CHASSIS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- ctron-chassis-mib.txt
|
|
-- Revision: 1.07.00
|
|
-- Part Number: 2170548
|
|
-- Date: January 31, 1997
|
|
|
|
-- Cabletron Systems, Inc.
|
|
-- 35 Industrial Way, P.O. Box 5005
|
|
-- Rochester, NH 03867-0505
|
|
-- (603) 332-9400
|
|
-- support@ctron.com
|
|
|
|
-- This module provides authoritative definitions for Cabletron's
|
|
-- enterprise-specific chassis MIB.
|
|
--
|
|
-- This module will be extended, as needed.
|
|
--
|
|
|
|
-- Cabletron Systems reserves the right to make changes in
|
|
-- specification and other information contained in this document
|
|
-- without prior notice. The reader should consult Cabletron Systems
|
|
-- to determine whether any such changes have been made.
|
|
--
|
|
-- In no event shall Cabletron Systems be liable for any incidental,
|
|
-- indirect, special, or consequential damages whatsoever (including
|
|
-- but not limited to lost profits) arising out of or related to this
|
|
-- document or the information contained in it, even if Cabletron
|
|
-- Systems has been advised of, known, or should have known, the
|
|
-- possibility of such damages.
|
|
--
|
|
-- Cabletron grants vendors, end-users, and other interested parties
|
|
-- a non-exclusive license to use this Specification in connection
|
|
-- with the management of Cabletron products.
|
|
|
|
-- Copyright August 95 Cabletron Systems
|
|
|
|
IMPORTS
|
|
NetworkAddress, Counter, TimeTicks
|
|
FROM RFC1155-SMI
|
|
chassis
|
|
FROM CTRON-MIB-NAMES
|
|
DisplayString
|
|
FROM RFC1213-MIB
|
|
OBJECT-TYPE
|
|
FROM RFC-1212;
|
|
|
|
|
|
-- This MIB module uses the extended OBJECT-TYPE macro as defined
|
|
-- RFC 1212
|
|
|
|
-- Textual convention
|
|
|
|
|
|
-- DisplayString ::= OCTET STRING
|
|
-- This data type is used to model textual information taken from
|
|
-- the NVT ASCII character set. By convention, objects with this
|
|
-- syntax, unless explicitly stated, are declared as having:
|
|
--
|
|
-- SIZE (0..255)
|
|
|
|
-- chType is, in generic terms, similar to sysObjectID in
|
|
-- MIB-II. It is defined for the sake of completeness, and
|
|
-- in order to negate dependencies on other MIBs.
|
|
|
|
chType OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Identifies the type of hub-based or standalone device.
|
|
A vendor's authoritative identification of this
|
|
chassis or device. By convention, this value is
|
|
allocated within the SMI enterprises subtree(1.3.6.1.4.1),
|
|
and provides an easy and unambiguous means for
|
|
determining `what kind of box' is being managed. If this
|
|
information is not present or unknown, its value should
|
|
be set to the OBJECT IDENTIFIER { 0 0 }, which is a
|
|
syntactically valid object identifier."
|
|
::= { chassis 1 }
|
|
|
|
chBackplaneTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ChBackplaneEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of backplanes resident in this chassis."
|
|
::= { chassis 2 }
|
|
|
|
chBackplaneEntry OBJECT-TYPE
|
|
SYNTAX ChBackplaneEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A backplane entry containing objects for a particular
|
|
backplane."
|
|
INDEX { chBackplaneID }
|
|
::= { chBackplaneTable 1 }
|
|
|
|
ChBackplaneEntry ::=
|
|
SEQUENCE {
|
|
chBackplaneID
|
|
INTEGER,
|
|
chBackplaneType
|
|
OBJECT IDENTIFIER
|
|
}
|
|
|
|
chBackplaneID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An unique value identifying a backplane within the
|
|
chassis."
|
|
::= { chBackplaneEntry 1 }
|
|
|
|
chBackplaneType OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An authoritative identification that is specific to
|
|
the particular media being used to realize the
|
|
backplane. For example, if the backplane is realized
|
|
by an Ethernet, then the value of this object refers
|
|
to a well known OID defined for Ethernet. If this
|
|
information is not present or unknown, its value
|
|
should be set to OBJECT IDENTIFIER { 0 0 }, which
|
|
is a syntactically valid object identifier."
|
|
::= { chBackplaneEntry 2 }
|
|
|
|
chNumSlots OBJECT-TYPE
|
|
SYNTAX INTEGER (0..64)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of slots in a chassis. For bounded, slot-less
|
|
systems, the value of this object shall be zero(0)."
|
|
::= { chassis 3 }
|
|
|
|
-- Component Table and Definitions
|
|
-- Components are instances of functional devices. For
|
|
-- example, if two routers and three bridges were installed
|
|
-- in a chassis, said chassis accommodates five components.
|
|
|
|
chCompTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ChCompEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of components installed in this chassis."
|
|
::= { chassis 4 }
|
|
|
|
chCompEntry OBJECT-TYPE
|
|
SYNTAX ChCompEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A component entry containing objects for a particular
|
|
component."
|
|
INDEX { chCompID }
|
|
::= { chCompTable 1 }
|
|
|
|
ChCompEntry ::=
|
|
SEQUENCE {
|
|
chCompID
|
|
INTEGER,
|
|
chCompAdminStatus
|
|
INTEGER,
|
|
chCompArg
|
|
OCTET STRING,
|
|
chCompType
|
|
OBJECT IDENTIFIER,
|
|
chCompName
|
|
DisplayString,
|
|
chCompVersion
|
|
DisplayString,
|
|
chCompTimeStamp
|
|
TimeTicks,
|
|
chCompAccessPolicy
|
|
INTEGER,
|
|
chCompBasicCommStr
|
|
OCTET STRING,
|
|
chCompROCommStr
|
|
OCTET STRING,
|
|
chCompRWCommStr
|
|
OCTET STRING,
|
|
chCompSUCommStr
|
|
OCTET STRING,
|
|
chCompNetAdr
|
|
NetworkAddress
|
|
}
|
|
|
|
chCompID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An unique value identifying a component, which includes,
|
|
but is not limited to, routers, bridges, and terminal
|
|
servers. Multiple instances of a functional device may
|
|
exist within the same chassis."
|
|
::= { chCompEntry 1 }
|
|
|
|
chCompAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1), -- none of the following
|
|
invalid(2),
|
|
enabled(3),
|
|
testing(4),
|
|
operational(5),
|
|
error(6),
|
|
disabled(7),
|
|
delete(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Provides the state of the given component. A component
|
|
is activated by writing a value of enabled(3). Once
|
|
enabled, a component enters testing mode, which is
|
|
denoted by testing(4), when this object is read. After
|
|
tests are complete, the component either enters the
|
|
operational(5), or the error(6) state.
|
|
|
|
The component may be de-activated by writing a value of
|
|
disabled(7). In a disabled state, a component does
|
|
exist within the given chassis, but is benign. A disabled
|
|
component is available for subsequent activation."
|
|
::= { chCompEntry 2 }
|
|
|
|
chCompArg OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(32))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A variable that may be passed to a component, when it
|
|
is being either enabled or disabled."
|
|
::= { chCompEntry 3 }
|
|
|
|
chCompType OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Identifies a component within this chassis. A vendor's
|
|
authoritative identification of this component type.
|
|
By convention, this value is allocated within the SMI
|
|
enterprises subtree(1.3.6.1.4.1), and provides an easy
|
|
and unambiguous means for determining the component
|
|
type. If this information is not present or unknown,
|
|
its value should be set to the OBJECT IDENTIFIER { 0 0 },
|
|
which is a syntactically valid object identifier."
|
|
::= { chCompEntry 4 }
|
|
|
|
chCompName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A textual description of the component."
|
|
::= { chCompEntry 5 }
|
|
|
|
chCompVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A textual description of the version/revision level for
|
|
this component's software."
|
|
::= { chCompEntry 6 }
|
|
|
|
chCompTimeStamp OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of sysUpTime of this management entity, when
|
|
this component was last (re-)initialized."
|
|
::= { chCompEntry 7 }
|
|
|
|
chCompAccessPolicy OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1), -- none of the following
|
|
invalid(2),
|
|
same(3), -- current IP address and
|
|
-- community string pair
|
|
-- may be used to access
|
|
-- this component
|
|
otherCommStr(4), -- use community string
|
|
-- specified by
|
|
-- chCompROCommStr (or
|
|
-- chCompRWCommStr), with
|
|
-- current IP address to
|
|
-- access this component.
|
|
-- Community access profile
|
|
-- and view are determined
|
|
-- by the associated
|
|
-- community string that
|
|
-- will be used.
|
|
other(5) -- use community string
|
|
-- specified by
|
|
-- chCompROCommStr (or
|
|
-- chCompRWCommStr), and
|
|
-- address specified by
|
|
-- chCompNetAdr to access
|
|
-- this component.
|
|
-- Community access profile
|
|
-- and view are determined
|
|
-- by the associated
|
|
-- community string that
|
|
-- will be used.
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines access information for the pertinent component."
|
|
::= { chCompEntry 8 }
|
|
|
|
chCompBasicCommStr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Read-only community string for the pertinent component.
|
|
If the value of chCompAccessPolicy is otherCommStr(4) or
|
|
other(5), then this object shall determine the read-only
|
|
Community String to be used when accessing this component.
|
|
This also defined the basic read only community string to
|
|
access MIBs registered to this component."
|
|
::= { chCompEntry 9 }
|
|
|
|
chCompROCommStr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Read-only community string for the pertinent component.
|
|
If the value of chCompAccessPolicy is otherCommStr(4) or
|
|
other(5), then this object shall determine the read-only
|
|
Community String to be used when accessing this component.
|
|
This also defined the read only community string to
|
|
access MIBs registered to this component."
|
|
::= { chCompEntry 10 }
|
|
|
|
chCompRWCommStr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Read-write community string for the pertinent component.
|
|
If the value of chCompAccessPolicy is otherCommStr(4) or
|
|
other(5), then this object shall determine the read-write
|
|
Community String to be used when accessing this component.
|
|
This also defined the read write community string to
|
|
access MIBs registered to this component."
|
|
::= { chCompEntry 11 }
|
|
|
|
chCompSUCommStr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Super user community string for the pertinent component.
|
|
If the value of chCompAccessPolicy is otherCommStr(4) or
|
|
other(5), then this object shall determine the read-write
|
|
Community String to be used when accessing this component.
|
|
This also defined the read write community string to
|
|
access MIBs registered to this component."
|
|
::= { chCompEntry 12 }
|
|
|
|
chCompNetAdr OBJECT-TYPE
|
|
SYNTAX NetworkAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the value of chCompAccessPolicy is other(5), then this
|
|
object shall determine the Network Address to be used to
|
|
access this component. In all other cases, a value of
|
|
0.0.0.0 shall be returned, when read."
|
|
::= { chCompEntry 13 }
|
|
|
|
-- Slot Table and definitions
|
|
-- A module is the physical entity that resides in a chassis slot.
|
|
-- A module is also denoted as a board or card. A component may
|
|
-- be realized by one or more modules, or one or more components
|
|
-- may be realized by the same module.
|
|
-- The slot table provides a physical representation of a chassis
|
|
-- and its components.
|
|
|
|
chSlotTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ChSlotEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of modules installed in this chassis. A component,
|
|
such as a router, may be incorporated on one or more
|
|
modules. More than one component may be incorporated on
|
|
each module."
|
|
::= { chassis 5 }
|
|
|
|
chSlotEntry OBJECT-TYPE
|
|
SYNTAX ChSlotEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A slot entry containing objects for a particular
|
|
module."
|
|
INDEX { chSlotID, chSlotCompID }
|
|
::= { chSlotTable 1 }
|
|
|
|
ChSlotEntry ::=
|
|
SEQUENCE {
|
|
chSlotID
|
|
INTEGER,
|
|
chSlotCompID
|
|
INTEGER,
|
|
chSlotClass
|
|
OBJECT IDENTIFIER,
|
|
chSlotModuleType
|
|
OBJECT IDENTIFIER,
|
|
chSlotModuleName
|
|
DisplayString,
|
|
chSlotModuleVersion
|
|
DisplayString,
|
|
chSlotModuleTimeStamp
|
|
TimeTicks
|
|
}
|
|
|
|
chSlotID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The slot number containing this module. An unique
|
|
value, in the range between 0 and and the value of
|
|
chNumSlots."
|
|
::= { chSlotEntry 1 }
|
|
|
|
chSlotCompID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ID value for the component incorporated within this
|
|
module. This object is similar to chCompID."
|
|
::= { chSlotEntry 2 }
|
|
|
|
chSlotClass OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The class (or type) of slot. For example, slots that
|
|
only allow for power supply modules fall into a class
|
|
that is different from slots that allow only interface
|
|
cards."
|
|
::= { chSlotEntry 3 }
|
|
chSlotModuleType OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Uniquely defines the module type. A vendor's
|
|
authoritative identification for a module. By
|
|
convention, this value is allocated within the SMI
|
|
enterprises subtree(1.3.6.1.4.1), and provides an easy
|
|
and unambiguous means for determining the type of
|
|
module."
|
|
::= { chSlotEntry 4 }
|
|
|
|
chSlotModuleName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A textual description of the module."
|
|
::= { chSlotEntry 5 }
|
|
|
|
chSlotModuleVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A textual description of the version/revision level for
|
|
this module's hardware and firmware."
|
|
::= { chSlotEntry 6 }
|
|
|
|
chSlotModuleTimeStamp OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of sysUpTime for this management entity, when
|
|
this module was last (re-)initialized."
|
|
::= { chSlotEntry 7 }
|
|
|
|
|
|
|
|
-- MIB Table
|
|
-- This table provides a list of MIBs that are incorporated in
|
|
-- the various components within chassis slots.
|
|
|
|
chCompMIBTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ChCompMIBEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A list of MIBs incorporated on components and their
|
|
respective modules, within this chassis."
|
|
::= { chassis 6 }
|
|
|
|
chCompMIBEntry OBJECT-TYPE
|
|
SYNTAX ChCompMIBEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A MIB entry containing objects for a MIB that is
|
|
realized by a particular module."
|
|
INDEX { chCompMIBID, chCompMIBSlotID, chCompMIBCompID }
|
|
::= { chCompMIBTable 1 }
|
|
|
|
ChCompMIBEntry ::=
|
|
SEQUENCE {
|
|
chCompMIBID
|
|
INTEGER,
|
|
chCompMIBSlotID
|
|
INTEGER,
|
|
chCompMIBCompID
|
|
INTEGER,
|
|
chCompMIBGrpOID
|
|
OBJECT IDENTIFIER,
|
|
chCompMIBVectorObjectBase
|
|
OBJECT IDENTIFIER,
|
|
chCompMIBVectorNum
|
|
INTEGER,
|
|
chCompMIBType
|
|
INTEGER,
|
|
chCompMIBStatus
|
|
INTEGER
|
|
}
|
|
|
|
chCompMIBID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"An unique value identifying an instance of a MIB."
|
|
::= { chCompMIBEntry 1 }
|
|
|
|
chCompMIBSlotID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The slot number for the module that incorporates this
|
|
MIB. The value shall be in the range between 0 and
|
|
chNumSlots. A non-zero values indicates that the
|
|
information presented by this entry is realized only
|
|
on the module in the specified slot. A zero value
|
|
indicates that this information pertains to the entire
|
|
component, without partitioning across modules.
|
|
|
|
This object is similar to chSlotID."
|
|
::= { chCompMIBEntry 2 }
|
|
|
|
chCompMIBCompID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The component related to this MIB. This object is
|
|
similar to chCompID."
|
|
::= { chCompMIBEntry 3 }
|
|
|
|
chCompMIBGrpOID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A reference to a specific MIB group definition. For
|
|
example, in the case of MIB-II, the value of this
|
|
object may refer to an applicable group, which has
|
|
been implemented.
|
|
|
|
The access is read-write. This will allow network
|
|
administrators, to register MIBs for a module that is
|
|
known to the chassis management entity, by type alone:
|
|
that is, a module for which component information is
|
|
unknown."
|
|
::= { chCompMIBEntry 4 }
|
|
|
|
chCompMIBVectorObjectBase OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A reference to a specific entry of a vector object
|
|
within this MIB, associated with the module identified
|
|
by chCompMIBSlotID. For example, in the case of a
|
|
repeater, the value of this object may refer to an
|
|
entry in prtrBasicPortTable. This object facilitates
|
|
logical to physical mapping of entities such as
|
|
channels, links, interfaces, and ports."
|
|
::= { chCompMIBEntry 5 }
|
|
|
|
chCompMIBVectorNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A value indicating the number of entries, starting with
|
|
the one denoted by chCompMIBVectorObjectBase, that are
|
|
realized on this module."
|
|
::= { chCompMIBEntry 6 }
|
|
|
|
chCompMIBType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
not-instanced(1),
|
|
instanced(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Depicts whether the MIB in question is instanced
|
|
or not.
|
|
|
|
For reason similar to ones that apply to
|
|
chCompMIBGrpOID, the access mode is read-write."
|
|
::= { chCompMIBEntry 7 }
|
|
|
|
chCompMIBStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
invalid(2),
|
|
agent(3),
|
|
management(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Depicts the status of the MIB. If marked as agent
|
|
the MIB is generated based upon the components
|
|
defined. If marked as management the entry was entered
|
|
via a management station. If marked invalid the
|
|
entry is to be deleted."
|
|
::= { chCompMIBEntry 8 }
|
|
|
|
chPhysicalChanges OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Depicts the number of physical changes that have occured
|
|
to the chassis MIB. This includes additions and
|
|
removal of components in the component table."
|
|
::= { chassis 7 }
|
|
|
|
chLogicalChanges OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Depicts the number of logical changes that have occured
|
|
to the chassis MIB. This includes all sets to name
|
|
strings etc."
|
|
::= { chassis 8 }
|
|
|
|
chCompGlobalBasicCommStr OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..27))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is defined as the base read only community string to
|
|
access MIBs on this module. A write to this object will
|
|
change all instances of chCompBasicCommStr."
|
|
::= { chassis 9 }
|
|
|
|
chCompGlobalROCommStr OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..27))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is defined as the expanded read only community string to
|
|
access MIBs on this module. A write to this object will
|
|
change all instances of chCompROCommStr."
|
|
::= { chassis 10 }
|
|
|
|
chCompGlobalRWCommStr OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..27))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is defined as the read write community string to
|
|
access MIBs on this module. A write to this object will
|
|
change all instances of chCompRWCommStr."
|
|
::= { chassis 11 }
|
|
|
|
chCompGlobalSUCommStr OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..27))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is defined as the super user community string to
|
|
access MIBs on this module. A write to this object will
|
|
change all instances of chCompSUCommStr."
|
|
::= { chassis 12 }
|
|
|
|
END
|