DLM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- dlm-mib.txt
|
|
-- Revision: 1.03.00
|
|
-- Part Number: 2170566-02
|
|
-- Date: August 14, 1995
|
|
|
|
-- Cabletron Systems, Inc.
|
|
-- 35 Industrial Way, P.O. Box 5005
|
|
-- Rochester, NH 03867-0505
|
|
-- (603) 332-9400
|
|
-- support@ctron.com
|
|
|
|
-- This module provides authoritative definitions for part
|
|
-- of the naming tree below:
|
|
--
|
|
-- cabletron { enterprises 52 }
|
|
--
|
|
-- This module will be extended, as additional sub-sections
|
|
-- of this naming tree are defined.
|
|
--
|
|
|
|
-- Cabletron Systems reserves the right to make changes in
|
|
-- specification and other information contained in this document
|
|
-- without prior notice. The reader should consult Cabletron Systems
|
|
-- to determine whether any such changes have been made.
|
|
--
|
|
-- In no event shall Cabletron Systems be liable for any incidental,
|
|
-- indirect, special, or consequential damages whatsoever (including
|
|
-- but not limited to lost profits) arising out of or related to this
|
|
-- document or the information contained in it, even if Cabletron
|
|
-- Systems has been advised of, known, or should have known, the
|
|
-- possibility of such damages.
|
|
--
|
|
-- Cabletron grants vendors, end-users, and other interested parties
|
|
-- a non-exclusive license to use this Specification in connection
|
|
-- with the management of Cabletron products.
|
|
|
|
-- Copyright August 95 Cabletron Systems
|
|
|
|
IMPORTS
|
|
IpAddress, Counter, Gauge, TimeTicks
|
|
FROM RFC1155-SMI
|
|
ctronDLM FROM CTRON-MIB-NAMES
|
|
OBJECT-TYPE
|
|
FROM RFC-1212;
|
|
|
|
-- Formal definitions for Distributed LAN Monitor
|
|
|
|
|
|
snmpPollTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnmpPollEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of SNMP poll entries which trigger automatic polling
|
|
of SNMP requests to other SNMP agents. This table is indexed
|
|
by the destination IP address of the host/device to be polled
|
|
and the IP address of the requesting host. This indexing pair
|
|
allows multiple requestors to define a poll request to the same
|
|
destination, yet maintain separate poll entries.
|
|
|
|
The OIDs to be polled in this request are defined in the
|
|
snmpOIDTable which is indexed also by the destination/owner
|
|
IP address pair. If no OIDs are defined for a poll entry, then
|
|
the the poll will default to polling for sysUpTimei with no
|
|
threshold comparison. This will act as a simple keep-alive
|
|
funtion for the destination SNMP agent."
|
|
::= { ctronDLM 1 }
|
|
|
|
|
|
snmpPollEntry OBJECT-TYPE
|
|
SYNTAX SnmpPollEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An SNMP poll entry containing objects for a particular poll
|
|
request."
|
|
INDEX { snmpPollDestination, snmpPollOwner }
|
|
::= { snmpPollTable 1 }
|
|
|
|
SnmpPollEntry ::=
|
|
SEQUENCE {
|
|
snmpPollDestination IpAddress,
|
|
snmpPollOwner IpAddress,
|
|
snmpPollCommunity OCTET STRING,
|
|
snmpPollInterval INTEGER,
|
|
snmpPollRetry INTEGER,
|
|
snmpPollAction INTEGER,
|
|
snmpPollTrapAddress IpAddress,
|
|
snmpPollType INTEGER,
|
|
snmpPollStatus INTEGER,
|
|
snmpPollRequests Counter,
|
|
snmpPollLastContact TimeTicks,
|
|
snmpPollLastAlarm TimeTicks,
|
|
snmpPollAlarmWait INTEGER,
|
|
snmpPollTrapCommunity OCTET STRING,
|
|
snmpPollProtocol INTEGER
|
|
}
|
|
|
|
|
|
snmpPollDestination OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the host/device to be polled."
|
|
::= { snmpPollEntry 1 }
|
|
|
|
snmpPollOwner OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the client which created this poll
|
|
request entry."
|
|
::= { snmpPollEntry 2 }
|
|
|
|
|
|
snmpPollCommunity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the community string to be used in the SNMP
|
|
REQUEST PDU when actively polling. Note that this community
|
|
name string should be defined for the Cabletron hub device
|
|
as well as in the destination host/device; otherwise polls
|
|
can fail due to authenication failures."
|
|
DEFVAL { "public" }
|
|
::= { snmpPollEntry 3 }
|
|
|
|
|
|
snmpPollInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the interval (in seconds) on which to poll the
|
|
destination address with the OIDs defined in the OID table
|
|
assigned to this poll entry. This interval defines how often
|
|
an SNMP GET REQUEST PDU will be originated from this host
|
|
device to the polled address."
|
|
DEFVAL { 60 }
|
|
::= { snmpPollEntry 4 }
|
|
|
|
snmpPollRetry OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the number of times to retry a failed poll request
|
|
prior to considering it a failure."
|
|
DEFVAL { 3 }
|
|
::= { snmpPollEntry 5 }
|
|
|
|
|
|
snmpPollAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no-action(1),
|
|
send-trap(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The indication of the action to take when a poll request is
|
|
considered to have failed. A value of 'no-action' will allow
|
|
the poll to reset and retry without sending any alarms. A value
|
|
of 'send-trap' will cause a SNMP TRAP PDU to be generated and
|
|
sent to the specified trap address for this entry."
|
|
DEFVAL { send-trap }
|
|
::= { snmpPollEntry 6 }
|
|
|
|
snmpPollTrapAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address to which to send the SNMP TRAP if the poll is
|
|
considered a failure and the action is defined as send-trap.
|
|
The default trap address is the owner address for this entry."
|
|
-- DEFVAL { snmpPollOwner }
|
|
::= { snmpPollEntry 7 }
|
|
|
|
snmpPollType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
invalid(2),
|
|
activate(3),
|
|
suspend(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The administrative control of this poll request entry. This
|
|
leaf is used to trigure an active request (begin polling),
|
|
suspend polling (stop polling but leave this poll entry intact)
|
|
on an active request, or to delete an entry (stop polling and
|
|
remove entry)."
|
|
DEFVAL { activate }
|
|
::= { snmpPollEntry 8 }
|
|
|
|
snmpPollStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inactive(1),
|
|
active(2),
|
|
lost-contact(3),
|
|
alarm-condition(4),
|
|
general-failure(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The operational status of this poll request entry. This leaf
|
|
is used to indicate the state of the last valid poll request."
|
|
::= { snmpPollEntry 9 }
|
|
|
|
|
|
snmpPollRequests OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the number of poll requests (SNMP GET REQUEST PDUs)
|
|
have been issued for this poll entry."
|
|
::= { snmpPollEntry 10 }
|
|
|
|
|
|
snmpPollLastContact OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the value of the sysUpTime when the last poll
|
|
response was received from the polled host/device for which
|
|
this poll entry exists."
|
|
::= { snmpPollEntry 11 }
|
|
|
|
|
|
snmpPollLastAlarm OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the value of the sysUpTime when the last alarm
|
|
was generated for this poll request entry."
|
|
::= { snmpPollEntry 12 }
|
|
|
|
snmpPollAlarmWait OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the number of seconds to wait prior to sending
|
|
another alarm. This is to ensure that alarms do not flood
|
|
out upon device contact lost."
|
|
DEFVAL { 60 }
|
|
::= { snmpPollEntry 13 }
|
|
|
|
snmpPollTrapCommunity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the community string to be used in the SNMP
|
|
TRAP PDU when a trap is generated."
|
|
DEFVAL { "public" }
|
|
::= { snmpPollEntry 14 }
|
|
|
|
snmpPollProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
internet-ping(1),
|
|
snmp(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the protocol to use to poll the host/device. If
|
|
snmp is chosen, there must be at least one corresponding
|
|
OID Table Entry or a general-failure will result. A
|
|
corresponding OID Table Entry is an entry with the same
|
|
Destination and Owner indices."
|
|
DEFVAL { internet-ping }
|
|
::= { snmpPollEntry 15 }
|
|
|
|
|
|
-- The OID request table used in the SNMP polling for threshold/value
|
|
-- comparisons.
|
|
|
|
snmpOIDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnmpOIDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of objects used to define the OBJECT IDENTIFIERS and
|
|
their attributes (type and threashold values) to be used in
|
|
a particular snmp poll request SNMP GET REQUEST PDU. These
|
|
OIDs will make up the VarBindList in the PDU. Only OID types
|
|
which have INTEGER samantics are supported (INTEGER, Counter,
|
|
Gauge, TimeTicks) since the polled value is compared against
|
|
a threshold value.
|
|
|
|
This table is addresses by the same keys as the snmpPollTable
|
|
(destination IP address and owner Ip address) in addition to
|
|
a unique OID sequence number which is maintained for each
|
|
OID entry."
|
|
::= { ctronDLM 2 }
|
|
|
|
snmpOIDEntry OBJECT-TYPE
|
|
SYNTAX SnmpOIDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An SNMP poll OBJECT IDENTIFIER entry containing objects for a
|
|
particular OID to be polled."
|
|
INDEX { snmpOIDDestination, snmpOIDOwner, snmpOIDSequence }
|
|
::= { snmpOIDTable 1 }
|
|
|
|
SnmpOIDEntry ::=
|
|
SEQUENCE {
|
|
snmpOIDDestination IpAddress,
|
|
snmpOIDOwner IpAddress,
|
|
snmpOIDSequence INTEGER,
|
|
snmpOIDObject OBJECT IDENTIFIER,
|
|
snmpOIDComparator INTEGER,
|
|
snmpOIDEnumType INTEGER,
|
|
snmpOIDThresholdInteger INTEGER,
|
|
snmpOIDThresholdCounter Counter,
|
|
snmpOIDThresholdGauge Gauge,
|
|
snmpOIDThresholdTicks TimeTicks,
|
|
snmpOIDType INTEGER,
|
|
snmpOIDStatus INTEGER,
|
|
snmpOIDLastValue INTEGER
|
|
}
|
|
|
|
|
|
snmpOIDDestination OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the host/device to be polled."
|
|
::= { snmpOIDEntry 1 }
|
|
|
|
snmpOIDOwner OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the client which created this OID
|
|
request entry."
|
|
::= { snmpOIDEntry 2 }
|
|
|
|
snmpOIDSequence OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sequence number which uniquely idenifies this OID entry
|
|
entry within a particular SNMP poll request. This number is
|
|
incremented each time an OID as added to the poll list for a
|
|
particular destination/owner pair."
|
|
::= { snmpOIDEntry 3 }
|
|
|
|
|
|
snmpOIDObject OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Identifies the Object Identifier to be polled. This OID value
|
|
will be placed in a SNMP GET REQUEST PDU on each poll interval."
|
|
-- DEFVAL { sysUpTime }
|
|
::= { snmpOIDEntry 4 }
|
|
|
|
|
|
snmpOIDComparator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
equal(1),
|
|
greater(2),
|
|
less(3),
|
|
greater-or-equal(4),
|
|
less-or-equal(5),
|
|
trap-always(6),
|
|
dont-compare(7),
|
|
not-equal(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the type of comparison to be performed on the value
|
|
portion of the OID being polled. This comparator will be used
|
|
to compare the OID value with the threshold value defined in
|
|
this entry. A value of 'dont-compare' causes no comparison to
|
|
be performed. Comparison failures will trigger an alarm
|
|
condition."
|
|
DEFVAL { dont-compare }
|
|
::= { snmpOIDEntry 5 }
|
|
|
|
|
|
snmpOIDEnumType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
integer(1),
|
|
counter(2),
|
|
gauge(3),
|
|
ticks(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the type of value to expect from the OID being polled
|
|
such that the correct interpretation of the threshold value can
|
|
be used to do the comparison."
|
|
DEFVAL { ticks }
|
|
::= { snmpOIDEntry 6 }
|
|
|
|
|
|
snmpOIDThresholdInteger OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The threshold value to be used when polling an integer-valued
|
|
Object Identifier."
|
|
DEFVAL { 0 }
|
|
::= { snmpOIDEntry 7 }
|
|
|
|
|
|
snmpOIDThresholdCounter OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The threshold value to be used when polling a Counter-type
|
|
Object Identifier."
|
|
::= { snmpOIDEntry 8 }
|
|
|
|
|
|
snmpOIDThresholdGauge OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The threshold value to be used when polling a Gauge-type
|
|
Object Identifier."
|
|
::= { snmpOIDEntry 9 }
|
|
|
|
snmpOIDThresholdTicks OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The threshold value to be used when polling a TimeTicks-type
|
|
Object Identifier."
|
|
DEFVAL { 0 }
|
|
::= { snmpOIDEntry 10 }
|
|
|
|
|
|
snmpOIDType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
inactive(2),
|
|
activate(3),
|
|
suspend(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The administrative control of this Object Identifier entry.
|
|
This leaf is used to control adding, using, and deleting OIDs
|
|
from the OID poll list."
|
|
DEFVAL { activate }
|
|
::= { snmpOIDEntry 11 }
|
|
|
|
snmpOIDStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inactive(1),
|
|
active(2),
|
|
alarm-condition(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the last poll of this Object ID."
|
|
::= { snmpOIDEntry 12 }
|
|
|
|
snmpOIDLastValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the last poll entry treated as an integer value.
|
|
This field is used to allow RMON alarms to monitor the polled
|
|
values."
|
|
::= { snmpOIDEntry 13 }
|
|
|
|
END
|