ENTERASYS-SPANNING-TREE-DIAGNOSTIC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- enterasys-spanning-tree-diagnostic-mib.txt
|
|
--
|
|
-- Part Number:
|
|
--
|
|
--
|
|
|
|
-- This module provides authoritative definitions for Enterasys
|
|
-- Networks' IEEE Spanning Tree Diagnostic MIB.
|
|
|
|
--
|
|
-- This module will be extended, as needed.
|
|
|
|
-- Enterasys Networks reserves the right to make changes in this
|
|
-- specification and other information contained in this document
|
|
-- without prior notice. The reader should consult Enterasys Networks
|
|
-- to determine whether any such changes have been made.
|
|
--
|
|
-- In no event shall Enterasys Networks be liable for any incidental,
|
|
-- indirect, special, or consequential damages whatsoever (including
|
|
-- but not limited to lost profits) arising out of or related to this
|
|
-- document or the information contained in it, even if Enterasys
|
|
-- Networks has been advised of, known, or should have known, the
|
|
-- possibility of such damages.
|
|
--
|
|
-- Enterasys Networks grants vendors, end-users, and other interested
|
|
-- parties a non-exclusive license to use this Specification in
|
|
-- connection with the management of Enterasys Networks products.
|
|
|
|
-- Copyright 2002-2006 Enterasys Networks, Inc.
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Counter32
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, DateAndTime
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
InterfaceIndex
|
|
FROM IF-MIB
|
|
BridgeId, dot1dStpPortEntry, dot1dStpPort
|
|
FROM BRIDGE-MIB
|
|
etsysModules
|
|
FROM ENTERASYS-MIB-NAMES;
|
|
|
|
etsysSpanningTreeDiagnosticMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200610041949Z" -- Wed Oct 4 19:49 GMT 2006
|
|
ORGANIZATION "Enterasys Networks, Inc"
|
|
CONTACT-INFO
|
|
"Postal: Enterasys Networks
|
|
50 Minuteman Rd.
|
|
Andover, MA 01810-1008
|
|
USA
|
|
Phone: +1 978 684 1000
|
|
E-mail: support@enterasys.com
|
|
WWW: http://www.enterasys.com"
|
|
|
|
DESCRIPTION
|
|
"This MIB module defines a portion of the SNMP enterprise
|
|
MIBs under Enterasys Networks' enterprise OID pertaining to
|
|
the Spanning Tree Protocols IEEE 802.1D, 802.1w, and 802.1s."
|
|
|
|
REVISION "200610041949Z" -- Wed Oct 4 19:49 GMT 2006
|
|
DESCRIPTION
|
|
"Added an object specifying a disputed BPDU threshold value,
|
|
and added two disputed BPDU threshold exceeded notifications,
|
|
one for the CIST and one for MSTIs."
|
|
|
|
REVISION "200501241546Z" -- Mon Jan 24 15:46 GMT 2005
|
|
DESCRIPTION
|
|
"Changed references of dot1dBasePort to dot1dStpPort."
|
|
|
|
REVISION "200406071920Z" -- Mon Jun 7 19:20 GMT 2004
|
|
DESCRIPTION
|
|
"Added the etsysStpDiagCistBridgePortTable and
|
|
etsysStpDiagMstiBridgePortTable which are the
|
|
same as the etsysStpDiagCistPortTable and the
|
|
etsysStpDiagMstiPortTable but are index by
|
|
bridge port."
|
|
|
|
REVISION "200301151918Z" -- Wed Jan 15 19:18 GMT 2003
|
|
DESCRIPTION
|
|
"Added four objects to count the number of inferior BPDUs
|
|
received from a bridge port that incorrectly believes itself
|
|
to be the designated port."
|
|
|
|
REVISION "200211211901Z" -- Thu Nov 21 19:01 GMT 2002
|
|
DESCRIPTION
|
|
"Added four objects to count the reception and transmission
|
|
of IEEE 802.1D Configuration BPDUs with their Topology Change
|
|
flags set, both on a overall and on a per port basis.
|
|
Deprecated the etsysStpDiagMstiPortTopChanges object."
|
|
|
|
REVISION "200211182136Z" -- Mon Nov 18 21:36 GMT 2002
|
|
DESCRIPTION
|
|
"Added etsysStpDiagMstiPortNumber as an index to
|
|
etsysStpDiagMstiPortTable."
|
|
|
|
REVISION "200210102101Z" -- Thu Oct 10 21:01 GMT 2002
|
|
DESCRIPTION
|
|
"The initial version of this MIB module"
|
|
::= { etsysModules 29 }
|
|
|
|
|
|
-- -------------------------------------------------------------
|
|
-- Textual Conventions
|
|
-- -------------------------------------------------------------
|
|
|
|
EtsysStpPortRole ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the port role for RST and MST:
|
|
disabled - This port has no role.
|
|
root - This port has the role of root port.
|
|
designated - This port has the role of designated port.
|
|
alternate - This port has the role of alternate port.
|
|
backUp - This port has the role of backup port.
|
|
master - This port has the role of master port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 13.12"
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
root(2),
|
|
designated(3),
|
|
alternate(4),
|
|
backUp(5),
|
|
master(6)
|
|
}
|
|
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- branches in the ENTERASYS-SPANNING-TREE-DIAGNOSTIC-MIB
|
|
-- ---------------------------------------------------------- --
|
|
|
|
etsysStpDiagObjects OBJECT IDENTIFIER ::= { etsysSpanningTreeDiagnosticMIB 1 }
|
|
|
|
etsysStpDiagControl OBJECT IDENTIFIER ::= { etsysStpDiagObjects 1 }
|
|
etsysStpDiagCommon OBJECT IDENTIFIER ::= { etsysStpDiagObjects 2 }
|
|
etsysStpDiagCistPort OBJECT IDENTIFIER ::= { etsysStpDiagObjects 3 }
|
|
etsysStpDiagMsti OBJECT IDENTIFIER ::= { etsysStpDiagObjects 4 }
|
|
etsysStpDiagMstiPort OBJECT IDENTIFIER ::= { etsysStpDiagObjects 5 }
|
|
etsysStpDiagRootHistory OBJECT IDENTIFIER ::= { etsysStpDiagObjects 6 }
|
|
etsysStpDiagTrapConfig OBJECT IDENTIFIER ::= { etsysStpDiagObjects 7 }
|
|
etsysStpDiagNotifications OBJECT IDENTIFIER ::= { etsysStpDiagObjects 0 }
|
|
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- Spanning Tree diagnostic MIB control info
|
|
-- ---------------------------------------------------------- --
|
|
|
|
etsysStpDiagCounterReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOp(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reading this object always returns noOp(1). Writing the
|
|
value noOp(1) has no effect. Writing the value reset(2)
|
|
to this object will cause all of the counters in this MIB
|
|
module to be reset to zero. Zeroing the counters in this
|
|
MIB module MUST NOT effect the data presented in any other
|
|
MIB module. Zeroing the counters in this MIB module WILL
|
|
affect all users of this MIB module. It is expected that
|
|
this MIB module will be used by only one person at a time,
|
|
as counter resets will cause counter discontinuities for
|
|
all users."
|
|
::= { etsysStpDiagControl 1 }
|
|
|
|
etsysStpDiagCounterResetElapsedTime OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of seconds since the counters in this MIB module
|
|
were last reset to zero. If the counters have not been
|
|
reset to zero since the last initialization return the
|
|
number of seconds since the last initialization."
|
|
::= { etsysStpDiagControl 2 }
|
|
|
|
etsysStpDiagCounterResetDateAndTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date and time at which the counters in this MIB module
|
|
were last reset to zero. If the counters have not been
|
|
reset to zero since the last initialization return the
|
|
date and time of the last initialization."
|
|
::= { etsysStpDiagControl 3 }
|
|
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- Common and Internal Spanning Tree diagnostic info
|
|
-- ---------------------------------------------------------- --
|
|
|
|
etsysStpDiagTopChanges OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of topology changes. This is a shadow copy
|
|
of the dot1dStpTopChanges object from the IETF BRIDGE-MIB.
|
|
Zeroing this object MUST NOT affect dot1dStpTopChanges."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 12.8.1.1.3"
|
|
::= { etsysStpDiagCommon 1 }
|
|
|
|
etsysStpDiagCommonInvalidBpdu OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of invalid BPDUs received."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.4"
|
|
::= { etsysStpDiagCommon 2 }
|
|
|
|
etsysStpDiagCommonStpCfgBpduRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Configuration BPDUs received."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCommon 3 }
|
|
|
|
etsysStpDiagCommonStpCfgBpduTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Configuration BPDUs transmitted."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCommon 4 }
|
|
|
|
etsysStpDiagCommonStpTcnBpduRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Topology Change Notification
|
|
BPDUs received."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCommon 5 }
|
|
|
|
etsysStpDiagCommonStpTcnBpduTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Topology Change Notification
|
|
BPDUs transmitted."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCommon 6 }
|
|
|
|
etsysStpDiagCommonRstBpduRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1w BPDUs received."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.2"
|
|
::= { etsysStpDiagCommon 7 }
|
|
|
|
etsysStpDiagCommonRstBpduTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1w BPDUs transmitted."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.2"
|
|
::= { etsysStpDiagCommon 8 }
|
|
|
|
etsysStpDiagCommonRstTcRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1w BPDUs received with the
|
|
Topology Change flag set. These BPDUs are included
|
|
in the overall count of 802.1w BPDUs received in the
|
|
etsysStpDiagCommonRstBpduRx object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.2"
|
|
::= { etsysStpDiagCommon 9 }
|
|
|
|
etsysStpDiagCommonRstTcTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1w BPDUs transmitted with the
|
|
Topology Change flag set. These BPDUs are included
|
|
in the overall count of 802.1w BPDUs transmitted in
|
|
the etsysStpDiagCommonRstBpduTx object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.2"
|
|
::= { etsysStpDiagCommon 10 }
|
|
|
|
etsysStpDiagCommonMstBpduRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs received."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.3"
|
|
::= { etsysStpDiagCommon 11 }
|
|
|
|
etsysStpDiagCommonMstBpduTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs transmitted."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.3"
|
|
::= { etsysStpDiagCommon 12 }
|
|
|
|
etsysStpDiagCommonMstCistTcRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs received with the
|
|
Topology Change flag set in the CIST Flags field.
|
|
These BPDUs are included in the overall count of 802.1s
|
|
BPDUs received in the etsysStpDiagCommonMstBpduRx object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.3"
|
|
::= { etsysStpDiagCommon 13 }
|
|
|
|
etsysStpDiagCommonMstCistTcTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs transmitted with the
|
|
Topology Change flag set in the CIST Flags field.
|
|
These BPDUs are included in the overall count of 802.1s
|
|
BPDUs transmitted in the etsysStpDiagCommonMstBpduRx
|
|
object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.3"
|
|
::= { etsysStpDiagCommon 14 }
|
|
|
|
etsysStpDiagCommonStpCfgBpduRxTcFlagSet OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Configuration BPDUs received
|
|
with the Topology Change flag set. These BPDUs are included
|
|
in the overall count of 802.1D Configuration BPDUs received
|
|
in the etsysStpDiagCommonStpCfgBpduRx object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCommon 15 }
|
|
|
|
etsysStpDiagCommonStpCfgBpduTxTcFlagSet OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Configuration BPDUs transmitted
|
|
with the Topology Change flag set. These BPDUs are included
|
|
in the overall count of 802.1D Configuration BPDUs transmitted
|
|
in the etsysStpDiagCommonStpCfgBpduTx object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCommon 16 }
|
|
|
|
etsysStpDiagCommonDisputedBpdu OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of BPDUs received with inferior designated
|
|
information and that have the learning flag set. These
|
|
BPDU's may indicate the presence of a one way communication
|
|
path between adjacent bridge ports. They can also occur as
|
|
part of normal operation of a network, and may persist for a
|
|
while during power up."
|
|
REFERENCE
|
|
"IEEE DRAFT P802.1y/D4 clause 17.19.25"
|
|
::= { etsysStpDiagCommon 17 }
|
|
|
|
etsysStpDiagMessageExpiration OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times the BPDU message timer expired.
|
|
This indicates that BPDUs are not being received on
|
|
a regular basis."
|
|
::= { etsysStpDiagCommon 28 }
|
|
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- Common and Internal Spanning Tree per port diagnostic info
|
|
-- ---------------------------------------------------------- --
|
|
--
|
|
-- ---------------------------------------------------------- --
|
|
-- NOTE: This table is instanced by MIB-II interface number.
|
|
-- ---------------------------------------------------------- --
|
|
|
|
etsysStpDiagCistPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EtsysStpDiagCistPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains port level diagnostic information
|
|
indexed by its MIB-II interface number."
|
|
::= { etsysStpDiagCistPort 1 }
|
|
|
|
etsysStpDiagCistPortEntry OBJECT-TYPE
|
|
SYNTAX EtsysStpDiagCistPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of diagnostic information maintained for every port."
|
|
INDEX { etsysStpDiagCistPortNumber }
|
|
::= { etsysStpDiagCistPortTable 1 }
|
|
|
|
EtsysStpDiagCistPortEntry ::=
|
|
SEQUENCE {
|
|
etsysStpDiagCistPortNumber InterfaceIndex,
|
|
etsysStpDiagCistPortRole EtsysStpPortRole,
|
|
etsysStpDiagCistPortInvalidBpdu Counter32,
|
|
etsysStpDiagCistPortStpCfgBpduRx Counter32,
|
|
etsysStpDiagCistPortStpCfgBpduTx Counter32,
|
|
etsysStpDiagCistPortStpTcnBpduRx Counter32,
|
|
etsysStpDiagCistPortStpTcnBpduTx Counter32,
|
|
etsysStpDiagCistPortRstBpduRx Counter32,
|
|
etsysStpDiagCistPortRstBpduTx Counter32,
|
|
etsysStpDiagCistPortRstTcRx Counter32,
|
|
etsysStpDiagCistPortRstTcTx Counter32,
|
|
etsysStpDiagCistPortMstBpduRx Counter32,
|
|
etsysStpDiagCistPortMstBpduTx Counter32,
|
|
etsysStpDiagCistPortMstCistTcRx Counter32,
|
|
etsysStpDiagCistPortMstCistTcTx Counter32,
|
|
etsysStpDiagCistPortExpiration Counter32,
|
|
etsysStpDiagCistPortStpCfgBpduRxTcFlagSet Counter32,
|
|
etsysStpDiagCistPortStpCfgBpduTxTcFlagSet Counter32,
|
|
etsysStpDiagCistPortDisputedBpdu Counter32
|
|
}
|
|
|
|
etsysStpDiagCistPortNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MIB-II interface number of the port for which this entry
|
|
contains Spanning Tree Protocol diagnostic information."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 12.8.2"
|
|
::= { etsysStpDiagCistPortEntry 1 }
|
|
|
|
etsysStpDiagCistPortRole OBJECT-TYPE
|
|
SYNTAX EtsysStpPortRole
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the port role for this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 13.12"
|
|
::= { etsysStpDiagCistPortEntry 2 }
|
|
|
|
etsysStpDiagCistPortInvalidBpdu OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of invalid BPDUs received on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.4"
|
|
::= { etsysStpDiagCistPortEntry 3 }
|
|
|
|
etsysStpDiagCistPortStpCfgBpduRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Configuration BPDUs received
|
|
on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCistPortEntry 4 }
|
|
|
|
etsysStpDiagCistPortStpCfgBpduTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Configuration BPDUs transmitted
|
|
on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCistPortEntry 5 }
|
|
|
|
etsysStpDiagCistPortStpTcnBpduRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Topology Change Notification
|
|
BPDUs received on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCistPortEntry 6 }
|
|
|
|
etsysStpDiagCistPortStpTcnBpduTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Topology Change Notification
|
|
BPDUs transmitted on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCistPortEntry 7 }
|
|
|
|
etsysStpDiagCistPortRstBpduRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1w BPDUs received on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.2"
|
|
::= { etsysStpDiagCistPortEntry 8 }
|
|
|
|
etsysStpDiagCistPortRstBpduTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1w BPDUs transmitted on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.2"
|
|
::= { etsysStpDiagCistPortEntry 9 }
|
|
|
|
etsysStpDiagCistPortRstTcRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1w BPDUs received on this port
|
|
with the Topology Change flag set. These BPDUs are
|
|
included in the overall count of 802.1w BPDUs received
|
|
in the etsysStpDiagCistPortRstBpduRx object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.2"
|
|
::= { etsysStpDiagCistPortEntry 10 }
|
|
|
|
etsysStpDiagCistPortRstTcTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1w BPDUs transmitted on this
|
|
port with the Topology Change flag set. These BPDUs
|
|
are included in the overall count of 802.1w BPDUs
|
|
transmitted in the etsysStpDiagCistPortRstBpduTx object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.2"
|
|
::= { etsysStpDiagCistPortEntry 11 }
|
|
|
|
etsysStpDiagCistPortMstBpduRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs received on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.3"
|
|
::= { etsysStpDiagCistPortEntry 12 }
|
|
|
|
etsysStpDiagCistPortMstBpduTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs transmitted on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.3"
|
|
::= { etsysStpDiagCistPortEntry 13 }
|
|
|
|
etsysStpDiagCistPortMstCistTcRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs received on this port
|
|
with the Topology Change flag set in the CIST Flags field.
|
|
These BPDUs are included in the overall count of 802.1s
|
|
BPDUs received in the etsysStpDiagCistPortMstBpduRx object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.3"
|
|
::= { etsysStpDiagCistPortEntry 14 }
|
|
|
|
etsysStpDiagCistPortMstCistTcTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs transmitted on this port
|
|
with the Topology Change flag set in the CIST Flags field.
|
|
These BPDUs are included in the overall count of 802.1s
|
|
BPDUs transmitted in the etsysStpDiagCistPortMstBpduRx object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.3"
|
|
::= { etsysStpDiagCistPortEntry 15 }
|
|
|
|
etsysStpDiagCistPortExpiration OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times the BPDU message timer expired.
|
|
This indicates that BPDUs are not being received on
|
|
a regular basis."
|
|
::= { etsysStpDiagCistPortEntry 16 }
|
|
|
|
etsysStpDiagCistPortStpCfgBpduRxTcFlagSet OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Configuration BPDUs received
|
|
on this port with the Topology Change flag set. These BPDUs
|
|
are included in the overall count of 802.1D Configuration
|
|
BPDUs received in the etsysStpDiagCistPortStpCfgBpduRx
|
|
object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCistPortEntry 17 }
|
|
|
|
etsysStpDiagCistPortStpCfgBpduTxTcFlagSet OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Configuration BPDUs transmitted
|
|
on this port with the Topology Change flag set. These BPDUs
|
|
are included in the overall count of 802.1D Configuration
|
|
BPDUs transmitted in the etsysStpDiagCistPortStpCfgBpduRx
|
|
object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCistPortEntry 18 }
|
|
|
|
etsysStpDiagCistPortDisputedBpdu OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of BPDUs received on this port with inferior
|
|
designated information and that have the learning flag set.
|
|
These BPDU's may indicate the presence of a one way
|
|
communication path between adjacent bridge ports. They can
|
|
also occur as part of normal operation of a network, and may
|
|
persist for a while during power up."
|
|
REFERENCE
|
|
"IEEE DRAFT P802.1y/D4 clause 17.19.25"
|
|
::= { etsysStpDiagCistPortEntry 19 }
|
|
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- Common and Internal Spanning Tree per bridge port diag info
|
|
-- ---------------------------------------------------------- --
|
|
--
|
|
-- ---------------------------------------------------------- --
|
|
-- NOTE: This table augments dot1dStpPortEntry
|
|
-- ---------------------------------------------------------- --
|
|
|
|
etsysStpDiagCistBridgePortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EtsysStpDiagCistBridgePortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains port level diagnostic information
|
|
indexed by bridge port."
|
|
::= { etsysStpDiagCistPort 2 }
|
|
|
|
etsysStpDiagCistBridgePortEntry OBJECT-TYPE
|
|
SYNTAX EtsysStpDiagCistBridgePortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of diagnostic information maintained for every port."
|
|
AUGMENTS { dot1dStpPortEntry }
|
|
::= { etsysStpDiagCistBridgePortTable 1 }
|
|
|
|
EtsysStpDiagCistBridgePortEntry ::=
|
|
SEQUENCE {
|
|
etsysStpDiagCistBridgePortRole EtsysStpPortRole,
|
|
etsysStpDiagCistBridgePortInvalidBpdu Counter32,
|
|
etsysStpDiagCistBridgePortStpCfgBpduRx Counter32,
|
|
etsysStpDiagCistBridgePortStpCfgBpduTx Counter32,
|
|
etsysStpDiagCistBridgePortStpTcnBpduRx Counter32,
|
|
etsysStpDiagCistBridgePortStpTcnBpduTx Counter32,
|
|
etsysStpDiagCistBridgePortRstBpduRx Counter32,
|
|
etsysStpDiagCistBridgePortRstBpduTx Counter32,
|
|
etsysStpDiagCistBridgePortRstTcRx Counter32,
|
|
etsysStpDiagCistBridgePortRstTcTx Counter32,
|
|
etsysStpDiagCistBridgePortMstBpduRx Counter32,
|
|
etsysStpDiagCistBridgePortMstBpduTx Counter32,
|
|
etsysStpDiagCistBridgePortMstCistTcRx Counter32,
|
|
etsysStpDiagCistBridgePortMstCistTcTx Counter32,
|
|
etsysStpDiagCistBridgePortExpiration Counter32,
|
|
etsysStpDiagCistBridgePortStpCfgBpduRxTcFlagSet Counter32,
|
|
etsysStpDiagCistBridgePortStpCfgBpduTxTcFlagSet Counter32,
|
|
etsysStpDiagCistBridgePortDisputedBpdu Counter32
|
|
}
|
|
|
|
etsysStpDiagCistBridgePortRole OBJECT-TYPE
|
|
SYNTAX EtsysStpPortRole
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the port role for this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 13.12"
|
|
::= { etsysStpDiagCistBridgePortEntry 2 }
|
|
|
|
etsysStpDiagCistBridgePortInvalidBpdu OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of invalid BPDUs received on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.4"
|
|
::= { etsysStpDiagCistBridgePortEntry 3 }
|
|
|
|
etsysStpDiagCistBridgePortStpCfgBpduRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Configuration BPDUs received
|
|
on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCistBridgePortEntry 4 }
|
|
|
|
etsysStpDiagCistBridgePortStpCfgBpduTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Configuration BPDUs transmitted
|
|
on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCistBridgePortEntry 5 }
|
|
|
|
etsysStpDiagCistBridgePortStpTcnBpduRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Topology Change Notification
|
|
BPDUs received on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCistBridgePortEntry 6 }
|
|
|
|
etsysStpDiagCistBridgePortStpTcnBpduTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Topology Change Notification
|
|
BPDUs transmitted on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCistBridgePortEntry 7 }
|
|
|
|
etsysStpDiagCistBridgePortRstBpduRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1w BPDUs received on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.2"
|
|
::= { etsysStpDiagCistBridgePortEntry 8 }
|
|
|
|
etsysStpDiagCistBridgePortRstBpduTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1w BPDUs transmitted on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.2"
|
|
::= { etsysStpDiagCistBridgePortEntry 9 }
|
|
|
|
etsysStpDiagCistBridgePortRstTcRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1w BPDUs received on this port
|
|
with the Topology Change flag set. These BPDUs are
|
|
included in the overall count of 802.1w BPDUs received
|
|
in the etsysStpDiagCistPBridgeortRstBpduRx object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.2"
|
|
::= { etsysStpDiagCistBridgePortEntry 10 }
|
|
|
|
etsysStpDiagCistBridgePortRstTcTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1w BPDUs transmitted on this
|
|
port with the Topology Change flag set. These BPDUs
|
|
are included in the overall count of 802.1w BPDUs
|
|
transmitted in the etsysStpDiagCistBridgePortRstBpduTx object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.2"
|
|
::= { etsysStpDiagCistBridgePortEntry 11 }
|
|
|
|
etsysStpDiagCistBridgePortMstBpduRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs received on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.3"
|
|
::= { etsysStpDiagCistBridgePortEntry 12 }
|
|
|
|
etsysStpDiagCistBridgePortMstBpduTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs transmitted on this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.3"
|
|
::= { etsysStpDiagCistBridgePortEntry 13 }
|
|
|
|
etsysStpDiagCistBridgePortMstCistTcRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs received on this port
|
|
with the Topology Change flag set in the CIST Flags field.
|
|
These BPDUs are included in the overall count of 802.1s
|
|
BPDUs received in the etsysStpDiagCistBridgePortMstBpduRx object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.3"
|
|
::= { etsysStpDiagCistBridgePortEntry 14 }
|
|
|
|
etsysStpDiagCistBridgePortMstCistTcTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs transmitted on this port
|
|
with the Topology Change flag set in the CIST Flags field.
|
|
These BPDUs are included in the overall count of 802.1s
|
|
BPDUs transmitted in the etsysStpDiagCistBridgePortMstBpduRx object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.3"
|
|
::= { etsysStpDiagCistBridgePortEntry 15 }
|
|
|
|
etsysStpDiagCistBridgePortExpiration OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times the BPDU message timer expired.
|
|
This indicates that BPDUs are not being received on
|
|
a regular basis."
|
|
::= { etsysStpDiagCistBridgePortEntry 16 }
|
|
|
|
etsysStpDiagCistBridgePortStpCfgBpduRxTcFlagSet OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Configuration BPDUs received
|
|
on this port with the Topology Change flag set. These BPDUs
|
|
are included in the overall count of 802.1D Configuration
|
|
BPDUs received in the etsysStpDiagCistBridgePortStpCfgBpduRx
|
|
object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCistBridgePortEntry 17 }
|
|
|
|
etsysStpDiagCistBridgePortStpCfgBpduTxTcFlagSet OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1D Configuration BPDUs transmitted
|
|
on this port with the Topology Change flag set. These BPDUs
|
|
are included in the overall count of 802.1D Configuration
|
|
BPDUs transmitted in the etsysStpDiagCistBridgePortStpCfgBpduRx
|
|
object."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.3.1"
|
|
::= { etsysStpDiagCistBridgePortEntry 18 }
|
|
|
|
etsysStpDiagCistBridgePortDisputedBpdu OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of BPDUs received on this port with inferior
|
|
designated information and that have the learning flag set.
|
|
These BPDU's may indicate the presence of a one way
|
|
communication path between adjacent bridge ports. They can
|
|
also occur as part of normal operation of a network, and may
|
|
persist for a while during power up."
|
|
REFERENCE
|
|
"IEEE DRAFT P802.1y/D4 clause 17.19.25"
|
|
::= { etsysStpDiagCistBridgePortEntry 19 }
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- Multiple Spanning Tree Instance diagnostic info
|
|
-- ---------------------------------------------------------- --
|
|
|
|
etsysStpDiagMstiTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EtsysStpDiagMstiEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains diagnostic information for each
|
|
IEEE 802.1s Multiple Spanning Tree Instance."
|
|
::= { etsysStpDiagMsti 1 }
|
|
|
|
etsysStpDiagMstiEntry OBJECT-TYPE
|
|
SYNTAX EtsysStpDiagMstiEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of diagnostic information for each IEEE 802.1s
|
|
Multiple Spanning Tree Instance that is configured."
|
|
INDEX { etsysStpDiagMstiId }
|
|
::= { etsysStpDiagMstiTable 1 }
|
|
|
|
EtsysStpDiagMstiEntry ::=
|
|
SEQUENCE {
|
|
etsysStpDiagMstiId Unsigned32,
|
|
etsysStpDiagMstiTopChanges Counter32,
|
|
etsysStpDiagMstiConfigMsgRx Counter32,
|
|
etsysStpDiagMstiConfigMsgTx Counter32,
|
|
etsysStpDiagMstiTcRx Counter32,
|
|
etsysStpDiagMstiTcTx Counter32,
|
|
etsysStpDiagMstiDisputedBpdu Counter32
|
|
}
|
|
|
|
etsysStpDiagMstiId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4094)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique ID of this Multiple Spanning Tree instance.
|
|
The CIST (common and internal spanning tree) is not
|
|
represented in this table. There are a maximum of
|
|
sixty-four MSTIs, each with a unique identifier in
|
|
the range of 1-4094."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 12.8.1.2.2"
|
|
::= { etsysStpDiagMstiEntry 1 }
|
|
|
|
etsysStpDiagMstiTopChanges OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of topology changes detected on
|
|
this Mulitple Spanning Tree Instance."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 12.8.1.2.3"
|
|
::= { etsysStpDiagMstiEntry 2 }
|
|
|
|
etsysStpDiagMstiConfigMsgRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs received with MSTI
|
|
Configuration Messages for this MSTI."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.6.1"
|
|
::= { etsysStpDiagMstiEntry 3 }
|
|
|
|
etsysStpDiagMstiConfigMsgTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs transmitted with MSTI
|
|
Configuration Messages for this MSTI."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.6.1"
|
|
::= { etsysStpDiagMstiEntry 4 }
|
|
|
|
etsysStpDiagMstiTcRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs received with MSTI
|
|
Configuration Messages for this MSTI that had the
|
|
Topology Change flag set in the MSTI Flags field."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.6.1"
|
|
::= { etsysStpDiagMstiEntry 5 }
|
|
|
|
etsysStpDiagMstiTcTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs transmitted with MSTI
|
|
Configuration Messages for this MSTI that had the
|
|
Topology Change flag set in the MSTI Flags field."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.6.1"
|
|
::= { etsysStpDiagMstiEntry 6 }
|
|
|
|
etsysStpDiagMstiDisputedBpdu OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of BPDUs received on this MSTI with inferior
|
|
designated information and that have the learning flag set.
|
|
These BPDU's may indicate the presence of a one way
|
|
communication path between adjacent bridge ports. They can
|
|
also occur as part of normal operation of a network, and may
|
|
persist for a while during power up."
|
|
REFERENCE
|
|
"IEEE DRAFT P802.1y/D4 clause 17.19.25"
|
|
::= { etsysStpDiagMstiEntry 7 }
|
|
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- Multiple Spanning Tree Instance per port diagnostic info
|
|
-- ---------------------------------------------------------- --
|
|
--
|
|
-- ---------------------------------------------------------- --
|
|
-- NOTE: This table is instanced by MIB-II interface number.
|
|
-- ---------------------------------------------------------- --
|
|
|
|
etsysStpDiagMstiPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EtsysStpDiagMstiPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains diagnostic information for each port
|
|
on every IEEE 802.1s Multiple Spanning Tree Instance."
|
|
::= { etsysStpDiagMstiPort 1 }
|
|
|
|
etsysStpDiagMstiPortEntry OBJECT-TYPE
|
|
SYNTAX EtsysStpDiagMstiPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of diagnostic information for each port on every IEEE
|
|
802.1s Multiple Spanning Tree Instance that is configured."
|
|
INDEX { etsysStpDiagMstiPortMstiId, etsysStpDiagMstiPortNumber }
|
|
::= { etsysStpDiagMstiPortTable 1 }
|
|
|
|
EtsysStpDiagMstiPortEntry ::=
|
|
SEQUENCE {
|
|
etsysStpDiagMstiPortMstiId Unsigned32,
|
|
etsysStpDiagMstiPortNumber InterfaceIndex,
|
|
etsysStpDiagMstiPortTopChanges Counter32,
|
|
etsysStpDiagMstiPortConfigMsgRx Counter32,
|
|
etsysStpDiagMstiPortConfigMsgTx Counter32,
|
|
etsysStpDiagMstiPortTcRx Counter32,
|
|
etsysStpDiagMstiPortTcTx Counter32,
|
|
etsysStpDiagMstiPortDisputedBpdu Counter32
|
|
}
|
|
|
|
etsysStpDiagMstiPortMstiId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4094)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique ID of this Multiple Spanning Tree instance.
|
|
The CIST (common and internal spanning tree) is not
|
|
represented in this table. There are a maximum of
|
|
sixty-four MSTIs, each with a unique identifier in
|
|
the range of 1-4094."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 12.8.1.2.2"
|
|
::= { etsysStpDiagMstiPortEntry 1 }
|
|
|
|
etsysStpDiagMstiPortNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number of the port for which this entry
|
|
contains Spanning Tree Protocol diagnostic information."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 12.8.2"
|
|
::= { etsysStpDiagMstiPortEntry 2 }
|
|
|
|
etsysStpDiagMstiPortTopChanges OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The total number of topology changes detected on this
|
|
Mulitple Spanning Tree Instance and port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 12.8.1.1.3"
|
|
::= { etsysStpDiagMstiPortEntry 3 }
|
|
|
|
etsysStpDiagMstiPortConfigMsgRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs received with MSTI
|
|
Configuration Messages for this MSTI and port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.6.1"
|
|
::= { etsysStpDiagMstiPortEntry 4 }
|
|
|
|
etsysStpDiagMstiPortConfigMsgTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs transmitted with MSTI
|
|
Configuration Messages for this MSTI and port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.6.1"
|
|
::= { etsysStpDiagMstiPortEntry 5 }
|
|
|
|
etsysStpDiagMstiPortTcRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs received with MSTI
|
|
Configuration Messages for this MSTI and port that had
|
|
the Topology Change flag set in the MSTI Flags field."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.6.1"
|
|
::= { etsysStpDiagMstiPortEntry 6 }
|
|
|
|
etsysStpDiagMstiPortTcTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs transmitted with MSTI
|
|
Configuration Messages for this MSTI and port that had
|
|
the Topology Change flag set in the MSTI Flags field."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.6.1"
|
|
::= { etsysStpDiagMstiPortEntry 7 }
|
|
|
|
etsysStpDiagMstiPortDisputedBpdu OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of BPDUs received on this MSTI and port
|
|
with inferior designated information that have the learning
|
|
flag set. These BPDU's may indicate the presence of a one
|
|
way communication path between adjacent bridge ports. They
|
|
can also occur as part of normal operation of a network,
|
|
and may persist for a while during power up."
|
|
REFERENCE
|
|
"IEEE DRAFT P802.1y/D4 clause 17.19.25"
|
|
::= { etsysStpDiagMstiPortEntry 8 }
|
|
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- Multiple Spanning Tree Instance per port diagnostic info
|
|
-- ---------------------------------------------------------- --
|
|
--
|
|
-- ---------------------------------------------------------- --
|
|
-- NOTE: This table is instanced by MSTI Id and bridge port.
|
|
-- ---------------------------------------------------------- --
|
|
|
|
etsysStpDiagMstiBridgePortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EtsysStpDiagMstiBridgePortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains diagnostic information for each port
|
|
on every IEEE 802.1s Multiple Spanning Tree Instance."
|
|
::= { etsysStpDiagMstiPort 2 }
|
|
|
|
etsysStpDiagMstiBridgePortEntry OBJECT-TYPE
|
|
SYNTAX EtsysStpDiagMstiBridgePortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of diagnostic information for each port on every IEEE
|
|
802.1s Multiple Spanning Tree Instance that is configured."
|
|
INDEX { etsysStpDiagMstiBridgePortMstiId, dot1dStpPort }
|
|
::= { etsysStpDiagMstiBridgePortTable 1 }
|
|
|
|
EtsysStpDiagMstiBridgePortEntry ::=
|
|
SEQUENCE {
|
|
etsysStpDiagMstiBridgePortMstiId Unsigned32,
|
|
etsysStpDiagMstiBridgePortRole EtsysStpPortRole,
|
|
etsysStpDiagMstiBridgePortConfigMsgRx Counter32,
|
|
etsysStpDiagMstiBridgePortConfigMsgTx Counter32,
|
|
etsysStpDiagMstiBridgePortTcRx Counter32,
|
|
etsysStpDiagMstiBridgePortTcTx Counter32,
|
|
etsysStpDiagMstiBridgePortDisputedBpdu Counter32
|
|
}
|
|
|
|
etsysStpDiagMstiBridgePortMstiId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4094)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique ID of this Multiple Spanning Tree instance.
|
|
The CIST (common and internal spanning tree) is not
|
|
represented in this table. There are a maximum of
|
|
sixty-four MSTIs, each with a unique identifier in
|
|
the range of 1-4094."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 12.8.1.2.2"
|
|
::= { etsysStpDiagMstiBridgePortEntry 1 }
|
|
|
|
etsysStpDiagMstiBridgePortRole OBJECT-TYPE
|
|
SYNTAX EtsysStpPortRole
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the port role for this port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 13.12"
|
|
::= { etsysStpDiagMstiBridgePortEntry 3 }
|
|
|
|
etsysStpDiagMstiBridgePortConfigMsgRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs received with MSTI
|
|
Configuration Messages for this MSTI and port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.6.1"
|
|
::= { etsysStpDiagMstiBridgePortEntry 4 }
|
|
|
|
etsysStpDiagMstiBridgePortConfigMsgTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs transmitted with MSTI
|
|
Configuration Messages for this MSTI and port."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.6.1"
|
|
::= { etsysStpDiagMstiBridgePortEntry 5 }
|
|
|
|
etsysStpDiagMstiBridgePortTcRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs received with MSTI
|
|
Configuration Messages for this MSTI and port that had
|
|
the Topology Change flag set in the MSTI Flags field."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.6.1"
|
|
::= { etsysStpDiagMstiBridgePortEntry 6 }
|
|
|
|
etsysStpDiagMstiBridgePortTcTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of 802.1s BPDUs transmitted with MSTI
|
|
Configuration Messages for this MSTI and port that had
|
|
the Topology Change flag set in the MSTI Flags field."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 14.6.1"
|
|
::= { etsysStpDiagMstiBridgePortEntry 7 }
|
|
|
|
etsysStpDiagMstiBridgePortDisputedBpdu OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of BPDUs received on this MSTI and port
|
|
with inferior designated information that have the learning
|
|
flag set. These BPDU's may indicate the presence of a one
|
|
way communication path between adjacent bridge ports. They
|
|
can also occur as part of normal operation of a network,
|
|
and may persist for a while during power up."
|
|
REFERENCE
|
|
"IEEE DRAFT P802.1y/D4 clause 17.19.25"
|
|
::= { etsysStpDiagMstiBridgePortEntry 8 }
|
|
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- Spanning tree root history info
|
|
-- ---------------------------------------------------------- --
|
|
|
|
etsysStpDiagRootHistoryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EtsysStpDiagRootHistoryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains a short history of the spanning tree
|
|
root bridges."
|
|
::= { etsysStpDiagRootHistory 1 }
|
|
|
|
etsysStpDiagRootHistoryEntry OBJECT-TYPE
|
|
SYNTAX EtsysStpDiagRootHistoryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date and time that a particular bridge became the root."
|
|
INDEX { etsysStpDiagRootHistoryStpID, etsysStpDiagRootHistoryIndex }
|
|
::= { etsysStpDiagRootHistoryTable 1 }
|
|
|
|
EtsysStpDiagRootHistoryEntry ::=
|
|
SEQUENCE {
|
|
etsysStpDiagRootHistoryStpID Unsigned32,
|
|
etsysStpDiagRootHistoryIndex Unsigned32,
|
|
etsysStpDiagRootHistoryBridgeID BridgeId,
|
|
etsysStpDiagRootHistoryDateAndTime DateAndTime
|
|
}
|
|
|
|
etsysStpDiagRootHistoryStpID OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..4094)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique ID of this Spanning Tree instance. The
|
|
value zero represents the CIST. There are a maximum
|
|
of sixty-four MSTIs, each with a unique identifier in
|
|
the range of 1-4094."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clause 12.8.1.2.2"
|
|
::= { etsysStpDiagRootHistoryEntry 1 }
|
|
|
|
etsysStpDiagRootHistoryIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..10)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index for the root bridge entry. The index value of
|
|
one represents the most recent entry, and the value of
|
|
ten represents the oldest entry."
|
|
::= { etsysStpDiagRootHistoryEntry 2 }
|
|
|
|
etsysStpDiagRootHistoryBridgeID OBJECT-TYPE
|
|
SYNTAX BridgeId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bridge identifier of the bridge that this entry
|
|
represents."
|
|
REFERENCE
|
|
"IEEE P802.1s/D15 clauses 12.8.1.1.3 and 12.8.1.2.3"
|
|
::= { etsysStpDiagRootHistoryEntry 3 }
|
|
|
|
etsysStpDiagRootHistoryDateAndTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date and time that this bridge became root."
|
|
::= { etsysStpDiagRootHistoryEntry 4 }
|
|
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- Trap configuration
|
|
-- ---------------------------------------------------------- --
|
|
|
|
etsysStpDiagDisputedBpduTrapThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of disputed BPDUs that must be received on a
|
|
particular port on a particular Spanning Tree instance before
|
|
a disputed BPDU notification is generated. If a notification
|
|
has been previously generated on behalf of this port/instance,
|
|
then this object represents the number of disputed BPDUs that
|
|
must be received since the prior notification before generating
|
|
a subsequent notification. Setting this object to zero will
|
|
cause generation of notifications to be disabled."
|
|
DEFVAL { 0 }
|
|
::= { etsysStpDiagTrapConfig 1 }
|
|
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- Notifications
|
|
-- ---------------------------------------------------------- --
|
|
|
|
etsysStpDiagCistDisputedBpduThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { dot1dStpPort, etsysStpDiagCistBridgePortDisputedBpdu }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the number of disputed
|
|
BPDUs received by a bridge port on the CIST since the previous
|
|
notification (if any) has exceeded the threshold defined
|
|
by etsysStpDiagDisputedBpduTrapThreshold."
|
|
::= { etsysStpDiagNotifications 1 }
|
|
|
|
etsysStpDiagMstiDisputedBpduThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS { etsysStpDiagMstiBridgePortMstiId, dot1dStpPort,
|
|
etsysStpDiagMstiBridgePortDisputedBpdu }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification indicates that the number of disputed
|
|
BPDUs received by a bridge port on an MSTI since the previous
|
|
notification (if any) has exceeded the threshold defined
|
|
by etsysStpDiagDisputedBpduTrapThreshold."
|
|
::= { etsysStpDiagNotifications 2 }
|
|
|
|
|
|
-- -------------------------------------------------------------
|
|
-- Conformance Information
|
|
-- -------------------------------------------------------------
|
|
|
|
etsysStpDiagConformance
|
|
OBJECT IDENTIFIER ::= { etsysSpanningTreeDiagnosticMIB 2 }
|
|
|
|
etsysStpDiagGroups
|
|
OBJECT IDENTIFIER ::= { etsysStpDiagConformance 1 }
|
|
|
|
etsysStpDiagCompliances
|
|
OBJECT IDENTIFIER ::= { etsysStpDiagConformance 2 }
|
|
|
|
|
|
-- -------------------------------------------------------------
|
|
-- Units of conformance
|
|
-- -------------------------------------------------------------
|
|
|
|
etsysStpDiagDot1dGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
etsysStpDiagCounterReset,
|
|
etsysStpDiagCounterResetElapsedTime,
|
|
etsysStpDiagCounterResetDateAndTime,
|
|
etsysStpDiagTopChanges,
|
|
etsysStpDiagCommonInvalidBpdu,
|
|
etsysStpDiagCommonStpCfgBpduRx,
|
|
etsysStpDiagCommonStpCfgBpduTx,
|
|
etsysStpDiagCommonStpTcnBpduRx,
|
|
etsysStpDiagCommonStpTcnBpduTx,
|
|
etsysStpDiagCommonStpCfgBpduRxTcFlagSet,
|
|
etsysStpDiagCommonStpCfgBpduTxTcFlagSet,
|
|
etsysStpDiagCommonDisputedBpdu,
|
|
etsysStpDiagMessageExpiration,
|
|
etsysStpDiagCistPortNumber,
|
|
etsysStpDiagCistPortRole,
|
|
etsysStpDiagCistPortInvalidBpdu,
|
|
etsysStpDiagCistPortStpCfgBpduRx,
|
|
etsysStpDiagCistPortStpCfgBpduTx,
|
|
etsysStpDiagCistPortStpTcnBpduRx,
|
|
etsysStpDiagCistPortStpTcnBpduTx,
|
|
etsysStpDiagCistPortStpCfgBpduRxTcFlagSet,
|
|
etsysStpDiagCistPortStpCfgBpduTxTcFlagSet,
|
|
etsysStpDiagCistPortDisputedBpdu,
|
|
etsysStpDiagCistPortExpiration
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing support for 802.1d
|
|
Spanning Tree Protocol diagnostics."
|
|
::= { etsysStpDiagGroups 1 }
|
|
|
|
etsysStpDiagDot1wGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
etsysStpDiagCommonRstBpduRx,
|
|
etsysStpDiagCommonRstBpduTx,
|
|
etsysStpDiagCommonRstTcRx,
|
|
etsysStpDiagCommonRstTcTx,
|
|
etsysStpDiagCistPortRstBpduRx,
|
|
etsysStpDiagCistPortRstBpduTx,
|
|
etsysStpDiagCistPortRstTcRx,
|
|
etsysStpDiagCistPortRstTcTx
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing support for 802.1w
|
|
Spanning Tree Protocol diagnostics."
|
|
::= { etsysStpDiagGroups 2 }
|
|
|
|
etsysStpDiagDot1sGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
etsysStpDiagCommonMstBpduRx,
|
|
etsysStpDiagCommonMstBpduTx,
|
|
etsysStpDiagCommonMstCistTcRx,
|
|
etsysStpDiagCommonMstCistTcTx,
|
|
etsysStpDiagCistPortMstBpduRx,
|
|
etsysStpDiagCistPortMstBpduTx,
|
|
etsysStpDiagCistPortMstCistTcRx,
|
|
etsysStpDiagCistPortMstCistTcTx,
|
|
etsysStpDiagCistBridgePortMstBpduRx,
|
|
etsysStpDiagCistBridgePortMstBpduTx,
|
|
etsysStpDiagCistBridgePortMstCistTcRx,
|
|
etsysStpDiagCistBridgePortMstCistTcTx,
|
|
etsysStpDiagMstiId,
|
|
etsysStpDiagMstiTopChanges,
|
|
etsysStpDiagMstiConfigMsgRx,
|
|
etsysStpDiagMstiConfigMsgTx,
|
|
etsysStpDiagMstiTcRx,
|
|
etsysStpDiagMstiTcTx,
|
|
etsysStpDiagMstiDisputedBpdu,
|
|
etsysStpDiagMstiPortMstiId,
|
|
etsysStpDiagMstiPortNumber,
|
|
etsysStpDiagMstiPortTopChanges,
|
|
etsysStpDiagMstiPortConfigMsgRx,
|
|
etsysStpDiagMstiPortConfigMsgTx,
|
|
etsysStpDiagMstiPortTcRx,
|
|
etsysStpDiagMstiPortTcTx,
|
|
etsysStpDiagMstiPortDisputedBpdu
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing support for 802.1s
|
|
Spanning Tree Protocol diagnostics."
|
|
::= { etsysStpDiagGroups 3 }
|
|
|
|
etsysStpDiagHistoryGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
etsysStpDiagRootHistoryStpID,
|
|
etsysStpDiagRootHistoryIndex,
|
|
etsysStpDiagRootHistoryBridgeID,
|
|
etsysStpDiagRootHistoryDateAndTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing historical root
|
|
bridge information."
|
|
::= { etsysStpDiagGroups 4 }
|
|
|
|
etsysStpDiagDot1dBridgePortGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
etsysStpDiagCistBridgePortRole,
|
|
etsysStpDiagCistBridgePortInvalidBpdu,
|
|
etsysStpDiagCistBridgePortStpCfgBpduRx,
|
|
etsysStpDiagCistBridgePortStpCfgBpduTx,
|
|
etsysStpDiagCistBridgePortStpTcnBpduRx,
|
|
etsysStpDiagCistBridgePortStpTcnBpduTx,
|
|
etsysStpDiagCistBridgePortStpCfgBpduRxTcFlagSet,
|
|
etsysStpDiagCistBridgePortStpCfgBpduTxTcFlagSet,
|
|
etsysStpDiagCistBridgePortDisputedBpdu,
|
|
etsysStpDiagCistBridgePortExpiration
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing per spanning tree level
|
|
support for Spanning Tree Protocol diagnostics."
|
|
::= { etsysStpDiagGroups 5 }
|
|
|
|
etsysStpDiagDot1wBridgePortGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
etsysStpDiagCistBridgePortRstBpduRx,
|
|
etsysStpDiagCistBridgePortRstBpduTx,
|
|
etsysStpDiagCistBridgePortRstTcRx,
|
|
etsysStpDiagCistBridgePortRstTcTx
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing per spanning tree level
|
|
support for Spanning Tree Protocol diagnostics."
|
|
::= { etsysStpDiagGroups 6 }
|
|
|
|
etsysStpDiagDot1sBridgePortGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
etsysStpDiagMstiBridgePortMstiId,
|
|
etsysStpDiagMstiBridgePortRole,
|
|
etsysStpDiagMstiBridgePortConfigMsgRx,
|
|
etsysStpDiagMstiBridgePortConfigMsgTx,
|
|
etsysStpDiagMstiBridgePortTcRx,
|
|
etsysStpDiagMstiBridgePortTcTx,
|
|
etsysStpDiagMstiBridgePortDisputedBpdu
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing support for 802.1s
|
|
Spanning Tree Protocol diagnostics."
|
|
::= { etsysStpDiagGroups 7 }
|
|
|
|
etsysStpDiagTrapConfigGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
etsysStpDiagDisputedBpduTrapThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing support for
|
|
configuration of Spanning Tree Protocol diagnostic
|
|
traps."
|
|
::= { etsysStpDiagGroups 8 }
|
|
|
|
etsysStpDiagNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
etsysStpDiagCistDisputedBpduThresholdExceeded,
|
|
etsysStpDiagMstiDisputedBpduThresholdExceeded
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of Spanning Tree Protocol diagnostic
|
|
notifications."
|
|
::= { etsysStpDiagGroups 9 }
|
|
|
|
|
|
-- -------------------------------------------------------------
|
|
-- Compliance statements
|
|
-- -------------------------------------------------------------
|
|
|
|
etsysStpDiagCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for devices that support the
|
|
Spanning Tree Diagnostic MIB."
|
|
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
etsysStpDiagDot1dGroup
|
|
}
|
|
|
|
GROUP etsysStpDiagDot1dBridgePortGroup
|
|
DESCRIPTION
|
|
"Bridge port based counters for IEEE 802.1d implementations."
|
|
|
|
GROUP etsysStpDiagDot1wGroup
|
|
DESCRIPTION
|
|
"Event counters for IEEE 802.1w implementations."
|
|
|
|
GROUP etsysStpDiagDot1wBridgePortGroup
|
|
DESCRIPTION
|
|
"Bridge port based counters for IEEE 802.1w implementations."
|
|
|
|
GROUP etsysStpDiagDot1sGroup
|
|
DESCRIPTION
|
|
"Event counters for IEEE 802.1s implementations."
|
|
|
|
GROUP etsysStpDiagDot1sBridgePortGroup
|
|
DESCRIPTION
|
|
"Bridge port based counters for IEEE 802.1s implementations."
|
|
|
|
GROUP etsysStpDiagHistoryGroup
|
|
DESCRIPTION
|
|
"Root bridge history information."
|
|
|
|
GROUP etsysStpDiagTrapConfigGroup
|
|
DESCRIPTION
|
|
"Trap configuration parameters."
|
|
|
|
GROUP etsysStpDiagNotificationGroup
|
|
DESCRIPTION
|
|
"Notifications."
|
|
|
|
::= { etsysStpDiagCompliances 1 }
|
|
|
|
END
|