-- SUPERMICRO-SMI.mib:  Super Micro Enterprise Structure of Management Information
 | 
						|
--
 | 
						|
-- October 26 2001, Software LAB
 | 
						|
--
 | 
						|
-- Copyright (c) 1993-2001 by Super Micro Computer Inc.
 | 
						|
-- All rights reserved.
 | 
						|
-- 
 | 
						|
-- *****************************************************************
 | 
						|
 | 
						|
SUPERMICRO-HEALTH-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
IMPORTS
 | 
						|
	MODULE-IDENTITY,
 | 
						|
	OBJECT-TYPE,
 | 
						|
	Integer32,
 | 
						|
	Gauge32
 | 
						|
		FROM SNMPv2-SMI
 | 
						|
	TEXTUAL-CONVENTION,
 | 
						|
	DisplayString,
 | 
						|
	TruthValue
 | 
						|
		FROM SNMPv2-TC
 | 
						|
	MODULE-COMPLIANCE,
 | 
						|
	OBJECT-GROUP
 | 
						|
		FROM SNMPv2-CONF
 | 
						|
	smHealth
 | 
						|
		FROM SUPERMICRO-SMI;
 | 
						|
 | 
						|
smHealthMIB MODULE-IDENTITY
 | 
						|
	LAST-UPDATED "200110260000Z"
 | 
						|
	ORGANIZATION "Super Micro Computer Inc."
 | 
						|
	CONTACT-INFO
 | 
						|
		"	Software Lab
 | 
						|
 | 
						|
		Postal: 980 Rock Avenue
 | 
						|
			San Jose, CA  95131
 | 
						|
			USA
 | 
						|
 | 
						|
		   Tel: +1 408 503 8000
 | 
						|
 | 
						|
		E-mail: SoftLab@supermicro.com"
 | 
						|
	DESCRIPTION
 | 
						|
		"MIB module for monitoring health information"
 | 
						|
	::= { smHealth 1 }
 | 
						|
 | 
						|
SMHealthInfoTypes ::= TEXTUAL-CONVENTION
 | 
						|
	STATUS		current
 | 
						|
	DESCRIPTION
 | 
						|
		"Represents the different types of health information that
 | 
						|
		may be present in a managed device.  The following health
 | 
						|
		information types are currently predefined:
 | 
						|
			0:  fan speed
 | 
						|
			1:  voltage
 | 
						|
			2:  temperature
 | 
						|
		"
 | 
						|
	SYNTAX		Integer32 (0..64)
 | 
						|
 | 
						|
smHealthObjects OBJECT IDENTIFIER ::= { smHealthMIB 1 }
 | 
						|
 | 
						|
smHealthMonitorTable OBJECT-TYPE
 | 
						|
	SYNTAX	    SEQUENCE OF SMHealthMonitorEntry
 | 
						|
	MAX-ACCESS  not-accessible
 | 
						|
	STATUS	    current
 | 
						|
	DESCRIPTION
 | 
						|
		"A table of health monitoring entries."
 | 
						|
	::= { smHealthObjects 1 }
 | 
						|
 | 
						|
-- ================
 | 
						|
smHealthMonitorEntry OBJECT-TYPE
 | 
						|
	SYNTAX	    SMHealthMonitorEntry
 | 
						|
	MAX-ACCESS  not-accessible
 | 
						|
	STATUS	    current
 | 
						|
	DESCRIPTION
 | 
						|
		"An entry in the health monitoring table.
 | 
						|
		Entries cannot be created or deleted via SNMP operations."
 | 
						|
	INDEX	    { smHealthMonitorIndex }
 | 
						|
	::= { smHealthMonitorTable 1 }
 | 
						|
 | 
						|
SMHealthMonitorEntry ::=
 | 
						|
	SEQUENCE {
 | 
						|
		smHealthMonitorIndex		Integer32,
 | 
						|
		smHealthMonitorName			DisplayString,
 | 
						|
		smHealthMonitorType			SMHealthInfoTypes,
 | 
						|
		smHealthMonitorReading		Integer32,
 | 
						|
		smHealthMonitorHighLimit	Integer32,
 | 
						|
		smHealthMonitorLowLimit		Integer32,
 | 
						|
		smHealthMonitorMaxReading	Integer32,
 | 
						|
		smHealthMonitorMinReading	Integer32,
 | 
						|
		smHealthMonitorDivisor		Integer32,
 | 
						|
		smHealthMonitorMonitor		TruthValue
 | 
						|
	}
 | 
						|
 | 
						|
smHealthMonitorIndex OBJECT-TYPE
 | 
						|
	SYNTAX	    Integer32 (1..65535)
 | 
						|
	MAX-ACCESS  not-accessible
 | 
						|
	STATUS	    current
 | 
						|
	DESCRIPTION
 | 
						|
		"The unique value which identifies this Monitor device."
 | 
						|
	::= { smHealthMonitorEntry 1 }
 | 
						|
 | 
						|
smHealthMonitorName OBJECT-TYPE
 | 
						|
	SYNTAX	    DisplayString
 | 
						|
	MAX-ACCESS  read-only
 | 
						|
	STATUS	    current
 | 
						|
	DESCRIPTION
 | 
						|
		"A textual full name assigned to the Monitor device.
 | 
						|
		This object is suitable for output to a human operator."
 | 
						|
	::= { smHealthMonitorEntry 2 }
 | 
						|
 | 
						|
smHealthMonitorType OBJECT-TYPE
 | 
						|
	SYNTAX	    SMHealthInfoTypes
 | 
						|
	MAX-ACCESS  read-only
 | 
						|
	STATUS	    current
 | 
						|
	DESCRIPTION
 | 
						|
		"Identifies this Monitor device type."
 | 
						|
	::= { smHealthMonitorEntry 3 }
 | 
						|
 | 
						|
smHealthMonitorReading OBJECT-TYPE
 | 
						|
	SYNTAX	    Integer32 (0..65535)
 | 
						|
	MAX-ACCESS  read-only
 | 
						|
	STATUS	    current
 | 
						|
	DESCRIPTION
 | 
						|
		"Indicates the value from the Monitor device that are
 | 
						|
		currently in use on the managed device.
 | 
						|
		FAN reading is in unit of RPM,
 | 
						|
		Voltage reading is in unit of mV,
 | 
						|
		Temperture reading is in unit of degree C"
 | 
						|
	::= { smHealthMonitorEntry 4 }
 | 
						|
 | 
						|
smHealthMonitorHighLimit OBJECT-TYPE
 | 
						|
	SYNTAX	    Integer32 (0..65535)
 | 
						|
	MAX-ACCESS  read-write
 | 
						|
	STATUS	    current
 | 
						|
	DESCRIPTION
 | 
						|
		"Indicates the value for the High limitation 
 | 
						|
		for the Monitor device that are currently in use on the
 | 
						|
		managed device.
 | 
						|
		Apply to Temperature and Voltage deivces only.
 | 
						|
		Voltage limit is in unit of mV,
 | 
						|
		Temperture limit is in unit of degree C"
 | 
						|
	::= { smHealthMonitorEntry 5 }
 | 
						|
 | 
						|
smHealthMonitorLowLimit OBJECT-TYPE
 | 
						|
	SYNTAX	    Integer32 (0..65535)
 | 
						|
	MAX-ACCESS  read-write
 | 
						|
	STATUS	    current
 | 
						|
	DESCRIPTION
 | 
						|
		"Indicates the value for the Low limitation 
 | 
						|
		for the Monitor device that are currently in use on the
 | 
						|
		managed device.
 | 
						|
		FAN limit is in unit of RPM,
 | 
						|
		Voltage limit is in unit of mV,
 | 
						|
		Temperture limit is in unit of degree C"
 | 
						|
	::= { smHealthMonitorEntry 6 }
 | 
						|
 | 
						|
smHealthMonitorMaxReading OBJECT-TYPE
 | 
						|
	SYNTAX	    Integer32 (0..65535)
 | 
						|
	MAX-ACCESS  read-only
 | 
						|
	STATUS	    current
 | 
						|
	DESCRIPTION
 | 
						|
		"Indicates the value for the possible Maximum reading value 
 | 
						|
		for the Monitor device that are currently in use on the
 | 
						|
		managed device.
 | 
						|
		FAN reading is in unit of RPM,
 | 
						|
		Voltage reading is in unit of mV,
 | 
						|
		Temperture reading is in unit of degree C"
 | 
						|
	::= { smHealthMonitorEntry 7 }
 | 
						|
 | 
						|
smHealthMonitorMinReading OBJECT-TYPE
 | 
						|
	SYNTAX	    Integer32 (0..65535)
 | 
						|
	MAX-ACCESS  read-only
 | 
						|
	STATUS	    current
 | 
						|
	DESCRIPTION
 | 
						|
		"Indicates the value for the possible Minimum reading value 
 | 
						|
		for the Monitor device that are currently in use on the
 | 
						|
		managed device.
 | 
						|
		FAN reading is in unit of RPM,
 | 
						|
		Voltage reading is in unit of mV,
 | 
						|
		Temperture reading is in unit of degree C"
 | 
						|
	::= { smHealthMonitorEntry 8 }
 | 
						|
 | 
						|
smHealthMonitorDivisor OBJECT-TYPE
 | 
						|
	SYNTAX	    Integer32
 | 
						|
	MAX-ACCESS  read-write
 | 
						|
	STATUS	    current
 | 
						|
	DESCRIPTION
 | 
						|
		"Indicates the value for the Divisor for the Fan
 | 
						|
		device that are currently in use on the managed device.
 | 
						|
		Apply to Fan devices only."
 | 
						|
	::= { smHealthMonitorEntry 9 }
 | 
						|
 | 
						|
smHealthMonitorMonitor OBJECT-TYPE
 | 
						|
	SYNTAX	    TruthValue
 | 
						|
	MAX-ACCESS  read-write
 | 
						|
	STATUS	    current
 | 
						|
	DESCRIPTION
 | 
						|
		"Indicates the monitoring status for the Fan device 
 | 
						|
		that are currently in use on the managed device.
 | 
						|
		1 = monitor, 2=do not monitor"
 | 
						|
	::= { smHealthMonitorEntry 10 }
 | 
						|
                                      
 | 
						|
-- notifications
 | 
						|
 | 
						|
smHealthNotifications OBJECT IDENTIFIER ::= { smHealthMIB 2 }
 | 
						|
 | 
						|
-- (no notifications are currently defined)
 | 
						|
 | 
						|
 | 
						|
-- conformance information
 | 
						|
 | 
						|
smHealthConformance OBJECT IDENTIFIER ::= { smHealthMIB 3 }
 | 
						|
smHealthCompliances OBJECT IDENTIFIER ::= { smHealthConformance 1 }
 | 
						|
smHealthGroups OBJECT IDENTIFIER ::= { smHealthConformance 2 }
 | 
						|
 | 
						|
 | 
						|
-- compliance statements
 | 
						|
 | 
						|
smHealthCompliance MODULE-COMPLIANCE
 | 
						|
	STATUS	current
 | 
						|
	DESCRIPTION
 | 
						|
		"The compliance statement for entities which implement
 | 
						|
		the Supermicro Health Monitoring MIB"
 | 
						|
	MODULE	-- this module
 | 
						|
		MANDATORY-GROUPS { smHealthMonitorGroup}
 | 
						|
	::= { smHealthCompliances 1 }
 | 
						|
 | 
						|
 | 
						|
-- units of conformance
 | 
						|
 | 
						|
smHealthMonitorGroup OBJECT-GROUP
 | 
						|
	OBJECTS {
 | 
						|
		smHealthMonitorType,
 | 
						|
		smHealthMonitorName,
 | 
						|
		smHealthMonitorReading,
 | 
						|
		smHealthMonitorHighLimit,
 | 
						|
		smHealthMonitorLowLimit,
 | 
						|
		smHealthMonitorMaxReading,
 | 
						|
		smHealthMonitorMinReading,
 | 
						|
		smHealthMonitorMonitor
 | 
						|
	}
 | 
						|
	STATUS	current
 | 
						|
	DESCRIPTION
 | 
						|
		"A collection of objects providing Monitor devices."
 | 
						|
	::= { smHealthGroups 1 }
 | 
						|
 | 
						|
END
 |