Files
librenms-librenms/mibs/ericsson/RBN-TC
Tony Murray 11147d3bbf Major Processors rewrite (#8066)
* Extract DiscoveryItem and move some things to better places.
Extract model class
Fix up model construction.  I have problem with construction...
Makeshift model working.  Switch constructor to factory.  discover() and create()
Support legacy discovery.
Remove uneeded custom pollers
Remove netonix custom detection as we try ucd on all os now.
Add a few yaml procs.  Fix a couple things.
More processor discovery conversions
Move Calix e7 to standard hrProcessorLoad, but it doesn't fully implement the HR-MIB, move things around to make it work.
Add a few yaml procs.  Fix a couple things. Correct some stupid mib stuff.
Move more, drop php 5.3
Add netscaler which uses string indexes.  Port fiberhome to yaml and use skip_values
More conversions.  BroadcomProcessorUsage Trait
Serveriron and Ironware share some mibs.  Create a common abstract os for them.
Add yaml support for mib specification in each data entry
Make legacy discover_processor() set 0 for hrDeviceIndex

Untangle Dell switch OS processors

Use use shared OS for groups if they don't have a specific group.
fix silly mib mistake

Make index optional

Move HR and UCD to Traits and out of Processor.

* forgot to update the fortiswitch index

* Make sgos and avaya-ers match the old index.

* fix comware test data

* fix merge errors

* fix dsm and remove pointless empty modules

* file not found exception is in the wrong place.

* Updated processor development docs
2018-02-05 07:39:13 -06:00

165 lines
5.0 KiB
Plaintext

-- %DNP% $Id: RBN-TC.my,v 1.1.2.8.252.3 2011/02/22 17:26:18 thatcher Exp $
-- %DNP% $Source: /cvsroot/pkt/sw/se/xc/bsd/config/snmp/mibs/Attic/RBN-TC.my,v $
-- *****************************************************************
-- RBN-TC Textual Convention MIB
--
-- Copyright (c) 2000, 2002-2009, 2011 Ericsson AB
-- All rights reserved.
--
-- *****************************************************************
RBN-TC DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
Integer32, Unsigned32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION
FROM SNMPv2-TC
rbnModules
FROM RBN-SMI;
rbnTC MODULE-IDENTITY
LAST-UPDATED "201101191800Z" -- Jan 19, 2011
ORGANIZATION "Ericsson AB."
CONTACT-INFO
" Ericsson AB.
Postal: 100 Headquarters Dr
San Jose, CA 95134
USA
Phone: +1 408 750 5000
Fax: +1 408 750 5599
"
DESCRIPTION
"Defines common textual conventions used in RBN mib
modules."
REVISION "201101191800Z" -- Jan 19, 2011
DESCRIPTION
"Update CONTACT-INFO & ORGANIZATION. "
REVISION "200910201700Z" -- Oct 20, 2009
DESCRIPTION
"Added new textual convention: RbnUnsigned64 for read-write
capable 64 bit integer value."
REVISION "200406191700Z" -- June 19, 2004
DESCRIPTION
"Added new textual convention: RbnPortMediumType. Correct
warnings given by smilint."
REVISION "200303171700Z" -- March 17, 2003
DESCRIPTION
"Added new textual convention: RbnVidOrUntagged."
REVISION "200211110000Z" -- November 11, 2002
DESCRIPTION
"Moved definitions of RbnSlot and RbnPort from RBN-PVC-MIB.
Updated range on RbnSlot and RbnPort."
REVISION "200206260000Z" -- June 26, 2002
DESCRIPTION
"Updated CONTACT-INFO. Added new textual conventions:
RbnKBytes and RbnPercentage."
REVISION "200007140000Z" -- July 14, 2000
DESCRIPTION
"Initial version."
::= { rbnModules 2 }
RbnCircuitHandle ::= TEXTUAL-CONVENTION
DISPLAY-HINT "1d:1d:2x-2x-2x"
STATUS current
DESCRIPTION
"A unique identifier for individual circuits. The string is
composed of the following:
Octet 1 slot
2 port
3-8 circuit identifier
slots/ports are numbered 0..n. The SMS CLI also numbers slots/ports
0..n but SE CLI numbers slots/ports 1..n. For example: When the
SE CLI refers to slot/port 1/2, this maps to to the RbnCircuitHandle
slot/port 0/1
"
SYNTAX OCTET STRING (SIZE (8))
RbnKBytes ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"Storage size, expressed in units of 1024 bytes."
SYNTAX Integer32 (0..2147483647)
RbnPercentage ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d%"
STATUS current
DESCRIPTION
"This Textual Convention describes an object that stores
a whole integer percentage value."
SYNTAX Integer32 (0..100)
RbnSlot ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"The chassis slot number. This is the physical slot
number as reported in the CLI command 'show hardware'
on SMS and the CLI command 'show port' on SE."
SYNTAX Unsigned32 (0..255)
RbnPort ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"The chassis port number. This is the physical port
number as reported in the CLI command 'show hardware'
on SMS and the CLI command 'show port' on SE."
SYNTAX Unsigned32 (0..255)
RbnVidOrUntagged ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"The twelve-bit VLAN Identifer (VID) used to uniquely
identify the VLAN to which the frame belongs. The VID is
encoded as an unsigned binary number. An untagged frame
does not carry any identification of the VLAN to which it
belongs and is designated with a value of 4096."
SYNTAX Integer32 (1..4096)
RbnPortMediumType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Medium type of NAS port."
SYNTAX INTEGER {
unknown(0),
dsl(11),
cable(12),
wireless(13),
satellite(14)
}
RbnUnsigned64 ::= TEXTUAL-CONVENTION
DISPLAY-HINT "8d"
STATUS current
DESCRIPTION
"Unsigned 64 bit integer value is represented as an
OCTET STRING. This allows an unsigned integer value in
the range 0..18446744073709551615.
The octets are ordered with the first octet containing
the highest ordered bits of the integer and the 8th octet
containing the lowest ordered bits, corresponding to
network byte order."
SYNTAX OCTET STRING (SIZE(8))
END