Files
librenms-librenms/mibs/telco-systems/binox/PRVT-RESILIENT-LINK-MIB
Tony Murray 11147d3bbf Major Processors rewrite (#8066)
* Extract DiscoveryItem and move some things to better places.
Extract model class
Fix up model construction.  I have problem with construction...
Makeshift model working.  Switch constructor to factory.  discover() and create()
Support legacy discovery.
Remove uneeded custom pollers
Remove netonix custom detection as we try ucd on all os now.
Add a few yaml procs.  Fix a couple things.
More processor discovery conversions
Move Calix e7 to standard hrProcessorLoad, but it doesn't fully implement the HR-MIB, move things around to make it work.
Add a few yaml procs.  Fix a couple things. Correct some stupid mib stuff.
Move more, drop php 5.3
Add netscaler which uses string indexes.  Port fiberhome to yaml and use skip_values
More conversions.  BroadcomProcessorUsage Trait
Serveriron and Ironware share some mibs.  Create a common abstract os for them.
Add yaml support for mib specification in each data entry
Make legacy discover_processor() set 0 for hrDeviceIndex

Untangle Dell switch OS processors

Use use shared OS for groups if they don't have a specific group.
fix silly mib mistake

Make index optional

Move HR and UCD to Traits and out of Processor.

* forgot to update the fortiswitch index

* Make sgos and avaya-ers match the old index.

* fix comware test data

* fix merge errors

* fix dsm and remove pointless empty modules

* file not found exception is in the wrong place.

* Updated processor development docs
2018-02-05 07:39:13 -06:00

174 lines
6.0 KiB
Plaintext

-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-RESILIENT-LINK-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
PRVT-RESILIENT-LINK-MIB DEFINITIONS ::= BEGIN
IMPORTS
InterfaceIndex, InterfaceIndexOrZero
FROM IF-MIB
switch
FROM PRVT-SWITCH-MIB
Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE,
Unsigned32
FROM SNMPv2-SMI
RowStatus, TruthValue
FROM SNMPv2-TC;
prvtResilientLinkMIB MODULE-IDENTITY
LAST-UPDATED "201005170000Z"
ORGANIZATION
"BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"The Resilient Link MIB module for managing switch or ipSwitch
resilient link"
REVISION "201005170000Z"
DESCRIPTION
"Initial version."
::= { switch 4 }
prvtResilientLinkNotifications OBJECT IDENTIFIER
::= { prvtResilientLinkMIB 0 }
prvtResilientLinkObjects OBJECT IDENTIFIER
::= { prvtResilientLinkMIB 1 }
prvtResilientLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtResilientLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains config and status information for resilient links."
::= { prvtResilientLinkObjects 1 }
prvtResilientLinkEntry OBJECT-TYPE
SYNTAX PrvtResilientLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in prvtResilientLinkTable."
INDEX { prvtResilientLinkIndex }
::= { prvtResilientLinkTable 1 }
PrvtResilientLinkEntry ::= SEQUENCE {
prvtResilientLinkIndex Integer32,
prvtResilientLinkRowStatus RowStatus,
prvtResilientLinkPrimaryPort InterfaceIndex,
prvtResilientLinkBackupPort InterfaceIndex,
prvtResilientLinkBackupMode INTEGER,
prvtResilientLinkStatusActive InterfaceIndexOrZero,
prvtResilientLinkStatusSwaps Unsigned32
}
prvtResilientLinkIndex OBJECT-TYPE
SYNTAX Integer32 (1..256)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object uniquely identifies the resilient link."
::= { prvtResilientLinkEntry 1 }
prvtResilientLinkRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RowStatus for prvtResilientLinkTable."
::= { prvtResilientLinkEntry 2 }
prvtResilientLinkPrimaryPort OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The primary port for the resilient link."
::= { prvtResilientLinkEntry 3 }
prvtResilientLinkBackupPort OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The back-up port for the resilient link."
::= { prvtResilientLinkEntry 4 }
prvtResilientLinkBackupMode OBJECT-TYPE
SYNTAX INTEGER { standby(1), shutdown(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Configures the behavior of the back-up link."
::= { prvtResilientLinkEntry 5 }
prvtResilientLinkStatusActive OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The currently selected active port.
A value of zero indicates that neither port has yet been selected as the active port."
::= { prvtResilientLinkEntry 7 }
prvtResilientLinkStatusSwaps OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the resilient link's ports have swapped states.
(i.e. the number of times that prvtResilientLinkStatusActive has changed."
::= { prvtResilientLinkEntry 8 }
prvtResilientLinkStatusChange NOTIFICATION-TYPE
OBJECTS { prvtResilientLinkPrimaryPort,
prvtResilientLinkBackupPort }
STATUS current
DESCRIPTION
"The resilientLinkStatusChange trap indicates that
the sending agent monitor detected a change in the status of the
resilient link, identified by resilientLinkIndex."
::= { prvtResilientLinkNotifications 1 }
END -- end of module PRVT-RESILIENT-LINK-MIB.