mirror of
https://github.com/librenms/librenms.git
synced 2024-10-07 16:52:45 +00:00
git-svn-id: http://www.observium.org/svn/observer/trunk@1575 61d68cd4-352d-0410-923a-c4978735b2b8
723 lines
23 KiB
Plaintext
723 lines
23 KiB
Plaintext
ELS100-S24TX2M-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
internet
|
|
FROM RFC1155-SMI
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32, IpAddress
|
|
FROM SNMPv2-SMI
|
|
DisplayString
|
|
FROM SNMPv2-TC;
|
|
|
|
|
|
-- private OBJECT IDENTIFIER ::= { internet 4 }
|
|
-- enterprises OBJECT IDENTIFIER ::= { private 1 }
|
|
-- cabletron OBJECT IDENTIFIER ::= { enterprises 52 }
|
|
-- namingTree OBJECT IDENTIFIER ::= { cabletron 3 }
|
|
-- mtExpanded OBJECT IDENTIFIER ::= { namingTree 9 }
|
|
-- mtThrdParty OBJECT IDENTIFIER ::= { mtExpanded 1 }
|
|
-- tpStandAlone OBJECT IDENTIFIER ::= { mtThrdParty 10 }
|
|
|
|
|
|
tpELS100S24TX2M MODULE-IDENTITY
|
|
LAST-UPDATED "200202202202Z" -- Wed Feb 20 22:02 GMT 2002
|
|
ORGANIZATION "Enterasys Networks, Inc."
|
|
CONTACT-INFO
|
|
"Enterasys Networks, Inc.
|
|
35 Industrial Way, P.O. Box 5005
|
|
Rochester, NH 03867-5005
|
|
(603) 332-9400
|
|
support@enterasys.com
|
|
http://www.enterasys.com"
|
|
DESCRIPTION
|
|
"The MIB module for ELS100-S24TX2M."
|
|
|
|
REVISION "200208051753Z" -- Mon Aug 5 17:53 GMT 2002
|
|
DESCRIPTION
|
|
"Added switchOIDTable for identifying the individual
|
|
switches in a stack of switches."
|
|
|
|
REVISION "200202202202Z" -- Wed Feb 20 22:02 GMT 2002
|
|
DESCRIPTION
|
|
"Pretty print."
|
|
|
|
REVISION "199910010000Z"
|
|
DESCRIPTION
|
|
"Initial version of this MIB."
|
|
-- ::= { tpStandAlone 7 }
|
|
::= { internet private(4) enterprises(1) cabletron(52)
|
|
namingTree(3) mtExpanded(9) mtThrdParty(1)
|
|
tpStandAlone(10) tpELS100S24TX2M(7) }
|
|
|
|
|
|
switchInfo OBJECT IDENTIFIER ::= { tpELS100S24TX2M 1 }
|
|
switchPortMgt OBJECT IDENTIFIER ::= { tpELS100S24TX2M 2 }
|
|
systemSTAMgt OBJECT IDENTIFIER ::= { tpELS100S24TX2M 3 }
|
|
tftpDownloadMgt OBJECT IDENTIFIER ::= { tpELS100S24TX2M 4 }
|
|
restartMgt OBJECT IDENTIFIER ::= { tpELS100S24TX2M 5 }
|
|
portMirrorMgt OBJECT IDENTIFIER ::= { tpELS100S24TX2M 6 }
|
|
igmpMgt OBJECT IDENTIFIER ::= { tpELS100S24TX2M 7 }
|
|
|
|
|
|
--
|
|
-- switchInfo
|
|
--
|
|
|
|
switchNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of switches present on this system."
|
|
::= { switchInfo 1 }
|
|
|
|
|
|
switchInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwitchInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of descriptive and status information about
|
|
switches in this system."
|
|
::= { switchInfo 2 }
|
|
|
|
switchInfoEntry OBJECT-TYPE
|
|
SYNTAX SwitchInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing information
|
|
about a single switch in this system. "
|
|
INDEX { swUnitIndex }
|
|
::= { switchInfoTable 1 }
|
|
|
|
SwitchInfoEntry ::= SEQUENCE
|
|
{
|
|
swUnitIndex Integer32,
|
|
swMainBoardHwVer DisplayString,
|
|
swMainBoardFwVer DisplayString,
|
|
swAgentBoardHwVer DisplayString,
|
|
swAgentBoardFwVer DisplayString,
|
|
swAgentBoardPOSTCodeVer DisplayString,
|
|
swPortNumber Integer32,
|
|
swPowerStatus INTEGER,
|
|
swExpansionSlot1 INTEGER,
|
|
swExpansionSlot2 INTEGER,
|
|
swRoleInSystem INTEGER
|
|
}
|
|
|
|
swUnitIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the switch within the system
|
|
for which this entry contains information. This
|
|
value can never be greater than switchNumber."
|
|
::= { switchInfoEntry 1 }
|
|
|
|
swMainBoardHwVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hardware version of the main board."
|
|
::= { switchInfoEntry 2 }
|
|
|
|
swMainBoardFwVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firmware version of the main board."
|
|
::= { switchInfoEntry 3 }
|
|
|
|
swAgentBoardHwVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hardware version of the agent board."
|
|
::= { switchInfoEntry 4 }
|
|
|
|
swAgentBoardFwVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firmware version of the agent board."
|
|
::= { switchInfoEntry 5 }
|
|
|
|
swAgentBoardPOSTCodeVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"POST code version of the agent board."
|
|
::= { switchInfoEntry 6 }
|
|
|
|
swPortNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total port number of this switch
|
|
(including expansion slot)."
|
|
::= { switchInfoEntry 7 }
|
|
|
|
swPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
internalPower(1),
|
|
redundantPower(2),
|
|
internalAndRedundantPower(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the switch using internalPower(1),
|
|
redundantPower(2) or both(3)"
|
|
::= { switchInfoEntry 8 }
|
|
|
|
swExpansionSlot1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
hundredBaseFX2Port(1),
|
|
thousandBaseSX(2),
|
|
stackingModule4GB(3),
|
|
hundredBaseFX1Port(4),
|
|
thousandBaseLX(5),
|
|
thousandBaseT(6),
|
|
thousandBaseGBIC(7),
|
|
stackingModule2GB(8),
|
|
other(9),
|
|
notPresent(10)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of expansion module in this switch slot 1."
|
|
::= { switchInfoEntry 9 }
|
|
|
|
swExpansionSlot2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
hundredBaseFX2Port(1),
|
|
thousandBaseSX(2),
|
|
stackingModule4GB(3),
|
|
hundredBaseFX1Port(4),
|
|
thousandBaseLX(5),
|
|
thousandBaseT(6),
|
|
thousandBaseGBIC(7),
|
|
stackingModule2GB(8),
|
|
other(9),
|
|
notPresent(10)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of expansion module in this switch slot 2."
|
|
::= { switchInfoEntry 10 }
|
|
|
|
swRoleInSystem OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
master(1),
|
|
backupMaster(2),
|
|
slave(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the switch is master(1), backupMaster(2)
|
|
or slave(3) in this system."
|
|
::= { switchInfoEntry 11 }
|
|
|
|
|
|
switchOIDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwitchOIDEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of System Object Identifiers for switches
|
|
in this system."
|
|
::= { switchInfo 3 }
|
|
|
|
switchOIDEntry OBJECT-TYPE
|
|
SYNTAX SwitchOIDEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing System Object
|
|
Identifier for a single switch in this system."
|
|
INDEX { switchOIDIndex }
|
|
::= { switchOIDTable 1 }
|
|
|
|
SwitchOIDEntry ::= SEQUENCE
|
|
{
|
|
switchOIDIndex INTEGER,
|
|
switchOIDValue OBJECT IDENTIFIER
|
|
}
|
|
|
|
switchOIDIndex OBJECT-TYPE
|
|
SYNTAX INTEGER( 1 .. 65535 )
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the switch within the system
|
|
for which this entry contains information. This
|
|
value can never be greater than switchNumber.
|
|
|
|
Index value 1 always represents the Master in a
|
|
stacked configuration and the only device in a
|
|
standalone configuration.
|
|
|
|
Subsequent indices are sequential with the lowest
|
|
number representing the Slave nearest the Master
|
|
and so on."
|
|
::= { switchOIDEntry 1 }
|
|
|
|
switchOIDValue OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the System Object Identifier
|
|
that uniquely identifies the type of switch."
|
|
::= { switchOIDEntry 2 }
|
|
|
|
|
|
--
|
|
-- switchPortMgt
|
|
--
|
|
|
|
switchPortMgtTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwitchPortMgtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of descriptive and status information about
|
|
configuration of each switch ports (including
|
|
expansion slot) in this system."
|
|
::= { switchPortMgt 1 }
|
|
|
|
switchPortMgtEntry OBJECT-TYPE
|
|
SYNTAX SwitchPortMgtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table, containing information about
|
|
configuration in one switch port of the switch."
|
|
INDEX { swUnitIndex, swPortMgtIndex }
|
|
::= { switchPortMgtTable 1 }
|
|
|
|
SwitchPortMgtEntry ::= SEQUENCE
|
|
{
|
|
swPortMgtIndex Integer32,
|
|
swPortMgtPortType INTEGER,
|
|
swPortMgtSpeedDpxAdmin INTEGER,
|
|
swPortMgtSpeedDpxInUse INTEGER,
|
|
swPortMgtFlowCtrlAdmin INTEGER,
|
|
swPortMgtFlowCtrlInUse INTEGER
|
|
}
|
|
|
|
swPortMgtIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the port within the switch
|
|
for which this entry contains information."
|
|
::= { switchPortMgtEntry 1 }
|
|
|
|
swPortMgtPortType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
hundredBaseTX(1),
|
|
hundredBaseFX(2),
|
|
thousandBaseSX(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the port type is tenBaseT/hundredBaseTX(1),
|
|
hundredBaseFX(2) or thousandBaseSX(3)."
|
|
::= { switchPortMgtEntry 2 }
|
|
|
|
swPortMgtSpeedDpxAdmin OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
halfDuplex10(1),
|
|
fullDuplex10(2),
|
|
halfDuplex100(3),
|
|
fullDuplex100(4),
|
|
halfDuplex1000(5),
|
|
fullDuplex1000(6),
|
|
autoNegotiation(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set the port speed and duplex mode as follows:
|
|
halfDuplex10(1) - 10Mbps and half duplex mode
|
|
fullDuplex10(2) - 10Mbps and full duplex mode
|
|
halfDuplex100(3) - 100Mbps and half duplex mode
|
|
fullDuplex100(4) - 100Mbps and full duplex mode
|
|
halfDuplex1000(5) - 1000Mbps and half duplex mode
|
|
fullDuplex1000(6) - 1000Mbps and full duplex mode
|
|
autoNegotiation(7) - let the switch to negotiate with
|
|
the other end of connection.
|
|
hundredBaseTX port can be set as
|
|
halfDuplex10(1)
|
|
fullDuplex10(2)
|
|
halfDuplex100(3)
|
|
fullDuplex100(4)
|
|
autoNegotiation(7)
|
|
|
|
hundredBaseFX port can be set as
|
|
halfDuplex100(3)
|
|
fullDuplex100(4)
|
|
|
|
thousandBaseSX port can be set as
|
|
halfDuplex1000(5)
|
|
fullDuplex1000(6)
|
|
autoNegotiation(7)
|
|
|
|
The actual operating speed and duplex of the port is
|
|
given by swPortMgtSpeedDpxInUse."
|
|
DEFVAL { autoNegotiation }
|
|
::= { switchPortMgtEntry 3 }
|
|
|
|
swPortMgtSpeedDpxInUse OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
halfDuplex10(1),
|
|
fullDuplex10(2),
|
|
halfDuplex100(3),
|
|
fullDuplex100(4),
|
|
halfDuplex1000(5),
|
|
fullDuplex1000(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operating speed and duplex mode of the switched port."
|
|
::= { switchPortMgtEntry 4 }
|
|
|
|
swPortMgtFlowCtrlAdmin OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2),
|
|
backPressure(3),
|
|
dot3xFlowControl(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"(1) Flow control mechanism is enabled.
|
|
|
|
If the port type is hundredBaseTX or thousandBaseSX:
|
|
When the port is operating in halfDuplex mode,
|
|
the port uses backPressure flow control mechanism.
|
|
When the port is operating in fullDuplex mode,
|
|
the port uses IEEE 802.3x flow control mechanism.
|
|
|
|
If the port type is hundredBaseFX:
|
|
When the port is operating in halfDuplex mode, the
|
|
port uses backPressure flow control mechanism. When
|
|
the port is operating in fullDuplex mode, Flow
|
|
control mechanism will not function.
|
|
|
|
(2) Flow control mechanism is disabled.
|
|
|
|
(3) Flow control mechanism is backPressure.
|
|
|
|
When the port is in fullDuplex mode
|
|
this flow control mechanism will not function.
|
|
|
|
(4) Flow control mechanism is IEEE 802.3x flow control.
|
|
|
|
When the port is in halfDuplex mode
|
|
this flow control mechanism will not function.
|
|
|
|
hundredBaseTX and thousandBaseSX port can be set as:
|
|
enabled(1),
|
|
disabled(2),
|
|
backPressure(3),
|
|
dot3xFlowControl(4).
|
|
|
|
hundredBaseFX port can be set as:
|
|
enabled(1),
|
|
disabled(2),
|
|
backPressure(3).
|
|
The actual flow control mechanism is used given by
|
|
swPortMgtFlowCtrlInUse."
|
|
DEFVAL { enabled }
|
|
::= { switchPortMgtEntry 5 }
|
|
|
|
swPortMgtFlowCtrlInUse OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
backPressure(1),
|
|
dot3xFlowControl(2),
|
|
none(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"(1) BackPressure flow control mechanism is used.
|
|
(2) IEEE 802.3 flow control mechanism is used.
|
|
(3) Flow control mechanism is disabled. "
|
|
::= { switchPortMgtEntry 6 }
|
|
|
|
|
|
--
|
|
-- systemSTAMgt
|
|
--
|
|
|
|
systemSTAStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Global spanning tree status.
|
|
(1) Spanning tree protocol is enabled.
|
|
(2) Spanning tree protocol is disabled. "
|
|
DEFVAL { enabled }
|
|
::= { systemSTAMgt 1 }
|
|
|
|
--
|
|
-- tftpDownloadMgt
|
|
--
|
|
|
|
tftpDownloadServerIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address of a TFTP server from which a
|
|
firmware image can be downloaded."
|
|
DEFVAL { '00000000'H }
|
|
::= { tftpDownloadMgt 1 }
|
|
|
|
--tftpDownloadMainBoardFwFileName OBJECT-TYPE
|
|
-- SYNTAX DisplayString(SIZE(0..80))
|
|
-- MAX-ACCESS read-write
|
|
-- STATUS current
|
|
-- DESCRIPTION ""
|
|
-- DEFVAL { "es3526f.bin" }
|
|
-- ::= { tftpDownloadMgt 2 }
|
|
|
|
--tftpDownloadMainBoardFwSelected OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- selected(1),
|
|
-- notSelected(2)
|
|
-- }
|
|
-- MAX-ACCESS read-write
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "Setting this object as selected. The system will download
|
|
-- main board firmware when the download action be trigged."
|
|
-- DEFVAL { notSelected }
|
|
-- ::= { tftpDownloadMgt 3 }
|
|
|
|
tftpDownloadAgentBoardFwFileName OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..80))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
DEFVAL { "es3526f.bin" }
|
|
::= { tftpDownloadMgt 2 }
|
|
|
|
tftpDownloadAgentBoardFwDownloadNode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
permanent(1),
|
|
temporary(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether a newly upgraded firmware
|
|
version should write to flash. When this object
|
|
is temporary(2), following a successful upgrade
|
|
the system will switch to run the new firmware but
|
|
will not upgrade the new firmware to flash. That
|
|
means after a power cycle, system will run the
|
|
firmware residing the flash.
|
|
When this object is permanent(1), following a
|
|
successful firmware upgrade, the flash will be
|
|
upgraded and the system will automatically switch
|
|
to run the new firmware."
|
|
DEFVAL { permanent }
|
|
::= { tftpDownloadMgt 3 }
|
|
|
|
--tftpDownloadAgentBoardFwSelected OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- selected(1),
|
|
-- notSelected(2)
|
|
-- }
|
|
-- MAX-ACCESS read-write
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "Setting this object as selected. The system will download
|
|
-- agent board firmware when the download action be trigged."
|
|
-- DEFVAL { notSelected }
|
|
-- ::= { tftpDownloadMgt 4 }
|
|
|
|
tftpDownloadStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
active(1),
|
|
notActive(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to active(1) trigger the TFTP
|
|
download action. Setting this object to notActive(2)
|
|
has no effect. The system always returns the value
|
|
notActive(2) when this object is read."
|
|
::= { tftpDownloadMgt 4 }
|
|
|
|
--
|
|
-- restartMgt
|
|
--
|
|
|
|
restartOptionPOST OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object as enabled. The system will do POST
|
|
when it restart"
|
|
DEFVAL { enabled }
|
|
::= { restartMgt 1 }
|
|
|
|
restartOptionReloadFactoryDefault OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object as enabled. The system will do
|
|
factory reset when it restart"
|
|
DEFVAL { disabled }
|
|
::= { restartMgt 2 }
|
|
|
|
restartOptionKeepIpSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object as enabled. The system will keep IP
|
|
setting when it do factory reset."
|
|
DEFVAL { enabled }
|
|
::= { restartMgt 3 }
|
|
|
|
restartOptionKeepUserAuthentication OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object as enabled. The system will keep
|
|
user authentication setting when it do factory reset."
|
|
DEFVAL { enabled }
|
|
::= { restartMgt 4 }
|
|
|
|
restartAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
active(1),
|
|
notActive(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to active(1) trigger the system
|
|
restart. Setting this object to notActive(2) has
|
|
no effect. The system always returns the value
|
|
notActive(2) when this object is read."
|
|
::= { restartMgt 5 }
|
|
|
|
--
|
|
-- portMirrorMgt
|
|
--
|
|
|
|
portMirrorStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port mirroring function status.
|
|
(1) mirroring function is enabled.
|
|
(2) mirroring function is disabled."
|
|
::= { portMirrorMgt 1 }
|
|
|
|
portMirrorSnifferPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Linear port number of sniffer port to which all
|
|
frames to/from mirrored ports are sent. Frames
|
|
are only mirrored if the portMirrorStatus object
|
|
is set to enabled(1)."
|
|
::= { portMirrorMgt 2 }
|
|
|
|
|
|
portMirrorMirroredPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Linear port number of mirrored port. The traffic of
|
|
mirrored port will be 'copied' to sniffer port."
|
|
::= { portMirrorMgt 3 }
|
|
|
|
--
|
|
-- igmpMgt
|
|
--
|
|
|
|
igmpStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Parameter to enable or disable IGMP snooping on the device.
|
|
When enabled, the device will examine IGMP packets and set
|
|
up filters for IGMP ports. The default is enabled."
|
|
::= { igmpMgt 1 }
|
|
|
|
igmpQueryCount OBJECT-TYPE
|
|
SYNTAX INTEGER (2..16)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum number of queries that have not been heard on the
|
|
system before the system starts taking action to solicit
|
|
reports(default is 5)."
|
|
::= { igmpMgt 2 }
|
|
|
|
|
|
igmpReportDelay OBJECT-TYPE
|
|
SYNTAX INTEGER (3..10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timeout value(mins) between IGMP reports received on a port
|
|
for an IP Multicast Address that can pass before the system
|
|
sends an IGMP Query out the port and removes it from the
|
|
list(default is 5 minutes)."
|
|
::= { igmpMgt 3 }
|
|
|
|
END
|