"wireless": {
|
|
"discovery": {
|
|
"wireless_sensors": [
|
|
{
|
|
"sensor_deleted": "0",
|
|
"sensor_class": "rssi",
|
|
"sensor_index": "0",
|
|
"sensor_type": "radwin",
|
|
"sensor_descr": "RSSI",
|
|
"sensor_divisor": "1",
|
|
"sensor_multiplier": "1",
|
|
"sensor_aggregator": "sum",
|
|
"sensor_current": "-150",
|
|
"sensor_prev": null,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": "1",
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_oids": "[\".1.3.6.1.4.1.4458.1000.1.1.51.7.0\"]"
|
|
},
|
|
{
|
|
"sensor_deleted": "0",
|
|
"sensor_class": "power",
|
|
"sensor_index": "0",
|
|
"sensor_type": "Radwin-Tx",
|
|
"sensor_descr": "Tx Power",
|
|
"sensor_divisor": "1",
|
|
"sensor_multiplier": "1",
|
|
"sensor_aggregator": "sum",
|
|
"sensor_current": "15",
|
|
"sensor_prev": null,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": "1",
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_oids": "[\".1.3.6.1.4.1.4458.1000.1.5.4.0\"]"
|
|
},
|
|
{
|
|
"sensor_deleted": "0",
|
|
"sensor_class": "power",
|
|
"sensor_index": "0",
|
|
"sensor_type": "Radwin-Rx",
|
|
"sensor_descr": "Rx Power",
|
|
"sensor_divisor": "1",
|
|
"sensor_multiplier": "1",
|
|
"sensor_aggregator": "sum",
|
|
"sensor_current": "-49",
|
|
"sensor_prev": null,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": "1",
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_oids": "[\".1.3.6.1.4.1.4458.1000.1.5.9.1.0\"]"
|
|
},
|
|
{
|
|
"sensor_deleted": "0",
|
|
"sensor_class": "distance",
|
|
"sensor_index": "0",
|
|
"sensor_type": "radwin",
|
|
"sensor_descr": "Link distance",
|
|
"sensor_divisor": "1000",
|
|
"sensor_multiplier": "1",
|
|
"sensor_aggregator": "sum",
|
|
"sensor_current": "0.15",
|
|
"sensor_prev": null,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": "1",
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_oids": "[\".1.3.6.1.4.1.4458.1000.1.5.29.0\"]"
|
|
}
|
|
]
|
|
},
|
|
"poller": {
|
|
"wireless_sensors": [
|
|
{
|
|
"sensor_deleted": "0",
|
|
"sensor_class": "rssi",
|
|
"sensor_index": "0",
|
|
"sensor_type": "radwin",
|
|
"sensor_descr": "RSSI",
|
|
"sensor_divisor": "1",
|
|
"sensor_multiplier": "1",
|
|
"sensor_aggregator": "sum",
|
|
"sensor_current": "-150",
|
|
"sensor_prev": "-150",
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": "1",
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_oids": "[\".1.3.6.1.4.1.4458.1000.1.1.51.7.0\"]"
|
|
},
|
|
{
|
|
"sensor_deleted": "0",
|
|
"sensor_class": "power",
|
|
"sensor_index": "0",
|
|
"sensor_type": "Radwin-Tx",
|
|
"sensor_descr": "Tx Power",
|
|
"sensor_divisor": "1",
|
|
"sensor_multiplier": "1",
|
|
"sensor_aggregator": "sum",
|
|
"sensor_current": "15",
|
|
"sensor_prev": "15",
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": "1",
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_oids": "[\".1.3.6.1.4.1.4458.1000.1.5.4.0\"]"
|
|
},
|
|
{
|
|
"sensor_deleted": "0",
|
|
"sensor_class": "power",
|
|
"sensor_index": "0",
|
|
"sensor_type": "Radwin-Rx",
|
|
"sensor_descr": "Rx Power",
|
|
"sensor_divisor": "1",
|
|
"sensor_multiplier": "1",
|
|
"sensor_aggregator": "sum",
|
|
"sensor_current": "-49",
|
|
"sensor_prev": "-49",
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": "1",
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_oids": "[\".1.3.6.1.4.1.4458.1000.1.5.9.1.0\"]"
|
|
},
|
|
{
|
|
"sensor_deleted": "0",
|
|
"sensor_class": "distance",
|
|
"sensor_index": "0",
|
|
"sensor_type": "radwin",
|
|
"sensor_descr": "Link distance",
|
|
"sensor_divisor": "1000",
|
|
"sensor_multiplier": "1",
|
|
"sensor_aggregator": "sum",
|
|
"sensor_current": "0.15",
|
|
"sensor_prev": "0.15",
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": "1",
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_oids": "[\".1.3.6.1.4.1.4458.1000.1.5.29.0\"]"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
}
|