<?php
require 'includes/graphs/common.inc.php';
$rrd_options .= " COMMENT:' Min Last Max\\n'";
$sensor['sensor_descr_fixed'] = rrdtool_escape($sensor['sensor_descr'], 23);
$rrd_options .= " DEF:sensor=$rrd_filename:sensor:AVERAGE";
$rrd_options .= " DEF:sensor_max=$rrd_filename:sensor:MAX";
$rrd_options .= " DEF:sensor_min=$rrd_filename:sensor:MIN";
$rrd_options .= " LINE1.5:sensor#cc0000:'".$sensor['sensor_descr_fixed']."'";
$rrd_options .= " GPRINT:sensor_min$current_id:MIN:%4.0lf";
$rrd_options .= ' GPRINT:sensor:LAST:%4.0lf';
$rrd_options .= ' GPRINT:sensor_max:MAX:%4.0lf\\l';
if (is_numeric($sensor['sensor_limit'])) {
$rrd_options .= ' HRULE:'.$sensor['sensor_limit'].'#999999::dashes';
}
if (is_numeric($sensor['sensor_limit_low'])) {
$rrd_options .= ' HRULE:'.$sensor['sensor_limit_low'].'#999999::dashes';
}