mirror of
https://github.com/librenms/librenms.git
synced 2024-10-07 16:52:45 +00:00
* Extract DiscoveryItem and move some things to better places. Extract model class Fix up model construction. I have problem with construction... Makeshift model working. Switch constructor to factory. discover() and create() Support legacy discovery. Remove uneeded custom pollers Remove netonix custom detection as we try ucd on all os now. Add a few yaml procs. Fix a couple things. More processor discovery conversions Move Calix e7 to standard hrProcessorLoad, but it doesn't fully implement the HR-MIB, move things around to make it work. Add a few yaml procs. Fix a couple things. Correct some stupid mib stuff. Move more, drop php 5.3 Add netscaler which uses string indexes. Port fiberhome to yaml and use skip_values More conversions. BroadcomProcessorUsage Trait Serveriron and Ironware share some mibs. Create a common abstract os for them. Add yaml support for mib specification in each data entry Make legacy discover_processor() set 0 for hrDeviceIndex Untangle Dell switch OS processors Use use shared OS for groups if they don't have a specific group. fix silly mib mistake Make index optional Move HR and UCD to Traits and out of Processor. * forgot to update the fortiswitch index * Make sgos and avaya-ers match the old index. * fix comware test data * fix merge errors * fix dsm and remove pointless empty modules * file not found exception is in the wrong place. * Updated processor development docs
739 lines
27 KiB
Plaintext
739 lines
27 KiB
Plaintext
TUNNEL-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, transmission,
|
|
Integer32, IpAddress FROM SNMPv2-SMI -- [RFC2578]
|
|
|
|
RowStatus, StorageType FROM SNMPv2-TC -- [RFC2579]
|
|
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP FROM SNMPv2-CONF -- [RFC2580]
|
|
|
|
InetAddressType,
|
|
InetAddress FROM INET-ADDRESS-MIB -- [RFC4001]
|
|
|
|
IPv6FlowLabelOrAny FROM IPV6-FLOW-LABEL-MIB -- [RFC3595]
|
|
|
|
ifIndex,
|
|
InterfaceIndexOrZero FROM IF-MIB -- [RFC2863]
|
|
|
|
IANAtunnelType FROM IANAifType-MIB; -- [IFTYPE]
|
|
|
|
tunnelMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200505160000Z" -- May 16, 2005
|
|
ORGANIZATION "IETF IP Version 6 (IPv6) Working Group"
|
|
CONTACT-INFO
|
|
" Dave Thaler
|
|
Microsoft Corporation
|
|
One Microsoft Way
|
|
Redmond, WA 98052-6399
|
|
EMail: dthaler@microsoft.com"
|
|
DESCRIPTION
|
|
"The MIB module for management of IP Tunnels,
|
|
independent of the specific encapsulation scheme in
|
|
use.
|
|
|
|
Copyright (C) The Internet Society (2005). This
|
|
version of this MIB module is part of RFC 4087; see
|
|
the RFC itself for full legal notices."
|
|
|
|
REVISION "200505160000Z" -- May 16, 2005
|
|
DESCRIPTION
|
|
"IPv4-specific objects were deprecated, including
|
|
tunnelIfLocalAddress, tunnelIfRemoteAddress, the
|
|
tunnelConfigTable, and the tunnelMIBBasicGroup.
|
|
|
|
Added IP version-agnostic objects that should be used
|
|
instead, including tunnelIfAddressType,
|
|
tunnelIfLocalInetAddress, tunnelIfRemoteInetAddress,
|
|
the tunnelInetConfigTable, and the
|
|
tunnelIMIBInetGroup.
|
|
|
|
The new tunnelIfLocalInetAddress and
|
|
tunnelIfRemoteInetAddress objects are read-write,
|
|
rather than read-only.
|
|
|
|
Updated DESCRIPTION clauses of existing version-
|
|
agnostic objects (e.g., tunnelIfTOS) that contained
|
|
IPv4-specific text to cover IPv6 as well.
|
|
|
|
Added tunnelIfFlowLabel for tunnels over IPv6.
|
|
|
|
The encapsulation method was previously an INTEGER
|
|
type, and is now an IANA-maintained textual
|
|
convention.
|
|
|
|
Published as RFC 4087."
|
|
REVISION "199908241200Z" -- August 24, 1999
|
|
DESCRIPTION
|
|
"Initial version, published as RFC 2667."
|
|
::= { transmission 131 }
|
|
|
|
tunnelMIBObjects OBJECT IDENTIFIER ::= { tunnelMIB 1 }
|
|
|
|
tunnel OBJECT IDENTIFIER ::= { tunnelMIBObjects 1 }
|
|
|
|
-- the IP Tunnel MIB-Group
|
|
--
|
|
-- a collection of objects providing information about
|
|
-- IP Tunnels
|
|
|
|
tunnelIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TunnelIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The (conceptual) table containing information on
|
|
configured tunnels."
|
|
::= { tunnel 1 }
|
|
|
|
tunnelIfEntry OBJECT-TYPE
|
|
SYNTAX TunnelIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry (conceptual row) containing the information
|
|
on a particular configured tunnel."
|
|
INDEX { ifIndex }
|
|
::= { tunnelIfTable 1 }
|
|
|
|
TunnelIfEntry ::= SEQUENCE {
|
|
tunnelIfLocalAddress IpAddress, -- deprecated
|
|
tunnelIfRemoteAddress IpAddress, -- deprecated
|
|
tunnelIfEncapsMethod IANAtunnelType,
|
|
tunnelIfHopLimit Integer32,
|
|
tunnelIfSecurity INTEGER,
|
|
tunnelIfTOS Integer32,
|
|
tunnelIfFlowLabel IPv6FlowLabelOrAny,
|
|
tunnelIfAddressType InetAddressType,
|
|
tunnelIfLocalInetAddress InetAddress,
|
|
tunnelIfRemoteInetAddress InetAddress,
|
|
tunnelIfEncapsLimit Integer32
|
|
}
|
|
|
|
tunnelIfLocalAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The address of the local endpoint of the tunnel
|
|
(i.e., the source address used in the outer IP
|
|
header), or 0.0.0.0 if unknown or if the tunnel is
|
|
over IPv6.
|
|
|
|
Since this object does not support IPv6, it is
|
|
deprecated in favor of tunnelIfLocalInetAddress."
|
|
::= { tunnelIfEntry 1 }
|
|
|
|
tunnelIfRemoteAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The address of the remote endpoint of the tunnel
|
|
(i.e., the destination address used in the outer IP
|
|
header), or 0.0.0.0 if unknown, or an IPv6 address, or
|
|
|
|
the tunnel is not a point-to-point link (e.g., if it
|
|
is a 6to4 tunnel).
|
|
|
|
Since this object does not support IPv6, it is
|
|
deprecated in favor of tunnelIfRemoteInetAddress."
|
|
::= { tunnelIfEntry 2 }
|
|
|
|
tunnelIfEncapsMethod OBJECT-TYPE
|
|
SYNTAX IANAtunnelType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The encapsulation method used by the tunnel."
|
|
::= { tunnelIfEntry 3 }
|
|
|
|
tunnelIfHopLimit OBJECT-TYPE
|
|
SYNTAX Integer32 (0 | 1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPv4 TTL or IPv6 Hop Limit to use in the outer IP
|
|
header. A value of 0 indicates that the value is
|
|
copied from the payload's header."
|
|
::= { tunnelIfEntry 4 }
|
|
|
|
tunnelIfSecurity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1), -- no security
|
|
ipsec(2), -- IPsec security
|
|
other(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The method used by the tunnel to secure the outer IP
|
|
header. The value ipsec indicates that IPsec is used
|
|
between the tunnel endpoints for authentication or
|
|
encryption or both. More specific security-related
|
|
information may be available in a MIB module for the
|
|
security protocol in use."
|
|
::= { tunnelIfEntry 5 }
|
|
|
|
tunnelIfTOS OBJECT-TYPE
|
|
SYNTAX Integer32 (-2..63)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The method used to set the high 6 bits (the
|
|
|
|
differentiated services codepoint) of the IPv4 TOS or
|
|
IPv6 Traffic Class in the outer IP header. A value of
|
|
-1 indicates that the bits are copied from the
|
|
payload's header. A value of -2 indicates that a
|
|
traffic conditioner is invoked and more information
|
|
may be available in a traffic conditioner MIB module.
|
|
A value between 0 and 63 inclusive indicates that the
|
|
bit field is set to the indicated value.
|
|
|
|
Note: instead of the name tunnelIfTOS, a better name
|
|
would have been tunnelIfDSCPMethod, but the existing
|
|
name appeared in RFC 2667 and existing objects cannot
|
|
be renamed."
|
|
::= { tunnelIfEntry 6 }
|
|
|
|
tunnelIfFlowLabel OBJECT-TYPE
|
|
SYNTAX IPv6FlowLabelOrAny
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The method used to set the IPv6 Flow Label value.
|
|
This object need not be present in rows where
|
|
tunnelIfAddressType indicates the tunnel is not over
|
|
IPv6. A value of -1 indicates that a traffic
|
|
conditioner is invoked and more information may be
|
|
available in a traffic conditioner MIB. Any other
|
|
value indicates that the Flow Label field is set to
|
|
the indicated value."
|
|
::= { tunnelIfEntry 7 }
|
|
|
|
tunnelIfAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of address in the corresponding
|
|
tunnelIfLocalInetAddress and tunnelIfRemoteInetAddress
|
|
objects."
|
|
::= { tunnelIfEntry 8 }
|
|
|
|
tunnelIfLocalInetAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The address of the local endpoint of the tunnel
|
|
(i.e., the source address used in the outer IP
|
|
header). If the address is unknown, the value is
|
|
|
|
0.0.0.0 for IPv4 or :: for IPv6. The type of this
|
|
object is given by tunnelIfAddressType."
|
|
::= { tunnelIfEntry 9 }
|
|
|
|
tunnelIfRemoteInetAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The address of the remote endpoint of the tunnel
|
|
(i.e., the destination address used in the outer IP
|
|
header). If the address is unknown or the tunnel is
|
|
not a point-to-point link (e.g., if it is a 6to4
|
|
tunnel), the value is 0.0.0.0 for tunnels over IPv4 or
|
|
:: for tunnels over IPv6. The type of this object is
|
|
given by tunnelIfAddressType."
|
|
::= { tunnelIfEntry 10 }
|
|
|
|
tunnelIfEncapsLimit OBJECT-TYPE
|
|
SYNTAX Integer32 (-1 | 0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of additional encapsulations
|
|
permitted for packets undergoing encapsulation at this
|
|
node. A value of -1 indicates that no limit is
|
|
present (except as a result of the packet size)."
|
|
REFERENCE "RFC 2473, section 4.1.1"
|
|
::= { tunnelIfEntry 11 }
|
|
|
|
tunnelConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TunnelConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The (conceptual) table containing information on
|
|
configured tunnels. This table can be used to map a
|
|
set of tunnel endpoints to the associated ifIndex
|
|
value. It can also be used for row creation. Note
|
|
that every row in the tunnelIfTable with a fixed IPv4
|
|
destination address should have a corresponding row in
|
|
the tunnelConfigTable, regardless of whether it was
|
|
created via SNMP.
|
|
|
|
Since this table does not support IPv6, it is
|
|
deprecated in favor of tunnelInetConfigTable."
|
|
::= { tunnel 2 }
|
|
|
|
tunnelConfigEntry OBJECT-TYPE
|
|
SYNTAX TunnelConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"An entry (conceptual row) containing the information
|
|
on a particular configured tunnel.
|
|
|
|
Since this entry does not support IPv6, it is
|
|
deprecated in favor of tunnelInetConfigEntry."
|
|
INDEX { tunnelConfigLocalAddress,
|
|
tunnelConfigRemoteAddress,
|
|
tunnelConfigEncapsMethod,
|
|
tunnelConfigID }
|
|
::= { tunnelConfigTable 1 }
|
|
|
|
TunnelConfigEntry ::= SEQUENCE {
|
|
tunnelConfigLocalAddress IpAddress,
|
|
tunnelConfigRemoteAddress IpAddress,
|
|
tunnelConfigEncapsMethod IANAtunnelType,
|
|
tunnelConfigID Integer32,
|
|
tunnelConfigIfIndex InterfaceIndexOrZero,
|
|
tunnelConfigStatus RowStatus
|
|
}
|
|
|
|
tunnelConfigLocalAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The address of the local endpoint of the tunnel, or
|
|
0.0.0.0 if the device is free to choose any of its
|
|
addresses at tunnel establishment time.
|
|
|
|
Since this object does not support IPv6, it is
|
|
deprecated in favor of tunnelInetConfigLocalAddress."
|
|
::= { tunnelConfigEntry 1 }
|
|
|
|
tunnelConfigRemoteAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The address of the remote endpoint of the tunnel.
|
|
|
|
Since this object does not support IPv6, it is
|
|
deprecated in favor of tunnelInetConfigRemoteAddress."
|
|
::= { tunnelConfigEntry 2 }
|
|
|
|
tunnelConfigEncapsMethod OBJECT-TYPE
|
|
SYNTAX IANAtunnelType
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The encapsulation method used by the tunnel.
|
|
|
|
Since this object does not support IPv6, it is
|
|
deprecated in favor of tunnelInetConfigEncapsMethod."
|
|
::= { tunnelConfigEntry 3 }
|
|
|
|
tunnelConfigID OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"An identifier used to distinguish between multiple
|
|
tunnels of the same encapsulation method, with the
|
|
same endpoints. If the encapsulation protocol only
|
|
allows one tunnel per set of endpoint addresses (such
|
|
as for GRE or IP-in-IP), the value of this object is
|
|
1. For encapsulation methods (such as L2F) which
|
|
allow multiple parallel tunnels, the manager is
|
|
responsible for choosing any ID which does not
|
|
conflict with an existing row, such as choosing a
|
|
random number.
|
|
|
|
Since this object does not support IPv6, it is
|
|
deprecated in favor of tunnelInetConfigID."
|
|
::= { tunnelConfigEntry 4 }
|
|
|
|
tunnelConfigIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"If the value of tunnelConfigStatus for this row is
|
|
active, then this object contains the value of ifIndex
|
|
corresponding to the tunnel interface. A value of 0
|
|
is not legal in the active state, and means that the
|
|
interface index has not yet been assigned.
|
|
|
|
Since this object does not support IPv6, it is
|
|
deprecated in favor of tunnelInetConfigIfIndex."
|
|
::= { tunnelConfigEntry 5 }
|
|
|
|
tunnelConfigStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The status of this row, by which new entries may be
|
|
created, or old entries deleted from this table. The
|
|
agent need not support setting this object to
|
|
createAndWait or notInService since there are no other
|
|
writable objects in this table, and writable objects
|
|
in rows of corresponding tables such as the
|
|
tunnelIfTable may be modified while this row is
|
|
active.
|
|
|
|
To create a row in this table for an encapsulation
|
|
method which does not support multiple parallel
|
|
tunnels with the same endpoints, the management
|
|
station should simply use a tunnelConfigID of 1, and
|
|
set tunnelConfigStatus to createAndGo. For
|
|
encapsulation methods such as L2F which allow multiple
|
|
parallel tunnels, the management station may select a
|
|
pseudo-random number to use as the tunnelConfigID and
|
|
set tunnelConfigStatus to createAndGo. In the event
|
|
that this ID is already in use and an
|
|
inconsistentValue is returned in response to the set
|
|
operation, the management station should simply select
|
|
a new pseudo-random number and retry the operation.
|
|
|
|
Creating a row in this table will cause an interface
|
|
index to be assigned by the agent in an
|
|
implementation-dependent manner, and corresponding
|
|
rows will be instantiated in the ifTable and the
|
|
tunnelIfTable. The status of this row will become
|
|
active as soon as the agent assigns the interface
|
|
index, regardless of whether the interface is
|
|
operationally up.
|
|
|
|
Deleting a row in this table will likewise delete the
|
|
corresponding row in the ifTable and in the
|
|
tunnelIfTable.
|
|
|
|
Since this object does not support IPv6, it is
|
|
deprecated in favor of tunnelInetConfigStatus."
|
|
::= { tunnelConfigEntry 6 }
|
|
|
|
tunnelInetConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TunnelInetConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The (conceptual) table containing information on
|
|
configured tunnels. This table can be used to map a
|
|
set of tunnel endpoints to the associated ifIndex
|
|
value. It can also be used for row creation. Note
|
|
that every row in the tunnelIfTable with a fixed
|
|
destination address should have a corresponding row in
|
|
the tunnelInetConfigTable, regardless of whether it
|
|
was created via SNMP."
|
|
::= { tunnel 3 }
|
|
|
|
tunnelInetConfigEntry OBJECT-TYPE
|
|
SYNTAX TunnelInetConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry (conceptual row) containing the information
|
|
on a particular configured tunnel. Note that there is
|
|
a 128 subid maximum for object OIDs. Implementers
|
|
need to be aware that if the total number of octets in
|
|
tunnelInetConfigLocalAddress and
|
|
tunnelInetConfigRemoteAddress exceeds 110 then OIDs of
|
|
column instances in this table will have more than 128
|
|
sub-identifiers and cannot be accessed using SNMPv1,
|
|
SNMPv2c, or SNMPv3. In practice this is not expected
|
|
to be a problem since IPv4 and IPv6 addresses will not
|
|
cause the limit to be reached, but if other types are
|
|
supported by an agent, care must be taken to ensure
|
|
that the sum of the lengths do not cause the limit to
|
|
be exceeded."
|
|
INDEX { tunnelInetConfigAddressType,
|
|
tunnelInetConfigLocalAddress,
|
|
tunnelInetConfigRemoteAddress,
|
|
tunnelInetConfigEncapsMethod,
|
|
tunnelInetConfigID }
|
|
::= { tunnelInetConfigTable 1 }
|
|
|
|
TunnelInetConfigEntry ::= SEQUENCE {
|
|
tunnelInetConfigAddressType InetAddressType,
|
|
tunnelInetConfigLocalAddress InetAddress,
|
|
tunnelInetConfigRemoteAddress InetAddress,
|
|
tunnelInetConfigEncapsMethod IANAtunnelType,
|
|
tunnelInetConfigID Integer32,
|
|
tunnelInetConfigIfIndex InterfaceIndexOrZero,
|
|
tunnelInetConfigStatus RowStatus,
|
|
tunnelInetConfigStorageType StorageType
|
|
}
|
|
|
|
tunnelInetConfigAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The address type over which the tunnel encapsulates
|
|
packets."
|
|
::= { tunnelInetConfigEntry 1 }
|
|
|
|
tunnelInetConfigLocalAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The address of the local endpoint of the tunnel, or
|
|
0.0.0.0 (for IPv4) or :: (for IPv6) if the device is
|
|
free to choose any of its addresses at tunnel
|
|
establishment time."
|
|
::= { tunnelInetConfigEntry 2 }
|
|
|
|
tunnelInetConfigRemoteAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The address of the remote endpoint of the tunnel."
|
|
::= { tunnelInetConfigEntry 3 }
|
|
|
|
tunnelInetConfigEncapsMethod OBJECT-TYPE
|
|
SYNTAX IANAtunnelType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The encapsulation method used by the tunnel."
|
|
::= { tunnelInetConfigEntry 4 }
|
|
|
|
tunnelInetConfigID OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An identifier used to distinguish between multiple
|
|
tunnels of the same encapsulation method, with the
|
|
same endpoints. If the encapsulation protocol only
|
|
allows one tunnel per set of endpoint addresses (such
|
|
as for GRE or IP-in-IP), the value of this object is
|
|
1. For encapsulation methods (such as L2F) which
|
|
allow multiple parallel tunnels, the manager is
|
|
responsible for choosing any ID which does not
|
|
|
|
conflict with an existing row, such as choosing a
|
|
random number."
|
|
::= { tunnelInetConfigEntry 5 }
|
|
|
|
tunnelInetConfigIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the value of tunnelInetConfigStatus for this row
|
|
is active, then this object contains the value of
|
|
ifIndex corresponding to the tunnel interface. A
|
|
value of 0 is not legal in the active state, and means
|
|
that the interface index has not yet been assigned."
|
|
::= { tunnelInetConfigEntry 6 }
|
|
|
|
tunnelInetConfigStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this row, by which new entries may be
|
|
created, or old entries deleted from this table. The
|
|
agent need not support setting this object to
|
|
createAndWait or notInService since there are no other
|
|
writable objects in this table, and writable objects
|
|
in rows of corresponding tables such as the
|
|
tunnelIfTable may be modified while this row is
|
|
active.
|
|
|
|
To create a row in this table for an encapsulation
|
|
method which does not support multiple parallel
|
|
tunnels with the same endpoints, the management
|
|
station should simply use a tunnelInetConfigID of 1,
|
|
and set tunnelInetConfigStatus to createAndGo. For
|
|
encapsulation methods such as L2F which allow multiple
|
|
parallel tunnels, the management station may select a
|
|
pseudo-random number to use as the tunnelInetConfigID
|
|
and set tunnelInetConfigStatus to createAndGo. In the
|
|
event that this ID is already in use and an
|
|
inconsistentValue is returned in response to the set
|
|
operation, the management station should simply select
|
|
a new pseudo-random number and retry the operation.
|
|
|
|
Creating a row in this table will cause an interface
|
|
index to be assigned by the agent in an
|
|
implementation-dependent manner, and corresponding
|
|
rows will be instantiated in the ifTable and the
|
|
|
|
tunnelIfTable. The status of this row will become
|
|
active as soon as the agent assigns the interface
|
|
index, regardless of whether the interface is
|
|
operationally up.
|
|
|
|
Deleting a row in this table will likewise delete the
|
|
corresponding row in the ifTable and in the
|
|
tunnelIfTable."
|
|
::= { tunnelInetConfigEntry 7 }
|
|
|
|
tunnelInetConfigStorageType OBJECT-TYPE
|
|
SYNTAX StorageType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The storage type of this row. If the row is
|
|
permanent(4), no objects in the row need be writable."
|
|
::= { tunnelInetConfigEntry 8 }
|
|
|
|
-- conformance information
|
|
|
|
tunnelMIBConformance
|
|
OBJECT IDENTIFIER ::= { tunnelMIB 2 }
|
|
tunnelMIBCompliances
|
|
OBJECT IDENTIFIER ::= { tunnelMIBConformance 1 }
|
|
tunnelMIBGroups OBJECT IDENTIFIER ::= { tunnelMIBConformance 2 }
|
|
|
|
-- compliance statements
|
|
|
|
tunnelMIBCompliance MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The (deprecated) IPv4-only compliance statement for
|
|
the IP Tunnel MIB.
|
|
|
|
This is deprecated in favor of
|
|
tunnelMIBInetFullCompliance and
|
|
tunnelMIBInetReadOnlyCompliance."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { tunnelMIBBasicGroup }
|
|
|
|
OBJECT tunnelIfHopLimit
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT tunnelIfTOS
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT tunnelConfigStatus
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
::= { tunnelMIBCompliances 1 }
|
|
|
|
tunnelMIBInetFullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The full compliance statement for the IP Tunnel MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { tunnelMIBInetGroup }
|
|
|
|
OBJECT tunnelIfAddressType
|
|
SYNTAX InetAddressType { ipv4(1), ipv6(2),
|
|
ipv4z(3), ipv6z(4) }
|
|
DESCRIPTION
|
|
"An implementation is only required to support IPv4
|
|
and/or IPv6 addresses. An implementation only needs to
|
|
support the addresses it actually supports on the
|
|
device."
|
|
::= { tunnelMIBCompliances 2 }
|
|
|
|
tunnelMIBInetReadOnlyCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The read-only compliance statement for the IP Tunnel
|
|
MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { tunnelMIBInetGroup }
|
|
|
|
OBJECT tunnelIfHopLimit
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT tunnelIfTOS
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT tunnelIfFlowLabel
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT tunnelIfAddressType
|
|
SYNTAX InetAddressType { ipv4(1), ipv6(2),
|
|
ipv4z(3), ipv6z(4) }
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required.
|
|
|
|
An implementation is only required to support IPv4
|
|
and/or IPv6 addresses. An implementation only needs to
|
|
support the addresses it actually supports on the
|
|
device."
|
|
|
|
OBJECT tunnelIfLocalInetAddress
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT tunnelIfRemoteInetAddress
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT tunnelIfEncapsLimit
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
|
|
OBJECT tunnelInetConfigStatus
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required, and active is the only
|
|
status that needs to be supported."
|
|
|
|
OBJECT tunnelInetConfigStorageType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Write access is not required."
|
|
::= { tunnelMIBCompliances 3 }
|
|
|
|
-- units of conformance
|
|
|
|
tunnelMIBBasicGroup OBJECT-GROUP
|
|
OBJECTS { tunnelIfLocalAddress, tunnelIfRemoteAddress,
|
|
tunnelIfEncapsMethod, tunnelIfHopLimit, tunnelIfTOS,
|
|
tunnelIfSecurity, tunnelConfigIfIndex, tunnelConfigStatus }
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A collection of objects to support basic management
|
|
|
|
of IPv4 Tunnels. Since this group cannot support
|
|
IPv6, it is deprecated in favor of
|
|
tunnelMIBInetGroup."
|
|
::= { tunnelMIBGroups 1 }
|
|
|
|
tunnelMIBInetGroup OBJECT-GROUP
|
|
OBJECTS { tunnelIfAddressType, tunnelIfLocalInetAddress,
|
|
tunnelIfRemoteInetAddress, tunnelIfEncapsMethod,
|
|
tunnelIfEncapsLimit,
|
|
tunnelIfHopLimit, tunnelIfTOS, tunnelIfFlowLabel,
|
|
tunnelIfSecurity, tunnelInetConfigIfIndex,
|
|
tunnelInetConfigStatus, tunnelInetConfigStorageType }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects to support basic management
|
|
of IPv4 and IPv6 Tunnels."
|
|
::= { tunnelMIBGroups 2 }
|
|
|
|
END
|