<?php
/**
* ApcPduOutletTest.php
*
* -Description-
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <https://www.gnu.org/licenses/>.
*
* @link https://www.librenms.org
*/
namespace LibreNMS\Tests\Feature\SnmpTraps;
use LibreNMS\Enum\Severity;
class ApcPduOutletTest extends SnmpTrapTestCase
{
public function testOutletOff(): void
{
$this->assertTrapLogsMessage(<<<'TRAP'
{{ hostname }}
UDP: [{{ ip }}]:161->[192.168.5.5]:162
DISMAN-EVENT-MIB::sysUpTimeInstance 84:21:45:07.07
SNMPv2-MIB::snmpTrapOID.0 PowerNet-MIB::outletOff
PowerNet-MIB::mtrapargsInteger.0 2
PowerNet-MIB::mtrapargsString.0 \"An outlet has turned on. If the outlet number is 0, then all outlets have turned on.\"
SNMPv2-MIB::snmpTrapEnterprise.0 PowerNet-MIB::apc
TRAP,
'APC PDU: Outlet has turned off: 2',
'Could not handle outletOff trap',
[Severity::Warning],
);
}
public function testOutletOn(): void
{
$this->assertTrapLogsMessage(<<<'TRAP'
{{ hostname }}
UDP: [{{ ip }}]:161->[192.168.5.5]:162
DISMAN-EVENT-MIB::sysUpTimeInstance 84:21:45:07.07
SNMPv2-MIB::snmpTrapOID.0 PowerNet-MIB::outletOn
PowerNet-MIB::mtrapargsInteger.0 2
PowerNet-MIB::mtrapargsString.0 \"An outlet has turned on. If the outlet number is 0, then all outlets have turned on.\"
SNMPv2-MIB::snmpTrapEnterprise.0 PowerNet-MIB::apc
TRAP,
'APC PDU: Outlet has been turned on: 2',
'Could not handle outletOn trap',
[Severity::Warning],
);
}
public function testOutletReboot(): void
{
$this->assertTrapLogsMessage(<<<'TRAP'
{{ hostname }}
UDP: [{{ ip }}]:161->[192.168.5.5]:162
DISMAN-EVENT-MIB::sysUpTimeInstance 84:21:45:07.07
SNMPv2-MIB::snmpTrapOID.0 PowerNet-MIB::outletReboot
PowerNet-MIB::mtrapargsInteger.0 2
PowerNet-MIB::mtrapargsString.0 \"An outlet has rebooted. If the outlet number is 0, then all outlets have rebooted.\"
SNMPv2-MIB::snmpTrapEnterprise.0 PowerNet-MIB::apc
TRAP,
'APC PDU: Outlet has rebooted: 2',
'Could not handle outletReboot trap',
[Severity::Warning],
);
}
}