-- File : MsTraps.mib
-- Description : Private MIB file for FibroLAN MetroStar I system traps
-- By : Tal Katz-Touaf
-- MIB Version : 2.2
-- MetroStar Version : 1.7.0/build 19
-- Date : May 24 , 2010
-- ==========================================================================
--
--
-- Copyright Fibrolan, 2010. All rights reserved.
--
-- Reproduction of this document is authorized on condition that this
-- copyright notice is included.
--Versions history:
--1.0.0 (28/11/02) - Initial version
--1.0.4 (18/02/03) - Name of PSU index changed; Name of slot index changed; Remote device overheat added; Remote device TP limk up/down added
--1.0.8 (10/04/03) - GBE link/SD traps added
--1.1.0 (21/05/03) - Vars indications added
--1.2.1 (08/12/03) - Chassis and link indexes added; Module index name changed
--1.2.2 (14/01/04) - Variables change; Remote LX traps removed
--1.2.3 (17/02/04) - MCM100-RL traps added
--1.2.5 (10/06/04) - Signal detected/lost trap added; Remote device redundant link traps added
--1.3.0b(25/07/04) - E1 traps added
--1.4.0b(01/12/04) - Descriptions rephrased; OFC traps added
--1.4.1d(28/03/05) - Variables change
--1.5.0b(08/09/05) - Temperature normal traps added; Remote UNI FO link traps added
-- not released: 1.5.2b() - SFP traps added
--1.6.0b(21/06/06) - Remote device FO signal detected/lost added; SFP traps changed and re-assigned
--1.6.0 (03/07/06) - Variables added
--1.6.2 (27/03/08) - Added trap severity object and variables. Traps descriptions revised. Traps version applicability added. Added MCM1000X-RL traps.
--1.7.0 (24/05/10) - Cannot manage remote device using old MA version trap added
FIBROLAN-MIB-MS-TRAPS DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE, enterprises FROM SNMPv2-SMI
TRAP-TYPE FROM RFC-1215
flMsChassisModuleNumber, flMsChassisChannelNumber, flMsChassisPsuIndex FROM FIBROLAN-MIB-METRO-STAR
flMcm1xxChannelExtMvPortDescription FROM FIBROLAN-MIB-MCM1xx
flLta41ma-V2PortNumber FROM FIBROLAN-MIB-LTA41MA
flMcm1000ChannelExtMvPortDescription FROM FIBROLAN-MIB-GBE-MCM1000
flMsMcm100xE1PortIndex, flMsMcm100xE1PortDescription FROM FIBROLAN-MIB-MCM100-xE1
flSfpDevicePortIndex FROM FIBROLAN-MIB-SFP;
fibrolan OBJECT IDENTIFIER ::= { enterprises 4467 }
fibrolanSNMP OBJECT IDENTIFIER ::= { fibrolan 100 }
flTrapSeverity OBJECT-TYPE
SYNTAX INTEGER {
off (0),
info (1),
warning (2),
error (3),
fatal (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Trap severity"
::= { fibrolanSNMP 1 }
-- *******************************************************
-- chassis level traps
-- *******************************************************
-- module traps
-- this trap is applicable from SW version 1.0.0 (initial version)
moduleInstalled TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity, flMsChassisModuleNumber }
DESCRIPTION
"New module installed.
Vars: trap severity, slot number"
::= 5000
-- this trap is applicable from SW version 1.0.0 (initial version)
moduleRemoved TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity, flMsChassisModuleNumber }
DESCRIPTION
"Module removed.
Vars: trap severity, slot number"
::= 5001
-- PSU traps
-- this trap is applicable from SW version 1.0.0 (initial version)
psuInstalled TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity, flMsChassisPsuIndex }
DESCRIPTION
"PSU module installed.
Vars: trap severity, PSU number"
::= 5010
-- this trap is applicable from SW version 1.0.0 (initial version)
psuRemoved TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity, flMsChassisPsuIndex }
DESCRIPTION
"PSU module removed.
Vars: trap severity, PSU number"
::= 5011
-- this trap is applicable from SW version 1.0.0 (initial version)
psuUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity, flMsChassisPsuIndex }
DESCRIPTION
"PSU module is up.
Vars: trap severity, PSU number"
::= 5012
-- this trap is applicable from SW version 1.0.0 (initial version)
psuDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity, flMsChassisPsuIndex }
DESCRIPTION
"PSU module is down.
Vars: trap severity, PSU number"
::= 5013
-- temperature trap
-- this trap is applicable from SW version 1.0.0 (initial version)
overHeat TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity }
DESCRIPTION
"Temperature higher than 65 degrees, for more than 1 minute.
Vars: trap severity"
::= 5020
-- this trap is applicable from SW version 1.5.0
temperatureNormal TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity }
DESCRIPTION
"Chassis temperature back to normal for more than 1 minute (clears over-heat alarm).
Vars: trap severity"
::= 5021
-- *******************************************************
-- module level traps
-- *******************************************************
-- remote device connection traps
-- this trap is applicable from SW version 1.0.0 (initial version)
remoteDeviceConnected TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"A new remote MA device has been connected and detected.
Vars: trap severity, slot number, channel number, channel description"
::= 5030
-- this trap is applicable from SW version 1.0.0 (initial version)
remoteDeviceDisconnected TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"A remote MA device has been disconnected.
Vars: trap severity, slot number, channel number, channel description"
::= 5031
-- this trap is applicable from SW version 1.0.0 (initial version)
remoteDevicePowerFail TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"A remote MA device had a power failure.
Vars: trap severity, slot number, channel number, channel description"
::= 5032
-- this trap is applicable from SW version 1.0.4
remoteDeviceOverHeat TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber }
DESCRIPTION
"Temperature in remote device is higher than 65 degrees, for more than 1 minute.
Vars: trap severity, slot number, channel number"
::= 5033
-- this trap is applicable from SW version 1.5.0
remoteDeviceTemperatureNormal TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber }
DESCRIPTION
"Remote device temperature back to normal for more than 1 minute (clears over-heat alarm).
Vars: trap severity, slot number, channel number"
::= 5034
-- local link state traps
-- this trap is applicable from SW version 1.0.0 (initial version)
tpLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Local (module) TP link down.
This trap is sent when a local module's TP port fails.
Vars: trap severity, slot number, channel number, channel description"
::= 5040
-- this trap is applicable from SW version 1.0.0 (initial version)
tpLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Local (module) TP link up.
This trap is sent when a local module's TP port's link is activated.
Vars: trap severity, slot number, channel number, channel description"
::= 5041
-- this trap is applicable from SW version 1.0.0 (initial version)
foLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Local (module) FO link down.
This trap is sent when a local module's FO port fails.
Applicable for all FE modules and for local FO SFP devices.
Vars: trap severity, slot number, channel number, channel description"
::= 5042
-- this trap is applicable from SW version 1.0.0 (initial version)
foLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Local (module) FO link up.
This trap is sent when a local module's FO port's link is activated.
Applicable for all FE modules and for local FO SFP devices.
Vars: trap severity, slot number, channel number, channel description"
::= 5043
-- this trap is applicable from SW version 1.2.5
signalLost TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Local (module) signal lost.
This trap is sent when a local module's FO port's signal is lost.
Applicable for MSM100U/MSM622U and for local FO SFP devices.
Vars: trap severity, slot number, port number, port description"
::= 5044
-- this trap is applicable from SW version 1.2.5
signalDetected TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Local (module) signal detected.
This trap is sent when a local module's FO port's signal is detected.
Applicable for MSM100U/MSM622U and for local FO SFP devices.
Vars: trap severity, slot number, port number, port description"
::= 5045
-- remote link state traps
-- this trap is applicable from SW version 1.0.4
remoteDeviceTpLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: TP link down.
This trap is sent when a remote devices's TP UNI port fails.
Applicable for FE and GE remote devices which has a TP UNI port and for remote TP UNI SFP devices.
Vars: trap severity, master slot number, channel number, channel description"
::= 5050
-- this trap is applicable from SW version 1.0.4
remoteDeviceTpLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: TP link up.
This trap is sent when a remote device's TP UNI port's link is activated.
Applicable for FE and GE remote devices which has a TP UNI port and for remote TP UNI SFP devices.
Vars: trap severity, master slot number, channel number, channel description"
::= 5051
-- this trap is applicable from SW version 1.5.0
remoteDeviceUniFoLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: UNI FO link down.
This trap is sent when a remote devices's FO UNI port fails.
Applicable for FCON1F/MA UNI port and for remote FO UNI SFP devices.
Vars: trap severity, master slot number, channel number, channel description"
::= 5052
-- this trap is applicable from SW version 1.5.0
remoteDeviceUniFoLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: UNI FO link up.
This trap is sent when a remote devices's FO UNI port's link is activated.
Applicable for FCON1F/MA UNI port and for remote FO UNI SFP devices.
Vars: trap severity, master slot number, channel number, channel description"
::= 5053
-- this trap is applicable from SW version 1.6.0
remoteDeviceUniFoSigLost TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: UNI FO signal lost.
This trap is sent when a remote device's FO UNI port's signal is lost.
Applicable for remote FO UNI SFP devices.
Vars: trap severity, master slot number, channel number, channel description"
::= 5054
-- this trap is applicable from SW version 1.6.0
remoteDeviceUniFoSigDetect TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: UNI FO signal detected.
This trap is sent when a remote device's FO UNI port's signal is detected.
Applicable for remote FO UNI SFP devices.
Vars: trap severity, master slot number, channel number, channel description"
::= 5055
-- remote link state traps (in multi-port devices)
-- this trap is applicable from SW version 1.0.0 (initial version)
remoteDeviceTpPortLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flLta41ma-V2PortNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: TP link down.
This trap is sent when a remote device's TP port fails.
Applicable for multiple TP ports devices, i.e LTA aggregators.
Vars: trap severity, master slot number, channel number, port number, port description"
::= 5060
-- this trap is applicable from SW version 1.0.0 (initial version)
remoteDeviceTpPortLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flLta41ma-V2PortNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: TP port link up.
This trap is sent when a remote device's TP port is activated.
Applicable for multiple TP ports devices, i.e LTA aggregators.
Vars: trap severity, master slot number, channel number, port number, port description"
::= 5061
-- GBE traps
-- local link/SD
-- this trap is applicable from SW version 1.0.8
lxLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local (module) LX link down.
This trap is sent when a local module's LX FO port fails.
Applicable for GE local modules, i.e MCM1000T, MCM1000S.
Vars: trap severity, slot number, channel number, channel description"
::= 5070
-- this trap is applicable from SW version 1.0.8
lxLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local (module) LX link up.
This trap is sent when a local module's LX FO port is activated.
Applicable for GE local modules, i.e MCM1000T, MCM1000S.
Vars: trap severity, slot number, channel number, channel description"
::= 5071
-- this trap is applicable from SW version 1.0.8
sxLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local (module) SX link down.
This trap is sent when a local module's SX FO port fails.
Applicable for GE local modules with 2 FO ports, i.e MCM1000S.
Vars: trap severity, slot number, channel number, channel description"
::= 5072
-- this trap is applicable from SW version 1.0.8
sxLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local (module) SX link up.
This trap is sent when a local module's SX FO port is activated.
Applicable for GE local modules with 2 FO ports, i.e MCM1000S.
Vars: trap severity, slot number, channel number, channel description"
::= 5073
-- this trap is applicable from SW version 1.0.8
lxSignalLost TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local (module) LX signal lost.
This trap is sent when a local module's LX FO port's signal is lost.
Applicable for GE local modules, i.e MCM1000T, MCM1000S.
Vars: trap severity, slot number, channel number, channel description"
::= 5074
-- this trap is applicable from SW version 1.0.8
lxSignalDetected TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local (module) LX signal detected.
This trap is sent when a local module's LX FO port's signal is detected.
Applicable for GE local modules, i.e MCM1000T, MCM1000S.
Vars: trap severity, slot number, channel number, channel description"
::= 5075
-- this trap is applicable from SW version 1.0.8
sxSignalLost TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local (module) SX signal lost.
This trap is sent when a local module's SX FO port's signal is lost.
Applicable for GE local modules with 2 FO ports, i.e MCM1000S.
Vars: trap severity, slot number, channel number, channel description"
::= 5076
-- this trap is applicable from SW version 1.0.8
sxSignalDetected TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local (module) SX signal detected.
This trap is sent when a local module's SX FO port's signal is detected.
Applicable for GE local modules with 2 FO ports, i.e MCM1000S.
Vars: trap severity, slot number, channel number, channel description"
::= 5077
-- remote link/SD
-- this trap is applicable from SW version 1.0.8
remoteSxLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Remote device: SX link down.
This trap is sent when a remote device's SX FO port fails.
Applicable for GE remote devices with 2 FO ports, i.e GSM1000/MA.
Vars: trap severity, slot number, channel number, channel description"
::= 5082
-- this trap is applicable from SW version 1.0.8
remoteSxLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Remote device: SX link up.
This trap is sent when a remote device's SX FO port is activated.
Applicable for GE remote devices with 2 FO ports, i.e GSM1000/MA.
Vars: trap severity, slot number, channel number, channel description"
::= 5083
-- this trap is applicable from SW version 1.0.8
remoteSxSignalLost TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Remote device: SX signal lost.
This trap is sent when a remote devicee's SX FO port's signal is lost.
Applicable for GE remote devices with 2 FO ports, i.e GSM1000/MA.
Vars: trap severity, slot number, channel number, channel description"
::= 5086
-- this trap is applicable from SW version 1.0.8
remoteSxSignalDetected TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Remote device: SX signal detected.
This trap is sent when a remote devicee's SX FO port's signal is detected.
Applicable for GE remote devices with 2 FO ports, i.e GSM1000/MA.
Vars: trap severity, slot number, channel number, channel description"
::= 5087
-- mcm100-rl
-- this trap is applicable from SW version 1.2.3
mainToBckpTpLink TRAP-TYPE -- Unused
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Switched from Main to Backup TP link.
Vars: trap severity, slot number"
::= 5088
-- this trap is applicable from SW version 1.2.3
bckpToMainTpLink TRAP-TYPE -- Unused
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Switched from Backup to Main TP link.
Vars: trap severity, slot number"
::= 5089
-- this trap is applicable from SW version 1.2.3
mainToBckpFoLink TRAP-TYPE -- Unused
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Switched from Main to Backup FO link.
Vars: trap severity, slot number"
::= 5090
-- this trap is applicable from SW version 1.2.3
bckpToMainFoLink TRAP-TYPE -- Unused
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Switched from Backup to Main FO link.
Vars: trap severity, slot number"
::= 5091
-- this trap is applicable from SW version 1.2.3
mainTpLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Main TP link up.
This trap is sent when a MCM100RL's main TP port is activated.
Vars: trap severity, slot number, port description"
::= 5092
-- this trap is applicable from SW version 1.2.3
mainTpLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber ,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Main TP link down.
This trap is sent when a MCM100RL's main TP port fails.
Vars: trap severity, slot number, port description"
::= 5093
-- this trap is applicable from SW version 1.2.3
mainFoLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Main Fo link up.
This trap is sent when a MCM100RL's main FO port is activated.
Vars: trap severity, slot number, port description"
::= 5094
-- this trap is applicable from SW version 1.2.3
mainFoLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Main Fo link down.
This trap is sent when a MCM100RL's main FO port fails.
Vars: trap severity, slot number, port description"
::= 5095
-- this trap is applicable from SW version 1.2.3
bckpTpLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Backup TP link up.
This trap is sent when a MCM100RL's backup TP port is activated.
Vars: trap severity, slot number, port description"
::= 5096
-- this trap is applicable from SW version 1.2.3
bckpTpLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Backup TP link down.
This trap is sent when a MCM100RL's backup TP port fails.
Vars: trap severity, slot number, port description"
::= 5097
-- this trap is applicable from SW version 1.2.3
bckpFoLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Backup FO link up.
This trap is sent when a MCM100RL's backup FO port is activated.
Vars: trap severity, slot number, port description"
::= 5098
-- this trap is applicable from SW version 1.2.3
bckpFoLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Backup FO link down.
This trap is sent when a MCM100RL's backup FO port fails.
Vars: trap severity, slot number, port description"
::= 5099
--mcm1000x-rl
-- this trap is applicable from SW version 1.6.2
mainToBckpLink TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1000xrlPortIndex }
DESCRIPTION
"Local Main to Backup link switchover.
This trap is sent when a MCM1000X-RL's main port link is switched to the backup port.
Vars: trap severity, slot number, port number"
::= 5100
-- this trap is applicable from SW version 1.6.2
bckpToMainLink TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1000xrlPortIndex }
DESCRIPTION
"Local Backup to Main link switchover.
This trap is sent when a MCM1000X-RL's backup port link is switched to the main port.
Vars: trap severity, slot number, port number"
::= 5101
-- this trap is applicable from SW version 1.6.2
mainTpSfpLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1000xrlPortIndex,
flMcm1000xrlChannelDescription }
DESCRIPTION
"Local Main TP SFP link up.
This trap is sent when a MCM1000X-RL's main TP SFP port is activated.
Vars: trap severity, slot number, port number, channel description"
::= 5110
-- this trap is applicable from SW version 1.6.2
mainTpSfpLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1000xrlPortIndex,
flMcm1000xrlChannelDescription }
DESCRIPTION
"Local Main TP link down.
This trap is sent when a MCM1000X-RL's main TP SFP port fails.
Vars: trap severity, slot number, port number, channel description"
::= 5111
-- this trap is applicable from SW version 1.6.2
mainFoSfpLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1000xrlPortIndex,
flMcm1000xrlChannelDescription }
DESCRIPTION
"Local Main Fo link up.
This trap is sent when a MCM1000X-RL's main FO SFP port is activated.
Vars: trap severity, slot number, port number, channel description"
::= 5112
-- this trap is applicable from SW version 1.6.2
mainFoSfpLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1000xrlPortIndex,
flMcm1000xrlChannelDescription }
DESCRIPTION
"Local Main Fo link down.
This trap is sent when a MCM1000X-RL's main FO SFP port fails.
Vars: trap severity, slot number, port number, channel description"
::= 5113
-- this trap is applicable from SW version 1.6.2
bckpTpSfpLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1000xrlPortIndex,
flMcm1000xrlChannelDescription }
DESCRIPTION
"Local Backup TP link up.
This trap is sent when a MCM1000X-RL's backup TP SFP port is activated.
Vars: trap severity, slot number, port number, channel description"
::= 5114
-- this trap is applicable from SW version 1.6.2
bckpTpSfpLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1000xrlPortIndex,
flMcm1000xrlChannelDescription }
DESCRIPTION
"Local Backup TP link down.
This trap is sent when a MCM1000X-RL's backup TP SFP port fails.
Vars: trap severity, slot number, port number, channel description"
::= 5115
-- this trap is applicable from SW version 1.6.2
bckpFoSfpLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1000xrlPortIndex,
flMcm1000xrlChannelDescription }
DESCRIPTION
"Local Backup FO link up.
This trap is sent when a MCM1000X-RL's backup FO SFP port is activated.
Vars: trap severity, slot number, port number, channel description"
::= 5116
-- this trap is applicable from SW version 1.6.2
bckpFoSfpLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1000xrlPortIndex,
flMcm1000xrlChannelDescription }
DESCRIPTION
"Local Backup FO link down.
This trap is sent when a MCM1000X-RL's backup FO SFP port fails.
Vars: trap severity, slot number, port number, channel description"
::= 5117
-- this trap is applicable from SW version 1.6.2
mainFoSfpSignalDetected TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1000xrlPortIndex,
flMcm1000xrlChannelDescription }
DESCRIPTION
"Local Main FO SFP signal detected.
This trap is sent when a MCM1000X-RL's main FO SFP port's signal is detected.
Vars: trap severity, slot number, port number, channel description"
::= 5120
-- this trap is applicable from SW version 1.6.2
mainFoSfpSignalLost TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1000xrlPortIndex,
flMcm1000xrlChannelDescription }
DESCRIPTION
"Local Main FO SFP signal lost.
This trap is sent when a MCM1000X-RL's main FO SFP port's signal is lost.
Vars: trap severity, slot number, port number, channel description"
::= 5121
-- this trap is applicable from SW version 1.6.2
bckpFoSfpSignalDetected TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1000xrlPortIndex,
flMcm1000xrlChannelDescription }
DESCRIPTION
"Local Backup FO SFP signal detected.
This trap is sent when a MCM1000X-RL's backup FO SFP port's signal is detected.
Vars: trap severity, slot number, port number, channel description"
::= 5122
-- this trap is applicable from SW version 1.6.2
bckpFoSfpSignalLost TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMcm1000xrlPortIndex,
flMcm1000xrlChannelDescription }
DESCRIPTION
"Local Backup FO SFP signal lost.
This trap is sent when a MCM1000X-RL's backup FO SFP port's signal is lost.
Vars: trap severity, slot number, port number, channel description"
::= 5123
--remote redundant link state
-- this trap is applicable from SW version 1.2.5
remoteDeviceBckpTpLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: Backup TP link up.
This trap is sent when a remote device's backup TP port is activated.
Applicable for all ATARA devices.
Vars: trap severity, master slot number, channel number, port description"
::= 5200
-- this trap is applicable from SW version 1.2.5
remoteDeviceBckpTpLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: Backup TP link down.
This trap is sent when a remote device's backup TP port fails.
Applicable for all ATARA devices.
Vars: trap severity, master slot number, channel number, port description"
::= 5201
-- this trap is applicable from SW version 1.2.5
remoteDeviceMainTpLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: Main TP link up.
This trap is sent when a remote device's main TP port is activated.
Applicable for all ATARA devices.
Vars: trap severity, master slot number, channel number, port description"
::= 5202
-- this trap is applicable from SW version 1.2.5
remoteDeviceMainTpLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: Main TP link down.
This trap is sent when a remote device's main TP port fails.
Applicable for all ATARA devices.
Vars: trap severity, master slot number, channel number, port description"
::= 5203
-- this trap is applicable from SW version 1.2.5
remoteDeviceBckp2MainFoLink TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: Backup to Main FO link.
This trap is sent when a remote device's FO port in use switch from backup to main.
Applicable for all ATARA devices.
Vars: trap severity, master slot number, channel number, port description"
::= 5204
-- this trap is applicable from SW version 1.2.5
remoteDeviceMain2BckpFoLink TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: Main to Backup FO link.
This trap is sent when a remote device's FO port in use switch from main to backup.
Applicable for all ATARA devices.
Vars: trap severity, master slot number, channel number, port description"
::= 5205
-- this trap is applicable from SW version 1.2.5
remoteDeviceBckpFoLinkUp TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: Backup FO link up.
This trap is sent when a remote device's backup FO port is activated.
Applicable for all ATARA devices.
Vars: trap severity, master slot number, channel number, port description"
::= 5206
-- this trap is applicable from SW version 1.2.5
remoteDeviceBckpFoLinkDown TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: Backup FO link down.
This trap is sent when a remote device's backup FO port fails.
Applicable for all ATARA devices.
Vars: trap severity, master slot number, channel number, port description"
::= 5207
-- this trap is applicable from SW version 1.2.5
remoteDeviceBckp2MainTpLink TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: Backup to Main TP link.
This trap is sent when a remote device's TP port in use switch from backup to main.
Applicable for all ATARA devices.
Vars: trap severity, master slot number, channel number, port description"
::= 5208
-- this trap is applicable from SW version 1.2.5
remoteDeviceMain2BckpTpLink TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMcm1xxChannelExtMvPortDescription }
DESCRIPTION
"Remote device: Main to Backup TP link.
This trap is sent when a remote device's TP port in use switch from main to backup.
Applicable for all ATARA devices.
Vars: trap severity, master slot number, channel number, port description"
::= 5209
-- E1/T1 related traps
-- this trap is applicable from SW version 1.3.0
localE1LosDetected TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsMcm100xE1PortIndex,
flMsMcm100xE1PortDescription }
DESCRIPTION
"Local E1/T1 LOS condition detected.
Applicable for E1/T1 local modules, i.e. MCM100-xE1/T1 and PCM110.
Vars: trap severity, slot number, E1/T1 port number, E1/T1 port description"
::= 5300
-- this trap is applicable from SW version 1.3.0
remoteE1LosDetected TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMsMcm100xE1PortIndex,
flMsMcm100xE1PortDescription }
DESCRIPTION
"Remote E1/T1 LOS condition detected.
Applicable for E1/T1 remote devices, i.e. LTA-xE1/T1.
Vars: trap severity, slot number, channel number, E1/T1 port number, E1/T1 port description"
::= 5301
-- this trap is applicable from SW version 1.3.0
localE1SignalDetected TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsMcm100xE1PortIndex,
flMsMcm100xE1PortDescription }
DESCRIPTION
"Local E1/T1 signal detected.
Applicable for E1/T1 local modules, i.e. MCM100-xE1/T1 and PCM110.
Vars: trap severity, slot number, E1/T1 port number, E1/T1 port description"
::= 5302
-- this trap is applicable from SW version 1.3.0
remoteE1SignalDetected TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMsMcm100xE1PortIndex,
flMsMcm100xE1PortDescription }
DESCRIPTION
"Remote E1/T1 signal detected.
Applicable for E1/T1 remote devices, i.e. LTA-xE1/T1.
Vars: trap severity, slot number, channel number, E1/T1 port number, E1/T1 port description"
::= 5303
-- this trap is applicable from SW version 1.3.0
localE1AisDetected TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsMcm100xE1PortIndex,
flMsMcm100xE1PortDescription }
DESCRIPTION
"Local E1/T1 AIS detected.
Applicable for E1/T1 local modules, i.e. MCM100-xE1/T1 and PCM110.
Vars: trap severity, slot number, E1/T1 port number, E1/T1 port description"
::= 5304
-- this trap is applicable from SW version 1.3.0
remoteE1AisDetected TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMsMcm100xE1PortIndex,
flMsMcm100xE1PortDescription }
DESCRIPTION
"Remote E1/T1 AIS detected.
Applicable for E1/T1 remote devices, i.e. LTA-xE1/T1.
Vars: trap severity, slot number, channel number, E1/T1 port number, E1/T1 port description"
::= 5305
-- this trap is applicable from SW version 1.3.0
localE1AisStopped TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsMcm100xE1PortIndex,
flMsMcm100xE1PortDescription }
DESCRIPTION
"Local E1/T1 AIS stream stopped.
Applicable for E1/T1 local modules, i.e. MCM100-xE1/T1 and PCM110.
Vars: trap severity, slot number, E1/T1 port number, E1/T1 port description"
::= 5306
-- this trap is applicable from SW version 1.3.0
remoteE1AisStopped TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flMsMcm100xE1PortIndex,
flMsMcm100xE1PortDescription }
DESCRIPTION
"Remote E1/T1 AIS stream stopped.
Applicable for E1/T1 remote devices, i.e. LTA-xE1/T1.
Vars: trap severity, slot number, channel number, E1/T1 port number, E1/T1 port description"
::= 5307
-- *******************************************************
-- Offline Configuration related traps
-- *******************************************************
-- this trap is applicable from SW version 1.4.0
offlineConfigConflictModule TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber }
DESCRIPTION
"Conflict detected: offline configuration and actual module dont match.
Vars: trap severity, slot number"
::= 5500
-- this trap is applicable from SW version 1.4.0
offlineConfigConflictRemote TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber }
DESCRIPTION
"Conflict detected: offline configuration and actual CPE dont match.
Vars: trap severity, slot number, channel number"
::= 5501
-- *******************************************************
-- SFP related traps
-- *******************************************************
-- this trap is applicable from SW version 1.6.0
localSfpPluggedIn TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local device: SFP plugged in.
Vars: trap severity, slot number, channel number, port number, port description"
::= 5600
-- this trap is applicable from SW version 1.6.0
localSfpUnplugged TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local device: SFP unplugged.
Vars: trap severity, slot number, channel number, port number, port description"
::= 5601
-- this trap is applicable from SW version 1.6.0
localSfpTxPowerLow TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local device: SFP Tx power low.
Vars: trap severity, slot number, channel number, port number, port description"
::= 5602
-- this trap is applicable from SW version 1.6.0
localSfpTxPowerNormal TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local device: SFP Tx power normal.
Vars: trap severity, slot number, channel number, port number, port description"
::= 5603
-- this trap is applicable from SW version 1.6.0
remoteSfpPluggedIn TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"remote device: SFP plugged in.
Vars: trap severity, slot number, channel number, port number, port description"
::= 5604
-- this trap is applicable from SW version 1.6.0
remoteSfpUnplugged TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"remote device: SFP unplugged.
Vars: trap severity, slot number, channel number, port number, port description"
::= 5605
-- this trap is applicable from SW version 1.6.0
remoteSfpTxPowerLow TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"remote device: SFP Tx power low.
Vars: trap severity, slot number, channel number, port number, port description"
::= 5606
-- this trap is applicable from SW version 1.6.0
remoteSfpTxPowerNormal TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"remote device: SFP Tx power normal.
Vars: trap severity, slot number, channel number, port number, port description"
::= 5607
-- *******************************************************
-- SFP related traps in redundancy devices
-- *******************************************************
-- this trap is applicable from SW version 1.6.2
localMainSfpPluggedIn TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local device: Main SFP plugged in.
Vars: trap severity, slot number, port number, port description"
::= 5650
-- this trap is applicable from SW version 1.6.2
localMainSfpUnplugged TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local device: Main SFP unplugged.
Vars: trap severity, slot number, port number, port description"
::= 5651
-- this trap is applicable from SW version 1.6.2
localMainSfpTxPowerLow TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local device: Main SFP Tx power low.
Vars: trap severity, slot number, port number, port description"
::= 5652
-- this trap is applicable from SW version 1.6.2
localMainSfpTxPowerNormal TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local device: Main SFP Tx power normal.
Vars: trap severity, slot number, port number, port description"
::= 5653
-- this trap is applicable from SW version 1.6.2
localBckpSfpPluggedIn TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local device: Backup SFP plugged in.
Vars: trap severity, slot number, port number, port description"
::= 5654
-- this trap is applicable from SW version 1.6.2
localBckpSfpUnplugged TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local device: Backup SFP unplugged.
Vars: trap severity, slot number, port number, port description"
::= 5655
-- this trap is applicable from SW version 1.6.2
localBckpSfpTxPowerLow TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local device: Backup SFP Tx power low.
Vars: trap severity, slot number, port number, port description"
::= 5656
-- this trap is applicable from SW version 1.6.2
localBckpSfpTxPowerNormal TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Local device: Backup SFP Tx power normal.
Vars: trap severity, slot number, port number, port description"
::= 5657
-- this trap is applicable from SW version 1.7.0
remoteMainSfpPluggedIn TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"remote device: Main SFP plugged in.
Vars: trap severity, slot number, channel number, port number, port description"
::= 5658
-- this trap is applicable from SW version 1.7.0
remoteMainSfpUnplugged TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"remote device: Main SFP unplugged.
Vars: trap severity, slot number, channel number, port number, port description"
::= 5659
-- this trap is applicable from SW version 1.7.0
remoteMainSfpTxPowerLow TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"remote device: Main SFP Tx power low.
Vars: trap severity, slot number, channel number, port number, port description"
::= 5660
-- this trap is applicable from SW version 1.7.0
remoteMainSfpTxPowerNormal TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"remote device: Main SFP Tx power normal.
Vars: trap severity, slot number, channel number, port number, port description"
::= 5661
-- this trap is applicable from SW version 1.7.0
remoteBckpSfpPluggedIn TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"remote device: Backup SFP plugged in.
Vars: trap severity, slot number, channel number, port number, port description"
::= 5662
-- this trap is applicable from SW version 1.7.0
remoteBckpSfpUnplugged TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"remote device: Backup SFP unplugged.
Vars: trap severity, slot number, channel number, port number, port description"
::= 5663
-- this trap is applicable from SW version 1.7.0
remoteBckpSfpTxPowerLow TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"remote device: Backup SFP Tx power low.
Vars: trap severity, slot number, channel number, port number, port description"
::= 5664
-- this trap is applicable from SW version 1.7.0
remoteMainSfpTxPowerNormal TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"remote device: Backup SFP Tx power normal.
Vars: trap severity, slot number, channel number, port number, port description"
::= 5665
-- this trap is applicable from SW version 1.7.0 / build 19
remoteDevUsingOldMaVersion TRAP-TYPE
ENTERPRISE fibrolanSNMP
VARIABLES { flTrapSeverity,
flMsChassisModuleNumber,
flMsChassisChannelNumber,
flSfpDevicePortIndex,
flMcm1000ChannelExtMvPortDescription }
DESCRIPTION
"Cannot manage remote device using old MA version.
Vars: trap severity, slot number, channel number, port number, port description"
::= 6000
END