-- ZyXEL Communications Corporation
 | 
						|
-- Private Enterprise MIB definition
 | 
						|
 | 
						|
-- $Log: zyxel-AS.mib $
 | 
						|
-- Revision 1.2  2006/06/08 09:18:11  niceguy
 | 
						|
-- Revision 1.1  2005/11/23 12:47:58  niceguy
 | 
						|
-- Initial revision
 | 
						|
-- Revision 1.1  2005/08/18 13:30:38  Jeff
 | 
						|
-- Initial revision
 | 
						|
-- Revision 1.12  2004/06/08 10:12:38  jenny
 | 
						|
-- Revision 1.11  2004/05/05 08:33:35  jennyhsu
 | 
						|
-- Revision 1.10  2004/01/29 03:41:26  jennyhsu
 | 
						|
-- Define DHCP option 82 setting
 | 
						|
-- Revision 1.9  2003/09/19 04:57:58  jennyhsu
 | 
						|
-- Add thermalSensorFailure trap. Change the syntax of 
 | 
						|
-- asDhcpRelayOption82Info to be DisplayString
 | 
						|
-- Revision 1.8  2003/09/10 12:26:16  jennyhsu
 | 
						|
-- add DHCP setup
 | 
						|
-- Revision 1.7  2003/06/06 09:15:18  jennyhsu
 | 
						|
-- Revise the descriptions of accessSwitchDSLConfTarget
 | 
						|
-- Revision 1.6  2003/06/06 01:39:28  jennyhsu
 | 
						|
-- Add objects for DSL configuration in batch mode
 | 
						|
-- Revision 1.5  2003/05/27 08:12:45  jennyhsu
 | 
						|
-- Add asPacketForwardingTable
 | 
						|
-- Revision 1.4  2003/03/21 06:57:38  jennyhsu
 | 
						|
-- remove the mask of accessSwitchSystemTemperature
 | 
						|
-- Revision 1.3  2002/12/03 07:49:00  jennyhsu
 | 
						|
-- Add accessSwitchSystemCurrentStatus into the variable binding of 
 | 
						|
-- temp, fan and voltage trap
 | 
						|
-- Revision 1.2  2002/11/12 07:48:00  jennyhsu
 | 
						|
-- Revision 1.1  2002/11/12 07:40:49  jennyhsu
 | 
						|
-- Initial revision
 | 
						|
 | 
						|
 | 
						|
ZYXEL-AS-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
    IMPORTS
 | 
						|
	enterprises, IpAddress	FROM RFC1155-SMI
 | 
						|
	OBJECT-TYPE 		FROM RFC-1212	
 | 
						|
	DisplayString, ifIndex, PhysAddress
 | 
						|
				FROM RFC1213-MIB	  	
 | 
						|
	TRAP-TYPE 		FROM RFC-1215
 | 
						|
	PortList		FROM Q-BRIDGE-MIB
 | 
						|
	RowStatus		FROM SNMPv2-TC
 | 
						|
	MacAddress, Timeout, BridgeId
 | 
						|
				FROM BRIDGE-MIB;
 | 
						|
	
 | 
						|
 | 
						|
	zyxel			OBJECT IDENTIFIER ::= { enterprises 890 }
 | 
						|
	products		OBJECT IDENTIFIER ::= { zyxel 1 }
 | 
						|
	accessSwitch  		OBJECT IDENTIFIER ::= { products 5 }
 | 
						|
	
 | 
						|
	-- accessSwitch generic managed objects
 | 
						|
	accessSwitchCommon	OBJECT IDENTIFIER ::= { accessSwitch 1 }
 | 
						|
	accessSwitchMgnt	OBJECT IDENTIFIER ::= { accessSwitchCommon 1 }
 | 
						|
	
 | 
						|
	accessSwitchStats  	OBJECT IDENTIFIER ::= { accessSwitchCommon 2 }
 | 
						|
	asMacStats    		OBJECT IDENTIFIER ::= { accessSwitchStats 1 }
 | 
						|
	
 | 
						|
	-- accessSwitchMgnt subtree
 | 
						|
	
 | 
						|
	-- System Status	
 | 
						|
	accessSwitchSystemCurrentStatus OBJECT-TYPE
 | 
						|
    	SYNTAX  INTEGER(0..255)
 | 
						|
    	ACCESS  read-only
 | 
						|
    	STATUS  mandatory
 | 
						|
    	DESCRIPTION "This variable indicates the status of the system.
 | 
						|
       		     The sysCurrentStatus is a bit map represented
 | 
						|
       		     as a sum, therefore, it can represent multiple defects
 | 
						|
       		     simultaneously. The sysNoDefect should be set if and only if
 | 
						|
       		     no other flag is set.
 | 
						|
 | 
						|
       		     The various bit positions are:
 | 
						|
                     1   sysNoDefect
 | 
						|
             	     2   sysOverHeat
 | 
						|
		     3	 sysFanRpmLow
 | 
						|
		     4	 sysVoltageLow
 | 
						|
		     5   sysThermalSensorFailure"
 | 
						|
     	::= { accessSwitchMgnt 1 }
 | 
						|
	
 | 
						|
	-- System traps related managed objects
 | 
						|
	
 | 
						|
	accessSwitchProblemCause	OBJECT-TYPE
 | 
						|
        SYNTAX	DisplayString 
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
               		"The variable is the description of sytsem problem."
 | 
						|
     	::= { accessSwitchMgnt 2 }
 | 
						|
     	
 | 
						|
     	-- For AES-100, IES-1000 (SAM1008, AAM1008) only
 | 
						|
 	accessSwitchSystemTemperature	OBJECT-TYPE
 | 
						|
        SYNTAX	DisplayString 
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
              		"The variable is the current temperature in Celsius of the system."
 | 
						|
     	::= { accessSwitchMgnt 3 }
 | 
						|
 | 
						|
 | 
						|
	-- Fan rpm table
 | 
						|
 | 
						|
        accessSwitchFanRpmTable OBJECT-TYPE
 | 
						|
        SYNTAX  SEQUENCE OF AccessSwitchFanRpmEntry
 | 
						|
        ACCESS  not-accessible
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"A table that contains rpm information about the fans."
 | 
						|
        ::= { accessSwitchMgnt 4 }
 | 
						|
 | 
						|
        accessSwitchFanRpmEntry OBJECT-TYPE
 | 
						|
        SYNTAX  AccessSwitchFanRpmEntry
 | 
						|
        ACCESS  not-accessible
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
        		"A list of rpm information for each fan."
 | 
						|
        INDEX  { accessSwitchFanRpmIndex }
 | 
						|
        ::= { accessSwitchFanRpmTable 1 }
 | 
						|
 | 
						|
        AccessSwitchFanRpmEntry ::=
 | 
						|
           SEQUENCE {
 | 
						|
        	accessSwitchFanRpmIndex		INTEGER,
 | 
						|
		accessSwitchFanRpmCurValue	INTEGER,
 | 
						|
		accessSwitchFanRpmMaxValue	INTEGER,
 | 
						|
		accessSwitchFanRpmMinValue	INTEGER,
 | 
						|
		accessSwitchFanRpmLowThresh	INTEGER,
 | 
						|
		accessSwitchFanRpmDescr		DisplayString
 | 
						|
           }
 | 
						|
 | 
						|
        accessSwitchFanRpmIndex OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The identity of the fan."
 | 
						|
        ::= { accessSwitchFanRpmEntry 1 }
 | 
						|
 | 
						|
        accessSwitchFanRpmCurValue OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The current rpm of the fan."
 | 
						|
        ::= { accessSwitchFanRpmEntry 2 }
 | 
						|
 | 
						|
        accessSwitchFanRpmMaxValue OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The maximum rpm ever performed by the fan."
 | 
						|
        ::= { accessSwitchFanRpmEntry 3 }
 | 
						|
 | 
						|
        accessSwitchFanRpmMinValue OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The minimum rpm ever performed by the fan."
 | 
						|
        ::= { accessSwitchFanRpmEntry 4 }
 | 
						|
 | 
						|
        accessSwitchFanRpmLowThresh OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The low threshold of the rpm of the fan. If the current rpm is less than
 | 
						|
			the threshold, the device will initiate the fanRpmLow trap."
 | 
						|
        ::= { accessSwitchFanRpmEntry 5 }
 | 
						|
 | 
						|
        accessSwitchFanRpmDescr OBJECT-TYPE
 | 
						|
        SYNTAX  DisplayString
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The description of the fan (e.g. location, function, etc.)."
 | 
						|
        ::= { accessSwitchFanRpmEntry 6 }
 | 
						|
 | 
						|
 | 
						|
	-- Voltage table
 | 
						|
 | 
						|
        accessSwitchVoltageTable OBJECT-TYPE
 | 
						|
        SYNTAX  SEQUENCE OF AccessSwitchVoltageEntry
 | 
						|
        ACCESS  not-accessible
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"A table that contains voltage information about the system."
 | 
						|
        ::= { accessSwitchMgnt 5 }
 | 
						|
 | 
						|
        accessSwitchVoltageEntry OBJECT-TYPE
 | 
						|
        SYNTAX  AccessSwitchVoltageEntry
 | 
						|
        ACCESS  not-accessible
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
        		"A list of voltage information for each sensor."
 | 
						|
        INDEX  { accessSwitchVoltageIndex }
 | 
						|
        ::= { accessSwitchVoltageTable 1 }
 | 
						|
 | 
						|
        AccessSwitchVoltageEntry ::=
 | 
						|
           SEQUENCE {
 | 
						|
        	accessSwitchVoltageIndex		INTEGER,
 | 
						|
		accessSwitchVoltageCurValue		INTEGER,
 | 
						|
		accessSwitchVoltageMaxValue		INTEGER,
 | 
						|
		accessSwitchVoltageMinValue		INTEGER,
 | 
						|
		accessSwitchVoltageNominalValue		INTEGER,
 | 
						|
		accessSwitchVoltageLowThresh		INTEGER,
 | 
						|
		accessSwitchVoltageDescr		DisplayString
 | 
						|
           }
 | 
						|
 | 
						|
        accessSwitchVoltageIndex OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The identity of the sensor."
 | 
						|
        ::= { accessSwitchVoltageEntry 1 }
 | 
						|
 | 
						|
        accessSwitchVoltageCurValue OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The current voltage detected by the sensor (in milli-voltage)."
 | 
						|
        ::= { accessSwitchVoltageEntry 2 }
 | 
						|
 | 
						|
        accessSwitchVoltageMaxValue OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The maximum voltage ever detected by the sensor (in milli-voltage)."
 | 
						|
        ::= { accessSwitchVoltageEntry 3 }
 | 
						|
 | 
						|
        accessSwitchVoltageMinValue OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The minimum voltage ever detected by the sensor (in milli-voltage)."
 | 
						|
        ::= { accessSwitchVoltageEntry 4 }
 | 
						|
 | 
						|
        accessSwitchVoltageNominalValue OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The nominal voltage which the power should supply (in milli-voltage)."
 | 
						|
        ::= { accessSwitchVoltageEntry 5 }
 | 
						|
 | 
						|
        accessSwitchVoltageLowThresh OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The low threshold of the voltage. If the current voltage is less than
 | 
						|
			the threshold, the device will initiate the voltageLow trap."
 | 
						|
        ::= { accessSwitchVoltageEntry 6 }
 | 
						|
 | 
						|
        accessSwitchVoltageDescr OBJECT-TYPE
 | 
						|
        SYNTAX  DisplayString
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The description of the voltage (e.g. location, nominal value, etc.)."
 | 
						|
        ::= { accessSwitchVoltageEntry 7 }
 | 
						|
 | 
						|
    
 | 
						|
	-- System temperature table
 | 
						|
 | 
						|
        accessSwitchSysTempTable OBJECT-TYPE
 | 
						|
        SYNTAX  SEQUENCE OF AccessSwitchSysTempEntry
 | 
						|
        ACCESS  not-accessible
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"A table that contains temperature information about system."
 | 
						|
        ::= { accessSwitchMgnt 6 }
 | 
						|
 | 
						|
        accessSwitchSysTempEntry OBJECT-TYPE
 | 
						|
        SYNTAX  AccessSwitchSysTempEntry
 | 
						|
        ACCESS  not-accessible
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
        		"A list of temperature information for each sensor."
 | 
						|
        INDEX  { accessSwitchSysTempIndex }
 | 
						|
        ::= { accessSwitchSysTempTable 1 }
 | 
						|
 | 
						|
        AccessSwitchSysTempEntry ::=
 | 
						|
           SEQUENCE {
 | 
						|
        	accessSwitchSysTempIndex	INTEGER,
 | 
						|
		accessSwitchSysTempCurValue	INTEGER,
 | 
						|
		accessSwitchSysTempMaxValue	INTEGER,
 | 
						|
		accessSwitchSysTempMinValue	INTEGER,
 | 
						|
		accessSwitchSysTempHighThresh	INTEGER,
 | 
						|
		accessSwitchSysTempDescr	DisplayString
 | 
						|
           }
 | 
						|
 | 
						|
        accessSwitchSysTempIndex OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The identity of the sensor."
 | 
						|
        ::= { accessSwitchSysTempEntry 1 }
 | 
						|
 | 
						|
        accessSwitchSysTempCurValue OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The current temperature detected in Celsius by the sensor."
 | 
						|
        ::= { accessSwitchSysTempEntry 2 }
 | 
						|
 | 
						|
        accessSwitchSysTempMaxValue OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The maximum temperature ever detected in Celsius by the sensor."
 | 
						|
        ::= { accessSwitchSysTempEntry 3 }
 | 
						|
 | 
						|
        accessSwitchSysTempMinValue OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The minimum temperature ever detected in Celsius by the sensor."
 | 
						|
        ::= { accessSwitchSysTempEntry 4 }
 | 
						|
 | 
						|
        accessSwitchSysTempHighThresh OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The high threshold of the temperature in Celsius. If the current temperature
 | 
						|
			is higher than the threshold, the device will initiate the overheat trap."
 | 
						|
        ::= { accessSwitchSysTempEntry 5 }
 | 
						|
 | 
						|
        accessSwitchSysTempDescr OBJECT-TYPE
 | 
						|
        SYNTAX  DisplayString
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The description of the temperature sensor (e.g. location, function, etc.)."
 | 
						|
 | 
						|
        ::= { accessSwitchSysTempEntry 6 }
 | 
						|
 | 
						|
        accessSwitchMaintenance OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-write
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The managed object is for system maintenance. When the EMS
 | 
						|
                      	 wants to trigger the system maitenance operation, the EMS
 | 
						|
                      	 shall send SNMP-SET message to set the corresponding bit value 
 | 
						|
                      	 to be 1. The various bit positions are:
 | 
						|
                      	 BIT 1: config save
 | 
						|
                      	 BIT 2: reset
 | 
						|
			 BIT 3: local loopback test
 | 
						|
			 BIT 4: remote loopback test"
 | 
						|
        ::= { accessSwitchMgnt 7 }
 | 
						|
 | 
						|
        accessSwitchMaintenancePort OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-write
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The port which the maintenance operation should be performed on.
 | 
						|
			 The value of 0 means the maintenance should be performed on the system."
 | 
						|
        ::= { accessSwitchMgnt 8 }
 | 
						|
 | 
						|
        accessSwitchMaxNumOfStaticVlans OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The maximum number of static VLANs which the system supports"
 | 
						|
        ::= { accessSwitchMgnt 9 }
 | 
						|
 
 | 
						|
-- Chassis information
 | 
						|
        
 | 
						|
        ASSlotNum ::= INTEGER {
 | 
						|
		slot1(1),
 | 
						|
		slot2(2)
 | 
						|
	}
 | 
						|
		
 | 
						|
	ASModuleType ::= INTEGER {
 | 
						|
		aes-100(1),
 | 
						|
		aes-100-1(2),
 | 
						|
		aam1008-61(3),
 | 
						|
		aam1008-63(4), 
 | 
						|
		sam1008(5)
 | 
						|
	}
 | 
						|
	
 | 
						|
		
 | 
						|
	acccessSwitchChassisId OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-write
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The chassis Id of the module"
 | 
						|
        ::= { accessSwitchMgnt 10 }
 | 
						|
        
 | 
						|
        accessSwitchSlotId OBJECT-TYPE
 | 
						|
        SYNTAX  ASSlotNum
 | 
						|
        ACCESS  read-write
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The slot Id of the module"
 | 
						|
        ::= { accessSwitchMgnt 11 }
 | 
						|
        
 | 
						|
        accessSwitchModuleType OBJECT-TYPE
 | 
						|
        SYNTAX  ASModuleType
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The type of the module"
 | 
						|
        ::= { accessSwitchMgnt 12 }
 | 
						|
        
 | 
						|
               
 | 
						|
        accessSwitchFWVersion OBJECT-TYPE
 | 
						|
        SYNTAX  DisplayString
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The firmware version of the access switch."
 | 
						|
        ::= { accessSwitchMgnt 13 }
 | 
						|
        
 | 
						|
        accessSwitchDriverVersion OBJECT-TYPE
 | 
						|
        SYNTAX  DisplayString
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The driver version of the access port in this access switch"
 | 
						|
        ::= { accessSwitchMgnt 14 }
 | 
						|
        
 | 
						|
        accessSwitchModemCodeVersion OBJECT-TYPE
 | 
						|
        SYNTAX  DisplayString
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The modem code version of the access port in this access switch"
 | 
						|
        ::= { accessSwitchMgnt 15 }
 | 
						|
       
 | 
						|
        -- variables for provisioning DSL line in batch mode
 | 
						|
        
 | 
						|
        accessSwitchDSLConfOps OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-write
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The managed object is for xDSL line configuration. When the EMS
 | 
						|
                      	 wants to issue the desired operation, the EMS
 | 
						|
                      	 shall send SNMP-SET message to set the corresponding bit value 
 | 
						|
                      	 to be 1. The various bit positions are:
 | 
						|
                      	 BIT 1: enable port
 | 
						|
                      	 BIT 2: disable port
 | 
						|
			 BIT 3: set DSL mode			 
 | 
						|
			 BIT 4: set profile"
 | 
						|
        ::= { accessSwitchMgnt 16 }
 | 
						|
 | 
						|
        accessSwitchDSLConfTarget OBJECT-TYPE
 | 
						|
        SYNTAX  OCTET STRING
 | 
						|
        ACCESS  read-write
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The managed object is used for identify the target on which 
 | 
						|
			 the line configuration should be performed. The target is encoded 
 | 
						|
		         as:
 | 
						|
		         Byte 1~4: reserved
 | 
						|
		         Byte 5~7: each octet specifies a set of eight ports, with the first
 | 
						|
		                   octet specifying ports 1 through 8, etc.
 | 
						|
		         Byte 8~10: reserved"
 | 
						|
        ::= { accessSwitchMgnt 17 }
 | 
						|
        
 | 
						|
        accessSwitchDSLConfProfileName OBJECT-TYPE
 | 
						|
        SYNTAX  DisplayString (SIZE (1..31))
 | 
						|
        ACCESS  read-write
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The DSL profile name"
 | 
						|
        ::= { accessSwitchMgnt 18 }
 | 
						|
        
 | 
						|
        accessSwitchDSLConfMode OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-write
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The DSL mode. The semantic for each bit is:
 | 
						|
                      	Bit 1: ADSL, G.lite
 | 
						|
                      	Bit 2: ADSL, G.dmt
 | 
						|
                      	Bit 3: ADSL, T1.413
 | 
						|
                      	Bit 4: ADSL, Auto"
 | 
						|
        ::= { accessSwitchMgnt 19 }
 | 
						|
 | 
						|
	-- Packet Forwarding Table
 | 
						|
 | 
						|
        asPacketForwardingTable OBJECT-TYPE
 | 
						|
        SYNTAX	SEQUENCE OF AsPacketForwardingEntry
 | 
						|
        ACCESS  not-accessible
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
        	"This table includes the configuration of packet forwarding."
 | 
						|
        ::= { accessSwitchMgnt 20 }
 | 
						|
 | 
						|
	asPacketForwardingEntry OBJECT-TYPE
 | 
						|
        SYNTAX	AsPacketForwardingEntry
 | 
						|
        ACCESS	not-accessible
 | 
						|
        STATUS	mandatory
 | 
						|
        DESCRIPTION
 | 
						|
		"An entry in asPacketForwardingTable."
 | 
						|
        INDEX   { ifIndex }
 | 
						|
        ::= { asPacketForwardingTable 1 }
 | 
						|
 | 
						|
        AsPacketForwardingEntry ::=
 | 
						|
           SEQUENCE {
 | 
						|
		asPacketForwardingPortList	PortList
 | 
						|
           }
 | 
						|
 | 
						|
        asPacketForwardingPortList    OBJECT-TYPE
 | 
						|
        SYNTAX	PortList
 | 
						|
        ACCESS	read-write
 | 
						|
        STATUS	mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                "The list defines the ports to which the packets
 | 
						|
		will be forwarded."
 | 
						|
         ::= { asPacketForwardingEntry 1 }
 | 
						|
 | 
						|
 | 
						|
	-- DHCP Setup
 | 
						|
 | 
						|
	asDhcpRelayEnable OBJECT-TYPE
 | 
						|
         SYNTAX  INTEGER {
 | 
						|
				enable(1),
 | 
						|
				disable(2)
 | 
						|
			}
 | 
						|
          ACCESS  read-write
 | 
						|
          STATUS  mandatory
 | 
						|
          DESCRIPTION
 | 
						|
                      	"Enable/disable DHCP relay function."
 | 
						|
          ::= { accessSwitchMgnt 21 }
 | 
						|
 | 
						|
         asDhcpRelayOption82Enable OBJECT-TYPE
 | 
						|
          SYNTAX  INTEGER {
 | 
						|
				enable(1),
 | 
						|
				disable(2)
 | 
						|
			}
 | 
						|
          ACCESS  read-write
 | 
						|
          STATUS  mandatory
 | 
						|
          DESCRIPTION
 | 
						|
                        	"Enable/disable the relay agent information option."
 | 
						|
          ::= { accessSwitchMgnt 22 }
 | 
						|
 | 
						|
         asDhcpRelayOption82Info OBJECT-TYPE
 | 
						|
          SYNTAX  DisplayString
 | 
						|
          ACCESS  read-write
 | 
						|
          STATUS  mandatory
 | 
						|
          DESCRIPTION
 | 
						|
                      	"User specific relay agent information."
 | 
						|
          ::= { accessSwitchMgnt 23 }
 | 
						|
 | 
						|
  	asMaxNumOfDhcpServers OBJECT-TYPE
 | 
						|
         SYNTAX  INTEGER
 | 
						|
         ACCESS  read-only
 | 
						|
         STATUS  mandatory
 | 
						|
          DESCRIPTION
 | 
						|
                      	"The maximum number of DHCP servers."
 | 
						|
          ::= { accessSwitchMgnt 24 }
 | 
						|
 | 
						|
	asDhcpServerTable OBJECT-TYPE
 | 
						|
         SYNTAX  SEQUENCE OF AsDhcpServerEntry
 | 
						|
          ACCESS  not-accessible
 | 
						|
          STATUS  mandatory
 | 
						|
         DESCRIPTION
 | 
						|
                "A table that contains DHCP server information."
 | 
						|
          ::= { accessSwitchMgnt 25 }
 | 
						|
 | 
						|
          asDhcpServerEntry OBJECT-TYPE
 | 
						|
          SYNTAX  AsDhcpServerEntry
 | 
						|
          ACCESS  not-accessible
 | 
						|
          STATUS  mandatory
 | 
						|
          DESCRIPTION
 | 
						|
        		"The entry of DHCP server table."
 | 
						|
          INDEX  { asDhcpServerIp }
 | 
						|
          ::= { asDhcpServerTable 1 }
 | 
						|
 | 
						|
          AsDhcpServerEntry ::=
 | 
						|
             SEQUENCE {
 | 
						|
        	asDhcpServerIp		 	IpAddress,
 | 
						|
		asDhcpServerRowStatus		RowStatus
 | 
						|
           }
 | 
						|
	
 | 
						|
	asDhcpServerIp OBJECT-TYPE
 | 
						|
	SYNTAX IpAddress
 | 
						|
	ACCESS	read-only
 | 
						|
	STATUS	mandatory
 | 
						|
	DESCRIPTION
 | 
						|
		"The IP address of the DHCP server."
 | 
						|
	::= { asDhcpServerEntry 1 }
 | 
						|
 | 
						|
	asDhcpServerRowStatus OBJECT-TYPE
 | 
						|
	SYNTAX 	RowStatus
 | 
						|
	ACCESS	read-write
 | 
						|
	STATUS	mandatory
 | 
						|
	DESCRIPTION
 | 
						|
		"The row status of the DHCP server entry."
 | 
						|
	::= { asDhcpServerEntry 2 }
 | 
						|
 | 
						|
 | 
						|
 | 
						|
 | 
						|
	-- SNMP setup, Trap Destination
 | 
						|
	
 | 
						|
--	asMaxNumberOfTrapDestinations OBJECT-TYPE
 | 
						|
--	SYNTAX INTEGER
 | 
						|
--	ACCESS	read-only
 | 
						|
--	STATUS	mandatory
 | 
						|
--	DESCRIPTION
 | 
						|
--		"The max number of the trap destinations."
 | 
						|
--	::= { accessSwitchMgnt 26 }
 | 
						|
--
 | 
						|
--	asSNMPTrapDestTable	OBJECT-TYPE
 | 
						|
-- 	SYNTAX  SEQUENCE OF AsSNMPTrapDestEntry
 | 
						|
--    	ACCESS  not-accessible
 | 
						|
--    	STATUS  mandatory
 | 
						|
--    	DESCRIPTION
 | 
						|
--              "A table that contains SNMP trap destination information."
 | 
						|
--    	::= { accessSwitchMgnt 27 }
 | 
						|
 | 
						|
--    	asSNMPTrapDestEntry OBJECT-TYPE
 | 
						|
--        SYNTAX  AsSNMPTrapDestEntry
 | 
						|
--        ACCESS  not-accessible
 | 
						|
--        STATUS  mandatory
 | 
						|
--        DESCRIPTION
 | 
						|
--        		"The entry of SNMP trap destination table."
 | 
						|
--        INDEX  { asTrapDestIp, asTrapDestPort }
 | 
						|
--        ::= { asSNMPTrapDestTable 1 }
 | 
						|
 | 
						|
--   	AsSNMPTrapDestEntry ::=
 | 
						|
--           SEQUENCE {
 | 
						|
--            asTrapDestIp		 	IpAddress,
 | 
						|
--            asTrapDestPort			INTEGER,
 | 
						|
--	    asTrapDestRowStatus			RowStatus
 | 
						|
--    	   } 
 | 
						|
           	
 | 
						|
--	asTrapDestIp OBJECT-TYPE
 | 
						|
--	SYNTAX IpAddress
 | 
						|
--	ACCESS	read-write
 | 
						|
--	STATUS	mandatory
 | 
						|
--	DESCRIPTION
 | 
						|
--		"The IP address of the trap destination."
 | 
						|
--	::= { asSNMPTrapDestEntry 1 }
 | 
						|
 | 
						|
 | 
						|
--	asTrapDestPort OBJECT-TYPE
 | 
						|
--	SYNTAX INTEGER
 | 
						|
--	ACCESS	read-write
 | 
						|
--	STATUS	mandatory
 | 
						|
--	DESCRIPTION
 | 
						|
--		"The UDP port of the trap destination."
 | 
						|
--	::= { asSNMPTrapDestEntry 2 }
 | 
						|
	
 | 
						|
--	asTrapDestRowStatus OBJECT-TYPE
 | 
						|
--	SYNTAX 	RowStatus
 | 
						|
--	ACCESS	read-write
 | 
						|
--	STATUS	mandatory
 | 
						|
--	DESCRIPTION
 | 
						|
--		"The row status of the trap destination entry."
 | 
						|
--	::= { asSNMPTrapDestEntry 3}
 | 
						|
 | 
						|
 | 
						|
 | 
						|
 | 
						|
         
 | 
						|
-- RADIUS Server setup
 | 
						|
	
 | 
						|
	asMaxNumberOfRadiusServers OBJECT-TYPE
 | 
						|
	SYNTAX INTEGER
 | 
						|
	ACCESS	read-only
 | 
						|
	STATUS	mandatory
 | 
						|
	DESCRIPTION
 | 
						|
		"The max number of the RADIUS Servers."
 | 
						|
	::= { accessSwitchMgnt 28 }
 | 
						|
 | 
						|
	asRadiusServerTable	OBJECT-TYPE
 | 
						|
   	SYNTAX  SEQUENCE OF AsRadiusServerEntry
 | 
						|
    	ACCESS  not-accessible
 | 
						|
    	STATUS  mandatory
 | 
						|
    	DESCRIPTION
 | 
						|
                "A table that contains Radius Server information."
 | 
						|
    	::= { accessSwitchMgnt 29 }
 | 
						|
 | 
						|
    	asRadiusServerEntry OBJECT-TYPE
 | 
						|
        SYNTAX  AsRadiusServerEntry
 | 
						|
        ACCESS  not-accessible
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
        		"The entry of Radius Server table."
 | 
						|
        INDEX  { asRadiusServerIndex }
 | 
						|
        ::= { asRadiusServerTable 1 }
 | 
						|
 | 
						|
   	AsRadiusServerEntry ::=
 | 
						|
           SEQUENCE {
 | 
						|
            asRadiusServerIndex			INTEGER,
 | 
						|
            asRadiusServerIp		 	IpAddress,
 | 
						|
            asRadiusServerPort			INTEGER,
 | 
						|
            asRadiusSharedSecret		DisplayString,
 | 
						|
	    asRadiusServerRowStatus		RowStatus
 | 
						|
    	   } 
 | 
						|
        
 | 
						|
        asRadiusServerIndex OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS  read-only
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                      	"The identity of the RADIUS server."
 | 
						|
        ::= { asRadiusServerEntry 1 }
 | 
						|
        
 | 
						|
	asRadiusServerIp OBJECT-TYPE
 | 
						|
	SYNTAX IpAddress
 | 
						|
	ACCESS	read-write
 | 
						|
	STATUS	mandatory
 | 
						|
	DESCRIPTION
 | 
						|
		"The IP address of the Radius Server."
 | 
						|
	::= { asRadiusServerEntry 2 }
 | 
						|
 | 
						|
 | 
						|
	asRadiusServerPort OBJECT-TYPE
 | 
						|
	SYNTAX INTEGER
 | 
						|
	ACCESS	read-write
 | 
						|
	STATUS	mandatory
 | 
						|
	DESCRIPTION
 | 
						|
		"The UDP port of the Radius Server."
 | 
						|
	::= { asRadiusServerEntry 3 }
 | 
						|
	
 | 
						|
	asRadiusSharedSecret OBJECT-TYPE
 | 
						|
	SYNTAX DisplayString
 | 
						|
	ACCESS	read-write
 | 
						|
	STATUS	mandatory
 | 
						|
	DESCRIPTION
 | 
						|
		"The shared secret of the Radius Server."
 | 
						|
	::= { asRadiusServerEntry 4 }
 | 
						|
	
 | 
						|
	asRadiusServerRowStatus OBJECT-TYPE
 | 
						|
	SYNTAX 	RowStatus
 | 
						|
	ACCESS	read-write
 | 
						|
	STATUS	mandatory
 | 
						|
	DESCRIPTION
 | 
						|
		"The row status of the Radius Server entry."
 | 
						|
	::= { asRadiusServerEntry 5 } 
 | 
						|
         
 | 
						|
         
 | 
						|
         
 | 
						|
         
 | 
						|
-- 802.1x option
 | 
						|
	
 | 
						|
	asDot1xEnable OBJECT-TYPE
 | 
						|
	SYNTAX  INTEGER {
 | 
						|
				enable(1),
 | 
						|
				disable(2)
 | 
						|
			}
 | 
						|
        ACCESS  read-write
 | 
						|
	STATUS	mandatory
 | 
						|
	DESCRIPTION
 | 
						|
		"Enable/disable the 802.1x function."
 | 
						|
	::= { accessSwitchMgnt 30 } 
 | 
						|
         
 | 
						|
         
 | 
						|
 | 
						|
-- 802.1x Table
 | 
						|
 | 
						|
        asDot1xPortTable OBJECT-TYPE
 | 
						|
        SYNTAX	SEQUENCE OF AsDot1xPortEntry
 | 
						|
        ACCESS  not-accessible
 | 
						|
        STATUS  mandatory
 | 
						|
        DESCRIPTION
 | 
						|
        	"This table includes the configuration of 802.1x."
 | 
						|
        ::= { accessSwitchMgnt 31 }
 | 
						|
 | 
						|
	asDot1xPortEntry OBJECT-TYPE
 | 
						|
        SYNTAX	AsDot1xPortEntry
 | 
						|
        ACCESS	not-accessible
 | 
						|
        STATUS	mandatory
 | 
						|
        DESCRIPTION
 | 
						|
		"An entry in asDot1xPortTable."
 | 
						|
        INDEX   { ifIndex }
 | 
						|
        ::= { asDot1xPortTable 1 }
 | 
						|
 | 
						|
        AsDot1xPortEntry ::=
 | 
						|
           SEQUENCE {
 | 
						|
		asDot1xPortEnable	  	INTEGER,
 | 
						|
		asDot1xPortControl	  	INTEGER,
 | 
						|
		asDot1xPortReAuthEnable		INTEGER,
 | 
						|
		asDot1xPortReAuthPeriod		INTEGER
 | 
						|
           }
 | 
						|
 | 
						|
        asDot1xPortEnable    OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER {
 | 
						|
				enable(1),
 | 
						|
				disable(2)
 | 
						|
			}
 | 
						|
        ACCESS	read-write
 | 
						|
        STATUS	mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                "The option defines if the port enables 802.1x
 | 
						|
		settings."
 | 
						|
         ::= { asDot1xPortEntry 1 }
 | 
						|
         
 | 
						|
         asDot1xPortControl    OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER {
 | 
						|
				auto(1),
 | 
						|
				forceAuth(2),
 | 
						|
				forceUnAuth(3)
 | 
						|
			}
 | 
						|
        ACCESS	read-write
 | 
						|
        STATUS	mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                "The configuration defines the 802.1x port control
 | 
						|
		type."
 | 
						|
         ::= { asDot1xPortEntry 2 }
 | 
						|
 | 
						|
	asDot1xPortReAuthEnable    OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER {
 | 
						|
				on(1),
 | 
						|
				off(2)
 | 
						|
			}
 | 
						|
        ACCESS	read-write
 | 
						|
        STATUS	mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                "The option defines if the port enables 802.1x
 | 
						|
		re-authentication."
 | 
						|
         ::= { asDot1xPortEntry 3 }
 | 
						|
         
 | 
						|
        asDot1xPortReAuthPeriod    OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER
 | 
						|
        ACCESS	read-write
 | 
						|
        STATUS	mandatory
 | 
						|
        DESCRIPTION
 | 
						|
                "The configuration defines the 802.1x
 | 
						|
		re-authentication period for each port."
 | 
						|
         ::= { asDot1xPortEntry 4 }
 | 
						|
 
 | 
						|
         
 | 
						|
--------------------
 | 
						|
--  Statistics
 | 
						|
--------------------
 | 
						|
		
 | 
						|
	asMacDisplayTarget OBJECT-TYPE
 | 
						|
	SYNTAX INTEGER
 | 
						|
	MAX-ACCESS read-write
 | 
						|
	STATUS current
 | 
						|
	DESCRIPTION
 | 
						|
		"This managed object is a filter used for identify the target from which 
 | 
						|
		the MAC addresses are learned in macTable. The target should be
 | 
						|
		IfIndex which is used for identifying subscriber ports 
 | 
						|
		(e.g. 300 means all ports in slot 3 and 301 means port 1 in slot 3)."
 | 
						|
	::= { asMacStats 1 }
 | 
						|
 | 
						|
-- macTable
 | 
						|
         
 | 
						|
        asMacTable OBJECT-TYPE
 | 
						|
        SYNTAX SEQUENCE OF AsMacEntry
 | 
						|
        MAX-ACCESS not-accessible
 | 
						|
        STATUS current
 | 
						|
        DESCRIPTION
 | 
						|
        	"A table that contains information about unicast
 | 
						|
                entries for which the bridge has forwarding and/or
 | 
						|
                filtering information. This information is used
 | 
						|
                by the transparent bridging function in
 | 
						|
                determining how to propagate a received frame."
 | 
						|
        ::= { asMacStats 2 }
 | 
						|
 | 
						|
        asMacEntry OBJECT-TYPE
 | 
						|
        SYNTAX AsMacEntry
 | 
						|
        MAX-ACCESS not-accessible
 | 
						|
        STATUS current
 | 
						|
        DESCRIPTION
 | 
						|
        	"An entry of asMacTable."
 | 
						|
        INDEX { asMacAddress }
 | 
						|
        ::= { asMacTable 1 }
 | 
						|
 | 
						|
        AsMacEntry ::=
 | 
						|
        	SEQUENCE {
 | 
						|
                  	asMacAddress	MacAddress,
 | 
						|
                  	asMacPort	INTEGER,
 | 
						|
                  	asMacStatus	INTEGER
 | 
						|
              	}
 | 
						|
 | 
						|
        asMacAddress OBJECT-TYPE
 | 
						|
        SYNTAX MacAddress
 | 
						|
        MAX-ACCESS read-only
 | 
						|
        STATUS current
 | 
						|
        DESCRIPTION
 | 
						|
        	"A unicast MAC address for which the bridge has
 | 
						|
                forwarding and/or filtering information."
 | 
						|
        ::= { asMacEntry 1 }
 | 
						|
 | 
						|
        asMacPort OBJECT-TYPE
 | 
						|
        SYNTAX INTEGER
 | 
						|
        MAX-ACCESS read-only
 | 
						|
        STATUS current
 | 
						|
        DESCRIPTION
 | 
						|
        	"The port from which the mac address has been learned."
 | 
						|
        ::= { asMacEntry 2 }
 | 
						|
 | 
						|
        asMacStatus OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER {
 | 
						|
                          other(1),
 | 
						|
                          invalid(2),
 | 
						|
                          learned(3),
 | 
						|
                          self(4),
 | 
						|
                          mgmt(5)
 | 
						|
        	}
 | 
						|
        MAX-ACCESS read-only
 | 
						|
        STATUS current
 | 
						|
        DESCRIPTION
 | 
						|
        	"The status of this entry."
 | 
						|
	::= { asMacEntry 3 }         
 | 
						|
         
 | 
						|
         
 | 
						|
         
 | 
						|
         
 | 
						|
         
 | 
						|
 | 
						|
   -- accessSwitch specific traps
 | 
						|
   
 | 
						|
 	reboot	TRAP-TYPE
 | 
						|
	ENTERPRISE	accessSwitch
 | 
						|
        VARIABLES       { 
 | 
						|
                        accessSwitchProblemCause
 | 
						|
                        }
 | 
						|
	DESCRIPTION	"Send a message to the manager that the system is going to reboot.
 | 
						|
	                 The variable is the reason why the system reboots."
 | 
						|
	::= 1
 | 
						|
	
 | 
						|
	systemShutdown	TRAP-TYPE
 | 
						|
	ENTERPRISE	accessSwitch
 | 
						|
        VARIABLES       { 
 | 
						|
                        accessSwitchProblemCause 
 | 
						|
                        }
 | 
						|
	DESCRIPTION	"Send a message to the manager that the system is going to shutdown.
 | 
						|
	                 The variable is the reason that causes the system to shutdown."
 | 
						|
	::= 2
 | 
						|
	    
 | 
						|
	overheat	TRAP-TYPE
 | 
						|
	ENTERPRISE	accessSwitch
 | 
						|
        VARIABLES       { 
 | 
						|
                        accessSwitchSysTempIndex,
 | 
						|
                        accessSwitchSysTempCurValue,
 | 
						|
                        accessSwitchSystemCurrentStatus 
 | 
						|
                        }
 | 
						|
	DESCRIPTION	"Send a message to the manager that the system is overheated.
 | 
						|
	                 The variable in the binding list is the current temperature in Celsius 
 | 
						|
	                 of the system."
 | 
						|
	::= 3
 | 
						|
		
 | 
						|
	overheatOver	TRAP-TYPE
 | 
						|
	ENTERPRISE	accessSwitch
 | 
						|
        VARIABLES       { 
 | 
						|
                        accessSwitchSysTempIndex,
 | 
						|
                        accessSwitchSysTempCurValue,
 | 
						|
                        accessSwitchSystemCurrentStatus
 | 
						|
                        }
 | 
						|
	DESCRIPTION	"Send a message to the manager that the overheated condition is over.
 | 
						|
	                 The variable in the binding list is the current temperature in Celsius 
 | 
						|
	                 of the system."
 | 
						|
	::= 4
 | 
						|
 | 
						|
 	errLog		TRAP-TYPE
 | 
						|
	ENTERPRISE	accessSwitch
 | 
						|
        VARIABLES       { 
 | 
						|
                        accessSwitchProblemCause
 | 
						|
                        }
 | 
						|
	DESCRIPTION	"Send a message to the manager that an error log is created in system.
 | 
						|
			The variable in the binding list is the content of the error log."
 | 
						|
	::= 5	
 | 
						|
 | 
						|
	fanRpmLow	TRAP-TYPE
 | 
						|
	ENTERPRISE	accessSwitch
 | 
						|
        VARIABLES       { 
 | 
						|
                        accessSwitchFanRpmIndex,
 | 
						|
                        accessSwitchFanRpmCurValue,
 | 
						|
                        accessSwitchSystemCurrentStatus 
 | 
						|
                        }
 | 
						|
	DESCRIPTION	"Send a message to the manager that the rpm of the fan is too low.
 | 
						|
	                 The variable in the binding list is the current rpm of the fan."
 | 
						|
	::= 6
 | 
						|
		
 | 
						|
	fanRpmNormal	TRAP-TYPE
 | 
						|
	ENTERPRISE	accessSwitch
 | 
						|
        VARIABLES       { 
 | 
						|
                        accessSwitchFanRpmIndex,
 | 
						|
                        accessSwitchFanRpmCurValue,
 | 
						|
                        accessSwitchSystemCurrentStatus
 | 
						|
                        }
 | 
						|
	DESCRIPTION	"Send a message to the manager that the low-rpm condition of the fan is over.
 | 
						|
	                 The variable in the binding list is the current rpm of the fan."
 | 
						|
	::= 7
 | 
						|
 | 
						|
	voltageOutOfRange	TRAP-TYPE
 | 
						|
	ENTERPRISE	accessSwitch
 | 
						|
        VARIABLES       { 
 | 
						|
                        accessSwitchVoltageIndex,
 | 
						|
                        accessSwitchVoltageCurValue,
 | 
						|
                        accessSwitchSystemCurrentStatus
 | 
						|
                        }
 | 
						|
	DESCRIPTION	"Send a message to the manager that the voltage of the system is out of range.
 | 
						|
	                 The variable in the binding list is the current voltage in volt 
 | 
						|
	                 of the system."
 | 
						|
	::= 8
 | 
						|
		
 | 
						|
	voltageNormal	TRAP-TYPE
 | 
						|
	ENTERPRISE	accessSwitch
 | 
						|
        VARIABLES       { 
 | 
						|
                        accessSwitchVoltageIndex,
 | 
						|
                        accessSwitchVoltageCurValue,
 | 
						|
                        accessSwitchSystemCurrentStatus
 | 
						|
                        }
 | 
						|
	DESCRIPTION	"Send a message to the manager that the low-voltage condition is over.
 | 
						|
	                 The variable in the binding list is the current voltage in volt 
 | 
						|
	                 of the system."
 | 
						|
	::= 9
 | 
						|
	
 | 
						|
	systemMaintenanceFailure	TRAP-TYPE
 | 
						|
	ENTERPRISE	accessSwitch
 | 
						|
        VARIABLES       { 
 | 
						|
                        accessSwitchProblemCause
 | 
						|
                        }
 | 
						|
	DESCRIPTION	"Send a message to the manager that the system maintence operation
 | 
						|
	                 fail. The variable in the variable binding indicates the problem."
 | 
						|
	::= 10	
 | 
						|
	
 | 
						|
	configChange	TRAP-TYPE
 | 
						|
	ENTERPRISE	accessSwitch
 | 
						|
        VARIABLES       { 
 | 
						|
                        accessSwitchProblemCause
 | 
						|
                        }
 | 
						|
	DESCRIPTION	"Send a message to the manager that the system configuration 
 | 
						|
			data is changed."
 | 
						|
	::= 11	
 | 
						|
	
 | 
						|
      	thermalSensorFailure TRAP-TYPE
 | 
						|
	ENTERPRISE	accessSwitch
 | 
						|
	VARIABLES	{
 | 
						|
      			accessSwitchProblemCause	
 | 
						|
      			}
 | 
						|
      	DESCRIPTION	"The trap signifies that the thermal sensor failed."
 | 
						|
      	::= 12		
 | 
						|
 | 
						|
END 	 |