| RADLAN-rndApplications DEFINITIONS ::= BEGIN
 | |
| 
 | |
| -- Title:      RADLAN Application Private Extension
 | |
| -- Version:    7.37.00.00
 | |
| -- Date:       17 May 2004
 | |
| 
 | |
| IMPORTS
 | |
|     rnd                                                     FROM RADLAN-MIB
 | |
|     InterfaceIndexOrZero, InterfaceIndex, ifIndex           FROM IF-MIB
 | |
|     DisplayString                                           FROM SNMPv2-TC-v1
 | |
|     Unsigned32, Counter32, IpAddress,
 | |
|     MODULE-IDENTITY, OBJECT-TYPE                            FROM SNMPv2-SMI
 | |
|     RowStatus, TruthValue,
 | |
|     TEXTUAL-CONVENTION                                      FROM SNMPv2-TC;
 | |
| 
 | |
| rndApplications  MODULE-IDENTITY
 | |
|                  LAST-UPDATED "200406010000Z"
 | |
|                  ORGANIZATION "Radlan Computer Communications Ltd."
 | |
|                  CONTACT-INFO
 | |
|                       "radlan.com"
 | |
|                  DESCRIPTION
 | |
|                       "The private MIB module definition for RND applications MIB."
 | |
|                  REVISION "200406010000Z"
 | |
|                  DESCRIPTION
 | |
|                       "Initial version of this MIB."
 | |
|                  ::= { rnd 35 }
 | |
| 
 | |
| 
 | |
| -- Obsolete
 | |
| -- rsServerDispatcher  OBJECT IDENTIFIER ::= { rndApplications 1}
 | |
| 
 | |
| -- rndMidLevelManagement group contains variables which direct the mid-level
 | |
| -- management stations how to monitor and manage their domains.
 | |
| 
 | |
| rndMidLevelManagement  OBJECT IDENTIFIER ::= { rndApplications 2} -- NEW Group
 | |
| 
 | |
| rndAlarmOptions  OBJECT IDENTIFIER ::= { rndMidLevelManagement 2}
 | |
| 
 | |
| rndAlarmEnabling OBJECT-TYPE
 | |
|     SYNTAX INTEGER {
 | |
|         enabled(1),
 | |
|         disabled(2)
 | |
|         }
 | |
|     MAX-ACCESS  read-write
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "Indicates whether alarms should be issued to the high-level
 | |
|          NMS "
 | |
|      ::=  { rndAlarmOptions 1 }
 | |
| 
 | |
| rndAlarmInterval OBJECT-TYPE
 | |
|     SYNTAX INTEGER
 | |
|     MAX-ACCESS  read-write
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "Indicates the minimal period of time which must pass after issuing
 | |
|          an alarm before issuing the same alarm again."
 | |
|      ::=  { rndAlarmOptions 2 }
 | |
| 
 | |
| rndMonitoredElementsTable  OBJECT-TYPE
 | |
|    SYNTAX SEQUENCE OF RndMonitoredElementEntry
 | |
|    MAX-ACCESS   not-accessible
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The table of monitored elements of the network"
 | |
|     ::= {rndMidLevelManagement 3}
 | |
| 
 | |
| rndMonitoredElementEntry  OBJECT-TYPE
 | |
|    SYNTAX RndMonitoredElementEntry
 | |
|    MAX-ACCESS   not-accessible
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|        " The row definition for this table."
 | |
|    INDEX { rndMonitoredElementAddress }
 | |
|     ::= {rndMonitoredElementsTable 1}
 | |
| 
 | |
| RndMonitoredElementEntry ::= SEQUENCE {
 | |
| 
 | |
| rndMonitoredElementAddress    IpAddress,
 | |
| rndMonitoredElementCommunity  DisplayString(SIZE(1..20)),
 | |
| rndMonitoredElementLabel      DisplayString(SIZE(1..20)),
 | |
| rndDefaultPollingInterval     INTEGER,
 | |
| rndDefaultLogFile             DisplayString,
 | |
| rndMonitoredElementStatus     RowStatus
 | |
| }
 | |
| rndMonitoredElementAddress OBJECT-TYPE
 | |
|    SYNTAX IpAddress
 | |
|    MAX-ACCESS   read-only
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The IP address of the monitored element"
 | |
|      ::=  {rndMonitoredElementEntry  1 }
 | |
| 
 | |
| rndMonitoredElementCommunity OBJECT-TYPE
 | |
|    SYNTAX DisplayString(SIZE(1..20))
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The community of the monitored element"
 | |
|      ::=  {rndMonitoredElementEntry 2  }
 | |
| 
 | |
| rndMonitoredElementLabel OBJECT-TYPE
 | |
|    SYNTAX DisplayString(SIZE(1..20))
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The label assigned by the network manager to the monitored element"
 | |
|      ::=  {rndMonitoredElementEntry 3}
 | |
| 
 | |
| rndDefaultPollingInterval OBJECT-TYPE
 | |
|    SYNTAX INTEGER
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The default period of time between two consecutive pollings of the
 | |
|      monitored element for the value of an object instance. If no other polling
 | |
|      interval is specifically assigned to the monitored object instance, this
 | |
|      one will be used"
 | |
|      ::=  {rndMonitoredElementEntry 4}
 | |
| 
 | |
| rndDefaultLogFile OBJECT-TYPE
 | |
|    SYNTAX DisplayString
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The default file path of the log-file which will contain the polling
 | |
|      results for the monitored element. If no other file path is specifically
 | |
|      assigned to the monitored object instance, this log-file will be used."
 | |
| 
 | |
|      ::=  {rndMonitoredElementEntry  5}
 | |
| 
 | |
| rndMonitoredElementStatus OBJECT-TYPE
 | |
|    SYNTAX RowStatus
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|          "It is used to manage the monitored elements table and indicates
 | |
|           the current monitoring status of an element."
 | |
|      ::=  {rndMonitoredElementEntry  6}
 | |
| 
 | |
| rndMonitoringTable  OBJECT-TYPE
 | |
|    SYNTAX SEQUENCE OF RndMonitoringEntry
 | |
|    MAX-ACCESS   not-accessible
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The table of monitored object instances. Each monitored object instance
 | |
|      belongs to a monitored element previously entered in the
 | |
|      rndMonitoredElementsTable. "
 | |
|     ::= {rndMidLevelManagement 4}
 | |
| 
 | |
| rndMonitoringEntry OBJECT-TYPE
 | |
|    SYNTAX RndMonitoringEntry
 | |
|    MAX-ACCESS   not-accessible
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|        " The row definition for this table."
 | |
|    INDEX { rndMonitoredElement, IMPLIED rndMonitoredObjectInstanceLabel }
 | |
|     ::= {rndMonitoringTable 1}
 | |
| 
 | |
| RndMonitoringEntry ::= SEQUENCE {
 | |
| 
 | |
| rndMonitoredElement             DisplayString(SIZE(1..20)),
 | |
| rndMonitoredObjectInstanceLabel DisplayString,
 | |
| rndMonitoredObjectName          DisplayString,
 | |
| rndMonitoredObjectIdentifier    OBJECT IDENTIFIER,
 | |
| rndMonitoredObjectInstance      OBJECT IDENTIFIER,
 | |
| rndMonitoredObjectSyntax        INTEGER,
 | |
| rndMonitoringInterval           INTEGER,
 | |
| rndAlarmMaxTreshold             INTEGER,
 | |
| rndAlarmMinTreshold             INTEGER,
 | |
| rndMonitoringLogfile            DisplayString,
 | |
| rndMonitoringEntryStatus        RowStatus,
 | |
| rndMonitoredIntegerInstance     INTEGER
 | |
| }
 | |
| 
 | |
| rndMonitoredElement OBJECT-TYPE
 | |
|    SYNTAX DisplayString(SIZE(1..20))
 | |
|    MAX-ACCESS   read-only
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "A label assigned by the network manager to a monitored element to
 | |
|      which this monitored object instance belongs. This label must have
 | |
|      been previously entered in an instance of rndMonitoredElementLabel"
 | |
|     ::=  {rndMonitoringEntry  1}
 | |
| 
 | |
| rndMonitoredObjectInstanceLabel OBJECT-TYPE
 | |
|    SYNTAX DisplayString(SIZE(1..20))
 | |
|    MAX-ACCESS   read-only
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The label assigned by the network manager to the monitored object instance"
 | |
|     ::=  {rndMonitoringEntry  2}
 | |
| 
 | |
| rndMonitoredObjectName OBJECT-TYPE
 | |
|    SYNTAX DisplayString(SIZE(0..20))
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The symbolic object type name of the object to which the monitored object
 | |
|      instance belongs (as it appears the MIB module definition). In case of
 | |
|      ambiguity the <MIB module name> : <object type name> format should be used.
 | |
|      An instance of rndMonitoredObjectName need not be assigned any value, if
 | |
|      the corresponding instance of rndMonitoredObjectIdentifier is assigned a
 | |
|      value, since any one of these, together with the object instance
 | |
|      identifier, suffices to unambigously identify the monitored object
 | |
|      instance."
 | |
| 
 | |
|     ::=  {rndMonitoringEntry  3}
 | |
| 
 | |
| rndMonitoredObjectIdentifier OBJECT-TYPE
 | |
|    SYNTAX OBJECT IDENTIFIER
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The object identifier of the object to which the monitored object
 | |
|      instance belongs.
 | |
|      An instance of rndMonitoredObjectIdentifier need not be assigned any value, if
 | |
|      the corresponding instance of rndMonitoredObjectName is assigned a value,
 | |
|      since any one of these, together with the object instance identifier,
 | |
|      suffices to unambigously identify the monitored object instance."
 | |
| 
 | |
|     ::=  {rndMonitoringEntry  4}
 | |
| 
 | |
| rndMonitoredObjectInstance OBJECT-TYPE
 | |
|    SYNTAX OBJECT IDENTIFIER
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|         "The instance identifier (key) of the monitored object instance."
 | |
|     ::=  {rndMonitoringEntry  5}
 | |
| 
 | |
| rndMonitoredObjectSyntax OBJECT-TYPE
 | |
|    SYNTAX INTEGER {
 | |
|        integer(1),
 | |
|        octet-string(2),
 | |
|        ip-address(3),
 | |
|        object-identifier(4)
 | |
|      }
 | |
| 
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The syntax of the monitored object instance (i.e., the syntax of the object
 | |
|      type of the object to which the monitored instance belongs).
 | |
|      Need not be assigned any value if the corresponding instance of
 | |
|      rndMonitoredObjectName has been assigned a value"
 | |
|     ::=  {rndMonitoringEntry  6}
 | |
| 
 | |
| rndMonitoringInterval OBJECT-TYPE
 | |
|    SYNTAX INTEGER
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The period of time between two consecutive retrievals of the monitored
 | |
|      object instance's value."
 | |
|     ::=  {rndMonitoringEntry  7}
 | |
| 
 | |
| 
 | |
| rndAlarmMaxTreshold OBJECT-TYPE
 | |
|    SYNTAX INTEGER
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The value of the monitored object instance, the exceeding of which
 | |
|      will cause the generation of an alarm to the high-level management
 | |
|      station."
 | |
|     ::=  {rndMonitoringEntry 8}
 | |
| 
 | |
| rndAlarmMinTreshold OBJECT-TYPE
 | |
|    SYNTAX INTEGER
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "If the value of the monitored object instance falls below the value
 | |
|      assigned to rndAlarmMinTreshold, an alarm to the high-level management
 | |
|      station will be issued."
 | |
|     ::=  {rndMonitoringEntry  9}
 | |
| 
 | |
| 
 | |
| rndMonitoringLogfile OBJECT-TYPE
 | |
|    SYNTAX DisplayString
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The entire path of the file in which the results of the monitoring
 | |
|      of this object instance should be recorded."
 | |
|     ::=  {rndMonitoringEntry  10}
 | |
| 
 | |
| rndMonitoringEntryStatus OBJECT-TYPE
 | |
|    SYNTAX RowStatus
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|          "It is used to manage the monitored object instances table and
 | |
|           indicates the current monitoring status of an object instance."
 | |
|     ::=  {rndMonitoringEntry  11}
 | |
| 
 | |
| rndMonitoredIntegerInstance OBJECT-TYPE
 | |
|    SYNTAX INTEGER
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|          ""
 | |
|     ::=  {rndMonitoringEntry  12}
 | |
| 
 | |
| rndMibFilesTable  OBJECT-TYPE
 | |
|    SYNTAX SEQUENCE OF RndMibFileEntry
 | |
|    MAX-ACCESS   not-accessible
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The table of monitored object instances. Each monitored object instance
 | |
|      belongs to a monitored element previously entered in the
 | |
|      rndMonitoredElementsTable. "
 | |
|     ::= {rndMidLevelManagement 5}
 | |
| 
 | |
| rndMibFileEntry OBJECT-TYPE
 | |
|    SYNTAX RndMibFileEntry
 | |
|    MAX-ACCESS   not-accessible
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|        " The row definition for this table."
 | |
|    INDEX { rndMibFileIndex }
 | |
|     ::= {rndMibFilesTable 1}
 | |
| 
 | |
| RndMibFileEntry ::= SEQUENCE {
 | |
| 
 | |
| rndMibFileIndex                 INTEGER,
 | |
| rndMibFilePath                  DisplayString,
 | |
| rndMibFileRefresh               INTEGER,
 | |
| rndMibFileEntryStatus           RowStatus
 | |
| }
 | |
| rndMibFileIndex OBJECT-TYPE
 | |
|    SYNTAX INTEGER
 | |
|    MAX-ACCESS   read-only
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The number of the MIB file in the list MIB files supported by the
 | |
|      Mid-Level management station. The order of the MIB files in this
 | |
|      list must reflect the the IMPORT relation between the MIBS contained
 | |
|      in the MIB files, i.e., if MIB A IMPORTS FROM MIB B, the file containing
 | |
|      MIB A must have a lesser index in this table than the file containing
 | |
|      MIB B."
 | |
|     ::=  {rndMibFileEntry  1}
 | |
| 
 | |
| 
 | |
| rndMibFilePath OBJECT-TYPE
 | |
|    SYNTAX DisplayString
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The path of the MIB file in the MIB file server."
 | |
|     ::=  {rndMibFileEntry  2}
 | |
| 
 | |
| rndMibFileRefresh OBJECT-TYPE
 | |
|    SYNTAX INTEGER {
 | |
|       no(1),
 | |
|       yes(2)
 | |
|    }
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "Indicates if the file should be fetched after setting this entry from the
 | |
|      MIB file server."
 | |
|     ::=  {rndMibFileEntry  3}
 | |
| 
 | |
| rndMibFileEntryStatus OBJECT-TYPE
 | |
|    SYNTAX RowStatus
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|          "It is used to manage the MIB files table."
 | |
|     ::=  {rndMibFileEntry  4}
 | |
| 
 | |
| rndHardwareConfiguration OBJECT-TYPE
 | |
|     SYNTAX TruthValue
 | |
|     MAX-ACCESS  read-write
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "Indicates whether the current SET SNMP PDU contains hardware
 | |
|          configuration (i.e., normally read-only variables). SET of such
 | |
|          variables in the Mid-level management station will be allowed only
 | |
|          if this variable is included in the SNMP PDU and its value is true.
 | |
|          Its value as returned in  a GET SNMP PDU will always be false."
 | |
|     ::= {rndMidLevelManagement 6}
 | |
| 
 | |
| rndEraseSimulatedConfiguration OBJECT-TYPE
 | |
|     SYNTAX INTEGER {
 | |
|         eraseSimulatedConfiguration(1),
 | |
|         simulatedConfigurationPresent(2),
 | |
|         simulatedConfigurationErased(3)
 | |
|         }
 | |
|     MAX-ACCESS  read-write
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "eraseSimulatedConfiguration instructs the MLNMS to erase all the
 | |
|          simulated configuration from its configuration data-base (CDB). This
 | |
|          the only accepted value for SNMP SET statements and will never be
 | |
|          returned in SNMP GET statements.
 | |
|          simulatedConfigurationPresent indicates that the MLNMS currently has
 | |
|          a simulated configuration.
 | |
|          simulatedConfigurationErased indicates that the MLNMS currently has
 | |
|          no simulated configuration."
 | |
|     ::= {rndMidLevelManagement 7}
 | |
| 
 | |
| rndDeleteValuesTable  OBJECT-TYPE
 | |
|    SYNTAX SEQUENCE OF RndDeleteValuesEntry
 | |
|    MAX-ACCESS   not-accessible
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "This table indicates which MIB variables are row status fields which
 | |
|      control the status of the entry to which they belong. This table also
 | |
|      indicates which (integer!) value of these MIB variables will cause, if
 | |
|      present in a SNMP SET PDU, the deletion of the conceptual row instance
 | |
|      to which the SET MIB variable instance belongs."
 | |
|     ::= {rndMidLevelManagement 8}
 | |
| 
 | |
| rndDeleteValuesEntry  OBJECT-TYPE
 | |
|    SYNTAX RndDeleteValuesEntry
 | |
|    MAX-ACCESS   not-accessible
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|        " The row definition for the rndDeleteValuesTable table."
 | |
|    INDEX { IMPLIED rndRowStatusVariableName }
 | |
|     ::= {rndDeleteValuesTable 1}
 | |
| 
 | |
| RndDeleteValuesEntry ::= SEQUENCE {
 | |
| 
 | |
| rndRowStatusVariableName    DisplayString,
 | |
| rndRowStatusObjectId        OBJECT IDENTIFIER,
 | |
| rndRowDeleteValue           INTEGER,
 | |
| rndDeleteValueEntryStatus   RowStatus
 | |
| }
 | |
| 
 | |
| rndRowStatusVariableName OBJECT-TYPE
 | |
|    SYNTAX DisplayString(SIZE(1..80))
 | |
| --   MAX-ACCESS         read-only
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The name of the row status field. This name may not necessarily be any
 | |
|      name which is present in the MIBs loaded into the MLNMS station."
 | |
| 
 | |
|      ::=  {rndDeleteValuesEntry 1}
 | |
| 
 | |
| rndRowStatusObjectId OBJECT-TYPE
 | |
|    SYNTAX OBJECT IDENTIFIER
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The object id of the row status field. If the rndRowStatusVariableName is
 | |
|      a name present in the MIBs loaded into the MLNMS, this MIB
 | |
|      variable is not required, but if given, it must match the object id known
 | |
|      to the MLNMS.
 | |
|      The variable identified by rndRowStatusVariableName and/or rndRowStatusObjectId
 | |
|      must be a read-write MIB variable of type INTEGER which belongs to an
 | |
|      entry (i.e, is a child of a MIB variable of type SEQUENCE)."
 | |
| 
 | |
|      ::=  {rndDeleteValuesEntry 2}
 | |
| 
 | |
| rndRowDeleteValue OBJECT-TYPE
 | |
|    SYNTAX INTEGER
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The value of the variable identified by rndRowStatusVariableName and/or
 | |
|      rndRowStatusObjectId, which, if present in a SNMP SET PDU, will cause
 | |
|      the deletion of the conceptual row instance which the SET MIB variable
 | |
|      instance belongs."
 | |
|      ::=  {rndDeleteValuesEntry 3}
 | |
| 
 | |
| rndDeleteValueEntryStatus  OBJECT-TYPE
 | |
|    SYNTAX  RowStatus
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|          "It is used to delete an entry from this table."
 | |
|      ::=  {rndDeleteValuesEntry 4}
 | |
| 
 | |
| snmpTesting  OBJECT IDENTIFIER ::= { rndMidLevelManagement 9}
 | |
| 
 | |
| rndSimulatedVariablesTable  OBJECT-TYPE
 | |
|    SYNTAX SEQUENCE OF RndSimulatedVariablesEntry
 | |
|    MAX-ACCESS   not-accessible
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "This table indicates which MIB variables are simulated."
 | |
|     ::= {snmpTesting 1}
 | |
| 
 | |
| rndSimulatedVariablesEntry  OBJECT-TYPE
 | |
|    SYNTAX RndSimulatedVariablesEntry
 | |
|    MAX-ACCESS   not-accessible
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|        " The row definition for the rndSimulatedVariablesTable table."
 | |
|    INDEX { rndSimulatedVariableEntryIndex }
 | |
|     ::= {rndSimulatedVariablesTable 1}
 | |
| 
 | |
| RndSimulatedVariablesEntry ::= SEQUENCE {
 | |
| 
 | |
| rndSimulatedVariableEntryIndex  INTEGER,
 | |
| rndSimulatedVariableObjectId    OBJECT IDENTIFIER,
 | |
| rndNotSupportedField            INTEGER,
 | |
| rndSimulatedVariableEntryStatus RowStatus
 | |
| }
 | |
| 
 | |
| rndSimulatedVariableEntryIndex OBJECT-TYPE
 | |
|    SYNTAX INTEGER
 | |
|    MAX-ACCESS   read-only
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The index entry."
 | |
| 
 | |
|      ::=  {rndSimulatedVariablesEntry 1}
 | |
| 
 | |
| rndSimulatedVariableObjectId OBJECT-TYPE
 | |
|    SYNTAX OBJECT IDENTIFIER
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "The object id of the simulated variable. If the simulated variable belongs
 | |
|      to a table entry, the entire entry is henceforth supported."
 | |
| 
 | |
|      ::=  {rndSimulatedVariablesEntry 2}
 | |
| 
 | |
| rndNotSupportedField OBJECT-TYPE
 | |
|    SYNTAX INTEGER
 | |
|    MAX-ACCESS   read-only
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "Variable for not supported simulation."
 | |
|      ::=  {rndSimulatedVariablesEntry 3}
 | |
| 
 | |
| rndSimulatedVariableEntryStatus  OBJECT-TYPE
 | |
|    SYNTAX  RowStatus
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|          "It is used to delete an entry from this table."
 | |
|      ::=  {rndSimulatedVariablesEntry 4}
 | |
| 
 | |
| rndSnmpTestPassword  OBJECT-TYPE
 | |
|    SYNTAX INTEGER
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "This variable enables the user supplying the correct code to use the
 | |
|      SNMP test feature."
 | |
|     ::= {snmpTesting 2}
 | |
| 
 | |
| rndSnmpTests  OBJECT-TYPE
 | |
|    SYNTAX INTEGER {
 | |
|                    noSimulation(1),
 | |
|                    simulateSetFailure(2),
 | |
|                    simulateAppGet(3),
 | |
|                    simulateAppGetNext(4)
 | |
|                   }
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "This variable enables the authorized user to test various SNMP features."
 | |
|     ::= {snmpTesting 3}
 | |
| 
 | |
| rndSimulateUndo  OBJECT-TYPE
 | |
|    SYNTAX INTEGER
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "This variable enables the authorized user to test the SNMP UNDO feature."
 | |
|     ::= {snmpTesting 4}
 | |
| 
 | |
| rlSnmpServTestRequest  OBJECT-TYPE
 | |
|    SYNTAX INTEGER
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "This variable enables the authorized user to test the SNMP SERV package."
 | |
|     ::= {snmpTesting 5}
 | |
| 
 | |
| rlSnmpServTestResponse  OBJECT-TYPE
 | |
|    SYNTAX OCTET STRING
 | |
|    MAX-ACCESS   read-only
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "This variable enables the authorized user to retrieve the results of
 | |
|     a the SNMP SERV package test."
 | |
|    ::= {snmpTesting 6}
 | |
| 
 | |
| rlSnmpServCreateTestPool  OBJECT-TYPE
 | |
|    SYNTAX INTEGER { create(1), no-create(2) }
 | |
|    MAX-ACCESS   read-write
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "This variable enables the authorized user to indicate that after its reset
 | |
|      the device should create a buffer pool for SNMPServ process PDU
 | |
|      testing."
 | |
|    ::= {snmpTesting 7}
 | |
| 
 | |
| rlSnmpServITCbindClients  OBJECT-TYPE
 | |
|     SYNTAX OBJECT IDENTIFIER
 | |
|     MAX-ACCESS  read-write
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "This variable enables the authorized user to to indicate that after
 | |
|          its reset the device should create ITC clients for SnmpServ data
 | |
|          requests clients.
 | |
|          The semantics of this variable is as follows:
 | |
|             subidentifier 2*n indicates whether the client n is synchronous(1) or
 | |
|             asynchronous(2)
 | |
|             subidentifier 2*n+1 indicates the number of simulatneous requests
 | |
|             expected by client n."
 | |
|     ::= {snmpTesting 8}
 | |
| 
 | |
| rlSnmpTestSimulatedVariables  OBJECT IDENTIFIER ::= {snmpTesting 9}
 | |
| 
 | |
| rlTstBasicRateTable OBJECT-TYPE
 | |
|     SYNTAX SEQUENCE OF RlTstBasicRateEntry
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "Table for testing SNMP agent."
 | |
|     ::= { snmpTesting 10 }
 | |
| 
 | |
| rlTstBasicRateEntry OBJECT-TYPE
 | |
|     SYNTAX RlTstBasicRateEntry
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "An entry in the rlTstBasicRateTable."
 | |
|     INDEX { ifIndex }
 | |
|     ::= { rlTstBasicRateTable 1 }
 | |
| 
 | |
| RlTstBasicRateEntry ::= SEQUENCE {
 | |
|     rlTstBasicRateIfType INTEGER,
 | |
|     rlTstBasicRateLineTopology INTEGER,
 | |
|     rlTstBasicRateIfMode INTEGER,
 | |
|     rlTstBasicRateSignalMode INTEGER
 | |
|     }
 | |
| 
 | |
| rlTstBasicRateIfType OBJECT-TYPE
 | |
|     SYNTAX INTEGER {
 | |
|         isdns(75),
 | |
|         isdnu(76)
 | |
|         }
 | |
|     MAX-ACCESS  read-write
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         ""
 | |
|     ::= { rlTstBasicRateEntry 1 }
 | |
| 
 | |
| rlTstBasicRateLineTopology OBJECT-TYPE
 | |
|     SYNTAX INTEGER {
 | |
|         pointToPoint(1),
 | |
|         pointToMultipoint(2)
 | |
|         }
 | |
|     MAX-ACCESS  read-write
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         ""
 | |
|     ::= { rlTstBasicRateEntry 2 }
 | |
| 
 | |
| rlTstBasicRateIfMode OBJECT-TYPE
 | |
|     SYNTAX INTEGER {
 | |
|         te(1),
 | |
|         nt(2)
 | |
|         }
 | |
|     MAX-ACCESS  read-write
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         ""
 | |
|     ::= { rlTstBasicRateEntry 3 }
 | |
| 
 | |
| rlTstBasicRateSignalMode OBJECT-TYPE
 | |
|     SYNTAX INTEGER {
 | |
|         active(1),
 | |
|         inactive(2)
 | |
|         }
 | |
|     MAX-ACCESS  read-write
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         ""
 | |
|     ::= { rlTstBasicRateEntry 4 }
 | |
| 
 | |
| rlMibTree OBJECT IDENTIFIER ::= {rndMidLevelManagement 10 }
 | |
| 
 | |
| rlMibTreeTable OBJECT-TYPE
 | |
|    SYNTAX SEQUENCE OF RlMibTreeEntry
 | |
|    MAX-ACCESS   not-accessible
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|     "This reflects the MIB tree of the device."
 | |
|    ::= {rlMibTree 1 }
 | |
| 
 | |
| 
 | |
| rlMibTreeEntry OBJECT-TYPE
 | |
|    SYNTAX RlMibTreeEntry
 | |
|    MAX-ACCESS   not-accessible
 | |
|    STATUS       current
 | |
|    DESCRIPTION
 | |
|        " Each row shows a tree relationsship in the MIB."
 | |
|    INDEX { rlMibTreeFather, rlMibTreeSonIndex }
 | |
|    ::= {rlMibTreeTable 1 }
 | |
| 
 | |
|    RlMibTreeEntry ::= SEQUENCE {
 | |
| 
 | |
|      rlMibTreeFather                 DisplayString,
 | |
|      rlMibTreeSonIndex               INTEGER,
 | |
|      rlMibTreeSon                    DisplayString,
 | |
|      rlMibTreeSonObjectId            OBJECT IDENTIFIER,
 | |
|      rlMibTreeGrandFather            DisplayString
 | |
| }
 | |
| 
 | |
| 
 | |
|  rlMibTreeFather OBJECT-TYPE
 | |
|      SYNTAX DisplayString
 | |
|      MAX-ACCESS         not-accessible
 | |
|      STATUS     current
 | |
|      DESCRIPTION
 | |
|        " The father in a tree relation ship."
 | |
|      ::= {rlMibTreeEntry 1 }
 | |
| 
 | |
|  rlMibTreeSonIndex OBJECT-TYPE
 | |
|      SYNTAX INTEGER
 | |
|      MAX-ACCESS         not-accessible
 | |
|      STATUS     current
 | |
|      DESCRIPTION
 | |
|        " Running index for this table."
 | |
|      ::= {rlMibTreeEntry 2 }
 | |
| 
 | |
|  rlMibTreeSon OBJECT-TYPE
 | |
|      SYNTAX DisplayString
 | |
|      MAX-ACCESS         read-only
 | |
|      STATUS     current
 | |
|      DESCRIPTION
 | |
|        " The son in a tree relation ship."
 | |
|      ::= {rlMibTreeEntry 3 }
 | |
| 
 | |
|  rlMibTreeSonObjectId OBJECT-TYPE
 | |
|      SYNTAX OBJECT IDENTIFIER
 | |
|      MAX-ACCESS         read-only
 | |
|      STATUS     current
 | |
|      DESCRIPTION
 | |
|        " The object identifier of the son in a tree relation ship."
 | |
|      ::= {rlMibTreeEntry 4}
 | |
| 
 | |
|  rlMibTreeGrandFather OBJECT-TYPE
 | |
|      SYNTAX DisplayString
 | |
|      MAX-ACCESS         read-only
 | |
|      STATUS     current
 | |
|      DESCRIPTION
 | |
|        " The grand father (i.e father's father) in a tree relation ship."
 | |
|      ::= {rlMibTreeEntry 5 }
 | |
| 
 | |
| 
 | |
| -- Obsolete
 | |
| -- rsIpZeroHopRouting  OBJECT IDENTIFIER ::= { rndApplications 3}
 | |
| 
 | |
| 
 | |
| rsPingMIB OBJECT IDENTIFIER ::= { rndApplications 4} -- NEW Group
 | |
| rsPingTable OBJECT-TYPE
 | |
|     SYNTAX SEQUENCE OF RsPingEntry
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "A table of ping request entries."
 | |
|     ::= { rsPingMIB 1 }
 | |
| 
 | |
| rsPingEntry OBJECT-TYPE
 | |
|     SYNTAX RsPingEntry
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "A ping request entry.
 | |
| 
 | |
|         A management station wishing to create an entry should
 | |
|         first generate a pseudo-random serial number to be used
 | |
|         as the index to this sparse table. It must also create in the same
 | |
|         PDU the associated instance of the address object. It should also
 | |
|         modify in the same PDU the default values for the other configuration
 | |
|         objects if the defaults are not appropriate.
 | |
| 
 | |
|         Once the sequence completes, the management station should
 | |
|         retrieve the values of the status objects of interest, and
 | |
|         should then delete the entry.  In order to prevent old
 | |
|         entries from clogging the table, entries will be aged out,
 | |
|         but an entry will never be deleted within 5 minutes of
 | |
|         completing."
 | |
|     INDEX { rsPingAddress }
 | |
|     ::= { rsPingTable 1 }
 | |
| 
 | |
| RsPingEntry ::= SEQUENCE {
 | |
|     rsPingAddress          IpAddress,
 | |
|     rsPingPacketCount      INTEGER,
 | |
|     rsPingPacketSize       INTEGER,
 | |
|     rsPingPacketTimeout    INTEGER,
 | |
|     rsPingDelay            INTEGER,
 | |
|     rsPingTrapOnCompletion TruthValue,
 | |
|     rsPingSentPackets      Counter32,
 | |
|     rsPingReceivedPackets  Counter32,
 | |
|     rsPingMinReturnTime    INTEGER,
 | |
|     rsPingAvgReturnTime    INTEGER,
 | |
|     rsPingMaxReturnTime    INTEGER,
 | |
|     rsPingCompletionStatus INTEGER,
 | |
|     rsPingTimeStamp        DisplayString,
 | |
|     rsPingEntryStatus      RowStatus
 | |
|     }
 | |
| 
 | |
| rsPingAddress OBJECT-TYPE
 | |
|     SYNTAX IpAddress
 | |
| --    Rsyntax OCTET STRING
 | |
|     MAX-ACCESS  read-write
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The address of the device to be pinged.
 | |
|          Once an instance of this object is created, its
 | |
|          value can not be changed."
 | |
|     ::= { rsPingEntry 1 }
 | |
| 
 | |
| rsPingPacketCount OBJECT-TYPE
 | |
|     SYNTAX INTEGER(1..2147483647)
 | |
|     MAX-ACCESS  read-write
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "Specifies the number of ping packets to send to the target
 | |
|         in this sequence."
 | |
| --    DEFVAL { 5 }
 | |
|     ::= { rsPingEntry 2 }
 | |
| 
 | |
|  rsPingPacketSize OBJECT-TYPE
 | |
|     SYNTAX INTEGER
 | |
|     MAX-ACCESS  read-write
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "Specifies the size of ping packets to send to the target
 | |
|         in this sequence.  The lower and upper boundaries of this
 | |
|         object are implementation dependent."
 | |
| --    DEFVAL { 100 }
 | |
|     ::= { rsPingEntry 3 }
 | |
| 
 | |
| rsPingPacketTimeout OBJECT-TYPE
 | |
|     SYNTAX INTEGER(0..3600000)
 | |
| --  Units
 | |
| --    milliseconds
 | |
|     MAX-ACCESS  read-write
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "Specifies the amount of time to wait for a response to a
 | |
|         transmitted packet before declaring the packet 'dropped.'"
 | |
| --    DEFVAL { 2000 }
 | |
|     ::= { rsPingEntry 4 }
 | |
| 
 | |
| rsPingDelay OBJECT-TYPE
 | |
|     SYNTAX INTEGER(0..3600000)
 | |
| --  Units
 | |
| --    milliseconds
 | |
|     MAX-ACCESS  read-write
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|        "Specifies the minimum amount of time to wait before sending
 | |
|         the next packet in a sequence after receiving a response.
 | |
|         The actual delay may be greater due to internal task scheduling."
 | |
| --    DEFVAL { 0 }
 | |
|     ::= { rsPingEntry 5 }
 | |
| 
 | |
| rsPingTrapOnCompletion OBJECT-TYPE
 | |
|     SYNTAX TruthValue
 | |
|     MAX-ACCESS  read-write
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "Specifies whether or not a rsPingCompletion trap should
 | |
|          be issued on completion of the sequence of pings.  If such a
 | |
|          trap is desired, the NMS should ensure that the community table
 | |
|          contains an instance specified by the NMSs IP address with
 | |
|          rndCommunityTrapsEnable = trapsEnable."
 | |
| --  DEFVAL { false }
 | |
|     ::= { rsPingEntry 6 }
 | |
| 
 | |
| rsPingSentPackets OBJECT-TYPE
 | |
|     SYNTAX Counter32
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The number of ping packets that have been sent to the target
 | |
|         in this sequence."
 | |
|     ::= { rsPingEntry 7 }
 | |
| 
 | |
| rsPingReceivedPackets OBJECT-TYPE
 | |
|     SYNTAX Counter32
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The number of ping packets that have been received from the
 | |
|         target in this sequence."
 | |
|     ::= { rsPingEntry 8 }
 | |
| 
 | |
| rsPingMinReturnTime OBJECT-TYPE
 | |
|     SYNTAX INTEGER
 | |
| --  Units
 | |
| --    milliseconds
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The minimum round trip time of all the packets that have
 | |
|          been sent in this sequence. The value returned to a GET request
 | |
|          is meaningless if no ping response in a sequence has been received
 | |
|          yet."
 | |
|     ::= { rsPingEntry 9 }
 | |
| 
 | |
| rsPingAvgReturnTime OBJECT-TYPE
 | |
|     SYNTAX INTEGER
 | |
| --  Units
 | |
| --    milliseconds
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The average round trip time of all the packets that have
 | |
|          been sent in this sequence.The value returned to a GET request
 | |
|          is meaningless if no ping response in a sequence has been received
 | |
|          yet."
 | |
|     ::= { rsPingEntry 10 }
 | |
| 
 | |
| rsPingMaxReturnTime OBJECT-TYPE
 | |
|     SYNTAX INTEGER
 | |
| --  Units
 | |
| --    milliseconds
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The maximum round trip time of all the packets that have
 | |
|          been sent in this sequence.The value returned to a GET request
 | |
|          is meaningless if no ping response in a sequence has been received
 | |
|          yet."
 | |
|     ::= { rsPingEntry 11 }
 | |
| 
 | |
| rsPingCompletionStatus OBJECT-TYPE
 | |
|     SYNTAX INTEGER {
 | |
|        ok(1),
 | |
|        timeout(2),
 | |
|        net-unreachable(3),
 | |
|        host-unreachable(4),
 | |
|        protocol-unreachable(5),
 | |
|        time-to-live-exceeded(6),
 | |
|        reassembly-time-exceeded(7),
 | |
|        unable-to-send(8),
 | |
|        bad-reply-data(9),
 | |
|        incomplete(10)
 | |
|        }
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "If all the echo request packets in this sequence have been
 | |
|          responded by valid echo responses, this object is set to ok.
 | |
|          Otherwise this status indicates the problem. bad-reply-data indicates
 | |
|          that the reply data is not equal to the response data."
 | |
|     ::= { rsPingEntry 12 }
 | |
| 
 | |
| rsPingTimeStamp OBJECT-TYPE
 | |
|     SYNTAX DisplayString(SIZE(19))
 | |
|     MAX-ACCESS  read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The time-stamp indicating the time and date of creation or last
 | |
|          update of this request. The format of the time-stamp is
 | |
|          dd/mm/yyyy hh:mm:ss"
 | |
|     ::= { rsPingEntry 13 }
 | |
| 
 | |
| 
 | |
| rsPingEntryStatus OBJECT-TYPE
 | |
|     SYNTAX RowStatus
 | |
|     MAX-ACCESS  read-write
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The status of this table entry."
 | |
|     ::= { rsPingEntry 14 }
 | |
| 
 | |
| rsPowerSupplyRedundacy OBJECT IDENTIFIER ::= { rndApplications 5} -- NEW Group
 | |
| rsPowerSupplyRedundacyTable   OBJECT-TYPE
 | |
|     SYNTAX SEQUENCE OF RsPowerSupplyRedundacyEntry
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The power supply redundancy table."
 | |
|     ::=  { rsPowerSupplyRedundacy 1  }
 | |
| 
 | |
| rsPowerSupplyRedundacyEntry OBJECT-TYPE
 | |
|     SYNTAX RsPowerSupplyRedundacyEntry
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The status of power supply redundancy for this table."
 | |
|     INDEX { rsPowerSupplyRedundacyReNumber}
 | |
|     ::= { rsPowerSupplyRedundacyTable 1}
 | |
| 
 | |
| RsPowerSupplyRedundacyEntry ::= SEQUENCE {
 | |
|     rsPowerSupplyRedundacyReNumber       INTEGER,
 | |
|     rsPowerSupplyRedundacyStatus         INTEGER
 | |
|     }
 | |
| 
 | |
| rsPowerSupplyRedundacyReNumber OBJECT-TYPE
 | |
|     SYNTAX INTEGER  (1..31)
 | |
|     MAX-ACCESS          read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "This number identifies the module backed up
 | |
|          by power supply redundancy in the stack."
 | |
|     ::= { rsPowerSupplyRedundacyEntry 1}
 | |
| 
 | |
| rsPowerSupplyRedundacyStatus OBJECT-TYPE
 | |
|     SYNTAX INTEGER{
 | |
|         notExist(1),
 | |
|         existButNotWorking(2),
 | |
|         bothWorking(3),
 | |
|         internalOnlyWorking(4),
 | |
|         externalOnlyWorking(5)
 | |
|         }
 | |
|     MAX-ACCESS          read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The status of a power supply redundancy of the entry."
 | |
|     ::= { rsPowerSupplyRedundacyEntry 2}
 | |
| 
 | |
| rsNvram  OBJECT IDENTIFIER ::= { rndApplications 6 }
 | |
| rsEraseNvramAfterReset OBJECT-TYPE
 | |
|     SYNTAX DisplayString  (SIZE(0..20))
 | |
|     MAX-ACCESS          read-write
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The name of NVRAM application that will be erased
 | |
|          after reset or ALL if all NVRAM should be erased."
 | |
|     ::=  { rsNvram 1 }
 | |
| 
 | |
| rsNvramApplTable   OBJECT-TYPE
 | |
|     SYNTAX SEQUENCE OF RsNvramApplEntry
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The NVRAM application table."
 | |
|     ::=  { rsNvram 2 }
 | |
| 
 | |
| rsNvramApplEntry OBJECT-TYPE
 | |
|     SYNTAX RsNvramApplEntry
 | |
|     MAX-ACCESS  not-accessible
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The status of NVRAM application table."
 | |
|     INDEX { rsNvramApplIndex}
 | |
|     ::= { rsNvramApplTable 1}
 | |
| 
 | |
| RsNvramApplEntry ::= SEQUENCE {
 | |
|     rsNvramApplIndex       INTEGER,
 | |
|     rsNvramApplName        DisplayString
 | |
|     }
 | |
| 
 | |
| rsNvramApplIndex OBJECT-TYPE
 | |
|     SYNTAX INTEGER
 | |
|     MAX-ACCESS          read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The index of NVRAM application table."
 | |
|     ::= { rsNvramApplEntry 1}
 | |
| 
 | |
| rsNvramApplName OBJECT-TYPE
 | |
|     SYNTAX DisplayString  (SIZE(0..20))
 | |
|     MAX-ACCESS          read-only
 | |
|     STATUS      current
 | |
|     DESCRIPTION
 | |
|         "The name of application used NVRAM."
 | |
|     ::= { rsNvramApplEntry 2}
 | |
| 
 | |
| END
 | |
| 
 |