE
|
|
{
|
|
nsUACControlerId Integer32,
|
|
nsUACControlerName DisplayString,
|
|
nsUACControlerHost DisplayString,
|
|
nsUACConnectionStatus Integer32
|
|
}
|
|
|
|
nsUACControlerStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NsUACControlerStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NetScreen UAC controler status table"
|
|
::= { netscreenUAC 2}
|
|
|
|
nsUACControlerStatusEntry OBJECT-TYPE
|
|
SYNTAX NsUACControlerStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry in the table holds a set of configuration
|
|
parameters associated with an instance of secure UAC."
|
|
INDEX
|
|
{ nsUACControlerID}
|
|
::= { nsUACControlerStatusTable 1 }
|
|
|
|
nsUACControlerId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for UAC table. Its value ranges between 1 and
|
|
65535 and may not be contiguous. the index has no other
|
|
meaning but a pure index"
|
|
::= { nsUACControlerStatusEntry 1 }
|
|
|
|
nsUACControlerName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Secure UAC name."
|
|
::= { nsUACControlerStatusEntry 2 }
|
|
|
|
|
|
nsUACControlerHost OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Secure UAC name."
|
|
::= { nsUACControlerStatusEntry 3 }
|
|
|
|
nsUACConnectionStatus OBJECT-TYPE
|
|
SYNTAX Integer32 {
|
|
disconnected(0),
|
|
connected(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"UAC controler status table"
|
|
::= { nsUACControlerStatusEntry 4 }
|
|
|
|
nsUACGlobalStatus OBJECT-TYPE
|
|
SYNTAX Integer32 {
|
|
disconnected(0),
|
|
connected(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"To indicate whether there is at least one heathy IC-IE connection"
|
|
::= { netscreenUAC 3 }
|
|
END
|