* refactor: advanced sensor states mark create_state_index($state_name) as E_USER_DEPRECATED? * fix: minor corrections * fix: mib has partialSync(9) and incompatibleVersion(8) * fix: corrected netagent2upsstate - Sleeping(5) * fix: NetAgent2 upsThreePhaseUPSStatusInverterOperating correction * refactor: array() be gone * Refactoring includes/discovery/sensors/state/extendair.inc.php with arrays And tidying up array formatting in other files * fix: minor typo * standardising array item names removed redundant "if ($state_index_id !== null) {" * workaround: procurve & serverscheck a sensor is causing create_state_index($state) to return null. The updated code doesn't allow for this and thus a hybrid is being used. * standardised naming of state info. Caused a typo $state_name instead of $status_name $state_name is the standard * converted compas to square arrays * Converted APC states using preg_match to new create_state_index() call * Update boss.inc.php
162 lines
12 KiB
PHP
162 lines
12 KiB
PHP
<?php
|
|
/*
|
|
* LibreNMS
|
|
*
|
|
* Copyright (c) 2018 Søren Friis Rosiak <sorenrosiak@gmail.com>
|
|
* This program is free software: you can redistribute it and/or modify it
|
|
* under the terms of the GNU General Public License as published by the
|
|
* Free Software Foundation, either version 3 of the License, or (at your
|
|
* option) any later version. Please see LICENSE.txt at the top level of
|
|
* the source code distribution for details.
|
|
*/
|
|
|
|
$role_data = snmpwalk_cache_oid($device, 'cswSwitchRole', [], 'CISCO-STACKWISE-MIB');
|
|
$redundant_data = snmp_get($device, "cswRingRedundant.0", "-OQv", "CISCO-STACKWISE-MIB");
|
|
|
|
$tables = [
|
|
['num_oid' => '.1.3.6.1.4.1.9.9.13.1.2.1.7.', 'oid' => 'ciscoEnvMonVoltageStatusTable', 'state_name' => 'ciscoEnvMonVoltageState', 'mib' => 'CISCO-ENVMON-MIB', 'descr' => 'ciscoEnvMonVoltageStatusDescr'],
|
|
['num_oid' => '.1.3.6.1.4.1.9.9.13.1.3.1.6.', 'oid' => 'ciscoEnvMonTemperatureStatusTable', 'state_name' => 'ciscoEnvMonTemperatureState', 'mib' => 'CISCO-ENVMON-MIB', 'descr' => 'ciscoEnvMonTemperatureStatusDescr'],
|
|
['num_oid' => '.1.3.6.1.4.1.9.9.13.1.4.1.3.', 'oid' => 'ciscoEnvMonFanStatusTable', 'state_name' => 'ciscoEnvMonFanState', 'mib' => 'CISCO-ENVMON-MIB', 'descr' => 'ciscoEnvMonFanStatusDescr'],
|
|
['num_oid' => '.1.3.6.1.4.1.9.9.13.1.5.1.3.', 'oid' => 'ciscoEnvMonSupplyStatusTable', 'state_name' => 'ciscoEnvMonSupplyState', 'mib' => 'CISCO-ENVMON-MIB', 'descr' => 'ciscoEnvMonSupplyStatusDescr'],
|
|
['num_oid' => '.1.3.6.1.4.1.9.9.117.1.1.2.1.2.', 'oid' => 'cefcFRUPowerStatusTable', 'state_name' => 'cefcFRUPowerOperStatus', 'mib' => 'CISCO-ENTITY-FRU-CONTROL-MIB', 'descr' => 'Sensor Name'],
|
|
['num_oid' => '.1.3.6.1.4.1.9.9.176.1.1.2.', 'oid' => 'cRFStatusUnitState', 'state_name' => 'cRFStatusUnitState', 'mib' => 'CISCO-RF-MIB', 'descr' => 'VSS Device State'],
|
|
['num_oid' => '.1.3.6.1.4.1.9.9.176.1.1.4.', 'oid' => 'cRFStatusPeerUnitState', 'state_name' => 'cRFStatusPeerUnitState', 'mib' => 'CISCO-RF-MIB', 'descr' => 'VSS Peer State'],
|
|
['num_oid' => '.1.3.6.1.4.1.9.9.176.1.2.14.', 'oid' => 'cRFCfgRedundancyOperMode', 'state_name' => 'cRFCfgRedundancyOperMode', 'mib' => 'CISCO-RF-MIB', 'descr' => 'VSS Mode'],
|
|
['num_oid' => '.1.3.6.1.4.1.9.9.500.1.1.3.', 'oid' => 'cswGlobals', 'state_name' => 'cswRingRedundant', 'mib' => 'CISCO-STACKWISE-MIB', 'descr' => 'Stack Ring - Redundant'],
|
|
['num_oid' => '.1.3.6.1.4.1.9.9.500.1.2.1.1.3.', 'oid' => 'cswSwitchRole', 'state_name' => 'cswSwitchRole', 'mib' => 'CISCO-STACKWISE-MIB', 'descr' => 'Stack Role - Switch#'],
|
|
['num_oid' => '.1.3.6.1.4.1.9.9.500.1.2.1.1.6.', 'oid' => 'cswSwitchState', 'state_name' => 'cswSwitchState', 'mib' => 'CISCO-STACKWISE-MIB', 'descr' => 'Stack State - Switch#'],
|
|
['num_oid' => '.1.3.6.1.4.1.9.9.500.1.2.2.1.1.', 'oid' => 'cswStackPortOperStatus', 'state_name' => 'cswStackPortOperStatus', 'mib' => 'CISCO-STACKWISE-MIB', 'descr' => 'Stack Port Status - '],
|
|
];
|
|
|
|
foreach ($tables as $tablevalue) {
|
|
//Some switches on 15.x expose this information regardless if they are stacked or not, we try to mitigate that by doing the following.
|
|
if (($tablevalue['oid'] == 'cswGlobals' || $tablevalue['oid'] == 'cswSwitchRole' || $tablevalue['oid'] == 'cswSwitchState' || $tablevalue['oid'] == 'cswStackPortOperStatus') && $redundant_data == 'false' && count($role_data) == 1) {
|
|
continue;
|
|
}
|
|
|
|
$temp = snmpwalk_cache_multi_oid($device, $tablevalue['oid'], [], $tablevalue['mib']);
|
|
$cur_oid = $tablevalue['num_oid'];
|
|
|
|
if (is_array($temp)) {
|
|
if ($temp[0][$tablevalue['state_name']] == 'nonRedundant' || $temp[0]['cswMaxSwitchNum'] == '1') {
|
|
break;
|
|
}
|
|
|
|
//Create State Index
|
|
$state_name = $tablevalue['state_name'];
|
|
|
|
//Create State Translation
|
|
if ($state_name == 'cRFStatusUnitState' || $state_name == 'cRFStatusPeerUnitState') {
|
|
$states = [
|
|
['value' => 1, 'generic' => 3, 'graph' => 0, 'descr' => 'notKnown'],
|
|
['value' => 2, 'generic' => 0, 'graph' => 0, 'descr' => 'disabled'],
|
|
['value' => 3, 'generic' => 1, 'graph' => 0, 'descr' => 'initialization'],
|
|
['value' => 4, 'generic' => 1, 'graph' => 0, 'descr' => 'negotiation'],
|
|
['value' => 5, 'generic' => 1, 'graph' => 0, 'descr' => 'standbyCold'],
|
|
['value' => 6, 'generic' => 1, 'graph' => 0, 'descr' => 'standbyColdConfig'],
|
|
['value' => 7, 'generic' => 1, 'graph' => 0, 'descr' => 'standbyColdFileSys'],
|
|
['value' => 8, 'generic' => 1, 'graph' => 0, 'descr' => 'standbyColdBulk'],
|
|
['value' => 9, 'generic' => 0, 'graph' => 0, 'descr' => 'standbyHot'],
|
|
['value' => 10, 'generic' => 1, 'graph' => 0, 'descr' => 'activeFast'],
|
|
['value' => 11, 'generic' => 1, 'graph' => 0, 'descr' => 'activeDrain'],
|
|
['value' => 12, 'generic' => 1, 'graph' => 0, 'descr' => 'activePreconfig'],
|
|
['value' => 13, 'generic' => 1, 'graph' => 0, 'descr' => 'activePostconfig'],
|
|
['value' => 14, 'generic' => 0, 'graph' => 0, 'descr' => 'active'],
|
|
['value' => 15, 'generic' => 1, 'graph' => 0, 'descr' => 'activeExtraload'],
|
|
['value' => 16, 'generic' => 1, 'graph' => 0, 'descr' => 'activeHandback']
|
|
];
|
|
} elseif ($state_name == 'cRFCfgRedundancyOperMode') {
|
|
$states = [
|
|
['value' => 1, 'generic' => 0, 'graph' => 0, 'descr' => 'nonRedundant'],
|
|
['value' => 2, 'generic' => 0, 'graph' => 0, 'descr' => 'staticLoadShareNonRedundant'],
|
|
['value' => 3, 'generic' => 0, 'graph' => 0, 'descr' => 'dynamicLoadShareNonRedundant'],
|
|
['value' => 4, 'generic' => 0, 'graph' => 0, 'descr' => 'staticLoadShareRedundant'],
|
|
['value' => 5, 'generic' => 0, 'graph' => 0, 'descr' => 'dynamicLoadShareRedundant'],
|
|
['value' => 6, 'generic' => 0, 'graph' => 0, 'descr' => 'coldStandbyRedundant'],
|
|
['value' => 7, 'generic' => 0, 'graph' => 0, 'descr' => 'warmStandbyRedundant'],
|
|
['value' => 8, 'generic' => 0, 'graph' => 0, 'descr' => 'hotStandbyRedundant']
|
|
];
|
|
} elseif ($state_name == 'cswRingRedundant') {
|
|
$states = [
|
|
['value' => 1, 'generic' => 0, 'graph' => 0, 'descr' => 'true'],
|
|
['value' => 2, 'generic' => 2, 'graph' => 0, 'descr' => 'false']
|
|
];
|
|
} elseif ($state_name == 'cswSwitchRole') {
|
|
$states = [
|
|
['value' => 1, 'generic' => 0, 'graph' => 0, 'descr' => 'master'],
|
|
['value' => 2, 'generic' => 0, 'graph' => 0, 'descr' => 'member'],
|
|
['value' => 3, 'generic' => 0, 'graph' => 0, 'descr' => 'notMember'],
|
|
['value' => 4, 'generic' => 0, 'graph' => 0, 'descr' => 'standby']
|
|
];
|
|
} elseif ($state_name == 'cswSwitchState') {
|
|
$states = [
|
|
['value' => 1, 'generic' => 1, 'graph' => 0, 'descr' => 'waiting'],
|
|
['value' => 2, 'generic' => 1, 'graph' => 0, 'descr' => 'progressing'],
|
|
['value' => 3, 'generic' => 1, 'graph' => 0, 'descr' => 'added'],
|
|
['value' => 4, 'generic' => 0, 'graph' => 0, 'descr' => 'ready'],
|
|
['value' => 5, 'generic' => 2, 'graph' => 0, 'descr' => 'sdmMismatch'],
|
|
['value' => 6, 'generic' => 2, 'graph' => 0, 'descr' => 'verMismatch'],
|
|
['value' => 7, 'generic' => 2, 'graph' => 0, 'descr' => 'featureMismatch'],
|
|
['value' => 8, 'generic' => 2, 'graph' => 0, 'descr' => 'newMasterInit'],
|
|
['value' => 9, 'generic' => 1, 'graph' => 0, 'descr' => 'provisioned'],
|
|
['value' => 10, 'generic' => 2, 'graph' => 0, 'descr' => 'invalid'],
|
|
['value' => 11, 'generic' => 1, 'graph' => 0, 'descr' => 'removed']
|
|
];
|
|
} elseif ($state_name == 'cefcFRUPowerOperStatus') {
|
|
$states = [
|
|
['value' => 1, 'generic' => 2, 'graph' => 0, 'descr' => 'off (other)'],
|
|
['value' => 2, 'generic' => 0, 'graph' => 0, 'descr' => 'on'],
|
|
['value' => 3, 'generic' => 1, 'graph' => 0, 'descr' => 'off (admin)'],
|
|
['value' => 4, 'generic' => 2, 'graph' => 0, 'descr' => 'off (denied)'],
|
|
['value' => 5, 'generic' => 2, 'graph' => 0, 'descr' => 'off (environmental)'],
|
|
['value' => 6, 'generic' => 2, 'graph' => 0, 'descr' => 'off (temperature)'],
|
|
['value' => 7, 'generic' => 2, 'graph' => 0, 'descr' => 'off (fan)'],
|
|
['value' => 8, 'generic' => 2, 'graph' => 0, 'descr' => 'failed'],
|
|
['value' => 9, 'generic' => 1, 'graph' => 0, 'descr' => 'on (fan failed)'],
|
|
['value' => 10, 'generic' => 2, 'graph' => 0, 'descr' => 'off (cooling)'],
|
|
['value' => 11, 'generic' => 2, 'graph' => 0, 'descr' => 'off (connector rating)'],
|
|
['value' => 12, 'generic' => 1, 'graph' => 0, 'descr' => 'on (no inline power)']
|
|
];
|
|
} else {
|
|
$states = [
|
|
['value' => 1, 'generic' => 0, 'graph' => 0, 'descr' => 'normal'],
|
|
['value' => 2, 'generic' => 1, 'graph' => 0, 'descr' => 'warning'],
|
|
['value' => 3, 'generic' => 2, 'graph' => 0, 'descr' => 'critical'],
|
|
['value' => 4, 'generic' => 3, 'graph' => 0, 'descr' => 'shutdown'],
|
|
['value' => 5, 'generic' => 3, 'graph' => 0, 'descr' => 'notPresent'],
|
|
['value' => 6, 'generic' => 2, 'graph' => 0, 'descr' => 'notFunctioning']
|
|
];
|
|
}
|
|
create_state_index($state_name, $states);
|
|
|
|
foreach ($temp as $index => $entry) {
|
|
if ($tablevalue['state_name'] == 'ciscoEnvMonTemperatureState' && (empty($temp[$index][$tablevalue['descr']]))) {
|
|
d_echo('Invalid sensor, skipping..');
|
|
} else {
|
|
//Discover Sensors
|
|
$descr = ucwords($temp[$index][$tablevalue['descr']]);
|
|
if ($state_name == 'cRFStatusUnitState' || $state_name == 'cRFStatusPeerUnitState' || $state_name == 'cRFCfgRedundancyOperMode' || $state_name == 'cswRingRedundant') {
|
|
$descr = $tablevalue['descr'];
|
|
} elseif ($state_name == 'cswSwitchRole') {
|
|
$swrolenumber++;
|
|
$descr = $tablevalue['descr'] . $swrolenumber;
|
|
} elseif ($state_name == 'cswSwitchState') {
|
|
$swstatenumber++;
|
|
$descr = $tablevalue['descr'] . $swstatenumber;
|
|
} elseif ($state_name == 'cswStackPortOperStatus') {
|
|
$stack_port_descr = get_port_by_index_cache($device['device_id'], $index);
|
|
$descr = $tablevalue['descr'] . $stack_port_descr['ifDescr'];
|
|
} elseif ($state_name == 'cefcFRUPowerOperStatus') {
|
|
$descr = snmp_get($device, 'entPhysicalName.'.$index, '-Oqv', 'ENTITY-MIB');
|
|
}
|
|
discover_sensor($valid['sensor'], 'state', $device, $cur_oid.$index, $index, $state_name, $descr, 1, 1, null, null, null, null, $temp[$index][$tablevalue['state_name']], 'snmp', $index);
|
|
|
|
//Create Sensor To State Index
|
|
create_sensor_to_state_index($device, $state_name, $index);
|
|
}
|
|
}
|
|
}
|
|
}
|
|
|
|
unset($role_data, $redundant_data);
|